Military Engineer Services Tender
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.
Military Engineer Services - MES Tender
Machinery and Tools
Eprocure
Opening Date31 Aug 2024
Closing Date21 Sep 2024
Tender Amount₹ 28,20,000
Costs
EMD
₹ 56,400Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_666864_2Bid Award Id
ViewTender No
8636/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
SPECIAL REPAIRS TO BLDG NO T-11, T-56, T-94, SPECIAL REPAIR TO BLDG NO T-43 AND SPECIAL REPAIR TO BLDG NO T-85, T-89 AT ALONG MIL STN UNDER GE 872 EWS
BOQ Items
S & F 0.63mm thick galvanised, corrugated mild steel sheeting in roof covering having zinc coating @ 275 gms/Sqm with two corrugation side lap, fixed with L type or J type or cranked hook bolts complete all as specified and directed.
40
-
-
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed.
20
-
-
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets etc complete all as specified and directed.
390
-
-
Dismantling timber scantlings 40 Sq.cm and over in section, in any position complete all as specified and directed.
2.79
-
-
M & L for second class hardwood, scantlings, clean sawn, in framed work complete all as specified and directed.
1.79
-
-
S & F aluminium Anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium T section of size 38mm x 25mm x 1.5mm thick for main runners, 25x25x1.5mm thick for cross runner and angle size 25x25x1.5mm thick alongwith wall suspended and including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to ceiling members in proper position, fixed with aluminium staple on snap grid as per manufacturer's instructions including 6 mm thick non asbestor E-board, HSPC, designer fixed to frame complete all as specified and directed by the Engr-in-Charge.
78
-
-
S & F 6 mm thick, plywood, grade BWR, type BB, fixed with screws as in wall panelling, etc complete all as specified and directed.
312
-
-
Dismantling of timber fillets, rails, posts, rafters, purlins etc under 40 sqcm in section complete all as specified and directed.
25
-
-
S & F 2nd class hard wood, Plain fillets. square, rectangular or triangular in section, wrought, secured with nails or brads, cross sectional area exc 3 Sqcm and n.exc 6 Sqcm complete all as specified and directed.
345
-
-
Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed.
24
-
-
Taking down chowkats or frames, exc 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed.
23
-
-
Taking down shutters of any description exc 1 Sqm but n. exc 2 Sqm each complete all as specified and directed.
2
-
-
S & F Well seasoned 2nd class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
0.85
-
-
M & L for plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etc including necessary form work complete all as specified and directed.
0.3
-
-
S & F mild steel bands, straps, supports or stays of rain water, ventilating pipes including bolts, hooks (stay) for large gates, hook and pintel hinges, clamps, hold fasts, wall ties, flat iron fillets for securing wire mesh, wind tie, fan hook and similar work including necessary drilling bolting or riveting etc conforming to Fe – 290 Gde E – 165 complete all as specified and as directed.
22.6
-
-
S & F Rolled sections as in framing for cladding, glazing, chowkat and the like fixed with angle cleats and connecting plates, etc Conforming to Fe-290 (Gde E165) complete all as speicfied and directed.
510
-
-
M & L for 30mm thick 2nd class hard wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkatscomplete all as specified and directed.
34.4
-
-
S & F 30 mm thick, second class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a).
45.6
-
-
S & F 30 mm thick, second class hardwood glazed and skeleton shutters open rebated and prepared to receive glass, gauge, etc, divided in to squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded complete all as specified and directed in SSR Part I Section 8 clause 8.24 (b).
22.6
-
-
S & F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
7.2
-
-
S & F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed.
7.2
-
-
S & F 100 mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and directed.
90
-
-
S & F 75 mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and directed.
120
-
-
S & F 150 mm long, Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
44
-
-
S & F 125 mm long, Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
112
-
-
S & F 125 mm size, Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
88
-
-
S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
60
-
-
S & F 300 mm Aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt complete all as specified and directed.
16
-
-
M & L for Mild steel Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden rames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165 complete all as specified and directed.
270
-
-
S & F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
37.1
-
-
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
2.5
-
-
S & F 3 mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
26.2
-
-
S & F in repairs, 300 mm long, mild steel, ordinary rat tail rod pattern springs incuding roller and roller plate complete all as specifed and directed.
12
-
-
M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed.
105
-
-
M & L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer to untreated plywood surfaces over 10 cm width or girth and complete all as specified and directed.
312
-
-
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish complete all as specified and directed
385
-
-
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed.
185
-
-
M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
125
-
-
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
10.5
-
-
M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer and over one or more coats of wall care putty to a smooth surface complete all as specified and directed.
185
-
-
M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
125
-
-
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
75
-
-
M & L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and directed.
75
-
-
Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal of debris and rubbish to a distance complete all as directed by the Engr-in-Charge
17.6
-
-
M & L for 25 mm thick, plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed.
203
-
-
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed.
145
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal of debris and rubbish complete all as specified and directed.
284
-
-
M & L for Vitrified, designed, light shade coloured (light shade), tiles, 10 mm thick, (square/rectangular) polished, area of each tiles not exc 0.36 sqm, in floors, etc and set & jointed in neat cement slurry and 3mm wide joints shall be maintained with spacers which is to be filled with epoxy grout using masking tape and the masking tape is to removed after filling the epoxy grout including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
184
-
-
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, and set & jointed in neat cement slurry and 3mm wide joints shall be maintained with spacers which is to be filled with epoxy grout using masking tape and the masking tape is to removed after filling the epoxy grout including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
85
-
-
M & L for glazed, coloured, ceramic, tiles of size (350mm x 250 mm/450mm x 350mm/300mmx450mm) x 6 to 7 mm thick, on vertical surfaces such as skirting, dados etc, and set & jointed in neat cement slurry and 3mm wide joints shall be maintained with spacers which is to be filled with epoxy grout using masking tape and the masking tape is to removed after filling the epoxy grout including 10 mm thick bedding in cement mortor 1:4 complete all as specified and directed.
15
-
-
S & F in repairs, galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
1
-
-
M & L for Preparation of old painted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint complete all as specified and directed.
610
-
-
M & L for preparing old decorated surfaces of walls including cornices, pilasters etc by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of white wash complete all as specified and directed.
90
-
-
M & L for preparing old decorated surfaces of wall, etc including cornces by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of distemper oil emulsioncomplete all as specified and directed.
105
-
-
M & L for Preparation of old painted wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
290
-
-
M & L for preparing surfaces of wood and wood based materials, new or old of any description and girth, not otherwise described and treated with two coats of creosote oil complete all as specified and directed.
10
-
-
S & F in repairs, 15mm bore, bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
1
-
-
S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed.
240
-
-
S & F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/vally gutter, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed.
24
-
-
S & F solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
4.75
-
-
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete as per specification and drawing and as directed.
1.4
-
-
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
82
-
-
Taking down unserviceable main switches, DBs, bus bars chambers, VTPN etc any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.
4
-
-
M & L for Point wiring for one light/exhaust fan/fan point/call bell controlled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socketr, shaddle etc including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed.
(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.)
62
-
-
All as per item No. 67 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
8
-
-
All as per item No. 67 above but for One 3/5 pin socket outlet 6 amps point on same board complete ditto
6
-
-
All as per item No. 67 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FR (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FR (ISI marked) as earth lead complete ditto
6
-
-
S & F switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed.
76
-
-
S & F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed.
14
-
-
S & F Switch socket combination 2 in1, 3 pin, 6 and 16Amp, flush type, universal complete all as specified and as directed.
6
-
-
S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
62
-
-
S & F Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed.
14
-
-
Taking down and dismantling the ceiling fan 1200 / 1400 mm sweep of any capacity from existing position and removing its allied spare parts for cleaning, servicing, oiling and lubricating and replacement of unserviceable parts such as bearings, bushes, etc and refixing the same fan in its original position with all the parts i.e. down rod, canopies, fan blades, spilt pins, screws, nuts and spring washers etc complete including provn flexible copper conductor cable of 24 / 0.20mm of required length with necessary connector (for blade / body) as required after rewinding complete all as specified and directed. (Note : (i) Spare parts shall be measured and paid seperately as supply only and rewinding of fan shall be measured and paid seperatly under relevant item here-in-below. (ii) The cleaning, servicing, oiling and lubricating of fans has to be carried at site itself and to be completed withing one hour unless re-winding is required. (iii) The cost of transportation from site of work to workshop and back for rewinding is deemed to be included in the unit quoted rate, (iv) Rewinding shall be carried out in contractor's workshop and fan shall be re-fixed at site withing 10 days after taking down from site. Any delay after 10 days shall be panalised @ Rs. 100.00 per day for a maximum of 10 days).
7
-
-
M & L for rewinding of Ceiling fan of any sweep after dismantling with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desired RPM including necessary insulating materials, insulating varnishing, cleaning, packing and reassembling and testing etc complete all as specified and as directed. ( Note: Also refer Note No. (iv) under Serial item No. 76 above)
7
-
-
M & L for preparation of old painted surfaces of ceiling fan of any size/sweep/make, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with filler and marking same MES No. with parmanent marker etc complete all as directed.
(Note: The ceiling fan taken down under Serial item No. 76 shall be painted and measured under this item.)
7
-
-
S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed. (Make: Havell's cat part No. DHDPSHODRW08 or equivalent make as per List of Manufacturer's)
4
-
-
S & F MCB SPN 40-63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCSNF040-63 or equivalent make as per List of Manufacturer's)
4
-
-
S & F RCBOs for earth leakage, overload & short circuit protection, 6 to 32 Amps, 2 pole, 100mA, conforming to IEC: 61009 & EMC standard EN 61543 for electrical networks with high harmonics/pulsated currents and transients with earth fault indicator & positive contact indication complete all as specified and as directed (Make : Havell's Cat part No. DHCEACSN20300 06 to 32 or equivelant of make as perList of manufacturer's)
3
-
-
S & F MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Havell's cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturer's)
16
-
-
S & F in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 350 mm x 300 mm and 50 mm deep complete all as specified and directed.
3
-
-
S & F in repairs Rigid non-metalic PVC conduit (20mmdia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed.
9
-
-
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
4
-
-
S & F Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack 20 Watt and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. LHEXBLP7PN1W020 or equivelant of make as per list of manufacturer)
32
-
-
S & F LED Bulk Head, 10 Watt, IP 65 rated, with pressure die cast aluminium housing and acrylic diffuser, CCT: WW/NW/CW, CRI 80 Ra, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LBLK02X010XC or equivelant of make as per list of manufacturer)
11
-
-
S & F Unique slimmest recess com surface panel, solution to provide variable cutout size for installation in recess mounting slim panel light fittings, 18 Watt, 6500K with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. LHEAABP7IN1W018 or equivelant of make as per list of manufacturer)
5
-
-
S & F LED Bulb, 10 Watts, B-22 Lumen ≥ 900, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI 80 Ra, IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specified and directed.
14
-
-
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
90
-
-
S & F 40 mm dia, DWC HDPE pipe, stiffness class SN8, with non smooth external annular corrugated and smooth internal surface (Double wall) for non pressure sewage & drainage application, grade conforming to IS-16098 (Part-II: 2013), in any length, with rubber ring joints, laid in trenches or in floors, etc complete all as specified and directed.
70
-
-
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
17
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
14
-
-
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements