Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 76,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_661800_2Bid Award Id
ViewTender No
CWE/TEZ(N)/T-13 of 24-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Removing excavated material / soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
10.94
-
-
Supply and lay fine sieved excavated dry soil cushioning spreading levelling for cable trenches all as specified and directed (Punned thickness only shall be measured and paid)
7.49
-
-
Supply and laying Supplying and laying reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete
555
-
-
Supply & Lay in trenches XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sq. mm 3 core complete
185
-
-
S & L trenches /fixed on walls by suitable clamps and jointing complete GI pipe 100 mm light grade complete
20
-
-
S & F for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size
50
-
-
Supply and fix in repairs out door type cable end termination joint heat shrinkable type for HT XLPE 11000 volt grade cable of size 95 sqmm 3 core and connecting the cable with the load and testing including earth work complete all as specified and as directed for the following size of the cable.
Note : Excavation shall be measured and paid separatly under relevant item here in after
6
-
-
Supply and fix in repairs indoor type cable end termination joint heat shrinkable type for HT XLPE 11000 volt grade cable of size 95 Sqmm 3 core and connecting the cable with the load and testing complete all as specified and as directed for the following size of the cable.
Note : Excavation shall be measured and paid separatly under relevant item here in after
3
-
-
Supply and fix cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 Sqmm Indoor/Outdoor type complete all as directed.
2
-
-
Supply and fix cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 Sqmm Indoor/Outdoor type complete all as directed.
2
-
-
M&L for painting of indoor HT panel of any size with two coats of synthetic enamel grey colour paint after throughly scrapping/cleaning the rushed portion and fixing the HT panel door properly including welding work if necessary and miscelleneous items complete all as specified and directed by Engr-in-Charge
Note :- (i) Rate quoted to be inclusive of writing the MES No , Name of equipment and Name of feeder.
250
-
-
Material and labour for taking out bottom trolly of HT VCB11 KV 630 Amps capacity after disconnecting power supply and carrying out servicing and maintenance of operating mechanism, latch assembly spring mechanism, checking of electrical control wiring of VCB and checking for proper functioning of shunt trip coil, lubricating of all moving parts and checking /cleaning of alignment of moving contacts with fixed contact assembly for proper functioning of operation. Reassembling of bottom trolly of HT VCB fixed in its original position and testing for smooth functioning complete all as specified and as directed by Engr-in- charge
4
-
-
M & L for calibration of IDMT relays set of three through relay test kit inlcuding other required measuring equipment to the site by secondary injection method and testing for proper functioning/tripping systems of relays complete all as specified and as directed. Note : 1. The rate quoted by the contractor is deemed to be included for quarterly checking of relays in VCB for its proper setting/fuctioning and tripping of VCB during over load/earth fault.
2. Rep details from authorised coy and dealer not accepted local machenic
4
-
-
Supply and fixing in replacement of HT current transformer of capacity for suitable to the ratio 100/5A three phase and four wire including testing commissioning of through primary injection method with suitable testing kit and also checking the control panel wiring including setting the CT range with relays setting for proper functioning/tripping and taking out old unserviceable CT complete all as specified and as directed.
9
-
-
Supply and fixing in replacement of big and small end bearing of HT 11 KV VCB trolly including replacement of complete locking mechanism with integral spring charging handle for manual spring charge and replacement of closing coil and triping coil 24V DC including replacement of electro magnetic relay, coil rating 220 V, AC of existing sample.
3
-
-
Supply and fixing in replacement resin encapsulated vacuum interrupter bottles of the same manufacturers as per existing circuit breaker trolley of 11 KV.
9
-
-
Supply and fix in replacement of spring charge universal motor suitable for 11 KV, VCB,working on 230 volt of existing make all as specified and directed.
5
-
-
Supply and fixing in replacement of current transformer moulded in epoxy compound with dual ration capacity for suitable to the existing rating complete connection with copper wire including beading as per existing VCB 11 KV at site all as specified and directed by Engr-in charge.
3
-
-
S&F for gang Operated device 11 KV Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps complete
4
-
-
Supply & fixing 11KV lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp complete and incl taking down the old items.
4
-
-
S& F Horn gap fuse unit assembly tripple pole outdoor type suitable for HT 11 KV up to 400 Amp complete
4
-
-
M&L alu Painting to two pole structure HT of 11 Mtr long incl fittings and fixtures and cross arms complete, fixed with poles with two coats of alluminium paint incl scrapping of rusts and preparation of surfaces etc., complete all as specified and as directed by Engr-in-Charge.
4
-
-
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. Complete
24
-
-
S& F for chequered Plates 410 w ( Gde -E250 ) quality A , channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed
50
-
-
Material and labour for finding out the cable fault of any size of cable upto 11 KV underground cable (HT of any capacity of cable with the help of cable fault loacator mounting on vehicle and with nessary disconnection of cable from two ends and making connection by joing after repairs and having the following items with electrician at site to find fault of up to length of 10 KM cable complete all as specified and directed by Engr-in-Charge with help of the following accessores- (a) Surge Generator with accessories
(b) Head Phone
(c) Pin Point Set T-505 with accessories
(d) Earthing cable with clamp (e) Cable fault Locator T-905 with accessories (f) TC-808 with accessories (g) Soldering Iron/wire/capacitor unit/capacitor connecting cables/ power cable/nose plier. Notes: Excavation for the cable fault shall be done by the contractor by his own arrangement.
1
-
-
Supply and fix in replacement Digital Voltmeter, 11 KV, of site for suitable to the existing size including taking down the existing one all as specified and as directed.
4
-
-
Supply and fix in replacement MD XL type 10 KVAR to 20 KVAR capacitor 440 volt, 3 Phase, , voltage test between terminals 1.75 rated volt including taking out u/s all as directed by Engs-in -charge.
4
-
-
S&L for insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green and two-in-series' assembly for tension with tension clamps for conductors, working pressure 11000 volts complete complete all as specified and directed by Engr-in charge
25
-
-
S& F for GLS type Bulb 500 watts 230 volt for heating for VCB to control moisture complete all as specified and directed
50
-
-
Supply and lay sand cushioning spreading levelling for cable duct at sub station complete all as specified and directed
50
-
-
M&L for online centrifuging (filtration/ dehydration) of transformer oil including checking di-electric strength of oil before and after filtration for transformers with suitable machine having filtration, heating and pumping facility to improve the dielectric strength/ insulation value of oil.
Notes :- (i) Di-electric strength of oil after filtration/ dehydration shall not be less than 60 KV/min.
(ii) The contactor shall take shut down orders in writing from Engineer-in-charge before commencement of the work.
(iii) The contractor shall ensure no wastage of transformer oil. (iv) The di-electric strength of oil shall be tested before & after filtration and test results shall be submitted to Engineer-in-Charge.
7500
-
-
Supply and filling new transformer oil for topping up the transformers duly filtered with filtration plant having dielectric strength not less than 60 KV complete all as specified and as directed. Note :-
(a) The transformer oil shall be type EHV confirming to IS - 335/1983.
(b) Mineral oil grade shall be used.
(c) The IR value of transformer oil shall not be less than 60KV/min.
(d) The unit rate shall be deemed to include the cost of filtration to achieve desired di-electric strength.
1100
-
-
Maintenance/servicing of existing transformer of cap up to 400 KVA including follwing work/operations all as directed and to the entire satisfaction of Engr-in-Charge :-
(a) Opening of top plate after disconnection from HT/LT side. (b) Decaning of old transformer oil & keeping it for reuse after centrifusing to required dielectric strength as per IS schedules
(c) Checking maintenance of all internal parts as HT/LT coils of all places, HT bushing, internal electrical connections, tap changing gear box.
(d) Internal cleaning of tank by taking of complete coil/core of transformer outside and also cleaning of cooling tubes and make it free from sludge deposition.
(e) Refilling of oil after repairs / maintenance work.
(f) Change of cork Gasket of top cover.
(g) Taking meggar value by applying not less than 5000 Volts meggar on HT side and not more than LT side from 500 Volts meggar & recording results.
(h) Change of silica gel and glass of oil level indicator of cover both.
3
-
-
Dismantling and removing of defective transformer removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and assembling complete in all respects after repair/ replacement of coils, gasket, sheet, nuts and bolts, refilling of transformer oil, installation and testing on full load for testing for 11 KV capacity from 100 to 400 KVA complete all as specified and directed by the Engr-in-Charge.
Items No 41 & 42 Note: 1. Spare parts and winding coils as mentioned under respective items of schedule shall be measured and paid for separately as supply only. These shall be identical to those specified by original manufacturer. 2. The Maint /service work to be carriod out in factory permises, the cost quoted deemed to included liftings, transporting of Transformer from site to factory and back including reinstalling testing complete.
3
-
-
Material and labour for rewinding the LT/HT side (primary winding/Secondary windings) of the transformer with copper winding (wire/strip )of suitable gauge or to match the existing including refixing, connecting, testing and commissioning the transformer complete.
320
-
-
Supply and fix in repair HT bushing rod complete with insulator and packing suitable for out door/Indoor type 100 KVA to 400 KVA transformers confirming to IS-334 complete with nut bolts brass studs and gasket of synthetic rubber bonded cork sheet all as specified and directed by Engr-in-Charge.
10
-
-
Supply and fix in repair LT bushing complete with insulator and packing suitable1100 volt grade complete with nut bolts, brass studs, insulator and gasket etc suitable for100 KVA to 400 KVA out door/Indoor transformer. Notes for above item No 1. Rates quoted by the contractor shallbe deem to include for opening of top plate of transformer/decanning of oil from transformer up the level as per requirement and assemble the same after replacement of bushing rod.
2. Bushing rod shall be replaced at site. transformer will not be allowed to send to workshop at any cost and all bushing replacement work shall be executed at site only.
10
-
-
Supply and fix air breather complete with silica gel suitable for out door type step down power transformer up to 100 KVA to 400 KVA all as specified and directed by Engr-in-Charge.
10
-
-
Material and labour for spray painting of distribution transformer with two coats of synthetic enamel paint of smoke grey colour after neatly cleaning and preparing the surface for spray painting the transformer of the following capacity including writing SM / MES No (5 cm height) with white enamel paint of cap 100 KVA to 400 KVA complete all as specified and as directed.
10
-
-
Supply and fill in replacement of silica gel in transformer complete all as directed
10
-
-
Supply and fix in replacement of Temp gauge in transformer breather complete all as directed
10
-
-
S&F MCCB adjustable thermal & magnetic setting 415V, 3 pole, 50Hz of capacity 125 Amps 16 KA including taking out old u/s one
2
-
-
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 160 Amps 36 KA including taking out old u/s one
1
-
-
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 200 Amps 36 KA including taking out old u/s one
2
-
-
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 250 Amps 36 KA including taking out old u/s one
4
-
-
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 350 Amps 36 KA including taking out old u/s one
3
-
-
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 400 Amps 36 KA including taking out old u/s one
5
-
-
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 500 Amps 36 KA including taking out old u/s one
4
-
-
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 630 Amps 36 KA including taking out old u/s one
2
-
-
S&F for Steel tubular swaged poles with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 ( 9 metres long) applying one coat of synthetic enamel paint and including taking down with excavation and PCC complete all as specified and directed by Engr-in-Charge
10
-
-
S& F for GI earthing strip 25x4 mm with nut and bolts comoplete including taking down old one all as specified and directed by Engr- in- Charge
157
-
-
S&F of GI Strip ISI marked of size 32 x6 mm complete with nuts, bolts and washers,buried in ground including excavation complete all as specified and directed by Engr-in-Charge.
150
-
-
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground( earth pit not less than 2.25 m deep below the normal groungnd level) with top edgee of the plate not less than 1.5m below normal GL connected to GI earth strip of size 25x4mm by means of bolts, nuts, check nuts washers of GI or steel all as shown in electrical plate No-5 of SSR Part I connected to machanery/equipments installed power house/sub station all as specified including testing on completion.
Note No-1 the unit rate shall also include for excavation earth work in any type of soil PCC (1:3:6) type C1 pit RCC 1:2:4 type B-1 cover reinforced with 8 mm dia CTD bars @ 150mm C/C both ways funnel with 15mm bore GI watering pipe 20mm dia bore GI protection pipe wire mesh and copper lugs complete in addition to item No 1(a) to (e) of preamble ( Notes) Under sub heading earthing specified on SI page NO-389 of SSR Part-II 2004.
15
-
-
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground( earth pit not less than 2.25 m deep below the normal groungnd level) with top edgee of the plate not less than 1.5m below normal GL connected to GI earth strip of size 32x6 mm by means of bolts, nuts, check nuts washers of GI or steel all as shown in electrical plate No-5 of SSR Part I connected to machanery/equipments installed power house/sub station all as specified including testing on completion.
Note No-1 the unit rate shall also include for excavation earth work in any type of soil PCC (1:3:6) type C1 pit RCC 1:2:4 type B-1 cover reinforced with 8 mm dia CTD bars @ 150mm C/C both ways funnel with 15mm bore GI watering pipe 20mm dia bore GI protection pipe wire mesh and copper lugs complete in addition to item No 1(a) to (e) of preamble ( Notes) Under sub heading earthing specified on SI page NO-389 of SSR Part-II 2004.
20
-
-
NOTES:
1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.
2. The rates for RCC/PCC shall deemed to include the cost of formwork, shuttering etc., required for complete and proper execution of the item. Refer Schedule "A" notes for details.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements