Bridge And Roof Company India Limited Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Bridge And Roof Company India Limited Tender

Works
Eprocure
Opening Date20 Sep 2024
Closing Date18 Nov 2024
Tender Amount₹ 4,77,68,552 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Unit rate for +/- 0.5 meters change in height of lift (during detail engg stage) of Jib Crane (i.e beyond the specified limit of 4 ±0.5 meter, for details ref SOW doc no. B302-000-80-42-SOW-9515) for addition/ deletion purpose.

0.5

440

880

... More
EOT CRANE FOR HAZARDOUS AREA APPLICATION Storage & handling at work site, assembly at site, erection, complete installation with structural members, testing, touch-up painting, pre-commissioning, commissioning, performance guarantee test run including arrangement of test loads, completing the work in all respects and handling over to NRL, as per drawing, specifications, scope of work and instructions of engineer in charge and other attachment included in Tender for the following EOT Crane. Note:- i) Shifting of all Vendor's supplied materials as per the packing list provided by the Vendor from BANDR/EIL/NRL warehouse to erection site to carry out the Erection, Testing & Commissioning work of EOT Cranes with the presence and supervision.of the Vendor's representative at site.

-

-

-

... More
1 No. Double Girder E.O.T Crane for Main Line Pump of 10MT (Safe Working Load) of Span ~ 18.1m, Long Travel ~ 53 m, Height of lift ~ 8 m, "M5" duty along with rails, fixtures and other accessories. (Refer Scope of Work , Job Specification & Electrical specifications (Safe/Hazardous) enclosed elsewhere with this tender document)

1

386159

386159

... More
UNIT RATES FOR E.O.T CRANE FOR ADDITION/DELETION PURPOSE

-

-

-

... More
Unit Rate (ADDITION / DELETION) for ±0.5m in HEIGHT OF LIFT (over & above 1 m from specified data) for E.O.T Crane

1

30015

30015

... More
Unit Rate (ADDITION / DELETION) for ±0.5m in SPAN (over & above 1 m from specified data) for E.O.T Crane including rail fixtures.

1

30015

30015

... More
Unit Rate (ADDITION / DELETION) for ±0.5m in LONG TRAVEL (over & above 1 m from specified data) for E.O.T Crane including rail fixtures.

1

30015

30015

... More
CHAIN PULLEY BLOCK Transportation from storage site to work site, storage & handling at work site including installation and carrying out trial and starts up runs and testing ( including arrangement of test loads) and rectifying defects of any , completing the work in all respects and handing over to NRL as per this scope of work, Job specification, drawing, BANR/EIL Standrad specifications, data sheet and instructions of Engineer in charge and other attachments included in tender. Note: (i) Shifting of all Vendor's supplied materials as per the packing list provided by the Vendor from BANDR/EIL/NRL warehouse to erection site to carry out the Erection, Testing & Commissioning work of Chain Pulley Block with the presence and supervision.of the Vendor's representative at site.

-

-

-

... More
Spark resistant Chain Pulley Block with Geared Trolley : 1 Nos. x 1MT (Safe Working Load) (height of lift : 6 m) for IPPS-3 for maintenance of Basket Filters

1

6790

6790

... More
ERECTION, INSTALLATION & COMMISSIONING OF EQUIPMENT: FILTERS Handling and transportation of Equipment from Owner's storage point to work site/contractor's stores. Assembly of subassemblies, placing the equipment on foundations, levelling, aligning, chipping and dressing of foundations, grouting (including supply and applications of grout material), cleaning and flushing with water, draining and drying with compressed air. Application of touch-up paint (if required) after erection and assembly at site, providing manpower for carrying out pre-commissioning, commissioning and testing under the supervision guidance of Manufacturer's/Owner's personnel and rectifying defects, if any and completing the work in all respects as per drawing(s), specifications, scope of work and instructions of engineer in charge and other attachment included in the Tender for each of the following equipment and accessories listed below Note:- Grouting materials shall be supplied by contractor

-

-

-

... More
Three (3) numbers of Basket Filters (Tag No: 4P38‐GN‐0441A/B/C) (with weight of each filter upto ~ 12 MT ) in IPPS-3. Refer detailed Scope of Work also included as part of Tender Document.

3

543252

181084

... More
HOT CRANE Assembly at site, erection, installation, testing, touch-up painting, pre-commissioning, commissioning, performance guarantee test run including arrangement of test loads, completing the work in all respects and handling over to NRL, as per drawing, specifications, scope of work and instructions of engineer in charge and other attachment included in this Tender. for following HOT Crane. handling, loading, unloading and storage, complete site works including transportation from storage site to work site, storage & handling at work site. NOTE 1: i) Shifting of all Vendor's supplied materials as per the packing list provided by the Vendor from BANDR/EIL/NRL warehouse to erection site to carry out the Erection, Testing & Commissioning work of HOT Crane with the presence and supervision.of the Vendor's representative at site.

-

-

-

... More
1 No. Single Girder H.O.T Crane for Fire Water Pump House of 5MT (Safe Working Load) of Span ~ 6.5 m, Long Travel ~ 25 m, Height of lift ~ 5 m, along with rails, fixtures and other accessories for IPPS-3. (Refer Scope of Work, Job Specification, etc. enclosed elsewhere with this tender document)

1

52619

52619

... More
UNIT RATES FOR H.O.T CRANE FOR ADDITION/DELETION PURPOSE

-

-

-

... More
Unit Rate (ADDITION / DELETION) for ±0.5m in HEIGHT OF LIFT (over & above 1 m from specified data) for H.O.T Crane

1

9005

9005

... More
Unit Rate (ADDITION / DELETION) for ±0.5m in SPAN (over & above 1 m from specified data) for H.O.T Crane including rail fixtures.

1

9005

9005

... More
Unit Rate (ADDITION / DELETION) for ±0.5m in LONG TRAVEL (over & above 1 m from specified data) for H.O.T Crane including rail fixtures.

1

9005

9005

... More
EQUIPMENT - ROTATING

-

-

-

... More
INSTALLATION TESTING AND COMMISSIONING OF DG SET (TAG NO.38-DG-101)

-

-

-

... More
Installation, testing, pre-commissioning and commissioning (as applicable) and Documentation as per the enclosed BANR/EIL Standrad specifications, scope of work, datasheets etc. and other codes and standards attached or referred. For complete scope details refer Data sheet and scope of work document no B302-000-80-42-SOW-9515. Note : (i) Shifting of all Vendor's supplied materials as per the packing list provided by the Vendor from BANDR/EIL/NRL warehouse to erection site to carry out the Erection, Testing & Commissioning work shall be done under the presence and supervision.of the Vendor's representative at site. ii) Grouting materials shall be supplied by contractor.

1

35190

35190

... More
Installation and assembly of Rotating Equipment Packages by Contractor. Handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owner's storage points to work site / contractor's stores, assembly of sub-assemblies (as applicable) placing the equipment on foundations, (including some amount of cutting, welding & field joints wherever required), levelling, aligning, including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipment for NDT, testing, carrying out trial and start-up runs and testing under supervision of Vendor's representative/manufacture's / customer personnel, rectifying defects (if any), insulation (as applicable), precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of BANDR Engineer-in-Charge for each equipment including drivers and accessories, as listed below. NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items).

-

-

-

... More
All type of Pumps Packages with drivers, auxiliaries and accessories.

-

-

-

... More
Sump Pumps (Tag no. 4P38-PA-0402/403)- Quantity - (2) No. Complete erection (on respective installation location), testing and commissioning etc. as per scope of work document no. B302-000-80-42-SOW-9515, datasheets etc. and other codes and standards as attached or referred. Note (i) Shifting of all Vendor's supplied materials as per the packing list provided by the Vendor from BANDR/EIL/NRL warehouse to erection site to carry out the Erection, Testing & Commissioning work of the Sump Pumps with the presence and supervision.of the Vendor's representative at site.

2

896228

448114

... More
Dosing Skid Tag no. 4P38-ZM-8801, Comprising of CI Dosing Pump 4P38-PA-8801A/B) - Quantity- (1) no. Complete erection (on respective installation location), testing and commissioning etc. as per scope of work document no B302-000-80-42-SOW-9515, datasheets etc. and other codes and standards as attached. Note : (i) Shifting of all Vendor's supplied materials as per the packing list provided by the Vendor from BANDR/EIL/NRL warehouse to erection site to carry out the Erection, Testing & Commissioning work of the Dosing Skid with the presence and supervision.of the Vendor's representative at site.

1

38192

38192

... More
FIRE WATER MAIN PUMP (Tag no. 4U56-PA-4301A/B/C)- (Qty- One (3) Nos. Erection, testing, pre-commissioning and commissioning (as applicable) & documentation as per BANR/EIL Standrad specification, datasheets etc. and other codes and standards as attached or referred. For complete scope details refer PDS and scope of work document no B302-000-80-42-SOW-9515. Note : (i) Shifting of all Vendor's supplied materials as per the packing list provided by the Vendor from BANDR/EIL/NRL warehouse to erection site to carry out the Erection, Testing & Commissioning work of the Fire Water Main Pumps with the presence and supervision.of the Vendor's representative at site.

3

254610

84870

... More
JOCKEY PUMP FOR FIRE WATER SERVICE (Tag Nos. 4U56-PA-4302A/B) (Qty-Two (2) Nos) Erection, testing pre-commissioning and commissioning (as applicable) & documentation as per EIL standard specification, datasheets etc. and other codes and standards as attached or referred. For complete scope details refer PDS and scope of work document no B302-000-80-42-SOW-9515. Note : (i) Shifting of all Vendor's supplied materials as per the packing list provided by the Vendor from BANDR/EIL/NRL warehouse to erection site to carry out the Erection, Testing & Commissioning work of the Jockey Pumps for Fire Water with the presence and supervision.of the Vendor's representative at site.

2

84870

42435

... More
ALIGNMENT AND COMMISSIONING OF ROTATING EQUIPMENTS

-

-

-

... More
ALIGNMENT AND COMMISSIONING OF ROTATING EQUIPMENTS (Transportation and Erection shall be done by B AND R) Alignment and Commissioning of Rotating Equipment & miscellaneous items of equipment package from Owner's storage points to work site / contractor's stores, assembly of sub-assemblies, field assembly (as applicable), (including some amount of cutting, welding & field joints wherever required), levelling, aligning, including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipment for NDT, testing, carrying out trial and start-up runs and testing under supervision of manufacture's / customer personnel, rectifying defects (if any), insulation (as applicable), pre-commissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment ( Pump Tag No.4P38-PA-0401A/B/C/D) including drivers and accessories, components complete in all respect. NOTE: Scope also includes insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items).

130

860860

6622

... More
EQUIPMENT - STATIC

-

-

-

... More
STORAGE TANKS

-

-

-

... More
PLATE WORK

-

-

-

... More
Plate work for Fixed Roof Tanks (Cone and Dome roof tanks) and covered Floating Roof tanks except Floating Roof: Transportation of plates to work site, fabrication and erection of shell, bottom (Sketch plates and annular plates including backing strips), cone roof, Dome roof, compression ring/knuckle plate, plate fabricated wind girders, wind girder opening, bearing plates for pipe supports, datum plates, shell manhole- necks, bolting and cover flanges for shell-man-holes, reinforcement pads for shell manholes, nozzle reinforcing pads, roof manhole-necks, bolting and cover flanges for roof manholes, reinforcing pads for Roof manholes, clean-out door assembly (including davit assembly), gusset- support for wind girders, Sump for drain nozzle, pads for all appurtenances and attachments, fabrication and installation of all items as per drawing, conducting tests such as vacuum test, MP/DP test, pneumatic test, oil penetrant examination, Grouting work (including the supply of grouting material, as required for the tanks installed on ring wall foundation) underneath the Annular/ bottom plate as per the specifications attached, tank hydrotest, etc. for shell, bottom and roof as specified, radiography including supply of films, all heat treatment specified in drawings/ specifications/ codes, providing all temporary structures, clamps, wedges, including arrangement of all materials, consumables, labour, equipment, machinery, tools, tackles etc. to complete the work in all respects as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of BANDR Engineer- in-Charge.

-

-

-

... More
IS 2062 Gr. E250 (A, BR, B0, C)

165

2604690

15786

... More
STRUCTURAL/PIPES

-

-

-

... More
STILL WELLS/ DIP PIPES : Fabrication, erection, inspection and testing of still well for gauge hatch, still well for level transmitter/ level switches, still well for temperature element including flanges on all still wells, dip pipes (process / instrumentation), pipe fittings, drilling of holes in still well/ dip pipes, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor.

-

-

-

... More
SS TP 316

0.8

57712

72140

... More
STRUCTURAL PIPES (CS GALVANISED): Fabrication, erection, inspection and testing of pipe specification for pipe handrails (CS and galvanised), arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work and instructions of Engineer- in-Charge.

-

-

-

... More
PIPES(CS GALVANIZED)

1.5

54105

36070

... More
APPURTENANCES

-

-

-

... More
Fabrication, installation, welding, radiography, heat treatment, inspection and testing as required for the following nozzles (reinforcing pads covered under plate work) pipe, nozzle flanges and blind / companion/matching flanges (including davit/ hinge assembly for Man way) wherever shown on drawings and standards along with gaskets and boltings conducting air pressure test for reinforcing pads, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications , standards, codes, scope of work, scope of supply and instructions of Engineer-in- Charge. All internal bolting shall be SS 304 as a minimum.

-

-

-

... More
Roof Nozzle 150 Class WNRF Type 3 Inch Size SA 105 Material

1

3310

3310

... More
Shell Nozzle 150 Class WNRF Type 10 Inch Size SA 105 Material

1

11033

11033

... More
Shell Nozzle 150 Class WNRF Type 2 Inch Size SA 105 Material

2

4414

2207

... More
Shell Nozzle 150 Class WNRF Type 3 Inch Size SA 105 Material

1

3310

3310

... More
Shell Nozzle 150 Class WNRF Type 4 Inch Size SA 105 Material

1

4414

4414

... More
Shell Nozzle 150 Class WNRF Type 6 Inch Size SA 105 Material

2

13240

6620

... More
Shell Nozzle 150 Class WNRF Type 14 Inch Size SA 105 Material

1

15447

15447

... More
Roof Nozzle 150 Class WNRF Type 4 Inch Size SA 105 Material

1

4414

4414

... More
Shell Nozzle 150 Class WNRF Type 24 Inch Size SA 105 Material

1

26480

26480

... More
Roof Nozzle 150 Class WNRF Type 24 Inch Size SA 105 Material

1

26480

26480

... More
Shell Nozzle 150 Class WNRF Type 8 Inch Size SA 182 Gr. F 316 Material

1

17653

17653

... More
GOOSE NECK VENT WITH WIRE MESH: Fabrication, installation, welding, radiography, heat treatment, inspection and testing as required for the (reinforcement pads covered under Plate work) goose neck vent with wire mesh (SS 304 as minimum) for the following vent materials.

-

-

-

... More
Size 16 Inch Material SA 106 Gr. B

1

47527

47527

... More
CALIBRATION Carrying out calibration of tanks including supply of strapping tapes, scaffolding wherever required, arranging the visit of competent authority, all accessories, labour, preparation and submission of calibration charts duly approved by Competent authority etc. and complete the work in all respect as per Codes, specifications, standards and instructions of BANDR Engineer-in-Charge

-

-

-

... More
Diameter (Meters) : upto 10 Height (Meters) : upto 10

1

37726

37726

... More
Diameter (Meters) : 10 to 25 Height (Meters) : 10

1

41918

41918

... More
DISTRIBUTOR / INTERNAL PIPE Fabrication of pipe as per drawings, installation of the same in position along with all supports, internal flanges duly bolted as per specifications, etc. as per standards, specifications, instruction of BANDR Engineer-in-Charge. All materials shall be supplied by BANDR

-

-

-

... More
Material SA 106 Gr. B

0.8

28516

35645

... More
Slot Dipping Device: Installation of "Slot Dipping Device" for the tankages mentioned in the data sheets/ drawings/ specifications as per the Specifications & Standards attached with the tender. Arrangement of machinery, tools & tackles, labour etc. to accomplish the installation of the same shall also be in the scope of Contractor. All materials shall be supplied by BANDR

-

-

-

... More
Size: 8 Inch Material: CS

1

8487

8487

... More
PAINTING OF TANKS

-

-

-

... More
PAINTING FOR CARBON STEEL AND LOW ALLOY STEEL TANKS

-

-

-

... More
External Surfaces (except underside of bottom plate): Surface preparation to SSPC-SP-10, application of primer and paint on all external surfaces of tanks including insulated tanks i.e. external shell, wind girders, appurtenances, roof tops including top side of floating roof of open tanks as well as covered floating roof tanks, external roof supporting structure, associated structural steel works, ladders, walkways, platforms, handrails, spiral stairway, rolling ladder and track, internal surface of shell above maximum liquid level exposed to atmosphere for open top or floating roof tanks as per painting system defined below and other requirements as specified in respective Engg. data sheets, stencilling tank no., capacity, name of stored product, painting Emblem as per the attached sample, including supply of metallic and non-metallic materials, primer and paint of approved quality, providing scaffolding, labour, equipment, consumables, etc. to complete the work in all respect as per applicable standard specifications, standards attached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials including thinner shall be supplied by Contractor.

-

-

-

... More
Design Temperature Range: -45 °C To 80 °C Primer: 1coat of F-9 @ 65-75μ DFT/coat + 1coat of P-6 @ 40μ DFT/ coat Finish Paint: 2 coats of F-6A/ F-6B @ 100μ DFT /coat + 1 coat of F-2 @ 40μ DFT/ coat Remarks: F-6 should be suitable for occasional water immersion

1800

1161000

645

... More
External Surfaces (underside of bottom plate): Surface preparation to SSPC-SP-10, application of primer and paint on underside of bottom plate (soil side) as per painting system defined below and other requirements as specified in respective Engg. data sheets including supply of metallic and non-metallic materials, primer and paint of approved quality, labour, equipment, consumables, etc. to complete the work in all respect, as per applicable standard specifications, standards attached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials including thinner shall be supplied by Contractor.

-

-

-

... More
Design Temperature Range: -45 °C To 80 °C Primer: 1 coat of F-7 @ 125μ DFT/ coat Finish Paint: 2 coats of F-7@ 125μ DFT/coat Remarks: F-7 should be suitable for immersion service of the products given

500

220000

440

... More
Internal Surfaces: Surface preparation to SSPC-SP-10, application of primer and paint on internal surface of bottom plate, shell full height, internal surfaces of cone/dome roof, roof structure, oil side surfaces of pontoons & deck plates and oil side surfaces of double decks, internal ladder, structural steel, internal support and internal accessories (except heating coil) as per painting system defined below and requirements as given in the respective engg. data sheets. Supply of metallic and non-metallic materials, labour, primer and paint of approved quality, equipment, consumables, etc. to complete the work in all respect, as per applicable specifications, standards attached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials including thinner shall be supplied by Contractor.

-

-

-

... More
Design Temperature Range: -45 °C To 90 °C Primer: 1 Coat of F-15 @80microns DFT/Coat Finish Paint 1 coat of F-15 intermediate coat @ 80μ DFT/coat + 1 coat of F-15 finish coat @ 80μ DFT/ coat; Remarks: -

295

153105

519

... More
Design Temperature Range: -45 °C To 60 °C Primer: F6A Finish Paint F6A Remarks: 1 Coat of F-6A@100micron DFT/Coat and 2 Coats of F-6A@100micron DFT/Coat

1700

923100

543

... More
EQUIPMENT ERECTION

-

-

-

... More
ERECTION OF BURIED EQUIPMENT : Transportation of vessels from Owner's storage point to worksite, repair/ touch up of finish paint, arrangement of all accessories, equipments, labour etc., placing/erection of vessel in trenches/pits including assembly of parts, subassemblies, aligning, verticality checking, grouting, tightening of foundation bolts, arranging all tools, tackles, machinery, consumables etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the BANDR Engineer-in-Charge.

-

-

-

... More
Equipment weighing less than 30 MT but 10 MT and Above

36

534708

14853

... More
WELDING & NDT OF CUT NOZZLES / SUMP / BOOT OF BURRIED VESSELS: Assembly of cut nozzles/Sump/Boot(as shown in Respective Engg. Data Sheet), vertically checking, alignment, Welding of cut nozzles , NDT such as 100% radiography ,UT , surface preparation of the weld seam portion, application of primer, painting, arranging all tools and tackles, machinery. Consumables, transportation/handling of equipment, labour etc to complete the work in all respects as per drawings & instruction of Engineer-in charge.

-

-

-

... More
MOC : Carbon Steel ,Nozzle size : 2"

2

4658

2329

... More
MOC : Carbon Steel ,Nozzle size : 4"

15

69870

4658

... More
MOC : Carbon Steel ,Nozzle size : 24"

2

55890

27945

... More
MOC : Carbon Steel ,Nozzle size : 28"

2

65206

32603

... More
EQUIPMENT PAINTING

-

-

-

... More
PAINTING (UNINSULATED EQUIPMENT) FOR CS / LTCS AND LOW ALLOY STEEL VESSEL

-

-

-

... More
Supply and application of field primers and finish paint on C.S., L.T.C.S. and low alloy steel vessels, columns, reactor, silencer, exchangers, air cooler structure and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required as per attached specification, providing scaffolding for all heights, labour, material, tools and tackles, consumables, supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge for all type of uninsulated equipment. The surface area is as per respective temperature ranges given below as per applicable specification. Note: Surface preparation and first coat of primer application shall be provided by equipment supplier. All materials including thinner shall be supplied by Contractor.

-

-

-

... More
Design Temperature Range: -45 °C To 80 °C Primer: 1 Coat of F-7@125micron DFT/Coat Finish Paint: 2 Coat of F-7@125micron DFT/Coat Remarks: Underground Vessels

240

105600

440

... More
Installation of valves

-

-

-

... More
installation of screwed valves as per piping material specification including fixing in position with threaded connections complete as per drawings, specifications and directions of BANDR Engineer-in-Charge.

-

-

-

... More
Globe valve for following nominal sizes and piping material class

-

-

-

... More
Dia 2 Inch Piping Material Class J2A

1

509

509

... More
Dia 1.25 Inch Piping Material Class J2A

1

425

425

... More
Modification Works

-

-

-

... More
MODIFICATION AND EXTRA WORKS ( IF ANY ) Cuting,bevelling,fitup,welding of different sizes of CS piping of all thicknesses in shop ,in position, on ground and at all elevations, transportation of pipes,fittings,flanges etc. from owner's storage point to work site/workshop,making necessary scaffolding,consumables,machinery,tools,tackles, labour and supervision including attending to repairs for completing the work as per instructions of Engineer -in -charge

-

-

-

... More
Flame cutting CS piping

40

7440

186

... More
Beveling CS piping

40

8480

212

... More
Fit-up and welding CS piping

40

28520

713

... More
NDT Testing

-

-

-

... More
RADIOGRAPHY :- Performance of radiographic inspection on piping of all types & thicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specifications and instructions of BANDR Engineer-in-Charge. Radiographs shall be submitted to the BANDR Engineer-in-Charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractor's fault and for additional radiography necessitated due to poor performance of contractor's welders shall be done at contractor's cost) Note: Unit for radiography quantity is 'Nos of circumferential weld joints'.

-

-

-

... More
FOR JOINTS THK. = 8MM (FOR CS OTHER THAN CLASS lV OF SPEC FOR NDT REQUIREMENT OF PIPING)

-

-

-

... More
Nominal Dia. 3 Inch

3

1584

528

... More
Nominal Dia. 4 Inch

11

7744

704

... More
Nominal Dia. 6 Inch

26

27456

1056

... More
Nominal Dia. 8 Inch

7

9856

1408

... More
Nominal Dia. 12 Inch

19

40109

2111

... More
Nominal Dia. 2 Inch

7

3696

528

... More
Nominal Dia. 1 Inch

1

528

528

... More
Nominal Dia. 10 Inch

3

5280

1760

... More
Nominal Dia. 16 Inch

7

19705

2815

... More
Nominal Dia. 14 Inch

9

22167

2463

... More
Nominal Dia. 24 Inch

3

12669

4223

... More
Restriction Orifice

-

-

-

... More
Installation of Restricted orifice plate as per data sheet, specifications, drawings and directions of BANDR Engineer-in-Charge. For following nominal sizes of pipes and Piping material class.

-

-

-

... More
Nominal Dia. 6 Inch Piping Material Class A94A

2

17498

8749

... More
Portable/ trolley mounted Extinguishers

-

-

-

... More
Installation of portable DCP ( Dry Chemical Powder Type) extinguisher including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification and directions of BANDR Engineer-in-Charge.

-

-

-

... More
Capacity in Kg 9

12

14724

1227

... More
Installing in position, trolley mounted DCP (Dry Chemical Powder Type) extinguisher including transporting to worksite, placing in position including all accessories and all labor and material etc. complete as per drawings, specification and directions of BANDR Engineer-in-Charge.

-

-

-

... More
Capacity in Kg 75

2

13326

6663

... More
Installation of portable CO2 extinguishers including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification, data sheet and directions of BANDR Engineer-in-Charge.

-

-

-

... More
Capacity in Kg 4.5

63

81270

1290

... More
Capacity in Kg 2

2

1718

859

... More
Painting of A/G pipes and valves

-

-

-

... More
Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per painting specification, drawings and direction of BANDR Engineer-in-Charge for all types of un insulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of BANDR Engineer-in-Charge. Notes: 1. All joints (fabrication as well as erection joints) shall be left unpainted till hydro testing. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines.

-

-

-

... More
Painting of uninsulated surfaces for 'Industrial ' environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following pipe sizes

-

-

-

... More
Nominal Dia. 0.75 Inch

3

180

60

... More
Nominal Dia. 1 Inch

100

7600

76

... More
Nominal Dia. 12 Inch

650

415350

639

... More
Nominal Dia. 10 Inch

3

1620

540

... More
Nominal Dia. 6 Inch

112

37296

333

... More
Nominal Dia. 4 Inch

63

14238

226

... More
Nominal Dia. 8 Inch

30

12990

433

... More
Nominal Dia. 14 Inch

90

63270

703

... More
Nominal Dia. 16 Inch

45

36180

804

... More
Nominal Dia. 2 Inch

7

833

119

... More
Nominal Dia. 3 Inch

45

7830

174

... More
Nominal Dia. 24 Inch

41

49405

1205

... More
Painting of uninsulated surfaces for 'Industrial ' environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following valve sizes

-

-

-

... More
Nominal Dia. of valve 0.75 Inch

3

276

92

... More
Nominal Dia. of valve 12 Inch

3

3405

1135

... More
Nominal Dia. of valve 6 Inch

27

15957

591

... More
Nominal Dia. of valve 1 Inch

3

276

92

... More
Nominal Dia. of valve 8 Inch

1

770

770

... More
Nominal Dia. of valve 14 Inch

9

11241

1249

... More
Nominal Dia. of valve 16 Inch

3

4281

1427

... More
Nominal Dia. of valve 2 Inch

2

424

212

... More
Nominal Dia. of valve 24 Inch

1

2141

2141

... More
Nominal Dia. of valve 3 Inch

1

312

312

... More
Fabrication and Erection of piping (underground)

-

-

-

... More
FABRICATION AND ERECTION OF PIPING (SPEC. NO.6-65-0030 and 6-44-0012) : Laying and joining of Carbon Steel pipes and specials underground including transportation of all material from Owner's storage point to worksite, earthwork in excavation in all types of soil EXCLUDING SOFT ROCK AND HARD ROCK for pipe trenches, saddles, etc. including dewatering of rain and /or sub soil water, shoring & strutting if required, dressing of sides, levelining, grading & ramming of bottom of trench, cutting of pipes if required, fitup, edge preparation, providing corrosion protection tape coating as per specification, on pipes and specials, laying the pipes in trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments and fittings like elbows, reducers, tees, flanges, spectacle blinds and spacer blinds etc., providing reinforcing pads as per piping material specification, fixing of nuts, bolts, gaskets and washers, welding, corrosion protection coating of field joints, cutting of road wherever required and making good the same, testing for the corrosion protection coating as per specification, cleaning and flushing by water/ compressed air, hydrostatic/ pnuematic testing of the system, flushing, backfilling the trenches with select material from available excavated soil including re-excavating the deposited soil excavated earlier, breaking clods and laying in layers of 15 cm compacted thickness, watering, compacting with mechanical means like vibro rammers etc. to 90% of dry density as per IS:2720 Part-VII, disposal of surplus earth/ unserviceable material to demarcated area anywhere within the complex limit etc. complete as per drawings, specifications and instructions of BANDR Engineer-in-Charge including connecting the pipes to manhole, including return of all unused / scrap pipe to owner's storage point (Pipes and fittings shall be supplied by owner as free issue material.) (Depth of excavation for pipe trench shall be upto 3.0m)

-

-

-

... More
Carbon Steel Piping (Non IBR), Thickness =10 mm

-

-

-

... More
Fabrication, For the following nominal sizes

-

-

-

... More
NB upto 1.5 inch

7

3563

509

... More
NB 2 inch - 6 inch

835

387440

464

... More
NB 8 inch - 14 inch

820

380480

464

... More
NB 16 inch - 24 inch

75

34800

464

... More
Erection including corrosion protection coating, for Water System (Pressure Piping), For following Nominal Sizes

-

-

-

... More
NB upto 1.5 inch

7

2674

382

... More
NB 2 inch - 6 inch

150

45300

302

... More
NB 8 inch - 14 inch

980

255780

261

... More
NB 16 inch - 24 inch

360

90720

252

... More
Erection including corrosion protection coating, for Waste Water Collection System (Gravity Flow), for following Nominal Sizes

-

-

-

... More
NB 2 inch - 6 inch

550

166100

302

... More
NB 8 inch - 14 inch

85

22270

262

... More
Fabrication and Erection of piping (Above ground)

-

-

-

... More
PIPING (ABOVE GROUND): Transportation of all piping items from owner's storage point to work site/workshop, fabrication including cutting, edge preparation (including grinding the edges of pipe, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required), fitup, bending, preheating wherever required, welding, threading, and laying of pipes of all type and thickness over pipe sleepers, overhead on racks and at all elevations, connecting with equipment nozzles, strainers, orifice assemblies, tapping for pressure gauges etc., fixing of gaskets, bolts, nuts including application of torque wherever required and all other inline instruments and fitting like elbows, reducers, tees, vents, drains, SW valves upto 1.5 NB, alignment, cleaning & flushing by water/compressed air, hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified, draining, drying by compressed air completing all such works in all respects (including preparation of isometrics as mentioned in the scope of work for the job) as per drawings, specifications and instruction of BANDR Engineer-in-Charge.

-

-

-

... More
Carbon Steel Piping (Non IBR), Thickness =10 mm

-

-

-

... More
Fabrication, For the following nominal sizes

-

-

-

... More
NB upto 1.5 inch

3

1422

474

... More
NB 2 inch - 6 inch

1100

473000

430

... More
NB 8 inch -14 inch

3700

1591000

430

... More
NB 16 inch -24 inch

1550

666500

430

... More
Erection , for Water System (Pressure Piping), For following Nominal Sizes

-

-

-

... More
NB upto 1.5 inch

7

1246

178

... More
NB 2 inch - 6 inch

700

110600

158

... More
NB 8 inch -14 inch

10000

1580000

158

... More
NB 16 inch -24 inch

2000

316000

158

... More
Fabrication and Erection of piping (Above ground)

-

-

-

... More
Fire water spray/ sprinkler/ detection system G.I. PIPING A/G (Screwed)

-

-

-

... More
Laying ABOVE GROUND mild steel galvanized pipes for Fire water spray system/ sprinkler system/ detection system as per piping material specification including supply of Teflon tapes, white lead etc., cutting the pipes to required lengths, making threads, including laying of pipes on pipe rack, sleepers, T-supports, erection of piping on equipments, pumps etc. including joining of pipes and fittings with threaded/flanged connections, including installation of spray nozzles, Quartzoid bulb detectors, restriction orifice, flanges, break-up flanges, gaskets and bolts, hydrostatic testing of the piping including supply of necessary fittings etc. complete as per specifications, drawings and instructions of BANDR Engineer-in-Charge.(Spray nozzles, restriction orifice, flanges and break-up flanges shall be paid separately under separate SOR/ shall be given as free issue to the contractor.) For following nominal sizes and piping material class.

-

-

-

... More
Dia. 4 Inch PMS J2A

60

50940

849

... More
Dia. 1 Inch PMS J2A

97

24735

255

... More
Dia. 6 Inch PMS J2A

30

38220

1274

... More
Installation of valve assembly, flange assembly etc.

-

-

-

... More
Installation of valve assembly consisting of valve, 2 no. flanges, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of BANDR Engineer-in-Charge.

-

-

-

... More
Gate valve assembly for following nominal sizes and piping material class

-

-

-

... More
Dia. 0.75 inch PMS A94A

3

1275

425

... More
Dia. 8 Inch PMS A94A

1

2716

2716

... More
Dia. 6 Inch PMS A94A

27

54999

2037

... More
Dia. 2 Inch PMS A1A

1

679

679

... More
Dia. 4 Inch PMS A1A

1

1358

1358

... More
Dia. 12 Inch PMS A94A

3

12219

4073

... More
Dia. 14 Inch PMS A94A

5

23765

4753

... More
Dia. 16 Inch PMS A94A

3

16296

5432

... More
Dia. 2 Inch PMS A94A

1

679

679

... More
Dia. 3 Inch PMS A94A

2

2716

1358

... More
Dia. 24 Inch PMS A94A

1

8148

8148

... More
Dia. 8 Inch PMS A96A

2

5432

2716

... More
Dia. 12 Inch PMS A96A

1

4073

4073

... More
Check valve assembly for following nominal sizes and piping material class

-

-

-

... More
Dia. 14 Inch PMS A94A

4

19012

4753

... More
Dia. 2 Inch PMS A94A

1

2037

2037

... More
Fabrication and installation of strainers

-

-

-

... More
Fabrication and installation of strainers as per drawings etc. complete as per specifications and directions of BANDR Engineer-in-Charge.

-

-

-

... More
T-type strainers for following nominal size and piping material class

-

-

-

... More
Dia. 4 Inch PMS A1A

1

8296

8296

... More
Dia. 16 Inch PMS A94A

2

27158

13579

... More
Dia. 3 Inch PMS A94A

1

3395

3395

... More
fire fighting equipment's

-

-

-

... More
Installation, testing and commissioning of following firefighting equipment as per relevant specifications, data sheet, drawing, including transporting the equipment to worksite, fixing of nuts, bolts, washers, gaskets, welding needed for fixing the equipment with matching flange etc. all complete as per drawings, specifications, standards, data sheet and direction of BANDR Engineer-in-Charge.

-

-

-

... More
First Aid hose reel wall mounted type

1

1969

1969

... More
Hose box cabinet Type-II (Wall mounted type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall

1

849

849

... More
Hose box cabinet Type-II (self-supporting type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall

11

14014

1274

... More
Variable flow Water cum foam monitor of 500/750/1000 GPM capacity

3

38193

12731

... More
Stand Post Type Fire Hydrant without Pumper Connection

22

28028

1274

... More
Supply of medium velocity spray nozzles with 1/2" NPT fixing arrangement with MS half coupling to Owners storage point, testing etc. all complete as per specification, drawings, data sheet and directions of BANDR Engineer-in-Charge. For nozzle of following K factor

-

-

-

... More
K factor 51

45

21060

468

... More
Painting of A/G pipes and valves

-

-

-

... More
PAINTING :- Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per painting specification, drawings and direction of BANDR Engineer-in-Charge for all types of un insulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of BANDR Engineer-in-Charge. Notes: 1. All joints (fabrication as well as erection joints) shall be left unpainted till hydro testing. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines.

-

-

-

... More
Painting of uninsulated surfaces for ' Industrial ' environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following valve sizes

-

-

-

... More
Dia 4 Inch

1

401

401

... More
Dia 2 Inch

1

212

212

... More
Miscellaneous Items

-

-

-

... More
Supplying, fabrication and fixing in position carbon steel tube vent pipes (As per PMS) 100mm dia. with specials and necessary fittings including cutting to required length, edge preparation, jointing by welding, making and fixing single joint mitre bends wherever required, earth work in excavation and back filling, fixing in concrete blocks, providing painting with 2 coats of chlorinated rubber zinc phosphate primer @ 40μ DFT per coat and finished paint of 2 coats of chlorinated rubber paint @ 40 μ DFT per coat on above grade portion and supplying and fixing clamps, corrosion protection tape coating as per spec. no. 6-79-0011 or approved job specification for underground portion complete in all respects including all labour and materials, etc. as per drawings specifications and direction of BANDR Engineer-in-Charge.

-

-

-

... More
BELOW grade level / Pavement level, PMS -A96A

7

21462

3066

... More
ABOVE grade level / Pavement level, PMS-A96A

3

8826

2942

... More
Design, engineering, procurement, supply of all materials and equipment, machinery, civil, structural, electrical, mechanical, instrumentation, piping works including painting works, tape coating on U/G piping, commissioning spares and tools/tackles as per scope of work, specifications, drawings, data sheets etc. and as per directions of BANDR Engineer-in-Charge for Auto Actuated High Velocity Spray System on Transformers including taking approval of the complete system from TAC accredited agency any other agency appointed by insurance company /Client. Unloading at site, handling, transportation from store to work site, storage at site, fabrication, construction, assembly at site, supply of all labour, installation, field works including structural, electrical, mechanical, instrumentation, piping works and supports, testing, pre-commissioning, painting, commissioning and any other activity required to complete the works in all respects including performance guarantee run, handing over to client as per enclosed scope of work, drawings, specifications, instructions to vendors, data sheets and as per directions of Engineer in- Charge. Supply of mandatory spares as per specifications enclosed list/instructions to vendor as per scope of work and specification, drawings and documents as per attached vendor data requirement for all supplies and services etc. complete.

-

-

-

... More
For Transformer Tag no. 4U38-TR-01

1

1819013

1819013

... More
For Transformer Tag no. 4U38-TR-02

1

1819013

1819013

... More
STRUCTURAL STEEL WORKS SPEC NO. 6-68-0006

-

-

-

... More
General Steel Works - Non FIM Items

-

-

-

... More
Supplying, transporting, storing, fabricating & erecting in position and testing/examining bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E250BR / E250B0 (confirming to per IS:2062) at all locations and levels UPTO & INCLUSIVE OF 20m ABOVE HPP/ FGL, including all built up sections/ compound sections made out of rolled sections and/or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipment, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Non shrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per EIL Specification No. 6-79-0020 (or as per Job Specification, wherever applicable) after fabrication etc., all complete. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE.

29

2538370

87530

... More
Painting - Non FIM Items

-

-

-

... More
Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 9.2 of Table 9.0 of EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable) over the coat of shop primer already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat as per Sl. No. 7.2.1 of Table 7.2 of EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable), for steel structures (excluding ladders, spiral stairways & hand rails) at all location & levels, all complete as specified, for OFFSITE (INLAND) areas considering environment classification as INDUSTRIAL. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE.(Unit rate based on Structural steel weight).

30

182670

6089

... More
Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 8.1 of Table 8.0 of EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable) for painting over the coat of shop primer & galvanisation already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat, for LADDERS, SPIRAL STAIRWAYS & HAND RAILS at all location & levels, all complete as specified. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE. (Unit rate based on weight of steel).

0.8

5982

7478

... More
Barricading Structure - Non FIM Item

-

-

-

... More
Supplying, transporting, storing, fabricating & erecting in position and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS FOR BARRICADING, of Grade E250A / E250BR / E250B0 (conforming to IS:2062) and/ or CFSHS/ CFRHS of Grade YSt 310 (conforming to IS:4923) and/ or CFCHS of Grade YSt 310 (conforming to IS:1161) at all locations and levels, including all built-up sections/ compound/ hollow/ tubular sections made out of rolled sections and/ or plates/ bent plates in all types of structural frameworks for isolating the construction area, cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Non-shrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting and applying pre-erection/ shop primer as per EIL Specification No. 6-79-0020 (or as per Job Specification, wherever applicable) after fabrication etc., AND maintaining the structure during project execution AND dismantling, removing & taking away all materials outside the plant boundary after completion of the project, to the complete satisfaction of Engineer-in-charge all complete as per the direction of Engineer-in-Charge. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE.

3.5

295960

84560

... More
MS Chequered Plates - Non FIM Items

-

-

-

... More
Supplying, fabricating and erecting in position at all levels and locations bolted, screwed and/or welded M.S. CHEQUERED PLATES of any thickness in walkways, platforms, stair treads, any other place as directed etc. including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing, welding, preparation and submission of fabrication drawings and preparing the surfaces for painting and applying shop primer as per EIL Specification No. 6-79-0020 (or Job Specification, wherever applicable) after fabrication etc. all complete as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE).

2.5

205072

82029

... More
MS Grating Cat. A,B - Non FIM Items

-

-

-

... More
Supplying, fabricating and erecting in position at all levels and locations ELECTROFORGED GALVANISED GRATING (purchased from approved manufacturer by the Contractor) conforming to EIL Standard No. 7-68-0697 (in walkways, platforms, stair treads etc.) and EIL Standard No. 7-65-0206 (in catch basins, drains, etc.) including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing with manufacturer's supplied galvanised clamps, preparation and submission of fabrication drawings, all complete as specified and directed (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE).

2.5

247340

98936

... More
Hand Railing 1000mm - Non FIM Items

-

-

-

... More
Supplying, fabricating and fixing in position at all locations 1000mm high INCLINED HAND RAILING (for staircases) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 8.1 of Table 8.0 of EIL SPEC. 6-79-0020 (or as per Job Specification, wherever applicable), preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed).

70

135520

1936

... More
Supplying, fabricating and fixing in position at all locations 1000mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 8.1 of Table 8.0 of EIL SPEC. 6-79-0020 (or as per Job Specification, wherever applicable), preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed).

170

327930

1929

... More
Hand Railing 500mm - Non FIM Items

-

-

-

... More
Supplying, fabricating and fixing in position at all locations 500mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 8.1 of Table 8.0 of EIL SPEC. 6-79-0020 (or as per Job Specification, wherever applicable), preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTOR'S SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed).

30

48450

1615

... More
Mechanical Anchor fastners - Non FIM Items

-

-

-

... More
"Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 12mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer's specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed."

15

7260

484

... More
"Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 16mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer's specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed."

15

11880

792

... More
"Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 20mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer's specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed."

15

15840

1056

... More
Chemical Anchor Fastner

-

-

-

... More
"Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be used with the help of dispenser, of 12mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer's specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed."

15

46185

3079

... More
"Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be used with the help of dispenser, of 16mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer's specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed."

15

49650

3310

... More
"Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be used with the help of dispenser, of 20mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturer's specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed."

15

56745

3783

... More
Steelwork - Non FIM Items

-

-

-

... More
Mechanical works

-

-

-

... More
Supplying, fabricating and erecting in position MS plates as per detailed drawings, conforming to grade A of IS:2062 on top of all RCC pedestals supporting the sliding saddles of equipments, including cutting, straightening where necessary, rounding rounding unfinished edges by grinding, machining the exposed top surface, making necessary bolt holes, providing and laying ready mixed free flow non-shrink grout below the base plate at all levels & locations, machining top surfaces etc. all complete and as shown and directed.

2

172338

86169

... More
SAFETY (REFER EIL SPECIFICATION)

-

-

-

... More
Safety Structures - Non FIM Items

-

-

-

... More
Covering of existing openings in buildings with 6 mm thick MS chequered plates by stitch welding (12 mm @ 500 mm centres) to the existing steel framework and in case existing MS framework is not available, by providing necessary anchor fastner (Mechanical) in concrete/ brick wall etc., including cutting, grinding edges, hoisting, fixing in position all complete as per the directions of Engineer-in-Charge. Rate is inclusive of supply of all materials and consumables.

8

1056

132

... More
Providing and fixing double scaffolding system of any height made with 40 mm dia MS tube 1.5 m centre to centre, horizontal & vertical tubes joining with MS tubes, MS tube challies, MS clamps and MS staircase system in the scaffolding for working platform/ staircase etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc., wherever required for inspection of work at required locations with essential safety features for the workmen etc., all complete as per directions and approval of Engineer-in-charge. (Height shall be measured from Floor/ platform from where scaffolding is erected) including providing Aluminium ladders for safe acess of workers.

630

91980

146

... More
Providing of steel scaffold stair tower system with minimum 800 mm wide flights, landings at every 1.5 to 2.0 m height, handrailing around flights and landings for safe access upto a height of 12.0 m, all complete including supply of all materials, tools & tackles, manpower etc., at the location directed by Engineer-in-Charge on monthly rental basis. Rental charges shall be payable after completion of erection of the system and acceptance by the Engineer-in-Charge. Rates shall also be inclusive of dismantling of the system and taking out all materials from the project permises as directed by the Engineer-in-Charge. Rate quoted shall be for Running Meter (Height) per month.

20

75640

3782

... More
Supply of Safety Personnel

-

-

-

... More
Supply of HSE personnel SAFETY STEWARD over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws).

12

334728

27894

... More
Supply of HSE personnel SAFETY SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws).

12

430356

35863

... More
Supply of HSE personnel SAFETY OFFICER over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws).

12

717264

59772

... More
Supply of HSE personnel HOUSE-KEEPING SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws).

12

239088

19924

... More
PIPELINES

-

-

-

... More
INSTALLATION OF STEEL PIPELINE

-

-

-

... More
Removal of 3LPE Coating from Free-Issue Line Pipes, as required and as per instructions of Engineer-in-Charge.

40

35200

880

... More
Laying/ Installation of line pipe, associated fittings and accessories, etc. as per specifications, standards, drawings, other provisions of Contract and Instructions of BANDR Engineer-in-Charge, including but not limited to carrying out the following: "Receiving and taking-over", safe handling, loading, transportation and unloading of Owner supplied Free Issue Materials (as applicable) from designated place(s) of issue/ dump site(s) to Contractor's own stock-yard(s) including stringing the pipeline in Right-of-Use (ROU) / Right of Way (ROW), Arrangement of all additional land required for Contractor's storage, fabrication, access for construction (other than Owner provided ROU; supply of all materials (except Owner supplied materials, as applicable), consumables, equipment, labour, etc; Staking and installation of construction markers, clearing, grubbing, grading (as required) of Right-of-Use (ROU) / Right of Way (ROW); Cutting Trees, if required; Counting the number and type of trees cut in presence of DFO/ concerned authorities and keeping record thereof; blasting, chiseling or otherwise cutting etc.; Providing Warning Devices (Mat/ Tape or Mesh), as required; Carrying out repairs of pipe and coating defects not attributable to Owner; Thorough internal cleaning of all pipes by suitable methods to remove debris, shots, grits etc.; Stringing of line pipes along ROU including providing straw bags, soft padding/sand padding; Aligning, bending, cutting and beveling (as required) of pipes for welding and field adjustments, NDT of re-beveled area, welding, carrying out destructive & non- destructive testing of welds required as per approved NDT specifications (including radiography) and providing all requisite equipment, labour, supervision, materials, films, consumables etc.; carrying out repairs of weld joints as required, carrying out re- radiography and other non-destructive tests on repaired joints, etc.; Installation of carrier pipe including concrete coated pipes (wherever required) at all crossings including roads/ canals/ nala/ water crossings etc. (except at crossings that are specifically covered separately in this SOR) by open cut or Jacking/ boring method including pre-testing as required; Carrying out installation of carrier pipe in the casing pipe at cased crossings (excluding supply and installation of casing pipes, covered separately);

-

-

-

... More
( CONTINUE FROM ABOVE) Coating of all field weld joints, long radius bends, buried fittings etc.(as applicable); Lowering the pipelines in trench including providing sand bag separators for parallel pipelines at the specified spacing (when applicable), Supply and installation of slope breaker as per specifications and drawings in steep slope areas, wherever required; Carrying out hydrostatic testing including air cleaning, flushing, filling, gauging, pressurization of complete pipeline in various test sections as approved by BANDR Engineer-in-Charge to the specified test pressure, providing all equipment, pumps, fittings, instruments, dead weight tester, all types of pigs etc., and services, supervision, labour, consumables, arranging adequate quantity of water of suitable quality required for hydrostatic testing including supply of corrosion inhibitor, air, etc. as required, locating of leaks and rectification of defects attributable to Contractor, re-testing after rectification, successful completion of hydro-testing of pipeline (Controlled De-watering etc. covered elsewhere in the SOR); including all tie-in(s) with the pipeline/ piping installed by others including cutting of test header, re- beveling as required; Carrying out all temporary, ancillary, auxiliary works and all incidental works required to make the pipeline ready for pre-commissioning; Repair of defects recorded during EGP/gauge plate run or otherwise including cutting, beveling, welding, NDT (including Radiography/ X Ray check shorts, as applicable), field joint coating etc. as applicable; Final clean-up and restoration of right of use/ right of way including obtaining work permits/ NOC from respective statutory authorities as required and disposal of debris and returning all surplus material to designated disposal areas/ Company storage yard, as directed by BANDR Engineer-in-Charge; Restoration of land, facilities and boundary wall etc. at associated facilities dismantled/damaged by the Contractor during construction; Obtaining work permits/ NOC from various statutory authorities having jurisdiction and complying with all stipulation/conditions/recommendation of the said authorities; Preparation of As-Built drawings, pipe-book and other records. SOR shall be read in conjunction with drawings, scope of work, specifications, standards and other provisions of contract document. All above works for buried pipeline as per following details:

-

-

-

... More
Scope of Work Installation of Pipeline (Line Pipe Free issue from Owner) OFC Conduit to be installed No Pipe Material Grade API 5L Gr. X-70 PSL 2 Pipe OD 660 mm Type of External Coating 3LPE Type of Internal Coating NIL Type of Soil/Strata Normal Strata (Soft Soil/ Sand/ Clay/ Silty Sand/ Silty Clay etc.) Type of Terrain Generally Flat Wall Thickness 9.2 mm

255

3188265

12503

... More
Scope of Work Installation of Pipeline (Line Pipe Free issue from Owner) OFC Conduit to be installed No Pipe Material Grade API 5L Gr. X-70 PSL 2 Pipe OD 660 mm Type of External Coating 3LPE Type of Internal Coating NIL Type of Soil/Strata Normal Strata (Soft Soil/ Sand/ Clay/ Silty Sand/ Silty Clay etc.) Type of Terrain Generally Flat Wall Thickness 12.8 mm

82

1096258

13369

... More
HIRING OF MANPOWER FOR PRE-COMMISSIONING & COMMISSIONING ASSISTANCE: Providing Skilled, Semi-Skilled & Unskilled manpower for carrying out Pre-commissioning & assistance for commissioning activities as per the direction of BANDR Engineer-in-Charge including deployment of tools, tackles & machinery along with supply of consumables as per SOW doc. no. B302-000-83-41-SOW-9515. Note: This manpower shall be utilized for Pre-commissioning & Commissioning assistance over and above that already described elsewhere in this SOR. One man day is 12 hour duty.

-

-

-

... More
Skilled man power - Welder, Millwright fitter

113

199897

1769

... More
Semi Skilled man power - Pipe fitter, Gas cutter, Rigger, Electrician (for welding M/C)

113

185094

1638

... More
Un-skilled man power - Helper/ Khalasi

150

208800

1392

... More
BACKFILLING WITH SELECT SOIL

-

-

-

... More
Unit rate over and above item no. 01PP.1.1.1/ 01PP.2.1.1 (as applicable) for supply of specified and approved quality of sand (for station approaches) or approved quality of cohesion-less soil as backfill material like graded sand, morrum, silty sand etc. (for seismic zones along pipeline route) including supply of sand or approved quality of backfill material like graded sand /other types of soil etc. in place of available excavated material and/ or other suitable soil as per applicable standards/ specifications, including backfilling of excavated trench for specified length after laying of pipeline and optical fiber cables/ cable conduit, including transportation of backfill material over all distances and disposal of surplus excavated soil. All work shall be executed as per following details:

-

-

-

... More
Type of Backfill Station Approach Pipe OD 660 mm Distance of Transport Not Applicable

40

25280

632

... More
LEAKS/ BURSTS (ATTRIBUTABLE TO OWNER)

-

-

-

... More
Repair of Leaks/ Bursts in Pipeline All works for locating any major leak/burst (occurred during hydrostatic testing) or any minor leak by sectionalizing or any other methods which cannot be located by visual means, including necessary repairing/ replacing defective pipe length, including cutting and removing out defective pipes, transportation, pretesting of replacement pipe and welding into mainline, NDT of welds and re-beveled area, repair and re-testing of defective welds, coating/ painting of welded joints, clean-up, retesting the pipeline/ pipe segment including providing all necessary equipment, labour, materials, consumables and inputs other than Owner supplied materials and performing all works as per drawings, scope of work, specifications, standards enclosed with the Contract and directions of BANDR Engineer-in-Charge. Note: 1. This rate is applicable for manufacturing defects in Company/ Owner supplied material only.

-

-

-

... More
Type of Leak Major Leak (detected by visual method) Pipe OD 660 mm

1

6210

6210

... More
Repair of Leak/ Burst in Terminal Piping All works for repair of leak/burst (occurred during hydrostatic testing) by necessary repairing/ replacing defective pipes/ fittings/ flanges etc., including cutting and removing out defective items, transportation, welding, NDT of welds and re-beveled area, repair and re-testing of defective welds, coating/ painting of welded joints, clean-up, retesting the pipe segment including providing all necessary equipment, labour, materials, consumables and inputs other than Owner supplied materials and performing all works as per drawings, scope of work, specifications, standards enclosed with the Contract and directions of Engineer-in-Charge. Note: 1. This rate is applicable for manufacturing defects in Company/ Owner supplied material only.

82

8528

104

... More
IDLE TIME PRESERVATION WORKS

-

-

-

... More
Idle time preservation of Pipeline and Associated facilities: Preservation of complete pipeline and associated facilities and its maintenance by filling and pressurizing with nitrogen including supply and maintenance of nitrogen or by filling and pressurizing with corrosion inhibited water including supply and maintenance of water with regular dosing of inhibitor to maintain the effectiveness of the inhibitor water (along with disposal of corrosion inhibited water at a proper/ suitable location, after due preservation works) and supply of all consumables, all equipment, man- power, etc., complete as per the requirements of specifications, scope of work, standards, other provisions of Contract document and instructions of Engineer-in- Charge as per following details:

-

-

-

... More
Type of Preservation By Filling Corrosion Inhibited Water Pressure (Bar(g)) 2.0 Pipe OD 660 mm Period 3 to 6 Month

300

18600

62

... More
Type of Preservation By Filling Corrosion Inhibited Water Pressure (Bar(g)) 2.0 Pipe OD 660 mm Period 6 to 9 Month

300

18600

62

... More
Type of Preservation By Filling Corrosion Inhibited Water Pressure (Bar(g)) 2.0 Pipe OD 660 mm Period 9 to 12 Month

300

18600

62

... More
Type of Preservation By Filling Corrosion Inhibited Water Pressure (Bar(g)) 2.0 Pipe OD 660 mm Period Up to 3 Month

300

51300

171

... More
Idle time preservation of Terminal and associated facilities: Preservation of complete terminal and associated facilities and its maintenance by filling and pressurizing with nitrogen including supply and maintenance of nitrogen or by filling and pressurizing with corrosion inhibited water including supply and maintenance of water with regular dosing of inhibitor to maintain the effectiveness of the inhibitor water (along with disposal of corrosion inhibited water at a proper/ suitable location, after due preservation works) and supply of all consumables, all equipment, man- power, etc., complete as per the requirements of specifications, scope of work, standards, other provisions of Contract document and instructions of Engineer-in- Charge as per following details

-

-

-

... More
Type of Preservation By filling Corrosion Inhibited Water Pressure (Bar(g)) 2.0 Period 3 to 6 Month

9200

82800

9

... More
Type of Preservation By filling Corrosion Inhibited Water Pressure (Bar(g)) 2.0 Period Up to 3 Month

9000

135000

15

... More
Type of Preservation By filling Corrosion Inhibited Water Pressure (Bar(g)) 2.0 Period 6 to 9 Month

9500

85500

9

... More
Type of Preservation By filling Corrosion Inhibited Water Pressure (Bar(g)) 2.0 Period 9 to 12 Month

9800

88200

9

... More
PRE-COMMISSIONING AND COMMISSIONING ASSISTANCE FOR PIPELINES

-

-

-

... More
Carrying out pre-commissioning activities and pre-commissioning checks to the specified acceptance criteria, making the entire pipeline system including stations ready for commissioning, providing assistance during the complete duration of commissioning operations, supply of all equipment, man-power, consumables, including all type of pigs and required quantity of nitrogen (if & as required), materials for all temporary works and performing all associated works, complete as per the relevant specifications, scope of work, standards, other provisions of Contract document and instructions of BANDR Engineer-in-Charge

-

-

-

... More
Pre-Commissioning Works as per details: Type of Activity Dewatering Pipe OD 660 mm

289

36414

126

... More
Pre-Commissioning Works as per details: Type of Activity Swabbing Pipe OD 660 mm

289

49708

172

... More
Commissioning Assistance : All works for Commissioning assistance as per details below: Pipe OD 660 mm

289

336685

1165

... More
PIPING WORKS IN DESPATCH/ RECEIPT/ INTERMEDIATE PUMPING/ COMPRESSOR/ INTERMEDIATE PIGGING/ SV/ SIV/ BLOCK VALVE/ TAP OFF STATIONS

-

-

-

... More
FABRICATION, ERECTION, INSTALLATION AND TESTING OF PIPING

-

-

-

... More
All works for installation of all above ground terminal/ station piping at all elevations and below ground at all depths for DT/ RT/ IP/ IPS/ Compressor/ Sectionalizing Valve Station(s)/Station Block Valves/Tap off/In Stations including tapping(s) inside terminals/ station as indicated in Scope document, in all type of terrain and soil including receiving and taking over of all Owner supplied materials from Owner's designated place(s) of issue, transportation including loading, unloading, handling from Owner's designated place(s) of issue to Contractor's owned/ hired stock yard(s)/ work site(s)/ work shop(s) including arranging all necessary intermediate storage area(s) thereof, as required; supply of all materials (except those specified subsequently in SOR) equipment, consumables etc. as defined in Contractor's scope of supply, and their transportation to the work site(s); performing all above ground/buried piping fabrication works including cutting, edge preparation, (inclusive of grinding the edges of pipes, fittings, flanges etc. to match with the matching edges of uneven/ different thickness wherever required), fit up, bending, pre-heating wherever required, welding, threading etc.; erection of pipes of all types and thickness over sleepers, overhead racks and at all other elevations; hook-up with equipment nozzles; installation and supporting of all type of valves up to size of 1.5" NB, all types of inline/ online instruments such as pressure/thermal safety valves(other than those covered separately in subsequent SOR), fittings of all sizes i.e. flow tees, insulating joints, blow down type QOEC, LR Bends, Pig Signalers, elbows, reducers, tees, 'O' lets, flanges, blind flanges, spectacle blinds, spacers and blinds, tappings for pressure instruments, thermo wells, hoses and hose couplings of all sizes, as applicable, sample connections, flame arrestors as applicable, vents and drains required for process and hydro-testing purposes etc.;

-

-

-

... More
(CONTINUE FROM ABOVE) fixing of all types of gaskets (including gaskets for RJ flanges), stud bolts and nuts, jack screw etc. of all sizes including torque tightening as applicable; Carrying out all temporary, ancillary & auxiliary piping works; fabrication of strainers of sizes up to 1.5” NB; carrying out non-destructive testing (excluding specific radiography works covered subsequently in SOR) including radiography, magnetic particle/ liquid penetration etc. as required; hook-up with existing piping/pipeline installed by others as per drawings wherever required; weld repairs/retesting; cleaning and flushing by water/ compressed air, carrying out hydrostatic test, pneumatic test, valve functional test and any other type of testing as specified, de-pressurizing, dewatering, drying by compressed air if applicable; pre-commissioning and providing commissioning assistance for process piping and commissioning of non-process piping, if applicable; cutting of mainline/ pipeline/ terminal piping and beveling (if required), tie-in of valve assembly, including NDT of tie-in joints; installation of piping/pipe supports; clean-up and restoration of site, preparation of as built drawings, documents and project records; transportation of surplus free issue materials to Owner's designated place(s); completing all works in all respects as per the IFC drawings, scope of work, specifications, standards and other provisions of Contract and instruction of BANDR Engineer-in-Charge. 1. This work is exclusive of all works associated with main pipeline covered at item no 01PP.02.01 above. 2. Installation of valves/ equipment etc. of size 2" NB and above will be paid separately as per items covered herein subsequently. 3. All works for piping supports will be paid separately as per items covered herein subsequently.

-

-

-

... More
Pipe OD 60.3 mm Pipe Material Grade ASTM A 106 Gr. B (CHARPY) Installation Above Ground Wall thickness (mm)/ Schedule XS

334

311288

932

... More
Pipe OD 88.9 mm Pipe Material Grade ASTM A 106 Gr. B (CHARPY) Installation Above Ground Wall thickness (mm)/ Schedule STD

101

141198

1398

... More
Pipe OD 114.3 mm Pipe Material Grade ASTM A 106 Gr. B (CHARPY) Installation Above Ground Wall thickness (mm)/ Schedule STD

488

909144

1863

... More
Pipe OD 114.3 mm Pipe Material Grade ASTM A 106 Gr. B (CHARPY) Installation Above Ground Wall thickness (mm)/ Schedule XS

41

89134

2174

... More
Pipe OD 48.3 mm Pipe Material Grade ASTM A 106 Gr. B Installation Above Ground Wall thickness (mm)/ Schedule XS

162

100602

621

... More
Pipe OD 33.4 mm Pipe Material Grade ASTM A 106 Gr. B Installation Above Ground Wall thickness (mm)/ Schedule XS

77

38885

505

... More
Pipe OD 60.3 mm Pipe Material Grade ASTM A 312 Gr. TP304 Installation Above Ground Wall thickness (mm)/ Schedule 3.91

13

20189

1553

... More
Pipe OD 21.3 mm Pipe Material Grade ASTM A 106 Gr. B Installation Above Ground Wall thickness (mm)/ Schedule S160

18

8388

466

... More
Pipe OD 26.7 mm Pipe Material Grade ASTM A 106 Gr. B Installation Above Ground Wall thickness (mm)/ Schedule S160

94

47470

505

... More
Pipe OD 168.3 mm Pipe Material Grade ASTM A 106 Gr. B (CHARPY) Installation Above Ground Wall thickness (mm)/ Schedule STD

30

83850

2795

... More
Pipe OD 48.3 mm Pipe Material Grade ASTM A 312 Gr. TP304 Installation Above Ground Wall thickness (mm)/ Schedule S40

9

10485

1165

... More
Pipe OD 273 mm Pipe Material Grade API 5L Gr. B PSL 2 Installation Above Ground Wall thickness (mm)/ Schedule 6.35

61

284138

4658

... More
Pipe OD 406.4 mm Pipe Material Grade API 5L Gr. B PSL 2 Installation Above Ground Wall thickness (mm)/ Schedule 6.35

4

29808

7452

... More
Pipe OD 660 mm Pipe Material Grade API 5L Gr. X-52 PSL 2 Installation Above Ground Wall thickness 17.5 mm

286

2943798

10293

... More
Pipe OD 660 mm Pipe Material Grade API 5L Gr. X-52 PSL 2 Installation Above Ground Wall thickness 23.8 mm

93

1084938

11666

... More
Pipe OD 323.9 mm Pipe Material Grade API 5L Gr. X-52 PSL 2 Installation Above Ground Wall thickness 14.3 mm

4

19004

4751

... More
Pipe OD 660 mm Pipe Material Grade API 5L Gr. X-70 PSL 2 Installation Above Ground Wall thickness 12.8 mm

54

543510

10065

... More
Pipe OD 323.9 mm Pipe Material Grade API 5L Gr. B PSL 2 Installation Above Ground Wall thickness 15.9 mm

27

129681

4803

... More
Pipe OD 406.4 mm Pipe Material Grade API 5L Gr. X-52 PSL 2 Installation Above Ground Wall thickness 15.9 mm

18

115272

6404

... More
Pipe OD 273 mm Pipe Material Grade API 5L Gr. X-52 PSL 2 Installation Above Ground Wall thickness 12.7 mm

22

88066

4003

... More
Pipe OD 406.4 mm Pipe Material Grade API 5L Gr. B PSL 2 Installation Above Ground Wall thickness 6.35 mm

13

83252

6404

... More
Pipe OD 508 mm Pipe Material Grade API 5L Gr. B PSL 2 Installation Above Ground Wall thickness 6.35 mm

9

72054

8006

... More
Pipe OD 610 mm Pipe Material Grade API 5L Gr. B PSL 2 Installation Above Ground Wall thickness 7.92 mm

27

250830

9290

... More
Pipe OD 660 mm Pipe Material Grade API 5L Gr. B PSL 2 Installation Above Ground Wall thickness 7.92 mm

36

362340

10065

... More
Pipe OD 219.1 mm Pipe Material Grade API 5L Gr. B PSL 2 Installation Above Ground Wall thickness 10.3 mm

12

37164

3097

... More
Pipe OD 219.1 mm Pipe Material Grade API 5L Gr. B PSL 2 Installation Above Ground Wall thickness 6.35 mm

6

18162

3027

... More
Pipe OD 273 mm Pipe Material Grade API 5L Gr. B PSL 2 Installation Above Ground Wall thickness 12.7 mm

45

180135

4003

... More
Pipe OD 323.9 mm Pipe Material Grade API 5L Gr. B PSL 2 Installation Above Ground Wall thickness 6.35 mm

22

99880

4540

... More
Pipe OD 406.4 mm Pipe Material Grade API 5L Gr. X-52 PSL 2 Installation Above Ground Wall thickness 11.1 mm

4

25616

6404

... More
Pipe OD 355.6 mm Pipe Material Grade API 5L Gr. B PSL 2 Installation Above Ground Wall thickness 15.9 mm

210

1202880

5728

... More
INSTALLATION OF VALVES/FLOW METERS/ STRAINERS/ SCRAPER TRAPS/ EQUIPMENT/ SKIDS

-

-

-

... More
Receiving and taking over of all Owner supplied/ Free Issued materials, equipment including skids from Owner's designated place(s) of issue, transportation including loading, unloading, handling from Owner's designated place(s) of issue to Contractor's owned/ hired stock yard(s)/ work site(s)/ work shop(s) including arranging all necessary intermediate storage area(s) thereof, as required; supply of all materials, equipment, consumables as defined in Contractor's scope of supply and its transportation to the work site(s);installation of valves, flow meters, strainers, scraper traps including QOEC, equipment, skids etc., fixing of gaskets, stud bolts, nuts of all sizes including torque tightening as applicable, leveling, aligning, installation and assembly of accessories, including accessories for actuators, making electrical/ pneumatic connections for such actuators, if any, by bolting/threading or welding of pipes at all elevations, hook up works with others facilities as necessary as per P&ID, testing, completing all works in all respects as per drawings, scope of work, specifications, standards, other provisions of Contract and directions of the BANDR Engineer-in-Charge. For all Instrumentation items, details/ specifications/ datasheets are covered elsewhere in the tender document.

-

-

-

... More
Installation of Scraper Launcher/Receiver as defined below: Item Type Scraper Launcher Major Barrel 762 mm Minor Barrel 660 mm Rating 600#

1

84429

84429

... More
Installation of Scraper Launcher/Receiver as defined below: Item Type Scraper Receiver Major Barrel 813 mm Minor Barrel 660 mm Rating 600#

1

98109

98109

... More
Installation of Flow Meter as defined below: Item Type Mass Flow Meter Size 60.3 mm Rating 600#

1

5287

5287

... More
Installation of Flow Meter as defined below: Item Type Mass Flow Meter Size 60.3 mm Rating 150#

1

4460

4460

... More
Installation of Flow Meter as defined below: Item Type Mass Flow Meter Size 323.9 mm Rating 600#

2

43680

21840

... More
Installation of Strainer as defined below: Type T-Type Ends Butt Welded Size 355.6 mm Rating 600#

2

57444

28722

... More
Installation of Strainer as defined below: Type T-Type Ends Butt Welded Size 273 mm Rating 150#

1

20371

20371

... More
Installation of Skid as below: Type of Skid Any Other type

0.25

4851

19407

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 219.1 mm Rating 600#

1

16606

16606

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 88.9 mm Rating 150#

9

13581

1509

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 88.9 mm Rating 600#

15

39480

2632

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 114.3 mm Rating 600#

7

26439

3777

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 60.3 mm Rating 150#

37

50283

1359

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Butt Welded Operation Manual Size 60.3 mm Rating 600#

3

6462

2154

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Butt Welded Operation Manual Size 114.3 mm Rating 600#

2

7554

3777

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 273 mm Rating 900#

1

18996

18996

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 508 mm Rating 150#

1

44557

44557

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 610 mm Rating 150#

1

48686

48686

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 60.3 mm Rating 600#

24

51696

2154

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Butt Welded Operation Manual Size 660 mm Rating 600#

1

48686

48686

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Butt Welded Operation Actuated (MOV) Size 660 mm Rating 600#

4

198516

49629

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Buried End Type Butt Welded Operation Actuated (MOV) Size 660 mm Rating 600#

2

99258

49629

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 273 mm Rating 600#

2

37270

18635

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 60.3 mm Rating 900#

1

2793

2793

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 114.3 mm Rating 150#

10

28080

2808

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 60.3 mm Rating 300#

1

1624

1624

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 660 mm Rating 600#

2

97372

48686

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 660 mm Rating 900#

2

138524

69262

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Actuated (MOV) Size 660 mm Rating 900#

1

69262

69262

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Butt Welded Operation Actuated (MOV) Size 660 mm Rating 900#

1

69262

69262

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Actuated (MOV) Size 355.6 mm Rating 600#

10

244700

24470

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Actuated (MOV) Size 323.9 mm Rating 600#

1

18384

18384

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Actuated (MOV) Size 323.9 mm Rating 900#

3

77511

25837

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 355.6 mm Rating 600#

1

24470

24470

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 168.3 mm Rating 150#

3

14541

4847

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 273 mm Rating 150#

3

28137

9379

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 323.9 mm Rating 900#

3

77511

25837

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Actuated (MOV) Size 406.4 mm Rating 900#

1

38998

38998

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Actuated (MOV) Size 660 mm Rating 600#

3

151710

50570

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Actuated (MOV) Size 323.9 mm Rating 150#

1

11263

11263

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Manual Size 660 mm Rating 150#

1

30019

30019

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Actuated (MOV) Size 660 mm Rating 150#

3

90057

30019

... More
Installation of Valve (Ball/ Plug/ Gate/ Globe/ Check/ PCV/FCV/SDV/Butterfly) as below: Installation Above Ground End Type Flanged Operation Actuated (MOV) Size 406.4 mm Rating 600#

1

38998

38998

... More
RADIOGRAPHY WORKS

-

-

-

... More
Performance of radiographic inspection of piping of all types, sizes, thickness including providing or hiring of all necessary equipment, supply of all consumables including radiographic films and whatever else even though not expressly mentioned but required to perform the work as per specification and instructions of BANDR Engineer-in-Charge. All works shall be done as per details below:

-

-

-

... More
Pipe OD 610 mm

3

11178

3726

... More
Pipe OD 114.3 mm

90

55890

621

... More
Pipe OD 168.3 mm

3

2796

932

... More
Pipe OD 219.1 mm

3

3726

1242

... More
Pipe OD 273 mm

15

23295

1553

... More
Pipe OD 88.9 mm

22

10252

466

... More
Pipe OD 60.3 mm

60

27960

466

... More
Pipe OD 323.9 mm

11

20493

1863

... More
Pipe OD 355.6 mm

37

80438

2174

... More
Pipe OD 508 mm

3

9315

3105

... More
Pipe OD 48.3 mm

26

12116

466

... More
Pipe OD 660 mm

63

254331

4037

... More
Pipe OD 26.7 mm

15

6990

466

... More
Pipe OD 33.4 mm

15

6990

466

... More
Pipe OD 406.4 mm

7

19565

2795

... More
Pipe OD 21.3 mm

3

1398

466

... More
PAINTING WORKS

-

-

-

... More
Supply of paints, solvents and primers, preparation of surfaces and application of primer and finish paints suitable for highly corrosive/corrosive/ normal corrosive painting environment for above ground piping including valves & fittings as defined in contract document and as per standard specification for Surface preparation and protective coating, identification, lettering/ numbering, colour coding etc. as specified including rub down and touch up of shop primer or scrapping of shop primer wherever required and providing of scaffolding for all heights, labour, materials, tools and tackles, consumables, supervision etc. to complete the work in all respect as per Standard/ Job Specification, Drawings, Standards and instruction of BANDR Engineer-in-Charge. All works shall be done as per details below.Supply of thinner shall also be in contractor's scope.

-

-

-

... More
Pipe OD 21.3 mm Painting Environment Industrial

9

657

73

... More
Pipe OD 610 mm Painting Environment Industrial

28

32144

1148

... More
Pipe OD 88.9 mm Painting Environment Industrial

94

28012

298

... More
Pipe OD 219.1 mm Painting Environment Industrial

21

8673

413

... More
Pipe OD 273 mm Painting Environment Industrial

135

69525

515

... More
Pipe OD 168.3 mm Painting Environment Industrial

30

9510

317

... More
Pipe OD 33.4 mm Painting Environment Industrial

114

10032

88

... More
Pipe OD 48.3 mm Painting Environment Industrial

171

27360

160

... More
Pipe OD 60.3 mm Painting Environment Industrial

324

65448

202

... More
Pipe OD 114.3 mm Painting Environment Industrial

480

148320

309

... More
Pipe OD 323.9 mm Painting Environment Industrial

54

32832

608

... More
Pipe OD 355.6 mm Painting Environment Industrial

210

140700

670

... More
Pipe OD 508 mm Painting Environment Industrial

9

8613

957

... More
Pipe OD 26.7 mm Painting Environment Industrial

81

6885

85

... More
Pipe OD 406.4 mm Painting Environment Industrial

21

16086

766

... More
Pipe OD 660 mm Painting Environment Industrial

435

541140

1244

... More
PIPE SUPPORT WORKS

-

-

-

... More
Supply of all materials required for fabrication of pipe supports & special supports including supply of bolts, nuts, washers, U Clamps, Wooden Blocks, Teflon Pads, SS Plates (as required) etc. as mentioned in the drawing/ standards and as defined in scope of work document, fabrication and erection of pipe/ equipment supports (for all sizes/ thickness) including shoes, pipes, cradles, turn buckles, T-posts for all types of guides, anchors, special supports for cold/hot insulated pipes etc. if applicable, all necessary equipment, consumables, labour etc. for completing all works, supply and application of paints and primers suitable for painting environment as defined in contract document and as per standard specification for Surface preparation and protective coating and completing the work as per drawings, scope of work, specifications, standards, other provisions of Contract and instruction of BANDR Engineer-in-Charge.

-

-

-

... More
CS Structural Steel

0.5

45964

91929

... More
Stainless Steel

0.05

18630

372600

... More
HYDRAULIC BOLT TENSIONING

-

-

-

... More
Carrying out tensioning of bolted joints on all types of piping as per specification (EIL Specification no. 6-76-0002 or any other job specification, as included in tender document) including supply of all materials, recording devices, instruments etc.; providing all specialized equipment, skilled/ unskilled man power, specialist, supervisory staff and completing the work in all respects as per scope of work, specifications, provisions of Contract document and instructions of BANDR Engineer-in-Charge for following details

-

-

-

... More
Joint Size 273 mm Rating 600#

6

28164

4694

... More
Joint Size 219.1 mm Rating 600#

5

18780

3756

... More
Joint Size 660 mm Rating 600#

19

230014

12106

... More
Joint Size 660 mm Rating 900#

8

125896

15737

... More
Joint Size 323.9 mm Rating 600#

8

48560

6070

... More
Joint Size 355.6 mm Rating 600#

38

249774

6573

... More
Joint Size 114.3 mm Rating 900#

1

2998

2998

... More
Joint Size 168.3 mm Rating 900#

1

4197

4197

... More
Joint Size 219.1 mm Rating 900#

1

5258

5258

... More
Joint Size 273 mm Rating 900#

1

6573

6573

... More
Joint Size 323.9 mm Rating 900#

20

169960

8498

... More
Joint Size 610 mm Rating 150#

4

32192

8048

... More
Joint Size 406.4 mm Rating 600#

4

30044

7511

... More
Joint Size 508 mm Rating 150#

4

26828

6707

... More
Joint Size 660 mm Rating 150#

11

95909

8719

... More
Joint Size 406.4 mm Rating 900#

4

42068

10517

... More
POSITIVE MATERIAL IDENTIFICATION

-

-

-

... More
Mobilization and demobilization of Alloy Analyzers with necessary accessories for Positive Material Identification (PMI) at site/ field, carrying out PMI of base metal, weld ments and deposited weld metal for above ground Stainless Steel (SS) Piping at all elevations as per the requirement of scope of work, Standard Specification no. 6-82-0002, instructions of Owner / Engineer-in-Charge and other provisions of Contract

1

83835

83835

... More
VIDEO FILM & PHOTOGRAPHY OF CONSTRUCTION ACTIVITIES

-

-

-

... More
Preparation of high resolution video films using drones or equivalent equipment as required (for minim 1 hr.) with audio commentary and Industrial photography covering all aspects/activities of pipeline construction annotated as required, conversion of same to video DVD/ Blue Ray/ USB Drive format, submitting three (3) sets of the same as per details in scope of work document.

0.5

209587

419175

... More
"NOTE:- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.