Military Engineer Services Tender
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.
Military Engineer Services - MES Tender
Eprocure
Opening Date16 Jul 2024
Closing DateCancelled
Tender Amount₹ 36,00,000
Costs
EMD
₹ 72,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_666263_1Tender No
8635/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR AND MAINT OF SECURITY/ PERIMETER LIGHT/ HIGH MAST LIGHTS/ SOLAR LIGHTS/ GARDEN LIGHTS AND CONNECTED ITEMS AND REPAIR/ MAINT TO LT EXTERNAL ELECTRIFICATIONS AT BORARUPAK I AND II MIL STN UNDER GE 872 EWS
BOQ Items
... More
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
75.8
-
-
... More
M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed.
(Note: Thickness after punning down shall be measured for payment)
63
-
-
... More
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm complete all as specified and directed.
5170
-
-
... More
Dismantling of unserviceable broken LT steel pole/Strut any size including demolition of foundation as required and making good disturbed surface complete all as directed. (Note : Earth work wherever invloved shall be measured and paid separately)
16
-
-
... More
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside serviceable materials for re-use with in 50m and removing unserviceable materials from site of work incluidng demolition of PCC foundation and taking out base plate etc complete all as directed by the Engr-in-Charge
8
-
-
... More
Dismantling existing unserviceable GI earth wire, cradles of any type from service feeder or distributor span complete all as specified and directed.
0.75
-
-
... More
Dismantling/taking down old aluminium steel reinforced (ACSR) conductor of any size from LT overhead line including all jumper etc and keeping serviceable materials in safe custody for reuse in the work (if any) complete all as specified and directed.
9
-
-
... More
Dismantling LT Stay assembly, of any size and unserviceable materials removing from the Site(s), complete all as specified and directed.
(Note: (a) Unserviceable Stay assembly shall be taken off/dismantled at Ground Level and making good disturbed ground surface.
(b) Earthwork for demolition of cement concrete shall be measured and paid separately under relevant Items of this Schedule.)
15
-
-
... More
Dismantling of insulators of any type from LT poles of any size and type and setting aside complete all as specified and directed.
60
-
-
... More
M & L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including one coat of aluminium paint over a coat of red oxide zinc chrome primer and providing 03 Nos band/strap with black/yellow colour paint 300mm apart from the plinth block, numbering of pole painting embedded portion of pole with one coat of black bitumenous paint complete all as specified and directed. (Note : Excavation and Earth work shall be measured and paid separately)
16
-
-
... More
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
0.4
-
-
... More
M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
14.5
-
-
... More
M & L for plain cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed.
2.2
-
-
... More
M & L for Cross arms bracing supports clamps and back plates fabricated from structural steel sections including nut bolt washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and including one primer coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
8
-
-
... More
M & L for pin type porcelain vitreous white/brown insulator including one galvanised mild steel spindle two galvanised iron nut 100 mm height 65 mm dia suitable for 1100 volts grade complete all as specified and directed.
60
-
-
... More
M & L for galvanised steel continuous earth wire 3.15mm or 4 mm dia suitable for LT over head line complete all as specified and directed.
0.4
-
-
... More
M & L for galvanised steel earth wire 4 mm dia (hexagonal/rectangular) used for craddle guarding suitable for LT over head line complete all as specified and directed.
0.35
-
-
... More
S & F aluminium conductor steel reinforced (ACSR) conductor including binding, straining in /LT over head line including all jumper connection and binding on insulator with new wire complete all as specified and directed.
9
-
-
... More
Re-straining and tightening of existing serviceable ACSR conductor of any size without taking down including all arangement and including binding wire 2 mm dia and colour sleeve Jumpers complete all as specified and directed.
4
-
-
... More
S & F PVC/fibre separator for LT over head line 1100 volts conductor 3/4 wire system for horizontal two Nos, in span including taking down old separator complete all as specified and as directed .
80
-
-
... More
M & L for Stay assembly complete with all accessories as shown in electrical plate No 1 of MES Schedule Part I dia of stay rod 16mm with and including 7 / 3.15 mm galvanised stay strand complete all as specified and directed.
(Note : Loop insulator, excavation & earthwork and cement concrete measured and paid separately under relevant items of this Schedule.)
15
-
-
... More
M & L for loop type insulator, vitreous porcelain, white, brown or green of overall dimension 65 x 90 mm, clearance of hole 25.5 mm etc complete all as specified and directed.
5
-
-
... More
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
200
-
-
... More
All as per Serial item No. 26 above but for 10 Sqmm 4 core cable complete ditto
100
-
-
... More
All as per Serial item No. 26 above but for 16 Sqmm 4 core cable complete ditto
150
-
-
... More
All as per Serial item No. 26 above but for 25 Sqmm 3.5 core cable complete ditto
150
-
-
... More
All as per Serial item No. 26 above but for 35 Sqmm 3.5 core cable complete ditto
100
-
-
... More
All as per Serial item No. 26 above but for 50 Sqmm 3.5 core cable complete ditto
100
-
-
... More
All as per Serial item No. 26 above but for 70 Sqmm 3.5 core cable complete ditto
100
-
-
... More
S & F in repair LED 50 Watt, Energy saving, environmental friendly, long life, one design for aesthetic consistancy in multi purpose application with SMD LEDs as light source with driver included, suitable for highlighting architectural features or Area lighting. Also suitable to rough services/installations. and with lamp and all accessories including mounting clamps, bolts, nuts and washers and copper conductor cable of suitable size to fittings of suitable length complete all as specified and as directed. (Make: Havell's Cat No. JETAQUANTOPLUSFLP50WLED757SYMLENS or equivelant of make as per list of manufacturer)
4
-
-
... More
S & F in repair 25 Watt, 230 Volts AC Post Top Lantern, outdoor type with decorative post top for 360 Degree indirect light, IP 65 protection with impact and corrosion reisitant comp[lete with driver and lamp, fixing accessories and connecting up with suitable copper conductor complete all as specified and directed. (Make: Havell's Cat No. CORALPT25WLED830SSYMTOPC or equivelant of make as per list of manufacturer)
8
-
-
... More
S & F in repair 20 Watt, 230 Volts AC Post Top Lantern, Decorative gate light made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp B22 base with driver and lamp, fixing accessories and connecting up with suitable copper conductor complete all as specified and directed. (Make: Havell's Cat No. LHFXBON1TN5Q020 or equivelant of make as per list of manufacturer)
8
-
-
... More
S & F in repairs 30 Watt, New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 with lamp and all accessories including mounting clamps, bolts, nuts and washers and connections complete all as specified and as directed. (Make: Havell's Cat No. ENDURASUNDOWNSL30WLED757PASYBOPC or equivelant of make as per list of manufacturer)
40
-
-
... More
S & F in repairs 45 Watt New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 with lamp and all accessories including mounting clamps, bolts, nuts and washers and connections complete all as specified and as directed. (Make: Havell's Cat No. ENDURASUNDOWNSL45WLED765PASYBOPC or equivelant of make as per list of manufacturer)
35
-
-
... More
S & F in repair Street light bracket arm of length not less than 1.2 m made out of GI tubing, 40 mm bore, light grade fixed to pole, etc with suitable size flat iron clamp 40x5mm of suitable length, nuts, bolts & washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
20
-
-
... More
S & F in repairs shock proof, rust proof, fire reterdant, non transperant Kiosk Pole box of size 310x210x120mm made of Negineering Plastic on piece moulded for outdoor type, heavy duty, IP-66 protection, with 4 Nos insulated aluminium bus bar of 60 Amps capacity, mounted on unbreakable insulators, MCB SP 10 Amps complete aluminium lugs of suitable size upto 50 Sqmm including 2 Nos of flat iron 40x3mm clamps with suitable MS nuts, bolts & washers etc and duly powder coated on both sides complete all as specified and directed directed. (Make : HENSEL or equivalent model of make as per list of manufacturer)
5
-
-
... More
S & F in repair PVC insulated and FRLS PVC Round Sheathed, multi-stranded Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 of size 1.0 Sqmm 3 core nominal cross sectional areacomplete all as specified and directed.
100
-
-
... More
S & F in repair 40 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors complete all as specified and directed.
10
-
-
... More
S & F in repair 50 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors complete all as specified and directed.
10
-
-
... More
M & L for boring of horizontally holes by manual method under road and dia of hole not exc 100mm without damaging the exsting road, getting out and disposal of excavated soil, etc to a distance not exc. 50 meter from the site of work complete all as directed by Engineer in charge.
5
-
-
... More
M & L for Preparation of old painted surface above the planting depth/PCC coping of steel tubular LT pole upto 11.00 metre long including MS clamps, cable protection pipe, bracket fitted with steet light fittings etc by scraping with steel wire brush and applying one coat of aluminium paint to external surface of poles, MS cross arms, MS clamp, cable protection pipe etc to give even shade including 5 Nos strips painting of 300mm high each around the pole with two different colour (black/yellow) of synthetic enamel paint and numbering of poles complete all as specified and as directed by the Engr-in-Charge.
150
-
-
... More
S & F in repairs LED Driver 24 to 45 watts as per site requirement complete all as specified and as directed.
20
-
-
... More
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab of size 350x350x50mm (reinforced with 10 mm dia TMT bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
6
-
-
... More
S & F outdoor epoxy straight through joint for LT XLPE/PVC insulated cable including all asseccories and connections for 16 Sqmm to 95 Sqmm, 3.5/4 core cable complete all as specified and directed (Excavation and earth work shall be measured and paid seperately)
1
-
-
... More
Supply, Install, Commissioning and testing LT cubical type feeder pillar Panel, CPRI approved factory made, floor mounted Indoor type, made out of 2mm thick CRCA sheet, Dust and vermin proof, weather proof , with IP-65 protection with front operared double door type and rear single door shutter with seperate hinge door with locking arragnement, totally enclosed type including PCC 1:2:4, Type B-1 foundation of suitable size, 415 Volts, 3 pahse, 4 wire, AC 50 Cycles per second having Copper bus bar insulated mounted on porcelain insulator and suitable double compression copper cable gland and internal wiring with copper conductor cable complete including taking down/dismantling existing panel board all as specified and directed comprising with the following items:
(A) Incomming:
(i) MCCB 250 Amps, 4 pole, 25 KA, 415 Volts, Adjustable thermal and magnetic release: - 01 No
(B) Outgoing:
(i) MCCB, 4 pole, 63 Amp, 25 KA, 415 Volts, Adjustable thermal and magnetic release: - 04 Nos (ii) MCB, TPN, 32 Amps - 02 Nos
(iii) Digital mulktifunction meter with 03 Nos CT of 20/5 A - 01 Set
(iv) Indicator lamp (RYB) - 01 Set of three
(v) Bus ba 4 strip, Copper of capacity 250 Amps strip TPN of suitable size - 01 Set
(Note: (i) Panel shall be of factory made and CPRI approved
(ii) External terminals with tinned copper has to be provided for trmming the incoming and outgoing cables with suitable lugs of MCB (if required)
(iii) Necessary excavation and earth work for foundation shall deemed to be included in the unit quoted rate)
3
-
-
... More
S & F in repair MCCB 415 Volt, 25 KA, 4 Pole, 160 Amps Capacity, adjustable thermal & magnetic release complete all as specified and as directed. (Make: Havell's Cat Part No. IHLANDC40160 or equivelant of make as per List of Manufacturer's)
4
-
-
... More
S & F in repair MCCB 415 Volt, 25 KA, 4 Pole, 200 Amps Capacity, adjustable thermal & magnetic release complete all as specified and as directed. (Make: Havell's Cat Part No. IHLANDC40200 or equivelant of make as per List of Manufacturer's)
4
-
-
... More
S & F in repair on load Change over switch, with SS enclosure, current rating 100 Amps, 4 pole, 415 V, 50 Hz complete all as specified and directed. (Make: Havell's Cat No. IHCNFE0100 or equivelant approved make as per list of manufacturer)
3
-
-
... More
S & F in repair on load Change over switch, with SS enclosure, current rating 63 Amps, 4 pole, 415 V, 50 Hz complete all as specified and directed. (Make: Havell's Cat No. IHCNFE0063 or equivelant approved make as per list of manufacturer)
3
-
-
... More
Material and Labour for preparation of old metal surfaces of Panel Boards over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint (1st quality) of simens grey colour by praying and marking the MES No, Panel Board No in front side complete all as specified and directed by engineer in Charge.
(Note: Adjoing areas there to properly covered befor painting. Adjoing areas, floor, walls are to cleaned free of paint spillage after painting work. If Paint spill is not cleaned to match with exsting surface a panel recovery @ Rs.200/- per location will be made from payments due to the contractor).
100
-
-
... More
M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab of size 350x350x50mm (reinforced with 10 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
13
-
-
... More
M & L Earthing complete with copper earth plate electrode 600 mm x 600mm x 3.15 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with copper earth strip of size 20x3mm by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
14
-
-
Evaluation Notes How It Works ?