Department Of Housing And Urban Affairs Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 1,96,000Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_DHUA_26006_1Bid Award Id
ViewTender No
CE/HandUA/Tech/17/PT-II/21-22/ 63 Dtd. 17/06/2022Tender Authority
Department Of Housing And Urban Affairs ViewPurchaser Address
-Website
http://assamtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. cum 2928.10
12.35
-
-
Demolishing R.B. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge. cum 2619.45
8.55
-
-
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge.
2.6.1 All kinds of soil cum 205.45
164.82
-
-
Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. sqm 733.3
452.1
-
-
CEMENT CONCRETE (CAST IN SITU)
4.1 ) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5) 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size
derived from natural sources) cum 6833.4
33.13
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :A) In Sub-Structure upto plinth level 5.1.3 ) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de
rived from natural sources)
61.79
-
-
B. In Super Structure ) 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size
derived from natural sources)
29.69
-
-
Centering and shuttering including strutting, propping etc. and removal of form work for :
Foundations, footings, bases for columns
274.48
-
-
4.3) Centering and shuttering including strutting, propping etc. and removal of form work for :
4.3.3 Columns, piers, abutments, pillars, posts and struts sqm . In Super structure
431.45
-
-
STEEL REINFORCEMENT
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 89.65
9390.05
-
-
6.2 ) Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: 6.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand) 5746.8
28.52
-
-
2.25 ) Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 253.95.
118.67
-
-
DAMP-PROOF COURSE
4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) . 370.85
135.46
-
-
6.4) Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in
all shapes and sizes in :
6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand) cum 8512.1
80.37
-
-
CEMENT CONCRETE (CAST IN SITU)
4.1 ) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5) 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size
derived from natural sources) cum 6833.4
5.18
-
-
21.10 Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant
(Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete. sqm 4013.35
6.84
-
-
9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
9.1.1 Second class teak wood
0.53
-
-
9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:-
Butt hinges and necessary screws shall be paid separately)
9.5.1 Second class teak wood
9.5.1.2 30 mm thick shutters
24.29
-
-
CEMENT PLASTER (IN COARSE SAND) 13.5 15 mm cement plaster on rough side of single or half brick wall of mix: 13.5.1) 1:4 (1 cement: 4 coarse sand)
466.41
-
-
CEMENT PLASTER (IN COARSE SAND)
13.4) 12 mm cement plaster of mix :
13.4.1 1:4 (1 cement: 4 coarse sand)
b) In cement mortar 1:4
522.52
-
-
11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,
laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
11.41.2 Size of Tile 600x600 mm
88.2
-
-
11.46 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1
cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.
11.46.2 Size of Tile 600x600 mm
42.3
-
-
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre,shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing
compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum plain board
conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
128.82
-
-
13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
326.44
-
-
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
New work (two or more coats) over and including water thinnable priming coat with cement primer
396.46
-
-
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10
1079.5
-
-
Aplying priming coat:
With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood
96.36
-
-
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and
manufacture
254.76
-
-
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and
bolted with special shaped washers etc. complete.
10.16.1 Hot finished welded type tubes kg
7008.97
-
-
SHEET ROOFING
12.1 ) Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.3 ) 0.63 mm thick with zinc coating not less than 275 gm/ m²
572.42
-
-
12.51 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
12.51.1 Ridges plain (500 - 600mm)
48.04
-
-
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
19.32.1 With common burnt clay F.P.S. (non modular) bricks of
class designation 7.5 each
2
-
-
Internal Water Supply
-
-
-
C.P.V.C. PIPES
18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall
15 mm nominal dia Pipes metre
44.7
-
-
20 mm nominal dia Pipes metre
36
-
-
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
18.52.1 15 mm nominal bore each
(v) 50mm dia
4
-
-
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
(a) 15 mm nominal dia each
4
-
-
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore each
8
-
-
External Water Supply
-
-
-
C.P.V.C. PIPES
18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall
20 mm nominal dia Pipes
26.81
-
-
Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested :
Beyond 12 m and up to 18 m depth
20
-
-
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
G.I. pipe
iv) 100mm diameter
25
-
-
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
5000
-
-
Sanitary Works
-
-
-
17.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
17.2.1 W.C. pan with ISI marked white solid plastic seat and lid each
8
-
-
17.5 Providing and fixing white vitreous china flat back half stall urinal of
size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass,
including painting of fittings and cutting and making good the walls and floors wherever required :
17.5.1 Single half stall urinal with 5 litre P.V.C. automatic
flushing cistern each
6
-
-
17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls
wherever require:
17.7.1 White Vitreous China Wash basin size 630x450 mm
with a pair of 15 mm C.P. brass pillar taps each 3392.85
9
-
-
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
Rectangular shape 1500x450 mm
8
-
-
Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl
plugs etc., complete
8
-
-
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
14
-
-
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms
4
-
-
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm,
including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 225 mm
2
-
-
Providing and fixing toilet paper holder : C.P. brass
14
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings
with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
External work
100 mm nominal dia Pipes
30.84
-
-
65 mm nominal dia Pipes
20
-
-
50 mm nominal dia Pipes
29.9
-
-
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
2
-
-
Providing and fixing soil, waste and vent pipes :
100 mm dia
Sand cast iron S&S pipe as per IS: 1729
4
-
-
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
13
-
-
Electrical works
-
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLS PVC insulated copper conductor single core cable in surface / recessed steel
conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and
earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single
core cable etc as required.
Group A
8
-
-
Group B
8
-
-
Group C
11
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
10
-
-
Group B
20
-
-
Group C
36
-
-
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC Conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop
1
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC Conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
262
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
340
-
-
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
97
-
-
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
40
-
-
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
60
-
-
4x10 sq. mm + 2 X 6 sq. mm earth wire
60
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
1
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
7
-
-
Supplying and fixing PVC batten/ angle holder including connection etc. as required.
18
-
-
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
30
-
-
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 A,36KA,FPMCCB
2
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 way , Double door
1
-
-
8 way , Double door
1
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
2
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
38
-
-
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A
2
-
-
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A
2
-
-
Supplying, installing, testing and commissioning of following capacity End Feed Unit made of 1.6mm thick sheet steel enclosure duly painted with powder coating to existing rising mains complete with TPN disconnector FSU and HRC fuses,mounting stands, cable end box, brass compression gland, connections, earthing etc. as required. 200A TPN
1
-
-
Supplying, installation, testing and commissioning of following capacity overhead distribution bus trunking with aluminium bus bars having current density of 130 A/ sq cm at nominal current rating in 1.6mm thick IP 42 sheet steel enclosure in convenient sections with provision of tapping points for use on, 3 phase, 4 wire, 415 volts, 50 Hz, A.C. supply including jointing of sections, bends, earthing with 2 runs of galvanised iron strips, all installation accessories etc. as required. 200A
1
-
-
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 62.5 mm depth X 2.0 mm thickness
110
-
-
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required.
2
-
-
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1
-
-
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
4
-
-
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
7
-
-
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
30
-
-
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
20
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
510
-
-
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 amps switch
2
-
-
3 pin 5/6 A socket outlet
2
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch, 5/6 A switch
2
-
-
3 pin 5/6 A socket outlet
2
-
-
Non Schedule Item (Rate analysis Enclosed) Supplying and fixing of Philips LED strip batten light fittings complete with Shade, back plate including connection cable, as approved by the Deptt.s etc. as required. a. Philips 20 Watt/2000 lumen 2700 K LED Tube light
24
-
-
Supplying and fixing of Philips make LED ceiling light fittings complete with Shade, back plate including connection cable, as approved by the Deptt.s etc. as required. a. Philips Cool Day Light Aluminium Circular LED surface ceiling Light 15Watt
20
-
-
Supplying, installation, testing and commissioning of the following flood light of LED luminaries complete with all accessories as required complete with necessary support with 2.5 sq.mm. P.V.C. insulated S.C. copper conductor as required and as directed by the department. a. Philips make 90Watt LED Luminaries for Flood Light.
2
-
-
Supplying including fitting and fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt. as required complete and as directed by the Department [ without regulator]. a. Orient Electric 1200mm sweep Ceiling Fan
18
-
-
Supplying including fitting and fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt. as required complete and as directed by the Department a. Orient electric Capacitor Type propeller type ac ventilating fan-exhaust
6
-
-
Supplying including fitting & fixing of LED Bulb 9Watt in the existing Batten Holder as directed by the Dept. as required.
18
-
-
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Grade Solid Aluminium conductor stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour, extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable including connection etc. as specified and directed by the deptt. a. 6.00 Sq.mm 2 Core Aluminium armoured U.G. cable.
260
-
-
b. 10.00 Sq.mm 2 Core Aluminium armoured U.G. cable.
50
-
-
c. 16.00 Sq.mm 2 Core Aluminium armoured U.G. cable.
40
-
-
d. 25.00 Sq.mm 4 Core Aluminium armoured U.G. cable
160
-
-
Supplying including installation of the Octagonal poles with single arm shall be designed to withstand the maximum wind speed of 169 km/hr. The top loading i.e. area and weight of fixtures are to be considered to calculate maximum deflection of the poles and the same shall meet the requirement of BS:5649 Part VI 1982. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. (Nezone make) as directed and specified by the Deptt.
8
-
-
Supplying with fitting & fixing of the following LED Street light luminaries complete with lamp in the existing pole including making necessary connection as approved by the Deptt. with 2 ×1.50 sq.mm F.R. multistrand and P.V.C. insulated single core copper cable as specified and directed by the department. a.BAJAJ Make LED Streetlight 90Watt
8
-
-
Supplying including testing & Commissioning of Monoblock Pump set complete as directed and specified by the Deptt. 1HP Single Phase Crompton make
2
-
-
Add APDCL Load Security/Meter Security etc. for service connection
8
-
-
Supplying including installation, testing and commissioning of Air/Water Cooled Diesel Generator set coupled to suitable alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f. mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) Standard Control Panel.5) Suitable batteries with lead.,6) First fill of lube oil.,7) Acoustic Enclosure complete with all accessories as specified and directed by the department 15KVA, 1Phase, Approximate Size 1770x1050x1550, Approximate Weight 900 Kg., Air Cool. Make- KOEL
1
-
-
PUBLIC ADDRESS SYSTEM : Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required.
1
-
-
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
2
-
-
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
2
-
-
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Single pair, 2-core, 1.5 sqmm
70
-
-
Supplying , installation and commissioning of the following Chair of Godrej complete with all accessories as required complete with necessary support as directed by the department.
60
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements