Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date31 May 2024
Closing Date6 Jul 2024
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for sand cushioning for protection of lT under ground cable with screen wash sand and punning to proper reqd cover complete all as specified and directed

5

-

-

... More
M & L brick protection with old size sub class ‘B’ brick for PVC under ground cable protection in trench with width equal to length of brick laid dry and flat joining each other with gap between adjacent brick not exceeding 10mm over LT under ground cable complete all as specified and directed

530

-

-

... More
M&L for cement concrete in foundations, filling and mass concreteType C2 1:3:6, 40mm graded aggregate complete all as specified and directed

9

-

-

... More
M&L for PCC as in foundation or any other works type B1 (1:2:4) (20mm graded aggregate) complete all as specified and directed. Note: Any form work required for PCC works are deemed to be incl.

5

-

-

... More
M&L rendering 10mm thick in CM 1:6 on fair faces of brick works or concrete surfaces complete all as specified and directed

50

-

-

... More
M&L for taking out of old/ unserviceable cable of any sizes or types for replacement with new one complete all as specified & directed.

2520

-

-

... More
M&L for re-laying heavy duty LT under ground cable of any sizes and types in pipe / trench / cable duct / fixed on wall by proper size shaped GI clamps with nut bolts etc. and making good the disturbed surfaces by cement mortar/ paint to match with the existing surface complete all as specified & directed.

350

-

-

... More
M&L for LT Cable fault detection and its rectification by using Cable fault locator machine of span length maximum 2km of cable size 95 to 400 sqmm complete all as specified and directed Note: Suitable excavation and jointing kit will be measured and paid seperately.

4

-

-

... More
S&L in repair of UG cable XLPE insulated,armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross section area including taking down of size 185 sq mm 3.5 core complete all as specified and directed.

100

-

-

... More
All as per Serial item No.12.00 here-in-before but size 150 sqmm 3.5 core complete all as specified and directed.

100

-

-

... More
All as per Serial item No.12.00 here-in-before but size 95 sqmm 3.5 core complete all as specified and directed.

120

-

-

... More
All as per Serial item No.12.00 but size 70 sqmm 3.5 core complete all as specified and directed

250

-

-

... More
All as per Serial item No.12.00 but size 50 sqmm 3.5 core complete all as specified and directed

300

-

-

... More
All as per Serial item No.12.00 but size 25 sqmm 3.5 core complete all as specified and directed

600

-

-

... More
All as per Serial item No.12.00 but size 16 sqmm 4 core complete all as specified and directed

500

-

-

... More
All as per Serial item No.12.00 but size 10 sqmm 2 core complete all as specified and directed

200

-

-

... More
M&L for boring under roads or any other specified location by reqd T&P without disturbing the top surface of the road for insertion of GI Pipe of 50 to 100 mm dia etc complete all as specified and directed.

60

-

-

... More
M&L for HDPE Double wall corrugated pipe of size 110/95 mm as per IS: 16098 Part-II-2013 and ISO 21138 & BSEN 13476-1TO 3 laid in trenches/wall for protection cables complete all as specified and directed.

652

-

-

... More
S&F in repairs for tubes 50 mm bore light grade galvanized with all fittings laid in trenches/ wall/ pole through MS flat (25X3 mm), nut, bolt & washers [ where ever reqd ] of proper sizes for protection cables complete all as specified and directed.

24

-

-

... More
All as per Serial item No. 22.00 but bore size 40 mm complete all as specified and directed

12

-

-

... More
M&L for replacement of cable duct cover or any other works made up of chequered plate of thickness 8mm with lifting handle (whereever reqd) including fabrication works such as cutting, welding & bent to shape and painting with two coats of black japan paint over a coat of red oxide primer on steel surfaces of any description over 10cm in width or girth including preparation of new untreated surfaces complete all as specified and directed.

250

-

-

... More
M&L angle iron / flat bar of required sizes with locking arrangements including fabrication works such as such as cutting, welding & bent to shape and painting with two coats of black japan paint over a coat of red oxide primer on steel surfaces of any description over 10cm in width or girth including preparation of new untreated surfaces complete all as specified and directed.

200

-

-

... More
M&L for fixing the aluminium terminal (Cable Lugs) in cable end (through corrosion inhibiting compound) of cable size 185 sqmm complete all as specified and directed. Note: Corrosion inhibiting compound which will be used during crimping of terminal shall be measured and paid separately.

20

-

-

... More
All as per Serial item No-26.00 but for cable size 150 sqmm complete all as specified and directed

20

-

-

... More
All as per Serial item No-26.00 but for cable size 95 sqmm complete all as specified and directed

28

-

-

... More
All as per Serial item No-26.00 but for cable size 70 sqmm complete all as specified and directed

28

-

-

... More
All as per Serial item No-26.00 but for cable size 50 sqmm complete all as specified and directed

60

-

-

... More
All as per Serial item No-26.00 but for cable size 35 sqmm complete all as specified and directed

72

-

-

... More
All as per Serial item No-26.00 but for cable size 25 sqmm complete all as specified and directed

72

-

-

... More
All as per Serial item No-26.00 but for cable size 16 sqmm complete all as specified and directed

60

-

-

... More
All as per Serial item No-26.00 but for cable size 10 sqmm complete all as specified and directed

25

-

-

... More
M&L for triming the tree branches falling / touching the HT/LT overhead line in various area of AF Station Borjhar with skilled labours, ladders and cutting tools and disposing the branches to a distance not exceeding 50 mtr length complete all as specified and directed.

40

-

-

... More
M&L for replacement of damage/ corroded hinges with new hinges throgh necessary gas / arc welding works complete on the outdoor feeder pillar box/ LT panel/ or any other works complete all as specified and directed.

32

-

-

... More
M &L for replacement of corroded sheet metal doors of outdoor/ inddor feeder pillar box or LT panel with new CRCA sheet of 2 or 3mm thick incl painting the same with two coats of enamel paint of existing shade over a coat of red oxide primer complete incl treatment of new surfaces complete all as specified and directed.

200

-

-

... More
M&L for writing letter, figures, index arrows etc not exceeding 30 cm in height on LT Panel or any other specified location complete all as specified and directed.

100

-

-

... More
M&L for painting of LT Feeder Pillar Box/ Panel Board or any other plant or equipments by two coats of enamel paint of existing shade after treating old painted surfaces complete al as specified and directed.

150

-

-

... More
M&L for cable jointing kit for 1.1KV grade for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 4 core PVC/ XLPE armoured aluminium conductor cable of size 25 - 50 sqmm complete all as specified and directed.

8

-

-

... More
All as per Serial item No-40.00 but size 70-150 sqmm complete all as specified and directed

7

-

-

... More
All as per Serial item No-40.00 but size 185-300 sqmm complete all as specified and directed

2

-

-

... More
M&L for cable jointing kit for 1.1KV grade for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core PVC/ XLPE armoured aluminium conductor cable of size 70-150 sqmm complete all as specified and directed.

3

-

-

... More
All as per Serial item No-43.00 but size 185-240 sqmm complete all as specified and directed

2

-

-

... More
S&F On-Load Manual Change Over Switch (in sheet steel enclosure) 63 Amps 415 Volts, 4 pole after disconnecting all electrical connection including taking down old unserviceable one complete all as specified and directed.

1

-

-

... More
All as per Serial item No-45.00 but capacity 100 Amp complete all as specified and directed

2

-

-

... More
All as per Serial item No-45.00 but capacity 160 Amp complete all as specified and directed

1

-

-

... More
S&F moulded case circuit breaker 80 - 100 Amps 415 Volts (with thermal magnetic release), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In after disconnecting all electrical connection incl. taking down old unserviceable one complete all as specified and directed.

4

-

-

... More
S&F moulded case circuit breaker 125 - 160 Amps 415 Volts (with thermal magnetic release), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In after disconnecting all electrical connection incl. taking down old unsv one complete all as specified and directed.

4

-

-

... More
S&F moulded case circuit breaker 200 - 250 Amps 415 Volts (with thermal magnetic release), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In after disconnecting all electrical connection incl. taking down old unsv one complete all as specified and directed.

2

-

-

... More
M&L steel tubular sewaged pole 9 mtr long complete with MS bas plate,finial taper plug nut bolts, screws as specified type 410SP-31 as per relevant IS specification including two coats of aluminium paint over a coat of red oxide primer including taking down old unserviceable and removing from site complete all as specified and directed (earth work/excavation PCC shall be measured and paid separately under relevant item of schedule).

12

-

-

... More
M&L for fixing the cable junction boxes of size 155 x 210 x 92 mm, with PVC connector 4 way heavy duty for 10 - 16 sq mm, 4.0 /3.5 C, 1100V cable, IP 66/65, weather proof, outdoor installation type with threaded cable glands & pole mounting brackets etc complete all as specified & directed. Make : Hensel / OBO

25

-

-

... More
M &L 2.5 Sqmm, 3 Core Black PVC Insulated Single solid Aluminium conductor round service cable 1100V for connection from loop / junction box to street light / security light complete all as specified and directed.

120

-

-

... More
M&L for tubes 15 mm bore light grade galvanized with all fittings laid in trenches/ wall/ pole through MS flat (25X3 mm), nut, bolt & washers [ where ever reqd ] of proper sizes for protection cables complete all as specified and directed. Make- Nezone/ Bansal/ Jindal

60

-

-

... More
M&L for Earthing complete with copper earth plate electrode of size 600x600x3.15 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to 20×3mm copper strip as earth lead by means of nuts, bolts, check nuts, washers of galvanized iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete all as specified and directed. (copper strip upto 7.5m including testing consider in this item) directed.

13

-

-

... More
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed

10

-

-

... More
M&L for Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed

70

-

-

... More
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the Galvanised iron earth wire 4.0mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI medium grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agregates with 40mm thick cover of RCC (1:2:4) reinforeed with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 40x40x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering, perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filled 150 mm thick all around the earth plate test point made out of 40x8mm FI galvanised with fixing arrangement, funnel wire mesh and earth work in any type of soil returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and directed

8

-

-

... More
Taking down old unsv/ corroded LT feeder pillar box/ Busbar Chamber/ DB's of any sizes or types (after disconnection of all electrical connections) complete for replacement with new one complete all as specified and directed

3

-

-

... More
Supply, install, testing, commissioning LT cubicle type distribution panel of suitable size, IP-65 type (manufactured from CPRI type tested manufacturer i.e. Indo Asian/BCH/L&T/Havells) Outdoor type made out of 3.15 mm thick CRCA sheet supported on structural frame, angle or channel, factory made, fixed on the ground by galvanised nut & bolts, PCC works (1:2:4 Type B-1). The LT cubicle type distribution panel should have enamelled danger notice plate of 1.6 mm thick, duly painted with powder coated paint of shade RAL 7032 (internally & externally) complete all as specified and directed by Engr-in-Charge. The LT distribution panel must have stainless steel hinges, with special type of heavy duty stainless steel front & back door opening, locking arrangements. The Panel should have provision/accommodation of the following electrical items :- INDICATING DEVICES:- (a) Three Phase LED Ammeter, Class - 1 with CT (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No (b) Three Phase LED Voltmeter, Class - 1 (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No (c) LED type panel indicator lamp Make- L&T/Schneider/Siemens = 03 Nos (d) LCD multifunction meter, Make-ABB/Siemens/Legrand/Schneider/L&T-01 No. BUS BAR : (e) Aluminium bus bar 4 strips (covered with PVC insulated sleeves as per colour code) 600 Amps capacity, including connection etc complete =01 Set INCOMING : (f) Moulded case circuit breaker 320-400 Amps 415 Volts (Vertically Placed), 4 pole 36 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 01 No OUTGOING : (g) Moulded case circuit breaker 250-320 Amps 415 Volts (Vertically Placed), 4 pole 36 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 01 No (h) Moulded case circuit breaker 100-125 Amps 415 Volts (Vertically Placed), 4 pole 36 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 04 No (j) Miniature circuit breaker 63 Amps 230 Volts (Vertically Placed), 2 pole 10 KA breaking capacity,C Curve Make - Siemens/ ABB/ Legrand/L&T = 01 No Note : i) The connection between the MCCB and bus bar should be done by aluminium bar of suitable rating ii) All cables in the feeder pillar box should be properly glanded and thimbled.

1

-

-

... More
Supply, install, testing, commissioning LT cubicle type distribution panel of suitable size, IP-65 type (manufactured from CPRI type tested manufacturer i.e. Indo Asian/BCH/L&T/Havells), Outdoor type made out of 3.15 mm thick CRCA sheet supported on structural frame, angle or channel, factory made, fixed on the ground by galvanised nut & bolts, PCC works (1:2:4 Type B-1) . The LT cubicle type distribution panel should have enamelled danger notice plate of 1.6 mm thick, duly painted with powder coated paint of shade RAL 7032 (internally & externally) complete all as specified and directed by Engr-in-Charge. The LT distribution panel must have stainless steel hinges, with special type of heavy duty stainless steel front & back door opening, locking arrangements. The Panel should have provision/accommodation of the following electrical items :- INDICATING DEVICES:- (a) Three Phase LED Ammeter, Class - 1 with CT (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No (b) Three Phase LED Voltmeter, Class - 1 (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No (c) LED type panel indicator lamp Make- L&T/Schneider/Siemens = 03 Nos (d) LCD multifunction meter, Make-ABB/Siemens/Legrand/Schneider/L&T-01 No. BUS BAR:- (e) Aluminium bus bar 4 strips (covered with PVC insulated sleeves as per colour code) 600 Amps capacity, including connection etc complete =01 Set INCOMING : (f)Moulded case circuit breaker 250-320 Amps 415 Volts (Vertically Placed), 4 pole 36 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 01 No OUTGOING : (g) Moulded case circuit breaker 100-125 Amps 415 Volts (Vertically Placed), 4 pole 36 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 02 No (h) Moulded case circuit breaker 67-100 Amps 415 Volts (Vertically Placed), 4 pole 36 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - Siemens/ ABB/ Legrand/L&T = 02 No (j) Miniature circuit breaker 63 Amps 230 Volts (Vertically Placed), 2 pole 10 KA breaking capacity,C Curve Make - Siemens/ ABB/ Legrand/L&T = 01 No Note : i) The connection between the MCCB and bus bar should be done by aluminium bar of suitable rating ii) All cables in the feeder pillar box should be properly glanded and thimbled.

2

-

-

... More
S&F, including fabrication installation of glow sign board made out of ACP sheet of size 4'x3' fitted with the help of supporting clamps/nuts& blots fitted to stainless steel tubing 50 mm dia light grade, all around the ACP Sheet. Name of the installation/Location to be written on both side of the ACP Sheet with stenciles of good quality. The height of the board will be 4' from ground level to bottom of ACP Sheet and 1.5' for fixing below ground level (so the total height is 3'+4'+1.5'=8.5') with and inclusive necessary excavation/PCC all as directed by Engr-in-Charge.(Sample board is available with AGE E/M Office). Note : Approval of each sign board shall be taken by the contractor before fabrication.

6

-

-

... More
M&L for Writing of MES/SM No on installed equipment/Machinery with the help of enamel paint of light grey background with letter on white colour. Approx size of leter is 40 mm complete all as specified and directed

20

-

-

... More
M&L for fabrication of ACP Sheet 3mm thick of size 1.5'x 2' for writing with stencils such as history of machines, manufacturers name,Srl No, Date of installation, SM No/MES No/Machine No complete all as specified and directed Note : For each board, specimen shall be provided by MES Executive duly approved by Engr-in-Charge.

25

-

-

... More
Supply and fix in repairs and testing commissioning for indication lamps with showing red, yellow and green in colour of 22.5mm dia to monitor on panel board suitable for 240V AC supply as existing at site complete all as specified and directed

8

-

-

... More
Supply and fix in repairs and testing commissioning for digital electronic ammeter of cap as existing range with in built selector switch suitable for 415V panel flush pattern square type with adopter or as existing including wiring complete all as specified and directed.

2

-

-

... More
Supply and fix in repairs and testing commissioning for digital electronic voltmeter of cap as existing range with in built selector switch suitable for 415V panel flush pattern square type with adopter or as per existing including wiring complete all as specified and directed.

4

-

-

... More
S & F energy saving LED spike light of IP-66 using COB LED of capacity 8/9 W complete all as specified and directed.

19

-

-

... More
M&L for HDPE Double wall corrugated pipe of size 63/50 mm as per IS: 16098 Part-II-2013 and ISO 21138 & BSEN 13476-1TO 3 laid in trenches/ wall for protection cables complete all as specified and directed.

980

-

-

... More
S&F Double wall corrugated pipe coupler for pipe size 63/50 mm complete all as specified and directed

163

-

-

... More
S&F Double wall corrugated pipe coupler for pipe size 110/95 mm complete all as specified and directed

108

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.