Urban Development And Housing Department Tender
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.
Urban Development And Housing Department Tender
Eprocure
Opening Date10 Mar 2023
Closing Date24 Mar 2023
Tender AmountRefer Documents
Costs
EMD
₹ 4,78,000Document Cost
₹ 5,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_APUDH_1159_1Bid Award Id
ViewTender No
EE/UD/JRP/SSA-01/2022-23/01Tender Authority
Urban Development And Housing Department ViewPurchaser Address
-Website
http://http://udarunachal.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dry Lean Cement Concrete Sub- baseConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.
577.5
-
-
Cement Concrete Pavement:-Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing
866.25
-
-
Cable Duct Across the Road:-Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997 and approved drawings. Triple Row for three utility services
110
-
-
Centring and shuttering including strutting proping etc. and removal of form work for:
a) Foundations and Plinth.
1163.53
-
-
Carriage of Materials
1
-
-
Sub-Head :- Boundary walls
-
-
-
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
16.8
-
-
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
2.06
-
-
Providing and laying cement concrete 1 : 3 : 6 (1 cement : 2 coarse sand : 4 stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in :
a) Foundations and plinth
1.76
-
-
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :
a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size)
0.99
-
-
Reinforcement cement concrete work in columns, pillars,post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.
a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size)
1.85
-
-
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.
a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size)
2.23
-
-
Centring and shuttering including strutting, propping etc and removal of form work for :
a) Foundation, footings, bases of columns etc. and mass concrete.
12.79
-
-
b) Column, pillars, posts and struts etc.
37.67
-
-
c) Lintels, beams, girders, bressumers and cantilevers etc
20.25
-
-
Reinforcement of RCC work including bending, binding and placing in position complete.
a) Tar/ TMT steel
1215.78
-
-
Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth.
31.5
-
-
Extra for half brick masonry in superstructure above plinth level and up to floor two level.
31.5
-
-
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.
a) Plain grill.
253.73
-
-
12 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
75.6
-
-
Colour washing such as green, blue or buff on new work (two or more coats) including a base coat of white washing with lime to give an even shade.
108
-
-
Carriage of Materials
1
-
-
Sub-Head :- M.S Gate.
-
-
-
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
9.08
-
-
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
1.45
-
-
Centring and shuttering including strutting proping etc. and removal of form work for:
a) Foundations and plinth.
7.47
-
-
b) Columns, pillars and piers.
12.72
-
-
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :
a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size)
1.96
-
-
Reinforcement cement concrete work in columns, pillars,post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.
a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size)
1.25
-
-
Providing and laying up to floor two level RCC string courses, coping bed plates, anchor blocks, plain window sills and the like including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface including centering and shuttering etc but excluding cost of reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
0.26
-
-
Reinforcement of RCC work including bending, binding and placing in position complete.
b) Cold twisted bars.
321.85
-
-
Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).
0.94
-
-
Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level.
0.51
-
-
Steel work in M.S.Gate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately).
773.89
-
-
12 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
5.91
-
-
Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade.
21.55
-
-
Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade.
34.4
-
-
Add cartage of materials by mechanical transport including loading, unloading etc complete from source to work site.
1
-
-
Sh:RCC Culvert 2mtr span)
-
-
-
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)
Marshy soil upto 3 m depth Manual means
81.48
-
-
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
9.33
-
-
a) Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications
1.04
-
-
Stone masonry work in cement mortar 1:3 in foundation complete as drawing and Technical Specification
Square Rubble Coursed rubble masonry( first sort )
29.1
-
-
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications
PCC Grade M15 Height upto 5m
9.99
-
-
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification.
41.48
-
-
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications
40
-
-
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification RCC Grade M20 Using Concrete Mixer Height upto 5m
4.68
-
-
a) Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications
1.14
-
-
Centring and shuttering including strutting, propping etc and removal of form work for :
b) Walls including attached buttresses, pilasters etc.
18
-
-
Add for carriage charges
1
-
-
Sub-Head :- Borewell
-
-
-
Provision for drilling bore hole having upto 90 mtrs. drilling depth in underground formation such as alluvial & hard rock formation for drilling diameter upto 200mm using ERW/EFW M.S. Blank/slotted Pipe upto 155mm OD with 6mm thickness all complete.
90
-
-
Geopyhsical survey Charges(minimum 3 locations) including transportation charges and labour charges etc. complete
3
-
-
External Electrification
-
-
-
C/o 33KV HT Line on 10mtr long steel tubular pole
-
-
-
STEEL TUBULAR POLES as per ISS.
10 M long of 410 SP-44
12
-
-
CONDUCTORS as per ISS
RABBIT Conductors ACSR. (6/1/35 sqmm)
3.09
-
-
STRINGING OF LINE CONDUCTOR & ACCESSORIES
Stringing of ACSR conductor as per approved sagging including installation of insulators, hardware fitting, conductors accessories, jumpering arrangement, stringing of guard wire. This shall also includes errection of PG clamp and connectors, jointing sleeves, danger plate & anticlimbing device etc. as required complete in all repsect as per TS.
ACSR / AAC Conductor 6/1/3.35 Sqmm RABBIT or equivelant conductor.( HT line) (3 wire line)
3.09
-
-
INSULATORS as per ISS
DISC (Porcelain)
Disc insulator 70 KN.
72
-
-
HARDWARE FITTING (as per ISS)
70 KN Disk Insulator (33 KV tension type hardware fitting) as required.
24
-
-
PIN (Porcelain)
Pin Insulator 33 KV with pin.
24
-
-
CROSS ARMS (MILD STEEL)
33 KV, 3 Wire, 3.05 m long cross arms made of Channel of size 125 X 50 X6 mm complete etc. as required.
4
-
-
34 KV, '' Y'' - Type cross arms made of Angle of size 50 X 50 X 6 mm in radial structure of 3 arms of 0.9 m long 120* apart complete etc. as required.
4
-
-
GI STAY SET
Galvanized stay set complete with galvanised MS anchor plate of size 300 X 300 X 5 mm, anchor rod of length 1800 mm & 18 mm alongwith stay wire, thimble, bow, guy strain insulator, nuts & bolts etc. as requried (of all size)
184
-
-
CROSS BRACING (MILD STEEL)
Angle bracing set 3.6 m long of size 65 X 65 X 6 mm complete with accessories nut / bolts etc. as reqiured.
4
-
-
SAFETY ALERT SYSTEM
Manufacturing, fabrication and supply of danger plate made of mind steel sheet of atleast 1.6 mm thick and vitreous enameled white, with letters, figures and the conventional skull and cross-bones in single red colour on the front side for -
Danger plate of size 250 mm x 200 mm of thickness 3 mm.
8
-
-
Anti climbing devices with G.I. thorwire / Barbed wire.
12
-
-
GUARD BRACKET (MILD STEEL)
33 KV, 3.5 m long Guard Bracket made of Channel of size 100 x 50 x 6 mm complete etc. as require.
4
-
-
Supply & Stringing of 8 SWG G.I. Earth wire
0.25
-
-
EARTHING SYSTEM
Earthing with 40 mm dia pipe 4.5 mtr long with GI wire for pole earthing including salt charcoal etc. as reqd.
8
-
-
PAINTINGS & FINISHING WORKS
Supply & Painting with 2 coats of red oxide paint & 2 coats of paints on pole / equipment / metal surface on full rate basis.
12
-
-
Cutting of trees, including cutting of trunks, branches and removal of stem, branches from the sutting area, stacking of servicable material at specified place not exceeding a distance of 1000 m from the cutting area along the ROW corridor of transmission lines, Sub Stations and other Power Stations.
Girth above 300 mm to 600 mm.
20
-
-
Girth above 600 mm to 1000 mm.
15
-
-
Girth above 1000 mm.
10
-
-
Cutting down of smaller trees of girth 300 mm and below including all types of vegetation, grass bushes, shrubs, saplings and remains of them for ease access for laying and stringing of conductors as well as to make foot path at tower locations or any construction site as may be required.
2000
-
-
63 KVA, 33 / 0.433 KV Distribution Sub-Station
-
-
-
Three Phase Distribution Transformers
33/0.433 KV Transformer as per ISS
3-ɸ, 100KVA, 33/0.433 KV Outdoor Type Transformer
1
-
-
Designing, Manufacturing & Supplying of 33 KV, 50 HZ Air Break Switch conforming to IS : 9920 (Pt-I to V) with rated voltage 12 KV & rated normal current shall be 400 Amps. Provided with bimetallic connector on the incomming side to accommodate ACSR of sizes 20, 30, 50 sqmm on the outgoing side
1
-
-
Designing, Manufacturing & Supplying of outdoor, drop out expulsion type of 33 KV drop out fuse suitable for insullation in 50 Hz, 33 KV distribution system conforming to IS 9385 (Pt-I to III) with rated voltage shall be 12 KV & rated current shall be 100 AMPs & also shall be provided with a suitable arrangement these on 100x50x6 mm channel cross arm.
1
-
-
Insulators as per ISS
Disc Insulator 70 KN
3
-
-
Hardware Fittings (as per ISS)
70 KN Disc Insulator (33 KV tension type hardware fittings) etc. as required
3
-
-
Designing, Manufacturing & Supplying of Lightning Arrestor of different ratings as per Specification
33 KV lines and systems
3
-
-
Steel Tubular poles as per ISS
10 Mtr long of 410 SP-44
2
-
-
GI Stay Set
Galvanized stay set complete with galvanised MS anchor plate of size 300x300x5 mm, anchor rod of length 1800 mm & dia 18 mm alongwith stay wire, thimble, bow, guy strain insulator, nuts & bolts etc. as required (of all sizes).
25
-
-
MS channel of size 100x50x4.7 mm for Air Break switch top bracket transformer mounting and Drop out fuse (8x2=16m) i/c nuts and bolts
1
-
-
LT switch Gear Systems
Designing, Manufacturing & Supply of weather proof pole mounted, LT panel Board with adequate ratings of MCCBs/RCBs/MCBs spate duly provided for mounting DT, Energy meter & service connection distribution board within the same panel
1
-
-
Energy Meters without Modems
3 Phase 4 wire LT whole current class 0.5 accuracy energy meter without CT TS/GTP 10-60 Amps.
1
-
-
Manufacturing, fabrication and supply of danger plate made of mild steel sheet of atleast 1.6 mm thik and vitreous enameled white, with letters, figures and conventional skull and cross bones in signal red colour on the front side for :-
Anti climbing devices with GI thornwire / Birbed wire
2
-
-
Designing, Manufacturing & supplying of 1.1 KV grade steel armoured Power Cable (Aluminium Conductors) of following capacities
120 sqmm x 3.5 core
30
-
-
Insulators as per ISS
Pin Insulator 33 KV with Pin
3
-
-
Painting & finishing works
Supply & painting with 2 coats of red oxide paint & 2 coats of paints on poles / equipment / metal surfaces on full rate basis.
2
-
-
Safety Alert System
Manufacturing, fabrication and supply of danger plate made of mild steel sheet of atleast 1.6 mm thick and viterous enameled white, with letters, figures and the conventional skull and cross - bones in signal red colour on the front side for -
Danger Plate of size 250 mm x 200 mm of thickness 3 mm
2
-
-
Supply & stringing of 8 SWG GI earth wire.
0.02
-
-
Copper plate earthing of transformer CBS & Batter charger including cost of copper plate size 600x600x6 mm & copper strip of size 25 x 4 mm i/c salt, charcoal etc. as required
20
-
-
3Ph, 4 Wire LT Line on 7.5mtr long steel tubular pole
-
-
-
STEEL TUBULAR POLES AS PER ISS
7.5 M Long 410 SP-9
24
-
-
CONDUCTORS as per ISS
SQUIREL Conductor ACSR,(6/1/2.11 sqmm)
5.15
-
-
STRINGING OF LINE CONDUCTOR & ACCESSORIES
Stringing of ACSR conductor as per approved sagging including installation of insulators, hardware fittings, conductor accessories,jumpering arrangement,stringing of guard wire. This shall also includes errection of PG damp and connectors,jointing sleeves,danger plate & anticlimbing device etc.as required complete in all respect as per TS.
ACSR / AAC Conductor 6/1/2.11 Sqmm SQIRREL or equivalent Conductor. (LT or HT line (3 wire line)
5.15
-
-
Supplying & Stringing of 8 SWG G.I Earth wire
1.03
-
-
Manufacturing and supplying of GI earth clamps
5
-
-
INSULAORS as per ISS
SHACKLE (Porcelain)
Shackle insulator LT with pin.
50
-
-
PIN (Porcelain)
Pin insulator LT with pin
72
-
-
CROSS ARMS (MILD STEEL)
Lt, 4 Wire cross arm made of channel of size 75 X 40 X 6 mm complete etc. as required.
24
-
-
GI STAY SET
Galvanized stay set complete with galvanized MS anchor plate of size 230 X 230 X 5 mm, anchor rod of length 1800 mm & dia 18mm alongwith stay wire, thimble, bow, guy strain insulator, nuts & bolts etc. as required (of all sizes)
115
-
-
Designning, Manufacturing & Supplying of Lighting Arrestor of different ratings as per Specification.
LT 3 Phase lines and systems.
5
-
-
SAFETY ALERT SYSTEM
Manufacturing, fabrication and supply of danger plate made of mild steel sheet of atleast 1.6mm thik and vitreous enameled white,with letters, figures and the conventional skull and cross bones in signal red colour on the front of side for :-
Danger Plate of size 250mm X 200mm with thickness 3 mm
24
-
-
Anti climbing devices with G.I thronwire / Barbed wires.
72
-
-
Manufacturing & Supply of materials for street light including the following items:-
Manufacturing & Supply of street light(LED) complete with glass cover, choke etc. as required.
24
-
-
Manufacturing & Suppling of street light bracket made of 40mm dia GI pipe
24
-
-
Manufacturing & Suppling of 1.5Sqmm single core PVC wire.
30
-
-
Manufacturing & Suppling of misc. items such as clamps, nuts & bolts.
24
-
-
EARTHING SYSTEM
Earthing with 40mm dia G.I pipe 4.5mtr. Long with GI wire for pole earthing including salt charcoal etc. as reqd.
8
-
-
PAINTING AND FINISHING WORKS
Supply & Painting with 2 coats of red oxide paint & 2 coats of paints on pole / equipment / metal surface on full rate basis.
24
-
-