Indian Oil Corporation Limited Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Indian Oil Corporation Limited - IOCL Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Jun 2024
Closing Date15 Jul 2024
Tender Amount₹ 30,74,54,255 
Notes
Download

Costs

Summary

Design, Supply, Installation, Testing And Commissioning Of Electrical Equipments (ht /lt), Cabling, Lighting, Earthing Along With Associated Works

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of trivector meter as per state electricity approved make for tariff metering including enclosure for Trivector meter.

1

-

82500

... More
POWER TRANSFORMER & LIGHTING TRANSFORMER

-

-

-

... More
Design, Supply, installation, testing, commissioning, shop testing, packing, transportation, delivery at storage of 1600 kVA Transformer Oil Type copper winding: 1600 kVA (ONAN), 415V, 11/0.433 KV, Dyn11, Z =6.25%, OLTC +/- 10% @2. 5% tapping from SEB, including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, including connection of auxiliary circuits, including fixing of nuts and bolts etc., consisting of all accessories, mandatory spares, erection & commissioning spare and recommended spares for 2 years operation and maintenance, including all labour and materials along with weather proof double compression Ni plated brass cable glands and cable lugs for outgoing cables and all other accessories for Transformer, complete in all respects as specified in technical specification, data sheet & Overall SLD (P.020268-G-21098-E001) of this tender and directions of Engineer-in-Charge. The supply includes first fill of transformer oil and all consumables. Transformer shall be complete with minimum accessories as follows: Complete set of gaskets, Silica Gel Breather, set of valves, Buchholz relay, complete winding temperature indicating equipment (WTI), Oil Temperature Indicating equipment (OTI), Pressure relief device with trip contacts, bushing of each type, CTs of each type for 51G & 64R as per attached Electrical Overall SLD (P.020268-G-21098-E001) and Oil Level Gauge etc. as per specification. CTs shall be provided as per SLD. (INCLUSIVE OF HEAT RUN TEST ) (Location - Outdoor) Note: The civil / structural works required for power transformer foundation is excluded and shall be paid separtely under respective civil item.

1

-

5550000

... More
Design, Supply, installation, testing, commissioning, shop testing, packing, transportation, delivery at storage of 125 kVA, copper winding Cast resin Dry type transformer (Indoor), with 415Volt,50Hz input and 415 Volt output, along with Weather proof double compression Ni plated brass cable gland and cable lugs for all incoming and outgoing cables, insulation class H temperature class limited to class B, including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, including connection of auxiliary circuits, including fixing of nuts and bolts etc., consisting of all accessories, mandatory spares, erection & commissioning spare and recommended spares for 2 years operation and maintenance, including all labour and materials, complete in all respects as specified in technical specification, data sheet & Overall SLD (P.020268-G-21098-E001) of this tender and directions of Engineer-in-Charge . Transformer shall be complete with minimum accessories as follows: Complete set of gaskets, winding temperature indicating equipment (WTI), bushing of each type etc. as per Specification/Data sheet/SLD.( INCLUSIVE OF HEAT RUN TEST ) (Location - PMCC/Substation)

1

-

720000

... More
Design, Supply, installation, testing, commissioning, shop testing, packing, transportation, delivery at storage of 50 kVA, copper winding Cast resin Dry type transformer (Indoor), with 415Volt,50Hz input and 415 Volt output, along with Weather proof double compression Ni plated brass cable gland and cable lugs for all incoming and outgoing cables, insulation class H temperature class limited to class B, including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, including connection of auxiliary circuits, including fixing of nuts and bolts etc., consisting of all accessories, mandatory spares, erection & commissioning spare and recommended spares for 2 years operation and maintenance, including all labour and materials, complete in all respects as specified in technical specification, data sheet & Overall SLD (P.020268-G-21098-E001) of this tender and directions of Engineer-in-Charge . Transformer shall be complete with minimum accessories as follows: Complete set of gaskets, winding temperature indicating equipment (WTI), bushing of each type etc. as per Specification/Data sheet/SLD.( INCLUSIVE OF HEAT RUN TEST ) (Location - PMCC/Substation)

1

-

455000

... More
11 KV VCB PANEL

-

-

-

... More
Design, Supply, Installation of 11KV CT with higher rating 100/1A CT as per Overall SLD (P.020268-G-21098-E001) along with termination and associated works. Class PS CT-3 nos, Class 5P10 CT - 3 nos., Class 1.0 CT - 3 nos.) including testing & commissioning of existing 11KV VCB Panel including all labour and materials, as per attached specification of this tender and directions of Engineer-in-Charge. (Location - PMCC/Substation)

9

-

75000

... More
DIESEL GENERATOR (DG) SET

-

-

-

... More
Design, Engineering, Manufacturing, Assembly, Testing at shop, Packing, Supply, Delivery at site, installation,testing & commissioning of 750 kVA (prime rating),415V, 50HZ, 3 phase, Silent DG Sets with AMF Panel, common base frame, plates & supporting structure including Exciter, AVR, Engine Panel, Generator Control & Monitoring Panel, 1250 A ACB Breaker Panel (with two outgoings) as per Overall SLD (P.020268-G-21098-E001), Annunciator, Batteries, Battery Charger(FCBC), lube oil system, cooling system, Diesel oil system, Interconnection power & control cables, cable accessories (including weather proof double compression Ni plated brass cable glands and cable lugs), Relays, Meters, External Day Tank (fuel tank) 990 litre capacity or more as per technical specifications with magnetic level switch, Silencer, Acoustic enclosure, Exhaust System, elbows, stack with structure , Anti Vibration Mounting Pads, Pipe, first fill of lubricant & consumables such as coolant, fuel oil for testing by client at works & at site ,commissioning with performance guarantee test and all other items as per Tender Specification and with all auxiliaries and accessories as required for smooth running of the DG set . as per attached specifications,data sheet & SLD. Height of Stack shall be as per CPCB norms. Performance load test at site, Residential silencer, spark arrestor, complete stack, ladder, provision of testing for pollution, one number Lightning arrestor (1000mm long 20mm dia.). Aviation obstruction lamp ( 2 x 15 W LED ultrabright ( RED) colour ) for DG Set stack shall be in the scope of Bidder. NOTE : 1. The above ratings are at 50 degree ambient temperature. Derating to be considered by the vendor( if applicable). 2. Following items shall be paid seperately in respective items : a. Supply of LT Power cables from DG set to PCC (Refer attached SLD) and external earthing system for DG sets. b. Civil Works for stack foundations & supporting structural steel arrangement of Exhaust pipe shall be paid seperately.

1

-

11625000

... More
Supply & Installation of Exhaust Pipe of suitable size as recommended by OEM including Asbestos rope / glass wool insulation & cladding in Aluminium sheeting. Exhaust pipe (IS:1239/3589 schedule 20) of suitable size as per as per manufacturer's recommendations/CPCB/CEA. Glass wool insulation and cladding in Aluminium sheeting (insulated with minimum 50 mm thickness with 64kg/cum density of rock wool wrapped with 24/26 SWG aluminium sheet cladding) Note: The measurement shall be done for the stack length beyond the exhaust silencer.

80

-

19650

... More
Design, Supply, installation, testing, commissioning of manual change over switch of rating 1250 Amp for power connection from existing DG to new DG with operating mechanism, all accessories, auxiliaries etc. complete in all respects as specified in technical specification, data sheet & SLD

1

-

240000

... More
LV SWITCHBOARDS / DISTRIBUTION PANELS / DISTRIBUTION BOARD

-

-

-

... More
Design, Supply, Installation, testing & commissioning of sheet steel enclosed, floor mounted, compartmentalised, free standing switch-boards, including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of foundation base material frame & its fixing by welding on foundation insert plates or angles embedded in the foundation, (The base frame supply cost shall be included in steel fabrication, however, fixing cost shall be included in this item cost.), placing on foundation channel, aligning, plumbing,leveling, positioning,bus bar bolting between transportation sections, bolting / tack welding with foundation channels of various shipping section of panels including supply of GI bolts, nuts and washers etc., assembling of shipping sections, connection of inner panel busbars, checking of terminal connection for tightness and proper wiring, including all labour and materials, as per attached specification of this tender and directions of Engineer-in-Charge. Panel shall be with hinged doors, with neoprene gasket, 2 Nos earth terminal shall be provided at the Panel frame with extension link for earthing connections, with pad locking arrangement & along with Weather proof double compression Ni plated brass cable glands and lugs for all incoming and outgoing feeders. Incoming & outgoing feeders with ACB/MCCB, CTs/PTs, Relays/ Contactors, meters, space heaters, MFM, selector switches, indication lamps etc.as per applicable SLDs. The Panel will have IP-52 rating degree of protection or otherwise specified in respective item. Colour shade of final paint shall be RAL 7032 or as approved by IOCL. The item is inclusive of the stenciling/ lettering of the LT/HT Panel Boards/Control Panels/LDBs & PDBs/Motors etc. Suitable double compression glands to be supplied with all switchboards and panels.

-

-

-

... More
PCC - 2500A with I/C ACB - 2500A, 415V PCC : Design, Supply, Installation, testing & commissioning of CRCA sheet steel enclosed, floor mounted, free standing PMCC Switch Board, 415V, 50 Hz, 3 Ph, 4 Wire, 2500 Amp, 50kA for 1 sec. AL. bus bar including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including installation on foundations or steel structures, aligning, leveling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per attached specification and Single Line Diagram of PCC of this tender and directions of Engineer-in-Charge. (Location: Substation/PMCC)

1

-

3412500

... More
COMMON MCC - 1000A with two Incomers 415V PMCC : Design, Supply, Installation, testing & commissioning of double front Common MCC panel of rating 1000 Amp (Dual Incomer) CRCA sheet steel enclosed, floor mounted, free standing PMCC Switch Board, 415V, 50 Hz, 3 Ph, 4 Wire, 1000 Amp,50kA for 1 sec. AL. bus bar including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including installation on foundations or steel structures, aligning, leveling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per attached specification and Single Line Diagram of COMMON MCC of this tender and directions of Engineer-in-Charge. (Location: Substation/PMCC)

1

-

5950000

... More
CRITICAL MCC - 400A with two Incomers 415V ESB : Design, Supply, Installation, testing & commissioning of double front Critical MCC panel of rating 400 Amp (Dual Incomer) CRCA sheet steel enclosed, floor mounted, free standing Emergency Switch Board, 415V, 50 Hz, 3 Ph, 4 Wire, 400Amp, 50kA for 1 sec.. AL. bus bar including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including installation on foundations or steel structures, aligning, leveling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per attached specification and Single Line Diagram of CRITICAL MCC of this tender and directions of Engineer-in-Charge. (Location: Substation/PMCC)

1

-

2367500

... More
AUTOMATIC POWER FACTOR CORRECTION PANEL (APFC PANEL)-01 Design, Supply, Installation, testing & commissioning of CRCA sheet steel enclosed, floor mounted, free standing indoor APFC Panel 415 V,TPN 50 kA for 1.0sec, with detuned filter of 350 kVAR in steps of (2 X 100 kVAR, 2 X 50 kVAR, 2 X 20 kVAR & 1X 10 kVAR) with automatic correction of Power Factor. ACBs shall be darwout type with single front type indoor with operating mechanism, all accessories, auxiliaries and all other necessary components for smooth operation including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, including installation on foundations or steel structures, aligning, leveling, grouting, testing and calibration of relays and meters etc., including all labour and materials, etc complete in all respects as specified in technical specification, data sheet & SLD of APFC of this tender, and directions of Engineer-in-Charge (Location: Substation/PMCC)

1

-

1787500

... More
AUTOMATIC POWER FACTOR CORRECTION PANEL (APFC PANEL)-02 Design, Supply, Installation, testing & commissioning of CRCA sheet steel enclosed, floor mounted, free standing indoor APFC Panel 415 V,TPN 50 kA for 1.0sec, with detuned filter of 570 kVAR in steps of (3 X 100kVAR, 2 X 50 kVAR, 7 X 20 kVAR & 3 X 10 kVAR) with automatic correction of Power Factor. ACBs shall be drawout type with single front type indoor with operating mechanism, all accessories, auxiliaries and all other necessary components for smooth operation including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, including installation on foundations or steel structures, aligning, leveling, grouting, testing and calibration of relays and meters etc., including all labour and materials, etc complete in all respects as specified in technical specification, data sheet & SLD of APFC of this tender, and directions of Engineer-in-Charge (Location: Substation/PMCC)

1

-

2860500

... More
415V Fire Panel Design, Supply, installation, testing, commissioning of CRCA sheet steel enclosed, floor mounted, free standing PDB for Fire Water Pump House 415 V,TPN 35 kA for 1.0sec, single front, fixed type MCCBs, compartmentalized, Indoor, Floor Mounted Panel with Incomers and Outgoing feeders,Metering and protection, MCCBs, MFM, CTs, PTs,indication lamp, switches, including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, including installation on foundations or steel structures, aligning, leveling, grouting, testing and calibration of relays and meters etc. Panel shall be suitable for bottom cable entry, all accessories, auxiliaries etc. complete in all respects as specified in technical specification, data sheet & SLD. The enclosure of this Panel shall have IP55 degree of protection. (Location: Fire Water Pump House)

1

-

2075000

... More
Jockey Pump Design, Supply, installation, testing and commissioning of Jockey pump controller along with pressure switch, annunciation panel as per specification including interconnection between the starter panels of Fire pumps/ Jockey pumps/ pressure switches and Annunciation panel for auto starting of the fire pumps/ jockey pumps as per the logic defined in the tender specification documents and UL Listed Jockey Pump Controllers as per NFPA 20; Entire interconnections shall be established using 2 C, 1.1 KV grade armoured copper cable of size 1.5 sqmm;The cable shall be laid at all places including clamping etc complete as required; The job shall be complete in all respects and specifications as per the logic and requirements to put the entire system in AUTO mode as per the specifications.Transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, including installation on foundations or steel structures, aligning, leveling, grouting, testing and calibration of controller, etc., including all labour and materials, as per attached specification of this tender and directions of Engineer-in-Charge.

2

-

262500

... More
MOV-DB / ROSOV-DB (Outdoor, FLP type): Design, Supply, Installation, testing & commissioning of CRCA sheet steel enclosed, floor/wall mounted FLP type MOV-DB , 415V, 50 Hz, 3 Ph, 4 Wire, 100 Amp, TPN, 35 kA for 1 sec. AL. bus bar, IP 65, outdoor, with Canopy of 14 gauge CRCA sheet, distribution board with incomer MCCB including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, including installation on foundations or steel structures, aligning, leveling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per attached specification and Single Line Diagram of this tender and directions of Engineer-in-Charge. I/C : 100A, 4P MCCB, Outgoing : 18nos. 16A TPN MPCB.

6

-

283750

... More
MOV-DB / ROSOV-DB (Outdoor, FLP type): Design, Supply, Installation, testing & commissioning of CRCA sheet steel enclosed, floor/wall mounted FLP type ROSOV-DB , 415V, 50 Hz, 3 Ph, 4 Wire, 100 Amp, TPN, 35 kA for 1 sec. AL. bus bar, IP 65, outdoor, with Canopy of 14 gauge CRCA sheet, distribution board with incomer MCCB including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, including installation on foundations or steel structures, aligning, leveling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per attached specification and Single Line Diagram of this tender and directions of Engineer-in-Charge. I/C : 100A, 4P MCCB , Outgoing : 12nos. 16A TPN MPCB.

2

-

262000

... More
MARSHALLING CABINET

-

-

-

... More
Design, Supply, installation, tseting & commissioning of wall mounted type Marshalling Cabinet (Interphassing cabinet) having 500 terminals suitable for 2.5 mm2 / 1.5 mm2 (Cu.) with required Nos. of non- FLP, Double Compression Cable Glands.

2

-

109250

... More
Design, Supply, installation, tseting & commissioning of floor mounted type Marshalling Cabinet (Interphassing cabinet) having 250 terminals suitable for 2.5 mm2 / 1.5 mm2 (Cu.) with required Nos. of non- FLP, Double Compression Cable Glands

1

-

80250

... More
LIGHTING DISTRIBUTION BOARDS

-

-

-

... More
Design, Supply, Installation, testing, and commissioning of 415V/240V lighting/power DB, Surface/Recess mounting type sheet steel enclosure of approved make having 4 Pole MCCB/MCB with current limiting 10 kA (LSIG)/RCCB/ELCB as incoming and SP/DP/TP MCB (10kA/16kA type) for out going circuit complete with wiring,indication lamp, ammeter etc including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, testing and calibration of relays and meters etc., all labour and materials as per specification, Single Line Diagram of this tender and the direction of Engineer-in-charge. The Panel will have IP-52 rating degree of protection or otherwise specified in respective item. Colour shade of final paint shall be RAL 7032 or as approved by IOCL. Note:Civil & structural works shall be paid under respective items.

-

-

-

... More
Main Lighting Distribution Board (MLDB): Design, Supply, Installation, testing & commissioning of CRCA sheet steel enclosed, floor mounted, free standing Lighting Board, 415V, 50 Hz, 3 Ph, 4 Wire, 250 Amp, 10kA for 1 sec. Cu. bus bar, single front, fixed type microprocessor based MCCBs, compartmentalized, Indoor, with Incomers and Outgoing feeders, Metering and protection, MCCBs (LSIG protection), distribution board with incomer,indicating lamps, main contactor & auxiliary contactors etc including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including installation on foundations or steel structures, aligning, leveling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per attached specification and Single Line Diagram of MLDB of this tender and directions of Engineer-in-Charge. Panel shall be suitable for bottom cable entry for incoming / outgoing feeders. along with Weather proof double compression Ni plated brass cable glands and lugs for all incoming and outgoing feeders (Location: Substation / PMCC) :

1

-

791250

... More
Emergency Main Lighting Distribution Board (EMLDB): Design, Supply, Installation, testing & commissioning of CRCA sheet steel enclosed, floor mounted, free standing Lighting Board, 415V, 50 Hz, 3 Ph, 4 Wire, 100 Amp, 10kA for 1 sec. Cu. bus bar, single front, fixed type microprocessor based MCCBs, compartmentalized, Indoor, with Incomers and Outgoing feeders, Metering and protection, MCCBs (with LSIG protection), distribution board with incomer, indicating lamps, main contactor & auxiliary contactors etc including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including installation on foundations or steel structures, aligning, leveling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per attached specification and Single Line Diagram of EMLDB of this tender and directions of Engineer-in-Charge. Panel shall be suitable for bottom cable entry for incoming / outgoing feeders. along with Weather proof double compression Ni plated brass cable glands and lugs for all incoming and outgoing feeders (Location: Substation / PMCC)

1

-

423508

... More
Flame Proof Indoor Lighting Distribution Board (ILDB): Design, Supply, Installation, Testing & Commissioning of 415V, 50 Hz, 3 Ph, 4 Wire, 32 A, 10 kA for 1 sec.Cu busbar, IP-65, Indoor Type, 'Ex-d' type suitable for Zone-2, Gas Group-IIA/ IIB/ IIC, Temperature Class-T3, Aluminium alloy (LM6) enclosure, wall or frame mounted, IP 65, Weatherproof with Canopy, Non-compartmentalised, Double door, Lighting Panels along with Flameproof proof double compression Ni plated brass cable glands and lugs suitable for bottom cable entry, incomer and outgoing feeders, with indication lamp, etc complete in all respect as per attached SLD, Specification, Data sheet of this tender. Incomer : 1 No. 32A, 4P MCCB/MCB Sub Incomer : 3 Nos. 25A, DP RCCB/ELCB (30mA sensitivity) Outgoing : 6 Nos. 16A, SPN MCBs

2

-

225750

... More
Weather Proof Indoor Lighting Distribution Board (ILDB): Design, Supply, Installation, Testing, & Commissioning of 415V, 50 Hz, 3 Ph, 4 Wire, 32A, 10 kA for 1 sec. Cu busbar, Indoor Type, Floor/Wall mounted weatherproof Lighting Panel IP55, CRCA sheet steel enclosure, wall or frame mounted, Non-compartmentalised, Double door, Weatherproof, along with Weatherproof double compression Ni plated brass cable glands and lugs and sheet steel canopy, suitable for bottom cable entry, incomer and outgoing feeders, with indication lamp, etc complete in all respect as per attached SLD , Specification, Data sheet of this tender. Incomer : 1 No. 32A, 4P MCCB/MCB Sub Incomer : 3 Nos. 16A, DP RCCB/ELCB (30mA sensitivity) Outgoing : 6 Nos. 16A, SPN MCBs

3

-

116960

... More
Weather Proof Oudoor Lighting Distribution Board (OLDB): Design, Supply, Installation, Testing, & Commissioning of 415V, 50 Hz, 3 Ph, 4 Wire, 63A, 10 kA for 1 sec. Cu busbar, Indoor Type, Floor/Wall mounted weatherproof Lighting Panel IP55, CRCA sheet steel enclosure, wall or frame mounted, Non-compartmentalised, Double door, Weatherproof, along with Weatherproof double compression Ni plated brass cable glands and lugs and sheet steel canopy, suitable for bottom cable entry, incomer and outgoing feeders, with indication lamp, etc complete in all respect as per attached SLD , Specification, Data sheet of this tender. Incomer : 1 No. 63A, 4P MCCB/MCB Sub Incomer : 3 Nos. 16A, DP RCCB/ELCB (30mA sensitivity) Outgoing : 12 Nos. 16A, SPN MCBs

3

-

142580

... More
Flame proof Outdoor Lighting Distribution Board (OLDB): Design, Supply, Installation, Testing & Commissioning of 415V, 50 Hz, 3 Ph, 4 Wire, 63 A, 10 kA for 1 sec. cu busbar, IP-65, Indoor Type, 'Ex-d' type suitable for Zone-2, Gas Group-IIA/ IIB/ IIC, Temperature Class-T3, Aluminium alloy (LM6) enclosure, wall or frame mounted, IP 65, Weatherproof with Canopy, Non-compartmentalised, Double door, Lighting Panels along with Flameproof proof double compression Ni plated brass cable glands and lugs suitable for bottom cable entry, incomer and outgoing feeders, with indication lamp, etc complete in all respect as per attached SLD, Specification, Data sheet of this tender. Incomer : 1 No. 63A, 4P MCCB/MCB Sub Incomer : 3 Nos. 25A, DP RCCB/ELCB (30mA sensitivity) Outgoing : 12 Nos. 16A, SPN MCBs

3

-

252750

... More
Weatherproof Outdoor type Normal lighting panel: Design, Supply, Installation, Testing & Commissioning of 415V, 3Ph & N, 10kA 1 sec, with cu busbar, sheet steel enclosure, wall or frame mounted, IP 65 protected, Weatherproof with canopy, Non-compartmentalised, Double door, Lighting Panels along with Weather proof double compression Ni plated brass cable glands and lugs for all incoming and outgoing feeders, suitable for bottom cable entry complete in all respect as per attached SLD Specification/Data sheet Incomer : 100A 4P, MCCB Outgoings- 25A 4P MCB - 8 nos

1

-

167750

... More
Flameproof Outdoor type Normal lighting panel Design, Supply, Installation, Testing & Commissioning of 415V, 3Ph & N, 10kA 1 sec, with cu busbar Aluminium alloy (LM6) enclosure, flameproof Ex"d", IIA, IIB, T3, wall or frame mounted, IP 65, Weatherproof with Canopy, Non-compartmentalised, Double door, Lighting Panels along with Flameproof proof double compression Ni plated brass cable glands and lugs suitable for bottom cable entry complete in all respect as per attached SLD , Specification/Data sheet. Incomer : 100A 4P, MCCB Outgoings- 25A 4P MCB - 8 nos

1

-

194700

... More
Weatherproof Yard Lighting Distribution Board (YLDB): Design, Supply, Installation, testing & commissioning of CRCA sheet steel enclosed, wall mounted, indoor/outdoor YLDB , 415V, 50 Hz, 3 Ph, 4 Wire, 160Amp, TPN, 10kA for 1 sec. cu. bus bar, weatherproof IP 55 degree of protection, distribution board with incomer MCCB, wall or frame mounted, Non-compartmentalised, Double door, Weatherproof, along with Weatherproof double compression Ni plated brass cable glands and lugs and sheet steel canopy, suitable for bottom cable entry, incomer and outgoing feeders, with indication lamp, etc complete in all respect as per attached SLD, Specification, Data sheet of this tender. Incomer : 160A TPN, MCCB Outgoings- 63A 4P MCB - 6 nos, 32 A 4P MCB,- 3 nos

1

-

147450

... More
Flameproof Yard Lighting Distribution Board (YLDB): Design, Supply, Installation, testing & commissioning of CRCA sheet steel enclosed, wall mounted, indoor/outdoor YLDB , 415V, 50 Hz, 3 Ph, 4 Wire, 160Amp, TPN, 10kA for 1 sec. cu. bus bar, flameproof 'Ex-d' type suitable for Zone-2, Gas Group-IIA/ IIB/ IIC, Temperature Class-T3, Aluminium alloy (LM6) enclosure with canopy, wall or frame mounted, IP 65 degree of protection, distribution board with incomer MCCB, wall or frame mounted, Non-compartmentalised, Double door, Weatherproof, along with Weatherproof double compression Ni plated brass cable glands and lugs, suitable for bottom cable entry, incomer and outgoing feeders, with indication lamp, etc complete in all respect as per attached SLD, Specification, Data sheet of this tender. Incomer : 160A TPN, MCCB Outgoings- 63A 4P MCB - 6 nos, 32 A 4P MCB,- 3 nos

1

-

310500

... More
Design, Supply, Installation, connection, testing, and commissioning of 415V of indoor type Lighting Panel for security room consisting of 32 A TPN MCCB with ELCB as incomer with cu busbar and 3 nos of 10A SPN MCBs, 6 Nos of 6 A SPN MCB out goings complete with wiring etc including all labour and materials as per specification.

2

-

116500

... More
Design, Supply, Installation, connection, testing, and commissioning of 415V of indoor type emergency Lighting Panel for PMCC & Control room consisting of 32A TPN MCCB with cu busbar ELCB as incomer and 3 nos of 10A SPN MCBs, 6 Nos of 6 A SPN MCB out goings complete with wiring etc including all labour and materials as per specification.

2

-

113629

... More
Design, Supply, Installation, connection, testing, and commissioning of 415V of indoor type normal Lighting Panel for PMCC & Control room consisting of 32A TPN MCCB with cu busbar ELCB as incomer and 8 nos of 25A DP MCBs, out goings complete with wiring etc including all labour and materials as per specification.

2

-

113050

... More
110V DC system (Battery, Battery charger and DC DB)

-

-

-

... More
Design, Supply, Installation, testing and commissioning of 5 kVA 110V DC Battery Charger & DCDB System (IP-31) comprising 110V DC Battery Bank for 30 mins back-up, Chargers, Battery isolator/MCCB of suitable rating & DC Distribution Board etc. which includes installation of metal stands, placing of batteries on stands on cell insulators, fixing the cell, interconnecting the battery cells, cell booster and charging the battery cells as per attached specification of this tender .Suitable size of double compression glands shall be supplied with Battery Charger and DCDB. Vendor shall supply suitable battery of AH rating calculated as per duty cycle/load details attached with datasheet and submit the sizing calculation accordingly. Location: PMCC NOTE :Supervision of laying & termination of all inter-panel/ inter-cubicle cabling including cabling up to Battery Bank and inter-tier cabling of Battery Bank shall be in the scope of Supplier . However, supply, laying and termination of the cables shall be done by the contractor.

1

-

2506500

... More
DCDB : 110V DC, 63A, Cu bus bar, DC DB shall be indoor Type Incomer - 63A DC, DP MCCB Outgoing - 16 Nos. 16A DC, DP MCB

1

-

180500

... More
AC UPS System Design, Supply, Installation, testing & commissioning of following AC UPS system (IP-31) : 230 AC UPS in 2 x 100% parallel redundant configuration complete with battery bank (2 x 100%), Rectifier / Charger, Inverter, Main / maintenance bypass switch, battery and battery rack, AC Distribution board with requisite incoming and outgoing feeders for computer power supply. The battery backup duration shall be 60 Mins. The battery shall be VRLA. Scope includes transportation from store/yard to site at the place of installation, filling with electrolyte, aligning, leveling, grouting, assembly of battery racks, fixing of inter-cell connectors etc., including all labour and materials, as per attached specification of this tender and directions of Engineer-in-Charge.AC UPS and UPSDB shall be supplied along with Weatherproof double compression Nickel plated brass glands and lugs suitable for cable sizes . UPS. The item is inclusive of Heat Run Test. 2x 5 kVA, 3 Phase, 4 wire, 415V AC input, 240V AC output, parallel-redundant AC UPS (2 x 100% UPS module) with by- pass, Common VRLA battery (2 x 100% ) of 60 minutes back up time for each unit, AC UPS DB and all interconnecting cables.

1

-

1722500

... More
Local control station (LCS)

-

-

-

... More
Design, Supply, Installation, testing and commissioning of following Industrial type LCS, Weatherproof, Flameproof “Ex-d” (suitable for hazardous area of gas group IIA/IIB, temperature class T3 and Zone-2), IP 65, Local Control Station suitable for Wall / Column / Structure mounting. All LCS shall be made up of Aluminium alloy (LM6 grade) with Canopy of 14 gauge CRCA sheet with side cover. LCS shall confirm to attached specification/data sheet. LCS shall be supplied along with Flameproof Double compression, Ni plated brass cable glands & lugs as per attached specification of this tender.

-

-

-

... More
FLP (Zone-1, IIA/IIB, T3) IP65 Local control station provided with recess type START STOP PB, Suppressed scale Ammeter & 1 no. mushroom head stay put type emergency stop PB with Keys/lock & pin arrangement, Local remote switch (with additional contacts to give the status of Local remote switch to DCS/PLC) including flameproof double compression stainless steel cable glands & plugs, suitable for outdoor installation as required as per attached specifications of this tender.

7

-

18000

... More
Design, Supply, installation, testing and commissioning of following Industrial, weatherproof type LCS, IP-65, Local Control Station suitable for Wall / Column / Structure mounting. LCS shall be made up of sheet steel with Canopy of 14 gauge CRCA sheet with side cover. LCS shall confirm to attached specification/data sheet. LCS shall be supplied along with Double compression, Ni plated brass cable glands & lugs as per attached specification of this tender.

-

-

-

... More
Weatherproof, IP 65 LCS provided with 1 no. mushroom head stay put type emergency stop PB with Keys/lock & pin arrangement, 1 no. recess type PB for start, Local remote switch (with additional contacts to give the status of Local remote switch to DCS/PLC) & Suppressed scale Ammeter suitable for outdoor installation including double compression stainless steel cable glands & plugs, as required as per attached specifications of this tender.

5

-

10475

... More
Break glass type Emergency Trip Push Button (ETPB) for transformer: weather proof emergency stop push button(EPB) with ON-OFF LED indication break glass type enclosure, 3mm thick CRCA canopy, weatherproof double compression Nickel Plted Brass cable glands(2 nos.) and 1NO+1 NC contact.

1

-

9000

... More
JUNCTION BOX (JBs)

-

-

-

... More
JUNCTION BOXES FOR PUMP MOTOR (WEATHER PROOF, FLAME PROOF): Design, Supply, installation, testing & commissioning of following 415V, 3P, Industrial type, Weatherproof, Flame proof “Ex-d” (suitable for hazardous area of gas group IIA/IIB, temperature class T3 and Zone-2), IP 65 suitable for Wall / Column / Structure mounting Including cabling from JB to terminal box for Star-Delta pump motor having different terminal for star and delta connection. All JBs shall be made up of cast Aluminium alloy (LM6 grade) with Canopy of 14 gauge CRCA sheet with side cover. JBs shall confirm to attached specification/data sheet. Junction Boxes shall be complete with busbar of suitable rating, support insulator, suitable for tentative cable sizes as indicated below & shall be supplied along with FLP type double compression, Ni plated brass cable glands, lugs & plugs. However, exact cable sizes shall be indicated during drawing approval only. Please note that all cables shall be Aluminium conductor(10 sqmm & above)/Copper conductor(4 sqmm & below) (2 runs of Incoming cable size 3C x 400 sqmm /2 runs of Outgoing Cable shall be 3C x 95 sqmm, XLPE insulated, extruded PVC inner & outer sheathed, FRLS, Armoured cables.)

6

-

62200

... More
JUNCTION BOXES FOR PUMP MOTOR (WEATHER PROOF, FLAME PROOF): Design, Supply, installation, testing & commissioning of following 415V, 3P, Industrial type, Weatherproof, Flame proof “Ex-d” (suitable for hazardous area of gas group IIA/IIB, temperature class T3 and Zone-2), IP 65 suitable for Wall / Column / Structure mounting Including cabling from JB to terminal box for Star-Delta pump motor having different terminal for star and delta connection. All JBs shall be made up of cast Aluminium alloy (LM6 grade) with Canopy of 14 gauge CRCA sheet with side cover. JBs shall confirm to attached specification/data sheet. Junction Boxes shall be complete with busbar of suitabe rating, support insulator, suitable for tentative cable sizes as indicated below & shall be supplied along with FLP type double compression, Ni plated brass cable glands, lugs & plugs. However, exact cable sizes shall be indicated during drawing approval only. Please note that all cables shall be Aluminium conductor(10 sqmm & above)/Copper conductor(4 sqmm & below)(2 runs of Incoming cable size of upto 3C x 70 sqmm /2 runs of Outgoing Cable shall be 3C x 35 sqmm, XLPE insulated, extruded PVC inner & outer sheathed, FRLS, Armoured cables.)

6

-

41500

... More
JUNCTION BOXES FOR PUMP MOTOR (WEATHER PROOF, NON-FLAME PROOF): Design, Supply, installation, connection, testing & commissioning of following 415V, 3P, Industrial type, Weatherproof, IP 65 suitable for Wall / Column / Structure mounting Including cabling from JB to terminal box for Star-Delta pump motor having different terminal for star and delta connection. All JBs shall be made up of cast Aluminium alloy (LM6 grade) with Canopy of 14 gauge CRCA sheet with side cover. JBs shall confirm to attached specification/data sheet. Junction Boxes shall be complete with busbar of suitable rating, support insulator, suitable for tentative cable sizes as indicated below & shall be supplied along with Non FLP type double compression, Ni plated brass cable glands, lugs & plugs. However, exact cable sizes shall be indicated during drawing approval only. Please note that all cables shall be Aluminium conductor (2 runs of Incoming cable size 3C x 400 sqmm /2 runs of Outgoing Cable shall be 3C x 120 sqmm, XLPE insulated, extruded PVC inner & outer sheathed, FRLS, Armoured cables.)

3

-

38291

... More
JUNCTION BOXES FOR PUMP MOTOR (WEATHER PROOF, NON-FLAME PROOF): Design, Supply, installation, connection, testing & commissioning of following 415V, 3P, Industrial type, Weatherproof, IP 65 suitable for Wall / Column / Structure mounting Including cabling from JB to terminal box for Star-Delta pump motor having different terminal for star and delta connection. All JBs shall be made up of cast Aluminium alloy (LM6 grade) with Canopy of 14 gauge CRCA sheet with side cover. JBs shall confirm to attached specification/data sheet. Junction Boxes shall be complete with busbar of suitable rating, support insulator, suitable for tentative cable sizes as indicated below & shall be supplied along with Non FLP type double compression, Ni plated brass cable glands, lugs & plugs, PVC Shrouds. However, exact cable sizes shall be indicated during drawing approval only. Please note that all cables shall be Aluminium conductor (2 runs of Incoming cable size 3.5C x 70 sqmm /2 runs of Outgoing Cable shall be 3.5C x 35 sqmm, XLPE insulated, extruded PVC inner & outer sheathed, FRLS, Armoured cables.)

3

-

24250

... More
JUNCTION BOXES FOR LIGHTING FIXTURES (WEATHER PROOF, NON-FLAME PROOF): Design, Supply, installation, testing & commissioning of following 16A, 240V, 4-way, Ph-N, Industrial type, Weatherproof, IP 65 suitable for Wall / Column / Structure/ Pole mounting. Including wiring from JB to Fixture with terminals block with additional earthing terminals and end clamps etc. All JBs shall be made up of cast Aluminium alloy (LM6 grade). JBs shall confirm to attached specification/data sheet. Junction Boxes shall be suitable for cable sizes tentatively as indicated below & shall be supplied along with Double compression cable glands, Ni plated brass cable glands, lugs & plugs, PVC shrouds. However, exact cable sizes shall be indicated during drawing approval only. Please note that all cables shall be Aluminium conductor (10 sqmm & above) / Copper conductor (6 sqmm & below), XLPE insulated, extruded PVC inner & outer sheathed, FRLS, Armoured cables.

5

-

8550

... More
JUNCTION BOXES FOR LIGHTING FIXTURES (WEATHER PROOF, FLAME PROOF): Design, Supply, installation, testing & commissioning of following 16A, 240V, 4-way, Ph-N, Industrial type, Weatherproof, IP 65 suitable for Wall / Column / Structure/ Pole mounting. Including wiring from JB to Fixture with terminals block with additional earthing terminals and end clamps etc. All JBs shall be made up of cast Aluminium alloy (LM6 grade) Flameproof “Ex-d” (suitable for hazardous area of gas group IIA/IIB, temperature class T3 and Zone-2). JBs shall confirm to attached specification/data sheet. Junction Boxes shall be suitable for cable sizes tentatively as indicated below & shall be supplied along with Flameproof double compression, Ni plated brass cable glands, lugs & plugs, PVC Shrouds. However, exact cable sizes shall be indicated during drawing approval only. Please note that all cables shall be Aluminium conductor (10 sqmm & above) / Copper conductor (6 sqmm & below), XLPE insulated, extruded PVC inner & outer sheathed, FRLS, Armoured cables.

35

-

8250

... More
CANOPY FOR JBS/LCS/FIELD EQUIPMENTS. Design, Supply & Installation of of Sheet steel canopies made of 14 gauge CRCA sheet with side cover, PU painted to be provided as applicable for junction boxes, local control stations and others electrical equipment's located outdoor. Note: This items is applicable as per site requirement and direction of Engineering-in charge.

10

-

4187.5

... More
JUNCTION BOXES FOR POWER SOCKETS (WEATHER PROOF, FLAME PROOF): Design, Supply, Installation, Testing & Commissioning of following Industrial type, Weatherproof, IP 65 suitable for Wall / Column / Structure mounting JBs with terminals block with additional earthing terminals and end clamps etc. All JBs shall be made up of cast Aluminium alloy (LM6 grade) with Canopy of 14 gauge CRCA with side cover, Flameproof “Ex-d” (suitable for hazardous area of gas group IIA/IIB, temperature class T3 and Zone-2). JBs shall confirm to attached specification/data sheet. Junction Boxes shall be suitable for cable sizes tentatively as indicated below & shall be supplied along with Flameproof Double compression, Ni plated brass cable glands, lugs & plugs, PVC shrouds. However, exact cable sizes shall be indicated during drawing approval only. Please note that all cables shall be Aluminium conductor (10 sqmm & above) / Copper conductor (6 sqmm & below), XLPE insulated, extruded PVC inner & outer sheathed, FRLS, Armoured cables. Note: Civil & structural works shall be paid under respective items.

-

-

-

... More
16A, 415V,TPN, 6-way

3

-

22900

... More
16A, 230V, Ph-N, 6-way

3

-

17700

... More
JUNCTION BOXES FOR POWER SOCKETS (WEATHER PROOF, NON-FLAME PROOF): Design, Supply, Installation, Testing & Commissioning of following Industrial type, Weatherproof, IP 65 suitable for Wall / Column / Structure mounting JBs with terminals block with additional earthing terminals and end clamps etc. All JBs shall be made up of cast Aluminium alloy (LM6 grade) with Canopy of 14 gauge CRCA with side cover. JBs shall confirm to attached specification/data sheet. Junction Boxes shall be suitable for cable sizes tentatively as indicated below & shall be supplied along with Weatherproof Double compression, Ni plated brass cable glands, lugs & plugs. However, exact cable sizes shall be indicated during drawing approval only. Please note that all cables shall be Aluminium conductor (10 sqmm & above) / Copper conductor (6 sqmm & below), XLPE insulated, extruded PVC inner & outer sheathed, FRLS, Armoured cables. Note: Civil & structural works shall be paid under respective items.

-

-

-

... More
16A, 415V,TPN, 6-way

3

-

12000

... More
16A, 230V, Ph-N, 6-way

3

-

7575

... More
INDUSTRIAL POWER SOCKET OUTLETS WITH INTEGRAL PLUG TOPS (WEATHERPROOF, FLAMEPROOF TYPE): Design, Supply, Installation, Testing & Commissioning of Power Socket outlets shall be Flame proof “Ex-d” (suitable for hazardous area of gas group IIA/IIB, temperature class T3 and Zone-2), Industrial type, (IP 65) interlocked with MCB and ELCB and suitable for loop-in loop-out entries for armoured cable as specified, enclosed with Cast Aluminium alloy (LM-6 grade), with stainless steel hardware, endless neo print gasket, 2nos. of cable entry, stopping plugs, earthing terminals, installation hardware and all necessary accessories wired upto terminal box. Integral plug tops shall be also supplied with the power socket outlets. All switch sockets shall be provided with Canopy of 14 gauge CRCA sheet with side cover and required no. of FLP double compression Ni plated brass cable glands and FLP stopping plug as per attached specification sheets.

-

-

-

... More
415 V AC, 3 phase, 63A, (3P+N+E), 50 Hz

5

-

39200

... More
16A. 230 V AC, 1 phase(1P +N+E), 50 Hz,

2

-

11100

... More
6A. 230 V AC, 1 phase(1P +N+E), 50 Hz,

2

-

10125

... More
INDUSTRIAL POWER SOCKET OUTLETS WITH INTEGRAL PLUG TOPS (WEATHERPROOF, NON-FLAMEPROOF TYPE): Design, Supply, Installation, Testing & Commissioning of Power Socket outlets shall be Non-Flame proof, industrial type (IP65) interlocked with MCB and ELCB and suitable for loop-in loop-out entries for armoured cable as specified enclosed with Cast Aluminium alloy (LM-6 grade) with stainless steel hardware, endless neo print gasket, 2nos. of cable entry, stopping plugs, earthing terminals, installation hardware and all necessary accessories wired upto terminal box. Integral plug tops shall be also supplied with the power socket outlets. All switch sockets shall be provided with Canopy of 14 gauge CRCA sheet with side cover and required no. of double compression Ni plated brass cable glands and stopping plug as per attached specification sheets.

-

-

-

... More
415 V AC, 3 phase, 63A, (3P+N+E), 50 Hz

2

-

17700

... More
16A. 230 V AC, 1 phase (1P +N+E),, 50 Hz,

2

-

8500

... More
6A. 230 V AC, 1 phase (1P +N+E), 50 Hz,

2

-

6225

... More
OUTDOOR NORMAL POWER DB (NON-FLAMEPROOF, WEATHERPROOF TYPE): Design, Supply, Installation, Testing & Commissioning of 415V, 3Ph & N, 10kA 1 sec, wall or frame mounted, IP 65 protected, Non-compartmentalised, Double door, Weatherproof, Power Panels enclosure shall be made up of cast Aluminium alloy (LM6 grade) with Canopy of 14 gauge CRCA with side cover, along with Weatherproof double compression Ni plated brass cable glands and lugs, PVC shrouds, suitable for bottom cable entry complete in all respect as per attached Specification/Data sheet of Tender. Incomer- 32A, 4P, MCB- 1 no, Sub Incomer- 32A, DP RCCB with 30mA sensitivity - 3 Nos. Outgoings- 10A DP MCB-6 nos, (2 nos/ Phase)

1

-

113650

... More
OUTDOOR NORMAL POWER DB (FLAMEPROOF, WEATHERPROOF TYPE): Design, Supply, Installation, Testing & Commissioning of 415V, 3Ph & N, 10kA 1 sec, wall or frame mounted, IP 65, Flameproof “Ex-d” (suitable for hazardous area of gas group IIA/IIB, temperature class T3 and Zone-2) Power Panel enclosure Aluminium alloy (LM6) enclosure with Canopy of 14 gauge CRCA with side cover, Non-compartmentalised, Double door, along with Flameproof double compression Ni plated brass cable glands and lugs, PVC Shrouds suitable for bottom cable entry complete in all respect as per attached Specification/Data sheet of Tender. Incomer- 63A, 4P, MCB- 1 no, Sub Incomer- 63A, DP RCCB with 30mA sensitivity - 3 Nos. Outgoings- 16A DP MCB-6 nos, (2 nos/ Phase)

1

-

259000

... More
HIGH MAST TOWER LIGHTING SYSTEM

-

-

-

... More
20 Mtr. height High Mast Tower: Design, Supply, Installation and testing and commissioning of 20 Mtr. height High Mast Tower (hot dip galvanized, base metal thickness not less than 4 mm), Outdoor type, with provision of 2x8 nos of 400 W NON FLP LED types of luminaires in two layers and its control gear box complete with accessories as per specifications/datasheet of Tender. The cost also includes supplying and providing trailing cable of suitable size & length from Switch Plug & Socket at the foot of high mast to the junction box at the top, FLP Motor, suitable size double compression Ni plated brass cable glands and lugs, PVC shrouds, etc. Note: a) The civil works required for high mast foundations are excluded from scope of this item and shall be paid separately. b) The item includes the S/I of raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightening finial (Lightening arrestor), including low intensity LED type double dome aviation obstruction light. c) Tenderers should note that junction box shall be provided at the top of the high mast as per specifications. Rates for lighting fixtures and earth pits shall be paid separately. d) Bidder to provide design and drawing for High Mast Tower and foundation of high mast tower. e) The high Mast system shall be suitable for wind speed of the location as per IS-875, with head frame, winch mounting bracket, luminaries carriage suitable to install 16 nos. 400W LED FLD in Symmetrical arrangement (0-360Deg). e) The scope includes the supply foundation bolts manufactured from EN 8 grade galvanised steel along with nuts, washers, anchor plate and common template. f) Provision of lowering/raising of light fixutures without removal of cable end termination, complete with accessories as per attached specification of this tender.

13

-

641875

... More
12 Mtr. height High Mast Tower: Design, Supply, Installation and testing and commissioning of 12 Mtr. height High Mast Tower (hot dip galvanized, base metal thickness not less than 4 mm), Outdoor type, with provision for 2x7 nos of 275W NON FLP LED types of luminaires in two layers and its control gear box complete with accessories as per specifications/datasheet of Tender. The cost also includes supplying and providing trailing cable of suitable size & length from Switch Plug & Socket at the foot of high mast to the junction box at the top, Non-FLP Motor, suitable size double compression Ni plated brass cable glands and lugs, PVC shrouds, etc. Note: a) The civil works required for high mast foundations are excluded from scope of this item and shall be paid separately. b) The item includes the S/I of raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightening finial (Lightening arrestor), including low intensity LED type double dome aviation obstruction light. c) Tenderers should note that junction box shall be provided at the top of the high mast as per specifications. Rates for lighting fixtures and earth pits shall be paid separately. d) Bidder to provide design and drawing for High Mast Tower and foundation of high mast tower. e) The high Mast system shall be suitable for wind speed of the location as per IS-875, with head frame, winch mounting bracket, luminaries carriage suitable to install 14 nos. 400W LED in Symmetrical arrangement (0-360Deg). e) The scope includes the supply foundation bolts manufactured from EN 8 grade galvanised steel along with nuts, washers, anchor plate and common template. f) Provision of lowering/raising of light fixutures without removal of cable end termination, complete with accessories as per attached specification of this tender.

7

-

377325

... More
Flameproof Outdoor Feeder Pillar Panel: Design, Supply, Installation and testing and commissioning of flameproof outdoor distribution board (Feeder Pillar Panel), made up of cast Aluminium alloy (LM6 grade) with Canopy of 14 gauge CRCA with side cover, IP-65, stand mounted, with timer contactor, Auto manual selector switch and control mcb, 1 no. 32A TPN MCB incomer, single dial time switch, 22A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, required cabling/termination from Panel to light fitting and required GI pipes, provision of Incoming, Outgoing and for Looping and FLP type industrial socket with associated civil works like foundation etc. Note: Necessary Civil /Structural Works shall be paid seperately).

13

-

150000

... More
Weatherproof Outdoor Feeder Pillar Panel: Design, Supply, Installation and testing and commissioning of weatherproof outdoor distribution board (Feeder Pillar Panel), made of 14 SWG CRCA sheet, IP-65, stand mounted, with timer contactor, Auto manual selector switch and control mcb, with 1 no. 32A TPN MCB incomer, single dial time switch, 22A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, required cabling/termination from Panel to light fitting and required GI pipes, provision of Incoming, Outgoing and for Looping and non-FLP type industrial socket with associated civil works like foundation etc. Note: Necessary Civil /Structural Works shall be paid seperately).

7

-

96000

... More
LED Flood Light: Supply, Installation , Testing and commissioning of high-quality integrated LED Flood Light with a minimum system lumen of 53000 Lm and system wattage of nominal 400W with a nominal efficiency 130 lumen/watt. CCT of 5700K with SDCM of 5 and CRI : 70. The housing should be of non-corrosive high-pressure die-cast aluminum to with stand extreme environments. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. with PF 0.95. Lifetime of 75K hours @L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have a 20 KV /10 kA SPD duly bolted in theLuminaire. The SPD should be able to sustain a minimum 15 hits of 10kA rating i.e., Total of 45 hits across all the three modes as per IEEE 62.41.2. The Luminaire should have a breather to ensure that air balance inside and outside of the Compartment .The luminaire should be of Class B Serviceability. The wattage of each LED should be greater than 1 watt and less than 3 Watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , midpower ,Integrated arrays and COBs are not permitted. The High-power LED used in the luminaire shall be SMD type only of make LGIT, Lumileds, Osram, Nichia, and CREE & no other make. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. The Dimension of the luminaires should be minimum 595 x 100 x418 mm and have a breather ensuring a stable optical and thermal management. Model no. BVP485 LED530 CW FLNB A1 PSU GR SPD of Philips or equivalent make

208

-

40500

... More
LED Flood Light: Supply, Installation , Testing and commissioning of high-quality integrated LED Flood Light with a minimum system lumen of 53000 Lm and system wattage of nominal 275W with a nominal efficiency 130 lumen/watt. CCT of 5700K with SDCM of 5 and CRI : 70. The housing should be of non-corrosive high-pressure die-cast aluminum to with stand extreme environments. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. with PF 0.95. Lifetime of 75K hours @L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have a 20 KV /10 kA SPD duly bolted in theLuminaire. The SPD should be able to sustain a minimum 15 hits of 10kA rating i.e., Total of 45 hits across all the three modes as per IEEE 62.41.2. The Luminaire should have a breather to ensure that air balance inside and outside of the Compartment .The luminaire should be of Class B Serviceability. The wattage of each LED should be greater than 1 watt and less than 3 Watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , midpower ,Integrated arrays and COBs are not permitted. The High-power LED used in the luminaire shall be SMD type only of make LGIT, Lumileds, Osram, Nichia, and CREE & no other make. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. The Dimension of the luminaires should be minimum 595 x 100 x418 mm and have a breather ensuring a stable optical and thermal management. Model no. BVP485 LED530 CW FLNB A1 PSU GR SPD of Philips or equivalent make

98

-

30300

... More
LIGHTING SYSTEM (OUTDOOR / INDOOR)

-

-

-

... More
STREET LIGHT POLES :

-

-

-

... More
Design, Supply, installation and Commissioning of Polygonal / Octagonal Street lighting poles (Hot dip Galvanization 610 gms / sq. mt. or as per IS-2629 & IS-4759/ISO 1461) as per attached specification of this tender, including cable termination and connection, fixing of cable glands and lugs, PVC Shrouds, suitable for mounting 100W/120W/150W LED Light Fixtures with all accessories, all labor and materials, complete in all respect as per attached Specification/Data sheet of Tender. Note: Civil Works shall be paid seperately.

-

-

-

... More
Single arm Polygonal / Octagonal street pole: 7 Meter high galvanised Polygonal / Octagonal Street Light Pole with Single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade Galvanised foundation bolts and anchor plate having fixing arrangement for mounting 1 Nos. of LED luminaries as per enclosed technical specifications. The item also includes suitable fixing/clamping arrangement made up of GI on the body of the Light Pole for fixing of requisite flameproof or weatherproof junction boxes with terminals block with additional earthing terminals and end clamps etc. including 4 Nos double compression cable glands / Plug, lugs with PVC shrouds suitable size of Cable (XLPE, FRLS), complete with all accessories suitable for Hazardous Zone-2 area alongwith associated jobs etc. The payment for the Junction Box, light fixtures, cables shall be made seperately.

25

-

25396

... More
Double arm Polygonal / Octagonal street pole: 7 Meter high galvanised Polygonal / Octagonal Street Light Pole with double arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade Galvanised foundation bolts and anchor plate having fixing arrangement for mounting 1 Nos. of LED luminaries as per enclosed technical specifications. The item also includes suitable fixing/clamping arrangement made up of GI on the body of the Light Pole for fixing of requisite flameproof or weatherproof junction boxes with terminals block with additional earthing terminals and end clamps etc. including 4 Nos double compression cable glands / Plug, lugs with PVC shrouds suitable size of Cable (XLPE, FRLS), complete with all accessories suitable for Hazardous Zone-2 area alongwith associated jobs etc. The payment for the Junction Box, light fixtures, cables shall be made seperately.

18

-

26677

... More
Supply, Installation, testing & commissioning of 7 mtr. high galvanised Polygonal / Octagonal Street Light Pole with Single Arm of 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade Galvanised foundation bolts and anchor plate having fixing arrangement for ground mounting suitable for mounting light fixtures including 150W LED Solar type Fixture & Junction box, VRLA Battery (72 hrs backup time) with weatherproof nickel plated brass cable gland, tinned copper lugs of suitable type & size for termination, weather proof JB at the foot of pole including MCB & terminal block (as applicable), cables from foot of the pole to the light fittings complete with all accessories, GI pipe (Class B) for cable protection, Zinc passivated hardware for fixtures support & pole support, clamps, nuts, bolts, etc. including supply of commissioning spares, as required. The payment for the Junction Box, light fixtures, cables shall be made seperately.

10

-

33150

... More
GOOSE / SWAN NECK TYPE POLE (SUITABLE FOR WELL GLASS LIGHTING FIXTURE): 2.5 mtr high hot dip galvanised, goose neck type lighting pole (50mm as per IS 1239 - Medium duty) alongwith with Junction Box suitable for for structural / handrail mounting , complete with all clamping arrangements for cables including accessories , flameproof proof JBs at the foot of the pole & termination block (as applicable), zinc passivated hardware for fixtures support & pole support , clamps, nuts, bolts, etc. including supply of commissioning spares , as required for 1 nos.of well glass light luminaires. The junction box shall be complete with terminals for loop-in loop-out of cables. The terminals shall be pre-wired upto the luminaire using 1100V grade, 3Cx2.5/4 sqmm. stranded copper, PVC insulated, extruded FRLS PVC inner & outer sheathed. The payment for the light fixtures, cables shall be made seperately.

25

-

9469

... More
LIGHT FIXTURES :

-

-

-

... More
Design, Supply, Installation, Testing & Commissioning of flameproof/weatherproof Luminaries (lighting fixtures) of approved makes as per the specification including receiving from store, transporting to erection site including handling, arrangement of transport vehicle, unpacking, inspection, checking of internal wiring, cable glanding and termination, crimping of lugs and connections at fixtures/ control gears, supply of all erection materials including necessary GI hardware, GI clamps, GI brackets, civil masonry materials, testing of following types of lighting fixtures with all their parts and accessories etc, including fixing of lamps, all work, labour and materials, complete as per drawings and specification of this tender and directions of Engineer in charge. The item also includes the design & submission of the design/LUX level report as per the provisions of OISD for the entire plant area/sheds/buildings etc. including finalization of locations/coordinates of the high masts based on the selected lumanaires. The design must be submitted for approval from IOCL/PMC. (All Lighting fixtures shall be provided with required no. of double compression nickle plated brass cable glands, lugs and stopping plug.)

-

-

-

... More
Outdoor area lighting, Weatherproof and Flame proof (Ex"d" suitable for Gas group IIA/IIB, T3, suitable for Zone 2) 150W LED Industrial flood light fixture suitable for 7 m Single/Double arm light pole, mountings enclosure with toughened glass, SS wire guard, stainless steel hardware, earthing terminal, installation hardware and all necessary accessories wired up to terminal box, lamps & accessories, complete in all respects as per attached specifications / data sheet of the Tender.

55

-

24975

... More
Outdoor area lighting, Weatherproof 150W LED Industrial flood light fixture suitable for 7 m Single/Double arm light pole, mountings enclosure with toughened glass, SS wire guard, stainless steel hardware, earthing terminal, installation hardware and all necessary accessories wired up to terminal box, lamps & accessories, complete in all respects as per attached specifications / data sheet of the Tender.

5

-

14175

... More
Outdoor type, Weatherproof and Flame proof (Ex"d" suitable for Gas group IIA/IIB, T3, suitable for Zone 2) 60 W LED well glass light fixture, mountings enclosure with toughened glass, SS wire guard, stainless steel hardware, earthing terminal, installation hardware and all necessary accessories wired up to terminal box, suitable for mounted on structure including wiring light fixture complete in all respects.

150

-

11475

... More
Outdoor type, Weatherproof and Flame proof (Ex"d" suitable for Gas group IIA/IIB, T3, suitable for Zone 2) 72 W LED well glass light fixture, mountings enclosure with toughened glass, SS wire guard, stainless steel hardware, earthing terminal, installation hardware and all necessary accessories wired up to terminal box, suitable for mounted on structure including wiring light fixture complete in all respects.

20

-

11863

... More
Outdoor type, weather Proof 30 W LED bulk head fitting with reflector and its accessories etc suitable for mounted on structure including wiring light fixture complete in all respects.

20

-

4818

... More
Outdoor type, Flame proof (Ex"d" suitable for Gas group IIA/IIB, T3, suitable for Zone 2) 2 x 20 W LED, Industrial type lighting fixtures with LED lamp and all other accessories as per specification.

4

-

21000

... More
36W Weatherproof LED Batten Light suitable for Ceiling/Pole/Structure/MS bracket/Rod/Pipe mountings

12

-

3720

... More
80W LED undercanopy light (Outdoor type) suitable for surface / recessed mounting from structure

10

-

12500

... More
Outdoor type, Flame proof (Ex"d" suitable for Gas group IIA/IIB, T3, suitable for Zone 2) FLP 100 W GLS,110V DC , well glass type light fittings with reflector and its accessories etc.

6

-

8850

... More
Outdoor type, weather Proof 60 W GLS,110V DC, bulk head type light fittings with reflector and its accessories etc.

5

-

4125

... More
DC Lighting Design, Supply, Installation, Testing & Commissioning of Weather proof 12V DC lamp with integral charger for FWPH/PMCC/Control Room & Security Room.

16

-

9000

... More
CABLE SUPPLY, LAYING & TERMINATIONS :

-

-

-

... More
HT Power Cables: Design, Supply and Laying of 11 kV(E) grade, stranded, multicore, Al. Conductor, conductor scrren, XLPE insulated, Insulation screen, PVC inner sheath, steel wire armoured, PVC outer sheathed H.T. power cables as per IEC 60502-2 / IS 7098-2 of following sizes in ground/tray including fixing of strip number tags, fixing of saddles and saddle bars, protective tiles etc. including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per attached specification of this tender and directions of Engineer-in- charge. Before procurring the cable, Contractor to make cable schedule as per site conditions and get approved by IOCL/Consultant. The item also includes cable Tag 2mm thick Aluminium with No. punched on it and shall be securely attached to the cable by not less than two turns of 20 SWG GI wire conforming to IS 280.

-

-

-

... More
3C X 240 mm2 11 KV (E) Grade Cable

150

-

3526

... More
Supply, installation, testing and commissioning of outdoor termination kit for 3C X 240 mm2 11 KV (E) Al. Grade Cable

2

-

29775

... More
Supply, installation, testing and commissioning of indoor termination kit for 3C X 240 mm2 11 KV (E) Al. Grade Cable

2

-

21675

... More
LT Power Cables (FRLS): Design, Supply, laying, termination, testing and commissioning, restoration of 1.1kV grade, XLPE insulated, stranded Cu / Al. Conductor, steel wire/strip (for multi core) armoured, for power cable, control cable and signal cable, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and tender specification) along with Glanding & Cable termination, connection of Double compression nickel plated brass Cable gland (FLP/Weather proof gland as per requirement) and nickel plated lugs & termination, silicon based jointing kit as per cable schedule(will be provided detail engineering) of following sizes in ground/trenches/tray, pulling through pipes and its proper sealing etc. including fixing of strip number tags, fixing of saddles and saddle bars, protective tiles etc. including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, and completeness with all aspect as per attached specifications directions of Engineer-in- charge. The item includes cable Tag 2mm thick Aluminium with No. punched on it and shall be securely attached to the cable by not less than two turns of 20 SWG GI wire conforming to IS 280. The same shall be attached @ max. 30m or at bends whichever is lesser. Note: a) Before procuring cable, successfull bidder is required to prepare detailed BOQ, cable schedule & Drum Schedule of Cables as per site mesaurement and get approved by IOCL/Consultant. No extra payment shall be made for wastages. b) Payment shall be paid separately for Supply of FLP/WP Industrial Glands. Glands shall be supplied with PVC hood. Diameter of cable under armour and above armour shall be checked prior to ordering of glands. Glands shall be complete with double seal cone-grip arrangements and check nuts.

-

-

-

... More
1Cx 630 mm2 A2XFY

1400

-

1926

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 1Cx 630 mm2 A2XFY

4

-

3600

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 1Cx 630 mm2 A2XFY

28

-

2790

... More
3.5 Cx 630 mm2 A2XFY

750

-

5264.35

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 3.5Cx 630 mm2 A2XFY

4

-

5925

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 3.5 Cx 630 mm2 A2XFY

6

-

4980

... More
3 C x 400 mm2 A2XFY

6500

-

3166

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 3 C x 400 mm2 A2XFY

10

-

5000

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 3 C x 400 mm2 A2XFY

10

-

4170

... More
3 C x 300 mm2 A2XFY

1000

-

2484

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 3 C x 300 mm2 A2XFY

4

-

4410

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 3 C x 300 mm2 A2XFY

4

-

3397.5

... More
3 C x 95 mm2 A2XFY

950

-

882

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 3 C x 95 mm2 A2XFY

20

-

2500

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 3 C x 95 mm2 A2XFY

4

-

1744

... More
3 C x 70 mm2 A2XFY

2000

-

722

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 3 C x 70 mm2 A2XFY

4

-

2000

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 3 C x 70 mm2 A2XFY

12

-

1459

... More
3 C x 50 mm2 A2XFY

1750

-

536

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 3 C x 50 mm2 A2XFY

2

-

1500

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 3 C x 50 mm2 A2XFY

6

-

1207.5

... More
3 C x 35 mm2 A2XFY

750

-

416

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 3 C x 35 mm2 A2XFY

4

-

1537.5

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 3 C x 35 mm2 A2XFY

4

-

887

... More
3.5 Cx 300 mm2 A2XFY

3000

-

2820

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 3.5 C x 300 mm2 A2XFY

6

-

4545

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 3.5 C x 300 mm2 A2XFY

64

-

3397.5

... More
3.5Cx 240 mm2 A2XFY

2500

-

2400

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 3.5 C x 240 mm2 A2XFY

4

-

3882

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 3.5 C x 240 mm2 A2XFY

12

-

3127.5

... More
3.5Cx 120 mm2 A2XFY

600

-

1400

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 3.5 C x 120 mm2 A2XFY

4

-

2977.5

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 3.5 C x 120 mm2 A2XFY

4

-

2029

... More
3.5 Cx 95 mm2 A2XFY

2000

-

1006

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 3.5 C x 95 mm2 A2XFY

6

-

1922

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 3.5 C x 95 mm2 A2XFY

10

-

1720

... More
3.5Cx 70 mm2 A2XFY

6500

-

812

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 3.5 C x 70 mm2 A2XFY

10

-

2000

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 3.5 C x 70 mm2 A2XFY

10

-

1372

... More
3.5 Cx 50 mm2 A2XFY

6500

-

615

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 3.5 C x 50 mm2 A2XFY

4

-

1132

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 3.5 C x 50 mm2 A2XFY

20

-

932

... More
4Cx 35 mm2 A2XFY

2000

-

523

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 4 C x 35 mm2 A2XFY

6

-

1350

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 4 C x 35 mm2 A2XFY

8

-

835

... More
4Cx 25 mm2 A2XFY

6000

-

405.5

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 4 C x 25 mm2 A2XFY

12

-

1300

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 4 C x 25 mm2 A2XFY

20

-

770

... More
4Cx 16 mm2 A2XFY

1500

-

315

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 4 C x 16 mm2 A2XFY

4

-

956

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 4 C x 16 mm2 A2XFY

10

-

652

... More
4Cx 10 mm2 A2XFY

1000

-

293

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 4 C x 10 mm2 A2XFY

8

-

535

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 4 C x 10 mm2 A2XFY

16

-

509

... More
4Cx 6 mm2 2XWY

750

-

640

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 4 C x 6 mm2 2XWY

4

-

484

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 4 C x 6 mm2 2XWY

4

-

433

... More
4Cx 4 mm2 2XWY

3200

-

459

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 4Cx 4 mm2 2XWY

10

-

417

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 4Cx 4 mm2 2XWY

22

-

406

... More
4Cx 2.5 mm2 2XWY

22000

-

325

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 4Cx 2.5 mm2 2XWY

200

-

405

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 4Cx 2.5 mm2 2XWY

100

-

405

... More
3Cx 2.5 mm2 2XWY

12000

-

263

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 3Cx 2.5 mm2 2XWY

80

-

405

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 3Cx 2.5 mm2 2XWY

40

-

405

... More
3C x 6 mm2 2XWY (Air Conditioning unit, 1 phase power receptacles etc.)

300

-

510

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 3C x 6 mm2 2XWY

10

-

484

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 3C x 6 mm2 2XWY

10

-

433

... More
7C x 2.5 mm2 Cu PVC insulated, FRLS PVC outer sheath, armored cable - control cable

6000

-

600

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 7C x 2.5 mm2 Cu PVC insulated, FRLS PVC outer sheath, armored cable

10

-

484

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 7C x 2.5 mm2 Cu PVC insulated, FRLS PVC outer sheath, armored cable

30

-

433

... More
12C x 2.5 mm2 Cu PVC insulated, FRLS PVC outer sheath, armored cable - control cable

3500

-

822

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 12C x 2.5 mm2 Cu PVC insulated, FRLS PVC outer sheath, armored cable

10

-

575

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 12C x 2.5 mm2 Cu PVC insulated, FRLS PVC outer sheath, armored cable

40

-

524

... More
24C x 2.5 mm2 Cu PVC insulated, FRLS PVC outer sheath, armored cable - control cable

500

-

1579

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 24C x 2.5 mm2 Cu PVC insulated, FRLS PVC outer sheath, armored cable

2

-

1074

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 24C x 2.5 mm2 Cu PVC insulated, FRLS PVC outer sheath, armored cable

10

-

946

... More
3Cx 25 mm2 A2XFY

500

-

390.71

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland cable Gland for 3Cx 25 mm2 A2XFY

4

-

1019

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 3Cx 25 mm2 A2XFY

8

-

922.5

... More
2C x 2.5 mm2 Cu PVC insulated, FRLS PVC outer sheath, armored cable - control cable

500

-

264.19

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 2C x 2.5 mm2 Cu PVC insulated, FRLS PVC outer sheath, armored cable

2

-

410

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 2C x 2.5 mm2 Cu PVC insulated, FRLS PVC outer sheath, armored cable

10

-

410

... More
LT Cables FR (Fire Resistant): Design, Supply, laying, termination, testing and commissioning of 1.1kV grade, stranded Cu Conductor, Fire Resistant XLPE insulated, steel wire/strip (for multi core) armoured, for power cable, control cable and signal cable, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and tender specification) along with Glanding & Cable termination, connection of Double compression nickel plated brass Cable gland (FLP/Weather proof gland as per requirement) and nickel plated lugs & termination, silicon based jointing kit as per cable schedule(will be provided detail engineering) of following sizes in ground/trenches/tray, pulling through pipes and its proper sealing etc. including fixing of strip number tags, fixing of saddles and saddle bars, protective tiles etc. including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, and completeness with all aspect as per attached specifications directions of Engineer-in- charge. The item includes cable Tag 2mm thick Aluminium with No. punched on it and shall be securely attached to the cable by not less than two turns of 20 SWG GI wire conforming to IS 280. The same shall be attached @ max. 30m or at bends whichever is lesser. Cables: FR/FS to be used as per OISD provisions inside the dyke. Note: a) Before procuring cable, successfull bidder is required to prepare detailed BOQ, cable schedule & Drum Schedule of Cables as per site mesaurement and get approved by IOCL/Consultant. No extra payment shall be made for wastages. b) Payment shall be paid separately for Supply of FLP/WP Industrial Glands. Glands shall be supplied with PVC hood. Diameter of cable under armour and above armour shall be checked prior to ordering of glands. Glands shall be complete with double seal cone-grip arrangements and check nuts.

-

-

-

... More
4Cx 2.5 mm2 2XWY

500

-

331

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 4Cx 2.5 mm2 2XWY

20

-

410

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 4Cx 2.5 mm2 2XWY

20

-

410

... More
4Cx 6 mm2 2XWY

3500

-

700

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 4Cx 6 mm2 2XWY

110

-

503

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 4Cx 6 mm2 2XWY

20

-

447

... More
4Cx 16 mm2 A2XFY

1000

-

700

... More
Supply of Flameproof (IP65) type Double compression nickel plated brass Cable gland for 4Cx 16 mm2 A2XFY

20

-

615

... More
Supply of Weatherproof (IP55) type Double compression nickel plated brass Cable gland for 4Cx 16 mm2 A2XFY

20

-

554

... More
GALVANIZED CABLE TRAYS

-

-

-

... More
CABLE TRAYS (LADDER TYPE) Design, Supply & Installation of Hot dip G.I. LADDER TYPE cable trays of minimum 2.5 mtr length (width 100 mm side flange height for cable tray of width 300 mm and above and 75 mm side flange height for cable below 300 mm) with requisite runners and slotted rungs at 300mm spacing, Min.2500mm length along with required Coupler Plate with stainless Hard-ware, Hold on clamps With stainless Hard- ware, Horizontal /Vertical - Inside / Outside bends, Straight run, Tees etc. etc. suitable for following G.I. Cable Tray width as per attached specification/drawings of this tender and direction of Engineer-in-charge. Item includes all accessories, i.e. Coupler plate, Tray Fixing clamp,Fastener, nut, bolt washer etc. as required. All the hardware i.e. Fasterener, Nut, Bolt, Washers etc. shall be of SS 304. Minimum thickness of galvanisation shall be 610 gm/m2 or or as per IS-2629 & IS-4759/ISO 1461. BIDDER to note that all the accessories mentioned above shall be paid in running meters of cable tray lengths. Separate rate for supply of such accessories shall not be paid.

-

-

-

... More
600mm wide x 2.5 mm thick - Ladder Type

3250

-

1661.25

... More
300mm widex 2.5 mm thick-Ladder Type

3250

-

1278

... More
150mm wide x 2.5 mm thick-Ladder Type

1500

-

1095

... More
Design, Supply & Installation of of 1.6 mm thick Hot dip G.I. Cable Tray Cover of minumum 2.5 M length suitable for Cable tray of following sizes including clamps for fixing the cover to cable tray with all accessories. Minimum thickness of galvanisation shall be 610 gm/m2 or or as per IS-2629 & IS-4759/ISO 1461

-

-

-

... More
600mm wide - Ladder Type

2500

-

1345.5

... More
300mm wide-Ladder Type

2750

-

990

... More
150mm wide-Ladder Type

100

-

690

... More
CABLE TRAYS (PERFORATED TYPE): Design, Supply & Installation of Hot dip G.I. PERFORATED TYPE cable trays of minimum 2.5 mtr length (width 100 mm side flange height for cable tray of width 300 mm and above and 75 mm side flange height for cable below 300 mm) at length for Straight run, bends, Tees etc. as per enclosed specification & drawings. Item includes all accessories, i.e. Coupler plate, Tray Fixing clamp,Fastener, nut, bolt washer etc. as required. All the hardware i.e. Fasterener, Nut, Bolt, Washers etc. shall be of SS 304.Minimum thickness of galvanisation shall be 610 gm/m2 BIDDER to note that all the accessories mentioned above shall be paid in running meters of cable tray lengths. Separate rate for supply of such accessories shall not be paid.

-

-

-

... More
600mm wide x 2.5mm thick - Perforated Type with cover (1.6mm thick)

2000

-

3825

... More
300mm wide x 2.5mm thick -Perforated Type with cover (1.6mm thick)

3500

-

2805

... More
150mm wide x 2.5mm thick -Perforated Type with cover (1.6mm thick)

1500

-

1704

... More
100mm wide x 2.5mm thick -Perforated Type with cover (1.6mm thick)

1000

-

1305

... More
50mm wide x 2.5mm thick -Perforated Type with cover (1.6mm thick)

750

-

1004

... More
MULTI CABLE TRANSIT (MCT) Block

-

-

-

... More
Multi Cable Transit (MCT) Blocks: Design, Supply & Installation of MCT block with SS Frame with EPDM Modules, Stay plate, Compression wedge, Lubricant etc complete with all accessories for following area as per the respective cable schedule/sizes for cable entry Buildings (Control  Room, PMCC, Admin Building, Invoice Room, Security Room, Driver's Rest Room & any other etc) with minimum 30% spare MCT blocks for future cable entry along with frame and mounting accessories complete as per specification of tender.

-

-

-

... More
MCT Block (for LT Power Cables- 24 incomer/outoging Cables + 30% Spare blocks )

1

-

110250

... More
MCT Block (for LT Power cables -12 incomer/outoging Cables + 30% Spare blocks)

1

-

90000

... More
MCT Block (for LT Power cables - 6 incomer/outoging Cables + 30% Spare blocks)

2

-

73050

... More
MCT Block (for LT Power cables - 3 incomer/outoging Cables + 30% Spare blocks)

3

-

56250

... More
BUILDING INTERNAL WIRING FOR LIGHTING, SOCKET, EXHAUST FAN & AIR CONDITIONER

-

-

-

... More
Design, Supply, installation, testing, commissioning of 230V, Non Flame proof integral/ Non integral well glass type fixture high bay type with 80 W LED lamp mountings enclosure with toughened glass, SS wire guard, stainless steel hardware, earthing terminal, installation hardware and all necessary accessories including weather proof double compressor cable gland wired up to terminal box, suitable for mounted on structure including wiring light fixture complete in all respect with all accessories.

24

-

9942

... More
Design, Supply, installation, testing, commissioning of 230V, Weatherproof and Flame proof (Ex"d" suitable for Gas group IIA/IIB, T3, suitable for Zone 2) Flame proof integral/ Non integral well glass type fixture high bay type with 80 W LED lamp mountings enclosure with toughened glass, SS wire guard, stainless steel hardware, earthing terminal, installation hardware complete with all accessories including FLP,weather proof double compressor cable gland wired up to terminal box, suitable for mounted on structure including wiring light fixture complete in all respect with all accessories.

14

-

21050

... More
Design, Supply, Installation, testing & commissioning of indoor type, surface/recess type 36 W LED fixture with including wiring light fixture complete in all respects. Suitable for indoor.

35

-

5000

... More
Design, Supply, Installation, testing & commissioning of indoor type, surface/recess type 110V DC light 36 W LED fixture with suitable size of JB including wiring light fixture complete in all respects. Suitable for indoor.

10

-

11550

... More
Supply, Fixing & Commissioning of 450 mm dia., heavy duty Flame proof Ex'd' exhaust fan complete with motor, cable gland, shutter, louver, bird catcher, mounting bracket, hardware etc. and conforming to IS, heavy duty type suitable for 240V, single phase AC supply. The fans shall be with louvers / shutters.(The job does include making suitable cut out in the wall for fixing the fan).

4

-

49500

... More
Supply, Fixing & Commissioning of 600 mm dia Industrial exhaust fan including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters. (The job does include making suitable cut out in the wall for fixing the fan).

4

-

15020

... More
Supply, Installation of 25 mm PVC Conduit (concealed) for lighting

500

-

162.75

... More
Supply, Installation of 50 mm PVC Conduit (concealed) for lighting

100

-

284

... More
Supply, Installation of 20mm / 25mm Dia. Galvanized Rigid Conduit

750

-

183

... More
Supply, Fabrication & Installation of MS CHEQUERED PLATE of 6 mm thick on cable trench inside swtich room, DG room, earthing pit including cutting, painting, lifting hooks, etc and painting as per Tender specifications.

500

-

6000

... More
HDPE Pipe Supply & laying of Heavy Duty type, High compression strength, IP 67 rated (DWC) Double wall corrugated HDPE Conduits as per IS:14930/ IS:16205. Laying includes with GI pull wires inside the conduits & necessary ends to be filled with sealants, cutting, bending and similar works, supply of clamps, spacers, including all labour and materials complete as per drawings and directions of Engineer-In-Charge for the following sizes of HDPE Pipe in required length.

-

-

-

... More
50 mm NB

500

-

206

... More
100 mm NB

300

-

426

... More
150 mm NB

300

-

700

... More
GI Pipe Supply & laying B-class G.I. pipe conforming to IS: 1239 for cable protection including laying inside concrete including cutting, bending and similar works, supply of clamps, spacers and all labour and materials complete as per drawings and directions of Engineer-In-Charge for the following sizes of GI Pipe in required length

-

-

-

... More
50 mm NB

200

-

1110

... More
100 mm NB

250

-

1739

... More
150 mm NB

150

-

2700

... More
Supply and installation of the following including the supply of necessary clamp , bolts and hardware,Breaking and repair of walls, if required, and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules.

-

-

-

... More
Caution boards (Danger, High Voltage) to be provided in Hindi, English and local language as per IS 2551

2

-

1027.5

... More
Shock hazard charts complete in glass frame to be provided in Hindi, English and local language.as per IS 5216-2 (1982) & SP 31 (1986)

2

-

1500

... More
Single Line Diagram complete in glass frame (A0 size) as per IS 2553-1

1

-

2850

... More
Supply of Tools and Instrument ( Multi meter, earthing megger, insulation megger, IS marked tester, one set of different shape of screw driver, one set of nut &bolt wrench.)

1

-

42000

... More
Supply and laying of Insulating Mats 11kV grade 3mm thick (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in station as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge, as per applicable Indian or International standards and Indian Electricity Rules.

30

-

2850

... More
Supply and laying of Insulating Mats 1.1kV grade 2mm thick (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in station as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge, as per applicable Indian or International standards and Indian Electricity Rules.

500

-

1846

... More
Supplying and fixing of GI Fire Buckets, painted in PO red outside and white inside, complete with handle, fixing brackets etc (3 buckets).

5

-

4651

... More
Supply of First aid box of GI, 18 SWG sheet with Snake serum as per IS 13115(B) & IS 5216-2 (1982)

2

-

4005

... More
Supply and fixing of Fire extinguishers CO2 type in 4.5kg capacity complete with handle , fixing bracket etc.

2

-

6890

... More
Supplying and fixing of Fire extinguishers DCP type (10 kg capacity)

2

-

11625

... More
Supply of 11 kV grade hand gloves, ISI mark,as per IS 13774 & IEC

3

-

8925

... More
Supply of 415 V grade hand gloves, ISI mark,as per IS 13774 & IEC

3

-

2175

... More
Motor is erected by mechanical contractor at erection site. However, scope of electrical contractor excluding cable glanding & power / control cable termination but including dehydration of windings (If required), plugging unused cable gland cutout in motor terminal box, checking & replenishment / replacement of bearing grease / lubricant, checking of IR values between each winding & motor frame, checking of continuity of motor windings, checking of direction of rotation, motor shall run in uncoupled condition for 8 hrs. & changing of direction of rotation (If required by changing supply connections), trial runs on NO - LOAD & LOAD test, supply of approved grease / lubricant, installing of canopy, necessary hardware’s, testing & commissioning of following LT MOTORS together with all accessories, all works, labour and materials complete as per drawings & documents, specifications, codes & standards and instructions / directions of ENGINEER IN CHARGE. (Contactor to keep proper record of tests on motord for NO - LOAD & ON - LOAD runs.)

-

-

-

... More
415V, 1.1 kW

3

-

4500

... More
415V, 11 kW

2

-

12000

... More
415V, 22 kW

2

-

27000

... More
415V, 55 kW

2

-

35000

... More
415V, 75 kW

6

-

75000

... More
Supply and installation of Cable Route markers

-

-

-

... More
Supply and fixing of Cable Route markers (30m interval) for HT Cable (11kV grade), CI material, 150mm Dia. Round with 5mm-6mm thickness, two holes for mounting, 3mm embossed lettering as appropriate, bolted/welded to 35mm x 35mm x 6mm angle iron, 600mm long and fixing the same in ground, including painting with all accessories all civil works, labour and materials complete as required and as per directions of Engineer-In-Charge.

50

-

990

... More
Supply and fixing of Cable Route markers (30m interval) for LT Cable (415V grade), CI material, 150mm Dia. Round with 5mm-6mm thickness, two holes for mounting, 3mm embossed lettering as appropriate, bolted/welded to 35mm x 35mm x 6mm angle iron, 600mm long and fixing the same in ground, including painting with all accessories all civil works, labour and materials complete as required and as per directions of Engineer-In-Charge.

50

-

990

... More
Supply and fixing of Cable Route markers (30m interval) for Control Cable, CI material, 150mm Dia. Round with 5mm-6mm thickness, two holes for mounting, 3mm embossed lettering as appropriate, bolted/welded to 35mm x 35mm x 6mm angle iron, 600mm long and fixing the same in ground, including painting with all accessories all civil works, labour and materials complete as required and as per directions of Engineer-In-Charge.

50

-

990

... More
Earthing System

-

-

-

... More
Supply, installation, testing & Commissioning for complete earthing, earth electrodes/ pit, earth main ring, earthing of electrical equipment, instrument panels, field instruments, with heavy duty perforated GI pipe electrode / Copper Plate Electrode, providing suitable earth bus for interconnection, SS nut bolts to be used for Copper earthing and clamps of the GI earthing which are operated on regular basis i.e. clamp connections at top, providing a mixture of salt & charcoal, making RCC/ Brick earth pit chamber and associated civil works as per standard Drg. etc. all complete as per specification & direction of Site-In-charge. Item also includes Supply and fixing of Earth resistance display board of size 450 X 300 mm with 3mm thick Aluminium Composite Material (ACM)/ Aluminium Composite Panel (ACP) bolted to 25 X 25 X 5 mm (with 2 bolts MS angle section, 60 cm long (minmum 200 mm embedded in ground). The rate shall also include supply and pasting of UV resistant vinyl sticker having details as per Site-in-charge.

-

-

-

... More
Earth Pits- Earth electrode with following sizes: 100 mm dia, 3.8 M long heavy duty perforated GI pipe electrode (Galvanisation is 610 gms/sq. mtr or as per IS-4759/ISO 1461.) as per IS:3043

120

-

35500

... More
Earth Pits- Copper plate Electrode (600 mm x 600 mm x 3 mm) with GI pipe electrode 50mm dia for Instrument Panel.

15

-

39800

... More
Supply & drawing/laying, jointing, connecting, testing and commissioning of Hot Dip Galvanized (Galvanisation is 610 gms/sq. mtr. or as per IS-4759/ISO 1461) earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following sizes as per direction of Site in-Charge.

-

-

-

... More
GI Strip (75X6) mm

1000

-

601

... More
GI Strip (50X6) mm

6500

-

439

... More
GI Strip (25X6) mm

600

-

275

... More
GI Strip (25X3) mm

2500

-

174

... More
Copper Strip (35X6) mm

250

-

2462

... More
Copper Strip (25X3) mm

700

-

1222.5

... More
Supply, & Installation of GI wire / rope 10 Sq mm all balance earthing material etc. as per the specification.

500

-

210

... More
Supply & Installation of GI wire / rope 25 Sq mm all balance earthing material etc. as per the specification.

500

-

385

... More
Supply, Installation & Laying, testing & commissioning of 8 SWG GI wire rope including nut bolt, washer,lugs and all balance earthing material as per the specification.

150

-

70

... More
Supply, Installation & Laying of 1C x 150 mm² PVC Insulated Cable

750

-

717

... More
Supply, Installation & Laying of 25mm square copper strip/braided flexible cable

250

-

750

... More
Supply, Installation & Laying of Flexible copper cable PVC insulated of 16sqmm for connecting the earth grid/earth strip with lugs at one end and with the crocodile clip i/c cost of 1 no. crocodile clip - For cable upto 2.5M in length.

32

-

2320

... More
Supply & laying / fixing of PVC insulated AL/Cu conductor Green cable for equipment earthing of 1Cx25 mm2 PVC (Al) cable

100

-

238.5

... More
Supply & laying / fixing 1C x6 sq mm green colur copper flexible cable for earthing of fittings

6000

-

130

... More
Supply & laying / fixing 1C x2.5 sq mm green colur copper flexible cable for earthing of fittings

18000

-

70

... More
Supply, erection and commissioning of 16 Ways Cu. Earthing Plate (busbar) -THICKNESS 12MM, LENGTH 1000MM

12

-

11184

... More
Supply, erection and commissioning of 16 Ways GI. Earthing Plate (busbar) - THICKNESS 12MM, LENGTH 1000MM

6

-

11184

... More
Supply, erection and commissioning of 8 Ways GI. Earthing Plate (busbar)- THICKNESS 12MM, LENGTH 1000MM

15

-

11184

... More
LIGHTNING PROTECTION SYSTEM

-

-

-

... More
Study & Designing of Lightning Protection System as per IEC 62305 and risk analysis for plant & non-plant buildings, tanks, sheds, bays, switchyard, etc.

1

-

484500

... More
Supply & laying, jointing, connecting, testing and commissioning of Hot Dip Galvanized (Galvanisation is 610 gms/sq. mtr. or as per IS-4759/ISO 1461) earth strip/copper strip/GI wire as horizontal and down conductor for Lightning protection system to be laid under or aboveground, on wall/ on RCC column/ steel structure/ curb/ roof including jointing by welding, connecting to equipments, painting to welded portion by black bitumen paint, complete as per specification for the following sizes as per direction of Site in-Charge. The rates shall be inclusive of hardware required for clamping of earth strip, jointing the strips, test link etc. Cost of insulators for the support of the system as per direction of Site In-Charge is included. As per IEC 62305.

-

-

-

... More
GI strip down conductor of 50 x 6 mm thick on parapet or surface of wall for lightning conductor complete with joints and other accessories as required.(for horizental /vertical run).

3000

-

507

... More
GI strip down conductor of 35 x 6 mm thick on parapet or surface of wall for lightning conductor complete with joints and other accessories as required.(for horizental /vertical run).

1800

-

329.5

... More
GI strip down conductor of 25 x 3 mm thick on parapet or surface of wall for lightning conductor complete with joints and other accessories as required.(for horizental /vertical run).

1000

-

205.5

... More
Supply, Installation, testing & commissioning of test link box for ligtning protection (for connection of each down conductor to earth pit) complete with other accessories as required.

77

-

5458

... More
Supply, Installation, testing & commissioning of 35 x 6 strip fixing saddles for ligtning protection complete with other accessories as required.

925

-

517

... More
Supply, Installation, testing & commissioning of square tape clamp for ligtning protection complete with other accessories as required.

77

-

643

... More
Supply, Installation, testing & commissioning of lightning conductor finial made of 25 mm dia 1800 mm long GI tube having single prong at top with 85 mm dia 3 mm thick GI base plate including holes etc. complete as required.

40

-

4875

... More
Supply & installation of 1000mm long, 20 dia. GI air termination rod (lightning rod) with all fixing material, accessories.

35

-

3210

... More
SOLAR SYSTEMS

-

-

-

... More
Design,Supply, installation of Solar roof top PV system including SPV Module, Power Conditioning Unit (PCU), Module Mounting Structure, Multi-function Energy meter, Lightning Arrester, Remote Monitoring System, Cables, All materials required for civil construction, all other Misc. required Equipments/materials (other than specified above) etc and as per attached specification for solar PV system including freight, loading / unloading, handling etc. all complete. Note:- 1) Qty. may very depending on roof top area avelable. Bidder to Quote per KWp rate for the same. 2) Tentative location of rooftop area of Admin Building. Transporatation to erection site, unpacking, checking, inspection, Installation in position,integration, testing and commisioning of grid inetractive roof top solar system along with all required material, like solar panels,cables,Cable trays,earthing and lightning protection,control panels,cable laying,hardwares ,fixing arrangement,steel materials,glanding and termination of cables etc complete with all required materials tools and tackles,testing instruments etc and as per attached specification and direction-of site-charge.

10

-

125250

... More
Charges for preparation of Drawings, SLD, Wiring Diagram for the HT Panel, Transformer, PMCC, Panels, Cables, JBs, DBs & Generator, etc., obtaining drawing approval, arranging for inspection, getting safety certificate of complete installation from CEA authorities/Statuary authority for energisation of HT Panel, Transformer, PMCC room & Generator, etc. The contractor shall give 5 sets of approved as built drawings. Note: a) The statutory payment to be made to the CEA authorities will be reimbursed at actual on submission of the original receipt to the owner OR The statutory payment shall be made by IOCL. b) The job also includes all liasoning to be carried out with State Electricity Board authorities for obtaining necessary approval for successful commissioning of the facilities.

1

-

600000

... More
ANCHOR FASTENERS : Providing & fixing anchor fasteners of approved make like HILTI and any of size on the RCC slab, beam, columns etc. at any height including drilling the holes using drilling machine / tools having carbide tips, scaffolding (If required) for fixing the fasteners and its bolt as per the drawing or as directed by Engineer in charge with all labour, materials, tools and tackles.

-

-

-

... More
Up to 1/4" BSW x 12 mm dia.

150

-

240

... More
Between 1/4" BSW x 12 mm to 3/8" BSW x 25 mm dia.

150

-

270

... More
RCC TRENCH COVER: Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge

300

-

3510

... More
CABLE JOINTING Cable Jointing : Providing straight through joint of following 1.1 KV grade XLPE insulated armoured cable with M-Seal make jointing kit, and other jointing material, etc. all complete including supply of all materials as per specification & direction of Engineer In-charge.

-

-

-

... More
i) 2 Core x 1.5 sq. mm.

5

-

1509.37

... More
ii) 2 Core x 2.5 sq. mm.

5

-

1509.37

... More
iii) 2 Core x 4 sq. mm

5

-

1509.37

... More
iv) 2 Core x 6 sq. mm

5

-

1509.37

... More
v) 2 Core x 16 sq. mm

5

-

1509.37

... More
vi) 3 Core x 1.5 sq. mm.

5

-

1615.51

... More
vii) 3 Core x 2.5 sq. mm

5

-

1615.51

... More
viii) 3 Core x 4 sq. mm

5

-

1615.51

... More
ix) 3 Core x 6 sq. mm

5

-

1615.51

... More
x) 3 Core x 16 sq. mm

5

-

1615.51

... More
xi) 4 Core x 2.5 sq. mm

5

-

1839.16

... More
xii) 4 Core x 6 sq. mm

5

-

1839.16

... More
xiii) 4 Core x 10 sq. mm

5

-

1839.16

... More
xiv) 4 Core x 16 sq. mm

5

-

1839.16

... More
xv) 4 Core x 25 sq. mm

5

-

1839.16

... More
xvi) 3.5 Core x 25 sq. mm

5

-

1615.51

... More
xvii) 3.5 Core x 35 sq. mm

5

-

1936.92

... More
xviii) 3.5 Core x 50 sq. mm

5

-

2212.17

... More
xix) 3.5 Core x 70 sq. mm

5

-

2361.61

... More
xx) 3.5 Core x 95 sq. mm

5

-

2602.47

... More
xxi) 3.5 Core x 120 sq. mm

5

-

2602.47

... More
xxii) 3.5 Core x 150 sq. mm

5

-

3348.54

... More
xxiii) 6 Core x 2.5 sq.mm

5

-

2145.92

... More
Re-laying corporation supplied cable complete as per specification

-

-

-

... More
i) 1.5 sq.mm to 2.5 sq.mm XLPE

250

-

39.44

... More
ii) 4 sq.mm to 10 sq.mm XLPE / AYFY

250

-

39.44

... More
iii) 16 to 35 sq.mm XLPE / AYFY

250

-

54.24

... More
iv) 50 sq.mm to70 sq.mm XLPE / AYFY

250

-

54.24

... More
v) 120 sq.mm XLPE / AYFY

250

-

54.24

... More
PART (B): CIVIL WORKS

-

-

-

... More
EARTHWORK a) The prices for all excavations are to include for removing and clearing away all shrubs, bushes, roots etc. b) The prices are also to include for all leveling and ramming foundation beds, trimming of sides and bottom grading to proper level as required. c) Removal and carrying shall include for all loading, unloading and handling as may be necessary and also all necessary means of transport (Mechanical or manual as required). d) The prices are also to include removal of water accumulated due to subsoil seepage, rains or from any kind of sources, either by pumping or by bailing or by any suitable method like well point dewatering etc. if reqd. No extra payment shall be made for dewatering. This also includes for draining out the pumped water to nearby available drainage system. e) Normally payment of earth work shall be made according to the sizes of PCC for trenches/ pits as contemplated in the working drawings. Extra due to widening or deepening of trenches / pits shall not be paid for except for the cases where water / acid proofing would be accepted as per working drawings in such case the mode of measurement shall be as per IS : 1200. f) Nothing extra shall be paid for sorting /screening of excavated materials to obtain good earth for filling. g) Nothing extra shall be paid on account of any lift for disposal of excavated materials. h) Where excavation are made in excess of the depth required, the contractor shall at his own expense fill up to the desired level with lean concrete of mix 1:5:10 (1 Cement: 5 Coarse sand: 10 Graded stone aggregate 40 mm nominal size.

-

-

-

... More
i) Rate shall include Royalty, Taxes, etc., levied by the local authorities, all transportation, loading and unloading, etc., and nothing extra will be paid on this account. j) Soft / loose soil also includes filled up earth / murrum. k) The filling for earth / murrum or sand shall be done in layers not exceeding 20 cm in thickness (consolidated) with Suitable means to achieve 95% dry density at Optimum Moisture Content corresponding to standard Proctor test compaction with vibroroller(8 to 10MT capacity) & vibro compactor in confined spaces. l) For other conditions please refer document.

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means including disposal of excavated earth within and outside site to unobjectionable place, disposed earth to be levelled and neatly dressed including all lead and lifts/depth. All kinds of Soil such as ordinary/hard soil, kankar, murrum, gravel, pebbles, bajri, removal of shrubs, uprooting the tree roots etc. and all types of material encountered in excavation including excavation of saturated soils, mud, sludge etc.

2500

-

182.22

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m

1500

-

220.1

... More
Supply & filling imported local earth (including royalty) of approved quality, in plot, trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth each deposited layer by ramming and watering. Item includes compaction using minium 15 ton capacity vibro-compactor with a adequate minimum of passes for earth work in under optimum moisture conditions to give at least 95% of the maximum dry density of the material. Note: a) Tenderer to note that initial & final level survey shall be undertaken jointly by the Contractor &/or representatives with IOC Site Engineer. b) Tenderers to note that approval from IOCL shall be obtained for the imported earth & quarry used for mass filling & necessary test reports from a Govt Engg Colleges/Universities or NABL acredited labs (As approved by IOCL/PMC Engineer) have to be submiited for the parameters specified by IOCL prior to undertaking filling in the site. c) Item rate is inclusive of applicable Royalty for the imported earth, charges for Specific approval to be obtained from concerned Statutory Authorities & Necessary Royalty receipts/ NOC to be submitted by the Contractor. d) Net quantity of compacted earth shall be paid & no compensation whatsoever on account of subsidence of soil etc shall be permitted. e) No extra cost shall be payable by IOCL on account of payment of any statutory fees and compliances sought by statuory authorities from tenderer both within & outisde the premises.

300

-

705.02

... More
Supplying and filling in plinth with local coarse sand within grading zone III within specified grading zone of fine aggregates specified Tender specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.

350

-

2124.69

... More
HARD-CORE SOLING: Providing and laying dry stone hard rubble/boulder soling of required thickness under floor, ramps, walls, foundation, trenches, etc. & for similar situations at plinth level/ below plinth level including watering, ramming, Bliding, and well consolidating, laying in regular lines , levels, interstices, filled with smaller stones /chips of appropriate size [with material confirming to grade-I (size 75 mm to .075 mm)] and sand consolidated with copious watering as specified & finished to the required level, complete as per specification compacting with vibratory power & direction of by site engineer. The soling shall be laid and hand packed true to grade and section and these shall be often checked by borning rods,temple boards,fish line,etc..The grades sections etc.of soling shall correspond to those of the surfacing coming thereon.The soling thus laid shall be finished by knocking out projecting stones and filling depressions by chips to reach up to the grade & camber. (Payment shall be made of finished compacted thickness of hard core)

50

-

2286.32

... More
CONCRETE WORK/ REINFORCED CONCRETE WORK

-

-

-

... More
a) The prices for concrete in beds and slabs are to include for laying on any type of sub grade, laying to falls, or cambers and for preparing surfaces to receive concrete. b) All concrete surfaces shall be finished to a fair face to give a smooth and even surface. Nothing extra shall be paid on this account. c) The prices are to include leaving pockets, cut outs and holes and to provide wooden boxes or any other suitable arrangements in RCC for bolt holes in slab, beams, walls, foundation of equipment's etc. as per approved working drawing. (Nothing extra shall be paid on this account) d) No deduction in RCC quantity shall be made for pockets and nothing extra shall be paid for providing pockets as mentioned in para 'C' above. e) Measurement of opening in concrete work/RCC work: For measurement of openings in concrete work / RCC works, shall be as per IS: 1200 Part-III. f) All pocket holes are to be properly covered by suitable means so that dirt, rain water etc. etc., should not enter the pockets/holes etc. (Nothing extra shall be paid on this account.) g) Threads of bolts etc. which have already been fixed in the pockets are to be greased and polythene sheet properly covered with gunny bags to protect it from damages from all sources. (Nothing extra shall be paid on this account.) h) The prices shall include for all rebating, trotting, chamfering weathering, molding etc. to accord with the details shown on the approved working drawings. i) Nothing extra shall be paid for any intricate concrete work for foundations of equipment's and machinery (dynamic/static), RCC wall and other superstructure works or any delay in concreting in small and thin sections in PCC or RCC works.

-

-

-

... More
j) The prices for concrete are to include for hoisting and / or lowering to any height and/or depth required and in any type of form work, packing around reinforcement where required and finishing the surfaces, to fair and even surface k) The prices shall include working up or hacking of concrete surface for providing keys for further concrete work and shall also include all plane, rebated or grooved constructional and other joints. l) The design mixes of all controlled concrete of various grades shall be established by the contractor on the basis of weigh batching, at the beginning of work. In all concrete / RCC work graded coarse aggregate shall be used. Any concrete work with honey comb shall be rejected and the work has to be redone by the contractor at his own cost. m) Concrete admixtures for workability if necessary, may be used in RCC if decided by Engineer-in-charge. No extra payment for mixing etc, shall be made on this account. n) Machine and equipment foundations shall mean all foundations including pedestals of vessels, towers, pumps, compressor motors, or any other equipment or machinery (both static and dynamic), pipe supports, etc. and the like. o) The prices are also to include the removal of water caused by rains/seepage etc. either pumping or by bailing out or by special means like well point dewatering etc. that may accumulate in the trenches and foundation pits etc. p) Approved brand of 43 grade cement shall be used for preparing design mix & cement shall be tested as per relevant IS Codes.The prices are to include the supply of cement by the contractor. q) Anti shrinkage compound used in grouting shall be paid separately. r) The source of supply for sand and stone chips shall be approved by IOCL.

-

-

-

... More
Following additional points to be noted for Ready Mix Concrete(RMC) a) Ready mix concrete (RMC) of approved vendor at the site of casting including coordinating with Engineer-in-charge, prior to casting, making all arrangement to unload the concrete so as to ensure that RMC is not detained for unloading, placing the concrete at site, vibrating, taking concrete cubes, testing, curing the concrete etc. complete in relevant items. b) Necessary schedule will have to be submitted by agency 3 days in advance so that proper coordination with Engineer-in-charge is done. c) It shall be ensured that shuttering done by contractor shall be adequate to withstand pumping pressure. d) Any loss of material shall be contractor’s responsibility. e) Submission of test results at RMC mixing plant site as well as casting site shall be contractors responsibility f) Desired design mix shall be got approved from Engineer-in charge before placing order for RMC. g) Any toll taxes applicable to be borne by the contractor. h) Any other taxes as levied by Govt. from time to time shall be deemed to be inclusive in the contract. i) Approved brand of 43 grade cement shall be used for preparing RMC & Cement shall be tested as per relevant IS Codes. Cement supply shall be in contractor’s scope.

-

-

-

... More
PLAIN CEMENT CONCRETE:

-

-

-

... More
Providing and laying cement concrete in foundation, footings and base for columns/walls including proportioning, mixing in mechanical mixer, laying vibration by means of mechanical vibrators, curing etc. complete including the cost of shuttering:-

-

-

-

... More
Concrete of mix 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

50

-

6802.74

... More
Concrete of mix 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

150

-

6272.13

... More
REINFORCED CEMENT CONCRETE

-

-

-

... More
IN FOUNDATION & PLINTH: Providing and laying in position, machine batched & machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement. Including admixtures in recommended proportions as per IS 9109 to accelerate, retard setting of concrete,improve workability without impairing strength and durability as per direction of Engineer-in-charge -- M-25 grade reinforced cement concrete UP TO PLINTH LEVEL Note :- a. Minimum Cement content considered in this item is @400 kg/cum and accordingly design mix to be done. Less cement used as per design mix (if any) will be recoverable separately. No extra payment against extra cement if used shall be payable. b. Batch mixing plant of capacity to be approved by Site Engineer for the works to be installed by the Contractor at site along with required NOCs from concerned Authorities. Alternatively, Contractor shall also be permitted to use RMC (if available) at no extra cost to IOC & after obtaining prior approval from Engineer In-Charge. c. For small quantities (up to 5 cum per day), mixing & placing of concrete of M25 (1:1:2) using mechanical mixer shall be permitted with the prior approval of IOC. d. Hacking of exposed surface of green concrete (wherever applicable) as Key to plaster shall be done at no extra cost to IOC.

375

-

8013.96

... More
SHUTTERING & CENTERING

-

-

-

... More
Centering and shuttering including strutting, propping etc. with suitable materials as per Tender conditions & specifications and removal of form for: -

-

-

-

... More
Foundations,footings,bases of columns, etc. for mass concrete RCC

490

-

285.45

... More
Columns, Pillars, Piers, Abutments, Posts and Struts.

180

-

735.23

... More
Providing grouting in pockets/ bases etc (As per Technical specification), cost of grouting, including supply of materials shall be covered in the unit rates. Rates shall include cost of labor, supervision, deployment of tools & tackles, consumables, materials and other associated arrangements required to execute all the related activities. Grouting using Free flow non shrinkable grout material CONBEXTRA GP-2 or approved equivalent etc

5

-

10860.04

... More
REINFORCEMENT & EMBEDMENTS

-

-

-

... More
a) Wastage in cutting will not be paid Only steel actually fixed in position will be paid by the linear measurement i/c hooks, chairs, dowels and laps. Only authorized hooks and laps approved in bar bending schedule shall be paid. Lapping of bars will be allowed only where the required bar length exceeds the standard lengths available unless otherwise approved. All other laps provided unless otherwise specified in the drawings shall not be measured and paid for. Weight of binding wire shall not be measured for payment. The prices are to include for the supply of all Reinforcement & Embedment at site by the Contractor. b) Reinforcement are to be tack welded in addition to binding by 18 SWG annealed wire wherever necessary to impart fixity. Bars of 28 mm dia & above shall also be provided with stitch weld in additions to binding with annealed iron wire and nothing extra will be paid for stitch welding. Stitch welding shall be done as per IS specifications. No extra claim shall be entertained on this account. c) Supplying, cutting, bending, hoisting, placing in position with proper precast concrete block cover and binding with 18 SWG annealed wire, high yield strength deformed bars as per IS: 1786 for all R.C.C works including all necessary handling at all heights and depths complete in all respects and as per direction of the Engineer-in-Charge.

-

-

-

... More
Thermo Mechanically Treated Bars Fe- 500D grade or better, Conforming to IS1786

55000

-

83.68

... More
Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,with suitable anchorage all conforming to relevant Indian Standards and as approved by Engineer-in-charge :

2500

-

133.11

... More
STRUCTURAL STEEL

-

-

-

... More
Supplying, transporting, de-rusting, fabricating, erecting, hoisting and fixing in position with necessary welding and/or bolting with MS bolts conforming to property class 4.6 or higher of I.S:1367 at all height as per approved fabrication drawings of all types of structural steel work in rolled steel joints, channels, angles, tees, flats, plates, lattice members built up / compound sections in columns, portals, girders, beams, bracings, trusses, purlins, rafters, staircase, steps, hand-railings, walkway, cat ladder with cages, toe plates, side walling, trestles, Conveyor gantries grating, chequred plate etc. including gusset plates, anchor plates etc., including site and shop fasteners, riveting, bolting, welding at shop or work site at all heights etc. & including applying approved coats of primers, undercoat and finish painting as per Technical specification. Complete as per drawing and direction of Owner / Consultant. (All material supply is in contractor’s scope including paints ) Providing and applying Anticorrosive treatment to structural steel surface as per below specifications. a) Surface preparation by shot blasting conforming to SA 2.5 b) Primer coat of INORGANIC ZINC ETHYL SILICATE (DFT 65 – 75 micron) c) Intermediate coat of TWO PACK EPOXY-POLYAMIDE MIO UNDERCOAT (DFT 100 – 125 micron) d) Final coat of TWO PACK ALIPHATIC POLYURETHANE (DFT40-50 micron) Total DFT shall be min 215 micron. Final paint shades shall be as approved by IOCL. Payment will be on the basis of weight of structural steel provided.

30000

-

101.96

... More
Steel work in built up tubular-Hot finished welded type tubes (round, square or rectangular hollow tubes etc) trusses etc. including cutting,hoisting fixing in position including welded and bolted with special shaped washers etc and applying a priming coat of approved steel primer, undercoat and finish painting as per Technical specification . Complete as per drawing and direction of Owner / Consultant. (All material supply is in contractor’s scope including paints ) Providing and applying Anticorrosive treatment to structural steel surface as per below specifications. a) Surface preparation by shot blasting conforming to SA 2.5 b) Primer coat of INORGANIC ZINC ETHYL SILICATE (DFT 65 – 75 micron) c) Intermediate coat of TWO PACK EPOXY-POLYAMIDE MIO UNDERCOAT (DFT 100 – 125 micron) d) Final coat of TWO PACK ALIPHATIC POLYURETHANE (DFT40-50 micron) Total DFT shall be min 215 micron. Final paint shades shall be as approved by IOCL. Payment will be on the basis of weight of structural steel provided.

2000

-

143.74

... More
BRICK WORK/ FINISHING/ PAINTING

-

-

-

... More
Providing and laying Brick work with bricks of minimum class designation 50 as per CPWD Specification unless otherwise mentioned including scaffolding. The rates are to include for work at any height / depth and for all necessary scaffolding, support arrangements etc. as required.

-

-

-

... More
Brick work with class designation 5.0 bricks in cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH

100

-

6058.35

... More
Brick work with class designation 5.0 bricks in cement mortar 1:4 (1 cement : 4 coarse sand) in superstructure ABOVE PLINTH AND UP TO FLOOR V LEVEL

25

-

7494.35

... More
FINISHING:

-

-

-

... More
Providing and laying cement plaster on surfaces in one/two coats including curing etc. a) The prices are to include for work at any height / depth and for all necessary scaffolding etc. as required. b) The prices shall also include for making to form key for plaster and for all work in narrow width formed angles, chamfered external angles and for making good the faces. c) Plastering shall be measured in sq. meter area of the surface to be plastered, as per IS: 1200 (Part XII). The rate shall include erecting and removal of scaffolding all labour, all materials, equipment, plants, tools and all incidental expenses to complete plastering, pointing, rubbing out joints, cleaning, wetting, filling with cement mortar, troweling etc. and making of drip moulds, grooves, vattas, bands etc. including curing. d) The prices are to include the supply of cement at site by the contractor. e) Sand used for plastering shall be from approved sources. f) Hacking of RCC surfaces shall be done when the concrete is green in order to provide key to plaster. g) Plastering shall be done using 1 Kg of water proofing compound to every bag of cement used. h) The above cost includes the rates for making Plaster Band, Elevation Plaster Treatment & etc in any shape & size in plaster or as directed by EIC.

-

-

-

... More
i) 12mm Cement plaster of mix 1:4 (1 cement: 4 coarse sand)

250

-

276.72

... More
ii) 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarses and) and a top layer 6mm thick cement plaster 1:3 (1 cement: 3 coarse sand) finished rough with sponge.

750

-

400.13

... More
Providing neat cement punning

500

-

62.89

... More
Finishing walls with Acrylic Smooth exterior paint with Two or more coat applied @ 1.67 ltr/10 sqm over & including base coat of water proofing cement paint applied @ 2.20kg/10 sqm to achieve required shade and colour complete as specified by IOCL.

500

-

165.04

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty

-

-

-

... More
150 mm dia. R.C.C. pipe

100

-

463.56

... More
300 mm dia. R.C.C. pipe

100

-

865.45

... More
600 mm dia. R.C.C. pipe

50

-

1952.41

... More
PART (C) : DEMOLITION & DISMANTLING

-

-

-

... More
Dismantling & Erection of one existing 30 mtr High Mast Tower along with all accessories, fixtures, wires/cables, JB etc.

1

-

152000

... More
Dismantling of wall in existing PMCC room

150

-

1500

... More
Disconnecting and relaying Corporation supplied cable complete as per specification

500

-

150

... More
Dismantling of existing 1000kVA Indoor Transformer along with all accessories

1

-

135000

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars & disposal of unserviceable material outside site to an unobjectionable place as/ direction of Engineer-in-charge

20

-

2539.98

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material outside premises at an unobjectionable place as per direction of Engineer-in-charge.

-

-

-

... More
i) 1:3:6 or richer mix (i/c equivalent design mix)

50

-

1741.07

... More
ii) 1:4:8 or leaner mix (i/c equivalent design mix)

50

-

1075.03

... More
Dismantling Steel work in single sections including dismembering and stacking within premises

-

-

-

... More
i) R.S Joists

500

-

2.46

... More
ii) Channels, angles, tees and flats etc

498.9

-

1.71

... More
Dismantling Steel work in built up sections in angles, tees, flats channels etc. including all gusset plates, bolts nuts, cutting rivets welding etc. including dismembering and stacking within premises

500

-

4.15

... More
Dismantling manually/by mechanical means including stacking of serviceable material & disposal of unserviceable material outside site at unobjectionable place as per direction of Engineer-in-charge :

-

-

-

... More
i) Water bound macadam road

150

-

156.33

... More
ii) Bituminous road

150

-

307.28

... More
DISMANTLING Dismantling of following electrical fittings / fixtures with all leads and lifts.

-

-

-

... More
i) Electrical cables of all sizes from under / above ground position

500

-

29.05

... More
ii) DPS board all types with/ without stand

5

-

202.6

... More
iii) 5 to 15A switches/MCBs/plugs

5

-

202.6

... More
iv) 32/63/100A DP/TPN switches/ MCCBs /MCBs

5

-

202.6

... More
v) Flourescent tube light fittings of all sizes

5

-

116.22

... More
vi) Starters (all types ) of power pumps

5

-

232.41

... More
vii) Power pump up to 5 HP

2

-

8194.32

... More
viii) Power pump above 5 HP up to25 HP HP

2

-

12959.85

... More
Dismantling of light poles

10

-

2008.48



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.