Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 52,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_664913_2Bid Award Id
ViewTender No
8822/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and spreading fine river sand in trenches for cushioning of under ground cable/filling cable ducts all as directed by Engr-in-Charge at site Note : - Only punned thickness shall be measured for payment purpose
160
-
-
Supply and lay burnt brick sub class ‘B’ of standard size laid in trenches as protection to cables complete all as directed
15.8
-
-
Boring of holes under road, pavement, hard standing by trenchless technology technique for 40-80 mm dia pipe all as specified and as directed by Engineer-in-Charge.
24
-
-
Material and Labour for cutting existing Bitumeneous road/PCC of size 30cm x 30cm for laying of underground cable with pipe, where boring is not possible and including necessary earth work and refilling the same in layers well ramming including watering as required and matching with the existing surface with 150mm thick PCC 1:2:4 type B1 and curing the same with wet gunny bags and removing debris to a distance not less than 50m complete all as specified and directed.
12
-
-
M&L for GI pipe light grade of sizes 80mm bore, ISI marked with all fitting for cable protection, laid in trenches, under road or fixing on wall/pole/crossing nallah etc including taking down old unserviceable all as specified and as directed by Engineer-in-Charge.
18
-
-
All as per item No. 8.00 above but size 50mm bore complete all as specified and as directed.
36
-
-
All as per item No. 8.00 above but size 40mm bore complete all as specified and as directed
60
-
-
M&L for 40mm bore dia PVC Flexible suction hose pipe (light grade), laid in trenches, under coping, bend or fixing on wall/pole/crossing nallah etc , all as specified and as directed by Engineer-in-Charge.
30
-
-
Taking out old unserviceable LT UG cables of sizes 25 sqmm to 95 sqmm and removal from site complete all as directed by Engineer-in-Charge.
800
-
-
Taking down old unserviceable service cable/PVC wire, twin core of any size removal from site complete all as directed by Engineer-in-Charge.
400
-
-
Dismantling ACSR conductors from the disturbed span including jumper, removing the binding from insulator, of any size for LT OH Line/ structures, etc complete all specefied and as directed
4
-
-
Dismantling/taking down old unserviceable cross arms, bracings, support, clamp including nuts, bolts and washers complete all as specified and as directed
2
-
-
Dismantling insulators any type, any size complete all as specified and as directed
50
-
-
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured heavy duty confirming to relevant IS specifcations with aluminum conductor of size 95 sq mm 3.5 core complete all as specified and as directed.
300
-
-
All as per item No. 17 above but 50 sq mm 3.5 core complete all as specified and as directed
200
-
-
All as per item No. 17 above but 25 sq mm 3.5 core complete all as specified and as directed
350
-
-
All as per item No. 17 above but 16 sq mm 4.0 core complete all as specified and as directed
300
-
-
All as per item No. 17 above but 16 sq mm 2.0 core complete all as specified and as directed
500
-
-
All as per item No. 17 above but 10 sq mm 2.0 core complete all as specified and as directed
400
-
-
All as per item No. 17 above but 6 sq mm 2.0 core complete all as specified and as directed
400
-
-
M&L straight through joints (heat shrinkable type) cable joint kit including jointing materials for making joints of UG electric cable 1100 volt grade heavy duty with PVC/XLPE insulated aluminium conductor nominal cross sectional area 10/16 to 25 sqmm 3.5/4.0 core and testing complete all as specefied and as directed.
3
-
-
M&L straight through joints (heat shrinkable type) cable joint kit including jointing materials for making joints of UG electric cable 1100 volt grade heavy duty with PVC/XLPE insulated aluminium conductor nominal cross sectional area 50 to 95 sqmm 3.5 core and testing complete all as specefied and as directed.
3
-
-
Demolition & dismantling Cement concrete plateform on floor of any description and in any position not otherwise specifically complete all as specified and directed by Engr- in- charge.
2
-
-
M&L for plain cement concrete type C1 (1:3:6) using 20 mm graded stone aggregate as in coping of pole/ any floor/path including necessary form work and finishing exposed surface/white washing all as directed.
2
-
-
Supply and fixing thermo plastic cable terminal box of size not less then 167x125x82mm with Cable Gland /terminals with locking arrangments including necessary mounting arrangement of any steel tubular/RCC poles with suitable size of clamps nuts bolts washer etc. fixed with poles including one single pole MCB of capacity 6-32A and PVC connector for cable termination complete all as specified and directed.
20
-
-
Supply & fixing wheather proof copper three core cable of size 1.5 Sqmm drawn in and including UPVC conduit medium grade fixed to pole/wall with suitable size clamps or fixing accessories complete all as specified and directed.
100
-
-
Supply & fixing street light bracket decorative type single arm fixing on top of the pole, made of GI pipe light grade pipe size not less than 1.0 Mtr, 32 mm dia as per sample and fixed with suitable size of MS clamps, nut, bolt, washers, welding work as required etc to poles/walls including taking down old unserviceable complete all as directed.
24
-
-
S&F Bus bar chamber / LT distribution board outdoor top canopy type, made out of 3.15 mm thick CRCA sheet weather/vermin proof, front door open type, 3 phase 4 wire, 440 volts , AC, 50Hz, with TPN aluminium bus bar of capacity 200 Amps rated with PVC insulated colour code sleves, mounted on porceclain insulators, complete with R-Y-B indicating lamps, duly wired including locking arrangement , cable gland for incoming and outgoing cables of suitable sizes, panel size not less than 600mm x 600mm x 450mm, mounting MS angle base frame duly painted with synthetic enamel black paint and totally mounted on PCC(1:3:6) foundation upto a height of 45 cm above ground level complete all as specified and directed
3
-
-
M & L for fabrication of LT feeder pillar box, out door type, double door, tent roof, factory made totally enclosed, dust and vermin proof, double leaf shutter in front and rear side made out of 3.15 mm thick CRCA sheet of size not less then 900mm x 900mm x 450mm and mounted on MS angle 50 mm X 50 mm X 6 mm suitable for 3 Phase, 415 volts, AC supply, 50 Hz, aluminium bus bar with colour sleeve, mounted on insulator with opening door both side with rubber bedding, locking arrangement and painting locking arrangement and painted to both internal and external surfaces with powder coating paint in heat process in grey colour complete all as specified and as directed and comprising the followings:-
BUSBAR :-
Aluminium bus bar for 4 Pole of minimum capacity 300 Amps- 01 (set of 04)
INCOMING :-
(a) MCCB, 4P, 160 Amps, 25 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 Nos
(b) LED R-Y-B indicating lamps (Set of Three)- 01 set
OUTGOING:-
(a) MCCB, 3P, 63 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 03Nos
(b) MCB 40-63 Amp SPN 10 KA 'C' series, 230 volts, AC, 50 Hz- 6 Nos
NOTE:- (i) Wiring of panel board with copper wire of suitable size and gauge with connector, copper lugs all as required at site.
(ii) The rate quoted by tenderer also includes to fix the legs of the panel box in PCC 1:3:6 pot hole foundation 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete.
1
-
-
Supply & fix Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated bus bar 240 Volts 4 way (2 + 2 way) single pole and neutral link including taking down old unserviceable one complete all as specified and directed.
10
-
-
S&F MCB 40 to 63 Amp SP&N, 240 volts 10 KA 'C' series including taking down old unserviceable one complete all as specified and directed.
5
-
-
S&F MCB 40 to 63 Amp TP&N, 415 volts 10 KA 'C' series including taking down old unserviceable one complete all as specified and directed.
5
-
-
S&F (in replacement) On load change over switch 160 Amps, 415V, AC 50 Hz, front operated handle, totally enclosed in sheet metal enclosure including fixing on wall with suitable accessories and connecting the cable end with suitable size lugs, nuts/bolts/washers etc complete all as specified and directed.
1
-
-
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
5
-
-
Overhauling and servicing of split type AC of capacity 1.5/2.0 TR of any make at different locations at Mil Stn Lekhapani, testing the unit complete with the following tasks :- (a) Overhauling & servicing.
(b) Inspection opening washing the condensor coil and cooling coil with chemical followed with pressurized water jet complete. (c) Inspection and treatment of leakage of refrigerant in the system. (d) Checking of operation of blower motor, condesnor motor and swing motor for noise free operations. (e) Oiling of condensor / blower motors and checking the earth continuity. (f) Inspection of all electrical parts / connections and rectification of any small defect. (g) Checking of functional of electronic remote control unit /PCB to ensure satisfactory functioning of indoor/outdoor unit complete. (h) Inspection and treatment of leakage water from indoor unit.
(j) Replacing minor spares (ie groomet rubber/rubber lining/washers/nuts&bolt) as required Note:- During servicing of unit, if any major spares / parts are required to be replaced it shall be measured and paid separately under respective items mentioned here- in - after as per direction.
15
-
-
All as per item 38.00 above but for Window type AC of capacity 1.5 / 2.0 TR. complete all as specified and as directed
10
-
-
S&F in replacement blower motor for Indoor unit of same specification/make as per existing one, suitable for all type split type AC 1.5/2.0 TR capacity complete including taking out of old unserviceable one all as directed.
2
-
-
S&F in replacement blower fan for indoor unit, of same specification/make as per existing one suitable for all type split type AC 2.0/1.5 TR capacity complete including taking out of old unserviceable one all as directed.
2
-
-
S&F in replacement blower fan with blower motor suitable for window type AC, of same specification/make as per existing one suitable for all type window type AC 2.0/1.5 TR capacity complete including taking out of old unserviceable one all as directed.
1
-
-
S&F in replacement condensor fan motor with blade for outdoor unit, of same specification/make as per existing one, suitable for all type split/window type AC 1.5/2.0TR capacity complete including taking out of old unserviceable one all as directed.
3
-
-
S&F in replacement hermitically type sealed, scroll or reciprocating , variable/ fixed speed compressor for all type split/window AC of capacity 1.5/2.0 TR as per existing including brazing work, laying of extra copper tubing, pressure testing, dehydration, gas charging upto required level and testing on full load for satisfactory functioning complete all as specified and directed by Engineer-in-charge Make : Copeland/Danfoss/kirloskar/ suitable for LG/Carrier/Blue star/Voltas/Hitachi/As per site requirement
3
-
-
M&L for rewinding of condensor fan motor of all split/window type AC of cap 1.5/2.0 TR including replacement of gun metal bushes, testing for noise free operation and refixing at its existing location complete all as specified and as directed by Engineer-in-charge
3
-
-
S&F in replacement Oscilation motor with swing blade strip suitable for indoor unit of 1.5 TR/2 TR capacity all type Air conditioners of same specification/make as per existing one complete including taking out the old unserviceable one all as directed
2
-
-
S&F in replacement complete PCB with Remote control unit for invertor/non invertor type split/window AC of cap 1.5 TR/2.0 TR, microprocessor based with transmission and receiving unit, cord less with features of digital display, mode selection, timer, temperature control or as per exsting specification and model complete all as specified and directed Make : Suitable for Blue Star / LG / Carrier/ Voltas/Hitachi/Samsung ACs
6
-
-
Dismantling and taking out voltage stablizer transformer unit, capacity 3 KVA to 5 KVA, any type, any specification, repair/replacement electric circuit board, all cable connections, complete overhauling of the system including repairing/replacement of push on switch, transistor, capacitor, relay transistor, diode, condenser, zener, pre-set, IC, 12 volt transformer, 24 Volt transformer, voltmeter, PVC connector, indicator lamp, cutout, MCB/fuse, and any other parts as required for proper functioning of stabilizer complete alongwith testing, commissioning including transportation from site to workshop and back all as directed by the Engr-in-Charge
10
-
-
S&F in replacement copper tubing flexible of dia 5/8" including heavy duty nitrile rubber insulation complete all as specified and directed by Engineer-in-charge
10
-
-
All as per item 49.00 but of dia 3/8" complete all as specified and as directed
10
-
-
All as per item 49.00 but of dia 1/2" complete all as specified and as directed
10
-
-
All as per item 49.00 but of dia 1/4" complete all as specified and as directed
10
-
-
S&F in replacement of flexible type water drain out pipe suitable for indoor unit tray with extra PVC pipe for out side of split AC as per existing type/model complete all as specified and directed.
5
-
-
Overhauling & servicing of water cooler any capacity by carrying out the following works at different location complete with the following tasks, all as specified and directed by Engineer-in-charge.
(a) Inspection, taking down opening & dismantling descaling brushing cleaning of storage tanks (b) Examine water tightness of stotage tank after cleaning (c) Carry out operations of stop cock, push cock, float valve etc (d) Replace washer & glands of all taps to ensure water tightness (e) Inspect over flow and remove blockage obstruction if any (f) Inspection and treatment of leakage of refrigerant in the system. (g) Check thermostate, Relay capacitor,fan motor, compressor and test its functioning (h) Inspect drain pipe and remove blockage if any (j) Check & correct all electrical wiring and its functioning (k) Testing of water coolers after repairs for satisfactory functioning complete (l) Replacing minor spares (ie groomet rubber/rubber lining/washers/nuts&bolt) as required Note :- During servicing of unit, if any major spares / parts are required to be replaced it shall be measured and paid separately under respective items mentioned here- in - after as per direction.
15
-
-
Overhauling & servicing of Refrigerator/Deep Freezer any capacity and make by carrying out the following works at different location of different establishment complete all as specified and directed by Engineer-in-charge (a) Inspection, taking down opening & dismantling, brushing washing cleaning of refrigerator (b) Check and correct earth continuity and all electrical wiring and its functioning complete
(c) Check thermostate, Relay capacitor,fan motor, compressor and test its functioning (d) Rectification of minor defects
(e) Inspection and treatment of leakage of refrigerant in the system.
(k) Testing after any repairs for satisfactory functioning complete (l) Replacing minor spares (ie groomet rubber/rubber lining/washers/nuts&bolt) as required Note :- During servicing of unit, if any major spares / parts are required to be replaced it shall be measured and paid separately under respective items mentioned here- in - after as per direction.
20
-
-
M&L for disconnecting the unserviceable sealed compressor unit from the Water Cooler (capacity 20/40 Ltrs) of any make & model and S&F new hermetically sealed compressor unit, of existing specification, including brazing work, laying of extra copper tubing, pressure testing, dehydration, gas charging upto required level, connecting it with both refrigerant line & electrical line for smooth operation on single phase 230 Volts, 50HZ AC supply and testing on full load for satisfactory functioning all as specified and as directed.
1
-
-
All as per Item No 56.00 above but capacity 40/80Ltrs complete all as specified and as directed
1
-
-
All as per Item No 56.00 above but capacity 60/120Ltrs complete all as specified and as directed
1
-
-
M&L for disconnecting the unserviceable sealed compressor unit from the Refrigerator (capacity 165 to 260 Ltrs) of any make & model and removing the same and S&F new hermetically sealed compressor unit, of existing specification, including brazing work, laying of extra copper tubing, pressure testing, dehydration, gas charging upto required level, connecting it with both refrigerant line & electrical line for smooth operation on single phase 230 Volts, 50HZ AC supply and testing on full load for satisfactory functioning all as specified and as directed.
1
-
-
All as per Item No 59.00 above but capacity 280 to 315 Ltrs complete all as specified and as directed
1
-
-
All as per Item No 59.00 above but capacity 340 to 480Ltrs complete all as specified and as directed
1
-
-
M&L for disconnecting the unserviceable sealed compressor unit from the Deep Freezer (capacity upto 405 Ltrs) of any make & model and removing the same and S&F new hermetically sealed compressor unit, of existing specification, including brazing work, laying of extra copper tubing, pressure testing, dehydration, gas charging upto required level, connecting it with both refrigerant line & electrical line for smooth operation on single phase 230 Volts, 50HZ AC supply and testing on full load for satisfactory functioning all as specified and as directed.
2
-
-
Supply and topping up/ full charging of Refrigerent Gas (R-22/R-410/R-134A/as per unit specification) for any type any specification of Air conditioners, Water coolers, Refrigerators & Deep freezers as per standard practice after pressure testing with filling of nitrogen gas, flushing out the system free from any oil / grease etc. cheking for leakages if any in the refrigerent system making good the leaking parts with necessary brazing/welding, ensuring leak proof system and testing for satifactory performance at different locations complete all as specified and as directed. (Note:- Cost of any type Refrigerent Gas included in the quoted rate)
60
-
-
Taking down Geyser 25/50 ltrs capacity of any make/type after disconnecting existing water supply and electric connections by unscrewing/cutting of holding nut & bolts incl opening of top & bottom cover, taking out complete internal assembly including geyser inner tank, inlet/outlet assembly, heating element, thermostat etc and descaling the geysers inner tank by chemical, cleaning and washing complete and re-assembling the same including connecting to electric and water supply system and including providing and grouting new nut bolts where required and testing of geyser for leakage and its proper functioning complete all as directed. (Note :- Defects developed during taking down geysers such as breaking of threads of pipe / geysers and GI fittings etc shall be rectified / replaced by the contractor at his own cost)
50
-
-
Fixing only geyser of 25/50 capacity, fixed on wall including supply & grouting of bolts in wall of suitable size with nuts & washers with necessary PCC work and making good the disturbed surfaces and matching with the existing surface complete all as specified & directed
10
-
-
Supply and replacing Heating element push/thread type or triangle/round base or any type with rubber gasket as per sample complete of capacity 2 KW, ISI marked suitable for 25/50 ltr cap of geyser of any make complete all as specified & directed
30
-
-
Supply and replacing capillary type thermostat suitable for 25/50 ltr geyser capacity with controller and connecting copper wires as required, suitable to adjust water temperature 20 degree C to 80 degree C, ISI marked complete all as specified & directed.
20
-
-
Supply and replacing Electronic capillary Thermal Switch, temperature adjustable type suitable for 25/50 ltr geyser complete all as specified & directed
10
-
-
Supply and replacing rigid PVC connection, heavy duty, 600mm long with CP brass adopter and washers at both ends suitable for hot water for 15mm dia pipe complete all as specified & directed
20
-
-
M&L for repair to defective/leaking geyser inner tank of any cap by gas welding / brass brazing etc at leaking spots and testing for leak proof repair all as specified & directed
6
-
-
Supply and replacing 3 pin metal plug top 15/20 amp for metal socket round type, as per existing complete all as specified & directed
10
-
-
S&F in replacement the following spare parts for Air conditioners, Water coolers,Refrigerators and Deep freezers of any make & model all as specified and directed. (a) Thermostate switch / Overload protector suitrable for water cooler/ Refrigerator/Deepfreezer
4
-
-
All as per item No 72.00 but Starting relay kit suitrable for water cooler/ Refrigerator/Deepfreezer complete all as specified and as directed
4
-
-
All as per item No 72.00 Connector open type 30 Amps, 3/4 way for AC outdoor unit complete all as directed.
5
-
-
All as per item No 72.00 Running capacitor 2.5 to 6 mfd heavy duty 230v, AC supply complete all as directed.
Make-Epcos / Sarada / Usha / Tibcon
5
-
-
All as per item No 72.00 Running capacitor 30 / 36 mfd heavy duty 230v, AC supply complete all as directed.
Make-Epcos / Sarada / Usha / Tibcon
5
-
-
All as per item No 72.00 Running capacitor 45 mfd heavy duty 230v, AC supply complete all as directed.
Make-Epcos / Sarada / Usha / Tibcon
5
-
-
All as per item No 72.00 Running capacitor 52 + 4 mfd heavy duty 230v, AC supply complete all as directed.
Make-Epcos / Sarada / Usha / Tibcon
5
-
-
All as per item No 72.00 Running capacitor 55 mfd heavy duty 230v, AC supply complete all as directed.
Make-Epcos / Sarada / Usha / Tibcon
5
-
-
All as per item No 72.00 Condensor motor of 1/16 or 1/32 or 1/40 HP including blade complete with clamps & bolts for suitrable for water cooler/ Refrigerator/Deepfreezer as per existing same complete all as directed.
3
-
-
All as per item No 72.00 Hose pipe size 20mm dia heavy duty with connectors ISI marked for water cooler complete all as directed.
6
-
-
All as per item No 72.00 PVC float valve (mini) 15mm dia with assembly for water cooler complete all as directed.
6
-
-
All as per item No 72.00 15 mm bore push cock brass body chromium plated for water cooler complete all as directed.
6
-
-
All as per item No 72.00 Shelf tray set complete including vegitable drawer with glass lid suitable for any type/capacity of Refrigerator
2
-
-
All as per item No 72.00 Door lock with key suitable for any type/capacity of Refrigerator/deep freezer/water cooler complete all as directed.
2
-
-
All as per item No 72.00 Door rubber gasket with magnetic strip for any type/capacity of Refrigerator complete all as directed.
2
-
-
All as per item No 72.00 Bulb with holder as per existing for refrigerator/Deep freezor complete all as directed.
5
-
-
All as per item No 72.00 Filter strainer/drier as per existing same for refrigerator/Deep freezor/watercoolers/window AC complete all as directed.
5
-
-
All as per item No 72.00 Evaporator cooling coil as per existing set for refrigerator/Deep freezor/watercoolers complete all as directed.
2
-
-
All as per item No 72.00 PVC insulated 3 core round flexible copper cable 1100 v grade of size 2.5 sq mm complete all as directed.
50
-
-
All as per item No 72.00 PVC insulated 4 core round flexible copper cable 1100 v grade of size 2.5 sq mm complete all as directed.
50
-
-
All as per item No 72.00 PCB with control unit complete for Refrigerator of any capacity, including features of digital display as per exsting specification and model complete all as directed.
1
-
-
All as per item No 72.00 cooling chamber/freezer with cover complete for Refrigerator of any capacity complete all as directed.
Note:- (for item sl No 72.00 to 93.00)
(i) Contractor will provide well experienced 1 No AC/Ref Mech/Elect with Helper for attending complaint/above works on emergengy basis (within 2-4 Hrs) rectifying the defects and making machine satisfactory functional, in addition to man power required for execution of other routine works.
(iii) All Tools & Plants required for repair work shall be provided/arranged by the contractor at his own arrangement to trade men & helpers.