BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_674416_1Bid Award Id
ViewTender No
CWE/TEZ(N)/T-30 of 24-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply only Limit switch
2
-
-
Supply only Battery Charger input range 88-265 V AC and out put 24 V DC
2
-
-
Supply only spring charging mechanism of RMU IN V, 230 V AC
2
-
-
Supply only 3 Ph Volt meter with inbuilt selector switch
2
-
-
Supply only 3 Ph Ammeter with inbuilt selector switch
2
-
-
Supply only 11 KV RMU CT of Ratio 100-50/5-5 A, Class I, 15 VA
2
-
-
Supply only HT RMU cable boot assembly 11 KV grade
4
-
-
Dismantling and taking down existing unserviceable Gang operated switch complete including dropout fuse set from RCC / Steel tubular (Single/2Pole/3Pole/4Pole) pole structures complete all as specified and directed.
6
-
-
Dismantling and taking down unserviceable Lightining arrestors complete all as specified and directed.
4
-
-
Dismantling and taking down rusted / corroded Cross arms any shape and size from PCC/ Steel Tubular Poles including nut bolts clamps complete all as specified and directed.
2
-
-
Dismantling and taking down worn out Pin/Post insulators 11 Kv any shape and size from PCC/Steel tubular poles complete all as specified and directed.
36
-
-
M&L for Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of two coats of Aluminium Paint over a Coat primer, complete all as specified and as directed.
2
-
-
M & L for Composite Polymer Air Break Gang Operated for 11 KV grade, Triple Pole vertically mounted and fitted on steel frame suitabe for, current rating 200 Amps, mechanically operated mechanism consisting of Operating Rod of GI Pipe 25mm bore (dia) ‘light grade’ of suitable Length worked From Ground Level and with Locking Arrangement Mild Steel Flat Iron Clamp 50x6mm including Expulsion Fuse, Triple Pole, Channel type/ drop out type suitable as per Site requirement with Working Pressure 11 KV grade of capacity 50 to 100 Amps including taking down unserviceable Fuse , complete all as specified and as directed.
6
-
-
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth in soft / loose soil and getting out for removing / laying of pipe /Cables etc complete all as specified.
243
-
-
Returning, filling in , including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in soft/oose soil complete all as specified and directed.
167
-
-
Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the strating point complete all as specified and directed.
76
-
-
M&L for river sand, washed and screened dry for cushioning to under ground cable in tenches below and around under ground cable including spreading and levelling complete as specified and directed.
49
-
-
M&L for Boring / Drilling (Horizontally) manually/ mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified and directed.
40
-
-
Supplying and laying un-reinforced precast concrete cable cover class HV, type - I, flat, size 300 x 180 x 40 mm all as specified and directed.
1348
-
-
Dismantling and taking down unserviceable/faulty HT UG cable for fault finding or replacing from pole or in trench all as specified and directed.Note 1.Excavation work will be measured and paid separately under respecive item of schedule. 2. Serviceable cable and PCC cable cover shall be relaid under relevant item of this schedule.
750
-
-
M&L Relaying of serviceable UG Cables of any size obtained from above item No 18 in trenches/poles/walls complete all as specified and directed. .NOTE : Earthworks, Sand Cushioning, New PCC cable cover, GI Pipe, etc. will be measured and paid under appropriate Items.
400
-
-
M&L relaying of serviceable PCC cable cover obtained from taking down cable all as specified and directed by Engineer-in-charge.
1760
-
-
Supply & laying HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, conforming to IS:7098 (Part II), 11 KV, ‘Earthed Grade, cross-sectional area 95 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing, complete all as specified and as directed.
NOTE : Earthworks, Sand Cushioning, PCC cable cover, GI Pipe, etc. will be measured and paid under appropriate Items.
350
-
-
Supply and fix in repair Cable jointing kit for 11KV Earthed grade cable for Outdoor End termination Heat shrink type complete with Jointing material and acceesseries suitable for 3 core are XLPE armoured at conductor cable of size 120 sq mm all as specified and directed by Engineer-in-charge.
4
-
-
Supply and fix in repair Cable jointing kit for 11KV Earthed grade cable for Outdoor End termination Heat shrink type complete with Jointing material and acceesseries suitable for 3 core are XLPE armoured at conductor cable of size 95 sq mm all as specified and directed by Engineer-in-charge.
4
-
-
Supply and fix in repair Cable jointing kit for 11KV Earthed cable for Indoor end termination kit, Heat shrink type complete with Jointing material and acceesseries suitable for 3 core are XLPE armoured at conductor cable of size 95sq mm all as specified and directed by Engineer-in-charge.
4
-
-
Supply and fix in repair Cable jointing kit for 11KV Earthed grade cable for Indoor End termination Heat shrink type complete with Jointing material and acceesseries suitable for 3 core are XLPE armoured at conductor cable of size 120 sq mm all as specified and directed by Engineer-in-charge.
4
-
-
Supply and fix in repair Cable jointing kit for 11KV Earthed grade cable for Outdoor Straight through joint, Heat shrink type complete with Jointing material and acceesseries suitable for 3 core are XLPE armoured at conductor cable of size 95sq mm all as specified as directed by Engineer-in-charge.
2
-
-
Supply and fix in repair Cable jointing kit for 11KV Earthed grade cable for Outdoor Straight through joint, Heat shrink type complete with Jointing material and acceesseries suitable for 3 core are XLPE armoured at conductor cable of size 120 sq mm all as specified as directed by Engineer-in-charge.
2
-
-
S&F of composite polymeric Lightning Arrester Expulsion type complete with all Fittings Transmission Class discharge capacity 65 KA suitablefor working pressure of 11000 Volts including earth strip , complete all as specified and directed.
6
-
-
M & L for loose filling aggregate 40 mm, complete all as specified and directed.
20
-
-
Dehydration/ filtration of transformer oil of Capacity 50 KVA to 2 MVA with ultra high vacuum filteration machine and checking dielectric strength (BDV) all as specified .Refilling the transformer oil in the shell of transformer after carrying out filtration and heating up oil to achive reqd dielectric strength up to 60 KV with 2.5 mm Gap and submitting the test result before and after filteration of oil in presence of Engr- in- charge on proper proforma duly signed.
8000
-
-
Supply and fill Transformer oil with high viscosity , high resistance to oxidation & thermal stability mainting BDV Value of 55-60 KV in 2.5mm rod gap complete all as specified and directed by Engineer-in-charge.
600
-
-
S & F dehydrating breather for 50-160 KVA transformer with dehydrating agent (Silica gel) including taking down existing breather complete all as specified.
5
-
-
All as per Item above , but for 200-250 KVA transformer
4
-
-
All as per Item above, but for 400 KVA transformer
2
-
-
M&L for Strip opening of transformer of capacity 50 to 160 KVA, 11 KV /433 volts indoor /outdoor type of any make after unscrewing nuts & bolts, screws and connected accessories such as breather, conservator tank, temp gauge etc. for replacement of defective parts such as replacement of leaking gaskets, replacement of worn out/burnt out studs, checking and cleaning of contacts of tap changer and re-assembling the transformer after replacing the defective parts/repair complete all as directed. Notes : (i) Payment of defective parts to be replaced shall be measured and paid for separately under respective item of this schedule.
(ii) The repair/strip opening of transformers shall be carried out at site of its installation without taking down/removal of transformer from the site of installation..
3
-
-
All as per item above but for transformer 200 KVA to 400 KVA.
3
-
-
Supply only in replacement ceramic bushing and brass spindle for terminal on HT side threaded complete with nut, washers etc of suitable diaon HT side of transformer of capacity 50-160 KVA
4
-
-
All as per Item above, but for 200-250 KVA transformer
3
-
-
All as per Item above, but for 400 KVA transformer
2
-
-
All as per Item above, but for LT side of 50-160 KVA transformer
4
-
-
All as per Item above, but for 200-250 KVA transformer
4
-
-
All as per Item above, but for 400 KVA transformer
2
-
-
Supply only in replacement of complete gasket (Cork sheet) 6 mm thick complete of capacity of following transformer including conical rubber bush for Transformer of capacity 50-160 KVA
3
-
-
All as per Item above, but for 200-250 KVA transformer
2
-
-
All as per Item above, but for 400 KVA transformer
1
-
-
Material and labour for painting to 50-160 KVA transformer scrapping and removing oil paint and applying 02 coats of synthetic enamel paint by taking due care for HT/LT side supply all as specified and directed by Engineer-in-charge .
3
-
-
All as per Item above, but for 200-250 KVA Transformer
4
-
-
All as per Item above, but for 400 KVA Transformer
2
-
-
Disconnecting all in coming and outgoing cables, removing the transformer of capacity 100-400 KVA from the platform / two pole structure / floor and loading it in the vehicle carefully using crane and transporting it to the contractor's workshop, carry out the required repairs and transport the transformer back to the site , install it, reconnect all the incoming and out going cables by properly crimping using lugs of suitable size lugs, taping the LT / HT bushes / bus bars, using LT / HT insulation tape and testing complete of following capacity all as directed by Engr-in-Charge Note :- (a) Shifting and fixing transformer from own arrangent temporarily from MES Area to that area ( Back up Transformer will be provided by MES) (b) The cost of transportation of 2 transformers between Existing location and the Workshop is deemed to be included in the unit price. (b) Gasket set, LT/HT side porcelein / ceramic bushing, spindle for HT/LT side , rewinding, dehydration of oil (if required) shall be measured and paid separately in respective items.
1
-
-
Supply and winding of 11/0.433 KV HV coils,using new copper wire/strip of proper size including insulating materials (double insulation)as per existing size of core of transformer complete including heating , varnishing complete all as specified and directed
40
-
-
Supply and winding of 11/0.433 KV LV coils,using new copper wire/strip of proper size including insulating materials (double insulation)as per existing size of core of transformer complete incl heating , varnishing complete all as specified and directed
30
-
-
M & L for reinsulation of 11/0.433 KV HV/LV coils coils,removing U/S insulating materials, double reinsulation with insulating papers using same copper strip and rewinding as per existing size of core of transformer complete incl heating , varnishing complete all as specified and directed
10
-
-
Materials and labour for replacement of silica gel of breather including providing silica gel as per the existing size / model complete all as specified and directed.
2
-
-
Materials and labour for replacement of temperature gauge as per the existing size / model complete all as specified and directed.
4
-
-
Material & Labour for 32 mm dia gunmetal drain valve of transformer as per existing one complete all as specified and directed.
2
-
-
Supply & fixing GI Pipe light grade 80 mm dia, ISI marked, of required length for protection of cables complete including necessary MS clamps, nuts, bolts and washers etc complete all as specified and directed.
18
-
-
S & F in repair composite polymer type pin insulator for 11 KV overhead line including all its accessories complete all as specified.
18
-
-
S & F in repair composite polymer type post insulator for 11 KV overhead line including all its accessories complete all as specified.
18
-
-
Material and labour for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in foundations, filling and mass concrete for poles / stays complete all as specified and directed.
2
-
-
M & L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate as 100 mm thick in sub floors and sub base floors and paving complete all as specified and directed.
20
-
-
M&L for Servicing and painting of 11 KV GOD by cleaning the contact ,Pin/post insulator with CTC and applying the Patrollium Jelley at the contact point /down rod links for smooth operation including replacing the rusted /corroded bolts and nuts(using GI Nuts& Bolts)and defective insulator of GOD as required at site. Painting shall be done by after preparing/scrapping the metal surface with emery sheet in all respect and painted with one coat of primer and two coat of aluminium paint including cross arm/MS channel and male female contact in red/yellow/blue colour Note:-Male/female contactors,copper jumper ,etc shall be measured and paid under relevant items
10
-
-
Supply only Male Contact/ moving contact blade of Air Break Switch 11 Kv complete all as specified and directed.
6
-
-
Supply only Female contact/ fixed contact Jaw of Air Break Switch 11 Kv complete all as specified and directed.
6
-
-
Supply only Tinned copper flexible jumper 200A A site selectableof Air Break Switch 11 Kv complete all as specified and directed.
9
-
-
Labour for restringing/tilting, clamping, bending, jumpering etc to remove excess sag of loose ACSR overhead line using essential T&P such as manila rope, puller and teipod etc upto permissible sag between two poles continuously upto termination point. Note- 1. Three runs of ACSR shall be measured as one unit. 2. Span Between two consecutive poles shall be measured as one unit upto 80 mtrs. 3. The cost of use of required tools and safety equipments is deemed to be included in this unit price.
10
-
-
Labour for trimming/cutting to small tree branches girth not exc 30cm upto minimum 2 Mtr clearance, tightening to stay stand in proper angle complete all as specified and directed by Engr in charge. Note- 1. Span Between two consecutive poles shall be measured as one unit. 2. The cost of use of required tools and safety equipments is deemed to be included in this unit price.
10
-
-
Material and labour for painting to steel tubular pole 11.0 metre long with two coats of synthetic enamel silver up to below 1.5M from Top edge and 1.50 metre height from ground level in 30 cm alternative black and red strips and remaining portion with alluminium paint incl numbering of pole no by stensils and MS frames like channel,clamps, angle, D-clamps etc with two coats of aluminium paint complete all as specified and directed.
30
-
-
Supply and fix danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with M S Clamps, bolt and nut approved size for HT poles, 25x25cm size including taking out old unserviceable danger notice plate complete all as specified and directed.
10
-
-
Materials and Labour for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5M below normal ground level connected to galvanised steel strip 32 mm x 6mm by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm (Reinforced with 8 mm dia. TMT bars @ 150 mm, center to center both ways) with one handle for lifting made out of 8 mm dia. MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing light grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown on electrical plate No 3 of SSR Part-I (2009) complete as specified and directed.
Note: (i) If sand found in the depth of 2.25 M during excavation agricultural soil to be filled after removal of sand the cost shall be deemed be included the quoted rate.
(ii) Earth test report shall be submitted by contractor duly signed.
12
-
-
M&L for GI strip 32x6 mm as earth continuity lead beyond test point fixed to wall on batten or recess or chases or buried in ground or drawn in conduit pipe complete all as specified and directed.
30
-
-
Cutting of green growth and wild grass by manual labour or by machine at electrical installation premises,around the pole,along the fencing,removing rubbish from the site of work and depositing where directed not exc 100 Mtr from the starting point. complete all as specified and directed. Note :- The item shall be operated as and when required in the entire period of the contract and the measurement will be taken every time independently for the payment.
2000
-
-
Supply & Fix in replacement syntheic mat of size 2m x 1m x 2.5 mm including taking out old Unseveciable Syntheic mat all as specified and directed by Engineer-in-charge.
2
-
-
S & F in repair cable route markers made out of PCC (1:3:6) type C1 using 20mm graded stone aggregate size 900 x 300 x 100 mm thick (60 cm buried in ground with "DANGER/11 KV UG CABLE MES" embossed on marker including excavation and earth work complete all as directed.
10
-
-
M&L Paint to existing HT bus bar chamber of any type complete with two coat of weather proof synthetic enamel paint after preperation of the surface by scrapping emery paper complete all as directed by Engr-in-Charge.
50
-
-
Dismantling of old jumper,including supply and fixing new HT XLPE insulated 11 KV grade aluminium jumper 120 sqmm connection not less than 2 mtrs including cable lugs,nut bolts and washer completeincluding testing on completion all as specified and directed by Engr- in -Charge.
10
-
-
M & L for Taking down transformer oil level indicator assembly from conservator Tank of transformer 50 KVA to 400 KVA Capacity from posn for making visibility of oil level by lowering oil level in conservator including cleaning thoroughly changing of gasket and acrylic sheet fixing back in posn refilling the removed oil as specified and directed by Engr-in-Charge.
2
-
-
Supply, install, testing & commissioning of HT busbar chamber CPRI approved of size (0.90x0.90x0.9)m , outdoor type, 7 tank processed factory fabircated CRCA sheet powder coated of 3.15 mm thickness, indoor plates 2mm thick, angle iron of size 50X50X6mm thick of length 0.6 m from pcc, frame work and tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete comprising of following :- BUS-BAR AND CABLE ENTRY
(a)The bus-bars shall be made up of 03 Nos Aluminium 200 A rated not less than 32mmx6 mm, (b)The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables.
6
-
-
Notes:-
(i) Danger notice plate of size 25 x 20 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for HT conforming to IS-2551 - 02 Nos.
(ii) Design / Drawing / BOM of the HT Busbar panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier.
(iii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
-
-
-
M&L for dismantling PCC two pole structure after taking out GOD, LA, channels including nuts and bolts carefully for refixing after erection of HT pole obtained from item No 84 all as specified and directed by Engineer in charge.
2
-
-
M&L for dismantling carefully HT pole 11 mtr height and refixing the same at anywhere under AOR of AGE E/M Solmara cantt including excavation, PCC work,T&P for shifting of the pole,etc all as specified and directed by Engineer-in-charge.
4
-
-
NOTES:
1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.
2. The rates for RCC/PCC shall deemed to include the cost of formwork, shuttering etc., required for complete and proper execution of the item. Refer Schedule "A" notes for details.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements