Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Building Construction
Eprocure
Opening Date18 Mar 2024
Closing Date15 Apr 2024
Tender Amount₹ 75,50,000
Costs
EMD
₹ 1,38,500Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_646918_1Bid Award Id
ViewTender No
8760/SHL/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
S&F Pre-painted galvalume aluminum zinc coating, GI based Plain steel sheet, 0.50 mm thick, of any colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc. complete, all as specified and as directed by Engineer-in- charge.
130
-
-
M&L for hard core of broken stones or boulders, of gauge n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surfaces complete, all as specified and as directed by Engineer-in- charge.
5
-
-
M&L for 100 mm thick PCC 1:2:4 type B2, using 40 mm graded stone aggregates, as in flooring, finished even and fair without using extra cement, including necessary formwork complete, all as specified and as directed by Engineer-in- charge.
500
-
-
M&L for 150mm thick PCC 1:2:4 type B2, using 40 mm graded stone aggregates, as in flooring finished even and fair without using extra cement including necessary formwork complete, all as specified and as directed by Engineer-in- charge.
50
-
-
M&L Forming 12mm thick Expansion joints and 100mm Thickness of concrete slab filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade `A' complete, all as specified and as directed by Engineer-in- charge.
10
-
-
M&L for Forming Construction joint 30mm deep x 10mm wide, filled with sealing compound , Grade 'A' complete, all as specified and as directed by Engineer-in- charge.
10
-
-
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work and pre-cast concrete articles complete all as specified and as directed by Engineer-in- charge.
35
-
-
M&L for Brick work with sub-class 'B' old sized bricks, straight or curved on plan, exc 6m mean radius and built in CM 1:6 etc complete all as specified and as directed by Engineer-in- charge.
35
-
-
Taking down chowkats or frames not exceeding 1.5 Sqm each (with shutters & with out taking off shutters from the frame) and removing away from site, complete all as specified and as directed by Engineer-in- charge.
50
-
-
Taking down chowkats or frames exc 1.5 Sqm and not exceeding 4 Sqm each (with shutters without taking off shutters from the frame) and removing away from site, complete all as specified and as directed by Engineer-in- charge.
3
-
-
S&F pressed steel frames for doors, of size 105 mm x 60mm, with one or more rebates, including necessary fixing lugs, hinges, lock strike plate, with and including PCC 1:3:6 type C0 filled in hollow frame etc., complete all as specified and as directed by Engineer-in- charge.
18
-
-
S&F flush shutters, 30mm thick , solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed by Engineer-in- charge.
12
-
-
S&F aluminium anodised barrel tower bolts of extruded sections 150 mm size complete all as specified and as directed by Engineer-in- charge.
6
-
-
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and as directed by Engineer-in- charge.
3
-
-
S&F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and as directed by Engineer-in- charge.
15
-
-
M&L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and as directed by Engineer-in- charge.
25
-
-
S&F in repairs, suspended false ceiling, using E-grid 2430, 180 GSM (exposed ceiling suspension system) of grid size 600 mm x 600 mm with main runner of size 38 mm x 24 mm and wall angle 24 mm x 24 mm with and including and using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) in a grid of GI system, duly suspended with and including 3mm dia GI wire hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c with the last hanger at the end of each main runner should not be placed at more than 450 mm from the adjacent wall, Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid including dismantling old defective suspended false ceiling, complete all as specified and as directed by Engineer-in- charge.
20
-
-
S&F steel windows with side hung shutters glazed shutter including projecting type hinges with steel handle and steel peg stay with glazing bars and 12 mm square bar or ground bar of approved design welded to steel window frame dovetailed or welded complete all as specified and as directed by Engineer-in- charge.
40
-
-
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in- charge.
3
-
-
M&L for providing precast cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) as in cover slab, set in cement mortar 1:6, including necessary formwork complete all as specified and as directed by Engineer-in- charge. NOTE:- Reinforcement shall be measured and paid separately.
3
-
-
M&L for TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips working end and binding with and including MS wire (annealed) not less than 0.9 mm dia as in reinforcement complete all as specified and as directed by Engineer-in- charge.
150
-
-
Demolition of cement Concrete (unreinfored) of any description and in any position, not otherwise specifically provided for complete all as specified and as directed by Engineer-in- charge.
19.25
-
-
M&L for cement concrete type B-2, 1:2:4, using 40mm graded stone aggregates, as in surface channels and drain with and including neceaary formwork, complete all as specified and as directed by Engineer-in- charge.
8
-
-
Dismantling of stone slabs and tiles of any description or thickness, in floors, aprons, platform, shelves etc. laid, bedded and pointed in any mortar, complete all as specified and as directed by Engineer-in- charge.
5
-
-
M&L for Machine pressed precast concrete interlocking paver block, with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 100 mm thickness, M-50 Grade, laid over and including 30 mm thick sand cushioning complete all as specified and as directed by Engineer-in- charge.
50
-
-
Dismantling wrought iron or mild steel work of any description and in any position not otherwise provided for complete all as specified and as directed by Engineer-in- charge.
28
-
-
S&F Rolled mild steel work in tubular trusses, including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 St- 240 complete all as specified and as directed by Engineer-in- charge.
1000
-
-
S&F Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars for windows; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed by Engineer-in- charge.
1400
-
-
S&F Rolled mild steel Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections for use in sliding Iron doors using Rolled mild steel of grade Fe 410 -W (Gde E- 250) quality A, complete all as specified and as directed by Engineer-in- charge.
400
-
-
S&F Fibre glass reinforced translucent corrugated sheeting 2mm thick with two corrugations side lap fixed with coach screw and washer in roof, wall etc. complete all as specified and as directed by Engineer-in- charge.
25
-
-
S&F 1.00 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed), complete all as specified and as directed by Engineer-in- charge.
100
-
-
M&L for Taking down cement plaster, any description, on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and as directed by Engineer-in- charge.
653
-
-
M&L for 15 mm thick rendering in CM 1:6 on brick/ concrete surfaces and finishing the surfaces even and smooth without using extra cement, complete all as specified and as directed by Engineer-in- charge.
453
-
-
M&L for rendering 15 mm thick in CM 1:4 on brick / concrete surfaces and finishing the surfaces even and smooth without using extra cement, complete all as specified and as directed by Engineer-in- charge.
500
-
-
M&L for preparation of newly plastered surfaces of walls and applying one coat of alkali resistant primer over a coat of birla white cement putty, sanding the surfaces till smooth finish is obtained and finally applying two coats of oil emulsion distemper, complete all as specified and as directed by Engineer-in- charge.
453
-
-
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer, complete, all as specified and as directed by Engineer-in- charge.
500
-
-
Hacking out old broken glass (any thickness, quality or description) from wooden / steel frame or stone concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed by Engineer-in- charge.
50
-
-
S&F Rough cast wired glass, 6.4 mm thick, in square n exc 0.5 sq. m in each pane and glazing with oil putty complete all as specified and as directed by Engineer-in- charge.
18
-
-
S&F frosted quality sheet glass, in squares not exc. 0.50 sqm in each pane, 4.8 mm thick, and glazing with oil putty complete all as specified and as directed by Engineer-in- charge.
32
-
-
M&L for preparation of new steel surfaces exc 10 cm width / girth and applying two coats of synthethic enamel paint over a coat of zinc oxide chrome primer, complete all as specified and as directed by Engineer-in- charge.
100
-
-
M&L for preparation of old painted steel surfaces exc 10 cm width / girth and applying one coat of synthethic enamel paint complete all as specified and as directed by Engineer-in- charge.
150
-
-
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer-in- charge.
2000
-
-
M&L 75mm thick PCC, type C-1, 1:3:6 (using 20 mm graded stone aggregates), as in plinth protection, finished even and smooth without using extra cement with and including and providing 10 mm wide groove at every 3 mtr interval and filled with bituminious filler complete all as specified and as directed by Engineer-in- charge.
150
-
-
S&F in repair PVC (SWR) pipes, 150mm dia, single socketed, in any length with rubber ring joints, laid in trenches or in floors including taking down old defective PVC pipe and removing away from site, complete all as specified and as directed by Engineer-in- charge.
114
-
-
S&F in repairs PVC (SWR) bends, 150mm dia, with rubber ring joints and fixed including taking down old defective PVC bends, complete all as specified and as directed by Engineer-in- charge.
20
-
-
E&M-PORTION Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed by Engineer-in- charge.
165
-
-
M&L in repairs for Point wiring using 1.5 sq mm, two single core, PVC insulated and PVC sheathed FRLS cable, 1100 volts grade, conforming to IS -694, IS marked, with multistranded copper conductors and one earth continuity wire with 1.5 Sqmm cable (including connecting to earth dolly) laid / fixed / drawn through and including PVC rigid conduit and also providing and including sunken type pressed steel terminal box with 3 mm thick plastic laminated sheet top cover, suitable for One light point / fan point controlled by one 5 Amp switch complete all as specified and as directed by Engineer-in- charge.
160
-
-
All as per item No 49 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board complete all as specified and as directed by Engineer-in- charge.
5
-
-
All as per item serial No 49 here-in-before but for One 3 pin socket outlet, 6 amps on the same board with other switches, complete all as specified and as directed by Engineer-in- charge.
10
-
-
All as per item serial No 49 here-in-before but Point wiring using 2.5 Sqmm, two single core multistranded copper conductor cable for 6 pin 15 Amp socket outlet on independent board and one 2.5 Sqmm, single core multistranded copper conductor cable as earth continuity wire complete all as specified and as directed by Engineer-in- charge.
10
-
-
S&F in repairs switch flush type 5 Amp 240 Volts single pole, one way (ISI marked), complete all as specified and as directed by Engineer-in- charge.
170
-
-
S&F in repairs Socket outlet 2 in 1, 3 Pin 5 Amp flush type 240 volts, complete all as specified and as directed by Engineer-in- charge.
10
-
-
S&F in repairs switch socket combination, 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed by Engineer-in- charge.
5
-
-
S&F in repairs switch socket combination, multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed by Engineer-in- charge.
10
-
-
S&F in repairs ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and as directed by Engineer-in- charge.
165
-
-
Supply and fixing in repairs LED lights fitting 1x 20W, 220V, AC decorative batten with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer-in- charge.
150
-
-
Supply and fixing saucer next generation highbay light of 100 watt LED with energy saving and with PDC housing suitable for ceiling (surface / suspended) mounting complete all as specified and as directed by Engineer-in- charge.
10
-
-
S&F in repairs factory made, sheet steel distribution boards, double door, protection class IP-42, SPN 8 Ways suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified and as directed by Engineer-in- charge.
8
-
-
S&F in repairs MCB SP 5- 32Amps, 240 V,50 HZ,B series breaking capacity 10KA all as specified and directed. Make-Legrand, cat part no-4085 87 to 95 or equivalent, complete all as specified and as directed by Engineer-in- charge.
48
-
-
S&F in repairs MCB SP 40 Amps, 240 V,50 HZ,B series breaking capacity 10KA all as specified and directed. Make-Legrand, cat part no-4085 87 to 95 or equivalent, complete all as specified and as directed by Engineer-in- charge.
24
-
-
S&F in repair MCBs, SPN 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA ,C-series marked fixing in DBs (DBs catered separately in this Schedule) complete all as specified and as directed by Engineer-in- charge.
8
-
-
S&F in repair factory made, sheet steel distribution boards, TPN, 4 Way, double door,with provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, complete all as specified and as directed by Engineer-in- charge.
2
-
-
S&F in repair MCB Tripple pole & neutral 40 to 100 Amps in accordance with IS/IEC 60898-1, 415 V, 50 Hz,10 kA, C-series rupturing capacity complete all as specified and as directed by Engineer-in- charge.
2
-
-
M&L in repairs for Sub main wiring with 2 runs of 4.0 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and as directed by Engineer-in- charge. Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one RUN / unit.
300
-
-
M&L in repairs for wiring with 2 runs of 1.5 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 1.5 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old wiring and type of conduit complete all as specified and as directed by Engineer-in- charge. Note: 2 run of 1.5 Sqmm cable and 1 run of 1.5 Sqmm cable along with conduit altogether shall be measured as one RUN / unit.
135
-
-
S&F in repair LED 35 W building secruity light made up of pressure die cast housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07 and suitable for dia upto 43 mm complete all as specified and as directed by Engineer-in- charge.
15
-
-
M&L for GI bracket made out of 40 mm bore medium grade GI Pipe with two sets of clamps, with nuts and bolts, bend to shape all as directed, length of GI Pipe shall not be less than 2.0 metre for fixing of light fittings including taking out old bracket complete all as specified and as directed by Engineer-in- charge.
15
-
-
Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including galvanised earth lead wire 4 mm upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 20 mm dia GI pipe connected to main control board and GI pipe medium grade 40 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009
2
-
-
Supply, laying and testing XLPE cable, Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core, complete all as specified and as directed by Engineer-in- charge.
55
-
-
Excavating in trenches n.exc 1.5mtr wide and n.exc. 1.5m in depth for foundation / laying cable and getting out in soft/loose soil, complete all as specified and as directed by Engineer-in- charge.
8.1
-
-
Supply and spreading fine dry river sand for cushioning to UG cable, laying 8 cm thick sand before laying cable and 15 cm over cable punned down to 18 cm, including spreading levelling and hand punning etc, complete all as specified and as directed by Engineer-in- charge. NOTE:- PUNNED thickness of sand to be measured and paid.
3.24
-
-
M&L for providing sub class ‘B’ bricks, old size, for cable protection laid flat in trenches over the cable perpendicular to the direction of cable, for cable protection, complete all as specified and as directed by Engineer-in- charge.
0.34
-
-
Returning, filling in, soft/loose soil, including spreading, levelling, watering and well ramming in layers n.exc. 25cm, complete all as specified and as directed by Engineer-in- charge.
3.76
-
-
Removing of excavated soil to a distance not exc 50 m & depositing where directed at a level n.exc 1.5m above starting point, complete all as specified and as directed by Engineer-in- charge.
4.33
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements