Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Jul 2024
Closing Date24 Sep 2024
Tender Amount₹ 48,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L concealed point wiring for One light point/Ceiling fan/Exhaut fan/bell point controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed. Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. (ii) Where concealing of conduit is not feasible i.e. on surface of RCC roof slab, beam etc, conduit shall be fixed on surface with necessary saddles at no extra cost.

60

-

-

... More
All as per item No 4 here-in-above but One socket out let 5/6 amps point on the same board

15

-

-

... More
All as per item No 4 here-in-above but One socket out let 5/6 amps point on the independent board

20

-

-

... More
All as per item No 4 here-in-above but One Light point controlled by two numbers two way switches 5/6 Amps.

5

-

-

... More
M&L concealed point wiring for One one socket outlet 15 Amps point on independent board point controlled by one way switch 15/16 amps complete with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed. Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. (ii) Where concealing of conduit is not feasible i.e. on surface of RCC roof slab, beam etc, conduit shall be fixed on surface with necessary saddles at no extra cost.

15

-

-

... More
M&L surface point wiring for light/fan/bell, buzzer points controlled by one, one way switch complete controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing capping medium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed. Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles.

250

-

-

... More
All as per item No 9 here-in-above but One socket out let 5/6 amps point on the same board

100

-

-

... More
All as per item No 9 here-in-above but One socket out let 5/6 amps point on the independent board

70

-

-

... More
All as per item No 9 here-in-above but One Light point controlled by two numbers two way switches 5/6 Amps.

20

-

-

... More
M&L surface point wiring for One socket outlet 15 Amps point on independent board point controlled by one way switch 15/16 amps complete with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing capping medium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed. Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles.

40

-

-

... More
M&L Concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED

40

-

-

... More
M&L Concealed sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED

50

-

-

... More
M&L Surface type sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing capping medium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED

80

-

-

... More
M&L Surface type sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing capping medium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED

220

-

-

... More
S&F Switch piano, flush type single pole, one way 5/6 Amp complete all as specified and as directed.

300

-

-

... More
Fixing only Switch piano,flush type single pole, one way 5/6 Amp complete all as specified and as directed. Note:- Serviceable Piano Switch obtained from Item No 1 here-in-before

30

-

-

... More
S&F Switch piano, flush type single pole, two way 5/6 Amp complete all as specified and as directed.

20

-

-

... More
S&F Bell push, flush type, 5/6 amps, flush type complete all as specified and as directed.

40

-

-

... More
S&F Switch Socket outlet 2 in 1, 3 pin, 5/6 Amps flush type complete all as specified and as directed.

120

-

-

... More
Fixing only Socket any type 5/6 Amp complete all as specified and as directed. Note:- Serviceable Socket obtained from Item No 1 here-in-before

20

-

-

... More
S&F Switch socket combination 2 in 1, 3 pin, 5/6 Amp flush type universal complete all as specified and as directed.

60

-

-

... More
Fixing only Switch socket combination 2 in 1, 3 pin, 5/6 Amp complete all as specified and as directed. Note:- Serviceable Socket obtained from Item No 1 here-in-before

10

-

-

... More
S&F Switch socket combination 2 in 1, 3 pin, 15/16 Amp flush type universal complete all as specified and as directed.

60

-

-

... More
Fixing only Switch socket combination 2 in 1, 3 pin, 15/16 Amp complete all as specified and as directed. Note:- Serviceable Socket obtained from Item No 1 here-in-before

20

-

-

... More
S&F Socket, flush type, single pole, one way, 15/16 Amps complete all as specified and as directed.

25

-

-

... More
S&F swithch, flush type, single pole, one way, 15/16 Amps complete all as specified and as directed

25

-

-

... More
S&F ceiling rose, 3 phase PVC/ polycarbonate, insulated body, three terminals, complete all as specified and as directed

40

-

-

... More
Fixing only ceiling rose any type complete all as specified and as directed. Note:- Serviceable Ceiling Rose obtained from Item No 1 here-in-before

10

-

-

... More
S&F step type electronic fan regulator flush type (05 steps) complete all as specified and as directed.

60

-

-

... More
Fixing only fan regulator any type complete all as specified and as directed. Note:- Serviceable regulators obtained from Item No 1 here-in-before

10

-

-

... More
S&F lamp holder, insulated PVC/ Polycarbonate body, with back plate suitable for batten/angle fittings complete all as specified and directed.

300

-

-

... More
Fixing only lamp holder, any type complete all as specified and as directed. Note:- Serviceable lamp holder, obtained from Item No 1 here-in-before

20

-

-

... More
S&F Call Bell, suitable for 230 Volts complete all as specified and as directed.

50

-

-

... More
S&F LED bulb 10 watt 5 STAR LAMP with B 22 base capacity 1200 lumen complete all as specified.

300

-

-

... More
S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), IP-43 double door, Single pole & neutral with 200 Amps rated bus bar, 240 Volts,IP-43 protection, complete including. blanking plates as required & flush to wall/other surface complete all as specified and as directed

7

-

-

... More
S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 double door, Single pole & neutral with 200 Amps rated bus bar,240 Volts, IP-43 protection, complete including. blanking plates as required & flush to wall/other surface complete all as specified and as directed

5

-

-

... More
S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 double door, Triple pole & neutral with 200 Amps rated bus bar,240 Volts, IP-43 protection, complete including. blanking plates as required & flush to wall/other surface complete all as specified and as directed

3

-

-

... More
S&F MCB, TPN, C Series 415 Volts, 63 Amps 50 HZ, 10KA complete all as specified and as directed.

15

-

-

... More
S&F MCB, SPN, C Series 240 Volts, 40 Amps 50 HZ, 10KA complete all as specified and as directed.

45

-

-

... More
S&F MCB, SP, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed.

80

-

-

... More
S&F LED luminarie tube light fitting basic all purpose surface/wall mounted decrotative slim with polycarbonate housing & integrated electronic driver, 4 feet LED with high efficient LEDs 20 watt, (or nearest next higher wattage) with all accessories, suitable for operation on AC, single phase 220/230 Volts, 50 Hz, 6500K complete all as specified and as directed.

450

-

-

... More
S&F energy saving & environment friendly long life 20 Watt,(or nearest next higher wattage) CT ≥ 6500 K, LED building security light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-07 complete with integrated type, with high efficiency electronic driver, surge suppressor of 5 KV or more & high brightness LEDs, luminaire efficacy 110 lumens/Watt, power factor ≥ 0.90, operating range 140 to 270 V, 50 Hz complete including GI pipe bracket of adequate size as required (Light Grade) of length 1.2 mtrs bent to shape and fixed with 40mm x 5mm MS flat with necessary nuts, bolts, washers etc, painting with two coats of syntheic enamel paint over a coat of primer and connecting up with and including three core twisted flexible copper conductor cable of suitable size all as specified & as directed.

30

-

-

... More
S&F LED luminarie tube light fitting basic all purpose surface/wall mounted 2 feet LED batton with polycarbonate housing & integrated electronic driver, with high efficient LEDs 9 watt, (or next nearer higher watt) with all accessories, suitable for operation on Ac, single phase 220 / 230 Volts, 50 Hz supply, complete all as specified and as directed.

30

-

-

... More
S&F in repair, LED bulb 10 watt 5 STAR LAMP with B 22 base capacity 1200 lumen complete all as specified.

40

-

-

... More
S&F Bulk head LED fitting with injection molded Polycarbonate housing suitable for 10 Watt (or nearest next higher wattage) with IP 66 protection & impact resistance not less than IK-10 complete with integrated type, with high efficiency electronic driver, & high brightness LEDs, luminaire efficacy 100 lumens/Watt, power factor ≥ 0.95, operating range 140 to 270 V, 50 and connecting complete all as specified and as directed.

30

-

-

... More
S&F in repair, ceiling fan capacitor 2.25 mfd as per site requirement heavy duty with metal body complete all as specified and directed.

40

-

-

... More
S&F in repair, ceiling fan capacitor 2.5 mfd as per site requirement heavy duty with metal body complete all as specified and directed.

130

-

-

... More
S&F in repair, ceiling fan capacitor 3.15 mfd as per site requirement heavy duty with metal body complete all as specified and directed.

30

-

-

... More
S&F in repair, ceiling fan capacitor 4 mfd as per site requirement heavy duty with metal body complete all as specified and directed.

15

-

-

... More
S&F in repair, ceiling fan capacitor 6 mfd as per site requirement heavy duty with metal body complete all as specified and directed.

10

-

-

... More
Taking up the existing unservicable UG cable of any type/ description as existing at site complete all as directed Note : Earthwork will be measured and paid seperately.

850

-

-

... More
Relaying Serviceable LT UG XLPE cable of size 3.5 core x 35/50 sq mm obtained from item no. 53 laid in trenches/ floors/ on wall/ service connections after cutting and jointing through Cable Joint kit as per site requirement including connecting to the main switches/ cut outs MCB/ MCCB with necessary lugs after cutting to required length of cable all as specified and directed.

50

-

-

... More
Relaying Serviceable LT UG XLPE cable of size 3.5 core x 16/25 sq mm obtained from item no. 53 laid in trenches/ floors/ on wall/ service connections after cutting and jointing through Cable Joint kit as per site requirement including connecting to the main switches/ cut outs MCB/ MCCB with necessary lugs after cutting to required length of cable all as specified and directed.

50

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.

200

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.

200

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.

150

-

-

... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc laying of cables etc and getting out in soft/loose soil complete all as specified and as directed.

162

-

-

... More
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.

108

-

-

... More
Removing excavated material n.exc 50m and depositing were directed at a level not exceeding 1.5m above the starting level complete all as specified and as directed.

54

-

-

... More
M&L sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed.

48.6

-

-

... More
Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed.

4800

-

-

... More
M&L for 40mm bore GI pipe light grade with all necessary fittings (ISI marked) as in cable protection fixed to pole, laid in trenches/road/floor complete all as specified and as directed.

36

-

-

... More
S&F in repair PVC square box 100mm x 100mm including refixing of old switch socket complete all as specified and as directed.

50

-

-

... More
S&F in repair PVC square box 170mm x 100mm including refixing of old switch socket complete all as specified and as directed.

50

-

-

... More
S&F in repair PVC square box 200mm x 150mm including refixing of old switch socket complete all as specified and as directed.

50

-

-

... More
S&F in repair PVC square box 300mm x 250mm including refixing of old switch socket complete all as specified and as directed.

15

-

-

... More
S&F in repair laminated sheet of size 12" x 12" complete all as directed.

70

-

-

... More
S&F in repair 25x16mm, medium grade, PVC casing and capping duly fixed with casing pins and connecting accessories like Tee , Bends , elbow etc required as per site complete all as direced.

500

-

-

... More
S&F in repair 25mm dia medium grade PVC Conduit duly fixed with Clamps on wall surfaces and connecting accessories like Tee , Bends , elbow etc required as per site complete all as direced.

90

-

-

... More
M&L earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to depth not less than 2.25m below the ground level with top edge of earth plate at a depth not less than 1.5m below the ground level connected to galvanized iron wire 4mm dia earth lead by means of bolts & nuts,check nuts & washers made of galvanised steel, earth wire protected by and including PCC (1:2:4) type B1 precast RCC cover slab (1:2:4, type B1)reinforced with 8mm dia TMT bars 100mm center to center bothways including one handle made of 10 mm dia round bar, including necessary excavation and earthwork in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth wire GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion including dismantling/taking out old unserviceable earthing complete all as specified and as directed.

8

-

-

... More
Refixing surface point wiring for light/fan/bell, buzzer points controlled by one, one way switch complete controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed cable 1100 volts grade with proper colour coding drawn through and including non-metallic rigid PVC casing capping medium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed. Notes:- (i) Serviceable wire and suken terminal box made out of MS sheet steel for boxes obtained from item No. 1 here-in-before shall be reused (ii) Cost of PVC casing capping with accessories is deemed to inclusive in Unit rate Quoted (iii) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles.

20

-

-

... More
All as per item No 74 here-in-above but One socket out let 5/6 amps point on the same board

10

-

-

... More
All as per item No 74 here-in-above but One socket out let 5/6 amps point on the independent board

10

-

-

... More
Description all as per item No 74 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 2.5 sqmm multi stranded copper conductor as continuous earth wire with lugs complete all as specified and directed.

10

-

-

... More
Fixing only Sheet metal enclosure for 4/6/8/12 way Distribution Boards (DB’s), double door, Single pole & neutral with 200 Amps rated bus bar, 240 Volts,IP-43 protection, complete including. blanking plates as required & flush to wall/other surface complete all as specified and as directed Note:- Serviceable SPN DB;s obtained from item No. 2 here-in-before shall fixed

2

-

-

... More
Fixing only Sheet metal enclosure for 4/6/8/12 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 Amps rated bus bar, 414 Volts,IP-43 protection, complete including. blanking plates as required & flush to wall/other surface complete all as specified and as directed Note:- Serviceable TPN DB;s obtained from item No. 2 here-in-before shall fixed

3

-

-

... More
Fixing only MCB, FP, 63 Amps complete all as specified and as directed Note:- Serviceable MCB;s obtained from item No. 2 here-in-before shall fixed

3

-

-

... More
Fixing only MCB, SPN, 6-32 Amps complete all as specified and as directed Note:- Serviceable MCB;s obtained from item No. 2 here-in-before shall fixed

5

-

-

... More
Fixing only MCB, SP, 32 Amps complete all as specified and as directed Note:- Serviceable MCB;s obtained from item No. 2 here-in-before shall fixed

15

-

-

... More
Fixing only Earth and Plug socket with MCB of any rating and flush to wall/other surface complete all as specified and as directed Note:- Serviceable Earth Plug obtained from item No. 2 here-in-before shall fixed

2

-

-

... More
Refixing Surface type sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire,PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing capping medium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i) Serviceable wire and obtained from item No.3 here-in-before shall be reused (ii) Cost of PVC casing capping with accessories is deemed to inclusive in Unit rate Quoted (iii) Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (iv) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED

25

-

-

... More
Refixing Surface type sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire,PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing capping medium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i) Serviceable wire and obtained from item No.3 here-in-before shall be reused (ii) Cost of PVC casing capping with accessories is deemed to inclusive in Unit rate Quoted (iii) Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (iv) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED

20

-

-

... More
Fixing only LED luminarie, of any wattage complete all as directed Note:- Serviceable Light fittings obtained from item No. 1 here-in-before shall fixed

20

-

-

... More
Taking down and Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as directed

20

-

-

... More
Taking down and Fixing only exhaust fan and connecting up including provision of cable from ceiling rose/ connector to fan complete all as directed

20

-

-

... More
S&F in repair PVC insulated sheathed multicore cable copper conductor 1.00 Sqmm, 2 Core complete all as specified and as directed

200

-

-

... More
S&F in repair PVC insulated sheathed multicore cable copper conductor 1.50 Sqmm, 3 Core complete all as specified and as directed

200

-

-

... More
S&F in repair PVC insulated sheathed multicore cable copper conductor 2.50 Sqmm, 3 Core complete all as specified and as directed

200

-

-

... More
S&F in repair, round slim surface mounted LED luminarie 12 Watt, (or next nearer higher watt) 6500K with diffuser to ensure glare free and even light distribution & integrated electronic driver, with all accessories, suitable for operation on AC, single phase 220 / 230 Volts, 50 Hz supply, complete all as specified and as directed.

10

-

-

... More
S&F in repair, 600mm x 600mm ultra slim recessed mounted LED module with high brightness, de-glaring PP diffuser and PS LGP de-glaring sheet for glare free uniform light distribution suitable for grid ceiling LED luminarie 40 Watt, (or next nearer higher watt) 6500K with diffuser to ensure glare free and even light distribution & integrated electronic driver, with all accessories, suitable for operation on Ac, single phase 220 / 230 Volts, 50 Hz supply, complete all as specified and as directed.

20

-

-

... More
S&F in repair Modular Switch 1 way 6 Amps, 1 module, complete all as specified and directed.

30

-

-

... More
S&F in repair Modular Switch 1 way 16 Amps, 1 module, complete all as specified and directed.

10

-

-

... More
S&F in repair Modular Socket 6 Amps, 5 pin, 2 module, complete all as specified and directed.

10

-

-

... More
S&F in repair Modular Socket 6 A/ 16 Amps, 6 pin combined 2, complete all as specified and directed.

10

-

-

... More
S&F in repair Modular Bell Push Switch 1 way 6 Amps, 1 module, complete all as specified and directed.

2

-

-

... More
S&F in repair Modular Blank plate, 1 module, complete all as specified and directed.

5

-

-

... More
S&F in repair Modular type White cover plate with frame 1 module, complete all as specified and directed.

3

-

-

... More
S&F in repair Modular type White cover plate with frame 3 module, complete all as specified and directed.

8

-

-

... More
S&F in repair Modular type White cover plate with frame 4 module, complete all as specified and directed.

4

-

-

... More
S&F in repair Modular type White cover plate with frame 8 module, complete all as specified and directed.

6

-

-

... More
S&F in repair Modular type White cover plate with frame 12 module, complete all as specified and directed.

3

-

-

... More
S&F in repair Modular type Metal Flush box 1 module, complete all as specified and directed.

3

-

-

... More
S&F in repair in repair Modular type Metal Flush box 3 module, complete all as specified and directed.

8

-

-

... More
S&F in repair Modular type Metal Flush box 4 module, complete all as specified and directed.

4

-

-

... More
S&F in repair Modular type Metal Flush box 8 module, complete all as specified and directed.

6

-

-

... More
S&F in repair Modular type Metal Flush box 12 module, complete all as specified and directed.

3

-

-

... More
S&F in repair, VTPN DB, 08 Way, double door,Metal door ,IP-43 IK 09, with MCCB as(upto 125Amps) incomer, and MCB;s as Outgoing , 250Amps rated copper bus bars,earth bar,neutral links, no. of module complete including blanking plates as required & fixed flush to wall and making good the disturbed surfaces including complete all as specified and as directed. Note:- MCCB;s/MCB's required as Outgoing shall be measured and pair seperately under appropiate items

1

-

-

... More
S&F in repair, MCCB 4P, 125 Amps,thermal magnetic release, 415V ,50 Hz ,breaking capacity 25 KA complete all as specified and as directed.

2

-

-

... More
S&F in repair, MCCB 4P, 100 Amps,thermal magnetic release, 415V ,50 Hz ,breaking capacity 25 KA complete all as specified and as directed.

2

-

-

... More
S&F in repair, Single Pole and Neutral encloser with two pin and earth plug and socket with one SP MCB 20 Amps complete all as specified and as directed.

5

-

-

... More
M&L Concealed sub-main wiring alongwith earth wire of size of 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED

20

-

-

... More
M&L Concealed sub-main wiring alongwith earth wire of size of 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED

30

-

-

... More
M&L Surface type sub-main wiring alongwith earth wire of size of 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing capping medium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED

40

-

-

... More
M&L Surface type sub-main wiring alongwith earth wire of size of 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing capping medium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED

40

-

-

... More
S&F in repair, LED luminarie tube light fitting basic all purpose surface/ wall mounted decrotative slim with polycarbonate housing & integrated electronic driver, 4 feet LED with high efficient LEDs 20 watt, (or nearest next higher wattage) with all accessories, suitable for operation on AC, single phase 220/230 Volts, 50 Hz, 3000K complete all as specified and as directed.

5

-

-

... More
S&F in repair, energy saving & environment friendly long life 35/36 Watt,(or nearest next higher wattage) CT ≥ 6500 K, LED building security light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-07 complete with integrated type, with high efficiency electronic driver, surge suppressor of 5 KV or more & high brightness LEDs, luminaire efficacy 110 lumens/Watt, power factor ≥ 0.90, operating range 140 to 270 V, 50 Hz complete including GI pipe bracket of adequate size as required (Light Grade) of length 1.2 mtrs bent to shape and fixed with 40mm x 5mm MS flat with necessary nuts, bolts, washers etc, painting with two coats of syntheic enamel paint over a coat of primer and connecting up with and including three core twisted flexible copper conductor cable of suitable size all as specified & as directed.

50

-

-

... More
Supply & Erecting Steel Tubular Swaged Pole Type 410-SP-31 (9.0 METRE long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Painting over a coat of Aluminium Primer (Externally) above copping shall be painted with in alternate band/strip of black and yellow colour starting with black colour upto height of 1.5 from top of copping, writing MES Pole No. with synthetic Enamel Paint (First Grade/quality) including Dismantling unserviceable Steel Tubular Poles including demolition of Cement Concrete (as/if required) and made good disturbed Ground, complete all as specified and as directed. NOTE: (i) Earthwork, Cement Concrete, etc. will be measured and paid under approprite Items. (ii) Unserviceable Poles will be dismantled at Ground Level and disturbed ground will made good as directed and cost of Earthwork, demolition of Cement Concrete, etc. is deemed to be inclusive in Unit Rate Quoted

3

-

-

... More
S&F Insulator Pin type Porcelain, Vitreous, White, Brown or Green including one Galva-nised Mild Steel Spindle, Two Galvanised Iron Washers and One Galvanised Iron Nut, 100mm Height, 65mm dia for 1100 Volt grade including Dismantling Insulators like from existing Street/ Security Light Pole complete all as specified and as directed.

30

-

-

... More
S&F Shackle type, Porcelain, Vitreous, White or Brown Insulator of size 90mm height 75mm dia including Galvanised Mild Steel 31x3mm Strap, 12mm dia Insulator Bolts, Nuts, Washers, etc. for Working Pressure 1100 Volt, including Dismantling Insulators like from existing Street/ Security Light Pole complete all as specified and as directed.

25

-

-

... More
Re-stringing to OH Line ACSR Conductor on existing Lines by un-binding from the Insulator of any description, re-fixing after stretching the Conductor, removing excess Sag, maintaining proper distance between Conductors as ordered, complete all as specified and as directed. NOTE :– (a)Cost of Binding Wire is deemed to be included in the QUOTED UNIT RATE.

2

-

-

... More
S&F Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) with permissible Sags and providing Jumper, etc.,fixing on Electric Poles and binding to Insulators with Aluminium Binding Wire as in OH Conductors including stringing, tightening, etc., including Dismantling ACSR or AAC Conductors from the Disturbed Span including Line Spacer, etc.complete all as specified and as directed. NOTE: Cost of Binding Wire is deemed to be included in the QUOTED UNIT RATE.

1

-

-

... More
M&L Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, complete all as specified and directed.

1

-

-

... More
M&L Stay Assembly complete with Accessories as show in Electrical Plate No. 1 of MES Schedule Part-I, diameter of Stay Rod 16mm, size of Plate 230x230x6mm including 7/3.15 mm Galvanised Stay Strand,Loop Type Insulator Vitreous White, Brown or Green, large size with overall dimensions 90x65mm, clearance of hole 16mm dia, MS clamp made out of 50mm x 6mm with nuts bolts wahers as required including Dismantling Stay Assembly complete all as specified and as directed. NOTE:(i) Earthwork, Cement Concrete, will be measured and paid under approprite Items. (ii) Unserviceable Stay Assembly will be dismantled at Ground Level and disturbed ground will made good as directed for which Earthwork, demolition of Cement Concrete, etc. is deemed to inclusive in the Unit Rate Quoted

2

-

-

... More
M&L Earthing with Galvanised Steel Earth Plate Electrode 600x600x6mm thick, buried directly in ground vertically to a depth not less than 2.25 METRE below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 METRE below normal ground level, connected to GI Earth Strip 32 x 6 mm drawn through and including GI Pipe 40 mm bore (dia) ‘light grade’ for protection upto 1.00 METRE above the Floor Level of the Building where Main Switch/DB situated, by means of Bolts, Nuts, Check Nuts and Washers etc., Earth Plate surrounded by a packed thickness of Char Coal or coke dust mixed with common Salt in alternate layers of not exc. 150 mm thick, PCC Pit in Cement Concrete 1:3:6 (20 mm graded aggregate) and Pre-cast RCC 1:2:4 (20mm graded aggregate) Cover Slab 350x350 x50mm, reinforced with and including 8.0 mm dia TMT Bars @ 100 mm centre to centre both ways, GI wire mesh, Funnel with GI Watering Pipe 20mm bore (dia) ‘medium grade’, necessary excavation in soft/loose soil, returning, filling in and removal of Surplus Spoil upto a distance of 50 METRE and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion, including dismantling/taking out unserviceable Earthing and connected Items, complete all as specified and as directed NOTES : The unit rate includes for protection pipe and copper strip from top of earth plate up to 7.00 meter above ground level.

3

-

-

... More
S&F in repair of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles duly fixed over insulators or any other indicated situation for loop earthing etc as required with 32 x 6mm GI strip complete all as specified and directed.

20

-

-

... More
S&F in repair Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire, including taking out unserviceable earth conductor complete all as specified and directed.

480

-

-

... More
S&F in repair, MCCB 4 Pole , 415 V, Adjustable thermal and adjustable magnetic, over load and short circuit, neutral adjustment (250-400A), 400 Amps with breaking capacity 50 KA complete all as specified and as directed.

1

-

-

... More
S&F in repair, MCCB 4 Pole , 415 V, Adjustable thermal and adjustable magnetic, over load and short circuit, neutral adjustment (70-100%), 250 Amps with breaking capacity 50 KA complete all as specified and as directed.

1

-

-

... More
S&F in repair, MCCB 4 Pole , 415 V, Adjustable thermal and adjustable magnetic, over load and short circuit, neutral adjustment (70-100%), 200 Amps with breaking capacity 50 KA complete all as specified and as directed.

1

-

-

... More
S&F in repair,Four pole onload changeover switch with advanced neutral having current rating 200 Amp with phase barrier & handle with door interlock kit in Sheet Metal Enclosure complete all as specified and directed.

1

-

-

... More
M&L PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation of pole, mass concrete including necessary formwork ad required complete all as specified and as directed.

1.8

-

-

... More
M&L PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation of pole, including necessary formwork ad required complete all as specified and as directed.

2

-

-

... More
M&L PCC (1:2:4) type B-2 (using 40 mm graded stone aggregate) as in C opping of pole, including necessary formwork ad required complete all as specified and as directed.

0.2

-

-

... More
M&L taking out of the unserviceable panel indicators and allied accessories viz. Ammeters, voltmeters, frequency meters, selector switch, CTs, protective fuses, Neon indicator lamps etc. carefully and keeping in safe custody for replacement / disposal including cleaning of busbar replacement of copper/aluminium thimbles making suitable spaces for fixing of MCCB/Panel meters by cutting and welding suitable as per site duly painted with 2 coats of red oxide paint over a coat of primer complete all as specified and directed Note: Ammeter/Voltmeter/CT/Indicator lamp/Fuse/Selector Switch as required will be measured and paid seperately at Supply Only Rates under appropiate items

2

-

-

... More
Supply only, Digital Ammeter 96 X 96 mm suitable for measuring Alternating Crrent 5A class I complete all as specified and directed

2

-

-

... More
Supply only, Digital Voltmeter 96 X 96 mm suitable for measuring AC Voltage. class I complete all as specified and directed

2

-

-

... More
Supply only, CT for measuring AC on LT 3 phase system, 1.1 kv grade, single burden, general purpose, of CT ratio as per site requirement complete all as specified and directed

6

-

-

... More
Supply only, LED Indicator Lamps for phases flicker type including holders and of colours red / yellow / green / blue etc complete all as specified and directed

12

-

-

... More
Supply only Bakelite kit kat fuse upto 32A rating base with fuse holder complete and all as directed and as specified

3

-

-

... More
Supply only,Selector Switch (cam type) suitable for Ammeter / Voltmeter complete and all as directed and as specified

3

-

-

... More
M&L preparing old painted surfaces by scraping and removing old paints, rust, etc. from Steel Tubular Poles (above the Planting Depth and PCC Copings of 9.0 Metre length Pole) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying one Coat of Red Oxide Zinc Chrome Primer, alternate Yellow & Black Strips Painting (4 No. Each Strip 200 mm wide) and remaining portion of Pole and Cross Arms, Cable Protection Pipe, Brackets, etc. treated with Two Coats of Aluminium Paint, including writing MES Pole No. with synthetic Enamel Paint (First Grade/quality) using stensil in white colour and background in black colour complete all as specified and as directed.

250

-

-

... More
M&L preparing old painted surfaces by scraping and removing old paints, rust, etc. from Pre-stressed Concrete Pole (above the Planting Depth and PCC Copings of 8.5/9 Metre length Pole) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying Two Coats of Synthetic Enamel Painting in alternate Yellow & Black Strips Painting (4 No. Each Strip 200 mm wide) and remaining portion of Pole treated with Two Coats of Exterior Weather Proof Paint and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. treated with Two Coats of Aluminium Paint, including writing MES Pole No. with synthetic Enamel Paint (First Grade/quality) using stensil in white colour and background in black colour complete all as specified and as directed.

30

-

-

... More
S&F PVC Line separtor(Spiral type) for overhead conductor 2 Way, complete all as specified and directed

30

-

-

... More
S&F PVC Line separtor(Spiral type) for overhead conductor 4 Way, complete all as specified and directed

100

-

-

... More
Cutting and removing grass and wild growth including bushes and shrubs from the roots at various E&M installations including removing the wastage materials including broken bricks, stones, boulders etc; and depositing where directed and levelling the entire cleaned area to even finish complete all as specified and directed at site.

150

-

-

... More
M&L Straight through Heat shrinkable joint kit (ouddoor type) with jointing material and accessories suitable for 1100 KV XLPE armoured aluminium conductor cable of size 120 sqmm to 240 sqmm, 3.5 Core, complete all as specified and directed.

2

-

-

... More
M&L Straight through Heat shrinkable joint kit (ouddoor type) with jointing material and accessories suitable for 1100 KV XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm, 3.5 Core, complete all as specified and directed.

2

-

-

... More
M&L Straight through Heat shrinkable joint kit (ouddoor type) with jointing material and accessories suitable for 1100 KV XLPE armoured aluminium conductor cable of size 16 sqmm to 50 sqmm, 3.5 Core, complete all as specified and directed.

3

-

-

... More
M&L Heat shrinkable cable End joint kit (ouddoor type) with jointing material and accessories suitable for 1100 KV XLPE armoured aluminium conductor cable of size 120 sqmm to 240 sqmm, 3.5 Core, complete all as specified and directed.

2

-

-

... More
M&L Heat shrinkable cable End joint kit (ouddoor type) with jointing material and accessories suitable for 1100 KV XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm, 3.5 Core, complete all as specified and directed.

2

-

-

... More
M&L Heat shrinkable cable End joint kit (ouddoor type) with jointing material and accessories suitable for 1100 KV XLPE armoured aluminium conductor cable of size 16 sqmm to 50 sqmm, 3.5 Core, complete all as specified and directed.

10

-

-

... More
Disconnecting the worn out cable of size upto 50 sq mm from main controll panel/Lt OH line cutting worn out portion and reconnecting with controll pannel/LT OH line including fixing of alluminium cable lugs of required size and necessary earth work for taking out cables from loop and relaying the cable in loop with required sand coushioning, brick protection as required complete all as specified and directed by Engineer in charge

4

-

-

... More
Disconnecting the worn out cable of size upto 70-150 sq mm from main controll panel/Lt OH line cutting worn out portion and reconnecting with controll pannel/LT OH line including fixing of alluminium cable lugs of required size and necessary earth work for taking out cables from loop and relaying the cable in loop with required sand coushioning, brick protection as required complete all as specified and directed by Engineer in charge

4

-

-

... More
Disconnecting the worn out cable of size upto 185-400 sq mm from main controll panel/Lt OH line cutting worn out portion and reconnecting with controll pannel/LT OH line including fixing of alluminium cable lugs of required size and necessary earth work for taking out cables from loop and relaying the cable in loop with required sand coushioning, brick protection as required complete all as specified and directed by Engineer in charge

2

-

-

... More
Cutting and trimming of tree branches to clear the over head lines in the arc of LT overhead lines /feeders (including reparing and jointing of ACSR conductor if damaged during cutting of trees) and removal of trimmed branches of tree and depositing the same in waste bin inside the campus all as directed.

80

-

-

... More
Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections and joints including Pipes, Bricks, etc of any description laying in trenches or fixing with Walls/Poles, segreating serviceable Pipes, Cables etc and keep in safe custody for reuse, complete all as specified and as directed. Note : Earthwork will be measured and paid under appropriate Items.

350

-

-

... More
Laying Only LT UG XLPE cable of size 70-120 Sqmm, laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed. Note: (i) LT UG cable 70-120 Sqmm, Shall be reused obtained from Item No here-in-before (ii) Earthwork, Sand coushioning, brick protection will be measured and paid under appropriate Items.

50

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.

100

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.

100

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.

100

-

-

... More
Boring holes horizontally under Road without damaging the surface of Road of any type (minimum 1.0 Metre below the Road Surface) with the help of GI Tubing not exc. 40mm bore (dia) for passing of UG Cable, complete all as specified and as directed. Note : GI Pipe laid will be measured and paid separately under relevant Item.

12

-

-

... More
S&F in repair GI Tubing light grade of size 80mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc complete all as specified and directed.

12

-

-

... More
S&F in repair GI Tubing light grade of size 40mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc complete all as specified and directed.

12

-

-

... More
Taking down unservicable high mast light fittings of any height/watt/make, repair the same in site by opening cover, replace the unserviceable parts unserviceable/burnt cable etc as required at site, after repairing fixing at same position, complete all as specified and as directed. Note:- (a) Spare part i.e. driver wherever required will be measured and paid under appropriate Item(s) as 'supply only'. (b) Labour Element for replacement of unserviceable Parts will deem to be included in the QUOTED UNIT RATE.

2

-

-

... More
Repair, attending and rectifying complaints of street lights fitted on steel tubular/ PCC poles of approx height 9 mtr in the area to the south of railway line by deploying technically qualified and experienced technicians by using T&P/ ladder to become reachable at a height of security light to make the street light functional by checking connection, tighting and removing of carbon/ galvonic corossion etc. complete all as directed Note:- (a) Spare part i.e. driver wherever required will be measured and paid under appropriate Item(s) as 'supply only'. (b) Labour Element for replacement of unserviceable Parts will deem to be included in the QUOTED UNIT RATE.

150

-

-

... More
Supply only Electronic LED driver 45 watt 220/230/240 Volt, complete all as specified and as directed.

10

-

-

... More
Supply only Electronic LED driver 60 watt 220/230/240 Volt, complete all as specified and as directed.

10

-

-

... More
Supply only Electronic LED driver 35/36 watt 220/230/240 Volt, complete all as specified and as directed.

10

-

-

... More
Supply only Electronic Surge Protection device (SPD) 10 KV suitable for LED Security light of Capacity 45 Watt, suitable for 220/230/240 Volt, complete all as specified and directed.

10

-

-

... More
Supply only Electronic Surge Protection device (SPD) 10 KV suitable for LED Security light of Capacity 60 Watt, suitable for 220/230/240 Volt, complete all as specified and directed.

10

-

-

... More
Supply only Electronic Surge Protection device (SPD) 10 KV suitable for LED Security light of Capacity 70 Watt, suitable for 220/230/240 Volt, complete all as specified and directed.

10

-

-

... More
S&F in repair, 2.5 Sqmm, twin core PVC insulated weather proof, sheathed, solid aluminum conductor run through pole/pipe for connection from junction box to light fitting connector block complete all specified and as directed.

500

-

-

... More
S&F LED street light made up off pressure die cast aluminium housing wth toughened glass and high power LEDs as a light source and electronic driver of capacity 45 watts and secondary lenses with IP 66 protection. 10 KV SPD is also included for protection of driver and LEDs, lumen efficacy of light fitting shall be =110 lm/W. and necessary mounting arrangements and provision of 2.5 sq mm three core conductor cable multi stranded from fitting to over head line or Junction box including taking down old unserviceable light fitting.complete all as specified and directed.

60

-

-

... More
S&F LED street light made up off pressure die cast aluminium housing wth toughened glass and high power LEDs as a light source and electronic driver of capacity 60 watts and secondary lenses with IP 66 protection. 10 KV SPD is also included for protection of driver and LEDs, lumen efficacy of light fitting shall be =110 lm/W. and necessary mounting arrangements and provision of 2.5 sq mm three core conductor cable multi stranded from fitting to over head line or Junction box including taking down old unserviceable light fitting.complete all as specified and directed.

40

-

-

... More
S&F Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 flood light fitting luminaire with high power LEDs as light source and electronic driver of capacity 70 watts with lumen efficacy =110 lm/W and 10 KV surge protection device, including taking down old unserviceable fitting complete all as specified and directed.

5

-

-

... More
M&L street light fittings bracket made out from GI pipe 32 mm bore, light grade 1.20 meter long bent to required shape and fixing to poles walls etc including supply and fixing of MS clamp nuts, bolts as required duly painted with two coat of aluminum paint over a coat of red oxide primer including taking out old one, complete all as specified and as directed. Note : The cost of painting shall be deemed to be included in the unit rate quoted against this item

10

-

-

... More
S&F Junction Box for Street Lights of size 205x255x112mm made out of Polycarbonate material totally enclosed, dust and vermin proof, rain protected slanted roof top, door pasted with rubber gasket, water tight IP 66/67 suitable for 10-25 sqmm cable entry, mounted on security light pole with suitable bracket nuts, bolts including removal of exiting unserviceable complete all as specified and directed. Note :- Cable glands shall be fixed in inlet and out let of junction box and rate of Cable glands is deem to be included in quoted rate.

3

-

-

... More
S&F in repair, 3 pole power contactor with control relay with AC Coil suitable for 415 Volts AC supply, with 230 volts relay coil and current rating 63 Amps complete all as specified and directed.

1

-

-

... More
S&F in repair, Time Switch, Digital control,Astronomical type suitable for daily operation in 230 volts AC supply complete all as specified and directed.

4

-

-

... More
S&F in repair, contactor suitable for street light time switchs 3 Pole 40 Amps 415 Volts complete all as specified and directed.

4

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.

100

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.

100

-

-

... More
S&F in repair, GI Tubing light grade of size 32mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc complete all as specified and directed.

18

-

-

... More
S&F in repair, cable lugs suitable for aluminium conductor cable of size 16 Sqmm complete all as specified and directed.

20

-

-

... More
S&F in repair, cable lugs suitable for aluminium conductor cable of size 25 Sqmm complete all as specified and directed.

30

-

-

... More
S&F in repair, cable lugs suitable for aluminium conductor cable of size 35 Sqmm complete all as specified and directed.

30

-

-

... More
S&F in repair, cable lugs suitable for aluminium conductor cable of size 50 Sqmm complete all as specified and directed.

20

-

-

... More
S&F in repair, cable lugs suitable for aluminium conductor cable of size 70 Sqmm complete all as specified and directed.

20

-

-

... More
S&F in repair, cable lugs suitable for aluminium conductor cable of size 95 Sqmm complete all as specified and directed.

10

-

-

... More
S&F in repair, cable lugs suitable for aluminium conductor cable of size 120 Sqmm complete all as specified and directed.

10

-

-

... More
S&F in repair, cable lugs suitable for aluminium conductor cable of size 150 Sqmm complete all as specified and directed.

10

-

-

... More
S&F in repair, cable lugs suitable for aluminium conductor cable of size 185 Sqmm complete all as specified and directed.

10

-

-

... More
S&F in repair, cable lugs suitable for aluminium conductor cable of size 240 Sqmm complete all as specified and directed.

10

-

-

... More
S&F in repair, cable lugs suitable for aluminium conductor cable of size 400 Sqmm complete all as specified and directed.

10

-

-

... More
M&L Surface type sub-main wiring alongwith earth wire of size of 4 x 10.0 sq. mm + 1 x 10.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing capping medium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Four runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED

25

-

-

... More
M&L Surface type sub-main wiring alongwith earth wire of size of 4 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing capping medium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Four runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED

50

-

-

... More
M&L maintance free chemical Earthing system complete with 3 Nos pure copper earth rods 17mm dia, 3000mm long electrode dipped fully in earthing Ennob chemical Backfill compound (EBFC) with minimum 3 Nos of 30Kg bag buried in ground to bore holes 200mm dia vertically to a depth not less than 3.5 mtr deep below the ground level with top edge of earth electrode at a depth not less than 3000mm below normal ground level, interconnected each other parallely in traingle shape horizontaly with provision of copper bus bar of size 32mm x 6mm for interconnection with copper earth lead strip 32mmx6mm for further connected to test point block NABL lab certified back fill eath enhancing compound for filling 3 x bore holes with soil mixed so as to achieve eath resistance below 1 Ohms including necessary Excavation in Soft/Loose Soil, Returning, Filling in and removal of Surplus Spoil upto a distance of 50.00 METRE and provision of Poly Plastic Pit cover for each eathing and testing on completion including taking dismantling/taking unserviceable Earthing complete all as specified and as directed NOTES : (i) The unit rate includes for protection pipe and copper strip from top of earth plate up to 7.00 meter above ground level.

2

-

-

... More
S&F in repair of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles duly fixed over insulators or any other indicated situation for loop earthing etc as required with 32 x 6mm copper strip duly brazed complete all as specified and directed.

12

-

-

... More
S&F in repair Test point terminal block made of gun metal or Phosphorus bronze size 75 x 75 x 25 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw in a test point box complete all as specified and as directed.

2

-

-

... More
S&F in repair GI Tubing light grade of size 40mm dia as in protection pipe for earth conductor fixed with clamp as per site requirement etc complete all as specified and directed.

12

-

-

... More
Day to day routine/periodical preventive maintenance of DG set capacity 1X 250 KVA (No of DG Set - 01 Nos,Make:KIRLOSKAR GREEN) and replacement of Lubricating oil, Oil filters, Fuel filters, Air cleaner elements & top-Up of Coolant as per Manufacturer`s recommended maintanance schedule including health check up of Engine, inspection of Canopy, Alternator & panels and correction of faults by adjustments & settings including supply of all consumable lubricants and repair or replacement of (spare parts) which as specified in notes here-in-after for the DG set 250 KVA and daily/ routine/periodical maintenance as per direction of OEMs or their accredited/ authorised agencies including cleaning complete all as specified and as directed Note :-(i)Spares required will be measured and paid separately (ii) Engine Oil ,Oil Filter & Fuel Filter of above mentioned DG Set will be replaced every six months and will be measured and paid under respective schedule

11

-

-

... More
Day to day routine/periodical preventive maintenance of DG set capacity 1X 200 KVA (No of DG Set - 01 Nos,Make:KIRLOSKAR GREEN) and replacement of Lubricating oil, Oil filters, Fuel filters, Air cleaner elements & top-Up of Coolant as per Manufacturer`s recommended maintanance schedule including health check up of Engine, inspection of Canopy, Alternator & panels and correction of faults by adjustments & settings including supply of all consumable lubricants and repair or replacement of (spare parts) which as specified in notes here-in-after for the DG set 200 KVA and daily/ routine/periodical maintenance as per direction of OEMs or their accredited/ authorised agencies including cleaning complete all as specified and as directed Note :-(i)Spares required will be measured and paid separately (ii) Engine Oil ,Oil Filter & Fuel Filter of above mentioned DG Set will be replaced every six months and will be measured and paid under respective schedule

11

-

-

... More
Day to day routine/periodical preventive maintenance of DG set capacity 02 Nos 82.5 KVA (No. of DG Set -02 No`s Make : Kirloskar) and replacement of Lubricating oil, Oil filters, Fuel filters, Air cleaner elements & top-Up of Coolant as per Manufacturer`s recommended maintanance schedule including health check up of Engine, inspection of Canopy, Alternator & panels and correction of faults by adjustments & settings including supply of all consumable lubricants and repair or replacement of (spare parts) which as specified in notes here-in-after for the DG set 82.5 KVA and daily/ routine/periodical maintenance as per direction of OEMs or their accredited/ authorised agencies including cleaning complete all as specified and as directed. Note :-(i) Spares required will be measured and paid separately (ii) Engine Oil ,Oil Filter & Fuel Filter of above mentioned DG Set will be replaced twice in a year and will be measured and paid under respective schedule

22

-

-

... More
Day to day routine/periodical preventive maintenance of DG set capacity 62.5 KVA (No. of DG Set-01No Make : Kirloskar ) and replacement of Lubricating oil, Oil filters, Fuel filters, Air cleanerelements & top-Up of Coolant as per Manufacturer`s recommended maintanance schedule including health check up of Engine, inspection of Canopy, Alternator & panels and correction of faults by adjustments & settings including supply of all consumable lubricants and repair or replacement of (spare parts) which as specified in notes here-in-after for the DG set 62.5 KVA and daily/ routine/periodical maintenance as per direction of OEMs or their accredited/ authorised agencies including cleaning complete all as specified and as directed. Note :-(i) Spares required will be measured and paid separately (ii) Engine Oil ,Oil Filter & Fuel Filter of above mentioned DG Set will be replaced every six months and will be measured and paid under respective schedule

11

-

-

... More
Day to day routine/periodical preventive maintenance of DG set capacity 15 KVA (No. of DG Set -01No Make : Cummins) and replacement of Lubricating oil, Oil filters, Fuel filters, Air cleanerelements & top-Up of Coolant as per Manufacturer`s recommended maintanance schedule including health check up of Engine, inspection of Canopy, Alternator & panels and correction of faults by adjustments & settings including supply of all consumable lubricants and repair or replacement of (spare parts) which as specified in notes here-in-after for the DG set 15 KVA and daily/ routine/periodical maintenance as per direction of OEMs or their accredited/ authorised agencies including cleaning complete all as specified and as directed. Note :-(i) Spares required will be measured and paid separately (ii) Engine Oil ,Oil Filter & Fuel Filter of above mentioned DG Set will be replaced every six months and will be measured and paid under respective schedule

11

-

-

... More
Day to day routine/periodical preventive maintenance of DG set capacity 7.5 KVA (No. of DG Sets -02No of Make : Greaves Cotton & -01 Nos of Make: Koel Green) and replacement of Lubricating oil, Oil filters, Fuel filters, Air cleanerelements & top-Up of Coolant as per Manufacturer`s recommended maintanance schedule including health check up of Engine, inspection of Canopy, Alternator & panels and correction of faults by adjustments & settings including supply of all consumable lubricants and repair or replacement of (spare parts) which as specified in notes here-in-after for the DG set 7.5 KVA and daily/ routine/periodical maintenance as per direction of OEMs or their accredited/ authorised agencies including cleaningcomplete all as specified and as directed. Note :-(i) Spares required will be measured and paid separately (ii) Engine Oil ,Oil Filter & Fuel Filter of above mentioned DG Set will be replaced every six months and will be measured and paid under respective schedule

33

-

-

... More
Notes for Item No 204 to 209: During each visit under this contract, the following should be carried out by the Service Representative: 1. Checking of Lub Oil from the Sump, Lub oil Cooler etc. and clean the Sump Strainers as per the recommendation in the Operating Instruction Manual. Renew Lub Oil and Filter Elements as required. 2. Refill the sump with new Lub Oil and prime the lubricating system 3. Check and tighten as required, any external bolts. 4. Replace the Fuel Filter Elements as per the recommended procedure. 5. Check and adjust belt tension or replace the belts as required. 6. Check and correct the tightening of all Hoses and Clamps. 7. Check and correct the tightening of terminals at Engine Control Panel and EPU. 8. Check and adjust tappet clearance as required. 9. Check and tighten engine bearer cap screws. 10 Carryout Air Cleaner maintenance as required. 11 Check and record Engine performance parameters. 11. Check and correct external leakages. 12. Check EPU for proper functioning. 13. Checking of Alternator as per check list. 14. Spare parts required will be measured and paid Separately under respective item of schedule. 15 The contractor shall provide of high skilled mechanic/operator joint during currency of contract period, if required. The cost of the same shall be deem to be included above quated rate. 16 Comprehensive maintanance include day to day routine/periodical maintanance with replacement of defective equipments/parts as specified shall deem to be include in above quated rate. 17 Contractor shall rectify the fault within 24 hours as per the direction of AGE E/M within pescribed limit as specified in PS failing which recovery shall be effected 18 Make and model of part to be replaced shall be as existing at site or as per OEM. 19 The cost of transportation and other necessary equipments shall be arranged/brought by contractor in this effect.

-

-

-

... More
Supply only Engine Oil of grade 15W40 complete all as specified and directed

400

-

-

... More
Supply only Engine Oil(Lub Oil) Filter suitable for DG set 250 KVA capacity complete all as specified and directed.

1

-

-

... More
Supply only Air Filter suitable for DG set 250 KVA capacity complete all as specified and directed.

1

-

-

... More
Supply only Fuel filter suitable for DG set 250 KVA capacity complete all as specified and directed.

1

-

-

... More
Supply only Belt of DG Sets as per OEM suitable for DG set 250 KVA capacity complete all as specified and directed.

1

-

-

... More
Supply only Engine Oil(Lub Oil) Filter suitable for DG set 1 Nos 200 KVA capacity complete all as specified and directed.

1

-

-

... More
Supply only Air Filter suitable for DG set 1 Nos 200 KVA capacity complete all as specified and directed.

1

-

-

... More
Supply only Fuel filter suitable for DG set 1 Nos 200 KVA capacity complete all as specified and directed.

1

-

-

... More
Supply only Belt of DG Sets as per OEM suitable for DG set 1 Nos 200 KVA capacity complete all as specified and directed.

1

-

-

... More
Supply only Engine Oil(Lub Oil) Filter suitable for DG set 82.5 KVA capacity complete all as specified and directed.

2

-

-

... More
Supply only Air Filter suitable for DG set 82.5 KVA capacity complete all as specified and directed.

2

-

-

... More
Supply only Fuel filter suitable for DG set 82.5 KVA capacity complete all as specified and directed.

2

-

-

... More
Supply only Belt of DG Sets as per OEM suitable for DG set 82.5 KVA capacity complete all as specified and directed.

2

-

-

... More
Supply only Engine Oil(Lub Oil) Filter suitable for DG set 62.5 KVA capacity complete all as specified and directed.

1

-

-

... More
Supply only Air Filter suitable for DG set 62.5 KVA capacity complete all as specified and directed.

1

-

-

... More
Supply only Fuel filter suitable for DG set 62.5 KVA capacity complete all as specified and directed.

1

-

-

... More
Supply only Belt of DG Sets as per OEM suitable for DG set 62.5 KVA capacity complete all as specified and directed.

1

-

-

... More
Supply only Engine Oil(Lub Oil) Filter suitable for DG set 15 KVA capacity complete all as specified and directed.

1

-

-

... More
Supply only Air Filter suitable for DG set 15 KVA capacity complete all as specified and directed.

1

-

-

... More
Supply only Fuel filter suitable for DG set 15 KVA capacity complete all as specified and directed.

1

-

-

... More
Supply only Belt of DG Sets as per OEM suitable for DG set 15 KVA capacity complete all as specified and directed.

1

-

-

... More
Supply only Engine Oil(Lub Oil) Filter suitable for DG set 3 Nos 7.5 KVA capacity complete all as specified and directed.

2

-

-

... More
Supply only Air Filter suitable for DG set 3 Nos 7.5 KVA capacity complete all as specified and directed.

2

-

-

... More
Supply only Fuel filter suitable for DG set 3 Nos 7.5 KVA capacity complete all as specified and directed.

2

-

-

... More
Supply only Belt of DG Sets as per OEM suitable for DG set 3 Nos 7.5 KVA capacity complete all as specified and directed.

2

-

-

... More
M&L Servicing radiator assembly from its existing position and opening of the radiator , overhauling , cleaning with chemical and mechanical process reassembling with replacement of gaskets and cleaning of fins also and soldering on required leaked galleries for 250/200 KVA DG Sets complete all as directed.

2

-

-

... More
M&L Servicing radiator assembly from its existing position and opening of the radiator , overhauling, cleaning with chemical and mechanical process reassembling with replacement of gaskets and cleaning of fins also and soldering on required leaked galleries for 82.5/62.5 KVA DG Sets complete all as directed.

2

-

-

... More
M&L Servicing radiator assembly from its existing position and opening of the radiator , overhauling, cleaning with chemical and mechanical process reassembling with replacement of gaskets and cleaning of fins also and soldering on required leaked galleries for 15/7.5 KVA DG Sets complete all as directed.

1

-

-

... More
M&L dismantling carefully Fuel Injenction Pump (FIP) of 250/200 KVA DG Set Opening, cleaning of FIP and nozzles , recalibration with replacement of element ,Delivery valve and Repair kit and refitting to the engine after repair/replacement and making DG SET proper functional complete all as directed.

2

-

-

... More
M&L dismantling carefully Fuel Injenction Pump (FIP) of 82.5/62.5 KVA DG Set Opening, cleaning of FIP and nozzles recalibration with replacement of element ,Delivery valve and Repair kit and refitting to the engine after repair/replacement and making DG SET proper functional complete all as directed.

1

-

-

... More
M&L dismantling carefully Fuel Injenction Pump (FIP) of 15/7.5 KVA DG Set Opening, cleaning of FIP and nozzles recalibration with replacement of element ,Delivery valve and Repair kit and refitting to the engine after repair/replacement and making DG SET proper functional complete all as directed.

1

-

-

... More
M&L dismantling Water Pump Assembly from the 250/200 KVA DG Set, from its existing position ,Opening into parts Overhauling the same ,repairing and refixing complete to make the DG Set Functional complete all as directed.

1

-

-

... More
M&L dismantling Water Pump Assembly from the 82.5 / 62.5 KVA DG Set,from its existing position ,Opening into parts Overhauling the same ,repairing and refixing complete to make the DG Set Functional complete all as directed.

1

-

-

... More
M&L dismantling Water Pump Assembly from the 15/7.5 KVA DG Set, from its existing position ,Opening into parts Overhauling the same ,repairing and refixing complete to make the DG Set Functional complete all as directed.

1

-

-

... More
M&L taking down unserviceable self starter including solenoid switch repairing unserviceable parts like Carbon bush, Pinion , armature ,Carbon Brush Holder etc and refixing self starter 24 volt suitable for DG Set 250/200 KVA all as specified and directed.

1

-

-

... More
M&L taking down unserviceable self starter including Solenoid Swich and repairing unserviceable parts like Carbon bush, Pinion , armature ,Carbon Brush Holder etc and refixing self starter 24 volt suitable for DG Set 82.5/62.5 KVA all as specified and directed.

1

-

-

... More
M&L taking down unserviceable self starter including Solenoid Switch and repairing unserviceable parts like Carbon bush, Pinion , armature ,Carbon Brush Holder etc and refixing self starter 12 volt suitable for DG Set 15/7.5 KVA all as specified and directed.

1

-

-

... More
M&L taking down unserviceable 24 Volts Dynamo and repairing by rewinding and Varnishing , heating of coil and refixing suitable for DG Set 250/200 KVA all as specified and directed.

1

-

-

... More
M&L taking down unserviceable 12 Volts Dynamo and repairing by rewinding and Varnishing , heating of coil and refixing suitable for DG Set 82.5/62.5 KVA all as specified and directed.

1

-

-

... More
M&L taking down unserviceable 12 Volts Dynamo and repairing by rewinding and Varnishing , heating of coil and refixing suitable for DG Set 15/7.5 KVA all as specified and directed.

2

-

-

... More
S&F in repair, Battery Charger 12/24 Volts complete all as specified and directed.

1

-

-

... More
S&F in repair, Battery of Capacity 180 Ah , 12 Volts complete all as specified and directed.

3

-

-

... More
Supply and top up distilled water complete all as directed.

260

-

-

... More
Supply and top up Pre mixed heavy duty Coolant complete all as directed.

316

-

-

... More
M&L servicing of AMF Panel and Repair and replacement of AMF Controller Panel of capacity 250 KVA diesel generating set as per existing complete all as specified and directed.

1

-

-

... More
M&L servicing of AMF Panel and Repair and replacement of AMF Panel relay of capacity 250 KVA diesel generating set as per existing complete all as specified and directed.

1

-

-

... More
M&L servicing of AMF Panel and Repair and replacement of AMF Panel contactor(as per existing) of capacity 250 KVA diesel generating set as per existing complete all as specified and directed.

1

-

-

... More
M&L servicing of AMF Panel and Repair and replacement of AMF Controller Panel of capacity 82.5 KVA diesel generating set as per existing complete all as specified and directed.

1

-

-

... More
M&L servicing of AMF Panel and Repair and replacement of AMF Panel relay of capacity 82.5 KVA diesel generating set as per existing complete all as specified and directed.

1

-

-

... More
M&L servicing of AMF Panel and Repair and replacement of AMF Panel contactor(as per existing) of capacity 82.5 KVA diesel generating set as per existing complete all as specified and directed.

1

-

-

... More
M&L servicing of AMF Panel and Repair and replacement of AMF Controller Panel of capacity 7.5 KVA diesel generating set as per existing complete all as specified and directed.

1

-

-

... More
M&L servicing of AMF Panel and Repair and replacement of AMF Panel relay of capacity 7.5 KVA diesel generating set as per existing complete all as specified and directed.

1

-

-

... More
M&L servicing of AMF Panel and Repair and replacement of AMF Panel contactor(as per existing) of capacity 7.5 KVA diesel generating set as per existing complete all as specified and directed.

1

-

-

... More
Taking Out Automatic Voltage Regulator of Alternator and replacing the same after testing complete for 250/200 KVA DG Set all as specified and directed.

1

-

-

... More
Taking Out Automatic Voltage Regulator of Alternator and replacing the same after testing complete for 82.5/62.5 KVA DG Set all as specified and directed.

1

-

-

... More
Taking Out Automatic Voltage Regulator of Alternator and replacing the same after testing complete for 15 KVA DG Set all as specified and directed.

1

-

-

... More
Taking Out Automatic Voltage Regulator of Alternator and replacing the same after testing complete for 7.5 KVA DG Set all as specified and directed.

1

-

-

... More
M&L opening ,cleaning and refixing of diesel tank of 250/200 KVA DG Set twice during the contract peroid. Cleaning of diesel tank involves draining out of diesel collecting in a vessal and refueling the diesel complete all as specified and directed. Note :- Necessary tools and plants required for opening and refixing should be arranged by the contractor.

2

-

-

... More
M&L opening ,cleaning and refixing of diesel tank of 82.5/62.5 KVA DG Set twice during the contract peroid. Cleaning of diesel tank involves draining out of diesel collecting in a vessal and refueling the diesel complete all as specified and directed. Note :- Necessary tools and plants required for opening and refixing should be arranged by the contractor.

3

-

-

... More
M&L opening ,cleaning and refixing of diesel tank of 15/7.5 KVA DG Set twice during the contract peroid. Cleaning of diesel tank involves draining out of diesel collecting in a vessal and refueling the diesel complete all as specified and directed. Note :- Necessary tools and plants required for opening and refixing should be arranged by the contractor.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.