Pradhan Mantri Gram Sadak Yojana Tender
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.
Pradhan Mantri Gram Sadak Yojana - PMGSY Tender
Eprocure
Opening Date2 Feb 2019
Closing Date18 Feb 2019
Tender Amount₹ 42,77,46,000
Costs
EMD
₹ 86,00,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_CEAR_73611_1Bid Award Id
ViewTender No
AR0202/032Tender Authority
Pradhan Mantri Gram Sadak Yojana ViewPurchaser Address
-Website
http://http://omms.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Sub-Head : Jungle Clearance
-
-
-
... More
Clearing and Grubbing Road Land
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.
(I) By Manual Means
(B) In area of thorny jungle
97.26
-
-
... More
Sub-Head : Earth Works
-
-
-
... More
Earthwork in Hill Road
(ii) Excavation in Hilly Areas in Soil by mechanical means
(A) Excavation in soil in Hilly Area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1 (A)Hard Soil
193437.47
-
-
... More
Earthwork in Hill Road
Excavation in Hilly Areas in Ordinary Rock by mechanical means not requiring blasting
Excavation in hilly area in ordinary rock not requiring blasting by mechanical means including cutting and trimming of slopes and disposal of cut material with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2. (A)Ordinary Rock
180048.6
-
-
... More
Excavation in Hilly Areas in Hard Rock requiring blasting
(A) Excavation in hilly areas in hard rock requiring blasting, by mechanical means, lift upto 1.5 m and disposal of excavated rock upto a lead of 20 m as per Clause 1603.2. (A) Hard Rock
129112.54
-
-
... More
Excavation in Hilly Areas in Hard Rock requiring blasting : - Extra for Every Additional Lift of 1.5 m or Part thereof
109994.95
-
-
... More
Quantum deduction for Hard rock consiering 50% of quantity is reusable
54997.47
-
-
... More
Sub-Head : Pavement (Nano Technology)
-
-
-
... More
Shoulder
-
-
-
... More
Construction of subgrade and earthen shoulders with approved material obtained from way cutting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Clause 303.1.
9348.44
-
-
... More
Waterproofing on top compacted ( as per relevant MoRD specification) sub Grade soil base, shoulders with Organosilane Nanotechnology & nano acrylic co-polymer with water (1000 ppm TDS) in the ratio of 1 kg Organosilane Nanotechnology:1 kg nano acrylic co
130878.22
-
-
... More
Loosining of the ground upto the level of 300mm below the subgrade level , watered, graded and compacted in layers to meet requirement of Table 300.1 and 300.2 for subgrade construction as per technical specification clause 303.5.2.
47094.23
-
-
... More
Subgrade supporting ground Waterproofing on top compacted ( as per relevant MoRD specification) sub Grade soil base, shoulders with Organosilane Nanotechnology & nano acrylic co-polymer with water (1000 ppm TDS) in the ratio of 1 kg Organosilane Nanotech
156980.76
-
-
... More
Water Resistant Cement Stabilized Base
-
-
-
... More
Stabilized Sub base / Base: Providing, laying, Spreading and compacting in-situ/borrow area soil /Murrum of CBR 5% mixed with / without 30% muruum / GSB Grade 1 / crushed aggregate/Aggregate- Crushable type such as moorum or Gravel for Grading I.
20532.22
-
-
... More
Prime Coat
-
-
-
... More
Preparing and applying of water soluble organo silane nanotechnology (for bitumen emulsion application, IRC approved) with cationic bitumen emulsion CSS1 and water (1000 ppm TDS) in the ratio of 1 kg organo silane : 100 kg cationic bitumen emulsion CSS1
93757.8
-
-
... More
20 mm thick Open Graded Premix Carpet using Bitumen Emulsion as per Technical Specification Clause 508.2
-
-
-
... More
Open-Graded Premix Surfacing (Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates using cationic bitumen emulsion MS grade mixed with 0.5% organosilane nanotechnology by weight of emu
93757.8
-
-
... More
Seal Coat :-
-
-
-
... More
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type-A seal coat using Crushed stone chipping of 6.7 mm size 100 per cent passing 11.2 mm sieve and retained on 2.36 mm sieve
93757.8
-
-
... More
Sub-Head : Cross Drainage Works
-
-
-
... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of side
-
-
-
... More
(I) Upto 3 m depth. (I) Ordinary Soil
9268.15
-
-
... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
P.C.C grade M 10
Nominal mix 1:3:6
1600.52
-
-
... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204
-
-
-
... More
a) Coursed Rubble msonary (first sort)In 1:4 cement mortar (Foundation )
5183.31
-
-
... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204
-
-
-
... More
a) Coursed rubble masonry (2nd sort)In cement-lime-mortar (1:0.5:4.5) (Substructure )
3032.2
-
-
... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8
-
-
-
... More
A. Granular material
1572.87
-
-
... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing
3570
-
-
... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
-
-
-
... More
RCC Grade M20 using concrete mixture For nominal mix 1:2:4 (nominal mix)
172.03
-
-
... More
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11
175.84
-
-
... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
-
-
-
... More
For Height Upto 5.0 Mtrs R.C.C. Grade M20
79.33
-
-
... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
-
-
-
... More
RCC Grade M25 using concrete Mixture R.C.C M 25
599.96
-
-
... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
-
-
-
... More
R.C.C Grade M20 Nominal Mix 1:2:4 End Pillars
34.56
-
-
... More
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
61.46
-
-
... More
Sub-Head : Minor Bridges
-
-
-
... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of side
-
-
-
... More
Ordinary Soil
-
-
-
... More
a) Below Water level
330.54
-
-
... More
b) Marshy soil
223.67
-
-
... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
-
-
-
... More
PCC Grade M10 Nominal Mix 1:3:6
19.2
-
-
... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
-
-
-
... More
PCC Grade M15 Nominal Mix 1:2.5:5 Hand Mixing
221.24
-
-
... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
-
-
-
... More
RCC Grade M20
8.21
-
-
... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing
70
-
-
... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8
-
-
-
... More
(i) Granular material
58.14
-
-
... More
Supplying, fitting, and placing HYSD bar reinforcement in substructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
4.59
-
-
... More
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC:83 (Part-II) Section IX complete, including all accessories as per drawings and technical specification Clause 1207.1
90000
-
-
... More
RETURN WALL
-
-
-
... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of side
-
-
-
... More
Ordinary Soil
-
-
-
... More
a) Below Water level
140.16
-
-
... More
b) Marshy soil
99.98
-
-
... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
-
-
-
... More
PCC Grade M10 Nominal Mix 1:3:6
9.34
-
-
... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
-
-
-
... More
PCC Grade M15 Nominal Mix 1:2.5:5 Hand Mixing
174.95
-
-
... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing
120
-
-
... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8
-
-
-
... More
(i) Granular material
74.97
-
-
... More
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
1.23
-
-
... More
DECK SLAB
-
-
-
... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
-
-
-
... More
For Height Upto 5.0 Mtrs R.C.C. Grade M25
71.66
-
-
... More
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
4.87
-
-
... More
Drainages spouts complete as per drawing and technical specification clause 1209.
16
-
-
... More
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
5.64
-
-
... More
Providing and laying a buried expansion joint, covered with 12 mm thick, 200 mm wide galvanised weldable structrual steel plate as per IS:2062, placed symmetrical to centre line of the joint, resting freely over the top surface of the deck concrete, welding of 8 mm dia, 100 mm long galvanised nails spaced 300 mm c/c along the centre line of the plate, as per technical specifications Clauses 1207.2.3
15
-
-
... More
Providing and fillling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight.
15
-
-
... More
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as pe
44
-
-
... More
Construction of RCC guide posts of 250 mm dia M20 grade cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC posts not to exceed 1 in 500 as per drawing and Technical Specification Clause 1608.2
308
-
-
... More
Sub-Head : Protective Works
-
-
-
... More
Excavation in soil in Hilly Area by manual means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per drawing and Technical Specification Clause 1603.1
2857.47
-
-
... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203.
289.27
-
-
... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203. (A) Cement mortar1:3 (1cement :3 sand)
3340.45
-
-
... More
Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 600, 1202 & 1203 ..Brick masonry in 1:3 cement mortar
1676.03
-
-
... More
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11
1327.02
-
-
... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing
634
-
-
... More
Sub-Head : Side Drain
-
-
-
... More
Earthwork in excavation for structures as per drawing and technical specification Clause 305.
506.25
-
-
... More
Plain cement concrete M10 grade
40.5
-
-
... More
Stone Masonary in Cement Morter.
182.25
-
-
... More
Sub-Head : Road & Traffic Signs
-
-
-
... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be we
5
-
-
... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron p
60
-
-
... More
Provision and fixing of traffic signs for limited period at suitable locations in construction zone comprising of warning zone, approach transition zone, working zone and terminal transition zone with a minimum distance of 2-3 m from the edge of the carri
75
-
-
... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
-
-
-
... More
a]5th Kilometre Stone (precast)
8
-
-
... More
b] Ordinary 1 Km. stone (Size - 66 x 35 x 25 cm)
35
-
-
... More
c] 200 Mtr stone (precast)
175
-
-
... More
Provision and fixing of traffic signs for limited period at suitable locations in construction zone comprising of warning zone, approach transition zone, working zone and terminal transition zone with a minimum distance of 2-3 m from the edge of the carriageway. The bottom edge of the lowest sign plate to be not less than 2 m above the road level, fixed on 600 mm x 600 mm x 6 mm angle iron post, founded and installed as per approved design and drawings, removed and disposed of after completion of construction work, all as per IRC:SP:55-2001.
-
-
-
... More
Traffic sign ahead
4
-
-
... More
Men at work
4
-
-
... More
Loose chippings
3
-
-
... More
Do not enter
4
-
-
... More
Road closed
4
-
-
... More
Stop
4
-
-
... More
Slow
4
-
-
... More
Speed limit
4
-
-
... More
Routine Maintenance
-
-
-
... More
First Year
-
-
-
... More
Second Year
-
-
-
... More
Third Year
-
-
-
... More
Fouth Year
-
-
-
... More
Fifth Year
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements