Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_680813_1Tender No
606/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M & L for cement concrete 1:4:8 typr D-2 using 40 mm graded stone aggegrate in foundation, filling and mass complete all as specified and directed.
0.27
-
-
M & L for cement concrete 1:3:6 typr C-2 using 40 mm graded stone aggegrate in foundation, filling and mass complete all as specified and directed.
3.24
-
-
M & l for providing cement concrete 1:2:4 type B-1 using 20 mm graded stone aggegrate in copings to poles & the like etc including weathering,slightly rounded or chamfered angles and throating as complete all as specified and diected.
0.46
-
-
Taking out of 11 KV 3 core 95 sqmm HT cable from duct/trench by taking proper electric shut down from AGE E/M (AF) Chabua and making good to the disturbed surface complete all as specified and as directed.
630
-
-
Taking out of 11 KV 3 core 240 sqmm HT cable from duct/trench by taking proper electric shut down from AGE E/M (AF) Chabua and making good to the disturbed surface complete all as specified and as directed.
25
-
-
Supply, laying in trenches/through pipes under road, floor/ on wall/on pole or any other indicated place & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)with stranded aluminum conductor, 11000 volts grade, of size 3 core 95 sq mm complete all as specified.
230
-
-
Supply, laying in trenches/through pipes under road, floor/ on wall/on pole or any other indicated place & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)with stranded aluminum conductor, 11000 volts grade, of size 3 core 240 sq mm complete all as specified.
25
-
-
Relaying of existing serviceable XLPE insulated,armoured,heavy duty,PVC sheathed electric cable with aluminium conductor,11000 volts grade connecting cross sectional area 95 sqmm 3 core all as directed at site
400
-
-
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
230
-
-
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
177
-
-
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
53
-
-
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
46
-
-
Re-laying of existing serviceable HT Cable cover of size 300x180x50 mm complete all as specified and directed at site.
1000
-
-
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx 180mm x 40mm laid in trenches as cable covers complete all as directed.
2150
-
-
Supply and fix in repair 33 KV Lightning arresters expulsion type with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed at site.
1
-
-
Supply and fix in repair 11 kV Lightning arresters expulsion type with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed at site.
3
-
-
M&L in repair triple pole mechanical operated , mounted on insulator with operating mechanisam worked from ground level for current rating 400 amps amps suitable for 33000 volts complete all as specified and directed.
1
-
-
M&L in repair triple pole mechanical operated , mounted on insulator with operating mechanisam worked from ground level for current rating 400 amps amps suitable for 11000 volts complete all as specified and directed.
6
-
-
Supply and fix in repair of cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint with jointing material and accessories complete suitable for 3 core XLPE aromoured aluminium conductor cable of size 95 sq mm.
10
-
-
Supply and fix in repair of cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE aromoured aluminium conductor cable of size 95 sq mm.
10
-
-
Supply and fix in repair of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm.
6
-
-
Supply and fix in repair of cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint with jointing material and accessories complete suitable for 3 core XLPE aromoured aluminium conductor cable of size 240 sq mm.
1
-
-
Supply and fix in repair of cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE aromoured aluminium conductor cable of size 240 sq mm.
1
-
-
Supply and fix in repair of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm.
2
-
-
M&L for drop out fuse suitable for 33000 volts grade complete all as specified and directed.
1
-
-
M&L for drop out fuse single pole suitable for 11000 volts grade upto 50 amps complete all as specified and directed.
12
-
-
Attending of 33/11 KV HT breakdown and finding the fault in transformers, VCBs,HT UG cables, CTs,PTs, lighting arrestor, insulator etc by highly skilled mechanic to replace any sparss related breakdown complete all as specified and directed at site. (a) a sum of Rs 4000.00/day will be recovered in case of not attend break down by service Engineer and not rectified defect with in 24 Hrs. (b) Spares parts will be measured and paid under respective items.
(c) Labour to be included the quoted rates
5
-
-
Supply and stringing in repair ACSR conductor of any size for HT/LT over head line as directed including fixing to insulators with proper size of binding wire complete.
2.5
-
-
All as per item 31 but GI wire 4 mm dia complete.
1.5
-
-
M&L in repairs for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of alminum paint over a coat of red oxide primer, complete all as directed.
2.5
-
-
M&L for replacement of pin type insulator porcelain, votreous, white, brown or green insulator including one galvnised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for working pressure 33000 volts grade complete all as specified and directed.
3
-
-
M&L for replacement of disc type insulator, porcelain, vitreous and socket type white,brown or green single disc assy for tension with tension clamps for conductors,working pressure 33000 volts complete all as specified and directed.
3
-
-
M&L for replacement of pin type insulator porcelain, votreous, white, brown or green insulator including one galvnised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for working pressure 11000 volts grade complete all as specified and directed.
40
-
-
M&L for replacement of disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type white,brown or green single disc assy for tension with tension clamps for conductors,working pressure 11000 volts complete all as specified and directed.
9
-
-
Supply and fixing in repair steel tubes, galvanised, light grade, ISI marked 80 mm bore for protection of cable under floor, road and on wall complete.
18
-
-
Supply and fixing in repair steel tubes, galvanised, light grade, ISI marked 100 mm bore for protection of cable under floor, road and on wall complete.
24
-
-
M&L for painting of HT tubular poles up to 11 mtr long in two coats of aluminium paint and one coat of red oxide as primer including writing of pole nos all as specified and directed at site.
100
-
-
Material and labour, painting of two pole structure consisting of 11m long steel tubular poles including cross arms, clamps of any length and shape, for HT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm dia circle and marking bottom of pole to 1.5m height, complete all as specified and directed.
5
-
-
Material and labour, painting of three pole structure consisting of 11m long steel tubular poles including cross arms, clamps of any length and shape, for HT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm dia circle and marking bottom of pole to 1.5m height, complete all as specified and directed.
4
-
-
Material and labour, painting of four pole structure consisting of 11m long steel tubular poles including cross arms, clamps of any length and shape, for HT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm dia circle and marking bottom of pole to 1.5m height, complete all as specified and directed.
4
-
-
Material and labour, painting of six pole structure consisting of 11m long steel tubular poles including cross arms, clamps of any length and shape, for HT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm dia circle and marking bottom of pole to 1.5m height, complete all as specified and directed.
1
-
-
Material and labour, painting of eight pole structure consisting of 11m long steel tubular poles including cross arms, clamps of any length and shape, for HT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm dia circle and marking bottom of pole to 1.5m height, complete all as specified and directed.
1
-
-
M&L for spray painting of transformer preparation of old painted surfaces of steel body by brushing/cleaning stain, greasy spots with thinner outside of transformer indoor/outdoor type capacity 63 KVA to 160 KVA to match with existing colour as per direction by Engr-in-Charge.
7
-
-
All as per ser item No 46 above nere-in-before but capacity of 200 KVA to 315 KVA
10
-
-
All as per ser item No 46 above nere-in-before but capacity of 500 KVA to 630 KVA
4
-
-
All as per ser item No 46 above nere-in-before but capacity of 800/1000 KVA
3
-
-
Re-stringing Over Head Line ACSR Conductor and earth wire of any size and type on HT poles including disconnection on Existing Lines by un-binding at Each Pin/Shackle Type Insulator, re-fixing the same after stretching Conductor, removing excess Sag, maintaining proper distance between Conductors adjusting line dividers etc and cutting trimming of tree branches upto 2 mtr clear distance from wire, complete all as directed by Engr-in-Charge.
4
-
-
Supplying and laying synthetic Rubber insulated mats 3 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m
4
-
-
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m
2
-
-
Dehydration of HV/EHV grade transformer oil (On line/off line), to achieve dielectric strength upto 60KV for EHV grade and upto 40 KV for HV grade, complete all as specified and directed. Note - Centrifuging Machine with all T&P & testing eqpt required for dehydration to be arranged by the contractor.
15400
-
-
Supply and filling, transformer oil EHV grade as per IS-335 of 1993 Part-II for top up / replacment as per direction by Engr-in-Charge.
2050
-
-
M & L for rewinding HT/LV coils of transformer by using proper size super enameld copper wire suitable for working voltage 11 KV/0.433 KV including three layer insulated material as per existing size of core including testing and commissioning complete all as specified and directed at site.
NOTE :-
i). Oil filtration,supply of new oil will be measured separately.
ii). All petty parts including nut, bolts, gasket minor weldings are deemed to be included the rate quoted.
iii). The rate for taking out,refixing after repair,both side transportation, lifting /unloading of voltage stabilizer/isolation transformer by crane /manual should be deemed to include in the rate quoted.
150
-
-
Disconnecting HT supply and taking out defective trolley of 11 KV VCB of any make and type and servicing of VCB by cleaning isolating contacts moving parts removing dust particles from bus bar chamber spout gear mechanism and moving parts, repair to motor charge spring mechanism tightening of nut & bolts of entire trolley components and replacement of all unserviceable spares as required and all as directed, inserting in trolley, testing commissioning and putting on the supply on load complete all as directed by the Engr-in-charge.
Note: - (i) Servicing will be done once in every 06 months or as directed by Engr-in-Charge (ii) Servicing/repairs will be carried out by OEM's authorised dealer only. (iii) Spares as required for replacement will be of the same company as of existing make or as recommended by the OEM (iv) Cost of spares will be measured and paid separately under relevant items.
(v)) All Measuring equipments and T&P required shall be arranged by the contractor.
33
-
-
Digital volt meter (1 Phase) suitable for 11 KV VCB of rating 400/630/800 amps as per existing make and model .
6
-
-
Digital amp meter (1 Phase) suitable for 11 VCB of rating 400/630/800 amps as per existing make and model .
6
-
-
Charging motor suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model .
2
-
-
Vacuum interrupter suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model
2
-
-
Tripping push button suitable for 11KV VCB of rating 400/630/800 Amps as per existing make and model
4
-
-
Single unit resin cast type current Transformer of rating 11 KV, ratio 50-25/5-5A, burden 5P10 for protection and 10VA for metering
3
-
-
Single unit resin cast type potential Transformer of rating 11 KV, ratio 11KV/ √3/110V/√3 burden 100VA, pistol type
3
-
-
Relay suitable for 11 KV VCB of rating 400/630/800 amps
2
-
-
Relay suitable for 33 KV control panel
2
-
-
Limit switch suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model
2
-
-
11 KV PT HRC fuse AVT type 0.5 to 6 Amp and 2.5 KV to 36 KV as per existing make and model
1
-
-
Fixed contact block suitable for 11 KV VCB for rating 400/630/800 Amps as per existing make and model
1
-
-
Moving contact block suitable for 11 KV VCB as per existing make and model
1
-
-
Closing coil assembly 24 Volts DC suitable for 11 KV VCB as per existing make and model
1
-
-
Tripping coil assembly 24 Volts DC suitable for 11 KV VCB as per existing make and model
1
-
-
Mechanical Castle interlock assembly with Key suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model
1
-
-
Busbar Spout suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model
15
-
-
Vaccum spout suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model
1
-
-
Supply and fix in replacement Tap changer assy of 11/0.433 KV transformer 500 to 800 KVA including replacing worn out connection sleeves, insulated plates, nut, bolts & washers and testing after replacement complete all as specified and directed.
1
-
-
S & F in repairs LT bushing with brass stud, packing ,nut, bolt, washers etc suitable for 500 KVA to 630 KVA 11000/433V complete all as specified and directed.
1
-
-
S & F in repairs HT bushing with brass stud, packing ,nut, bolt, washers etc suitable for 500 KVA to 630 KVA 11000/433V complete all as specified and directed.
1
-
-
S & f in repair Transformer top cover gasket/cock sheet suitable for 63 KVA to 160 KVA transformer complete all as specified and directed at site.
4
-
-
S & f in repair Transformer top cover gasket/cock sheet suitable for 200 KVA to 315 KVA transformer complete all as specified and directed at site.
5
-
-
S & f in repair Transformer top cover gasket/cock sheet suitable for 500 KVA to 630 KVA transformer complete all as specified and directed at site.
3
-
-
S & F in repairs bushing with brass stud, packing ,nut, washers etc on primary side suitable for 7.5 MVA, primary side complete all as specified and directed.
3
-
-
Supply and fixing in repalcement of heavy duty breather assembly of capacity 0.5 kg with silica gel cristal complete all as specified.
8
-
-
Supply and filling silica gel cristal in to breather assembly complete all as specified and directed at site.
6
-
-
Supply and fixing, in replacement of 33 KV potentional transformer out door type of ratio 200-100/5 complete all as specified and directed by engr-in-charge.
1
-
-
Supply and fixing, in repair of 33 KV current transformer out door type of ratio 200-100/5 complete all as specified and directed by engr-in-charge.
1
-
-
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique/Manual and necessary machine suitable for 80/100 mm GI pipe complete all as specified and directed at site
24
-
-
Supply and fix in repair of LED indication lamp for VCB control panel complete all as specified and directed at site.
17
-
-
Supply and fixing in repairs gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 25 mm bore pipe.
2
-
-
M&L for spreading of graded crashed aggregate 40mm nominal size to a true surface and leveled in layers not exc. 20 cm thick for switch yard complete all as specified and directed by Engr-in-Charge.
10
-
-
Supply and fixing in repairs gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 50 mm bore pipe.
1
-
-
Supply and fixing, in replacement of MCBs , DP , 240 Volts , 5 to 40 Amps , 10 kA , AC/DC complete all as specified and directed.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%