Military Engineer Services Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 88,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_690405_1Tender No
8224/GE/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Dismantling cross arms of mild steel channel or angle sections etc. including removing unserviceable materials from site(s), complete all as directed.
6
-
-
... More
Material and labour for, cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including two coats of aluminium paint over a coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and directed.
6
-
-
... More
Dismantling of ACSR or AAC conductor from poles of any size and capacity and removing unserviceable materials from site(s), complete all as specified and directed.
6
-
-
... More
Material and labour for, aluminium conductor steel reinforced (ACSR) of size as per existing for making connection at transformer, LAs, CT , PT, GODs & drop out fuses etc complete all as specified and directed.
6
-
-
... More
Material and labour for, stay assembly having stay rod dia 20mm complete with all accessories such as mild steel galvanized flat iron stay clamp, all as shown in electrical plate No.1 of SSR Part-I, complete all as specified and directed.
Note : Excavation, earthwork and cement concrete work shall be measured and paid separately under relevant items of this schedule.
6
-
-
... More
Material and labour for, loop type insulator, vitreous porcelain, white, brown or green for stay assembly, with overall dimensions 90mmx140mm, clearance of hole 25.5mm, complete all as specified and directed.
6
-
-
... More
Material and labour for, galvanised stay strand, 7/4mm, complete all as specified and directed.
1.2
-
-
... More
Material and labour in replacement for danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white in 11000 volts, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size, complete all as specified and directed.
55
-
-
... More
Material and labour in replacement for switches air break switch, gang operated, triple pole, 11000 volts grade and current rating up to 400 Amps, mechanically operated, mounted on insulator of size 150 mm dia and 150 mm height and steel frame with operating mechanism worked from ground level having 3 Nos 11KV post insulators per phase with locking arrangements etc. and equipment shall be confirming to IS 9921 (Part I to V) including necessary electrical connections after taking down the old unserviceable GOD switches with all parts complete all as specified and directed.
8
-
-
... More
Material and labour in replacement for HT drop out expulsion fuse unit suitable for 100 Amps capacity at 11 KV, single pole (two post insulators per pole) with HT barrel fuse with holder including necessary connection to ACSR conductor of suitable size after taking down the old unserviceable drop out switches, complete all as specified and directed.
15
-
-
... More
Material and labour for, two coats of aluminium paint over a coat of red oxide zinc chrome primer including preparation of surfaces by spray painting external surfaces of steel tubular poles (HT/LT) with approved colour code, complete all as specified and directed.
45
-
-
... More
Material and labour for, two coats of weather coat over coat of including preparation of surfaces by spray painting external surfaces of PCC poles (HT/LT) at various Sub stations with approved colour code complete all as specified and directed.
55
-
-
... More
Taking up carefully defective HT UG cable of cross sectional area 95/120 Sqmm, 3 core from existing HT pole/ HT panels/ trenches/ along wall/ pipes/ across drain/ roof etc. after disconnecting elect supply from both end complete all as specified and directed.
520
-
-
... More
Laying only/ re-rooting of old taking down HT underground cable from trenches/ pole etc. aluminium conductor of cross sectional area 95/120 sqmm, 3 core complete all as directed.
300
-
-
... More
Laying only PCC cable cover for HT UG cable, of any description, complete all as directed.
278
-
-
... More
Laying only bricks cover for HT UG cable of any description, complete all as directed.
869
-
-
... More
Supply, laying, jointing, commissioning and testing HT UG cable of size 95 sqmm, 3 core, 11000 volts (earthed), aluminium conductor, XLPE insulated, earthed, screened, PVC bedded, armoured heavy duty electric cable conforming to IS-7098 (Part -II) 1985 with latest amendments drawn through pipe or laid in trenches, fixed on poles etc., complete all as specified and directed.
220
-
-
... More
Material and labour in replacement of lightening arresters set ( Set of 03 nos), non linear 12 KV, metal oxide type, distribution class 5 KA rupturing capacity for outdoor use with conforming to IS : 15086 PT- I of 2001, complete and suitable for 11KV supply system including taking down the old unserviceable ones, complete all as specified and as directed.
6
-
-
... More
Supply, jointing and testing in replacement of HT cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm including taking down old unserviceable jointing kit, complete all as specified and directed.
7
-
-
... More
Supply, jointing and testing in replacement of HT cable end jointing kit for 11000 volt grade cable cold shrinkable outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable (Earthed) of size 95 sqmm including taking down old unserviceable ones, complete all as specified and directed.
9
-
-
... More
Supply, jointing and testing in replacement of HT cable end jointing kit for 11000 volt grade cable cold shrinkable indoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable (Earthed) of size 95 sqmm including taking down old unserviceable jointing kit, complete all as specified and directed.
9
-
-
... More
Supply and laying in replacement of synthetic rubber insulated mats 2.5 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, complete all as specified and directed.
7
-
-
... More
Supplying and laying in replacement of synthetic Rubber insulated mats 3 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m
7
-
-
... More
Excavation in trenches, not exc. 1.5 m wide and not exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, taking out and laying of cables, laying water tubing, poles, struts/ stay etc. n exc 10 sqm on plan and not exc. 1.5 m in depth and getting out in soft/ loose soil, complete all as specified and directed.
174
-
-
... More
Returning filling in soft/ loose soil, including spreading, levelling, watering and well ramming in layers not exc. 25 cm, complete all as specified and directed.
121
-
-
... More
Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level not exc. 1.5 m above the starting point, complete all as specified and directed.
53
-
-
... More
Supply and laying of reinforced precast concrete cable cover, class EHV, type 1 with peak, size 450mm x 230mm x 50mm, laid flat across the axis of cable, abutting each other with gaps between adjacent cover not exceeding 10mm complete all as specified and directed.
1000
-
-
... More
Material and labour for, sand cushioning (dry) in trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed.
(NOTE : For the purpose of payment, punned thickness of sand cushioning only shall be measured and paid for).
35
-
-
... More
Material and labour for boring/ drilling by machines/ manual horizontally under the road in any type of soil without cutting/ disturbing the existing road and inserting GI pipe of any size for drawing the cable, complete all as specified and directed. Note:GI pipe shall be measured and paid separately under relevant item.
20
-
-
... More
Material and labour for cutting the road/ hard standing to a depth not exc.30 cm and depth not exc.75 cm for laying/ removal of HT/ LT UG cable or cable protection pipe of any size including making good the disturbed surfaces by using PCC(1:2:4) type B2 (using 40 mm graded crushed stone aggregate) for 100 mm thick on top including fair finishing, complete all as specified and directed.
10
-
-
... More
Supply and fix in replacement of 40 mm dia GI pipe ‘light grade’ with all fittings for protection of cable laid on road crossing, drain crossing, laid in floor or fixed to iron structures/ poles, complete all as specified and directed.
10
-
-
... More
Supply and fix in replacement of 50 mm dia GI pipe ‘light grade’ with all fittings for protection of cable laid on road crossing, drain crossing, laid in floor or fixed to iron structures/ poles, complete all as specified and directed.
10
-
-
... More
Supply and fix in replacement of 80 mm dia GI pipe ‘light grade’ with all fittings for protection of cable laid on road crossing, drain crossing, laid in floor or fixed to iron structures/ poles, complete all as specified and directed.
10
-
-
... More
Supply and fix in replacement for 100 mm dia GI pipe ‘light grade’ with all fittings for protection of cable laid on road crossing, drain crossing, laid in floor or fixed to iron structures/ poles, complete all as specified and directed.
10
-
-
... More
Material and labour for, earthing complete with copper earth plate electrode 600mm x 600mm x 3.15mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.50 metre below normal ground level connected to galvanised steel earth strip 20x3mm by means of bolts, nuts, check nuts and washers of galvanised steel and connected to main switch board or main control board as directed and including provision of concrete earth pit in PCC (1:3:6) type C1, 50mm thick pre-cast RCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) cover slab (Reinforced with 8mm dia TMT bar @15cm centre to centre bothways and suitable handle made of 10mm dia), provision of funnel, wire mesh, 20mm bore galvanised steel tubing (medium grade) for watering, charcoal or coke and salt in alternate layers of 15cm (compacted thickness), 40mm bore galvanised steel tubing (light grade) for protection of earth lead connection, necessary excavation and earth work in any type of soil complete all as specified and indicated on electrical plate No.3 of SSR Part-I (2009) including testing on completion, complete all as specified and directed.
5
-
-
... More
Material and labour for, earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.50 metre below normal ground level connected to galvanised steel earth strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised steel and connected to main switch board or main control board as directed and including provision of concrete earth pit in PCC (1:3:6) type C1, 50mm thick pre-cast RCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) cover slab (Reinforced with 8mm dia TMT bar @15cm centre to centre bothways and suitable handle made of 10mm dia), provision of funnel, wire mesh, 20mm bore galvanised steel tubing (medium grade) for watering, charcoal or coke and salt in alternate layers of 15cm (compacted thickness), 40mm bore galvanised steel tubing (light grade) for protection of earth lead connection, necessary excavation and earth work in any type of soil complete all as specified and indicated on electrical plate No.3 of SSR Part-I (2009) including taking out the old unserviceable earthing materials and testing on completion, complete all as specified and directed.
5
-
-
... More
Supply and fix in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3mm copper strip, complete all as specified and directed.
35
-
-
... More
Supply and fix in replacement of galvanised iron strip of size 25 x 4 mm as earth continuity conductor or main earth lead fixed to wall on batten or recess or chases/roof of bldg or buried in groud or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc above ground, complete all as specified and directed.
40
-
-
... More
Supply and fix in replacement of galvanised iron strip of size 32 x 6 mm as earth continuity conductor or main earth lead fixed to wall on batten or recess or chases/ roof of bldg or buried in groud or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc above ground, complete all as specified and directed.
30
-
-
... More
Supply and fix in replacement of aluminium strip of size 25 x4 mm as earth continuity conductor or main earth lead fixed to wall on batten or recess or chases/roof of bldg or buried in groud or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc above ground all as specified.
22
-
-
... More
Material and labour for, 4 pole/ 2 pole structure of 11 KV Gang operated devices servicing, greezing, tightning of connections of conductors/ HT cables, nut bolt etc, insulators (pin/ disc) checking and cleaning the surfaces with CRC, alignment of triple gang with existing pins, jumpering, replacement of GI pipe for gang operations handle (medium garde ,appx lenght 06 metres) including clamps etc., complete all as specified and directed.
45
-
-
... More
Material and labour for, preparation of old painted steel or iron surfaces of transformer of 100 KVA to 315 KVA capacity by scrapping with steel wire brush/ emery paper etc and applying one coat of synthetic enamel paint smoke grey colour using spray painting machine complete including writing of SM No. , MES No. etc. with black synthetic enamel paint on white back ground, complete all as specified and directed.
Note:- Necessary shut down of power supply be obtained from Engineer-in-Charge before the work and supply shall be restored immediately on completion of work.
11
-
-
... More
Material and labour for, preparation of old painted steel or iron surfaces of transformer of 25 KVA to 75 KVA capacity by scrapping with steel wire brush/ emery paper etc and applying one coat of synthetic enamel paint smoke grey colour using spray painting machine complete including writing of SM No. , MES No. etc. with black synthetic enamel paint on white back ground, complete all as specified and directed.
Note:- Necessary shut down of power supply be obtained from Engineer-in-Charge before the work and supply shall be restored immediately on completion of work.
15
-
-
... More
Supply and fix in replacement for LT bush insulator as per existing size, shape and make for 100 to 300 KVA capacity transformer, complete all as specified and directed.
3
-
-
... More
Supply and fix in replacement for LT bush insulator as per existing size, shape and make for 25 to75 KVA capacity transformer, complete all as specified and directed.
3
-
-
... More
Supply and fix in replacement for LT brass/ copper stud as per existing size , shape and make for 100 to 300 KVA capacity transformer, complete all as specified and directed.
5
-
-
... More
Supply and fix in replacement for LT brass/ copper stud as per existing size, shape and make for 25 to 75 KVA capacity transformer, complete all as specified and directed.
5
-
-
... More
Supply and fix in replacement for gasket ( Set of four) for LT bushing as per existing size and shape for 100 to 300KVA capacity transformer, complete all as specified and directed.
5
-
-
... More
Supply and fix in replacement for gasket ( Set of four) for LT bushing as per existing size and shape for 25 to 75KVA capacity transformer, complete all as specified and directed.
5
-
-
... More
Supply and fix in replacement for top cover cork gasket set as per existing size and shape for 100 to 300 KVA capacity transformer, complete all as specified and directed.
5
-
-
... More
Supply and fix in replacement for top cover cork gasket set as per existing size and shape for 25 to 75 KVA capacity transformer, complete all as specified and directed.
5
-
-
... More
Supply and fix in replacement for HV bushing with brass terminal with nuts and washers and sheet gasket as per existing size and shape for 25 to 75 KVA capacity transformer, complete all as specified and directed.
5
-
-
... More
Supply and fix in replacement for HV bushing with brass terminal with nuts and washers and sheet gasket as per existing size and shape for 100 to 300 KVA capacity transformer, complete all as specified and directed.
12
-
-
... More
Supply and fixing in replacement for breather assembly including silica gel of required quantity for 11/0.433 KV transformer for up to 300 KVA capacity, complete all as specified and directed.
20
-
-
... More
Supply, filling and topping up new transformer oil conforming to IS-335 of 1993 for filling/ topping up oil of transformer up to desired level complete all as specified and directed. ( Dielectric strength of oil shall not be less than 40KV ) Make: GULF/ POWER OIL or equivalent as approved by GE.
1795
-
-
... More
Dehydration and filtration of existing transformer oil of transformer at different location in site with filtration machine and heating system to get Di-electric strength of oil 40KV/cm minimum without disturbing the power supply system complete all as specified and directed.
8900
-
-
... More
Material and labour for replacement for rewinding of HV / LV limb of transformer/ stabilizer of any capacity by dismantling and removing the burnt out copper winding cleaning of limb thoroughly and rewinding the same with supper enameled proper size copper DPC wire having class 'F' insulation as per existing size of the same gauge and turn with proper class of insulation impregnated & baking, assembling and testing complete suitable for HT coil of 11/.433 KV transformer complete all as specified and directed. (dry type/ oil type)
Note: Transportation to & fro to local/ company workshop is deemed to be included in the unit quoted rate.
984
-
-
... More
Material and labour for, cleaning of conservator oil tank of capacity 25 to 315 KVA transformers including refixing of rubber cork gasket as per existing size, complete all as specified and directed.
15
-
-
... More
Deployment of manpower and cable fault locator machine duly mounted on vehicle for detection of HT UG cable fault of any size & make by applying upto 15 KV supply to locate the fault and any necessary arrangements required, contractor should be provided. Note: Payment is only applicable if require of contractor is able to trace out the fault.
10
-
-
... More
Overhauling of up to 100 KVA capacity transformer/ isolation TR, 11 KV/ 433 volt, by disconnecting LT/ HT connections, cleaning complete for making it carbon free, checking for any loose bushings and making it rectified if found and reconnecting with LT/ HT connections, testing and commissioning on load complete all as specified and directed.
Note:-
(i) Filtration of transformer oil if required will be measured and paid separately under relevant.
(ii) Topping up with new transformer oil if required will be measured and paid separately under relevant item.
(iii) Any spare part and rewinding if found unserviceable will be measured and paid separately as supply and fix in repair.
15
-
-
... More
All as per serial item No.63 here-in-before but 160 to 315 KVA capacity transformer 11 KV/ 433 V.
11
-
-
... More
Supply and spreading 40 mm size graded stone aggregate on ground of sub station, average spreading levelling complete, all as specified and directed. Note: Measurement shall be carried out for neat finished area of work executed.
Note for all items:(a) One HS Electrician and one helper should be available for attending day to day complaints on all days including/ Sunday and holiday from 09.00 hrs to 15.00 hrs. (b) Individual should be in possession of all required tools for rectification of complaints. (c) Labour charges and cost of reqired tools is deemed to be included in the unit rate quoted. (d) Work shall be executed by the authorised service mechanic/ Electrician of manufacturer, after satisfactorily completion of servicing of HT transformer/ equipment if any fault occurs upto completion of contract period should be attended by concerned rep within stipulated time frame without any failure. Quoted rates is deemed to be included all such charges. (e) Item No.1 to 67, if any above HT equipment and connected items become breakdown, the contractor shall locate the problem/ fault at site within 12 hours on intimation by JE/ Engineer-in-Charge and ensure that the fault and rectified within 48 Hours, failing which an amount of Rs 200 /- per hour will be recovered as penal recovery from any payment due to contractor after expiry of 48 hours.)
40
-
-
... More
Cutting, trimming and prunning of trees/ tree branches/ creepers/ climbers of all around existing sub station area up to fencing/ boundry wall including cleaning the disturbed area beneath and removing the tree branches and debris from site and depositing complete all as directed.
60
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%