BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 1,31,800Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_671609_1Bid Award Id
ViewTender No
89800/SIL/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for Sub main wiring with two run of FRLS PVC insulated unsheathed multistranded copper conductor of nominal cross sectional area 2.5 Sqmm alongwith one run of FRLS PVC insulated unsheathed multistranded copper conductor of nominal cross sectional area 2.5 Sqmm as earth continuity conductor drawn through PVC conduit complete all as specified and directed by Engineer-in-charge.
NOTES :- (a) Two runs of cable, one run of earth wire with one run of PVC conduit/casing shall be measured as one length.
(b) All the incoming and outgoing cable should be connected through proper lugs and socket as per site requirements.
90
-
-
... More
Supply and fix single pole and neutral encloser with a two pin and earth plug and socket with one single pole MCB 16/25 Amp complete all as specified and directed by Engineer-in-charge.
12
-
-
... More
Supply and fix Plug(Top) 16/25 Amps 2P+E suitable for metal plug and socket complete all as specified and directed by Engineer-in-charge.
40
-
-
... More
Supply and fix Plug(Top) 16 Amps 3 pin (PNE) suitable for 15 Amp socket complete all as specified and directed by Engineer-in-charge.
50
-
-
... More
Supply and fix PVC rectangular box of mounting switch/socket/MCB DB's with 3 mm thick plastic laminated sheet cover of size 150x100x50mm deep complete all as specified and directed by Engineer-in-charge.
10
-
-
... More
Supply and fix switch socket combination 5A/16A, 5 in 1 flush type complete all as specified and directed by Engineer-in-charge.
10
-
-
... More
Supply, install, testing, commissioning and balancing of floating barge made out of MS steel plate, Angle iron along with super structiure suitable for hosing two Split casing electric driven centrifugal pump set of capacity 50 HP alongwith foundatioin of suitable size and flooring (plateform) of size 5x7 meter complete with provision of suction and delivery hole in the body structure with steel door, steel window, steel railing and stair case, including provision of manhole/inspection box on both sides of body structure for both pontoon duly painted with anti corrosive black bituminous paint in the pontoons and sky blue paint to the body and camouflaging paints of green and white on the roof top after de-galvanizing including all accessories and point wiring all as specified and directed by Engr-in-CHarge.
1
-
-
... More
Supply, instal, testing commissioning of horizontal split casing electric driven centrifugal pump of discharge capacity 140 cum m/hrs at 50 mtr head, multi stage, 150mm dia suction and 150mm dia delivery, coupled with 3 phase electric induction motor of 50 HP/37KW, 415 Volt, RPM 1450 totally enclosed fan ventilator type complete cast iron impellers and stainless steel shaft (coupled with flexible coupling) inclusive brass frame with min 50 Sqmm size of stranded copper wire copper lugs at both side of electric connection, as per manufacturer instruction complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
Supply and fix heavy duty armoured flexible corrugated rubber suction hose pipe of size 150 mm (bore) having both end heavy duty MS flange of suitable size complete all as specified and directed by Engineer-in-charge.
(Note: Maximum length of one piece of pipe should not be more than 6 meter with both end having MS flange)
42
-
-
... More
Supply, install , testing and commissioning of outdoor LT distribution feeder pillar box pedestal type (CPRI approved and with certification by ERDA for IP 65) of suitable size, factory made (tested as per IS) totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear, made out of 3.15mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly powder coated and Copper bus bar of 400 Amps, 415 volts, 50 Hz, 3 phase and 4 wired system, independently housing for each control switch gear and indicating lamps with & including busbars made of copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours. Bus bar shall be properly supported/mounted on epoxy insulators. All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitable earth strips. Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Grouting/fixed the pillar box in floating barge including suitable Nut-bolts system/Welding complete. Penal shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply. with the following items including supply and fixing with MS channel 75mm x 40mm x 5mm duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer for fixing the feeder piller box to foundation complete all as specified and directed by Engineer-in-charge. :-
In coming :-
(i)MCCB 4 Pole,415 V, Adjustable type, 160 Amps, breaking capacity 16 kA, Ics=100%Icu :- 01 No
1
-
-
... More
Contd of item No 12…..
OUTGOING :-
(a) MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 16KA, Ics=100%Icu - 02 Nos.
(b) 3Ph, Star delta Starter fully automatic suitable for 50 HP pump-motor set, 415 V, 50Hz AC having Single Phase, Overload, Phase reversal, Dry run, Phase Imbalance, Over & Under Voltage protection with following components:- 02 Set (i) 3-Pole, 415V, Power Contactor (for Star) Type - MNX70, Size-FR3, Cat No: CS97076 of Make: L&T or equivalent in list of makes. - 01 in Each set (ii) 3-Pole, 415V, Power Contactor (for Delta) Type - MNX95, Size-FR4, Cat No: CS94136 of Make: L&T or equivalent in list of makes - 02 in Each set (iii) Electronic Motor Protection Relay With in-built Earth Fault Protection 240V with thermal O/L range 32-88Amp, Model: MPR 300, Cat No: MPR305BE320 of Make: L&T or equivalent in list of makes - 01 in Each set (iv) Electronic Timers 240V, 50Hz for 3-30Sec, Type-ST 100, Cat No: ST80328OOOO of Make: L&T or equivalent in list of makes - 01 in Each set (v) Over Voltage & under voltage protection relay of Make-L&T or equivalent in list of makes - 01 in Each set (vi) 3-Ph, Digital Voltmeter 0-500 V with selector switch, Cat No: WL132020OOOO, Cl 0.5 of Make-L&T or equivalent in list of makes - 01 in Each set (vii) 3-Ph, Digital Ammeter 0-200 Amps with CTs and selector switch, Cat No: WL131020OOOO, Cl 0.5 of Make-L&T or equivalent in list of makes - 01 in Each set
(viii) Push Button (Red-Stop & Green-Start), Cat No: EP1FAC01 & EP1FAB02, Make-L&T or equivalent in list of makes - 01 in Each set (ix) LED Indicator Lamp 240V, 22.5mm (Green for ON&White for Trip) Set of 2, Cat No: EPL00000 Make: L&T or equivalent in list of makes - 01 in Each set (c) MCB DP 6-32 Amp, 10kA Cat No BB20060C-320C of Make: L&T or equivalent in list of makes - 01 No (d) MCB DP 40-63 Amp, 10kA Cat No BB20400C-630C of Make: L&T or equivalent in list of makes - 01 No. (e) Socket Outlet 15A with swich, Anchor - 02 Nos (f) 3-Ph, Digital Voltmeter 0-500 V with selector switch Cat No: WL132020OOOO, Cl 0.5 of Make-L&T or equivalent in list of makes - 01 No. (g) 3-Ph, Digital Ammeter 0-200 Amps with CTs and selector switch Cat No: WL131020OOOO, Cl 0.5 of Make-L&T or equivalent in list of makes - 01 No (h) LED Indicator Lamp 240V, (RYB) Set of 03, Cat No: EPL00000 Make-L&T or equivalent in list of makes - 01 Set. (j) Copper bus bar 4 strip (electro-plated with Copper) with min current rating 400Amp - 01 Set. (k) Spare - 01 No
Note :- Foundation will be icluded in quoted rate.
-
-
-
... More
Supply, install testing & commissioning of electric driven vertical turbine pump of discharge head 15 mtr, 1460 RPM, 4 stage bowl brass impeller BRZ, line shaft SS-410, impeller shaft SS-410, shaft sleeve SS-410, bpwl bearing as per standard, column pipe-mild steel flange end (MS), depth of well considered 20 mtr with electric induction motor, vertical hollow shaft, SPDP, squirrel cage induction motor, 30HP/22 KW, 1500 RPM frame size SVH-180, 415 + 50Hz, 3 Phase AC with 35 Sqmm size of copper wire for electric connections as per manufacturer instruction & directed by Engr-in-Charge complete all as specified and directed.
1
-
-
... More
Supply and Fix MS pipe 'C' Class, Heavy duty conforming to IS-1239, Part-I (2004) including cutting for suitable size as directed, specials Tread with sockets or heavy duty MS flange, MS Nut-Bolts on both end for nominal dia 150 mm all as specified and directed by Engr-in-Charge. [Note: Max length of one piece of pipe should not be more than 1.8 metre (6 feet) having both the end heavy duty MS flange with min 6 Nos of hole for nut-bolts] complete all as specified and directed by Engineer-in-charge.
20
-
-
... More
Supply and install electrical induction motor vertical type 3 HP, 3Phase, 440 Volt 50Hz.complete all as specified and directed by Engineer-in-charge.
1
-
-
... More
All as per Srl Item No 15 here-in-before but for 1.5 HP.
1
-
-
... More
All as per Srl Item No 15 here-in-before but for 1 HP.
3
-
-
... More
Supply and fix Star delta Starter fully automatic suitable for 415 V AC for 30 HP motor of VT pump with single phase preventor complete all as specified and directed by Engineer-in-charge.(Model No : MU-G40 FASD(with wideband coil) of make L&T cat No CS90908 or equivalent in list of makes)
1
-
-
... More
Supply and fix DOL Starter suitable for 415 V AC for 3HP motor pump-set complete all as specified and directed by Engineer-in-charge.(Model No : MF1 three phase starter of make L&T cat No SS97210O or equivalent in list of makes)
1
-
-
... More
Supply and fix DOL Starter suitable for 415 V AC for 2HP motor pump-set complete all as specified and directed by Engineer-in-charge.(Model No : MF1 three phase starter of make L&T cat No SS97210O or equivalent in list of makes)
4
-
-
... More
Supply and fix CI foot valve suitable for 150 mm dia pipes complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
Supply and fix Sluice Valve flange of class PN-1.6, brass spindal of size 150mm, ISI marked heavy duty for DI pipe confirming the testing standerd as per IS : 14846 and fixed completely in location all as specified and directed by Engineer-in-charge.
3
-
-
... More
Supply and fix Non Return Valve flange of class PN-1.6 of size 150mm, ISI marked heavy duty for DI pipe confirming the testing standerd as per IS : 14846 and fixed completely in location all as specified and directed by Engineer-in-charge.
2
-
-
... More
Supply and fix high quality steel rope with PVC coated of size 25mm for holding the river barage complete all as specified and directed by Engineer-in-charge.
1000
-
-
... More
Supply and fix high quality 'U' clamp with nuts of size 25mm for holding the river barage complete all as specified and directed by Engineer-in-charge.
16
-
-
... More
M&L for Earthing complete with GI plate Electrode of size 60 Cm X 60 Cm X 6 mm thick burried directly in ground vertically at a depth not less than 2.25 metre below normal ground level, with top edge of earth plate at a depth not less than 1.5 metre. below normal ground level , connected to galvanised iron strip of size 32 X 6 mm earth lead by means of bolts, nuts and washers of galvanised iron , earth lead strip protected by means of 40 mm bore dia light grade GI pipe up to switch board / panel board and 20 mm bore galvanised iron pipe medium grade for watering with GI funnel and wire mesh , all as specified and shown in MES schedule Electrical Plate No:-3 of SSR Part I, including excavation and earth work in any type of soil , PCC 1 : 3 : 6 type C1 in chamber , RCC 1:2:4 type B1 50 mm thick cover slab with 6 mm dia MS bars at 100 mm centre to centre both ways, and provision of 6 mm dia MS hook, Charcoal and common salt in alternate layers complete and testing the earth resistance and writing on the chamber by paint complete all as specified and directed by Engineer-in-charge.
10
-
-
... More
M&L for Earthing complete with Copper plate Electrode of size 60 Cm X 60 Cm X 3.15 mm thick burried directly in ground vertically at a depth not less than 2.25 metre below normal ground level, with top edge of earth plate at a depth not less than 1.5 metre. below normal ground level , connected to copper strip of size 20 X 3 mm earth lead by means of bolts, nuts and washers of galvanised iron , earth lead strip protected by means of 40 mm bore dia light grade GI pipe up to switch board / panel board and 20 mm bore galvanised iron pipe medium grade for watering with GI funnel and wire mesh , all as specified and shown in MES schedule Electrical Plate No:-3 of SSR Part I, including excavation and earth work in any type of soil , PCC 1 : 3 : 6 type C1 in chamber , RCC 1:2:4 type B1 50 mm thick cover slab with 6 mm dia MS bars at 100 mm centre to centre both ways, and provision of 6 mm dia MS hook, Charcoal and common salt in alternate layers complete and testing the earth resistance and writing on the chamber by paint complete all as specified and directed by Engineer-in-charge.
6
-
-
... More
Supply, laying & testing cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq. mm 3.5 Core complete all as specified and directed by Engineer-in-charge.
100
-
-
... More
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,
manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil.
2
-
-
... More
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m but n exc 3.0 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and exc 1.5 m but n exc 3.0 m in depth and getting out in soft/loose soil.
2
-
-
... More
Returning filling in including spreading, levelling, watering well ramming in layers not exc. 25cm thick complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
Removing excavated material(Soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
3
-
-
... More
M&L for concrete as in foundations of pumps and machinery/copping of electric pole type B-1, 1:2:4 with 20mm graded aggregate complete all as specified and directed by Engr-in-Charge.
4
-
-
... More
M&L for plastering 15mm thick in cement mortar (1:4) on fair face of brick masonry (Brick piller) or concrete surface and finishing the surface even and smooth without using extra cement.
4
-
-
... More
M&L for MS clamps, angle, MS flat iron and nuts, Bolts and washers including necessary welding work complete all as specified and directed by Engr-in-Charge.
40
-
-
... More
Supply, installation, testing and commissioning of vacuum circuit breaker 11KV, 800Amp, 26.3kA, for 3-Sec horizontal Drawout/Horizontal isolation VCB fitted with motor operated mechanism with 240V AC motor, closing 24V DC, tripping 24V DC aux, contactor 6NO+6NC mechanical ON/OFF indicator, push button mechanical operation counter with inbuilt mechanism anti pumping feature handle set for rackin/out spring charge and on/off including neccessary foundation with following component of Make: Schneider or equivalent in list of makes:-
(A) Moving Part:-
(i) VCB enclosure + connection -(For Incoming Panel 01 No & for Outgoing panel 01 No) , (ii) 800A PVC sleeved copper Busbar-(For Incoming Panel 01 No & for Outgoing panel 01 No), (iii) Side entry with connection - (For Incoming Panel 01 No & for Outgoing panel 01 No) (iv) Castel key interlock(Electrical + Mechanical) : (For Incoming Panel 01 No)
(B1) CTR : 100-50/5+5A (For Incoming Panel 03 Nos & for Outgoing panel 03 Nos)
(i) Core-1, CI-0.5, 15VA, (ii) Core-2 CI-5P10, 15 VA
(B2) Three phase potential transformer (For Incoming Panel 01 No)
(i) 11KV/RT3/110V/RT3, CORE-1- 100VA,CL-0.5
(C) BREAKER PANEL INDICATION LAMP (i) Breaker ON/Off/Trip ckt healthy/spring charged/Auto trip induction breaker test position/Breaker Service position/power pack test-(For Incoming Panel 08 Nos & for Outgoing panel 07 Nos)
(ii) Phase indicating Red ph/Yellow ph/Blue ph-(For Incoming Panel 03 Nos)
3
-
-
... More
Contd of item No 36...
(D) Switches gear and other accessories:-
(i) Heater with heater Switch & Thermostat -(For Incoming Panel 01 No & for Outgoing panel 01 No), (ii) Cubical Illumination Lamp -(For Incoming Panel 01 No & for Outgoing panel 01 No) (iii) 15A, 230V, AC 3pin Plug with Socket-(For Incoming Panel 01 No & for Outgoing panel 01 No) (iv), Breaker control switch(close neutral trip)-(For Incoming Panel 01 No & for Outgoing panel 01 No), (V) 2P, 16A AC swich-(For Incoming Panel 01 No & for Outgoing panel 01 No), (vi) 3P, 16A, DC switch-(For Incoming Panel 01 No & for Outgoing panel 01 No) (vii) Aux Contactor-(For Incoming Panel 01 No)
(E) Meters :- (i) 96 Sq mm 1Ph digital Ammeter with selector switch-(For Incoming Panel 01 No & for Outgoing panel 01 No), (ii) 96 Sq mm 1 Ph digital Voltmeter with selector switch-(For Incoming Panel 01 No) (iii) Digital Multifunction Meter 3 Ph 4 Wire CL.-1.0 WITH RS485 (ELITE-445 or equvalent in list of makes)-(For Incoming Panel 01 No & for Outgoing panel 01 No)
(F) Relay : (i) Neumerical relay without Comn(50-51/50N-51N,95)-(For Incoming Panel 01 No & for Outgoing panel 01 No), (ii) Master trip Relay(86)(AVAJH13/EQV) -(For Incoming Panel 01 No & for Outgoing panel 01 No, (iii) Transformer protection(74)(AVA33/EQV-(for Outgoing panel 02 Nos, (iv) Antipumping Relay(94)-(For Incoming Panel 01 No & for Outgoing panel 01 No, (v) 8W- Annunciator-(for Outgoing panel 01 No), (vi) 110VA C healthy Relay(69)-(for Outgoing panel 01 No), (vii) Power pack (110V AC to 24V DC)-(For Incoming Panel 01 No)
(G) Control Fuse :- (i) Control Fuse(4A)-(For Incoming Panel 02 No & for Outgoing panel 02 No, (ii) Control Fuse(10A)-(For Incoming Panel 08 No & for Outgoing panel 05 No), (iii) Link 16A-(For Incoming Panel 02 No & for Outgoing panel 02 No), (iv) Push button for emergency trip-(For Incoming Panel 01 No & for Outgoing panel 01 No), (v) Push button for PP test - (For Incoming Panel 01 No), (vi) Buzzer-(For Incoming Panel 01 No)
-
-
-
... More
Supply, install , testing and commissioning of outdoor LT distribution feeder pillar box pedastal type (CPRI approved and with certification by ERDA for IP 65) of suitable size, factory made (tested as per IS) totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear, made out of 3.15mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly powder coated painting and Copper bus bar of 630 Amps, 415 volts, 50 Hz, 3 phase and 4 wired system, independently housing for each control switch gear and indicating lamps with & including busbars made of copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours. Bus bar shall be properly supported/mounted on epoxy insulators. All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitable earth strips. Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories.Grouting/fixed the pillar box in ground with including suitable size of foundation & plinth with min height 45cm of PCC 1:3:6 type C1 using 20mm graded stone aggregate including suitable Nut-bolts system/Welding complete. Penal shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply. with the following items including supply and fixing with MS channel 75mm x 40mm x 5mm duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer for fixing the feeder piller box to PCC foundation complete all as specified and directed by Engineer-in-charge. :-
In coming :-
(i)MCCB 4 Pole, 415 V adjustable type 400 Amps, braking capacity 36 kA, Ics=100% Icu- 1 No
Out going :- (i)MCCB 4 Pole, 415 V adjustable type 160 Amps, breaking capacity 16 kA, Ics=100% Icu- 2 Nos
(ii) MCCB 4 Pole, 415 V adjustable type 125 Amps, breaking capacity 16 kA, Ics=100% Icu- 1 Nos
(iii)MCCB Four Pole, 415 V adjustable type,100Amps, breaking capacity 16 kA, Ics=100% Icu - 1 No.
(iv) 3-Ph, Digital Voltmeter 0-500 V with selector switch - 01 No.
(v) 3-Ph, Digital Ammeter 0-200 Amps with CTs and selector switch - 01 No
(vi) Phase indicator lamps 240V LED Type (RYB) set of 3 - 01 Set
(vii) Copper bus bar 4 strip (electro-plated with Copper) with min current rating 630Amp - 01 Set (VII) Spare - 01 No
Note :- PCC for foundation and earthwork will be icluded in quoted rate.
1
-
-
... More
Testing and commissioning only 125 KVA DG set (Make ASHOL LEYLAND, Engine model & Type : AL6DTIDG, Sl NO : NEHMH13864) including pre-commissioning, service and repair/replacement of display panel complete all as specified and as directed.