Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date7 May 2024
Closing Date4 Jun 2024
Tender Amount₹ 13,70,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M & L for replacement of breather assembly made with polycarbonate base and clear acylic glass of size min 50mm dia, min 120 mm long or suitable size as per site requirement for transformer complete all as specified and directed.

10

-

-

... More
M & L for replacement of transformer temperature gauge dial type having temp range 0 to minimum 120 degree celcius complete all as specified and directed.

6

-

-

... More
M&L for openning of top cover at situ or at wksp by unscrewing all nuts, bolts & washers, draining out transformer oil upto required level and keeping in clean container for replacement of HT/LT bushings, for lifting of core assy, for cleanning/repair and refixing complete with new cork sheet gasket, existing/new nuts, bolts & washers for transformer indoor/outdoor type, refilling of oil all as specified and directed for transformer capacity upto100 KVA to 200 KVA, 11/0.433 KV volts grade.. (Note:- HT/LT bushings, Studs, Brass stud, Nuts, bolts & washers required shall be measured and paid separately under relevant items of the schedule)

3

-

-

... More
All as per items No-06 here-in-before but for transformer capacity 250-400 KVA.

1

-

-

... More
M&L for replacement of transformer porcelain bushing outdoor/indoor type in situ/wksp suitable for 11 KV grade complete with brass studs, rubber bush, washers, nuts, checknuts and cork sheet gasket for the rating of 100 KVA to 200 KVA, 11/0.415 KV transformer complete all as specified and directed.

7

-

-

... More
All as per items No-8 here-in-before but for transformer capacity 250-400 KVA.

6

-

-

... More
M&L for replacement of transformer LT porcelain bushing indoor/outdoor type in situ/wksp suitable for 1100 volts grade complete with rubber bush, washers, nuts, checknuts and cork sheet gasket for the rating of 100 KVA, to 200 KVA 11/0.433 KV transformer complete all as specified and directed. Note:(i) Brass Stud shall be measured and paid separately under relavant item

4

-

-

... More
All as per item No-10 here-in-before but for transformer capacity 250-400 KVA,

4

-

-

... More
M&L for replacement of brass stud suitable for LT 1100 volts grade with con & rubber washer, double Brass nuts & brass washer at both end of stud for Tfr cap 100 KVA to 200 KVA.

12

-

-

... More
All as per item Ser No-12 here-in-before but for transformer capacity 250-400 KVA

8

-

-

... More
Taking out manually defective transformer of capacity 100 KVA to 200 KVA from its position by dismantling LT/HT cables, earthing and earthing strip upto road n. exc 1 KM and transportation by vehicle to workshop n. exc 30 KM and reinstallation at original position after repair or Shiting of transformer from present location to original location including connection of all HT/LT cabes, earthing and earthing strip and testing all as specified and directed. (Note: a) Rate deemed to included for disconnecting and reconnecting of necessary HT/LT cable/ACSR, earthing connection before and after installation)

2

-

-

... More
All as per items No-14 here-in-before but for transformer capacity 250 to 315 KVA.

2

-

-

... More
M & L for lifting the transformer core carefully after dismantling terminal connections from core to HT/LT bushings, tap changer assy, drainout all oil and keeping in clean container and keeping the heating chamber for necessary value of insulation resistance, dismantling defective HT & LT coils from core for rewinding, and reassembling complete with HT/LT coils to core, required necessary numax paper insulation, insulating press board, precompressed board size of 6mm/3mm/1.5mm/1mm, varnishing, heating to achive insulation level not less than 1000 megaohms at both HT & LT side, core at transformer chamber, tap changer assy, terminal connection, top cover with new cork sheet gusket, required existing/new nuts, bolts & washers, filling transformer oil, testing after repair complete all as specified and directed for the 100 to 200 KVA, 11/0.415 KV transformer. Note:- (i) Opening of top cover, Rewinding of HT/LT coils, transformer oil, nuts, bolts & washers, HT/LT busings, required shall be measured and paid separately under relavant items of the schedule. (ii) Test result shall be kept in record duly signed by all concerned (iii) Testing record will be prepared by contractor.

2

-

-

... More
All as per items No-16 here-in-before but for transformer capacity 250-315 KVA.

2

-

-

... More
M&L for rewinding of HT coils suitable for 11000 volts grade with new DPC/super enamelled copper wire having Class-F insulation as per existing size and turns for capacity of transformer 100 to 400KVA KVA

90

-

-

... More
M&L for rewinding of LT coils suitable for 1100 volts grade with new DPC /super enamelled copper strip having Class-F insulation as per existing size and turns for capacity of transformer 100 to 315 KVA

110

-

-

... More
M&L for replacement of Tap changer assy having 7 position of transformer including dismantling and taking out old unserviceable one and dismantling all winding terminal connections and reconnecting after replecement complete upto transformer cap 400 KVA 11/0.433 KV.

2

-

-

... More
M&L for painting of transformer outer surface installed at various electric sub station/ pump housed, in situ/wksp with one coat of synthetic enamel paint using sprayer for transformer capacity 100 to 200 KVA after preparation of old painted surface including writing M/C No. (Note : (i) During process of painting, transformer will be under shut down for the period and the rate deemed to be included for running the sprayer machine with own arrangement by contractor. (ii) After completion of painting HT/LT outdoor bushing, cable termination joint, Oil inspection glass and name plates to be made clean using volatile cleanner)

4

-

-

... More
All as per items No-21 here-in-before but for transformer capacity 250-315 KVA.

2

-

-

... More
S&F in repair HT lightening arrester expulsion type with all fittings discharging capacity 65 KA 11000 volts grade complete all as directed. Make :- Alstom/Oblum/Crompton Greaves.

7

-

-

... More
Material and labour for earthing complete with galvanized steel plate electrodes of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanized strip of size 32 x 6 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore ( light grade) for poles/lightening arrestors/GO Switch/ transformer/panel including connection to HT overhead lines all as directed including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 55x55x15 cm with one handle for lifting made out of 8 mm diameter MS bar finnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No. 3 of SSR Part-I including testing on completion complete all as specified and directed. Note : Result of earthing should be as per earth resistivity.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.