BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Electrical Generators And Transformers
Machinery and Tools
Electrical and Electronics
Eprocure
Opening Date10 Sep 2024
Closing Date3 Oct 2024
Tender Amount₹ 45,49,166 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M & L for Servicing to DG set of capacity 125 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at REKHAMARI PH & MRO HUB (i)  Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v)  Air filter - 01 set (vi)  Cleaning of fuel tank - 01 Job (vii)  Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job

2

-

-

... More
M & L for Servicing to DG set of capacity 100 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at 180 MH & LAMA Camp PH (i)  Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v)  Air filter - 01 set (vi)  Cleaning of fuel tank - 01 Job (vii)  Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job

2

-

-

... More
M & L for Servicing to DG set of capacity 82.5 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at Shivaji Nagar St Light & UAV (CCR) troop (i)  Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v)  Air filter - 01 set (vi)  Cleaning of fuel tank - 01 Job (vii)  Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job

2

-

-

... More
M & L for Servicing to DG set of capacity 62.5 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at Engr Regt (Stn HQ), 571 ASC Bn, Perimeter lights (Rekhamari, Nepali Basti), Buffle range, 667 MI room, SPS-A CHHATAGHAR (i)  Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v)  Air filter - 01 set (vi)  Cleaning of fuel tank - 01 Job (vii)  Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job

7

-

-

... More
M & L for Servicing to DG set of capacity 40 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at 15 Mobile, STP Pratap Nagar-I & 180 MH Oxygen plant, Stn HQ DG (i)  Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v)  Air filter - 01 set (vi)  Cleaning of fuel tank - 01 Job (vii)  Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job

4

-

-

... More
M & L for Servicing to DG set of capacity 35 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at UAV Troop (06 Nos), MES IB (i)  Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v)  Air filter - 01 set (vi)  Cleaning of fuel tank - 01 Job (vii)  Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job

13

-

-

... More
M & L for Servicing to DG set of capacity 30 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at STP SPS-E 571 ASC KLP (i)  Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v)  Air filter - 01 set (vi)  Cleaning of fuel tank - 01 Job (vii)  Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job

1

-

-

... More
M & L for Servicing to DG set of capacity 25 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at CCR Sub Stn (i)  Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v)  Air filter - 01 set (vi)  Cleaning of fuel tank - 01 Job (vii)  Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job

1

-

-

... More
M & L for Servicing to DG set of capacity 15 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at 11 Para SF 02 Nos (i)  Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v)  Air filter - 01 set (vi)  Cleaning of fuel tank - 01 Job (vii)  Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job

2

-

-

... More
M & L for Servicing to DG set of capacity 10 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at Stn HQ (MI Room Pratap Nagar) (i)  Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v)  Air filter - 01 set (vi)  Cleaning of fuel tank - 01 Job (vii)  Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job

1

-

-

... More
M&L Battery leads complete with terminal and lugs (set of three Nos) including removal of existing unserviceable one complete all as directed.

10

-

-

... More
M&L Battery leads complete with terminal and lugs (set of two Nos) including removal of existing unserviceable one complete all as directed.

12

-

-

... More
M&L Fan Belt complete suitable for DG set of capacity 100 to 500 KVA including removal of existing unserviceable one compete all as specified and directed.

24

-

-

... More
M&L Fan Belt complete suitable for DG set of capacity 82.5 to 7.5 KVA including removal of existing unserviceable one compete all as specified and directed.

34

-

-

... More
M&L Radiator Fan Blade complete suitable for capacity 7.5 to 82.5 KVA including removal of existing unserviceable one compete all as specified and directed.

6

-

-

... More
M&L Radiator Fan Blade complete suitable for capacity 100 to 500 KVA including removal of existing unserviceable one compete all as specified and directed.

6

-

-

... More
M&L disconnecting all electrical connections from DG set alternator of any capacity from base plate by opening nuts & bolts keeping aside the alternator for inspection and testing & commissioning complete all as specified & directed.

6

-

-

... More
M&L Rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing of 7.50 KVA to 15.00 KVA DG complete all as specified and directed.

2

-

-

... More
M&L Rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing of 20 KVA to 40 KVA DG complete all as specified and directed.

2

-

-

... More
M&L Rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing of 62.5 KVA to 82.5 KVA DG complete all as specified and directed.

1

-

-

... More
M&L Rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing of 100 KVA to 125 KVA DG complete all as specified and directed.

1

-

-

... More
M&L Self Starter assembly 24 Volts complete suitable for 100 KVA to 500 KVA DG set including removal of existing unserviceable one compete all as specified and directed.

2

-

-

... More
M&L Self Starter assembly 12 Volts complete suitable for 7.5 KVA to 82.5 KVA DG set including removal of existing unserviceable one compete all as specified and directed.

2

-

-

... More
M&L DC Alternator assembly 24 Volts complete suitable for 100 KVA to 500 KVA DG set including removal of existing unserviceable one compete all as specified and directed.

2

-

-

... More
M&L DC Alternator assembly 12 Volts complete suitable for 7.5 KVA to 82.5 KVA DG set including removal of existing unserviceable one compete all as specified and directed.

2

-

-

... More
M&L Electronic speed control unit assembly suitable for 24Volts battery charger including removal of existing unserviceable one compete all as specified and directed.

2

-

-

... More
M&L SMPS (System main power supply) control unit assembly 24Volts complete suitable 100 KVA to 500 KVA DG set including removal of existing unserviceable one compete all as specified and directed.

3

-

-

... More
M&L SMPS (System main power supply) control unit assembly 12Volts complete suitable 100 KVA to 500 KVA DG set including removal of existing unserviceable one compete all as specified and directed.

3

-

-

... More
M&L AVR (Automatic Voltage regulator) control unit assembly suitable 7.5 KVA to 82.5 KVA DG set including removal of existing unserviceable one compete all as specified and directed.

4

-

-

... More
M&L AVR (Automatic Voltage regulator) control unit assembly suitable 100 KVA to 500 KVA DG set including removal of existing unserviceable one compete all as specified and directed.

4

-

-

... More
M&L Brass battery terminals extended type heavy grade including removal of existing unserviceable one compete all as specified and directed.

22

-

-

... More
M&L SS canopy Stainless steel hinges as per original OEM for acoustic doors with suitable Stainless steel bolts and nuts of DG set including removal of existing unserviceable one compete all as specified and directed.

20

-

-

... More
M&L Radiator hose pipe with suitable clamps of DG set including removal of existing unserviceable one compete all as specified and directed.

12

-

-

... More
M&L solenoid switch assembly 24 volts suitable for 100 KVA to 400 KVA DG set including removal of existing unserviceable one compete all as specified and directed.

3

-

-

... More
M&L solenoid switch assembly 12 volts suitable for 7.5 KVA to 82.5 KVA DG set including removal of existing unserviceable one compete all as specified and directed.

4

-

-

... More
M&L Anti vibration pads with suitable bolts and washers including removal of existing unserviceable one compete all as specified and directed.

4

-

-

... More
M&L Asbestos Rope including removal of existing unserviceable one compete all as specified and directed.

3

-

-

... More
M&L Water pump Assembly suitable for 7.5 KVA to 63 KVA DG set including removal of existing unserviceable one compete all as specified and directed.

3

-

-

... More
M&L Water pump Assembly suitable for 82.5 KVA to 125 KVA DG set removal of existing unserviceable one compete all as specified and directed.

2

-

-

... More
M&L Water pump Assembly suitable for 200 KVA to 500 KVA DG set including removal of existing unserviceable one compete all as specified and directed.

1

-

-

... More
M&L Feed pump suitable for 7.5 KVA to 63 KVA DG set including removal of existing unserviceable one compete all as specified and directed.

1

-

-

... More
M&L Feed pump suitable for 82.5 KVA to 125 KVA DG set including removal of existing unserviceable one compete all as specified and directed.

1

-

-

... More
M&L Electronic Type Starting Switch for 7.5 KVA to 15 KVA DG set including removal of existing unserviceable one compete all as specified and directed.

5

-

-

... More
M&L Electronic Type Starting Switch for 30 KVA to 125 KVA DG set including removal of existing unserviceable one compete all as specified and directed.

4

-

-

... More
M&L Servicing to oil fired incenerator of capacity 50 Kg/Hr with and including replacement of the worn out spares and cleaning nozzles of fuel injection, wet scrubber, proplet seperator with kerosene oil, ID fan blower including cleaning of Primary chamber, secondary chamber with replacement of unsv fire bricks if required, overhaling the motors, pumpsets and testing for smooth running complete all as manufacturer’s specifications and as directed (installed at 15 Mob, 180 MH )

2

-

-

... More
S&F Digital temperature indicating controller to read upto temperature 1200 degree centrigate with 2 set points including removal of existing unserviceable one in the control panel installed at 15 mobile vet hospital and 180 MH complete all as specified and directed.

1

-

-

... More
M&L primary burner as per existing installed at incenerator complete all as specified and as directed .

1

-

-

... More
M&L Secondary burner as per existing installed at incenerator complete all as specified and as directed .

1

-

-

... More
M&L Ignition transformer 230 Volts, 15 A , 50/60 HZ as per existing installed at incenerator complete all as specified.

2

-

-

... More
M&L Heat resistant canvas cloth used for the smoke duct as per existing installed at incenerator complete all as specified.

2

-

-

... More
M&L disconnecting Motor with ID fan casing of capacity 3HP from incenerator exhaust chimney pipe and carrying to work shop and rewinding the motor with appropiate guage supper enamelled copper conductor, varnishing, drying, replacement of bearings with new berings, worn out bushes, connectors, terminal plate and fixing back in original position, connecting cable through terminal block, including preperation of surfaces applying two coats of syntheic enamel paint of approved paint over a coat of red oxide primer and testing & commissioning complete all as specified & directed.

1

-

-

... More
M&L taking out unserviceable radiator from existing DG set of capacity 200 KVA to 400 KVA for servicing and cleaning by using chemical solution for removal of scaling/foreign material from water fins (tubes) through authorized dealer including checking and repair/replacement of water circulating pumps, thermostat, radiator cooling fan, all types of belts including soldring of damaged radiator fins and hose pipes for smooth functioning, complete all as specified and as directed.

4

-

-

... More
M&L taking out unserviceable radiator from existing DG set of capacity 62.5 KVA to 125 KVA for servicing and cleaning by using chemical solution for removal of scaling/foreign material from water fins (tubes) through authorized dealer including checking and repair/replacement of water circulating pumps, thermostat, radiator cooling fan, all types of belts including soldring of damaged radiator fins and hose pipes for smooth functioning, complete all as specified and as directed.

6

-

-

... More
M&L taking out unserviceable radiator from existing DG set of capacity 7.5 KVA to 45 KVA for servicing and cleaning by using chemical solution for removal of scaling/foreign material from water fins (tubes) through authorized dealer including checking and repair/replacement of water circulating pumps, thermostat, radiator cooling fan, all types of belts including soldring of damaged radiator fins and hose pipes for smooth functioning, complete all as specified and as directed.

8

-

-

... More
S&F battery low maintenance heavy duty lead acid of capacity 12 volts 150 AH suitable for DG sets including removal of existing unserviceable one compete all as specified and directed.

9

-

-

... More
S&F battery low maintenance heavy duty lead acid of capacity 12 volts 180 AH suitable for DG sets including removal of existing unserviceable one compete all as specified and directed.

10

-

-

... More
S&F battery low maintenance heavy duty lead acid of capacity 12 volts 200 AH suitable for DG sets including removal of existing unserviceable one compete all as specified and directed.

2

-

-

... More
Supply, Fixing and erection of Mild steel canopy Cover for SHIVAJI NAGAR DG set ( 82.5 KVA) as per existing size and profile duly painted with two coats of synthetic enamel paint over red oxide primer compete all as specified and directed.

1

-

-

... More
M&L Low oil pressure switch (LLOP) as per Existing OEM Suitable for upto 200 KVA DG sets capacity compete all as specified and directed.

3

-

-

... More
M&L microprossesor based fully configurated as per Existing OEM controller display panel board Suitable for upto 125 KVA DG sets capacity compete all as specified

2

-

-

... More
M&L Onload change over switch of capacity 63 Amps (Side handle) in sheet metal encloser, 415 V, 50Hz, 4 Pole compete all as specified and directed.

3

-

-

... More
M&L Onload change over switch of capacity 100 Amps (Side handle) in sheet metal encloser, 415 V, 50Hz, 4 Pole compete all as specified and directed.

3

-

-

... More
M&L Onload change over switch of capacity 400 Amps (Side handle) in sheet metal encloser, 415 V, 50Hz, 4 Pole compete all as specified and directed.

2

-

-

... More
M&L Onload change over switch of capacity 630 Amps (Side handle) in sheet metal encloser, 415 V, 50Hz, 4 Pole compete all as specified and directed.

1

-

-

... More
Scraping old paint of any capacity DG set Chessis (Approx coverage area 5-7 Sqm) installed at various locations and Painting with one coats of red oxide paint and two coat of synthetic enamel paint of shade compete all as directed.

4

-

-

... More
M & L earthing complete with copper Earth Plate Electrode 600mm x 600mm x 3.15mm, thick buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below Normal Ground Level, connected to GI earth strip 32X6 mm drawn through and including Galvanised Iron protection Pipe 40 mm bore (dia) Light grade by means of Bolts, Nuts, Check Nuts and Washers etc Earth plate surrounded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of not exc 150mm thick PCC Pit in cement concrete 1:3:6 (20 mm graded aggregrate ), Precast RCC 1:2:4 (20mm graded aggregrate ) cover slab 350 x350 x 50mm thick reinforced with and including 8mm dia TMT Bars @ 10 cm Centre to Centre both ways GI Wire Mesh , Funnel, with GI Watering Pipe 20mm bore dia Medium grade necessary excavation in soft loose soil returning filling in and removal of surplus soil upto a distance of 50 meter and all as shown in Electrical Plate No. 3 of MES schedule Part- I and testing on completion complete all as specified and as directed.

4

-

-

... More
M&L taking out all injector (by using right tools means torque wrench ) from DG set 200 KVA to 400 KVA for servicing through authorised dealar and refixing its original position after repairing including replacement of plunger, washer, jets and any internal parts of injector, complete all as specified and as directed.

1

-

-

... More
M&L taking out all injector (by using right tools means torque wrench ) from DG set 62.5 KVA to 125 KVA for servicing through authorised dealar and refixing its original position after repairing including replacement of plunger, washer, jets and any internal parts of injector, complete all as specified and as directed.

2

-

-

... More
M&L taking out all injector (by using right tools means torque wrench ) from DG set 7.5 KVA to 45 KVA for servicing through authorised dealar and refixing its original position after repairing including replacement of plunger, washer, jets and any internal parts of injector, complete all as specified and as directed.

2

-

-

... More
M&L fuel pipe ( benjo pipe) having length 1 feet to 3 feet of suitable size as per OEM including removal of existing unserviceable one compete all as directed.

12

-

-

... More
M&L Hause pipe of suitable size and length as per OEM for 62.5 KVA to 400 KVA including removal of existing unserviceable one compete all as directed.

10

-

-

... More
M&L contractor with add on accessories for AMF panel of suitable rating and exciting coil voltage 240/ 415 V as per OEM for 7.5 KVA to 45 KVA including removal of existing unserviceable one compete all as directed.

4

-

-

... More
M&L contractor with add on accessories for AMF panel of suitable rating and exciting coil voltage 240/ 415 V as per OEM for 62.5 KVA to 320 KVA including removal of existing unserviceable one compete all as directed.

4

-

-

... More
M&L contractor with add on accessories for AMF panel of suitable rating and exciting coil voltage 240/ 415 V as per OEM for 200 KVA to 500 KVA including removal of existing unserviceable one compete all as directed.

2

-

-

... More
Supply only Coolent suitable as per OEM suitable for DG sets compete all as directed.

20

-

-

... More
Supply only Engine OIL suitable as per OEM suitable for DG sets compete all as directed.

60

-

-

... More
M & L for periodic inspection/ servicing/ overhaulling of 10 Ton capacity flame proof EOT crane of any make installed at TP of 4 core OMC, making the cranes in serviceable condition complete all as specified and directed for maintenance specified as under:- (A) LONG TRAVERSE MOTION- (i) Checking gear box oil level, checking and rectification of leakage if any and filling with new oil up to required level. (ii) Checking functioning of all brakes of any capacity and making adjustment for proper working. (iii) Checking motion wheel for any abnormal sound & checking mounting/ fixing arrangement. (iv) Checking of grease in geared coupling and tighting of nut/bolts etc. (v) Checking of motion cut off at extreme ends with limit switches. (vi) Checking drive shaft and coupling including tighting of nut and bolts. (vii) Checking oil in FLP thrustors checking any leakage any filling with new oil. (viii) Checking terminal connection of all LT motion of three phase FLP electric motor and tightening properly including repalcing burnt out/ over heated cable ends if any. (B) CROSS TRAVERSE MOTION (i) Checking gear box oil level, checking and rectifiaction of leakage if any and filling with new oil up to required level. (ii) Checking functioning of all brakes of any capacity and making adjustment for proper working. (iii) Checking motion wheel for any abnormal sound & checking mounting/ fixing arrangement. (iv) Checking of grease in geared coupling and tighting of nut/bolts etc. (v) Checking of motion cut off at extreme ends with limit switches. (vi) Checking drive shaft and coupling including tighting of nut and bolts. (vii) Checking oil in FLP thrustors checking any leakage any filling with new oil. (viii) Checking terminal connection of all CT motion of three phase FLP electric motor and tightening properly including repalcing burnt out/ over heated cable ends if any. (C) HOIST MOTION (Item Contd.....)

4

-

-

... More
(a) Checking gear box oil level, checking and rectifiaction of leakage if any and filling with new oil up to required level. (b) Checking functioning of all brakes of any capacity and making adjustment for proper working. (c) Checking motion wheel for any abnormal sound & checking mounting/ fixing arrangement. (d) Checking of grease in geared coupling and tighting of nut/bolts etc. (e) Checking of motion cut off at extreme ends with limit switches. (f) Checking drive shaft and coupling including tighting of nut and bolts. (g) Checking oil in FLP thrustors checking any leakage any filling with new oil. (h) Checking terminal connection of all HT motion of three phase FLP electric motor and tightening properly including repalcing burnt out/ over heated cable ends if any. (D) ELECTRICALS (a) Checking and tightening all electric connection (b) Checking the contactors/ relays etc for overheating or flashing. (c) Cleaning off all connection and control cables. (d) Properly bunching the loose control cable. (e) Checking functioning of cable carriers. (f) Checking the connection and serviceability of VVVF drives for smooth (E) GROUND MOTION CONTROL PANEL Opening the push button control unit, checking all connection, replacing flashed/ over heated connections, general cleaning and checking all the functions,of the LT/CT/ Hoist motion push buttons and lights/ VVVF switch including reassembling the unit complete NOTE :-1. Any minor work Required for overhaulling/proper functining of EOT crane shall be included in unit quoted rate. . 2. Complete Greasing of each parts of crane for proper functining to EOT crane shall be included in unit quoted rate. 3. Gear box oil shall be measured and paid separately.

-

-

-

... More
All as per item No. 80 here-in-before but 5 ton capacity flame proof EOT crane complete all as specified and directed.

1

-

-

... More
All as per item No. 80 here-in-before but 5 ton capacity flame proof EOT crane installed at 4 Core zonal workshop complete all as specified and directed.

5

-

-

... More
All as per item No. 80 here-in-before but 3 ton capacity flame proof EOT crane installed at 41 R&O (LCH) complete all as specified and directed.

1

-

-

... More
Supply, fixing and making all connections for limit switch 40 Amps 415 Volts all as per existing for LT/CT/ hoist motion of 10/5/3 ton capacity crane including taking down unserviceable complete all as specified and directed.

2

-

-

... More
Supply only gear oil grade 680 suitable for hydraulic thruster brake complete all as directed.

20

-

-

... More
Supply and fixing brake liner set suitable for 100 mm dia drum for LT/CT motion of 10/5/3 ton capacity FLP crane inluding taking down unserviceable complete all as specified and directed.

2

-

-

... More
Supply and fixing brake liner set suitable for 160 mm dia drum for LT/CT motion of 10/5/3 ton capacity FLP crane inluding taking down unserviceable complete all as specified and directed.

2

-

-

... More
Supply and fixing torque springs suitable for 6 kg capacity 100 mm dia drum brakes of LT/CT motion, including taking out the old unserviceable complete all as specified and directed .

1

-

-

... More
Supply and fixing torque springs suitable for 9 kg capacity 160 mm dia drum brakes of LT/CT motion, including taking out the old unserviceable complete all as specified and directed .

1

-

-

... More
S&F Contactor 20 Amps with 2 NO + 2NC including taking out old unserviceable complete all as directed.

2

-

-

... More
S&F Contactor 25 Amps with 2 NO + 2NC including taking out old unserviceable complete all as directed.

1

-

-

... More
S&F Contactor 32 Amps with 2 NO + 2NC including taking out old unserviceable complete all as directed.

1

-

-

... More
M&L push button with element in push button box as per require colour code, including taking out old unserviceable one complete all as specified and directed.

5

-

-

... More
M&L brake shoe with disc of crane of capacity 10/5/3 ton as per existing one, including taking out old unserviceable one complete all as specified and directed.

4

-

-

... More
M&L Indicating Lamp as per required colour code, including taking out old unserviceable one complete all as specified and directed.

5

-

-

... More
M&L Hoist Rope Drum Bearing as per existing type and capacity including taking out old unserviceable one complete all as specified and directed.

1

-

-

... More
M&L LT/CT motor Bearing as per existing type and capacity including taking out old unserviceable one complete all as specified and directed.

3

-

-

... More
M&L Fuses (HRC) upto 40 Amps for EOT cranes as per existing type and capacity including taking out old unserviceable one complete all as specified and directed.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.