Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Oct 2024
Closing Soon26 Nov 2024
Tender Amount₹ 29,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes

52.65

-

-

... More
Supply and laying burnt bricks of sub-class 'B' of size 230x115x75mm laid in trenches for cable protection complete all as specified and as directed

4801

-

-

... More
M&L for taking down carefully post top lantern / street light of any capacity / any make after disconnecting electric connections and carrying out repairs by replacing worn out / burnt / damaged parts / components and refixing the same after carrying out necessary repairs to original place, complete all as specified and as directed Note: Replaced major parts / components will be measured under respective items hereunder and minor spares viz. glands, nuts, bolts, etc. shall be deemed to be included in quoted rate

177

-

-

... More
Fixing only street light fittings/ flood lights after repair of any wattage on wall/poles, any height comprising of LED drivers , Surge protection with cables suitable for mounting on 40 mm to 50mm GI pipe or bracket arms with pole fixing attachments and other connected accessories duly prewired with copper conductor inlcuding complete testing, complete all as specified and as directed.

25

-

-

... More
M&L for dismantling and taking down old unserviceable junction boxes of any type /size from any location / position and disposing off including all necessary carting, etc. complete all as specified and as directed

21

-

-

... More
M&L for taking out old UNSV cable from trenches of any sizes, complete all as specified and as directed.

650

-

-

... More
M&L for DK thermoplastic cable junction boxes IP 65 of size 140x140x95 of metric knock outs for cable entry , weather proof for outddor installation and including glands and with 4 terminals for terminating one incoming and out going UG cable of size 10/16 sqmm 2/4 core and fixed to the PSC/ steel poles by means of suitable size clamps with nut and bolts , complete all as specified and as directed

21

-

-

... More
M&L for plain cement concrete 1:3:6 (type C-1) using 20mm graded stone aggregate as in foundations, mass concrete, etc. complete all as specified and as directed

3

-

-

... More
S&F LED street light 60W with 10kV SPD, pressure die cast aluminium housing with polycarbonate cover and high power LEDs and secondary lenses with IP-66 protection having efficiency 110 LPW /125LPW, mounting on existing bracket with all fixing arrangement as required on any size of pole including taking down old unserviceable light fittings and disposing off complete all as specified and as directed

10

-

-

... More
S&F LED street light 70W with 10kV SPD, pressure die cast aluminium housing with polycarbonate cover and high power LEDs and secondary lenses with IP-66 protection having efficiency 110 LPW /125LPW, mounting on existing bracket with all fixing arrangement as required on any size of pole including taking down old unserviceable light fittings and disposing off complete all as specified and as directed

8

-

-

... More
S&F LED street light 90W with 10kV SPD, pressure die cast aluminium housing with polycarbonate cover and high power LEDs and secondary lenses with IP-66 protection having efficiency 110 LPW /125LPW, mounting on existing bracket with all fixing arrangement as required on any size of pole including taking down old unserviceable light fittings and disposing off complete all as specified and as directed

6

-

-

... More
S&F LED street light 100W with 10kV SPD, pressure die cast aluminium housing with polycarbonate cover and high power LEDs and secondary lenses with IP-66 protection having efficiency 110 LPW /125LPW, mounting on existing bracket with all fixing arrangement as required on any size of pole including taking down old unserviceable light fittings and disposing off complete all as specified and as directed

2

-

-

... More
S&F LED street light 120W with 10kV SPD, pressure die cast aluminium housing with polycarbonate cover and high power LEDs and secondary lenses with IP-66 protection having efficiency 110 LPW /125LPW, mounting on existing bracket with all fixing arrangement as required on any size of pole including taking down old unserviceable light fittings and disposing off complete all as specified and as directed

2

-

-

... More
Supply only drivers for LED street lights of capacity 70W/60W, 230 volts , 50 Hz , complete all as specified and directed.

10

-

-

... More
Supply only Surge protection devices for 10KV suitable for LED street lights of any capacity as per required, complete all as specified and directed.

4

-

-

... More
S&F 300W LED flood light fitting, pressure die cast aluminium housing with heat resistant toughened glass, IP-66 protection luminaries with 300W LED lamp including taking down old / unserviceable fitting and disposing off complete all as specified and as directed

3

-

-

... More
S&F 210W LED flood light fitting, pressure die cast aluminium housing with heat resistant toughened glass, IP-66 protection luminaries with 300W LED lamp including taking down old / unserviceable fitting and disposing off complete all as specified and as directed

2

-

-

... More
S&F 170W LED flood light fitting, pressure die cast aluminium housing with heat resistant toughened glass, IP-66 protection luminaries with 300W LED lamp including taking down old / unserviceable fitting and disposing off complete all as specified and as directed

8

-

-

... More
S&F 120W LED flood light fitting, pressure die cast aluminium housing with heat resistant toughened glass, IP-66 protection luminaries with 300W LED lamp including taking down old / unserviceable fitting and disposing off complete all as specified and as directed

2

-

-

... More
S&F 100W LED flood light fitting, pressure die cast aluminium housing with heat resistant toughened glass, IP-66 protection luminaries with 300W LED lamp including taking down old / unserviceable fitting and disposing off complete all as specified and as directed

8

-

-

... More
Supply only drivers for LED floodt lights of capacity 90W/120W, 230 volts , 50 Hz , complete all as specified and directed.

5

-

-

... More
S&F Coral (Opal) IP 65 New Generation 25 W post Top energy saving , environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source , complete all as specified and as directed.

4

-

-

... More
S&F Heriatge LED IP 65 20 W post Top idealto light up parks, garden ways and heritage sites,energy saving , environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source , complete all as specified and as directed.

2

-

-

... More
S&F LED lignt 10 W MAYA II , pressure ide cast powder coated housing with PC diuffuser and efficient high output LED with IP 66 protection, complete all as specified and as directed.

25

-

-

... More
S&F LED step light 07 W Radiant , pressure ide cast powder coated housing with PC diuffuser and efficient high output LED with IP 65 protection, complete all as specified and as directed.

20

-

-

... More
S&F Moon (Opal) LED light 9 W decorative gate light made up of high grade unbreakable polycarbonate material suitable for 9 LED bulb, complete all as specified and as directed.

75

-

-

... More
S&F in repairs steel water tubing, 40mm bore, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or floors for mounting of post top lanterns, cut to required length of 1.5m long (each) duly grouted in ground complete all as specified and as directed

18

-

-

... More
M&L for cross arms, bracings, supports clamps, and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated and inclusive of one primer coat, one under coat and one finishing coat of good quality of aluminium paint all as specified and as directed

0.5

-

-

... More
Supplying, fabricating and fixing bracket suitable for hanging light fittings in 40mm bore GI tubing, light grade, cut and bent to shape required, 1.5m long, flat iron clamp made of FI 40x6mm, nuts, bolts, washers, etc. duly painted with two coats of aluminium paint over a coat of red oxide zinc chrome primer including taking out old damaged brackets and disposing off complete all as specfied and as directed

18

-

-

... More
S&F PVC insulated , PVC sheathed cable with stranded copper conductor of size 1.5 sqmm 3 core , 1100 volts grade, complete all as specified and as directed.

100

-

-

... More
Supply, laying, jointing, connecting and testing XLPE insulated PVC sheathed cable 1100V grade, screwed PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands including taking out/down old unserviceable cable and disposing off complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective item herein

-

-

-

... More
25 sqmm 3.5 core

100

-

-

... More
16 sqmm 4 core

200

-

-

... More
10 sqmm 4 core

300

-

-

... More
10 sqmm 2 core

50

-

-

... More
S&F in repairs non-metallic rigid PVC conduit 20mm bore with accessories complete all as specified and as directed

90

-

-

... More
M&L for cutting unwanted growth of plants, vegetation, weeds, shrubs, small trees, bushes, etc. from inside / outside surrounding of installations / reservoirs, etc. and brooming off and removing rubbish to a distance not excceeding 50m complete all as specified and as directed

2500

-

-

... More
Supply, installation, commissioning and testing CPRI approved LT feeder pillar box, outdoor type of suitable size recommended by CPRI approved manufacturer, cubical floor mounted type (IP-65 degree of protection) made out of 3.15mm thick powder coated CRCA sheet , with aluminium strip bus bar 200A rating duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415V 50Hz AC supply, including cable entry boxes, cable gland, with 50x50x6mm angle iron supports, bottom portion duly grouted in PCC foundation as per manufacturer's instructions totally tested as per IEC 61439-I including the following switchgears complete all as specified and as directed Incoming (a) MCCB 125A, 4 pole, 25kA, 415V Icu=100%Ics- 04Nos Outgoing (a) MCCB 100A, 4 pole, 25kA, 415V Icu=100%Ics- 02Nos (b) MCB TPN 63 A, 10 KA-02 Nos (c) Contactor 3 pole 32 A-01 No (d) Toggle switch 6 A-01 No (e) Timer (analog)with battery backup-01 No (f) Over Load relay 5-8 A-01 No (g)Phase Indicator lamps (RYB) set of 3 -01 Set

1

-

-

... More
Supply, installation, commissioning and testing CPRI approved LT feeder pillar box, outdoor type of suitable size recommended by CPRI approved manufacturer, cubical floor mounted type (IP-65 degree of protection) made out of 3.15mm thick powder coated CRCA sheet , with aluminium strip bus bar 400A rating duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415V 50Hz AC supply, including cable entry boxes, cable gland, with 50x50x6mm angle iron supports, bottom portion duly grouted in PCC foundation as per manufacturer's instructions totally tested as per IEC 61439-I including the following switchgears complete all as specified and as directed Incoming (a) MCCB 250A, 4 pole, 25kA, 415V Icu=100%Ics- 01Nos (b) LED Indicator lamps (RYB) set of 3 -01 Set Outgoing (a) Through bus bar

1

-

-

... More
Notes for serial item Nos. 67 to 68: (a) The Contractor shall submit drawings from the approved OEM for approval of the GE through the Engineer-in-charge (b) The panels shall include 2Nos. danger notice plates made of 1.6mm thick mild steel sheet, vitreous enamelled white, of size 250x200mm with letter, figures and conventional skull bones in signal red colour duly fixed with nuts, bolts and washers, etc. with voltage and danger indicated both in Hindi and English (c) Excavation, earthwork in any type of soil, construction of PCC foundation for panel shall be deemed included in quoted rate. Foundation specifics shall be as per OEM of panel. The Contractor shall submit foundation desgn drawings to attain approal of he GE (d) Foundation bed shall be in PCC 1:3:6 type C2 using 40mm graded stone aggregates with a depth of 15cm below ground level and 1.5m above ground level with stare and slot openings for I/C and O/G cables

-

-

-

... More
M&L for earthing with galvanised iron earth plate electrode 600x600x6mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below ground level connetced with galvanised strip of size 25x4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (using 20mm graded stone aggregates), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 150mm C/C bothways and suitable handle made of 10mm dia ound bar including all necessary earthwork, excavation, returning filling in any type of soil and removing surplus earth upto a distance not exceeding 50m all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) including testing on completion and making test points on wall as per SSR specifications complete all as specified and as directed

2

-

-

... More
Notes for serial item No. 150 : (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge

-

-

-

... More
M&L for taking down AC units for required servicing, cleaning of cooling coil, air filters/plasma filters, etc. (indoor unit), condenser, compressors, fan motor, etc. (outdoor unit) with vacuum cleaner and cleaning solutions, etc., checking serviceability of electrical / electronic parts viz. circuit relays, wiring kit, thermostat switches, knobs, remote control unit, fan, blower, etc. and ensuring the AC unit in satisfactory working conditions complete all as specified and as directed for the following: Notes:(a) Spares / parts / components replaced will be measured and paid separately under relevant items hereinafter and labour charges for replacement including all allied works shall be deemed to be included in the unit rate quoted (b) Gas charging as required shall be deemed to be included in the quoted rate (c) Cost of taking down, loading / unloading, carting (to & fro) to workshop if required shall be deemed to be included in the quoted rate

-

-

-

... More
Split type AC 1.5/2TR

12

-

-

... More
Window type AC 1.5/2TR

4

-

-

... More
Supply, installing, testing and commissioning of compressors of AC units in any location / position including disconnecting electrical mains, remove the refrigerant and capture it in a storage cylinder, cutting line sets, removing the condenser coil and everything around the compressor, taking out the condenser unit, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally put the rest back together and balance charging of refrigerant gas F-22/R-134A (if required) including disposing of old unserviceable condensor unit complete all as specified and as directed of the following capacities: Notes: (i) Compressor units shall be from manufacturer as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum warrantee of 5years and as given by manufacturers

-

-

-

... More
2Ton

4

-

-

... More
1.5Ton

4

-

-

... More
M&L for charging refrigerant gas F-22/R-134A in split type AC unit of any capacity including required staging / taking down of compressor units, etc. as required, detecting leakages, etc. stopping leakages by welding and testing on commissioning in satisfactory working conditions complete all as specified and as directed

15

-

-

... More
S&F the following spare parts including necessary fittings as per sample and suitable for and in maintenance of air conditioner units of capacity 1.5/2T complete all as specified

-

-

-

... More
Thermostat switch with regulator knob unit and necessary fittings

5

-

-

... More
Starting capacitor of 80/100/120MFD

6

-

-

... More
Selector switch with knob including necessary fittings

4

-

-

... More
Blower motor capacitor 8MFD

5

-

-

... More
Running capacitor 36MFD

4

-

-

... More
Running capacitor 50MFD

2

-

-

... More
Strainer/Drier

3

-

-

... More
Remote control PCB circuit

8

-

-

... More
Overload protector relay

4

-

-

... More
Front grill as per existing pattern including fixing screws and accessories

4

-

-

... More
Air filter

4

-

-

... More
Capillary charging

2

-

-

... More
MS stand as per approved drawing and specifics

4

-

-

... More
M&L for disconnecting from mains and taking down for servicing water coolers including cleaning the cooling coil, air filters, condenser, compressors, fan motor, etc. with vacuum cleaner and cleaning solution, checking serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc. and making the water cooler to satisfactory working conditions complete all as specified and as directed of the following capacities: Notes: (a) Spares / parts / components replaced will be measured and paid separately under relevant items hereinafter and labour charges for replacement including all allied works shall be deemed to be included in the unit rate quoted (b) Gas charging as required shall be deemed to be included in the quoted rate (c) Cost of lifting, loading / unloading, carting (to & fro) to workshop as required shall be deemed to be included in the quoted rate

-

-

-

... More
150 litres

5

-

-

... More
60 to 120 litres

4

-

-

... More
40 to 80 litres

5

-

-

... More
S&F company made new sealed compressor units for water coolers of capacity 60/120litres, including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum warrantee of 5years and as given by manufacturers

4

-

-

... More
S&F company made new sealed compressor units for water coolers of capacity 40/80litres, including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum warrantee of 5years and as given by manufacturers

5

-

-

... More
M&L for charging refrigerant gas F-22/R-134A in water cooler units of any capacity and testing on commissioning in satisfactory working conditions complete all as specified and as directed

6

-

-

... More
S&F in repairs blower motor assembly of water coolers of any make, as per existing including necessary fittings viz. clamps, nuts, bolts, etc. complete all as specified and as directed

4

-

-

... More
S&F in repairs condensing coil assembly of water coolers of any make, including necessary fittings viz. clamps, nuts, bolts, etc. and all required soldering, brazing, etc. complete all as specified and as directed

5

-

-

... More
Supply only the following spare parts as per sample and suitable for and in maintenance of water coolers for capacity 40/60/80/120/150 litres including necessary fittings complete all as specified:

-

-

-

... More
Starting capacitor 60-80Mfd

4

-

-

... More
Running capacitor 25Mfd

5

-

-

... More
Thermostatic switch with regulating knob

4

-

-

... More
Push cock, self closing chromium plated 15mm bore including nut and washer, etc.

4

-

-

... More
PVC drain pipe 1m long including clamps

3

-

-

... More
Float valve of gun metal, 15mm bore with ball

3

-

-

... More
Over load protector relay

4

-

-

... More
Running capacitor 36Mfd

4

-

-

... More
Pencil strainer

2

-

-

... More
Relay box type 1022

3

-

-

... More
M&L for disconnecting from mains, for servicing refrigerators including cleaning the cooling coil, air filters, condenser, compressors, fan motor, etc. with vacuum cleaner and cleaning solution, checking serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches, knobs, leakage of gas, etc. and making the deep freezer / refrigerator to satisfactory working conditions complete all as specified and as directed of the following capacities: Notes: (a) Spares / parts / components replaced will be measured and paid separately under relevant items hereinafter and labour charges for replacement including all allied works shall be deemed to be included in the unit rate quoted (b) Gas charging as required shall be deemed to be included in the quoted rate (c) Cost of lifting, loading / unloading, carting (to & fro) to workshop if required shall be deemed to be included in the quoted rate

-

-

-

... More
310llitres

5

-

-

... More
230/285/286 litres

4

-

-

... More
165/175/185litres

5

-

-

... More
S&F company made new sealed compressor units for refrigerators, including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed for the following capacities: Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum warrantee of 5years and as given by manufacturers

-

-

-

... More
165/175/185/310 litres

5

-

-

... More
M&L for charging refrigerant gas F-22/R-134A in refrigerator units of any capacity and testing on commissioning in satisfactory working conditions complete all as specified and as directed

7

-

-

... More
Supply only the following spare parts as per sample and suitable for and in maintenance of refrigerators including necessary fittings complete all as specified and as directed

-

-

-

... More
Relay open type (over load cum relay)

3

-

-

... More
Overload protector

4

-

-

... More
Cooling coil door with locking spring

3

-

-

... More
Thermostat switch with regulating knob

4

-

-

... More
Fan motor / evaburator

2

-

-

... More
Fan blade

3

-

-

... More
Chiller tray as per existing model

4

-

-

... More
Frost free timer

1

-

-

... More
Frost free cooling coil

2

-

-

... More
Capillary charging

2

-

-

... More
Thermal fuse

5

-

-

... More
Strainer/ drier round type for refrigerator

3

-

-

... More
Relay box type 1/6 Hp

4

-

-

... More
Switch for cabinet bulb

3

-

-

... More
M&L for disconnecting from mains, for servicing refrigerators including cleaning the cooling coil, air filters, condenser, compressors, fan motor, etc. with vacuum cleaner and cleaning solution, checking serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches, knobs, leakage of gas, etc. and making the deep freezer / refrigerator to satisfactory working conditions complete all as specified and as directed of the following capacities: Notes: (a) Spares / parts / components replaced will be measured and paid separately under relevant items hereinafter and labour charges for replacement including all allied works shall be deemed to be included in the unit rate quoted (b) Gas charging as required shall be deemed to be included in the quoted rate (c) Cost of lifting, loading / unloading, carting (to & fro) to workshop if required shall be deemed to be included in the quoted rate

5

-

-

... More
M&L for charging refrigerant gas F-22/R-134A in deep freezer units of any capacity and testing on commissioning in satisfactory working conditions complete all as specified and as directed

4

-

-

... More
M&L for in repair Compressor hermetically sealed suitable for matching with existing size and make of deep freezer including fitting, complete all as specified and as directed

4

-

-

... More
S&F in repairs heater for deforsting purposes, suitable for matching with existing of any capacity and make of deep freezer complete all as specified and as directed

3

-

-

... More
S&F in repairs FF timer , suitable for matching with existing of any capacity and make of deep freezer complete all as specified and as directed

2

-

-

... More
S&F in repairs PCB timer, suitable for matching with existing of any capacity and make of deep freezer complete all as specified and as directed

5

-

-

... More
S&F in repairs capacitor 3.5,5 or 6 mfd,suitable for matching with existing of any capacity and make of deep freezer complete all as specified and as directed

4

-

-

... More
S&F in repairs relay set, PCTR, suitable for matching with existing of any capacity and make of deep freezer complete all as specified and as directed

2

-

-

... More
S&F in repairs fan motor, with fan blade 220-240 volt, 0.10 Amp suitable for matching with existing of any capacity and make of deep freezer complete all as specified and as directed

4

-

-

... More
S&F in repairs door switch,suitable for matching with existing of any capacity and make of deep freezer complete all as specified and as directed

2

-

-

... More
S&F in repairs thermostat,suitable for matching with existing of any capacity and make of deep freezer complete all as specified and as directed

2

-

-

... More
S&F in repairs drier/strainer,suitable for matching with existing of any capacity and make of deep freezer complete all as specified and as directed

5

-

-

... More
M&L for writing of MES No. & Capacity of refrigerators/deep freezer/air conditioner/solar water heaters with black synthetic enamelled paint , writing of figures (Block,Italic or Indian ) not exc. 30 cm in height,complete all as specified and as directed

8

-

-

... More
S&F in repair of Volatge Stabiliser of current rating 15A and voltage rating 90V-300V suitable for existing 1.5/2 Ton airconditioner, complete all as specified and as directed

7

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.