Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 40,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_640623_1Bid Award Id
ViewTender No
8176/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(A) INCOMING:-
(i) MCCB 250 amps, 4 pole, breaking capacity 36 KA suitable for operation of 415 volts AC 50 HZ - 01 No,
(ii) 4 strip copper bus bar of rating 1.5 times current carrying capacity of incoming switch gear or not less than 350 Amp whichever higher
(iii) Digital Ammeter, 0-400 Amps,with 3 Nos CT and 4 Position selector switch-1 Set , (iv) Digital Voltmeter 0-500 Volts with 4 Position selector switch - 1 set ,
(v) LED Type indicator lamp R-Y-B (1 Set), (v) 4 strip aluminum coated copper bus bar of rating 1.5 times current carrying capacity of incoming switch gear or not less than 200 Amp whichever higher
(B) OUTGOING (i) MCCB 160 A, 3 Pole, 415 Volts, 25KA -02 No
(ii) MCB 4P 40 Amps-03 Nos
(iii) Space for one MCCB
-
-
-
Material and labour for appling of two coat of synthetic enamel spray painting (smoke grey/blue shade) after preparation of old LT Panel board and iron surfaces finishing of any description over 10 cm in width or girth including preparation old surface complete all as specified and directed .
165
-
-
Material and labour for preparation of old steel surface of street light pole & cross arm and applying one coats of aluminium paint( Black/yellow combition zebra marking) after preparation of old surface on street light pole of any description over 10 cm in girth or width complete all as specified and directed.
1378.15
-
-
Material and labour for preparation of old concrete surface of PCC pole and applying one coats of cement base paint on PCC HT electric pole( 11 m Height) from GL to 1.5 m height and old concrete surface of steel surface of cross arm and applying of one coats of aluminium paint of steel surface of steel member of PCC pole accessory and applying one coats of synthetic enamel paint( Black/yellow combition zebra marking) on above 1.5m height PCC light pole of any description over 10 cm in girth or width complete all as specified and directed.
100
-
-
Supplying, Laying of LT XLPE insulated armoured heavy duty cable 1100 volt grade ISI marked with alumimium conductor multi strand cross sectional area 6 Sqmm x 2 Core and including taking down existing cable complete all as specified and directed .
70
-
-
Supplying, Laying of LT XLPE insulated armoured heavy duty cable 1100 volt grade ISI marked with alumimium conductor multi strand cross sectional area 10 Sqmm x 2 Core and including taking down existing cable complete all as specified and directed .
100
-
-
Supplying, Laying of LT XLPE insulated armoured heavy duty cable 1100 volt grade ISI marked with alumimium conductor multi strand cross sectional area 10 Sqmm x 4 Core and including taking down existing cable complete all as specified and directed .
200
-
-
LT XLPE insulated armoured heavy duty cable 1100 volt grade ISI marked with alumimium conductor multi strand cross sectional area 16 Sqmm x 4 Core and including taking down existing cable complete all as specified and directed .
250
-
-
Supplying, Laying of LT XLPE insulated armoured heavy duty cable 1100 volt grade ISI marked with alumimium conductor multi strand cross sectional area 25 Sqmm x 4 Core and including taking down existing cable complete all as specified and directed .
150
-
-
Supplying, Laying of LT XLPE insulated armoured heavy duty cable 1100 volt grade ISI marked with alumimium conductor multi strand cross sectional area 35 Sqmm x 3 1/2 Core and including taking down existing cable complete all as specified and directed .
150
-
-
Supplying, Laying of LT XLPE insulated armoured heavy duty cable 1100 volt grade ISI marked with alumimium conductor multi strand cross sectional area 50 Sqmm x 3 1/2 Core and including taking down existing cable complete all as specified and directed .
200
-
-
Supplying, Laying of LT XLPE insulated armoured heavy duty cable 1100 volt grade ISI marked with alumimium conductor multi strand cross sectional area 70 Sqmm x 3 1/2 Core and including taking down existing cable complete all as specified and directed .
170
-
-
Supplying, Laying of LT XLPE insulated armoured heavy duty cable 1100 volt grade ISI marked with alumimium conductor multi strand cross sectional area 95 Sqmm x 3 1/2 Core and including taking down existing cable complete all as specified and directed .
120
-
-
Supplying, Laying of LT XLPE insulated armoured heavy duty cable 1100 volt grade ISI marked with alumimium conductor multi strand cross sectional area 120 Sqmm x 3 1/2 Core and including taking down existing cable complete all as specified and directed .
100
-
-
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out as in soft/loose soil.
300
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm as in soft/loose soil.
153
-
-
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level n. exc. 1.50 m above the starting point complete all as specified and directed.
99.75
-
-
Material and labour for Sand cushioning to the full width of trenches for protection of cables including punning down complete all as specified. Note :- Thickness of sand cushioning shall be the thickness after punning down.
81
-
-
Material and labour for Class designation 75 bricks, old size, flat, common clay laid in trenches across the trench as cable protection Complete all as specified and directed.
7900
-
-
Supply and laying un-reinforced precast concrete cable cover, class LV, type I flat size of 250 x 150 mm x 40 mm Complete all as specified and directed.
100
-
-
Material and labour for Plain Cement Concrete M-10(Nominal Mix) using 20 mm graded stone aggregate as in coping, bed plates, wheel guard & other similar work etc. including weathering, slightly rounded or chamfered angles and throating and necessary form work complete Complete all as specified and directed.
2
-
-
Material and labour for broken stone or boulders aggregate 40 mm grade for loose filling in all substation areas/around transformers/2/4 pole structures/LT FP boxes etc aComplete all as specified and directed.
50
-
-
Material and labour for GI steel tubing 40 mm bore, light grade for cable protection and laid in trenches all as specified and directed.
6
-
-
Material and labour for GI steel tubing 80 mm bore, light grade for cable protection and laid in trenches all as specified and directed.
12
-
-
Material and labour for GI steel tubing 100 mm bore, light grade for cable protection and laid in trenches all as specified and directed.
6
-
-
Material and labour for horizontal boring for 90 mm bore under road, pavement, hard standing at 0.9 m to 1.5 m depth from top of road level and insert 80 mm GI pipe with all necessary fittings and without any damages of road /pavement/ hard standing surface complete all as specified and directed.
20
-
-
Supply and fixing MCCB 400 amps, 4 pole, breaking capacity 36 KA suitable for operation of 415 volts AC 50 HZ with adjustable type all as specified in SSR Part -I including making necessary electric connections and including taking down existing one complete all as specified and directed .
2
-
-
Supply and fixing MCCB 250 amps, 4 pole, breaking capacity 36 KA suitable for operation of 415 volts AC 50 HZ with adjustable type all as specified in SSR Part -I including making necessary electric connections and including taking down existing one complete all as specified and directed .
2
-
-
Supply and fixing MCCB 160 amps, 4 pole, breaking capacity 36 KA suitable for operation of 415 volts AC 50 HZ with adjustable type all as specified in SSR Part -I including making necessary electric connections and including taking down existing one complete all as specified and directed .
2
-
-
Material & Labour for Steel tubular swaged poles complete with cast iron base plate finial taper plug, bolts, nuts and screws as specified type 410 SP-22(8.5 mtrs long ) and painting with 2 coats of aluminium paint over a coat of primer including taking dwon old pole complete all as specified and directed .
4
-
-
Supply and fixing in repair of Earth continuity conductor or main earthing lead, aluminum, 25 x 3 mm size, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required Complete all as specified and directed.
10
-
-
Supply and fixing in repair of Danger notice plate of 1.6 mm thick MS sheet for HT size 20x15 cm vitreous enamelled white, fixed with MS clamps, bolts and nuts Complete all as specified and directed.
50
-
-
Supply and fixing in repair of Anti climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole Complete all as specified and directed.
0.5
-
-
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI or steel wire 4 mm dia as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layer and including taking down existing one complete all as specified and directed .
10
-
-
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 32x6mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layer and including taking down existing one complete all as specified and directed .
10
-
-
Supply, laying in trenches/fixing on walls or in any other indicated situation, galvanized strip of size 32 mm x 6 mm connected to test point and including taking down existing one complete all as specified and directed .
11
-
-
Supply and fixing in repair of On load change over switch 125 Amps capacity, TPN, 415 volt complete all as specified and directed .
2
-
-
Supply and fixing in repair of On load change over switch 63 Amps capacity, TPN, 415 volt complete all as specified and directed .
2
-
-
Supply and fixing in repair of cable straight through for 1.1 KV grade cable joint complete with jointing material and accessorie suitable for two core XLPE armoured aluminium cable of size 6 to 16 Sqmm complete all as specified and as directed.
1
-
-
Supply and fixing in repair of cable straight through for 1.1 KV grade cable joint complete with jointing material and accessorie suitable for three and half/four core XLPE armoured aluminium cable of size 25 to 50 Sqmm complete all as specified.
2
-
-
Supply and fixing in repair of cable straight through for 1.1 KV grade cable joint complete with jointing material and accessorie suitable for three and half core XLPE armoured aluminium cable of size 70 to 150 Sqmm complete all as specified.
2
-
-
Supply and laying electric rubber matt, 2m x 1 m x 2.5 mm size, elastomer free from any insertion, combination of natural rubber and other synthetic polymers, conforming to IS -15652, tolerance upto ±10% on thickness, ±5% on length, ±2% on width,Class "B" upto 11 KV duly lSI marked all as specified and as directed.
5
-
-
Material and labour for trimming of branches of trees touching LT electric over head line and making clear about 3 mtr in radius by climbing up tree or by providing ladder, at a height 7 mtr and above and carrying and depositing where directed not exceeding 50 mtr complete all as specified and directed.
20
-
-
Supply and fixing in replacement of 3 Ph LED Ammeter Cl1 for LT Panel, flush mounting 96x96 mm with inbuilt selector switch complete all as specified and directed. Make : L&T Cat Part No. WL131010OOOO or equivalent model of make list as given in PS as approved
8
-
-
Supply and fixing in replacement of 3 Ph LED Voltmeter for LT Panel suitable for input voltage measurement range 50-550 VAC, flush mounting 96x96 mm with inbuilt selector switch complete all as specified and directed. Make : L&T Cat Part No. WL132010OOOO or equivalent model of make list as given in PS as approved.
5
-
-
Supply and fixing in replacement of ammeter selector switches for line current with off with CT. Make : L&T cat part No. 61325 SBB13TDYR or equivalent model of make list as given in PS as approved.
10
-
-
Supply and fixing in replacement of voltmeter selector switches for voltage between phases with OFF complete all as specified and directed. Make : L&T cat part No. 61312 SBB13TDYR or equivalent model of make list as given in PS as approved.
10
-
-
Supply and fixing in replacement of R Y B LED indicators (set of three indicators) having 16 mm dia with LVGP & Surge protection complete all as specified and directed. Make : L&T cat part No. SIL or equivalent model of make list as given in PS as approved.
9
-
-
Supply and fixing in replacement of4 pole power contractors suitable for 80 Amps AC rating complete all as specified and directed.
4
-
-
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ₹ ___________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
-
-
-