Military Engineer Services Tender
... More
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_694610_1Tender No
84117/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
S&F Contactor with AC3 Rating 65 Amp & AC1 Rating 100 Amp and Providing Connections including Taking down/ out Unserviceable Contactor of any description after disconnecting all Electrical Connections, complete all as specified and as directed.
8
-
-
... More
S&F Electrically Controlled Damper Actuators suitable for Controlling Flow Rate of Water in either Hot or Cold Water Line and Providing Connections including Taking down/ out Unserviceable Damper Actuators of any description after disconnecting all Connections, complete all as specified and as directed.
MAKE : HONEYWELL, Model No. CN72202007
2
-
-
... More
S&F Electronic Timer Working on 240 Volt AC, 50 Hz with Timing Range 3.0 Second to 120 Second and Providing Connections including Taking down/ out Unserviceable Timer of any description after disconnecting all Electrical Connections, complete all as specified and as directed.
12
-
-
... More
S&F Expansion Valve 30 TR Capacity and Providing Connections including Taking down/ out Unserviceable Expansion Valve of any description after disconnecting Connections, complete all as specified and as directed.
2
-
-
... More
S&F Liquid Line Filter Drier for use with R22 Gas suitable for 80 TR Chiller Unit and Providing Connections including Taking down/ out Unserviceable Liquid Line Filter Drier of any description after disconnecting Connections, complete all as specified and as directed.
2
-
-
... More
S&F Single Phase Preventer Working on 3 Phase 440 Volt Supply and Providing Connections including Taking down/ out Unserviceable Preventer of any description after disconnecting Connections, complete all as specified and as directed.
12
-
-
... More
S&F Thermal Overload Relay suitable for fixing with Contactor with Relay Range between 6 Amp to 10 Amp and Providing Connections including Taking down/ out Unserviceable Relay of any description after disconnecting Connections, complete all as specified and as directed.
12
-
-
... More
S&F Universal Controller suitable for Controlling the Rotational Movement of Damper Actuators and Providing Connections including Taking down/ out Unserviceable Universal Controller of any description after disconnecting Connections, complete all as specified and as directed.
MAKE : SIEMENS, Model No. RLU222 or as Approved by GE
2
-
-
... More
M&L Repairing Automatic Power Factor Correction (APFC) Panel 125 KVAR Capacity by Replacing under-mentioned Unserviceable/ Defective Parts, Making Serviceable Complete in all respect and Providing Connections including Taking down/ out Unserviceable/ Defective Parts of any description from APFC Panel after disconnecting all Connections, complete all as specified and as directed :-
(a) Capacitor Bank 12.5 KVAR - 01 No.
(b) Capacitor Bank 25 KVAR - 04 No.
(c) Contactor MNX 45 - 03 No.
(d) Fuse 125 Amp, 100 kA - 04 No.
(e) MCCB 250 Amp, 4 Pole, 25 kA Capacity - 01 No.
(f) HF Fuse 2 Amp, 415 Volt - 04 No.
(g) HF Fuse 4 Amp, 415 Volt - 02 No.
(h) HF Fuse 6 Amp, 415 Volt - 02 No. (j) HF Fuse 16 Amp, 415 Volt - 01 No.
(k) HF Fuse 63 Amp, 415 Volt - 05 No.
(l) Power Factor Control Relay - 01 No.
1
-
-
... More
M&L Repairing Automatic Power Factor Correction (APFC) Panel 150 KVAR Capacity by Replacing under-mentioned Unserviceable/ Defective Parts, Making Serviceable Complete in all respect and Providing Connections including Taking down/ out Unserviceable/ Defective Parts of any description from APFC Panel after disconnecting all Connections, complete all as specified and as directed :-
(a) Capacitor Bank 12.5 KVAR - 02 No.
(b) Capacitor Bank 25 KVAR - 03 No.
(c) Contactor MNX 45 - 04 No.
(d) Fuse 125 Amp, 100 kA - 05 No.
(e) MCCB 250 Amp, 4 Pole, 25 kA Capacity - 01 No.
(f) HF Fuse 2 Amp, 415 Volt - 05 No.
(g) HF Fuse 4 Amp, 415 Volt - 03 No.
(h) HF Fuse 6 Amp, 415 Volt - 04 No. (j) HF Fuse 16 Amp, 415 Volt - 01 No.
(k) HF Fuse 63 Amp, 415 Volt - 06 No.
(l) Power Factor Control Relay - 01 No.
1
-
-
... More
Disconnecting Connections and Taking down/ out Unserviceable or Serviceable UG Cable, Cross Sectional Area upto 25 Sqmm, 4.0 Core after disconnections, Cables laid in Trenches and/ or Fixing with Walls/ Poles, complete all as specified and as directed.
NOTE : Earth Work will be Measured and Paid separately under relevant Items.
225
-
-
... More
Disconnecting Connections and Taking down/ out Unserviceable or Serviceable UG Cable, Cross Sectional Area exc. 185 Sqmm and not exc. 300 Sqmm, 3½ Core after disconnections, Cables laid in Trenches and/ or Fixing with Walls/ Poles, complete all as specified and as directed.
NOTE : Earth Work will be Measured and Paid separately under relevant Items.
200
-
-
... More
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/ up and Laying of Electric Cables, etc., Forming Surfaces to required Foundation and getting out as in Soft/Loose Soil, complete all as specified and as directed
48.6
-
-
... More
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in layers not exc. 25 Cm, Providing Heaps along the Route of the Water Mains, Cable Lines, etc. with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed.
26.6
-
-
... More
Removing Excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point in Soil, complete all as specified and as directed.
22
-
-
... More
M&L Horizontal Boring below/ under Hardstanding, Pavements, Roads, etc. not exc. 10.00 Metre in a Single Length for Crossing/ Passing Pipe upto 80mm bore (dia) in Soft/ Loose Soils, complete all as specified and as directed.
NOTE : Protection Pipe will be Measured & Paid separately under appropriate Item.
12
-
-
... More
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross Sectional Area 25 Sqmm, 4.0 Core including Cable Glands, Lugs, etc. and Providing Electrical Connection, Laid in Trenches/ Ducts or Passing through Pipe or Fixing to Poles, Walls, etc. with suitable Size Mild Steel Saddle, Clips, etc., complete all as specified and as directed.
NOTE : Necessary Earth Works, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under appropriate Items.
225
-
-
... More
M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross Sectional Area 300 Sqmm, 3½ Core including Cable Glands, Lugs, etc. and Providing Electrical Connection, Laid in Trenches/ Ducts or Passing through Pipe or Fixing to Poles, Walls, etc. with suitable Size Mild Steel Saddle, Clips, etc., complete all as specified and as directed.
NOTE : Necessary Earth Works, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under appropriate Items.
200
-
-
... More
M&L Sand Cushioning (Dry) in Trenches/Ducts for protection of UG Cables (below, above & around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in thick Before Laying the Cable and 15 Cm in thick After Laying the Cable) and Consolidated (Punned) upto 180mm thick, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
14.6
-
-
... More
Supply & laying Sub-class ‘B’ Bricks of Size 230x115x75 mm, Kiln burnt, for Covering to UG Cable as Mechanical Protection, laid Flat, Transversally Width Equal to the Length of the Cable, complete all as specified and as directed.
14.4
-
-
... More
M&L Galvanised Steel Tubing Pipe 80mm bore (dia), Light grade with Bend, laid in Trenches or under Roads/ Flooring, etc., complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured and Paid separately under appropriate Items.
12
-
-
... More
M&L Earthing Complete with Galvanised Earth Plate Electrode 600x600x6.0mm thick buried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, Connected with and including Galvanised Earth Strip of Size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) ‘Light’ grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregates) and Pre-cast RCC 1:2:4 (20mm graded stone aggregates) Cover Slab of Size 450x450x50mm, Reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) ‘Medium’ grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
6
-
-
... More
DEDUCTION AGAINST SCHEDULE OF CREDIT
Bidder(s) shall/ will Quote the EQUAL AMOUNT as per SCHEDULE OF CREDIT catered at SERIAL PAGE No. 18 in the Tender Documents under Column 5 i.e. 'UNIT RATE' (M) against Row No. 38 .
1
-
-42000
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements