BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 37,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_MES_257357_1Bid Award Id
ViewTender No
8103/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling stone slab / tiles of any description or thickness in floors, aprons etc. Laid dry and pointed complete all as specified and directed.
16.5
-
-
Taking down cement plaster of any description on brick walls , concrete surfaces including racking out joints, hacking for key, scrubbing down with water, remove dust, debries/rubbish etc completer all as specified and as directed
167
-
-
Taking up or down steel tubing 15 mm bore (dia) and connections, segregating the serviceable pipes and connections, stacking properly at site(s) and keep in safe custody for re-use, complete all as specified and as directed
24
-
-
Taking up or down steel tubing 20 mm bore (dia) and connections, segregating the serviceable pipes and connections, stacking properly at site(s) and keep in safe custody for re-use, complete all as specified and as directed
16.8
-
-
Dismantling of wall and ceiling board or insulation boards/ slabs/ blanckets /any thickness and any description including cover fillets complete all as specified and directed.
40
-
-
Demolition reinforced cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and as directed
1
-
-
Demolition brick work build in cement mortar including all quoins, Arches, Pillars etc of any description complete all as specified and as directed
1
-
-
Material and Labour brick work with sub class 'B' Bricks (with old size Bricks), straight or curved on Plan exc 6.0 Metre mean radius, build in Cement Mortar 1:6 complete all as specified and as directed
1
-
-
Material and Labour for joint free non-skid ceramic colour tiles 600 x600, 7-8 mm thick, in floors etc set and jointed in neat cement slurry and pointed with white or coloured to match with tile laid over and including screed bed or bedding layer 15 mm thick in CM (1:6) complete all as specified and directed
250
-
-
Material and Labour for joint free non-skid ceramic colour tiles 600 x600, 10 mm thick, on vertical surfaces of wall such as skirtings etc set and jointed in neat cement slurry and pointed in white cement to match with tiles over and including 10 mm thick rendering in CM (1:4) complete all as specified and directed
21
-
-
Material and Labour for joint free non-skid ceramic colour tiles 400 x400, 07 to 08 mm thick in floors etc. set and jointed in neat cement slurry and pointed with white or coloured to match with tile laid over and including screed bed or bedding layer 15 mm thick in CM (1:6) complete all as specified and directed.
10
-
-
Material and Labour for joint free glazed ceramic colour tiles 450 x 300, 07 to 08 mm thick, on vertical surfaces of wall such as dados, skirtings etc set and jointed in neat cement slurry and pointed in white cement to match with tiles over and including 10 mm thick rendering in CM (1:4) complete all as specified and directed
75
-
-
Material and Labour machine cut kota stone slab flooring 20-25 mm thick, size not less than 550 x 550mm over & including 15 mm thick screed bed or bedding layer in CM 1:6 as in floor laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing with mirror polish complete all as specified and directed
140
-
-
Material and labour kota stone slab 20-25 mm thick in riser of steps, skirting, dedo and pillar laid over and including 10mm cement screed plaster in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing & including necessary bull nosing complete all as specified and as directed by the Engineer-in-Charge
15
-
-
Material and labour 20 mm thick granite (of any type) work (table rubbed and polished) in cooking platforms in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
10
-
-
Material and labour rendering 15mm thick in cement mortar 1:6 on Internal fair faces of brick walls or on concrete surfaces, finished fair and even complete all as specified and as directed.
50
-
-
Material and labour rendering 15mm thick in cement mortar 1:4 on External fair faces of brick walls or on concrete surfaces,plastered surfaces finished fair and even complete all as specified and as directed.
97
-
-
Material and labour rendering 5mm thick in cement mortar 1:3 on concrete surfaces of ceiling, etc, plastered surfaces finished even and smooth, without using extra Cement, complete all as specified and as directed
20
-
-
Material and labour for preparation of new plastered surface of wall applying two coats of Exterior Acrylic Emulsion paint over a coat of alkali resistant primer, complete all as specified and directed
97
-
-
Material and labour for complete removal of existing treatment of old plastered surface of wall and applying two coats of Exterior Acrylic Emulsion paint, complete all as specified and directed.
430
-
-
Material and labour for preparation of newly plastered surface of wall and apply two coats of oil bound distemper over a coat of 1 mm average thick wall putty, all as specified and directed.
50
-
-
Material and labour for complete removal of existing treatment of old plastered surface of wall and applying two coat of Acrylic washable distemper over a coat of 1mm average thick wall putty white cement base (J K Birla) and making smooth finish, complete all as specified & directed
1310
-
-
Material and labour for preparation of old plastered surfaces of ceiling an applying one coats of white wash complete all as specified and directed.
565
-
-
Material and labour preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
20
-
-
Material and labour for preparation of old painted wooden surfaces of any description over 10 cm width of girth & applying one coat of synthetic enamel paint of approved quality, tint to achieve glossy finish complete all as specified and directed
85
-
-
Material and labour for prepration of old painted steel surfaces of any description over 10 cm width or girth & applying one coat of synthetic enamel paint of approved quality, tint to achieve flossy finish, complete all as specified and directed.
60
-
-
Material and labour for RCC (nominal Mix) Type A1 1:11/2:3 (20 mm graded aggregate) as slabs supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified.
0.5
-
-
Material and labour for RCC (Nominal Mix) Type A1 1:1 1/2:3 (20 mm graded aggregate) as in chajja and Lintel etc complete all as specified
0.5
-
-
Supply and fix TMT bars 10 mm dia and over cut to length, bent to shape as required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
30
-
-
Supply and fix TMT bars 6 to 8 mm dia (confirming to Fe-410-S or Fe-410-0) cut to length, bent to shape as required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and as directed.
10
-
-
Material and labour formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick Flat, rough finished surface of concrete, complete all as specified and as directed
5
-
-
Material and labour form work to chajja and similar work; flat, rough finished surface to concrete complete all as specified and as directed
6
-
-
Supply and fix factory made uPVC white coloured Casement (Openable) door made of extruded profile with wall thickness of 2.3 mm (+/- 0.2mm). Window profile with hollow sectin with multi chamber Frame (60 x 58mm), Sash (60x 78mm) profile ( one vertical length in between two shutters) (60 x 74 mm) Glazing Bead (35 x 20 mm) will be mitered cut and fusion welded at all corners including drilling of holes for fixing Hardware and drainage of water etc making arrangement for fixing of Hardware. EPDM Gasket 1.2 mm (+/- 0.2mm thick, galvanised steel frame ( 28 x 21.5 mm), sash (31 x 27 mm), T-profile (27 x17mm) to be inserted in required profile, Frame will be fixed in the wall with 8 x 100 mm long Fasteners. Hardware : Casement door handle of zinc alloyed (white powder coated). Corner striker, secondary strikers, Cylinder, door transmission gear made to mild steel with multi point locking system with strikes 3D hinges of zinc alloyed ( white powder coated) and 5mm thick glazing with selected quality glass. Note :- The unit rate quoted by the contractor excludes cost of glass and including all connecting accessories. Net opening will be measures for payment purpose.
3
-
-
Supply and fix factory made uPVC white coloured sliding window Two track made of extruded profiles with wall thickness of 2.3 mm (+/- 0.2mm). Window profile with hollow section with multi chamber Frame (60 x 62mm), Sash (42x 67mm) Sliding Interlock ( One vertical length in each shutter) 45.5 x 28 mm) Glazing Bead (21.5 x 16mm) will be mitered cut and fusion welded at all corners including drilling of holes of fixing Hardware and drainage of water etc making arrangement for fixing of Hardware. EPDM Gasket 1.2 mm (+/- 0.2mm thick, galvanised steel frame ( 30 x 21.5mm), sash (30 x 18 mm), Profile to be inserted in required Profile frame will be fixed in the wall with 8 x 100 mm long fasteners Hardware : Touch Lock of zinc alloyed (white powder coated ) steel roller system including 5.5mm thick sheet glass tinted or selected quality,Aluminium Track on Bottom Rail for Two Track sliding Frame wool pine for sliding sash and interlock, complete all as specified and as directed. Note :- The unit rate quoted by the contractor excludes cost of glass and including all connecting accessories. Net opening will be measures for payment purpose. (a) Area not exceeding 2.00 Sqm each
3
-
-
Supply and fix false ceiling with Everest Fibre Cement Designer tile Ivory painted (High Pressure Steam Cured) of 4mm thickness (as per IS : 14862) of size 595 x 595 mm and any one of the design ( occeanic lake & hill, cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of maint "T" runner with suitably spaced joints to get required length, and 15 x 32 mm made from 0.30 mm thick sheet and cross 'T' of size 15 x 32 mm made of 0.30 mm sheet, spaced between main 'T' at 600 mm c/c to form a grid of 600x 600 mm and wall angle of size 15x20mm made of 0.30mm thick sheet and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grill, light fittings, fixtures, smoke detectors etc. Maint 'T' runners to be suspended from ceiling using GI soffit cleats fixed to existing rafter, purlin, etc with dash fasteners, GI adjustable rods fo 3mm dia with gavanised butterfly level clips, spaced at 1200 mm c/c along main T, bottom exposed width of 15 mm of all T sections shall be centra black pre-painted with polyester paint and having a load bearing capacity of 12 Kg/sqm all complete at all heights as per direction of Engineer-in-Charge.
40
-
-
Supply and fix steel ventilator with top hung shutters including hinges steel peg stay, complete all as directed
4
-
-
Material and labour for mild steel framed guard bars of 12 mm square conforming to Fe-290 (Grade 165-E) welded to steel ventilators/windows complete all as specified and directed
72
-
-
Hacking out old broken glass (any thickness, size quality or description) from wooden frames or stone or concrete or brick surrounds, glazed with putty or fixed with beads all as specified and directed.
10
-
-
Material and labour sheet glass, 3.0 mm thick glazing with beads or oil putty, not exc. 0.50 square metre in each pane complete all as specified and as directed.
12
-
-
Supply and fixing solid PVC door frame of size 50mm x 47 mm made out of 5 mm wood grain printed PVC sheet & edges will be painted to match with printed sheet as reinforced with M S square tube and fixing in opening as per specification & drawing complete all as specified and as directed by the Engineer- in- charge
20
-
-
Supply and fix factory made solid PVC moulded door shutter with wood free EPS, 28 to 30 mm thick (stiles with 2,4,6 raised panel design with 2mm thick 3 D wood grain moulded PVC sheet polyurethane painted on the front face & 2 mm thick plain colour PVC sheet on back face, fixing in frame at site as per specification & drawing complete all as specified and as directed by the Engineer-in-Charge.
8
-
-
Supply and fix stainless steel butt hinges, medium weight, cold rolled ISI Marked of size 100 mm complete all as specified.
18
-
-
Supply and fix aluminium Tower bolt 150 mm long , fixed , complete all as specified and as directed
12
-
-
Supply and fix 150 mm long aluminium handle fabricated type complete all as specified & directed
12
-
-
Supply and fix in repair 20mm dia aluminium anodised, tubular curtain rail fancy type complete all as specified and as directed by the Engineer-in-Charge.
50
-
-
Supply and fix 20 mm dia, aluminium anodised, brackets for tubular curtain rail, fancy type complete all as specified and as directed by the Engineer-in-Charge.
50
-
-
Material and labour 15 mm dia bore steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
12
-
-
Refixing old steel tubing 15 mm bore (dia) ad connections in new or old position ( walls, ceiling, Floors etc) including cleaning both inner and outer surfaces of pipes by using wire brush including provision of new GI connections (as required ordered at sites), complete all as specified and directed
12
-
-
Material and labour for 20 mm dia bore steel tubing medium grade galvanised with all fittings and fixed complete to walls as ceiling or laid in floors
8.8
-
-
Refixing of old steel tubing 20 mm bore(dia) and connections (serviceable pipe and connections in new or old position( walls, ceiling , Floors etc) including cleaning both inner and outer surfaces of pipes by using wire brush including provision of new GI connections ( as required ordered at sites) complete all as specified and as directed
8
-
-
Supply and fix Bib Tap 15mm bore (dia), Cast copper Alloy, Fancy type chromium plated with Crutch or Butterfly Handle, screwed down, screwed for Iron Pipe or for Brass ferrule and fixed in repairs, complete all as specified and as directed.
6
-
-
Supply and fix in repair single lever basin mixer with popup waste and 450mm long braided hoses, fancy type, cast copper alloy, chromium plated, complete all as specified and directed. Cat part No. LYR-38051B, Make Jaguar
5
-
-
Supply and fix glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and directed.
5
-
-
Supply and fix looking mirror of size 600X450mm bevelled edge of selected quality Atul Make or equivalent mounted PVC frame and fixed to and including wooden plugs with chromium plated brass screws cup washer complete all as specified
4
-
-
Supply and fix stop valve 15 mm bore (dia) , cast copper alloy, fency type chromium plated screwed down height pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed-in-repairs, complete all as specified and as directed.
2
-
-
Supply and fix in repair angular stop cock 15 mm bore fancy type chromium plated concealed type screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. Make : Somany cat No 210308
2
-
-
Supply and fix in repair vitreous china squatting pan and trap ' Orissa' Pattern, size 580 x 440 mm white, with integral foot rests including connection to drain and pipe ( excluding flushing cistern and flush pipe) complete all as specified and as directed by the Engineer -in- Charge.
1
-
-
Supply and fix vitreous china white wash down water closet Pan (Pedestal Pattern) with trap and fixing bolts (excluding flushing cistern and flush pipe) including connection to drain ( or outgoing pipe) and to flushing pipe, anti syphonage pipe, etc and making good to floor/ disturbed surfaces including dismantling the existing unserviceable water closet complete all as specified and as directed.
1
-
-
Supply and fix in repair, white plastic water closet seat and cover for water closet pan( Pedestal Pattern), closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device, complete all as specified and as directed.
1
-
-
Material and labour for PVC flushing cistern 10 litre capacity white, low level , valve less, syphonic action type with Inlet, ball valve, float and handle, a pair of cast iron brackets erecting stand duly painted including cutting and pinning in ends, making good disturbed surfaces in cement Mortar 1:3 and fixed - in repairs, complete all as specified and as directed
2
-
-
Supply and fix in repair wash basins vitreous china, coloured 550 x 400 mm oval type , ivory colour, fixed, complete all as specified and directed.
5
-
-
Supply and fix sink made of stainless steel 1.0 mm thick kitchen or laboratory overall size 495 mm x 420 mm bowl size 410mm x 330 mm x 160mm with plugs, wahsers and wastes, etc. Including bedding in Cement Mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe and fixed in repairs complete all as specified and as directed.
1
-
-
Supply and fix PVC connection 15 mm size with PTMT Nuts of length 450 mm and fixed in repairs, complete all as specified and as directed.
7
-
-
Supply and fix in repairs 32 mm bore PVC waste pipe 600 mm to 750 mm long with one end socketed of approved quality all as specified and directed
6
-
-
Supply and fix brass chromium plated shower rose 125 mm size, with or without swivel joints, and fixing to steel pipe or union an fixed in repairs complete all as specified and as directed.
1
-
-
Supply and fix brass chromium plated tubular towel rail, 20 mm dia 'D' Type, 60 CM long between flanges with bracket complete all as specified and as directed.
5
-
-
Material and labour for servicing of existing steel windows/ ventilator by removing rust from hinges and greasing/oiling moving parts, welding damaged/broken portion if any retaightening etc including providing putty for existing glass panes complete.
25
-
-
Taking down existing urinal from site and refixing the same after tilling work, complete all as specified and directed.
2
-
-
Supply and fix PVC (SWR) 75mm bore dia soil, waste and ventilating pipe , singe socketed, in any length with rubber ring joints fixed to walls including taking up/down unserviceable pipe, fittings, etc, complete all as specified and as directed
4
-
-
Supply and fix PVC (SWR) 110mm bore dia soil, waste and ventilating pipe , single socketed, in any length with rubber ring joints fixed to walls including taking up/down unserviceable pipe, fittings, etc, complete all as specified and as directed
4
-
-
Supply and fix PVC (SWR) 75mm bore dia, bend any type, provided with access door, etc and jointing with solvent cement and fixed-in - repairs, complete all as specified as directed
2
-
-
Supply and fix PVC (SWR) 110mm bore dia, bend any type provided with Access Door, etc and jointing with solvent cement , and fixed-in-repairs, complete all as specified and as directed.
2
-
-
Supply and fix PVC (SWR) 75mm dia, Branch piece, single (Single Y) Equal or Unequal with Access Door etc jointing with solvent cement and fixed-in - repairs, complete all as specified as directed
1
-
-
Material and labour for providing precast reinforced cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in louvres & jallies 95 mm thick including all mouldings, set in CM 1:4 complete all as specified
10
-
-
Supply only sheet glass, selected quality, 5.5 mm in squares not exceeding 0.5 sqm each pane, complete all as specified and directed
4
-
-
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder,ceiling roses, regulators, switch socket outlet, bulk head fittings, tube light fittings etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and directed.
199
-
-
Taking down carefully by unscrewing from board/outlet boxes, fittings and fixture such as main switches & DBs of any size and any capacity and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and directed.
7
-
-
Taking down the existing unserviceable sub main wiring of any type/description as existing at site including making good the disturbed surfaces to match with the existing finished complete all as specified and directed.
175
-
-
Material and Labour for Point wiring with 1.5 sq mm copper conductor single core flame retardant PVC insulated unsheathed 1100 volts multistranded drawn through and including PVC Rigid concealed conduit medium grade of suitable size ISI marked and pressed steel terminal boxes of 1.22 mm thick MS of suitable sizes duly painted with red oxide metal primer including fixing/grouting sunken as per site requirement provision of 3mm thick ISI lamination hylem sheet for mounting the switches , sockets, regulators etc including running up of 1.5 sqmm copper conductor flame retardant PVC insulated cable as earth continuity conductor alongwith wiring and connecting to the common earth dilly all as specified for one light point controlled by one, one way switch 6 Amps.
101
-
-
All as per item No 82 here-in-before but for one ceiling fan/Exhaust fan point controlled by one way switch and regulator
27
-
-
All as per item No 82 here-in-before but for one 3 point 6 Amps socket outlets point controlled by one switch on the same board
12
-
-
All as per item No 82 here-in-before but for one 3 pin 6 Amps socket outlet point controlled by one switch on independent board
36
-
-
All as per item No 82 here-in-before but for one bell point controlled by one, one way switch 6 Amps
2
-
-
All as per item No 82 here-in-before but for one light point controlled by one, two way switch 6 Amps
1
-
-
All as per item No 82 here-in-before but for using 2.5 Sqmm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 Amps switch socket combination point including running of 1.5 sqmm copper conductor flame retardant PVC wire as earth continuity conductor alongwith wiring and connecting to the common earth dolly
20
-
-
Supply and Fix modular switch one way 6 Amps one module
176
-
-
Supply and Fix modular switch one way 16 Amps one module .
20
-
-
Supply and Fix modular bell push one way 6 Amps one module
2
-
-
Supply and Fix modular switch two way 6 Amps one module
2
-
-
Supply and Fix modular socket 6 Amps 2/3 pin combined two module
48
-
-
Supply and Fix modular socket 16 Amps 2/3 pin combined two module
20
-
-
Supply and fix ceiling rose surface bakelite 65 x 50 mm two to three terminals AC 230 volts complete all as specified and directed.
113
-
-
Supply and fix ceiling fan regulator step type, 120 watt 2 module as required, complete all as specified and directed.
21
-
-
Supply and fix lamp holder, insulated body, with back plate for angular batten fittings with one PVC block of size 75mmX75mm for mounting the fitting including 10 watt LED lamp cat no LHLDERHEMD8X010 MAKE HAVELLS or equivalent in Bajaj & crompton complete all as specified and directed.
7
-
-
Supply and fix sheet metal enclosures for DBs (Double door type) when MCB TPN 4 way with 200 Amps 415 Volts rated bus bar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection complete all as specified and directed.
1
-
-
Supply and fix sheet metal enclosures for MCBDB SPN 2 way with 200Amps rated bus bar 240 Volts double door with magnetic locking system complete all as specified and directed.
6
-
-
Supply and fix MCB TPN/4 FP 415 Volt suitable for fixing in MCB DB of capacity 40/60 Amps complete all as specified and directed. Make : L&T Cat Part No BB40400B, or equivalent as approved by GE,
1
-
-
Supply and fix SPN/DP 230 Volt suitable for fixing in MCB DB of capacity 40 Amps complete all as specified and directed. Make : L&T Cat Part No BB203206, or equivalent as approved by GE
6
-
-
Supply and fix MCB SP 230 Volt suitable for fixing in MCB DB of capacity 6 to 32 Amps complete all as specified and directed. Make L&T Code order No BB10320C, Havells & Legrand
46
-
-
Supply and fix SPN enclosure with two pin and earth plug and socket with 240 Volt 20 Amps SPN MCB including removal old UNSV complete all as specified and directed
1
-
-
Supply and fix wall mounted LED 18 watts, box type (decorative) light fitting, 230 volt with extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver connector block etc with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from celling rose to fitting including LED tube 4' x 18 watts complete all as directed by Engineer-in-Charge. Make :- Havells, Cat part No LHLDCLXEUL83018, LHFYBPNIA1W022 or equivalent in Bajaj & Crompton.
80
-
-
Supply and fix recess mounting flat panel 36 watt LED fitting (2' x 2') for armstrong/ grid ceiling, white powder coated CRCA housing complete with full window acrylic diffuser & electronic driver, high brightness SMD LEDs etc complete with all accessories internally prewired and necessary mounting arrangements, complete all as specified and as directed. Make : Bajaj Model BZRSQL 36 W GZ1 WH or equivalent in Havells & Crompton.
8
-
-
Supply and fix Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 Watts with pre wired and necessary mounting arrangement provision of new 3 core multistanded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as directed by Engineer-in-Charge. Make :- Havells Cat part No LHETBXU7PA6S025 or equivalent in Bajaj,& Crompton.
6
-
-
Taking down ceiling fan of any sweep, keeping with safe custody and hanging/fixed in repair the same with replacement of UNSV PVC insulated PVC sheathed 3 core multistandard copper conductor cable of size 23/0.193 from ceiling rose to fan terminal conductor complete all as specified and as directed.
21
-
-
Material and labour for sub main wiring with two single runs of single core 6.0 sqmm PVC insulated unsheathed multistranded 1100 Volts grade with copper conductor drawn through and including non metallic PVC rigid conduit High grade ISI marked and its accessories including one run of single core 4.0 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth contunity conductor alongwith the wiring and connected from DB to DB main board complete all as specified Note: Two run of 6Sqmm cable, one run of 4Sqmm cable and one run of conduit will be measured as one unit.
175
-
-
Taking down UG cable of any type and any size and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and directed.
250
-
-
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth in soft/loose soil and getting out for laying of cable and errection pipe etc complete all as specified and directed.
50
-
-
Returning, filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick, in excavted soil complete all as specified and directed.
25
-
-
Removal of surplus soil of distance not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point complete all as specified and directed..
23
-
-
Material and labour sand cushioning in trenches for cable protection with coarse sand laid dry in trenches with uniform thickness including consolidation complete all as directed Note : Punned thickness will be measured and paid.
14
-
-
Supplying and laying well brunt brick, locally available best quality (Sub class 'B' bricks) laid in trenches perpendicular to UG cable protections complete all as specified and directed
1800
-
-
Supplying, testing, commissioning and laying LT UG Cable of size 4 Core 35 Sqmm laid in trenches/floor/on wall/service connection PVC insulated, sheathing and armd 1100 volts grade with aluminium conductor including connection to the main switch/cut out MCB/MCCB with necessary lugs after cutting to required length complete all as specified and directed
250
-
-
Supply and fix GI tubing 40 mm dia, light grade in protection of cable at road crossing/hard standing/pole protection fixed with clam as per site requirement etc all as specified and directed.
Make :- Jindal/TATA/Prakash Surya/Swastik/Appolo/BST/Kalinga/Goodluck or equivalent
15
-
-
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron. Earth strip protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer In Charge.
2
-
-