Guwahati Smart City Limited Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Guwahati Smart City Limited - GSCL Tender

Eprocure
Opening Date20 Dec 2021
Closing Date11 Jan 2022
Tender Amount₹ 14,32,30,127 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

950

-

-

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

200

-

-

... More
Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable materials: Beyond 30 cm girth upto and including 60 cm girth

4

-

-

... More
Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable materials: Beyond 60 cm girth upto and including 120 cm girth

8

-

-

... More
Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable materials: Beyond 120 cm girth upto and including 240 cm girth

3

-

-

... More
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%

120

-

-

... More
Diluting and injecting chemical emulsion for anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration (excluding the cost of chemical emulsion)

135

-

-

... More
Diluting and injecting chemical emulsion for anti-termite treatment of soil under floors using chemical emulsion @ 5 litre per Sqm of floor area : With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration (excluding the cost of chemical emulsion)

400

-

-

... More
Extra for levelling & neatly dressing of disposed soil completely within the project campus as directed by Engineer-in-charge.

2500

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)

46

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

102

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 Cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 20 mm nominal size derived from natural sources)

125

-

-

... More
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)

5

-

-

... More
Providing and laying cement concrete in kerbs, steps and the like at all levels excluding the cost of centering, shuttering and finishing. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

5

-

-

... More
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.

37

-

-

... More
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.

20

-

-

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.

85

-

-

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for all works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum Note: 1) LVL +0.00 indicated in building plan drawings shall be reckoned as the plinth level for all the structural elements in the Lower Ground Floor) 2) Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

550

-

-

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for all works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

1150

-

-

... More
Extra for using extra cement in the items of design mix over and above the specified cement content therein.

610

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all levels. Thermo-Mechanically Treated bars of grade Fe-500D or more.

220000

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete

600

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1600

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies, access platform, and cast in situ Shelves

2275

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers

3300

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts (Rectangular / Square sections)

1400

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts (Circular sections)

360

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Stairs (excluding landings)

385

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Vertical and horizontal fins individually or forming box louvers band, facias, gutters (side & slab) and eaves boards

400

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like (bands & sills in AAC items will be paid under subhead Masonry Works)

20

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls - Under 20 cm wide

550

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls - Above 20 cm wide

65

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like

20

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges at all levels

52

-

-

... More
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.6 m, for suspended floors, roofs, landing and beams at a height 6.5 m to 7.0 m above (Plan area to be measured)

120

-

-

... More
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.6 m, for suspended floors, roofs, landing and beams at a height upto 4.6 m above (Plan area to be measured)

215

-

-

... More
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.6 m, for auditorum seating steps at an average height 5.6 m to 6.0 m above (mean above 3.6 m shall be reckoned for the average height) (Plan area to be measured)

210

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand)

90

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)

95

-

-

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in Cement mortar 1:4 (1 cement :4 coarse sand) including providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.

525

-

-

... More
Providing and laying autoclaved aerated cement blocks masonry with 125mm/ 150MM/ 225mm/ 250 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level and studs/ struts on door-side end with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

425

-

-

... More
RCC Band/Lintels/studs including Chajja in AAC & Brick masonry with reinforced cement concrete of mix 1:1.5:3 (1 cment : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 12.5mm - 20mm nominal size derived from natural sources)

70

-

-

... More
Reinforcement for RCC bands/studs in AAC masonry including straightening, cutting, bending, placing in position and binding all complete at all levels in Mild steel and Medium Tensile steel bars (RCC lintels & chajjas including reinforcement bars over openings will be paid under subhead "Reinforced Cement Concrete Work)

3500

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for RCC sill band, bond band & studs/ struts in AAC masonry works

140

-

-

... More
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand)

40

-

-

... More
Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like - in Cement mortar 1:6 (1 cement : 6 coarse sand)

75

-

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red - Area of slab over 0.50 sqm

41

-

-

... More
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge - Granite work

87

-

-

... More
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.

87

-

-

... More
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

23

-

-

... More
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth - Granite Stone of approved shade

2

-

-

... More
Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete - 8mm thick Rajnagar plain white marble/ Udaipur green marble/ Zebra black marble

95

-

-

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C, fixied with adjustable lugs with split end tail to each jamb

190

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters including providing mechanical device chain and crank operation for operating the rolling shutter complete as directed by Engineer-in-Charge 80x1.20 mm M.S. laths with 1.20 mm thick top cover

21

-

-

... More
Providing and fixing ball bearing for rolling shutters.

8

-

-

... More
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured).

3

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters and including providing decorative veneering on one face of the shutter as per design approved by Engineer-in-Charge 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

78

-

-

... More
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick

78

-

-

... More
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).

78

-

-

... More
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or square

29

-

-

... More
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).

30

-

-

... More
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 2nd class teak wood - 50x20 mm

200

-

-

... More
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 50 x 100 mm

150

-

-

... More
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick

46

-

-

... More
Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : 75x50x2.50 mm

90

-

-

... More
Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ±. 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.

18

-

-

... More
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Casement window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm upto 3.00 sqm).

35

-

-

... More
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqm upto 5.00 sqm).

45

-

-

... More
Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension.

56

-

-

... More
Providing and fixing glazing in aluminium/uPVC door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge: With float glass panes of 4 mm thickness (weight not less than 10 kg/sqm)

56

-

-

... More
Providing and fixing glazing in aluminium/uPVC door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge: With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)

80

-

-

... More
Providing and fixing glazing in aluminium/uPVC door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge: With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)

18

-

-

... More
Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).

13

-

-

... More
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width

400

-

-

... More
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

38

-

-

... More
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

20

-

-

... More
Providing and fixing chromium plated brass handles with necessary screws etc. complete - 125 mm

54

-

-

... More
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm

22

-

-

... More
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm

30

-

-

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm

60

-

-

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10 mm

60

-

-

... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm

60

-

-

... More
Providing and fixing 18 mm thick, 150 mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density grade I, IS : 3087 marked, including top cover of 6 mm commercial ply wood conforming to IS: 303 BWR grade, 25mm dia chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete, including fixing with 25x3 mm M.S. flat 10 cm long fixed to pelmet with hollock wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete.

30

-

-

... More
Providing and fixing teak wood lipping of size 25x3 mm in pelmet.

32

-

-

... More
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness

4

-

-

... More
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

120

-

-

... More
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick

62

-

-

... More
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick

150

-

-

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick

375

-

-

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

65

-

-

... More
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed vitrified floor tiles polished finish of size 600 x 600 mm

325

-

-

... More
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed vitrified floor tiles polished finish of size 800 x 800 mm

230

-

-

... More
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size 600 x 600 mm

68

-

-

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm

62

-

-

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 800x800 mm

15

-

-

... More
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more as per drawing (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.

50

-

-

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

410

-

-

... More
Providing and fixing glazed screen printed border tile 75mm wide having thickness 5mm, of approved quality & make, in all shades, design and prints, in dado, over 12mm thick bed of cement mortar 1:3 (1 Cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3 kg/sqm including pointing with white cement mixed with pigment of matching shade, all complete as approved by Engineer - in - Charge

32

-

-

... More
Providing and laying flamed finish Granite stone flooring with skirting in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

320

-

-

... More
Providing and laying Polished Granite stone flooring with skirting in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red

570

-

-

... More
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Udaipur green marble

105

-

-

... More
Extra for pre finished nosing/moulding to treads of steps/skirting of kota/marble/granite stone.

900

-

-

... More
Extra for kota/marble/granite stone flooring in treads of steps and risers using single length up to 2.00 metre.

160

-

-

... More
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).

138

-

-

... More
Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge:

80

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

1450

-

-

... More
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tubes

200

-

-

... More
Providing and fixing bolts including nuts and washers complete.

550

-

-

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes

23500

-

-

... More
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

1750

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete

200

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

2800

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

500

-

-

... More
Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). 0.71 mm, Aluminium Color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm.

1255

-

-

... More
Providing and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)] For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/ tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : Precoated/mill finish aluminium Flashings/ Aprons (Upto 600 mm)

70

-

-

... More
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.

515

-

-

... More
Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/mK.

-

-

-

... More
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ? 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6)

116

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, Single socketed pipes - 110mm diameter

125

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler - 110mm

10

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.50 - 110mm

30

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee without door - 110x110x110mm

3

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (plain) - 110mm

25

-

-

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm

110

-

-

... More
Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms.

25

-

-

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

25

-

-

... More
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).

130

-

-

... More
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)

28

-

-

... More
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured.

325

-

-

... More
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) 78, solar reflection 0.70 and initial emittance 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.

325

-

-

... More
Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer's specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R- 2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

1500

-

-

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm

570

-

-

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm.

20

-

-

... More
Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively), VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer's specifications and as approved by Engineer-in-Charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., washing with water all complete. The contractor shall give guarantee for the perfomance of SRI and also the durabitity of coating, all complete as per direction of Engineer-in-Charge.

23

-

-

... More
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.

165

-

-

... More
(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.

-

-

-

... More
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.

2100

-

-

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:

215

-

-

... More
(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:

-

-

-

... More
(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.

-

-

-

... More
(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double Sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.

-

-

-

... More
(d) Providing and fixing in position flashings of solid aluminium Sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.

-

-

-

... More
(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.

-

-

-

... More
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.

-

-

-

... More
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately.

-

-

-

... More
The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/IEC 17025

-

-

-

... More
1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml

-

-

-

... More
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

215

-

-

... More
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.

3

-

-

... More
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

40

-

-

... More
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.

1650

-

-

... More
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)

6400

-

-

... More
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)

500

-

-

... More
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)

2250

-

-

... More
6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of Engineer-In-Charge.

400

-

-

... More
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

500

-

-

... More
18 mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band, 5cm wide

300

-

-

... More
White washing with lime to give an even shade : New work (three or more coats)

2250

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

4500

-

-

... More
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two or more coats on new work

6400

-

-

... More
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With ready mixed pink or grey primer on wood work hard and soft wood) having VOC content less than 50 grams/ litre

100

-

-

... More
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre

6400

-

-

... More
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm

450

-

-

... More
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.

1250

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture

500

-

-

... More
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.

1700

-

-

... More
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25

185

-

-

... More
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.

175

-

-

... More
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineerin- charge.

200

-

-

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).

35

-

-

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.

50

-

-

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.

1025

-

-

... More
Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge.

95

-

-

... More
Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Using grade 'A' sealing compound conforming to IS: 1834. - 12mm wide and 15cm deep

550

-

-

... More
Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of ail dirt, scales, oil, grease and other foreign material etc. and lining out complete. New work (Two or more coats)

50

-

-

... More
75 mm thick back filling for retaining water drainage including supplying of required materials and consolidation etc. complete with : Stone aggregate 20 mm nominal size

300

-

-

... More
Providing and laying gang saw cut 18 mm thick, mirror polished premoulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. With granite stone of area less than 0.50 sqm.

210

-

-

... More
Providing and erecting 3.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineerin-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work).

90

-

-

... More
Providing & making Gabion structure with Mechanically Woven Double Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012,MORTH Clause 2500, of required size, Mesh Type 10x12(D=100 mm with tolerance of ±2%), Zinic+10% Al alloy+PVC coated, Mesh wire diameter 2.7/3.7mm (ID/OD), mechanically edged/ selvedged with partitions at every 1m interval and shall have minimum 10 numbers of openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter 2.2/3.2mm(ID/OD), supplied @3% by weight of Gabion boxes, filled with boulders with least dimension of 200 mm, as per drawing, all complete as per directions of Engineerin-charge.

360

-

-

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe

100

-

-

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe

30

-

-

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 300 mm dia. R.C.C. pipe

20

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

20

-

-

... More
Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg

2

-

-

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

-

-

... More
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 450 mm dia RCC pipes.

20

-

-

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level: All types of soil - 300mm dia

90

-

-

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level: All types of soils - 300 mm dia

30

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia,conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge: 200 mm nominal size dia

90

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conformingto IS: 12818, including hire & labour charges, fittings & accessories etc.all complete, for all depths, as per direction of Engineer-in-charge: 200 mm nominal size dia

30

-

-

... More
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge.

5

-

-

... More
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.

36

-

-

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia

1

-

-

... More
Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete: 200 mm clamp

1

-

-

... More
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I): 200 mm dia

1

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.: External work - 65mm dia NB

100

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 65 mm nominal bore

1

-

-

... More
Providing and fixing gun metal non- return valve of approved quality (screwed end): 80 mm nominal bore

1

-

-

... More
Supplying & installation of KSB make submersible pump set directly coupled with 5 HP motor including supply of panel board duly wired made of 16/18 SWG sheet including fixing of the same in wall/floor on angle iron frame as per site conditions complete as per manufacturer's specifications and directions of Engineer-in-Charge

1

-

-

... More
Providing & fixing heavy duty PVC sheathed copper conductor 1100 volts grade cables with clamps complete in all respect: Control cable for low water level guard 2 core 2.5 Sq.mm.

120

-

-

... More
Providing & fixing heavy duty PVC sheathed copper conductor 1100 volts grade cables with clamps complete in all respect: Power cable 3 core 4 Sq.mm.

120

-

-

... More
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid

66

-

-

... More
Providing and fixing vitreous china wall hung water closet (European type) with C.P. bolts, nuts, CI chair, soft closing solid plastic seat cover with lid, CP brass hinges and rubber buffers, connected to existing Concealed Cistern with chrome finish front plate, 32mm dia flush pipe with clamp and rubber adapter joint, CP brass screws and washers and any other accessories complete including cutting and making good the walls and floors wherever required. (JAQUAR CNS-WHT-963SPP,JCS-WHT-2400S,JCP-CHR-2415)

2

-

-

... More
Providing and fixing vitreous china, wash basin with specially fabricated M.S. or CI brackets, 32mm CP brass waste of standard pattern, 32mm dia C.P. brass bottle trap and making connection to the waste pipe in wall with C.P wall flange and rubber adopter complete with required accessories including painting of brackets and cutting and making good the walls wherever required. Under counter (Jaquar make-CNS-WHT-705)

22

-

-

... More
Providing and fixing vitreous china, Urinal , 40mm CP brass waste of standard pattern, 40mm dia C.P. brass bottle trap and making connection to the soil pipe in wall with C.P wall flange and rubber adopter complete with required accessories including painting of brackets and cutting and making good the walls wherever required. With inbuilt Auto Urinal Flush

7

-

-

... More
Providing and fixing following Chrome Plated Fittings complete with required accessories including cutting and making good the walls wherever required to compete the work functionally and asthetically as directed by the consultnat: Shower Head (Jaquar make Model No-OHS-1787)

2

-

-

... More
Providing and fixing following Chrome Plated Fittings complete with required accessories including cutting and making good the walls wherever required to compete the work functionally and asthetically as directed by the consultnat: Bath spout(Jaquar make Model No-SPJ-37463)

2

-

-

... More
Providing and fixing following Chrome Plated Fittings complete with required accessories including cutting and making good the walls wherever required to compete the work functionally and asthetically as directed by the consultnat: Shower diverter(Jaquar ALD-CHR-065 N)

2

-

-

... More
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore

52

-

-

... More
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal dia

68

-

-

... More
Providing and fixing CP Brass Sink Cock of quality & make as approved by Engineer in charge. Sink Cock (only cold water) (Jaquar make Model No-CON-357KN)

2

-

-

... More
Providing and fixing CP Brass Pillar Cock of quality & make as approved by Engineer in charge. Pillar Cock (CON-CHR-011KN)

22

-

-

... More
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.

22

-

-

... More
Providing and fixing Waste Coupling for wash basin and sink (Jaquar make Model No-ALD-CHR-709)

22

-

-

... More
Providing and fixing Towel Rack 600mm long (Jaquar make Model No-ACN-1181S)

2

-

-

... More
Providing and fixing Towel ring (Jaquar make Model No-ACN-1121BN)

22

-

-

... More
Providing and fixing toilet paper holder : CP brass

68

-

-

... More
Providing and fixing Soap dish holder (Jaquar make Model No-ACN-1131N)

2

-

-

... More
Providing and fixing Robe hook( Jaquar make Model No-ACN-1191N

68

-

-

... More
Providing and fixing Grab bar (WAC-SAP-BR0600CS)

4

-

-

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board - 510x1040 mm bowl depth 250 mm

2

-

-

... More
Providing, jointing, testing and fixing UPVC Soil, Waste & Vent system conforming to IS : 13592 - Type B and UPVC fittings (moulded as well as fabricated) like bends, tees, Y-tees, crosses, boss connections, access pieces, saddle pieces, cleanouts, adaptors for connections to other materials, plugs, reducers, cowls, offSet and other specials. Jointing shall be done with pushfit EPDM ring jointing technique in general. Solvent cement joints may be provided for fittings and specials which are not manufactured with pushfit rubber joints. Pipes may be laid / fixed in sunken floors, under slung from ceiling. The pipes laid in sunken floor shall be encased with 75 mm thick cement concrete (1:2:4) all around. The installation shall be complete in all respects including cutting chases / holes in walls, slabs and making good the same as per specifications. (For Internal Toilet Only) 32mm dia

30

-

-

... More
Providing, jointing, testing and fixing UPVC Soil, Waste & Vent system conforming to IS : 13592 - Type B and UPVC fittings (moulded as well as fabricated) like bends, tees, Y-tees, crosses, boss connections, access pieces, saddle pieces, cleanouts, adaptors for connections to other materials, plugs, reducers, cowls, offSet and other specials. Jointing shall be done with pushfit EPDM ring jointing technique in general. Solvent cement joints may be provided for fittings and specials which are not manufactured with pushfit rubber joints. Pipes may be laid / fixed in sunken floors, under slung from ceiling. The pipes laid in sunken floor shall be encased with 75 mm thick cement concrete (1:2:4) all around. The installation shall be complete in all respects including cutting chases / holes in walls, slabs and making good the same as per specifications. (For Internal Toilet Only) 50mm dia

48

-

-

... More
Providing, jointing, testing and fixing UPVC Soil, Waste & Vent system conforming to IS : 13592 - Type B and UPVC fittings (moulded as well as fabricated) like bends, tees, Y-tees, crosses, boss connections, access pieces, saddle pieces, cleanouts, adaptors for connections to other materials, plugs, reducers, cowls, offSet and other specials. Jointing shall be done with pushfit EPDM ring jointing technique in general. Solvent cement joints may be provided for fittings and specials which are not manufactured with pushfit rubber joints. Pipes may be laid / fixed in sunken floors, under slung from ceiling. The pipes laid in sunken floor shall be encased with 75 mm thick cement concrete (1:2:4) all around. The installation shall be complete in all respects including cutting chases / holes in walls, slabs and making good the same as per specifications. (For Internal Toilet Only) 75mm dia

87

-

-

... More
Providing, jointing, testing and fixing UPVC Soil, Waste & Vent system conforming to IS : 13592 - Type B and UPVC fittings (moulded as well as fabricated) like bends, tees, Y-tees, crosses, boss connections, access pieces, saddle pieces, cleanouts, adaptors for connections to other materials, plugs, reducers, cowls, offSet and other specials. Jointing shall be done with pushfit EPDM ring jointing technique in general. Solvent cement joints may be provided for fittings and specials which are not manufactured with pushfit rubber joints. Pipes may be laid / fixed in sunken floors, under slung from ceiling. The pipes laid in sunken floor shall be encased with 75 mm thick cement concrete (1:2:4) all around. The installation shall be complete in all respects including cutting chases / holes in walls, slabs and making good the same as per specifications. (For Internal Toilet Only) 110mm dia

95

-

-

... More
Providing, jointing, testing and fixing UPVC Soil, Waste & Vent system conforming to IS : 13592 - Type B and UPVC fittings (moulded as well as fabricated) like bends, tees, Y-tees, crosses, boss connections, access pieces, saddle pieces, cleanouts, adaptors for connections to other materials, plugs, reducers, cowls, offSet , vent cowl and other specials. Jointing shall be done with pushfit EPDM ring jointing technique in general. Solvent cement joints may be provided for fittings and specials which are not manufactured with pushfit rubber joints. Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. The installation shall be complete in all respects including cutting chases / holes in walls, slabs and making good the same as per specifications. (For Soil/waste shaft Only) 110 mm dia

300

-

-

... More
Providing, jointing, testing and fixing uPVC soil, waste, rain pipework comprising UPVC pipe conforming to IS :4985-1983 and of required class as specified below and fittings (moulded as well as fabricated) like bends, tees, Y-tees, crosses, boss connections, access pieces, saddle pieces, cleanouts, adaptors for connections to other materials, plugs, reducers, cowls, offSet , vent cowl and other specials. Jointing shall be done with solvent jointing technique in general. Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. The installation shall be complete in all respects including cutting chases / holes in walls, slabs and making good the same as per specifications. (For under ceiling run of soil/waste/rain pipes Only) 110mm dia

20

-

-

... More
Providing and fixing Heavy class SS grating with Cockroach proof SS strainer of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and FT. Size 100 mm x 100 mm

42

-

-

... More
Providing, fixing, jointing, testing and commissioning uPVC of pressure rating 0.60 Mpa Rain water downtake pipe conforming to EN :14366 cut to required lengths including all necessary fittings and specials. Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. as required for proper seismic loading as per the calculations. Making proper connection with cement solvent joint as per BIS / manufacturer. Cutting chases/holes in floors/walls/slab. (Resi Towers - Service floor to Ground & Office towers - All Down take RWP pipe only). The seismic calculations shall be submitted by the contractor. 160 mm dia

50

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes

52

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes

40

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal outer dia Pipes

25

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes

10

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm nominal outer dia Pipes

5

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm nominal outer dia Pipes

10

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm nominal outer dia Pipes

60

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm nominal outer dia Pipes

40

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore

9

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore

5

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore

5

-

-

... More
Providing & fixing CI butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, flanges, nuts, bolts, washers & painting complete as required. 50 mm dia

1

-

-

... More
Providing and fixing Auto Air Purge Valve with screwed ends of approved quality. 15mm dia

6

-

-

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:. 180x150 mm size P type With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

5

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 (1 cement: 4 coarse sand )with R.C.C top slab with 1:2:4 mix (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design: Inside size 90x80 cm and 45 cm deep including C.I cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg): With common burnt clay F.P.S (NON modular) bricks of class designation 7.5

5

-

-

... More
Constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement: 3 coarse sand: 6 graded stone aggregate 40mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement all complete as per standard design: 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182kg., fixed in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With F.P.S. bricks class designation 75

15

-

-

... More
Supply & commissioning of horizontal/ vertical openwell submersible pump for water transfer with CI impeller and SS/CI motor body. Filter Feed pump cum overhead lift pump Capacity : 2 LPS Head : 55 Mtr (Head to be reaffirmed by vendor as per site inspection)

1

-

-

... More
Supply, installation, testing & commissioning of Multi Grade Pressure Sand Filter consisting of FRP composite vessel including top hub lateral strainers, bottom fish bone, base tripod, aeration valve including media complete in all respect as directed by the consultant. Vessel Make : Pentair Water MOC : FRP Composite Diameter : 750mm Height : 1800mm Filter Media : Anthracite, Fine & Coarse Sand 16/32 mesh, quartz sand, Gravels & Pebbles -3 grades. Max Operating Pressure : 10kg/cm2 Filter Vessel frontals including : - Upvc,50 mm,pipe and fittings. - 50 mm Multiport Valve - 2 Nos 100mm dia pressure gauge (0-10kg/cm2) Glycerine filled of Feibig/ H Guru, eqv make All coammables, gaskets,nut bolts, etc. - 1 nos sampling cock & valve - Any other item required to do the fronal work complete and as directed by the consultant

1

-

-

... More
Supply, installation, testing & commissioning of Activated Carbon Filter consisting of FRP composite vessel including top hub lateral strainers, bottom fish bone, base tripod, aeration valve including media complete in all respect as directed by the consultant. Vessel Make : Pentair Water MOC : FRP Composite Diameter : 750mm Height : 1800mm Filter Media : Anthracite, Fine & Coarse Sand 16/32 mesh, quartz sand, Gravels & Pebbles -3 grades. Max Operating Pressure : 10kg/cm2 Filter Vessel frontals including : - Upvc,50 mm,pipe and fittings. - 50 mm Multiport Valve - 2 Nos 100mm dia pressure gauge (0-10kg/cm2) Glycerine filled of Feibig/ H Guru, eqv make All coammables, gaskets,nut bolts, etc. - 1 nos sampling cock & valve - Any other item required to do the fronal work complete and as directed by the consultant

1

-

-

... More
Supply necessary equiments, consumable to set up a necessary Water testing kit (for minimum 200 sample tests) in the plant room to test raw water samples to minitor the water quality continiously. The kit should be able to test the following parameters: PH Level

1

-

-

... More
Supply necessary equiments, consumable to set up a necessary Water testing kit (for minimum 200 sample tests) in the plant room to test raw water samples to minitor the water quality continiously. The kit should be able to test the following parameters: Residual Chlorine

1

-

-

... More
Supply necessary equiments, consumable to set up a necessary Water testing kit (for minimum 200 sample tests) in the plant room to test raw water samples to minitor the water quality continiously. The kit should be able to test the following parameters: Hardness

1

-

-

... More
Supply necessary equiments, consumable to set up a necessary Water testing kit (for minimum 200 sample tests) in the plant room to test raw water samples to minitor the water quality continiously. The kit should be able to test the following parameters: Iron Content

1

-

-

... More
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m: All kinds of soil

725

-

-

... More
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan, getting out and disposal of excavated earth within campus including levelling and neatly dressing of disposed soil complete as directed by Engineer-in-Charge: All kinds of soil

75

-

-

... More
Ploughing the existing ground to a depth of 15 cm to 25 cm and watering the same. All kinds of soil

725

-

-

... More
Supplying and stacking of good earth at site including royalty and carriage upto 10 km complete (earth measured in stacks will be reduced by 20% for payment).

100

-

-

... More
Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 10 k.m.lead complete (Cattle manure measured in stacks will reduced by 8% for Payment).

90

-

-

... More
Supplying & Stacking of Selection No.1/doob grass at site fresh & free from weeds having proper roots in green including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge.

180

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge

190

-

-

... More
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).

260

-

-

... More
Fine dressing of the ground.

550

-

-

... More
Grassing with selection No. 1/ Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately). In rows 5 cm apart in both directions

550

-

-

... More
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately)

75

-

-

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Holes 60 cm dia, and 60 cm deep

700

-

-

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Holes 45 cm dia, and 45 cm deep

2900

-

-

... More
Edging with bricks laid dry length wise, including required excavation, refilling, consolidating with hand packing and spreading surplus earth neatly within a lead of 50 m : Common burnt clay F.P.S (non modular) bricks of Class designation 7.5

100

-

-

... More
Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded).

75

-

-

... More
Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge.

50

-

-

... More
Providing and displaying of Aglaonema Silver Queen having 30 cm to 45 cm. ht. with 12 to 15 leaves, multi suckers, fresh and healthy leaves, well developed in 25 cm dia Earthen pot/Plastic pot & as per direction of the officer-in-charge.

50

-

-

... More
Providing and displaying of Aglaonema nitida having ht. 30 cm to 45 cm with 8 to 10 leaves, well developed, fresh and healthy with attractive leaves in 25 cm size of Earthen pot/Plastic pot.& as per direction of the officer-in-charge.

50

-

-

... More
Providing and displaying of Araucaria cookie having ht. 1.20 m to 1.35 m, straight, well developed, fresh and healthy with lush green leaves from bottom to top in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.

50

-

-

... More
Providing and displaying of Areca Palm having ht. 1.20 m to 1.50 m with 5 to 6 suckers, well developed, fresh and healthy with lush green foliage in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge

50

-

-

... More
Providing and displaying of Brassia Variegated having ht. 30 cm to 45 cm, well developed with fresh and healthy foliage in 25 cm size of Earthen pot /Plastic pot. & as per direction of the officer-in-charge.

50

-

-

... More
Providing and displaying of Croton golden (Broad Leaves) having ht. 60 cm to 75 cm with 3 to 4 branches, well developed, fresh and healthy leaves in 25 cm size of Earthen pot/Plastic pot. & as per direction of the officer-in-charge.

50

-

-

... More
Providing and displaying of Croton Petra Bangalore variety having ht. 60 cm to 75 cm with 4 to 6 branches, well developed, fresh and healthy colorful leaves in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.

50

-

-

... More
Providing and Displaying of Dracaena pendanus, well developed, having 6 to 8 suckers with healthy foliage in 25 cm size Earthen pot/Plastic pot & as per direction of the officer-in-charge.

50

-

-

... More
Providing and displaying of Dracaena rosea having ht. 30 cm & above with 8 to10 leaves, well developed, fresh and healthy in 20 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.

50

-

-

... More
Providing and displaying of Philodendron Oxicodium Golden Colour Mounted on moss stick 1.20 m ht., having 3 to 4 s placed at equal distance, well developed with full of fresh & healthy leaves in 25 cm size of Earthen pot/ Plastic pot & as per direction of the officer-in-charge.

50

-

-

... More
Providing and Displaying Chrysanthemum double variety, well developed, having 45 to 60 cm ht., with 6 and above flowers with half blooming condition, fresh and healthy with bamboo stacking in 25 cm Earthen Pot and as per direction of the officer-in-charge.

100

-

-

... More
Providing and Displaying Asiatic lilly hybrid variety (3 in one) in each pot having in full bloom 3 to 5 flowers 30 to 45 cm ht. well developed in 25 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.

100

-

-

... More
Providing and Displaying Daisy well developed with fresh & healthy foliage in full bloom in 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.

100

-

-

... More
Providing and Displaying Dahlia single in different colour with fresh & healthy foliage well developed with 6 to 8 half blooming buds in 20 cm Earthen Pot/ Plastic Pot and as per direction of the officer-in-charge.

100

-

-

... More
Providing and Displaying Dianthus in different colour well developed with fresh & healthy foliage 30 cm ht., in full bloom with stacking in 25 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.

100

-

-

... More
Providing and Displaying Geranium double variety having 30 cm ht., in different colour well developed with fresh & healthy foliage (3 in one) well bloomed in 25 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.

100

-

-

... More
Providing and Displaying Gerbera Hybrid, well developed, with fresh and healthy foliage, fully blooms in 25 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.

100

-

-

... More
Providing and Displaying Marigold jaffri French orange/yellow/Russet colour well developed with fresh & healthy foliage with 60 to 75 flowers in bloom specimen plant 60 to 75 cm ht in 30 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.

50

-

-

... More
Providing and Displaying Nasturtium in different colour well developed with fresh & healthy foliage with full bloom in 20 cm Earthen Pot/Plastic Pot as per direction of the officer-in-charge.

100

-

-

... More
Providing and Displaying Pansy Hybrid Sakata in different colour specimen 6-8 in a pot with fresh & healthy foliage in full bloom well developed in 35 cm Earthen Tray/ Nand as per direction of the officer-in-charge.

50

-

-

... More
Providing and Displaying Petunia hybrid different colour single well developed in full bloom in 20 cm Earthen/Plastic Pot and as per direction of the officer-in-charge.

100

-

-

... More
Providing and Displaying Verbena in different colour having 30 to 45 cm ht., well developed with fresh & healthy foliage in bloom condition in 25 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.

100

-

-

... More
Providing and Displaying Cosmos well developed fresh & healthy 20 to 25 cm ht. attractive colors multi branching at blooming stage in 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.

100

-

-

... More
Providing and Displaying Gaillardia double hybrid variety well developed 30 to 45 cm ht 20 to 30 fresh & healthy flower with green painted bamboo stick in 25 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.

100

-

-

... More
Providing and Displaying Sunflower single well developed 8 to 10 half bloom buds multi branched in fresh & healthy full stacked with green painted bamboo stick stacking in 25 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.

50

-

-

... More
Providing and Displaying Zinnia hybrid double in different colour well developed fresh & healthy 30 to 45 cm ht. (3 to 4 in each pot) full bloom in 25 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.

50

-

-

... More
Providing and Displaying Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge.

25

-

-

... More
Providing and Displaying Creeper Rose variety 3 to 4 healthy branch 60 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge.

25

-

-

... More
Providing and Displaying Acalypha green well developed, fresh & healthy with good foliage, multi branch 30 to 45 cm ht. in 20 cm size Earthen Pot/ Plastic Pot bushy as per direction of the officer-in-charge.

100

-

-

... More
Providing and Displaying Acalypha red well developed with fresh & healthy 30 to 45 cm ht. in 20 cm size Earthen Pot/ Plastic Pot as per direction of the officer-in-charge.

100

-

-

... More
Providing and Displaying Acalypha twisted well developed with fresh & healthy 30 cm ht. in 20 cm size Earthen Pot/ Plastic Pot as per direction of the officer-in-charge.

100

-

-

... More
Providing and Displaying Bamboo Buddha vally variety with umbrella shape having 120 to 135 ht. with fresh & healthy foliage well developed in 40 cm Cement pot multy branch, bushy as per direction of the officer-in-charge.

10

-

-

... More
Providing and Displaying Bird of paradise well developed with fresh & healthy 90 to 120 cm ht in 30 cm Earthen Pot/ Plastic Pot as per directionof the officer-in-charge.

25

-

-

... More
Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge.

10

-

-

... More
Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge.

10

-

-

... More
Providing and Displaying Ficus Retusa topiary well developed with fresh & healthy 5 to 6 big ball specific size and shape 180 to 210cm ht in 40 cm Cement Pot as per direction of the officer-in-charge.

5

-

-

... More
Providing and Displaying Fishtail palm well developed with fresh & healthy foliage leaves of ht 210 to 240cm Specimen in 35 cm Cement Pot as per direction of the officer-in-charge.

10

-

-

... More
Providing and Displaying Foxtail palm well developed with fresh & healthy foliage of ht. 210 to 240 cm in big 40 cm Cement Pot as per direction of the officer-in-charge.

5

-

-

... More
Providing and Displaying Topiary of Ficus Bush King well developed with fresh & healthy foliage from Top to Bottom with single piller 60 to 75 cm spread, 210 to 225 cm ht., in 35 cm Cement Tray/Cement Pot as per direction of the officer-in-charge.

25

-

-

... More
Providing and Displaying Topiary of Casuarina fresh & healthy having 5 to 6 specific shape and size ball well developed 195 to 210 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge.

5

-

-

... More
Providing and Displaying Travelers palm well developed with fresh & healthy leaves foliage 210 to 240 cm ht specimen in 40 cm Cement Pot as per direction of the officer-in-charge.

5

-

-

... More
Providing and stacking of Asparagus marrie, well developed 15 to 20 leaves, full of branches and foliage in 25 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.

100

-

-

... More
Providing and stacking of Aspidistra, having 10 to 15 leaves well developed with fresh & healthy in 25 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.

100

-

-

... More
Providing and stacking of Chlorophytum (Green), full of leafy suckers in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.

100

-

-

... More
Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge..

200

-

-

... More
Providing and stacking of Ophiopogon jaburan (variegated ), full of variegated leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.

200

-

-

... More
Providing and stacking of Syngonium variegated,of height 20-30 cm. with 2-3 suckers healthy foliage in Earthen Pot/Plastic Pot of size 15 cm. as per direction of the officer-in-charge.

200

-

-

... More
Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
Providing and stacking of Bauhinia purpurea (Kachnar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
Providing and stacking of Bauhinia blakeana (Kachnar) of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
Providing and stacking of Bottle palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big HDPE bags as per direction of the officer-in-charge

5

-

-

... More
Providing and stacking of Butea frondosa (Flame of Forest) of height 60-75 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.

5

-

-

... More
Providing and stacking of Cassia siamea of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
Providing and stacking of Fishtail palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big size HDPE bags as per direction of the officer-in-charge.

5

-

-

... More
Providing and stacking of Heterophragma adenophyllum (Marore fali) of height 150-165 cm. in Big poly bag of size 25 cm as per direction of the officer-in-charge.

5

-

-

... More
Providing and stacking of Michelia champa (Golden Champa) of height 90-105 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.

5

-

-

... More
Providing and stacking of Mimusops elengi (Maulsri) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.

5

-

-

... More
Providing and stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge.

3

-

-

... More
Providing and stacking of Phyllanthus emblica (Amla) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge.

5

-

-

... More
Providing and stacking of Plumeria acutifolia of height 150-165 cm. with 3-4 branches in big size HDPE bag as per direction of the officer-in-charge.

5

-

-

... More
Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.

5

-

-

... More
Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge.

30

-

-

... More
Providing and stacking of Schleichera trijuga (Kusum) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
Providing and stacking of Spathodea campanulata of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.

5

-

-

... More
Providing and stacking of Washingtonia filifea palm stem ht. 120-135 cm with 8-10 healthy leaves lush green leaves well developed in big size HDPE Bags as per direction of the officer-in-charge.

3

-

-

... More
Providing and stacking of Bauhinia acuminata height 60-75 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge.

100

-

-

... More
Providing and stacking of Bauhinia tomentosa (yellow) of height 60-75 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge.

100

-

-

... More
Providing and stacking of Caesalpinia pulcherrima species of height 45-60 cm. in earthen pot of size 20 cm as per direction of the officer-in-charge.

25

-

-

... More
Providing and stacking of Cassia biflora of height 90-105 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge.

5

-

-

... More
Providing and stacking of Cestrum nocturnum (Raat ki Rani) of height 60-75 cm. with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge.

5

-

-

... More
Providing and stacking of Dombeya mastersii of height 60-75 cm. with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge.

5

-

-

... More
Providing and stacking of Euphorbia pulcherrima (dark red) well branched (poinsettia Red Hegg) of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.

25

-

-

... More
Providing and stacking of Ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
Providing and stacking of Ficus blackii (F.vivion) (bushy) of height 150-165cm. with 8-10 branches and healthy foliage in earthen pots of size 30 cm as per direction of the officer-in-charge.

10

-

-

... More
Providing and stacking of Gardenia jasminoides of height 45-60 cm. with 3-4 branches in earthen pots of size 20 cm as per direction of the officer-in-charge.

5

-

-

... More
Providing and stacking of Hamelia patens of height 60-75 cm. with 6-8 branches in poly bags of size 25 cm as per direction of the officer-in-charge.

20

-

-

... More
Providing and stacking of Hibiscus rosasinensis of height 60-75 cm. with 5-6 branches in p.bag of size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
Providing and stacking of Murraya exotica of height 45-60 cm. in poly bags of size 15 cm as per direction of the officer-in-charge.

20

-

-

... More
Providing and stacking of Nerium oleander variegated of height 45-60 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge.

20

-

-

... More
Providing and stacking of Tabernaemontana coronaria (Chandni single) of height 90-105 cm.,bushy in big size HDPE bag as per direction of the officer-in-charge.

10

-

-

... More
Providing and stacking of Thuja compacta of height 75-90 cm., conical shaped, well formed with healthy foliage in earthen pots of size 30 cm as per direction of the officer-in-charge.

5

-

-

... More
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) Trees Plant

136

-

-

... More
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) Shrubs Plant

1145

-

-

... More
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) Hedge Plant /Ground cover

2350

-

-

... More
Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick river sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge.

420

-

-

... More
Providing & fixing of White River (Stone) Pables size of 2" to 2.50" dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge.

10

-

-

... More
Supplying and installation of pole mounted litter bin, each set a pair of 100Ltr capacity bin all complete as directed by the Engineer-in-Charge (Nilkamal or approved equivalent)

6

-

-

... More
Supplying and installation of sheet metal outdoor benches with backrest, SS 304 grade, hairline Satin or Mirror finish and laser cut perforated seating with fins/separators with 2 legs made of 2mm thick SS sheet fixed with the help of push-fit components and of size 1700mm (L) x 450mm (W) x 425mm (H) all complete as per approved brand and model/design including placing the bench in position by grouting in cement concrete blocks complete as directed by the Engineer-in-Charge (cement concrete block shall be paid separately) Ozone Model No. OZ-UF-BN-33 or approved equivalent

5

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C

154

-

-

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C

400

-

-

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.

5

-

-

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

790

-

-

... More
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

50

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

50

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

1200

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire

50

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 10 sq. mm + 1 X 6 sq. mm earth wire

150

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 16 sq. mm + 1 X 6 sq. mm earth wire

200

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire

20

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire

50

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire

150

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire

200

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch

4

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2 way 5/6 A switch

6

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch

2

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet

8

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet

6

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Bell push

10

-

-

... More
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

28

-

-

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

20

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/ 6 A modular switch, connections etc. as required.

2

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

135

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

52

-

-

... More
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

20

-

-

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

2

-

-

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

28

-

-

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep

12

-

-

... More
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.

5

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75 mmX75 mm)

5

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100 mmX75 mm)

6

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4 Module (125 mmX75 mm)

5

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200 mmX75 mm)

3

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125 mmX125 mm)

2

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 12 Module (200 mmX150 mm)

1

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) 6 way, Double door

9

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) 8 way, Double door

1

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) 12 way, Double door

1

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 4 way (4 + 12), Double door

1

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 6 way (4 + 18), Double door

9

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 8 way (4 + 24), Double door

1

-

-

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4 + 36), Double door

1

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole

189

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral

5

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole

5

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole

5

-

-

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

30

-

-

... More
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps

5

-

-

... More
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps

6

-

-

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps

9

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps

1

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps

33

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps

1

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A

10

-

-

... More
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.

10

-

-

... More
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

-

-

... More
Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

-

-

... More
Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

6

-

-

... More
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

2

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness

10

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness

70

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 450 mm width X 50 mm depth X 2.0 mm thickness

40

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness

8

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 450 mm width X 50 mm depth X 2.0 mm thickness

4

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness

8

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 450 mm width X 50 mm depth X 2.0 mm thickness

4

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays Tee's with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays Tee's with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness

7

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays Tee's with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 450 mm width X 50 mm depth X 2.0 mm thickness

3

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays cross members with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays cross members with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness

6

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays cross members with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 450 mm width X 50 mm depth X 2.0 mm thickness

2

-

-

... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

2

-

-

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

28

-

-

... More
Supply, Installation, Testing & Commissioning of 15 w WALL FOCUS LIGHT

33

-

-

... More
Supply, Installation, Testing & Commissioning of recess/Surface mounted round LED luminaire 12 watt, made of shigh pressure die cast aluminium alloy body having white powder coating with high efficiency PS diffuser for homogeneous light distribution. Fixture should have minimum efficacy at System level (Not Chip Level) ≥100 lumens/watt and a minimum system lumen output of 1200 lumens. Luminaire should have 70% of luminous flux after 50,000 operating hours (L70), CCT 5700K, CRI 80, PF 0.95, THD10%, IP20, UGR19, Operating working temp range - 0°C Ta 35°C and an operating Voltage Range of 140 - 270V. Internal Surge Protection ≥ 2.5KV & external SPD ≥ 5 Kv. The fixture design should comply with EMC / EMI compliance, comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, Cut out of Ø165 mm. Fixture height should not less than 40mm, LED Make- Cree/Nichia/Lumileds/Osram. Make: Philips/LT/Havells/Shaffer/Legero

179

-

-

... More
SITC of recess mounted LED luminaire (2X2) with 5700K,made CRCA/ PDC aluminium housing having powder coating with high efficiency PC/PMMAdiffuser for homogeneous light distribution. Fixture should have minimum efficacy at System level (Not Chip Level) ≥120 lumens/watt and a minimum system lumen output of 3600 lumens. Luminaire should have 70% of luminous flux after 50,000 operating hours (L70), CCT of 5700/6500K, CRI 80, PF 0.95, THD10%, IP20, UGR19, Operating working temp range - 0°C Ta 35°C and an operating Voltage Range of 140 - 270V. Internal Surge Protection ≥ 2.5KV & external SPD ≥ 5 Kv. The fixture design should comply with EMC / EMI compliance, comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, Cut out of 575mm x 575mm, LED Make- Cree/Nichia/Lumileds/Osram Make: Philips/LT/Havells/Shaffer/Legero

155

-

-

... More
SITC of pre-wired 1200mm, 18/20Watt LED Light fitting complete with all accessories, housing made of Aluminium, System Efficasy -120 LPW or above and a minimum system lumen output of 2160 lumenswith CRI 80, 5700K. suitable for 220 V, 50 Hz, The luminare rated life (L70) 50000 Hours with High efficiency driver withInternal Surge Protection ≥ 2.5KV, over voltage protection, short circuit protection and operating at 0.95 PF. 10% THD (Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc as required. Submission of LED Photo biological safety report confirming to 62471, LED Make- Cree/Nichia/Lumileds/Osram. Make: Philips/LT/Havells/Shaffer/Legero

71

-

-

... More
Supply, Installation, Testing & Commissioning of surface mounted Bulkhead light with 5700K, made of PDC aluminium housing having powder coating with high efficiency PC/PMMAdiffuser for homogeneous light distribution. Fixture should have minimum efficacy at System level (Not Chip Level) ≥100 lumens/watt and a minimum system lumen output of 1200 lumens. Luminaire should have 70% of luminous flux after 50,000 operating hours (L70), CCT of 5700/6500K (SDCM4), CRI 80, PF 0.95, THD10%, IP-66, Operating working temp range - 0°C Ta 35°C and an operating Voltage Range of 140 - 270V. Internal Surge Protection ≥ 2.5KV & external SPD ≥ 5 Kv. The fixture design should comply with EMC / EMI compliance, comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI/EMC. Cut out of 575mm x 575mm, LED Make- Cree/Nichia/Lumileds/Osram. Make: Philips/LT/Havells/Shaffer/Legero

18

-

-

... More
Supply, Installation, Testing & Commissioning of 1x11W 'S' type LED Mirror Light.

21

-

-

... More
Supply of LED exit signage of Box size in mm 325x425x365.

10

-

-

... More
Fresh air fan 250 mm

12

-

-

... More
Supply of Ceiling Fan of 1200mm sweep complete erected in position with all accessories.

28

-

-

... More
Supplying of Exhaust Fan Heavy duty 230V A.C 50 cycles 375 mm 1400 RPM complete erected in position with all accessories.(Make- Havels)

1

-

-

... More
11 kV 2 POLE STRUCTURE Supply, installation, testing & commissioning of two 11Mtr. pole structure, 11KV with cross arms, suitable clamps, insulators, disc insulators, 11KV lightning arrestors, complete stay with insulator & wire, foundations, gang operated air break switch with extended handle, 11KV drop out fuses. This shall have termination arrangement for outgoing through HT XLPE cable of suitable size and necessary 6 inches dia GI pipe shall be provided for cable support complete in every way. 11 kV HT 'H' pole as per specification & as described above

1

-

-

... More
11 KV HT Metering Panel (SEB's) The instrument and relay panel fitted with: 1- digital voltmeter scaled 0-11000volt with 3 way and OFF selector switch. 1- digital Ammeter scaled 0-75 amps with 3 way and OFF selector switch. 1- Triple pole I.D.M.T. overcurrent & earth fault relay with two outer elements connected for overcurrent protection and the middle element for earth fault protection overcurrent, setting 50% - 200%, Earth fault setting 20% - 80% (51 and 51N). 1 No. SEB approved digital Trivector meter with MDI in KVA of accuracy class - 0.5. Note: The contractor shall get the Trivector meter , CTs' & PT tested by SEB and the charges for liasioning for the same will be paid extra. One Set of Phase Indicating Lamps. 1- set of Red/Green indicating lamps for close and open position 1- Amber indicating lamp for auto trip 1- clear indicating lamp for trip circuit healthy 1- set of white indicating lamps one per phase 1 - blue indicating lamp for spring charged 2 Nos. indoor cable end box suitable for 3C x 300 sq.mm. 11 KV(E), aluminium conductor XLPE Ar. cable (Incoming & Outgoing cable). Supply Rate for Metering Panel as described above Note: The contractor shall ensure that the above panel meets the requirement as insisted by Gujarat State Electricity Board authorities for satisfactory operation and as per the Drawings. If State electriity Board will Provide the HT meter with CT-PT Metering unit then this item NS-1.2 will not payed to the contractor.

1

-

-

... More
Unitized SubStation Supplying, installation, testing & commissioning of outdoor package Substation floor mounted with, a) 11 KV 630A VCB for protection at HT side b) 400KVA, Dry type, 11/0.433 KV, 3 Phase, 50 Hz, Double Wound with copper Winding with OLTC (As per ECBC 2018 & IS : 11171 -1985 & IS : 2026/77), Impedance 5%, Tapping Range Tappings -15.0% to +10.0% in steps of 2.5% shall be provided at line end of HV winding. Changing of taps shall be carried out by means ON Load tap changing, Insulation class : class F ,Temperature rise by Resistance : 90 deg.c , Ambient Temperature 50 deg.c, Dyn 11 vector group. Outgoings in LT side :- c) 1 No. 630A,4P ACB, 50KA, Microprocessor based.

1

-

-

... More
Supply, installation, testing & commissioning of 125 KVA continuous rating,silent type (Prime Rating) radiator cooled diesel generating set alongwith complete fuel oil piping, antivibration mounts, base frame, required hardware, Batteries, Engine control panel with accessories, residential silencer, flexible connection, bellow / expansion joints etc.complete with all associated equipment / work as per specifications or requirements as per site.

2

-

-

... More
DG set shall be supplied with built in acoustic enclosure as per pollution control board norms and as per specification complete in all respect. The DG Set shall be complete with PCC (Power Command Control) or equivalent DG Controller module suitable for AMF (auto-mains failure), Auto Load Sharing & Interface with PLC mounted in the LT panel for ACB/MCCB switching and Auto load sensing and Auto load Management, including communication card and networking gateway and software as required. Note: Item rate shall be include 1st time filling of Lube oil & diesel and also include the cable termination box suitable for termination of 4 Runs 3.5 C X 300 Sqmm. XLPE AL cables at alternator. Battery charger for 1X125 KVA DG sets Supply, installation, testing & commissioning of Battery Charger as described in Specifications and described below: Rating AC Input: 230 V + 10% AC 50 Hz single phase. DC Output: To float / boost charge the batteries (with required AH as per D.G. rating) and also supply a continuous load or as per offered DG set requirement. Current Rating: 30 A Float Mode: 27.0 V nominal (Adjustable) between 24-28.0 V. Boost Mode: 29.0 V nominal (Adjustable) between 24-32.0 V Voltage Regulation:+ 2% for AC input variation of 230 V + 10%. Frequency Variation of 50 Hz + 5% and DC load variation 0-100% Ripple:Less than 5% Battery Charger Unit as described above Day Oil Tank

-

-

-

... More
Supply, installation, testing & commissioning of 990 litres capacity day oil storage tank fabricated from 6 mm thick MS plates. Tank shall include 450 mm ID manhole cover, level indicator with duly calibrated scale and flanged connection for inlet, outlet, overflow drain and probe provision for level controller & breather.

2

-

-

... More
Oil Piping Supply, installation, testing & commissioning of the following MS class ‘C’ pipes cut to required lengths and installed with all welded joints. Providing the necessary fittings like elbows, tees and reducers, sockets, hot dip galvanized supports and accessories including ceiling Hanger, Hardware complete as per site requirement. 25 mm dia MS pipes(For 125 KVA DG Set)

25

-

-

... More
Providing 25 mm dia. ball valves (For 125 KVA DG Set)

2

-

-

... More
Exhaust Piping & Thermal Insulation Supply, installation, testing & commissioning of MS class-C exhaust pipe as per IS 1239 and all fixing accessories and hardwares. The exhaust pipes shall be insulated with 75 mm thick mineral wool (density 150 kg/m3) insulation wrapped in chicken mesh and clad with 26 gauge aluminium sheet including all hot dip galvanized support structural as required. 180 mm dia MS class-C pipe & 75mm thick mineral wool insulation as per description given above.

30

-

-

... More
Note: Contractor should furnish calculation for exhaust piping size for approval by the Consultant. The system should meet the performance of the engine without exceeding the back pressure limit prescribed by engine supplier.

-

-

-

... More
Support Structure Supply, installation, testing & commissioning of miscellaneous structural support (MS angle iron / MS Plates / MS Channel etc.) for horizontal/vertical exhaust piping at suitable interval as per approved Shop drawing including fabrication, hardwares / flanges and painting (2 coats of primer and 2 coats of enamel paint) complete in all respect.

220

-

-

... More
Supply, installation, testing & commissioning of 300 mm dia Flexible Bellows

2

-

-

... More
Supply, installation, testing & commissioning of 180 mm dia Flexible Bellows

2

-

-

... More
Supply, installation, testing & commissioning of Thermal Cladding of Silencers

2

-

-

... More
Supply, installation, testing & commissioning of following 1100 volt grade XLPE PVC insulated sheathed copper conductor armoured cable including supplying of bimettalic crimping lugs, double compression glands with earthing. as per specification. 4 C x 2.5 sq.mm control cable

50

-

-

... More
Supply, installation, testing & commissioning of following 1100 volt grade XLPE PVC insulated sheathed copper conductor armoured cable including supplying of bimettalic crimping lugs, double compression glands with earthing. as per specification. 12 C x 2.5 sq.mm control cable

60

-

-

... More
Control Cables Termination: Supply, installation, testing & commissioning of all materials and making terminations of control cable terminations for control cables as per item 7.6 above complete with single brass compression glands, copper lugs etc. as required: 4 C x 2.5 sq.mm control cable

3

-

-

... More
Control Cables Termination: Supply, installation, testing & commissioning of all materials and making terminations of control cable terminations for control cables as per item 7.6 above complete with single brass compression glands, copper lugs etc. as required: 12 C x 2.5 sq.mm control cable

3

-

-

... More
LT PANELS & DISTRIBUTION BOARDS The contractor shall consider the following details in their item rates, wherever required: • Supporting rigid steel framework. • Cubicle type, 14 gauge CRCA sheet steel enclouser. • Complete with interconnections and distribution bus bars. • Proper bonding to earth. • Painting/lettering on Breakers and distribution boards, the location they serve, providing on each panel its circuit diagram. • Providing cable clamps / supports within distribution boards cable alley. • TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequate size of neutral link. • All MCB’s shall be of minimum 10 KA breaking capacity. • All motor feeders MCCBs shall be of motor duty. • Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5. • Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993. • IP 42 for indoor panels. • IP 54 for kitchen and laundry panels. • IP 55 for outdoor panels • All MCCB’s shall be provided with operating mechanism for door interlock. • Current density of aluminium shall be 1 sq mm for 1.0 amps for rated current of bus bars and current density of copper shall be 1 sq.mm for 1.25 amps for rated current of bus bars. • Tinned copper earth bus shall be provided through out the length of each board.

-

-

-

... More
• All measuring instruments (Meters) shall be of digital electronic with LED of approved make and compatible with BAS. • All hinged door shall be earthed through 4.0 sq mm tinned braided copper wire. • All panels shall have provision of the following: • Pad locking of Switch board doors. • Pad locking of MCCB’s handles in “OFF” Position. • Additional set of C.T.s, potential free contacts, connectors, contactors with wiring etc are to be provided for BAS including space required for various transducers in Main Switch Board sections. Only transducers shall be supplied by BAS contractor. • All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic. • All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation. • All PTs / control transformer shall be provided with centre tap earth secondary. • All DOL & Star-Delta Starters shall be provided with SPPR (single phase preventor relay) and 2 nos. of Aux.Contacts for Remote operation/monitor. • The Panel fabricator shall provide Al./ Copper Bus-bars link from Breakers wherever more than two nos. of cables are terminated in the breakers.

-

-

-

... More
• Readymade 16 SWG Sheet steel Enclosure with cutout For MCBs • The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with thermal magnetic releases upto 250 amps and miroprocessor based above 250 amps capacity, unless specified otherwise. • ACB shall comply with standards IS/IEC 60947-1 & 2 • ACB shall have a rated operational voltage of 415V AC, rated insulation voltage of 1000 volts AC, rated impulse voltage of 12kV. • ACB shall have a Ready to close mechanism preferably having a ready to close mechanical indication on front of ACB. All EDO ACBs ready to close indication contact • ACBs upto 3200A shall be provided with top horizontal and bottom vertical terminal adapters on both sides for proper cable connections/bus duct connections. • MCCB shall have a rated operational voltage (Ue) of 415V, insulation voltage (Ui) of 690 V (AC 50/60 Hz) & impulse voltage (Uimp) of not less than 8kV. • MCCBs shall be current limiting type having a double break design • Protection Releases Microprocessor based (PRMB) & Thermal magnetic (PRTM) shall be as described below .

-

-

-

... More
A) Protection Release Microprocessor Based (PRMB-1) For ACB Over-current/long time protection range 40% - 100 % with Time setting short circuit /short time protection range 100% - 1000 % with Time setting Instantaneous short circuit Protection range 150% - 1200 % with Time setting Earth Fault Protection range 20% - 100 % with Time setting ZSI(Zone Selectivity Interlocking) Measurements Voltage Current Energy B) Protection Release Microprocessor Based (PRMB-3) For MCCB Overload protection short circuit protection C) Protection Release Thermal-Magnetic Based (PRTM) For MCCB Over-current Short circuit

-

-

-

... More
A) Design, fabrication, assembly, wiring and supply of front operated dead front cubicle type compartmentalised as per Form 3B, rear access free standing, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for a symmetrical fault level of 50 kA at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below. (Note:The contractor may select the next higher fault rating of MCCB if it is not readily available ,without any extra cost ,as the figure indicated within the bracket are required maximum fault level of the panel).

-

-

-

... More
MAIN LT Panel IP:42 A) INCOMER FROM TRANSFORMER • BUSBAR-1 • From 500 KVA Transformer-1(PSS) • 1 No. 800A 4 pole microprocessor based Motarized MCCB (36kA) with integral protection as per PRMB-1 mentioned in Preamble • 1 set of 800/5A, 15 VA, class-1 CTs for APFC relay • 1 set of R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. • 1 No. (0-800V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB • 1 No. (0-630A) Ammeter with ASS with 3 nos. 800/5A CT's • 1Set- of ON/OFF/Trip/ Spring Charged & Trip circuit healthy indicating lamps. • 240 V AC Motor wound spring closing mechanism • 1 - 24 volts DC shunt trip coil • Terminals to receive XLPE insulated Aluminium cables • Class – B transient voltage surge suppression devices suitable for 3 phases as per specification. • Multifunction meter with display of V,I,PF,Energy,Power, Harmonics up to 15th order & %THD with RS485 port

1

-

-

... More
B) INCOMER FROM DG Set From D.G-1( 320 Kva) • 1 Nos. 250A 4 pole microprocessor based Motarized MCCB (36kA) with integral protection as per PRMB-1 mentioned in Premable • 1 set of R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. • 1 No. (0-250V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB • 1 No. (0-250A) Ammeter with ASS with 3 nos. 250/5A CT's • 1 Set- of ON/OFF/Trip/ Spring Charged & Trip circuit healthy indicating lamps. • 240 V AC Motor wound spring closing mechanism • Terminals to receive XLPE insulated Aluminium cables • Class – B transient voltage surge suppression devices suitable for 3 phases as per specification. Multifunction meter with display of V,I,PF,Energy,Power, Harmonics up to 15th order & %THD with RS485 port

-

-

-

... More
C) BUS BARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 500 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 36 kA at 415 volts. The neutral busbar is to be of 50% capacity. D) OUTGOINGS-Bus Section-1 • 3 Nos. 500A TP+NL MCCB (25 KA) • 2 Nos. 63A TP+NL MCCB (25 KA) • 4 Nos. 63A TPN MCB (10 KA) BUSBAR-2 E) INCOMER FROM DG Set From D.G-1 (125 Kva) • 1 Nos. 630A 4 pole microprocessor based EDO, ACB(50kA) with integral protection as per PRMB-1 mentioned in Premable • 1 set of R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs. • 1 No. (0-630V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB • 1 No. (0-630A) Ammeter with ASS with 3 nos. 630/5A CT's • 1 Set- of ON/OFF/Trip/ Spring Charged & Trip circuit healthy indicating lamps. • 240 V AC Motor wound spring closing mechanism • 6 nos NO/NC contacts for remote opening & closing • Terminals to receive XLPE insulated Aluminium cables • Class – B transient voltage surge suppression devices suitable for 3 phases as per specification. • Multifunction meter with display of V,I,PF,Energy,Power, Harmonics up to 15th order & %THD with RS485 port

-

-

-

... More
F) BUS BARS Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 630 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 50 kA at 415 volts. The neutral busbar is to be of 50% capacity. G) OUTGOINGS-Bus Section-2 • 2 No. 125A TP+NL MCCB (25 KA) • 4 Nos. 63A TP+NL MCCB (25 KA) • 5 Nos. 63A TPN MCB (10 KA) H) PLC PLC FEEDER- AUTO ON/OFF AND AUTO LOAD MANAGEMENT : Hardware using PLCs for Monitoring of all Electrical Software and for operations, controlling and interlocking Parameters of 1 Nos. DG & 1 Nos. Transformer with Window based software & Engineering & Software Development. Required Aux. Relays, Push Buttons & Indication lamps, 1KVA UPS for Black start & maintenance free Batteries, Power monitors, Programmable Logic controller, Annunciator and status Fascia, MIMIC with LED circuit etc as required completing the system.(As per SLD). The Switchboard with Logic control panel shall be complete with all interconnections, risers, internal wiring, labels, control/circuit fuses etc. complete as required. Note: Incomer from LT Supply, D.G. set & Bus coupler shall be electrically & mechanically interlocked. Main LT Panel as described above

-

-

-

... More
Note: • The outgoing feeders as indicated in SLD shall have suitable range of followings (except capacitor feeders) • Three phase indicating lamps protected by 2 amps SP MCBs. • All ACB's shall be suitable for minimum 50 kA ( Icu=Ics=Icw for 1 sec.) • 415/110V suitable rating control transformer and shall be provided for aux. control supply. • Wiring with space heater, thermostat and control MCB's shall be provided for all vertical sections of main LT panel. • All breakers shall be interlocked as per schematic diagram through Mini PLC with Auto load management and Amf operation control (without display) • All incoming as well as outgoing feeders shall have pad locking facility. • Suitable danger board shall be provided. • Incase of Fire, Fire pumps along with other ventilations and pressurization fans designed shall become operational. Interlocking with LT panel shall be carried out accordingly.

-

-

-

... More
Capacitor Panel-1 (135 kVAR) IP:42 INCOMER 1 No. 500A TPN MCCB (25 KA) as per PRMB-1 as mentioned in Preamble. METERING & INDICATION 1 set of phase indicating lamps 1 No. 6 step-Microprocessor APFC controller/Relay(Dual source purpose) shall continuously monitoring all three phases and LCD displays for various Electrical Parameters like voltage, input current, capacitive current, KVA demand, KW, Power Factor, self diagnostic error code indication with printout facility of the above with RS 232/RS 485 port. Controller should mounted on the front side of the panel. Capacitor bank having 3 phase MPP based mix dieelectric low loss ISI marked power capacitor and provided with contactor based switching to suppress switching of inrush current and reducing harmonics capacitor life. BUS-BAR 1 Set of 500A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS 1 Nos.of 63A TP MCCB (25 KA) each with PRTM 1 Nos. 25 KVAR capacitor Bank each with 7% harmonic & discharge resistor with thyristor module suitable capacity to carry expected current continuosly. 4 Nos.of 63A TP MCCB (25 KA) each with PRTM 4 Nos. 20 KVAR capacitor Bank each with 7% harmonic & discharge resistor with thyristor module suitable capacity to carry expected current continuosly. 2 Nos. of 32A TP MCCB (25 KA) each with PRTM

1

-

-

... More
2 Nos. 10 KVAR capacitor Bank each with 7% harmonic & discharge resistor with thyristor module suitable capacity to carry expected current continuosly. Capacitor Panel-1 (135 kVAR) as described above Note: The capacitor panel shall also stipulate the following (i) All the capacitors shall be suitable for 525 V (ii) Necessary control and firing card with proper wiring and lugs of the required rating to be provided. (iii) Heavy duty exhaust fans to be provided for cooling Thyristors. (iv) LED indication for number of capacitor banks ‘ON & Power Factor lagging or leading. (v) The APFC shall be protected from following * over-voltage & voltage unbalance * Over temperature-system should be in standby mode and automatically restart after above condition restored. * Total Harmonic Distortion

-

-

-

... More
Lift Panel IP:42 INCOMER 1 No. 63 amps 4P MCCB(25 KA) with thermal Magnetic release (PRMB-3) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION for each Incomer 1 set of R,Y,B phase indicating lamps Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA parameter) with RS-485 Port. Sets of 100/5A, CL-1, 15VA CTs for measuring. Sets of phase indicating lamp with 2A control MCBs. BUS-BAR 1 Set of 80A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS 2 Nos. 63A TP MPCB (10 KA) 1 Nos. 40A DP MCB (10 KA) 2 Nos. 40A TP MCB (10 KA) MDB- (Lift) as described above

2

-

-

... More
Fire Pump Panel IP:42 INCOMER 1 No. 63 amps 4P MCCB(25 KA) with thermal Magnetic release (PRMB-3) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION for each Incomer 1 set of R,Y,B phase indicating lamps Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA parameter) with RS-485 Port. Sets of 100/5A, CL-1, 15VA CTs for measuring. Sets of phase indicating lamp with 2A control MCBs. BUS-BAR 1 Set of 80A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS 2 Nos. 63A TP MPCB (10 KA) 1 Nos. 40A DP MCB (10 KA) 2 Nos. 40A TP MCB (10 KA) MDB- (Fire) as described above

1

-

-

... More
(UPS INPUT PANEL) INCOMER 1 Nos. 63 amps 4P MCCB(36 KA) with thermal Magnetic release (PRMB-3) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION for each Incomer 1 set of R,Y,B phase indicating lamps 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB 1 No. (0-63A) Ammeter with ASS with 3 nos. 63/5A CT's 1 No. Digital Electronic KWH meter(Dual Source). BUS-BAR 1 Set of 80A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS 3 Nos. 63A TP+NL MCCB (16 KA) UPS INPUT PANEL as described above

1

-

-

... More
UPS PANEL IP:42 INCOMER 2 Nos.63 amps 4P MCCB(16 KA) with thermal Magnetic release with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. METERING & INDICATION for each Incomer 1 set of R,Y,B phase indicating lamps Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA parameter) with RS-485 Port. Sets of 63/5A, CL-1, 15VA CTs for measuring. Sets of phase indicating lamp with 2A control MCBs. BUS-BAR 1 Set of 80A 4P Copper Bus Bar with colour coded PVC Sleeves BUS-CUPLER 1 Nos. 80 amps 4P MCCB(16 KA) with thermal Magnetic release OUTGOINGS 10 Nos. 40A DP MCB (10 KA) UPS PANEL as described above

1

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

18

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

18

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

8

-

-

... More
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.

60

-

-

... More
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe FRLSom earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.

60

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

150

-

-

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.

50

-

-

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

20

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

190

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

210

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required

100

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm

750

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 35 sq. mm and upto 95 sq. mm

60

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm

50

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 185 sq. mm and upto 400 sq. mm

28

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm

450

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 35 sq. mm and upto 95 sq. mm

100

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm

100

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 185 sq. mm and upto 400 sq. mm

200

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 35 sq. mm and upto 95 sq. mm

100

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 95 sq. mm and upto 185 sq. mm

100

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 185 sq. mm and upto 400 sq. mm

100

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)

250

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

200

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

100

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

250

-

-

... More
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

20

-

-

... More
Laying of one number XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. Above 120 sq. mm and upto 400 sq. mm

10

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 6 sq. mm (19mm)

20

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 6 sq. mm (19mm)

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 X 10 sq. mm (22mm)

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 X 70 sq. mm (35mm

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 50 sq. mm (35mm)

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 70 sq. mm (38mm)

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 95 sq. mm (45mm)

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 120 sq. mm (45mm)

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 150 sq. mm (50mm)

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 185 sq. mm (57mm)

4

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 240 sq. mm (62mm)

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 300 sq. mm (70mm)

10

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm)

20

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)

8

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 25 sq. mm (28mm)

2

-

-

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 240 sq. mm

3

-

-

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 240 sq. mm

1

-

-

... More
Supply of HT cable Supplying of following sizes of XLPE aluminium conductor, corss linked polythylene, individual core screwed, flat steel strip armoured, PVC sheathed cable of 11KV grade (earthed) comforming to IS: 7098 (Part 2),with uptodate ammendment complete as required. 3 C x 240 Sq.mm XLPE HT cable (Earthed)

90

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Above 120 sq. mm and upto 400 sq. mm

90

-

-

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 3 ½ C - 300 sq mm Aluminium

540

-

-

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 3 ½ C - 240 sq mm Aluminium

2

-

-

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 3 ½ C - 185 sq mm Aluminium

220

-

-

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 3 ½ C - 150 sq mm Aluminium

135

-

-

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 3 ½ C - 120 sq mm Aluminium

2

-

-

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 3 ½ C - 95 sq mm Aluminium

2

-

-

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 3 C - 70 sq mm Aluminium

30

-

-

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 3 ½ C - 50 sq mm Aluminium

2

-

-

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 3 ½ C- 35 sq mm Aluminium

2

-

-

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 4C- 25 sq mm Aluminium

40

-

-

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 4C- 16 sq mm Aluminium

235

-

-

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 4C- 10 sq mm Aluminium

625

-

-

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 4C- 6 sq mm Aluminium

2

-

-

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 3C- 6 sq mm Aluminium

2

-

-

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 3C- 10 sq mm Aluminium

2

-

-

... More
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 2C- 6 sq mm Aluminium

600

-

-

... More
Supply Installation of 36W LED street Light with integral control gear comprising heavy duty copper ballast , PF improvement capacitor, connection & wiring from junction box with 3# 2.5 sqmm copper wires, Mounted on existing 4.5 mtr. Pole.

8

-

-

... More
Supply, installation, Testing & commissioning of steel tubular swaged poles with bent on top along with reaquired accesseries to accomodate street light fitting complete with cast iron base plate, finial taper plug, bolts, nuts, junction box within the pole for incoming and outgoing cables (size up to 2 C x 6 Sqmm) and a 10 amps SP MCB and screws as specified in type 410 SP31 - 4.5 mtr. Long. Rate shall included the cost of inbuilt junction box (weather proof), MCB to fitting with 2.5 sq mm copper wires (2 Nos. 2.5 Sq.mm copper wire for phase & 1 No. 1.5 Sq.mm copper wire for earthing) complete with base plate made from concrete civil foundation works . The pole shall be painted with final PU Paint as required.

8

-

-

... More
Supply, Receiving and fixing in position, effecting proper connections, testing and commissioning of Gate Light including all accessories required for fixing the fixture complete as required.

4

-

-

... More
Supply, Receiving and fixing in position, effecting proper connections, testing and commissioning of Bollard Light including all accessories required for fixing the fixture complete as required.

30

-

-

... More
Supply, Receiving and fixing in position, effecting proper connections, testing and commissioning of Bollard Light including all accessories required for fixing the fixture complete as required.

30

-

-

... More
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/ GI structure of suitable strength with following components complete as required: a) Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286/ IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shal not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800VDC Input voltage range and 400V AC, three phase, 4 wire, 50Hz +/- 2.5Hz, out put voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable alongwith glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit alongwith supplying &fixing of necessary channel/ conduit lugs and other accessories etc. as required.

20

-

-

... More
4 Megapixel CMOS image sensor, H.264 & MJPEG dual-stream encoding, Max 20FPS@4MP (1920×1080) & 25/30FPS@960P (1280×960), 4mm Lens, Day/Night (ICR), Array IR Distance: 25m, (4MP HD IP SMART IR 25 Mtr Dome Camera with HD Lens)

22

-

-

... More
4 Megapixel CMOS image sensor, H.264 & MJPEG dual-stream encoding, Max 20FPS@4MP (1920×1080) & 25/30FPS@960P (1280×960), 4mm Lens Day/Night (ICR), 2DNR, AWB, AGC, BLC,Max. IR Distance: 30m, 1 Array LED , IP66, Mobile Soft: CMOB, (4MP HD IP SMART IR 30 Mtr Bullet Camera with HD Lens)

2

-

-

... More
Unmanaged Network Switches (24 port) Minimum 4/8 nos. 10/100/1000 BASE-T Ethernet Ports. Uplink port should have sufficient speed to avoid network congestion, preferably network should not be loaded more than 70% at any stage, fully IEEE 802.3 compliant,Protocols and compliances , The switch should provide all standard protocols and compliances AND Mounting Shall Be Rackmount, wall or desktop mounting options

1

-

-

... More
1 Mtr Cat 6 patch cord with 23 AWG suitable for Gigabit connection, it should be suitable to maintain the bending radius as per relevant code.

1

-

-

... More
NVR , 64 Ch. with Upto 1080p Realtime Live View, H.264/MJPEG dual codec decoding, Max 96Mbps incoming bandwidth, Support 8 SATA HDD up to 32TB, 2 USB2.0, HDMI / VGA simulta video output, Support Multi-brand network cameras, ONVIF Version 2.0 conformance, Make: Hikvision

2

-

-

... More
Supply, installation, testing and commissioning of 4TB HDD Make-WD/Seagate

2

-

-

... More
Supply, installation, testing and commissioning of Video Managment Software.Make: Flir/ Mobotix/Vicon

1

-

-

... More
Supply, installation, testing & commissioning of Client Workstation having Intel Core i5 orginal motherboard, 16 GB RAM, Video graphics card 2 GB Licensed Windows 8 Professional (64 bit) and 1 TB Hard Disk with Web camera,Printer and finger print scanner.Approved Make-HP/DELL/IBM

1

-

-

... More
Supplying, Installation,Testing & Commissioning of 40 " LED Full HD TV Resolution 1920 x 1080 ,Contrast Ratio (Typical) 5000:1,Built-in Speaker (10W + 10W), Magic Clone (to USB), Auto Source Switching & Recovery, Lamp Error Detection, Super Clear Coating, Temperature Sensor, Plug and Play (DDC2B), Pivot Display, Clock Battery, PIP/PBP, Video Wall (10x10), Image Rotation, Button Lock, HDCP Support, Smart Scheduling, Smart F/W update, Built-In MagicInfo Premium-Swith Mounting Brackets as per Technical Specification complete in all respect. Approved Make-Sony/Samsung/Panasonic

1

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of Gear Less Machine Room Less lifts, with travel speed 1.0 MPS serving different floors in the lift shaft including automatic rescue device, lift well pressurization as per detailed specification/drawing enclosed and as under:

2

-

-

... More
Capacity (kgs): 680 kg, 10 persons. Speed (mps): 1 mps Rise (m): 10 m Stops: 4 stops with (all opening on the same side) Controller type: ACD3-MRL Drive: VF Regenerative (closed loop) Power supply: 400/415 volts (3 phase AC) Operation: Full Collective Ooperation Car group: One Car (simplex) Machine: PM Gearless (located in shaft on top of guide rails) Traction media: Flat Coated Steel Belt Car finish: Stainless Steel #4(Hairline) False ceiling type: CD41 Flase ceiling finish: Stainless Steel #4(Hairline) Ventillation: Cross Flow Fan Hand Rails: Stainless Steel Mirror Finish Handrails on Rear Car Panels Flooring: Vinyl Tiles Car door finish: Stainless Steel #4(Hairline) Landing doors finish: Stainless Steel #4(Hairline) Car & hoistway door type: Central Ppening (CO) doors Door opening (W x H - mm): 800 mm W x 2000 mm H Door operator: DC door operator

-

-

-

... More
COP: COP for stops = 12 (950mm) in Stainless Steel #4(Hairline) Car position indicator: Monochrome LCD-blue background & white font dot matrix (LED) scrolling display Hall fixtures: O2000, Pan type fixture Hall fixture face plate: Stainless Steel #4 (Hairline) Hall button arrangement: LCD Monochrome type Standard features: • Anti-nuisance car call protection • Independent service (for duplex only) • Overload device • Nudging • Emergency car light unit • Infrared curtain door protection • Door time protection • Emergency alarm button • Extra door time of lobby & parking • Door open/close button • Manual rescue operation • Belt inspection drive • Auto fan cut off • Options included: • Grounding switch, • Automatic rescue operation, • Voice synthesizer, • Intercom

-

-

-

... More
Scope of work 1. Supply of materials/components/parts of elevators/escalators of Product containing features as listed above 2. Installation, testing and commissioning of elevators/ escalators at site 3. Material transportation, marine/ inland Insurance 4. Unloading of material at site 5. Supply and erection of suitable scaffolding (as per approved GAD) inside elevator shaft/escalator pit for entire installation period and dismantling/removal of the same after completion of Works. 6. Provision of all minor builders’ works (details as per GAD)

-

-

-

... More
VRF Outdoors Supply of Heat Pump Type Variable Refrigerant Flow Top Discharge Outdoor Unit with 100% DC Inverter based Scroll Compressor in each module (partial inverter compressor not allowed), can be connected to multiple Indoor Units as per specification: i) The Outdoor units shall be factory assembled weather proof casing constructed from heavy gauge mild steel with Inverter Scroll Compressor with Liquid injection facility in order to achive no deration in cooling capacity upto 45 deg C temp.. ii) The Outdoor Unit has 2 stage deep sub-cooling circuit and cross oil return technology, should be equipped with double EEV control design & four way air return heat exchanger design. iii) The Outdoor Unit should have Error code LED display for ease of operation & Each comprressor should have Oil Separator for safer operation; Automatic Oil Balancing; PCB cooled by refrigerant; Eco friendly refrigerant R-410a; Heat Pump Type & suitable for operation within the ambient temperature range of -5⁰C to 50⁰C. All indoor to indoor communication should be wireless type (no wired communication will be allowed). iv) The outdoor unit fitted with low noise aero spiral design fan with multiple speed DC motor. Outdoor ESP should be 100 Pa. Should support 1000 m piping in total, intelligent compressor back up operation, auto addressing of indoor units, automatic oil balancing, outdoor dust clean technology. Maximum outdoor noise level 65 dB(A). v) Required Power Supply :- 3Ph/440± 10% V/50Hz for each Outdoor units vi) System Warranty: 1 year from the date of Installation. Compressor Warranty: 5 years from the date of installation. vii) EER (Minimum): 3.8 or above at ARI condition 16 HP - Top Discharge with Scroll Compressor

1

-

-

... More
VRF Outdoors Supply of Heat Pump Type Variable Refrigerant Flow Top Discharge Outdoor Unit with 100% DC Inverter based Scroll Compressor in each module (partial inverter compressor not allowed), can be connected to multiple Indoor Units as per specification: i) The Outdoor units shall be factory assembled weather proof casing constructed from heavy gauge mild steel with Inverter Scroll Compressor with Liquid injection facility in order to achive no deration in cooling capacity upto 45 deg C temp.. ii) The Outdoor Unit has 2 stage deep sub-cooling circuit and cross oil return technology, should be equipped with double EEV control design & four way air return heat exchanger design. iii) The Outdoor Unit should have Error code LED display for ease of operation & Each comprressor should have Oil Separator for safer operation; Automatic Oil Balancing; PCB cooled by refrigerant; Eco friendly refrigerant R-410a; Heat Pump Type & suitable for operation within the ambient temperature range of -5⁰C to 50⁰C. All indoor to indoor communication should be wireless type (no wired communication will be allowed). iv) The outdoor unit fitted with low noise aero spiral design fan with multiple speed DC motor. Outdoor ESP should be 100 Pa. Should support 1000 m piping in total, intelligent compressor back up operation, auto addressing of indoor units, automatic oil balancing, outdoor dust clean technology. Maximum outdoor noise level 65 dB(A). v) Required Power Supply :- 3Ph/440± 10% V/50Hz for each Outdoor units vi) System Warranty: 1 year from the date of Installation. Compressor Warranty: 5 years from the date of installation. vii) EER (Minimum): 3.8 or above at ARI condition 26 HP - Top Discharge with Scroll Compressor

1

-

-

... More
VRF Indoors Supply of VRF Type Indoor Unit - Ceiling Mounted Round Way Cassette AC Equipped with Pure Copper, Evaporator Coils & will be configured with the ablove mentioned VRF Outdoor Units. The Indoor Units should be Complete with Electronic Expansion Valve with AC Fan Motor, Controls,In-Built Drain Pump with Insulated Drain Pan & LCD Display on Indoor Unit. Air louvers should be able to controll invidually in all 4 directions with the help of controller. The Indoor Unit should have both Control Option - Corded & Cordless Remote Control. Required Power Supply :- 1Ph/200± 10% V/50Hz for each indoor units. CFM: 580 - Round Way Cassette AC with Panel, Noise level (at low air speed): 35 dB(A)

2

-

-

... More
VRF Indoors Supply of VRF Type Indoor Unit - Ceiling Mounted Round Way Cassette AC Equipped with Pure Copper, Evaporator Coils & will be configured with the ablove mentioned VRF Outdoor Units. The Indoor Units should be Complete with Electronic Expansion Valve with AC Fan Motor, Controls,In-Built Drain Pump with Insulated Drain Pan & LCD Display on Indoor Unit. Air louvers should be able to controll invidually in all 4 directions with the help of controller. The Indoor Unit should have both Control Option - Corded & Cordless Remote Control. Required Power Supply :- 1Ph/200± 10% V/50Hz for each indoor units. CFM: 810 - Round Way Cassette AC with Panel, Noise level (at low air speed): 35 dB(A)

1

-

-

... More
VRF Indoors Supply of VRF Type Indoor Unit - Ceiling Mounted Round Way Cassette AC Equipped with Pure Copper, Evaporator Coils & will be configured with the ablove mentioned VRF Outdoor Units. The Indoor Units should be Complete with Electronic Expansion Valve with AC Fan Motor, Controls,In-Built Drain Pump with Insulated Drain Pan & LCD Display on Indoor Unit. Air louvers should be able to controll invidually in all 4 directions with the help of controller. The Indoor Unit should have both Control Option - Corded & Cordless Remote Control. Required Power Supply :- 1Ph/200± 10% V/50Hz for each indoor units. CFM: 1180 - Round Way Cassette AC with Panel, Noise level (at low air speed): 37 dB(A)

4

-

-

... More
VRF Indoors Supply of VRF Type Indoor Unit - Ceiling Mounted Round Way Cassette AC Equipped with Pure Copper, Evaporator Coils & will be configured with the ablove mentioned VRF Outdoor Units. The Indoor Units should be Complete with Electronic Expansion Valve with AC Fan Motor, Controls,In-Built Drain Pump with Insulated Drain Pan & LCD Display on Indoor Unit. Air louvers should be able to controll invidually in all 4 directions with the help of controller. The Indoor Unit should have both Control Option - Corded & Cordless Remote Control. Required Power Supply :- 1Ph/200± 10% V/50Hz for each indoor units. CFM: 1210 - Round Way Cassette AC with Panel, Noise level (at low air speed): 37 dB(A)

6

-

-

... More
Controllers Supply of Cordless Controllers for all indoor units.

13

-

-

... More
Inverter Ductable Units with following specifications a) Capacity: 4400 CFM b) Power Input: 3-ph/50 Hz/415V c) Compressor: 100% DC inverter scroll/ rotary d) External Static Pressure: 20 mm WC e) ISEER: 3.5 or above at ARI condition f) The unit should be equiped with UVGI Technology which should be compliant with safety standards - CSIR/ROHS/ISO/UL/ETL/SGS/CE. UVGI Emitters with ultra duct modules capable of sterilizing with powerful UVC light & kills up to 90% of surface germs and bacteria consisting of a) Germicidal UV Lamp with strong emmission line wavelength of 200 to 300 nm, 1-ph/220±10%/50Hz, AHU/Blower interlocked power supply from AHU to UVGI Panel b) Reflector c) High-efficiency UV ballast enclosed within IP54 rated enclosure d) Lamp Harness e) Basic mounting hardware

5

-

-

... More
g) Indoor unit shall be factory assembled coil section with 4-Row Deep Coil, Hydrophilic Aluminium Fin, Fin Spacing 1.4 mm complete with Copper Tube (Copper Tubes should be of standards - JIS 3300:1997/ ASTM B 280-03/ ASTM B 68), Tube Pitch x Row Pitch - 21 mm × 18 mm, Tube Outside Dia - ø7, Tube Type - Inner Grooved, Number of circuits - 9. DC fan motor drive set, cetrifugal type, 1600 RPM. The unit must be with washable flange type air purification filters. EEV should be inbuilt. Outdoor unit shall be factory assembled weather proof casing constructed from heavy gauge mild steel with error code diagnosis function for ease of operation, shall be complete with Phase sequence correction technology. Refrigeration chamber and Electronic chamber should be separate and shall be with 2 nos. of Fan Motor design Outdoor coil section with 2-Row Deep Coil, Hydrophilic Aluminium Fin, Fin Spacing 1.4 mm complete with Copper Tube (Copper Tubes should be of standards - JIS 3300:1997/ ASTM B 280-03/ ASTM B 68), Tube Pitch x Row Pitch - 21 mm × 18 mm, Tube Outside Dia - ø7, Tube Type - Inner Grooved, Number of circuits - 12.

-

-

-

... More
h) Maximum Noise Level Indoor: 50 dB (at high speed) i) Maximum Noise Level Outdoor: 65 dB j) Refrigerant: R410a k)Controller: Corded with Touch Screen Operation & Display l)The system should be suitable for operation up to 60⁰C m) The outdoor units shall be complete with all safety devices, HP, LP switches & overload protection, voltage fluctuation of 15% minimum

-

-

-

... More
Central Controller Supply of Intelligent Touch Screen LCD Display type Manager (Controller) to hook up all VRF Indoor units and ductable indoor units as mentioned above. Controller shall act as Master Controller for controlling of cooling/heating modes of outdoor units and their associated indoor units. The controller shall have set point range unit facility also. Controller shall be suitable for ON/OFF and Temperature Control of areas including scheduling, malfunction and status display.

1

-

-

... More
Supply of Y-Joints or Branch Pipes Supply of Y-Joints for Indoor units

12

-

-

... More
Supply of Y-Joints or Branch Pipes Supply of Y-Joints for Outdoor units

1

-

-

... More
Refrigerant Piping Works Supply, Installation, Testing & Commissioning of refrigerant piping for the air conditioning system, shall be constructed from annealed pipes and hard drawn copper refrigerant pipes with copper fittings including tubular 19 mm thick (O Class) Nitrile Insulation with aluminium foil over refrigerant pipes. It also includes supports to hang the copper pipes. Pipe Size - 6.35 mm

40

-

-

... More
Refrigerant Piping Works Supply, Installation, Testing & Commissioning of refrigerant piping for the air conditioning system, shall be constructed from annealed pipes and hard drawn copper refrigerant pipes with copper fittings including tubular 19 mm thick (O Class) Nitrile Insulation with aluminium foil over refrigerant pipes. It also includes supports to hang the copper pipes. Pipe Size - 9.52 mm

80

-

-

... More
Refrigerant Piping Works Supply, Installation, Testing & Commissioning of refrigerant piping for the air conditioning system, shall be constructed from annealed pipes and hard drawn copper refrigerant pipes with copper fittings including tubular 19 mm thick (O Class) Nitrile Insulation with aluminium foil over refrigerant pipes. It also includes supports to hang the copper pipes. Pipe Size - 12.7 mm

50

-

-

... More
Refrigerant Piping Works Supply, Installation, Testing & Commissioning of refrigerant piping for the air conditioning system, shall be constructed from annealed pipes and hard drawn copper refrigerant pipes with copper fittings including tubular 19 mm thick (O Class) Nitrile Insulation with aluminium foil over refrigerant pipes. It also includes supports to hang the copper pipes. Pipe Size - 15.88 mm

60

-

-

... More
Refrigerant Piping Works Supply, Installation, Testing & Commissioning of refrigerant piping for the air conditioning system, shall be constructed from annealed pipes and hard drawn copper refrigerant pipes with copper fittings including tubular 19 mm thick (O Class) Nitrile Insulation with aluminium foil over refrigerant pipes. It also includes supports to hang the copper pipes. Pipe Size - 19.05 mm

55

-

-

... More
Refrigerant Piping Works Supply, Installation, Testing & Commissioning of refrigerant piping for the air conditioning system, shall be constructed from annealed pipes and hard drawn copper refrigerant pipes with copper fittings including tubular 19 mm thick (O Class) Nitrile Insulation with aluminium foil over refrigerant pipes. It also includes supports to hang the copper pipes. Pipe Size - 22.23 mm

20

-

-

... More
Refrigerant Piping Works Supply, Installation, Testing & Commissioning of refrigerant piping for the air conditioning system, shall be constructed from annealed pipes and hard drawn copper refrigerant pipes with copper fittings including tubular 19 mm thick (O Class) Nitrile Insulation with aluminium foil over refrigerant pipes. It also includes supports to hang the copper pipes. Pipe Size - 25.4 mm

20

-

-

... More
Refrigerant Piping Works Supply, Installation, Testing & Commissioning of refrigerant piping for the air conditioning system, shall be constructed from annealed pipes and hard drawn copper refrigerant pipes with copper fittings including tubular 19 mm thick (O Class) Nitrile Insulation with aluminium foil over refrigerant pipes. It also includes supports to hang the copper pipes. Pipe Size - 28.58 mm

45

-

-

... More
Refrigerant Piping Works Supply, Installation, Testing & Commissioning of refrigerant piping for the air conditioning system, shall be constructed from annealed pipes and hard drawn copper refrigerant pipes with copper fittings including tubular 19 mm thick (O Class) Nitrile Insulation with aluminium foil over refrigerant pipes. It also includes supports to hang the copper pipes. Pipe Size - 31.80 mm

20

-

-

... More
Drain Piping Supply,installation,testing and commissioning of PVC Condensate Drain Piping with tubular 9 mm thick nitrile insulation (O Class) over it Pipe Size - 25mm

190

-

-

... More
Drain Piping Supply,installation,testing and commissioning of PVC Condensate Drain Piping with tubular 9 mm thick nitrile insulation (O Class) over it Pipe Size - 40mm

65

-

-

... More
Cables Supply, Installation of copper control cable for Ductable AC, passed under PVC conduit of adequate size (FRLS Type)

230

-

-

... More
Air Distribution System Supply ,Fabrication, Installation & Testing of GI Sheet Metal Ducts and including bends for air distribution system, necessary supports, flexible hangers with isolators, nut bolts, gasket,and vanes etc. duct to be fabricated/ erected. Ducting - 22 G

60

-

-

... More
Air Distribution System Supply ,Fabrication, Installation & Testing of GI Sheet Metal Ducts and including bends for air distribution system, necessary supports, flexible hangers with isolators, nut bolts, gasket,and vanes etc. duct to be fabricated/ erected. Ducting - 24 G

400

-

-

... More
Supply, Fabrication, Installation & Testing of Fire Retardant type Flexible Canvas Connection with aluminium frame

5

-

-

... More
Insulation Supply, Installation & Testing of Acoustic lining with Nitrile Rubber insulation with 15 mm thickness (O Class).

60

-

-

... More
Insulation Supply,Installation & Testing of Closed cell Elastomeric Nitrile rubber Thermal insulation with pre coated aluminium foil on Supply air duct & Return air duct in return air path with 13 mm thickness.

400

-

-

... More
Supply, installation, testing and balancing of powder coated extruded aluminium Grills/ Diffusers as per drawings and specifications. For supply air

40

-

-

... More
Supply, installation, testing and balancing of powder coated extruded aluminium Grills/ Diffusers as per drawings and specifications. For return air

60

-

-

... More
SITC of stands for Outdoor Units (Concrete/MS structure) MS Stand for MRV for Outdoor Units

7

-

-

... More
Extra Refrigerants Supply of Extra Refrigerants for commissioning the system

100

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia

80

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia

20

-

-

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel

8

-

-

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required

14

-

-

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 mtr

14

-

-

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :certification (Two per each single landing valve ). Stainless Steel (Grade 304)

28

-

-

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling Stainless Steel (Grade 304)

8

-

-

... More
Providing and fixing standard fireman's axe with heavy insulated rubber handle tested for 20000 volts confirming to IS:926.

8

-

-

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe

2

-

-

... More
Providing and fixing gunmetal single acting air release valve with screwed inlet 25 mm dia as per IS 12992 rated for 20 Kg/Sq.cm

4

-

-

... More
Providing and fixing SS/ Brass ball valve full bore type tested for 20kg/cm2 with lever and screwed female ends. 25 mm dia full bore type

21

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia

6

-

-

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia

5

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 150 mm dia

80

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia

20

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia

5

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 65 mm dia

65

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 50 mm dia

115

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :

75

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 32 mm dia

70

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 25 mm dia

132

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 20 mm dia

455

-

-

... More
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories: Pendent type

369

-

-

... More
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.

369

-

-

... More
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required 1000 mm

239

-

-

... More
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required 1500 mm

130

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 65 mm dia

4

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 150 mm dia

4

-

-

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 65 mm dia

4

-

-

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 150 mm dia

5

-

-

... More
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 65mm dia

4

-

-

... More
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 150 mm dia

4

-

-

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes 200 mm. dia (wall thickness = 6.3 mm)

80

-

-

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes 150 mm. Dia

4

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia NB

6

-

-

... More
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel

6

-

-

... More
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. 2280 lpm at 70 m Head

1

-

-

... More
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of 2280 lpm at 70 m Head

1

-

-

... More
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered 180 lpm at 56 m Head

1

-

-

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade

1

-

-

... More
SITC of Pressure gauge Supply, installation, testing & commissioning of 100 mm dia Bourden type, Stainless Steel dial type glycerine filled pressure gauge including brass isolation valve and pipe having caliberation of 0-16 Kg/cm2.

3

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 200 mm dia

30

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 150 mm dia

20

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia

10

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia

10

-

-

... More
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 200 mm dia

2

-

-

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required: 80 mm dia.

1

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 200 mm dia with lever

2

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 150mm dia with lever

2

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia with lever

1

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 80mm dia with lever

1

-

-

... More
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.

3

-

-

... More
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100mm dia

1

-

-

... More
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 200mm dia

2

-

-

... More
CONTROL PANELS Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required: Assembly system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel before fabrication. Cadmium Plated hardware shall be used in fabrication of panels. Quoted rates shall inclusive of cables, cable trays, earthing (in accordance to specification) with earthing from panel to each motor / equipment. (Components make: L&T, Schneider, ABB, Siemens)

1

-

-

... More
Incomings 400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip Indicating lamps Set of Copper Bus Bar 500A Outgoings (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump 200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey Pump 100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.

-

-

-

... More
Diesel Engine Control Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempt starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specifications.

-

-

-

... More
Providing and fixing mechanical foam type fire extingushers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cms long high pressure discharge hose , discharge nozzle ,suspension brakcet, ISI marked as per IS:10204 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges. Capacity 9 kg (Pump Room & DG set)

1

-

-

... More
Providing and fixing stored pressure ABC Fire Extinguisher consisting of welded M.S. cylinderical body, squeeze lever discharge valve 30 cms long high pressure discharge hose, discharge nozzle, suspension braket, ISI marked as per IS:13849 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges. Capacity 6 Kg

12

-

-

... More
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylinderical body,squeeze lever discharge valve fitted with internal dischargetube,30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners Capacity 4.5 kg.

1

-

-

... More
Providing and fixing at approved location approved make 4 nos. fire buckets of 24 gauge galvanized steel, painted white inside and red outside and black on the bottom, inscribed with letters ”FIRE” in black and gold including stand fabricated out of sheet metal (16 gauge) shade, platform and associated civil works, painting etc as approved

1

-

-

... More
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel.

1

-

-

... More
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.

84

-

-

... More
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.

2

-

-

... More
Supplying, installation, testing & commissioning of addressable fire control module complete as required.

8

-

-

... More
Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required.

3

-

-

... More
Supplying, installation, testing & commissioning of addressable manual call point complete as required.

9

-

-

... More
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.

9

-

-

... More
CABLING & WIRING Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

500

-

-

... More
CEILING TREATMENT Providing & Fixing of (Moisture Resistant Gypsum board Ceiling) All height with necessary GI framing as explained under Gypsum ceiling. As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. Features & Properties: • Good sound insulation performance • Hydrophobic boards impregnated against absorption of moisture • High fire protection performance • Contains glass fibre additives to maintain the integrity of board for longer time periods than standard boards when exposed to fire. • A material that breathes and balances room climate and humidity levels • Environment friendly • Limitless design options The tapered and square edges of the boards are jointed and finished to a flush finish with requisite jointing compound paper tapes finishes and primer suitable for gypsum plaster boards as per mentioned make with 12.5mm thickness. including two or more coats of plastic emulsion paint to a smooth finish finished surface area of Gypsum board Ceiling. with cove desigen. Work complete in all respect as per the drawing& design to the satisfaction of Engineer in-charge or Project Officer. Approved Brands: USG BORAL(Lafarge) / Saint Gobain / (Gypcore) / Indain Gupsum

142.19

-

-

... More
Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling System) All height with necessary GI framing As per Architectural Drawings, work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. Features & Properties: Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling System with tiles with 15mm Exposed GRID as per manufacturer specification. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9, Light Reflectance ≥85%, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm. The tile shall be laid on 38 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 14 Kgs/M2. The T Sections have a Galvanizing of 90 grams per M2. INSTALLATION: To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit using suspension system (as per specifications) at 1200mm centre to centre. The First/Last suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centres.SUSPENSION SYSTEM accessories consisting of M6 Anchor Fasteners with Vertical Hangers made of Galvanised steel of size 26 x 26 x 25 x 1.2mm with a Galvanised Thickness of 80gsm, A pre Straightened Hanger wire of dia 2.68 mm of 1.83 m length., thickness of 80gsm and a tensile strength of 344-413 MPa, along with Adjustable hook clips of 0.8mm thick, galvanised spring steel for 2.68 mm with a minimum pull strength of 110 kg. The adjustable clip also consists of a 3.5 mm aquiline wire to be used with the main runner. Approved Brands: Armstrong / Gyproc by Saint-Gobain / Pro-Acoustics Decosonic

231.41

-

-

... More
SIDE WALLS TREATMENT Wooden Grooved & perforated Acoustical Panels Used On Auditorium Side Walls Providing & fixing of customized grooved & perforated wooden Medium Density Fibreboard panel to reduce echoes by trapping and diffracting sound in the grooves and perforation found on the surface backing with black fleece. As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete to achive NRC 0.76 (Noise Reduction Co-efficient) with 50mm Rockwool, The sound that passes through the perforation is further absorbed by Rockwool, which reduces reverberation in the room. Smaller grooves are better at attenuating high frequency sounds, whereas larger grooves are better at controlling low frequency sounds with requirted lineal perforation on side wall as per simulated drawings & designs. The panels shall be Non FR grade with melamine laminate panels 2440mm x130mm x 18mm with 2.5mm groove at 14mm pitch, Tongue and Groove edges for seamless mounting having density of 400kg/m3, The Panel is fixed by using GI Framework spaced at 600mm centres @ 12 mm wooden ply strips framework spaced at 400mm centers with suitable hardware and the system is backline with 50 mm insulation and along with all accessories. Continue installing rows of panels by inserting screw & plugs into the groove of the wooden panel and progressively installing the panel into the next keel till the actual height is achieved. Finish off the edges using wooden moulding of matching colour. The panelling work shall be done in all respects as per detailed drawings. The Work complete in all respect as per the drawing to the satisfaction of Engineer in-charge or Project Officer. Approved Brands: Pro-Acoustics / Action Tesa / Green / Century

264.41

-

-

... More
ACOUSTICAL NATURAL RUBBER WOOD PANELS Providing & fixing Acoustical Natural Rubber Wood Wall Paneling as per Architectural Drawings. Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete The work will also include all cost for creation of niches for installation of AV equiments and electrical fittings wherever required. The polish shade and finish will be as per consultant. The cost will include all accessories or any material which may be required to complete the work as per specification, drawings and as directed by the consultant.Framing: Framework consisting of 50mmx 0.5 mm thick Drywall stud channel at 450mm intervals with track channels at bottom and top including all accessories from materials that comply with ASTM C645 and A653, with a minimum G60 coating or equivalent filled with 50 theic polyster wadding@ 1000 gsm environment and human health friendly to be held in position with chicken mesh of 18mm 24SWG.Front Face Finishing Material: 12mm natural rubber wood plank size & design as per of architect/consultant choice with 8 mm groove to be pasted on top of 8mm perfoarted MDF baord with our without group finish fixed over a GI Stud framework. The rubber wood will be finished with Mat/ Glossy Polish complete as per consultants drawings & instructions.

29.93

-

-

... More
Stretch Fabric Acoustical Wall System Used On Auditorium Side Walls Providing and Fixing of Fabric acoustic wall and ceiling treatment system as per architectural drawings to achive customized design, Stretch fabric panelsa are designed for acoustic performance and visual enhancements, Panles combines beauty and functionality, creating environments that appeal to all senses. In addition to eliminating unwanted noise and reverberation inside Auditorium above 8ft height: As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete Stretch fabric panels fixed on flexible track profiles secure and frame fabric finish with excellent for sound control applications and is also a beautiful wall covering, enhancing the décor and the sound of installations, almost any panel size can be created in side Auditorium on G.I studs 2400mm X 50mm web flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120GSM zinc coating specially designed for Acoustic vibration management and long life with a backing 50mm thick Rock wool @48kg density insulation intact with chicken mess wires NRC up to .90. To be mechanically fastened on the G.I Studs. Then 12mm Vinyl tracks are screw fixed on to the 12 mm Ply and Acoustics panel’s .Then the fabric is stretched over the Vinyl tracks. The installed system should provide NRC OF 1.00.Fabric colour as per Architect choice-Ref attached specifications for more details. The system to be installed on G.I studs 600x600mm centre to centre 2400mm X 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120GSM zinc coating specially designed for Acoustic vibration management and long life with a backing of 50mm thick, 1000 GSM Rock wool tested as per Fire Retardant ASTMD 635-1991 /Insulation and IS 15061-2002 for excellent results. Work complete in all respect as per the drawing to the satisfaction of Engineer in-charge or Project Officer. Approved Brands: Nexgen / Innovative / Responce

281.6

-

-

... More
Stage Procenium Arc "Structure In Front Of Stage" The proscenium of a stage is one of the divisions of the stage, As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete A structure in front of the stage that frames the action of the play. It can be square or arched, and the stage curtain is generally directly behind it."picture frame" placed around the front of an end stage. the invisible barrier that separates the stage from the audience and through which the audience watches the action. The “Arch acts like a picture frame through which the action can be seen. The picture above shows the Proscenium Arch of the Stage. A proscenium arch creates a "window" around the scenery and performers, the advantages are that it gives everyone in the audience a good view because the performers need only focus on one direction rather than continually moving around the stage to give a good view from all sides. A proscenium theatre layout also simplifies the hiding and obscuring of objects from the audience's view. Anything that is not meant to be seen is simply placed outside the "window" created by the proscenium arch, either in the wings or in the fly space above the stage. Arch serves as the frame into which the audience observes from a more or less unified angle the events taking place upon the stage during a theatrical performance. Providing & fixing Stage Proescinium: to be fabricated on site as per proposed design Outer MS tubler framemade with 50mm X 50mm and inner Joints with 25mm X 25mm infill with 48mm thick 40kg/cum density Rockwool insulation padding. front side fixing on 12mm Water Proof Ply. Finishing with Metal Aluminium composit panel 4mm total thickness with top and bottom coil of 0.5mm thick AA3105 Alloy grade (Hindalco) produced from direct chill process and following EN 485-2. The top and bottom aluminium coil should be coated in( Rustic Matt Finish ) with lead free PVDF (Polyvinyl Diene Fluoride) paint of 70:30 ratio by Double Coat Double Bake method followingAAMA2605. The core should be mineral core with minimum 70% inorganic matter passing resistance to fire ASTM E119 for 2 hours and reaction to fire EN13501-1 Class B S1 D0.as per approved shade, fixing with adesive. Work complete in all respect as per the drawing to the satisfaction of Engineer in-charge or Project Officer.

57.62

-

-

... More
Acoustical Stage Wooden Flooring Providing and Fixing Stage Wooden Flooring: As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete Providing and fixing 75mm to 90mm X 20mm to 18mm thick in random length, 2nd class teak wood planks flooring with tongue and groove joints on a layer of 19 mm thick BWR grade ply of approved make and manufacture, fixed to hardwood joint 62mmX 62mm at 600 mm c/c in one direction and 62 X 62 mm hard wood battens 600mm c/c on other direction, interlocked frames . the framework Hardwood joint resiliently supported on 12mm Thickness X 100MM Width X 100 MM Length ANTI VIBRATION RUBBER PAD BOTH SIDE GRIP with Specific Gravity: 1.60g/cm3(+/-.05), Hardness : 70 (+/- 5) Shore A, Tensile Strength: 30 kg/cm2 (min), Elongation: 250% (min) Rubber Pads, the framework to be filled with 50mm thick Insulation Wool resin bonded insulation of density 24kg/cum. PU polishing of teakwood on the exposed surface: In horizontal/vertical plane (rate for flooring shall include providing additional framework required for housing microphone and power outlet junction - signal & Popup Stage boxes, If required providing and fixing hinged 18mm thick teakwood cover for the junction boxes. As per Design & Drawing Work complete in all respect as per the drawing to the satisfaction of Engineer in-charge or Project Officer.

167

-

-

... More
Wooden Fire Cum Acoustical Sound Reducing Doors Providing & fixing Acoustical sound reducing Doors with compatable Wooden Door Frame made of hard wood of section 150 x 90 mm with Acoustic strip of section 10 x 4 mm completely finished with two coat of Primer. As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete 75mm thick asbestos free composite fire cum smoke check wooden shutter of 38db acoustic cum 120 min fire resistant rating confirming to BS:476 part-22 & IS:3614 part-2 comprising of two 12mm thick noncombustible boards, a 100% without asbestos, brucite and meerschaum, having density not less then 1150Kg/M3 and thermal conductive 0.14W/m*k sandwiching 33 mm thick fire resistance insulation filler and faced with 4 mm commercial on both side with heat activated intumescent fire seal strip of size 10 X 4mm mounted in the grooves of hardwood lipping on all three sides except bottom. a) Finished with 1 mm Thick Laminate. b) Finished with 4 mm Thick Veenear. c) Finished with 2 Coat of Fire Retardant Primer Approved Brands: PRO-ACOUSTICS / NAVAIR / Envirotech / BHAWANI FIRE

26.58

-

-

... More
HARDWARE REQUIRED • 304 grade SS ball bearing hinges (100 X 75 X 2.5mm) (Make: Garg) • Door closer (Make: Briton) • Acoustic Side Seal (Make: Enviroseal Acoustic) • Bottom Drop Down Seal (950mm Max) • Acoustic Center Seal • 120min fire rated cleared wired glass (200X300X6mm) (Make:Pilkington) • Double Leaf Panic Bar (Make: Dorma/ Ozone/ Hardwyn) • Mortise lock with lever handle with 80 mm cylinder (Make: Hardwyn/Briton) • SS Tower bolt (10”) • 304 Grade SS Door Handle (Make: Ozone/ Hardwyn/Briton/Dorma)

-

-

-

... More
Vinyl Carpet Acoustical Carpet with Stain, water & Oil resistanton on all passage Providing and fixing of Sound Absorbent Anti bacterial Woven vinyl floorings with roll dimensions of As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete 1.8 meters width and length of 20 m`ters with Stain, water & Oil resistant Tiles size as per company standard should be approved by engineer in charge. 2.50-2.80 mm thickness to laid on hard, levelled, smooth and moisture free sub floor. Woven Vinyl flooring should have traffic classification 33 and weight of 2.7-3.5 kg/m2. Flooring should have caster chair EN-985 tested with color fastness of more than 6. It shoukld be ASTME662 qualified on Smoke density test. Product should be fire rating of the product should be Bfl-S1. Any Joints in flooring rolls should be sealed with cold welding. As per approved shade and colour as per the satisfaction of the engineer in charge. Approved Brands: Vibrant / Bolon / Nox

431.6

-

-

... More
Providing & Fixing of Stair edging trims, or angles, provide a safe and professional finish to the front of steps. As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete When installed they conceal the exposed edges of step floorcoverings and stair nosings.Provides Slip resistance thereby ensuring adherence to safety norms. Where steps are covered with carpet, stair nosing ensures that the carpet stays in place. There are two stair edging trim options in aluminium or UPVC with thickness of 30-60 mm, 45-55 mm, they solve the purpose of Aesthetics, maintainance & Safety.

62.79

-

-

... More
Providing and fixing of 25-50 mm thick wooden nosing made out of 2nd class teak to finish staircases and edges in flush or overlap. As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete They are designed to take the brunt of foot traffic while maintaining each step’s beauty. Flush noses are used through glue / nail-down methods. They are often nailed with shoe,saddle & Quarter round shape leaving smooth and finshed surface, They often contribute to low maintainance and extended life span of the material keeping the edges safe and in alignment.

27.43

-

-

... More
Providing and Fixing of Side Skirting Wooden Beading As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete Installation on side skirting & Molding 100mmX10/8mm as per requried finnishing with melamine polishing. Work complete in all respect as per the drawing to the satisfaction of Engineer in-charge or Project Officer.

264.26

-

-

... More
Horizontal MAIN CURTAIN: As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete The complete automatically motorized Stage curtain system with additional modified Gearbox fitted with sealed bearings self-lubricating centre split overlapped curtains both sides opening fully automatic Stage Curtain fixing steel rails track made out of 450 GSM made out of, double gathering Velvet, Molfin, Mokel or Hitech Fabric Curtain cloth drapery horizontal sliding arrangement complete with fixing rails, brackets and motorized operation complete with runners, master runners, pullies, 3mm steel wire rope, 1 HP Motor (Crompton or Godrej) 2 Nos Air Breaker Contractors (L&T/SIEMENS), 2nos. Micro Switches for auto stop, 3 nos push buttons for forward. All rollers are sliding with roller clamp, The curtain should be half of full width operated from control panel with control switches. Provision is for fully automatic operation only. Height 24'-0" , Length 46'-6" ( Area =1116Sq.Ft.) “Decorative fancy gota embroidered three layer golden border gota Patti on bottom of front Curtain” FABRIC SPECIFICATION : 450 GSM VELVET, Shade and fabric approved by Engineer in Charge or enduser Fabric Make : Innovative, Response or Nexgen Specified Make: Canara / Stage Works / Illumitex

1

-

-

... More
Horizontal Middle Curtain: As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete The complete automatically motorized Stage curtain system with additional modified Gearbox fitted with sealed bearings self-lubricating centre split overlapped curtains both sides opening fully automatic Stage Curtain fixing steel rails track made out of 450 GSM made out of, double gathering Velvet, Molfin, Mokel or Hitech Fabric Curtain cloth drapery horizontal sliding arrangement complete with fixing rails, brackets and motorized operation complete with runners, master runners, pullies, 3mm steel wire rope, 1 HP Motor (Crompton or Godrej) 2 Nos Air Breaker Contractors (L&T/SIEMENS), 2nos. Micro Switches for auto stop, 3 nos push buttons for forward. All rollers are sliding with roller clamp, The curtain should be half of full width operated from control panel with control switches. Provision is for fully automatic operation only. Height 24'-0" , Length 46'-6" ( Area =1116Sq.Ft.) FABRIC SPECIFICATION : 450 GSM VELVET, Shade and fabric approved by Engineer in Charge or enduser Fabric Make : Innovative, Response or Nexgen Specified Make: Canara / Stage Works / Illumitex

1

-

-

... More
Horizontal REAR CURTAIN: As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete The complete automatically motorized Stage curtain system with additional modified Gearbox fitted with sealed bearings self-lubricating centre split overlapped curtains both sides opening fully automatic Stage Curtain fixing steel rails track made out of 450 GSM made out of, double gathering Velvet, Molfin, Mokel or Hitech Fabric Curtain cloth drapery horizontal sliding arrangement complete with fixing rails, brackets and motorized operation complete with runners, master runners, pullies, 3mm steel wire rope, 1 HP Motor (Crompton or Godrej) 2 Nos Air Breaker Contractors (L&T/SIEMENS), 2nos. Micro Switches for auto stop, 3 nos push buttons for forward. All rollers are sliding with roller clamp, The curtain should be half of full width operated from control panel with control switches. Provision is for fully automatic operation only. Height 24'-0" , Length 46'-6" ( Area =1116Sq.Ft.) FABRIC SPECIFICATION : 450 GSM VELVET, Shade and fabric approved by Engineer in Charge or enduser Fabric Make : Innovative, Response or Nexgen Specified Make: Canara / Stage Works / Illumitex

1

-

-

... More
STAGE FRILLS: As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete made out of, 450 GSM double gathering glazed Velvet, Molfin, Mokel or Hitech Fabric; to be installed above the stage on 28mm dia GI pipe adjustable at position according to stage positioning plan; Cloth material of desired shade with Stitching. FABRIC SPECIFICATION : 450 GSM VELVET, Shade and fabric approved by Engineer in Charge or enduser Fabric Make : Innovative, Response or Nexgen Specified Make: Canara / Stage Works / Illumitex

4

-

-

... More
STAGE WINGS: As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete Providing and fixing of cloth wings made out of black glazed 450 GSM Velvet, Molfin, Mokel or Hitech fabric fixed on 32mm Pivoted Rotatable Bar Fixed with thick commercial plywood fixed on one side of Frame work with sliding assembly on top supported from ecisting structure & wheels on bottom for free movement. FABRIC SPECIFICATION : 450 GSM VELVET, Shade and fabric approved by Engineer in Charge or enduser Fabric Make : Innovative, Response or Nexgen Specified Make: Canara / Stage Works / Illumitex

6

-

-

... More
GRID STRUCTURE: As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete Customized Fabrication of Main Overhead Grid over Stage using 50mm x 50mm x 5mm MS A Iron, in a 2ft.x2ft. Section & suspended from the ceiling “37ft X 25ft “ Grid dimension.

3500

-

-

... More
CYCLORAMA FRAME WITH 1.8 Power HIGH GAIN GRANDVIEW MATT WHITE PROJECTOR SCREEN: As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete Cyclorama frame with Grandview high-gain matt white screen duly stretched on large tubular MS pipe frame made out of 32 mm die fix frame for projection screen: Cyclorama Screen that is manufactured using quality assured raw components and advanced technologies. Hi-Gain Cyclorama screen has been installed for Slide / film projection in a multipurpose auditorium, besides using it as colour wash or for pattern projection for stage performance. Cyclorama lights are directed to fall on this screen to colour wash it from top as well as Moving Heads installed on the First Intelligent Bar provide infinite pattern and depth to the screen. High-gain front projection screen with four inch black masking studs on all sides. HD fabric Material is designed for DLP and LCD Cinema Projectors. This surface is the best choice when using a low contrast ratio projectors with a high definition video source. High Contrast is perfect for use in HD Cinema applications Screen Surface is safely washable with mild soap and water. Height =20' Cyclorama Frame Size =30ft. Specified Make: Canara / Stage Works / Illumitex

1

-

-

... More
Cable Trays: As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete Cable trays of size 4”x2”- 16 gauge sheet CRC, for wiring of stage lights & sound system and enrooted to control room. Specified Make: Canara / Stage Works / Illumitex

100

-

-

... More
Fabrication on Stage & Catwalk As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete for holding entire fixtures, lights, wings, light bar and other accessories, made from 40X40X6mm angle with wire mash1” square 3ft width with flat & angle iron Specified Make: Canara / Stage Works / Illumitex

1500

-

-

... More
Supply, Installation, Laying, Testing & Commissioning of Data Signal Cabling for Remoter Curtains: As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete Using 4-core PVC insulated multistranded cable to transmit Signal through curtain drives . high speed data cable designed for EIA485 ; lowcapacitance, twisted pair shielded ; FHDPE insulation, for interlinking splitter to Control Room with required connectors (1 main +1 backup)

3

-

-

... More
MODULAR WIRED FIXED HEAVY-DUTY STAGE LIGHTING BAR SYSTEM MAKES RIGGING LIGHTS QUICK AND EASY WITH POWER OUTLETS BUILT INTO THE BAR FOR LIGHTING APPLICATIONS.: Over Head Light Bar fabricated with Steel Rectangular Tube 4" x 4" x 16 Gauge dia pipe of full length interlocked with 2"inch square pipe lincked with 2"inch round pipe for trussing with adequate clamps, bars can be linked together side by side to form a single rigid bar, bar can be hung from wire ropes, chains or hung from an existing grid, this lighting bar painted in side, outside with zinc chromate primer finally coated with black quick drying enamel paint to mounting for stage lighting, which is suspended from bars above the stage to focus/Wash the stage. Approved Brands: Canara/ Stage Works/ Illumitex/ Effectron

3

-

-

... More
Truss FOH “FRONT OF HOUSE” LIGHT BAR: 40NB dia pipe of full length trussing with adequate clamps, this lighting bar painted in side, outside with zinc chromate primer finally coated with black quick drying enamel paint required which is suspended from ceiling in front of stage to focus stage. 36ft Length. Approved Brands: Canara/ Stage Works/ Illumitex/ Effectron

1

-

-

... More
Side Ladder: P/f of the side ladders made out of 50x25mm MS tube pipe size: 4x2 ft.. Approved Brands: Canara/ Stage Works/ Illumitex/ Effectron

6

-

-

... More
350w17R super beam moving head light double prisms(rainbow effects), glass gobos. oltage, AC100-240V 50/60Hz Power consumption: 500W Light Source: PHILIPS 350W lamp Ballast: Electronic Ballast Channels: OMX 18/22 Channels Color wheel: One color wheel, 13 colors + open Gobo wheel: One static gobo wheel, 13 gobos+ open Prism: Two rotating prism, One 16-facet prism and one 32-facet prism Frost: Gradually frost, wash angle 5-30 degree Strobe: 0.5-14/c variable strobe effect Lens: Glass optic lens, linear zoom 0-20 degree Movement: Pan 540 degree, 8/16 bit resolution Tilt 270 degree, 8/16 bit resolution Pan/Tilt movement auto repositioning function. Auto reset when mis-positioned. Three motor makes movement quicker, smoother and more mute. IP Grade: IP20 Approved Brands: Canara/ Stage Works/ Illumitex/ Effectron

4

-

-

... More
54X3W As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete as per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete..: Indoor RGBW slim LED Par, Aluminum Die Cast Approved Brands: Canara/ Stage Works/ Illumitex/ Effectron

32

-

-

... More
200w COB Par LED with barndoor 1x200W warm white+white 2in1/warm white/white Voltage: AC110- 220V, 50-60HZ Power: 100W/200W Light source: 100W COB/200W COB Color: warm white, white Dimming: 0- 100% Control mode: voice, master and slave, self-propelled, DMX512 Channels: 4 / SCH Working temperature: -30 "C -40 "C +RGB Approved Brands: Canara/ Stage Works/ Illumitex/ Effectron

32

-

-

... More
200W cob led studio par light with zoom Input Voltage: AC100-240V, 50-60Hz Power Consumption: 250W LED Quantity: 1 PCS 200W cool white or warm white LEDs Color Rendering Index: (CRI) Ra90 Zoom angle:10 ° to 90 ° Control Signal: DMX512, master-slave, sound, auto mode Control Channels Approved Brands: Canara/ Stage Works/ Illumitex/ Effectron

12

-

-

... More
4 eyes cob led blinder light 100W Voltage / frequency: AC100V-240V/50-60Hz. Rated power: 430W. Light source: 4 ultra-high brightness COB 1 DOW two-in-one LED. Lamp life: about 50,000 hours. Color: Warm white or white or 2-in-1. Color temperature: 3200K - 5600K can be adjusted. Control channel: 8 channels. Light angle: 35° . Dimming: 0-100% linear electronic dimming. Strobe: Independent high-speed electronic strobe, 1-13 times per second. Operating mode: voice control, self-propelled, master­slave, DMX512. Color rendering index: Ra85 Waterproof rating: IP20 Approved Brands: Canara/ Stage Works/ Illumitex/ Effectron

8

-

-

... More
200w fresnel light with barndoor Input voltage: AC100-240V, 50/60Hz Power: 220W Light source:100W/150W/200W high indicates COB LED lamp. Color rendering index: Ra95 Light source life: 100000 hours Color temperature: 3200K, 5600K optional. Control panel: LCD liquid crystal display + four buttons Beam angle: 15-60 degrees Manual zoom Dimming: 0-100% linear dimming. Cooling method: copper radiator. Channel mode: 1 CH/2CH. Control mode: DMX512 control/manual control. Protection level: IP20 Working temperature: -25° C- +45° C Shell Material: Aluminum Alloy Accessories : Concealer, power cord, signal cable Approved Brands: Canara/ Stage Works/ Illumitex/ LBT

4

-

-

... More
200W LED profils Input Voltage: AC100-240V, 50/60Hz Power Consumption: 260W LED POWER: 200W LED Quantity; 1 PCS 200W white or warm white LED Color Temperature: 3200K or 5700K color temperature Color Rendering Index: (CRI) Ra90 Beam Angle: 19° (26° /36° also available) Control Signal: DMX512, master-slave.auto mode Control Channel: 1/3CH DMX512 channel Product Dimensions: 550•270•185m Approved Brands: Canara/ Stage Works/ Illumitex/ LBT

2

-

-

... More
Follow spot 7R Input voltage / frequency: AC220V ± 10% / 50-60Hz. Rated power: 250W/280W. Light source: Use a 200W/230W cup. Beam angle: 15° . The combination of new aluminum alloy and die-cast steel plate is beautiful and elegant. Manual focus adjustment. The aperture size is adjustable. Adjust the strobe manually. color: White. Protection level: IP20. Approved Brands: Canara/ Stage Works/ Illumitex/ Effectron

1

-

-

... More
LED54/72/108/120Pcs Non-waterproof Flood Light Rated power: 250W Light source: 54/72/108/120 high brightness and high power 3W LED. Lamp life: about 50,000 hours. Color: RGBW color mixing, bright colors, rich colors and bright, can combine 16,777,216 color changes. Dimming: 0-100% linear dimming. Control channel: 6CH. Beam angle:15, 25 degrees optional. Control mode: DMX512, master-slave control, self­ propelled, voice control. Protection level: IP20. Approved Brands: Canara/ Stage Works/ Illumitex/ LBT

8

-

-

... More
Splitter 8 channel 4/8 independent amplification driver output.The signal amplifying and shaping !unction, extending the signal transmission distance.To enhance the capacity of data bus access equip men! number. To protect the lighting console DMX512 output interface.fault isolation, improve the safety and reliability of digital lighting Approved Brands: Canara/ Stage Works/ Illumitex/ LBT

4

-

-

... More
Mini pearl 1024 lighting controller with flight case 1. Audio signal input 2. MIDI input or output 3. Via RS 232 System interface 4. DMX 512 signal 1024 channel Power supply: 25 V.DC 0.5A Approved Brands: Canara/ Stage Works/ Illumitex/ LBT

1

-

-

... More
3000W DMX Fog Machine Voltage: AC 110 / 230V 50-60Hz ± 10% Power: 3000W Warm-up time: 12 minutes Smoke oil capacity: 10 liters; Spray distance: 20 meters Smoke cover: 40000cu.ff / min Control mode: timing quantitative / DMX512 control Approved Brands: Canara/ Stage Works/ Illumitex/ LBT

2

-

-

... More
DJ Power Fog oil (5L) applicable to any mode smoke/fog machine by any factory new plasma formula no static elec. no fire crystallization harmless to body and equip lasting fragrance

1

-

-

... More
DMX 3-Pin Male XLR – 3-Pin Female XLR DMX Cable: Supply, Installation, Laying, Testing & Commissioning of DMX Data Signal Point Wiring : Using 2-core PVC insulated 22AWG multi-stranded Cu.Cond. high speed data cable designed for EIA485 ; lowcapacitance, twisted pair shielded ; FHDPE insulation - starting from DMX Splitter to each Light Bar - either sides, Side Ladders and Floor Points, as required to be terminated with suitable XLR connectors Approved Brands: NUTRIK, SUNRISE or LOSEN

115

-

-

... More
LIGHTING SAFETY HOOK Features Choose from multiple lengths and safety bond types Galvanised steel cable Black PVC coated Black steel cable Screw-gate carbine hook Shackle Designed and manufactured in the UK! Specifications Cable diameter: 3mm Working Load Limit (WLL): 25kg

110

-

-

... More
Black Steel Hook: G CLAMP Strong metal G clamp fitted with protector strip designed for hanging light effects. Fits on bars up to 50mm diameter.

120

-

-

... More
Supply, Installation, Testing & Commissioning of Wiring for Direct Points Using PVC Insulated Finolex 1.5 sqmm 3Core FRLS Cu.Cond. cable for 2 sockets/box ; 30 No. Core FRLS Cu.Cond. cable for 2 sockets/box ; starting from the supplied MCB Box/Panel, having 10A SP MCBs, to the Lighting bars/tree or stage points ; terminated at junction box with 2 x SHUCKO 16 Amp. Sockets/per point (all points to be marked & numbered)

115

-

-

... More
Supply of Step light 4 ft - warm white Up and Down throw Along with 6 compatable Power supply 20 AMPS, 22 lights can be operated through one powersuppy

110

-

-

... More
Exit Signage for Doors

6

-

-

... More
LED Foot Lamp 2W / 3W Philips

46

-

-

... More
SITC of Push Back Auditorium Chair: As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc PUSH BACK CHAIRS is an optimally designed chai for use in and auditoriums Epoxy powered coated paint for all steel parts. • 25mm x 5mm MS flat made back inner frame with 3 serpentine springs. • PPCP plastic molded one-piece inner seat frame Molded polyurethane foams cushioned seat back. • Upholsters with flame retardant fabric (Option scotch guard for stain resistance) • Zipper attached to seat back fabric for easy resolvability • Epoxy powered coated paint for all steel parts • Integrated skin type PU foam made arm rest with or without cup holder • Maintenance free synchronized push back system, with seamless seat supporting tray • Heavy gauge CRC sheet made side stand covered with fabric 4.5kg • Back side of the back covered with PPCP plastics back cover • Chairs installed to the floor with expended anchor fasteners Approved Brands: CINEMA WORKS / INNOVATIVE / WIPRO

278

-

-

... More
SITC OF UNIQUE DESIGNER SOFA CHAIR is an optimally designed chairs for use in and auditoriums.Prime seat with comfort cushioning and push back mechanism large size with big comfort armrest with upholstery. • Push back type Auditorium chair. • Molded polyurethane foam. The foam will be non-sagging (Density: 50+/-5Kg/M3) • CRC sheet in push back system and side stand of the as shown in photograph. • 12mm ply seat. And MS Pipe 19mm and flat of size 25mm x 6mm in frame of back. • M.S flat of size 25mm x 6mm from arms and of size 40mm x 4mm for arm holder • Push back system Synchronized push back system 16G seat supporting tray (as per model) 2 no’s 14G back clamps 2 no’s 16 G roller holders with 2 no’s 30mm rolls 2 no’s 50X25mm MS tubes of 16G tube 4 no’s 25X6mm MS flat arms • Side stand • Heavy gauge as per design and construction • 6-gauge one piece footrest • Covered with duly laminated upholstery fabric in seat back • Arms rests with cup holder will of PPCP model in shape and design • The distance between center to center of arm of the chair will be 21” to 23” as per requirement • The total heigh of the chairs from floor level will be 37” • Seat and back will be covered with 100% polyester fabric Approved Brands: CINEMA WORKS / INNOVATIVE / WIPRO

18

-

-

... More
SITC of LR High Power Full Range Loudspeaker Two-way Passive/ Biamplified Switchable 1 x 15" Point Source or better RMS Power Handling (LF): 350-400 W or better RMS Power Handling (HF): 70-80 W or better Impedance : 8 Ohms Frequency Range : 60 Hz - 18 kHz Maximum SPL:124 dB or better, Peak SPL: 130 dB or better System Sensitivity: LF-99dB, HF-105dB or better Dispersion (H x V) - 70-80 degree x 40-50 degree Rotatable or better Rigging point for Ceiling hanging Birch plywood Enclosure Complete with flying arrangements as per site requirements Approved Makes : Tannoy / Renkus Heinz / d&b Audio technik

2

-

-

... More
SITC of High Power Dual 12" Subwoofer 2 X 12" LF Driver or better driver configuration RMS Power 750 W or better Impedance : 4 ohms Frequency Response : 35 Hz - 200 Hz Maximum SPL : 135 dB Peak or better System Sensitivity : 100dB free field Birch Plywood Construction Rigging point for ceiling hanging Complete with flying arrangements Approved Makes : Tannoy / Renkus Heinz / d&b Audio technik

2

-

-

... More
SITC of Stage Front Fill Compact Two-way Compact Passive Speaker 1 x 8" two way or better loudspeaker RMS Power Handling - 120 W or better Impedence 8 Ohms Frequency Range:: 65 Hz - 18 kHz Maximum SPL: 118 dB Peak System Sensitivity: 91 dB or better Dispersion (H x V) - 90-100 degree x 90-100 degree Birch Plywood Enclosure Complete with U bracket mounting accessories Approved Makes : Tannoy / Renkus Heinz / d&b Audio technik

3

-

-

... More
SITC of Stage Monitor, 2 way Active speaker 1X 12" or better LF driver configuration Class-D Amplifier Peak Power: 1000W or better Frequency Range: 70 Hz - 18 kHz Maximum SPL: 125 dB peak or better Built-in DSP with EQ, Delay, Limiter, Crossover etc. Dispersion (H x V) -60-70 degree x 40-50 degree or better Birch Plywood Construction Approved Makes : Tannoy / Renkus Heinz / d&b Audio technik

2

-

-

... More
SITC of Green Room ,Control Room Compact Surface Mount Loudspeaker Driver : 5" or better 50 W RMS Output System Sensitivity 87 dB Frequency Range 80 Hz - 20 kHz Maximum SPL 111 dB Peak or better 90°or better Horizontal, 60°or better vertical dispersion Complete with mounting accessories Approved Makes : Tannoy / AtlasIED / Martin Audio

2

-

-

... More
SITC of 1200watt Rack Mount Professional Dual channel Power Amplifier with built-in DSP Class D Nos. of channels 2 Power Output : 600 W @ 4 Ohms Integrated DSP with parametric equalizers, adjustable high- and low-pass filters, delay, crossover, multiple filter types Analog & AES3 Inputs Four channel Input Mixer THD + N 20 Hz- 20 kHz for 1 W 0.1% Signal-to-Noise ratio 102 dB Frequency Response 20 Hz- 20 kHz Channel Crosstalk at 1 kHz 80 dB Software configurable limiter Networked control Front LCD Display Approved Makes : Labgruppen / Powersoft / Procella / d&b Audio technik

1

-

-

... More
SITC of 2400watt Rack Mount Professional Dual channel Power Amplifier with built-in DSP Class D Nos. of channels 2 Power Output : 1200 W @ 4 Ohms Integrated DSP with parametric equalizers, adjustable high- and low-pass filters, delay, crossover, multiple filter types Analog & AES3 Inputs Four channel Input Mixer THD + N 20 Hz- 20 kHz for 1 W 0.1% Signal-to-Noise ratio 102 dB Frequency Response 20 Hz- 20 kHz Channel Crosstalk at 1 kHz 80 dB Software configurable limiter Networked control Front LCD Display Approved Makes : Labgruppen / Powersoft / Procella / d&b Audio technik

2

-

-

... More
SITC of Dual channel 120W amplifier Class D type Nos. of channels 2 Per channel Power output : 2 × 60 W @ 4 ohms, 8 ohms, 70 /100 V THD 20Hz-20kHz at 1 W 0.5% or better Signal-to-noise ratio90 dBA or better Frequency Response 20 Hz - 20 kHz It should be energy star rated Approved Makes : Labgruppen / Powersoft / AtlasIED

1

-

-

... More
SITC of Digital Mixing Console 32 mic inputs, 24 bus, 16 Aux outs Main LCR out and Matrix outputs Built in Stage Box Interface 24 bit ADC and DAC converters Minimum 112 dB dynamic range Minimum 24 motorised 100 mm faders Optional wireless remote control for iPhone* and iPad* etc 32 x 32 channel USB 2.0 audio interface 8 DCA / VCA and minimum 6 mute groups Built in effect processor Complete with Built in external 100-Band RTA for all Channel/Bus EQ 's, Auto-ranging universal switch-mode power supply Digital mixer should be supplied with 32 inputs and 16 output stage Box, etc complete. Approved Makes : Behringer / Yamaha / Allen & Heath

1

-

-

... More
SITC of Digital Signal Processor AEC Mic / Line Input: min 10 No's Line Output: min 6 No's USB Audio Interface 24Bit, 48Khz GPIO Contcats: 6 No's Built in Digital Audio DANTE Network with 64 x 64 Channel Frequency Response: 20Hz to 20KHz Ethernet Port: Yes RS232 connector for interfacing with 3rd party control systems Crosstalk (inter-channel @ 1 kHZ): -75 dB Common mode rejection: Typically, -60 dB at 1 kHz Latency: 1.8ms Maximum output level: -31 dBu to +24 dBu THD+N : 0.005%, Dynamic range: 105 dB Approved Makes : Klark Teknik / Biamp / Symmetrix

1

-

-

... More
SITC of Hypercardioid dynamic handheld Vocal microphone Frequency Response of 90 - 16,000 Hz Open Circuit Sensitivity –55 dB (1.7 mV) re 1V at 1 Pa Impedance-300 ohms or better On/off switch Integral 3-pin gold-plated XLRM-type connector Rugged all-metal construction complete with stand clamp and threaded adaptor and Carry Case Approved Make: Audio Technica / Shure / Sennheiser

6

-

-

... More
SITC of Cardioid condenser Instrument microphone for Guitars, Piano, Violin, Flute Frequency Response of 40Hz - 20,000 Hz Open Circuit Sensitivity –49 dB (3.5 mV) re 1V at 1 Pa Maximum Input Sound Level: 159 dB SPL, 1 kHz at 1% T.H.D. Dynamic Range: 130 dB, 1 kHz at Max SPL Signal-to-Noise Ratio: 65 dB, 1 kHz at 1 Pa Impedance- 200 ohms Integral 3-pin gold-plated XLRM-type connector Rugged all-metal construction complete with stand clamp and threaded adaptor and universal Clip-On Mount, Violin Mount, 5" Goosenck for multipurpose use. 4 meter cable inlcuded attacehd to microphone Approved Make: Audio Technica / Shure / Sennheiser

2

-

-

... More
SITC of Hypercardioid Cardioid Dynamic Instrument microphone for Percussions, Guitar, Harmonium Frequency Response of 80Hz - 17,000 Hz Open Circuit Sensitivity –56 dB (1.5 mV) re 1V at 1 Pa Impedance- 300 ohms Integral 3-pin gold-plated XLRM-type connector Rugged all-metal construction complete with stand clamp and threaded adaptor and soft pouch included Approved Make: Audio Technica / Shure / Sennheiser

2

-

-

... More
SITC of Cardioid Condenser Hanging Microphone Frequency Response of 30Hz - 20,000 Hz Open Circuit Sensitivity –39 dB (11.2 mV) re 1V at 1 Pa Maximum Input Sound Level: 139 dB SPL, 1 kHz at 1% T.H.D Dynamic Range: 115 dB, 1 kHz at Max SPL Signal-to-Noise Ratio: 70 dB, 1 kHz at 1 Pa Impedance- 250 ohms Integral 3-pin gold-plated XLRM-type connector Rugged all-metal construction complete with two-stage foam windscreen; steel hanger; power module; stand adapter Approved Make: Audio Technica / Shure / Sennheiser

4

-

-

... More
SITC of Cardioid Condenser Boundary Microphone Frequency Response of 20Hz - 20,000 Hz Open Circuit Sensitivity -34 dB (19.9 mV) re 1V at 1 Pa Maximum Input Sound Level: 134 dB SPL, 1 kHz at 1% T.H.D. Dynamic Range: 108 dB, 1 kHz at Max SPL Signal-to-Noise Ratio: 68 dB, 1 kHz at 1 Pa, A-weighted Impedance- 50 ohms Integral 3-pin gold-plated XLRM-type connector Rugged all-metal construction complete with 7.5 meter cable and Soft protective pouch Approved Make: Audio Technica / Shure / Sennheiser

4

-

-

... More
SITC of Drum microphone kit Cardioid condenser microphones ideal for drum overhead miking 4 nos. of cardioid dynamic snare/tom microphones 1 Nos of cardioid dynamic kick microphone 2 x cardioid condenser microphones ideal for drum overhead miking complete with mounts and carrying case Approved Make: Audio Technica / Shure / Sennheiser

1

-

-

... More
SITC of Cardioid Condenser Quick-Mount Gooseneck Microphone with RFI shielding Element : Fixed-charge back plate, permanently polarized condenser Gooseneck Length: 18"-20" Frequency Response : 30-20,000 Hz Impedance : 250 ohms Maximum Input Sound Level 138 dB SPL, 1 kHz at 1% T.H.D. Signal to Noise Ratio 70 dB, 1 kHz at 1 Pa Dynamic Range 115 dB, 1 kHz at Max SPL RFI-shielding Complete with Anti-Shock Microphone Stand with on/Off Switch Approved Make: Audio Technica / Shure / Sennheiser

2

-

-

... More
SITC of Digital Wireless headworn and lapel microphone system Cardioid dynamic Lapel/collar (1 no.) and headworn capsule (1 nos.) Frequency Response of 20 Hz to 20 kHz RF output power 10 mW or better Total Harmonic Distortion 0.05% typical or better Dynamic Range 109 dB or better Operating Frequencies 2.4 GHz ISM band (2400 to 2483.5 MHz) or better Operating range 60 mtrs or better Audio Sampling 24 bit / 48 kHz Latency 3.8 mS or better Including Antena Extension system for clear communication between Stage and AV Control room Approved Make: Audio Technica / Shure / Sennheiser

1

-

-

... More
SITC of Digital Wireless Handheld microphone Hypercardioid dynamic transmitter with 2 nos. Handheld Capsule Frequency Response of 20 Hz to 20 kHz RF output power 10 mW or better Total Harmonic Distortion 0.05% typical or better Dynamic Range 109 dB or better Operating Frequencies 2.4 GHz ISM band (2400 to 2483.5 MHz) or better Operating range 60 mtrs or better Audio Sampling 24 bit / 48 kHz Latency 3.8 mS or better Including Antena Extension system for clear communication between Stage and AV Control room Approved Make: Audio Technica / Shure / Sennheiser

1

-

-

... More
SITC of Active Stereo DI Box for electronic instruments 48 V phantom Power Extended Dynamic Range High quality Neutrik* XLR and high impedance 1/4” TRS connectors Frequency response 10 Hz to 90 kHz Earth lift switches Impedance 75 Ω Approved Make: Klark Teknik / Cardinal / Radial

2

-

-

... More
SITC of Floor mount boxes with 4 x XLR Microphone input with Neutrik Connector etc as required Make: Custom with Neutrik Connector

6

-

-

... More
SITC of Floor mount boxes with 2 x XLR Microphone output with Neutrik Connector etc as required Make: Custom with Neutrik Connector

4

-

-

... More
SITC of Active Decora-style wallplate (shall be mounted inside floor box on stage) System Type: Wall plate HDBaseT transmitter for HDMI and USB-C Input Port: 1 x HDMI, 1 x USB-C Output Port: 1 x HDBaseT Data Port: 1 x USB Host, 1 x USB HUB Signal & Control Extension: Tranmitter for AV, Power, Control & Data upto 100mtr using CATx cable Resolution Support: 4K/UHD @ 60 Hz with 4:2:0 Remotely powered over HDBaseT Auto Switching: Select Active input via Hot Plug & Video Detect Technology Auto Display Control: Automatic Display On / Off control based on switcher. Control signals to display are transmitted via IP, RS-232 or CEC. Chroma Subsampling: 4:4:4, 4:2:2, 4:2:0 Color Depth: 8-bit, 10-bit, 12-bit Bandwidth 10 Gbps HDCP & EDID Management Control : TCP/IP and RS-232 Cable Link Monitoring: Integrated HDBaseT link status monitoring Enclosure: One / Two Gang for Wallplate Opening Approved Makes : Atlona / Extron / Lightware

1

-

-

... More
SITC of HDBaseT receiver for HDMI and USB System Type: HDBaseT Receiver for HDMI with USB Input Port: 1 x HDBT Output Port: 1 x HDMI Data Port: 2 x USB Hub or more Signal & Control Extension: Receiver for HDMI, Ethernet, power, control, and USB upto 100mtr using CATxx cable Resolution Support: 4K/UHD @ 60 Hz with 4:2:0 Remote powering over HDBaseT or local powering Chroma Subsampling: 4:4:4 Color Depth: 8-bit, 10-bit, 12-bit HDCP 2.2 & CEC Pass-through Cable Link Monitoring: Integrated HDBaseT link status monitoring Approved Makes : Atlona / Extron / Lightware

1

-

-

... More
SITC of Wireless Presentation system Allows simultaneous content sharing from up to four presenters Allows a user to manage on-screen presenters as well as queued presenters Integrated WI-FI Access Point – can be segregated from the facility LAN for security reasons Support URL-Based digital signage platforms Supports youtube live streaming Dynamic Layout Mode - automatically adapts to incoming or disconnected source content Wireless screen casting through native AirPlay, Google Cast, or Miracast protocols Supports wireless video upto 1080p/30 4:2:0 Local storage for playback of images and video Approved Makes : Atlona / Extron / Barco

1

-

-

... More
4K HDR Four-Input HDMI Switcher System Type: 4K HDR Four-Input HDMI Switcher Input Port: 4 x HDMI Output Port: 1 x HDMI Resolution Support : 4K/UHD @ 60 Hz with 4:4:4 HDR10 Support Auto Switching: Select Active input via Hot Plug & Video Detect Technology Manual Control: Front Panel Input Selection Signal Bandwidth: 10.2 Gbps HDCP 2.2 compliant Complete with HDMi Audio De-Embedder Approved Makes : Atlona / Extron / Lightware

1

-

-

... More
SITC of 4K/UHD HDMI Extender Kit with Control and Remote Power: Supports resolutions up to 4K/UHD 60 Hz 4:2:0 System Type: 4K/UHD HDMI Extender Kit with Control and Remote Power Transmitter : Input Port: 1 x HDMI & Output Port : 1 x HDBT Receiver : Input Port: 1 x HDBaseT & Output Port : 1 x HDMI Signal & Control Extension: Tranmitter for AV, Power & Control upto 70mtr using CAT6a/7 cable Resolution Support: 4K/UHD @ 60 Hz with 4:2:0 Remote power, transmitter powers receiver over HDBaseT LED Indicator: To provide power and link status information HDBaseT link test verifies cable, termination, and link quality Chroma Subsampling: 4:4:4, 4:2:2, 4:2:0 Color Depth: 8-bit, 10-bit, 12-bit Approved Makes : Atlona / Extron / Lightware

1

-

-

... More
SITC of 1-chip DLP LASER Phosphor Projection system having, 10000 Lumens 20000 hours lamp life Brigtness 10000 Lumens 20000 hours lamp life 1920 x 1200 WUXGA Native Resolution Automated alignment, warping and belnding 300,000:1 Contrast Ratio or better Inputs: HDBaseT,HDMI2.0, DVI-D, Active 3D, With Zoom lens with throw distance of 22mtr to 30mtr Approved Makes : Christie / NEC / Barco

1

-

-

... More
SITC of 3.5mtr x 5.6 mtr fixed projection screen 3.5m x 5.6m fixed projection screen with 1.4 gain fabric on light weight alunminum frame as per site requirements. Approved Makes : Harkness Hall / / Da-Lite / Draper

1

-

-

... More
SITC of AV Control processor IP based control System Support RS232 devices to complete the system requirements Support IR devices to complete the system requirements IP port for control of third party devices Support Necessary Relay devices to complete the system requirements DHCP server for AV LAN. complete with license to support Apple devices Approved Makes : Atlona / Extron / AMX

1

-

-

... More
SITC of wireless 10" I-Pad 10" Wireless iPAD for GUI Control. Complete with charging base Approved Makes : Apple

1

-

-

... More
SITC of 16port Network Switch 16port PoE enabled network switch Approved Makes : Linksys / HP / Netgear

1

-

-

... More
SITC of Wireless Access Point PoE enabled Standards 802.11n wireless LAN 802.11g wireless LAN Approved Makes : Linksys / HP / Netgear

2

-

-

... More
SITC of Rack Structure 30U With front glass door power distribution box Internal fans and lights, wheels Approved Make: Valrack/Rittal/AtlasIED

1

-

-

... More
SITC of 4 Sqmm x 2 core(12AWG) ATC copper Conductor, Insulated Cores,PVC Sheathed Speaker Cables complete etc as required.(as per actual) Approved Make: Krystal / Canare / Belden

150

-

-

... More
SITC of 2.5 Sqmm x 2 core(12AWG) ATC copper Conductor, Insulated Cores,PVC Sheathed Speaker Cables complete etc as required.(as per actual) Approved Make: Krystal / Canare / Belden

300

-

-

... More
SITC of 22 AWG 2 core ATC Copper Conductor,PVC Insulated, 90% ATC Copper Braid Shielded, PVC Sheathed Microphone Cable complete etc as required. (as per actual)Supplying and fixinf of Connectors, terminal strips in junction boxes & Provision to fly loudspeakers etc as required Approved Make: Krystal / Canare / Belden

300

-

-

... More
SITC of CAT-6STP Cable,4pair,0.58mmBare copper,ATC Copper Braid Shielded,PVC Sheathed(as per actual) Approved Make: Panduit / AMP / Sommer

200

-

-

... More
SITC of Molded HDMI Cables of various length 3' / 6'/10' Various length of HMI cable 3',6',10' as per design requirement. 18Gbps Bandwidth Approved Make: Atlona / Extron / Kramer

1

-

-

... More
SITC of Various Audio Connectors Approved Make: Neutrik / Amphenol / Switchkraft

1

-

-

... More
SITC of 6" 2-way In-Ceiling Loudspeaker Driver Size : 1 x 6.5” LF Driver , 0.79" or better HF driver RMS Power : 50 W Nominal impedance: 8 Ohm Transformer Taps : 100V / 70V upto 30W Frequency Range : 75 Hz-20 kHz Maximum SPL : Peak - 113dB Dispersion: 110 Degree Conical Sensitivity: 90dB Certification: UL1480, UL2043, EN54-24:2008 certified Aluminum, powder coated grill Approved Makes : Tannoy / Martin Audio / AtlasIED / Bose

6

-

-

... More
SITC of Dual channel 120W amplifier Class D type Nos. of channels 2 Per channel Power output : 2 × 60 W @ 4 ohms, 8 ohms, 70 /100 V THD 20Hz-20kHz at 1 W 0.5% or better Signal-to-noise ratio90 dBA or better Frequency Response 20 Hz - 20 kHz It should be energy star rated Approved Makes : Labgruppen / Powersoft / AtlasIED

1

-

-

... More
SITC of 6 Channel Digital Processor Mixer Inputs : 4 balanced mic, 2 balanced Mic/Line,1 stereo unbalanced input Inputs equipped with Low-cut filter, phase inversion and 4-band EQ Onboard AEC processing 1 stereo and 2 mono outputs Each output channel equipped with adjustable output level, 12-band fully parametric EQ with notch filtering, compressor, limiter, and 8-band feedback suppressor. 2-channel USB audio interface 8 x 3 audio routing matrix Maximum Gain : 64 dB Dynamic Range : 110 dB or better Signal-to-noise ratio:90 dB or better Microphone Phantom Power : +48V DC Front panel Monitoring, Controls and LED indicators Web Remote functionality IP control for third-party CCS administration Digital Link port to further cascasing of processor's Accessories Included : Rack-mount adapters Approved Makes : Klark Teknik / Biamp / Symmetrix

1

-

-

... More
SITC of Cardioid Condenser Quick-Mount Gooseneck Microphone with RFI shielding Element : Fixed-charge back plate, permanently polarized condenser Gooseneck Length: 18"-20" Frequency Response : 30-20,000 Hz Impedance : 250 ohms Maximum Input Sound Level 138 dB SPL, 1 kHz at 1% T.H.D. Signal to Noise Ratio 70 dB, 1 kHz at 1 Pa Dynamic Range 115 dB, 1 kHz at Max SPL RFI-shielding Complete with Anti-Shock Microphone Stand with on/Off Switch Approved Make: Audio Technica / Shure / Sennheiser

1

-

-

... More
SITC of UHF Wireless Cardioid Cardioid condenser lavalier microphone with 55" cable terminated with locking connector Cardioid Condenser Receiving System : Antenna switching diversity Modulation mode : FM Frequency Response : 60 Hz to 16000 Hz RF Sensitivity: 10 dBuV at 60 dB S/N ratio (50 ohms termination) Total Harmonic Distortion: 1.0 % or less Dynamic Range 103 dB or higher Operating range: 60 m RF Power Output High: 10 mW or better No. of Channel : Total 8no of frequencies or more Balanced and unbalanced outputs Lapel with 1.4 m cable Terminated with locking 4-pin connector for body-pack wireless transmitters Accessories Included: detachable Antennas, Rack mount kit Approved Make: Audio Technica / Shure / Sennheiser

1

-

-

... More
SITC of UHF Wireless Handheld microphone system Cardioid Condenser Receiving System : Antenna switching diversity Modulation mode : FM Frequency Response : 60 Hz to 16000 Hz RF Sensitivity: 10 dBuV at 60 dB S/N ratio (50 ohms termination) Total Harmonic Distortion: 1.0 % or less (at 1 kHz, ±17.5 kHz deviation) Dynamic Range 108 dB or higher Operating range: 60 m RF Power Output High: 10 mW or better No. of Channel : 2x 4-frequencies Antenna Input : BNC type, 50Ω - BIAS voltage 12V DC 100mA each Balanced and unbalanced outputs Approved Make: Audio Technica / Shure / Sennheiser

2

-

-

... More
SITC of Transmitter for HDMI and VGA Signal HDBaseT with compatible receiver System Type: 2 x 1 Switcher with HDMI & VGA Input Input Port: 1 x HDMI, 1 x VGA + Audio Output Port: 1 x HDBaseT Signal & Control Extension: Tranmitter for AV,Power & Control upto 70mtr Resolution Support : 1900x1200 upto 70mtr using CAT6a/7 cable 4K/UHD @ 60 Hz with 4:2:0 upto 40mtr using CAT6a/7 cable PoE (Power Over Ethernet): Remotely Powered via PoE Auto Switching: Select Active input via Hot Plug Detect Technology Auto Display Control: Automatic Display On / Off control based on switcher mode via compatible receiver.Control signals to display are transmitted via RS-232. Manual Control: Front Panel Input Selection and On / Off Controls LED Indicator: To provide power and input selection status information Chroma Subsampling: 4:4:4, 4:2:2, 4:2:0 Color Depth: 8-bit, 10-bit, 12-bit Audio Support: PCM 2CH for Analog In & HDMI In / HDBaseT Out Sample Rate: upto 192kHz Signal Bandwidth: 10.2 Gbps HDCP 1.4 Compliant Complete with compatible HDMI Receiver with HDMI audio de-embeddeing Enclosure: US Two Gang for Wallplate Opening Approved Makes : Atlona / Extron / Lightware

1

-

-

... More
SITC of 1-chip DLP LASER Phosphor Multimedia Projection system having, 7000 Lumens 20000 hours lamp life Brigtness 7000 Lumens 20000 hours lamp life 1920 x 1200 WUXGA Native Resolution Inbuilt blending and warping with automatic caliberation software 3D ready 3000,000:1 Contrast Ratio or better Inputs: HDBaseT,HDMI2.0, DVI-D, Active 3D, Motorised zoom and focus Complete with standard zoom lens Approved Makes : Christie / NEC / Barco

1

-

-

... More
SITC of 2mtr x 3.3 mtr motorized projection screen 2m x 3.2m motorized projection screen with manual wall control switch Approved Makes : Elite / Prima / Grandview / Liberty

1

-

-

... More
SITC of Rack Structure 12U With front glass door power distribution box Internal fans and lights, wheels Approved Make: Valrack/Rittal/AtlasIED

1

-

-

... More
SITC of 1.5 Sqmm x 2 core(14AWG) ATC copper Conductor, Insulated Cores,PVC Sheathed Speaker Cables complete etc as required.(as per actual) Approved Make: Krystal / Canare / Belden

80

-

-

... More
SITC of 22 AWG 2 core ATC Copper Conductor,PVC Insulated, 90% ATC Copper Braid Shielded, PVC Sheathed Microphone Cable complete etc as required. (as per actual)Supplying and fixinf of Connectors, terminal strips in junction boxes & Provision to fly loudspeakers etc as required Approved Make: Krystal / Canare / Belden

50

-

-

... More
SITC of CAT-6STP Cable,4pair,0.58mmBare copper,ATC Copper Braid Shielded,PVC Sheathed (as per actual) Approved Make: Panduit / AMP / Sommer

50

-

-

... More
SITC of Molded HDMI Cables of various length 3' / 6'/10' Various length of HMI cable 3',6',10' as per design requirement. 18Gbps Bandwidth Approved Make: Atlona / Extron / Kramer

1

-

-

... More
SITC of Various Audio Connectors Approved Make: Neutrik / Amphenol / Switchkraft

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.