Military Engineer Services Tender
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.
Military Engineer Services - MES Tender
Civil And Construction
Eprocure
Opening Date30 May 2022
Closing Date18 Jun 2022
Tender Amount₹ 1,08,39,341
Costs
EMD
₹ 2,06,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_MES_522090_2Bid Award Id
ViewTender No
84090E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling cross-arms of mild steel channel or angle sections etc. complete and setting aside by diconnecting all electrical connections for re-use or removing to store or for schedule of credit all as directed by Engr-in-Charge
18
-
-
Dismantling HT insulators any type, any size by diconnecting all electrical connections complete all as specified and as directed.
450
-
-
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
2592
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
1716
-
-
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
876
-
-
Supply & spreading in trenches sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
780
-
-
Supply & laying unreinforced precast concrete cable cover class LV type 1, flat shape, dimension 250 mm X 150 mm X 40 mm as per IS 5820: 1970 complete all as specified and directed.
64000
-
-
M & L for boring under road, pavement, hard standing by trenchless technology using latest boring technique and necessary machine for insertion of GI/CI/PP-R/PVC pipe of any dia/ bore/size complete all as specified and as directed. Note- Pipes shall be measured and paid separtely.
100
-
-
Supplying & laying in trenches 50 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
40
-
-
Supplying & laying in trenches 80 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
30
-
-
Supplying & laying in trenches 100 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
30
-
-
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 6 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
300
-
-
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
2900
-
-
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
1300
-
-
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
100
-
-
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
200
-
-
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 35 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
1450
-
-
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 70 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
2750
-
-
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 185 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
1460
-
-
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 300 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
900
-
-
Supply, installation, commissioning and testing LT outdoor cubical type panel board, LT (415 Volts, 50 Hz, 3-phase, 4 wire supply) floor mounted, factory assembled, double door outdoor type weather and vermin proof made out of 3.15 mm thick CRCA sheet size of min 1.00m x 0.75m x 1.50m or as per requirment to housed the item mentioned below, double panel type openable from front and rear side, rubber lining, locking arrangement, painted externally and internally with powder coated paint (first quality) complete mounted on Angle iron of min size 50x50x6 mm and housed the under mention items in independent compartment with sufficient working space for following Incoming (i) Copper bus bar 600 Amps capacity - 04 Nos (ii) MCCB 4 pole 36 KA 440 Volts, 3 phase 400 Amps - 01 Nos Outgoing (i) MCCB 4 pole 25 KA 415 Volts, 3 phase 200 Amps - 01 Nos (ii) MCCB 4 pole 25 KA 415 Volts, 3 phase 100 Amps - 01 Nos (iii) MCCB 4 pole 25 KA 415 Volts, 3 phase 63 Amps - 02 Nos (iv) MCCB 3 pole 16 KA, 415 Volts, 3 phase 32 Amps - 01 No (v) Ammeter digital type 0 to 630 Amps - 01 No (vi) Voltmeter digital type 0 to 500 Amps - 01 No (vii) LED indicator lamp Red/Yellow/Blue colour - 03 Nos (viii) CTs operated including CTs 0-400A 96 mmx96mm flush mounted with selector switch
2
-
-
Supply, installation, testing and commissioning factory made LT feeder pillar box Outdoor type suitable for 415 Volts 3 phase 4 wire system 50 Hz supply having copper bus bar 400 Amps for phases and neutral, install on porcelain / epoxy insulator. The panel shall be dust proof, vermin proof (IP54) and painted with two coats of synthetic enameled paint over a coat of red oxide primer and made out of 3.15mm CRCA sheet size of min 1.00m x 0.75m x 1.00m or as per requirment to housed the item mentioned below, self moulded type and 50x50x6 mm angle iron frame front and rear opening with double shutter and locking arrangement with 50 mm lock and including grounting of panel with necessary PCC work including taking down existing panel complete all as specified. The scope of work includes the following accessories :- Incoming :-
(i) MCCB 250 Amp with, 4 Pole, 36KA - 01 No
(ii) Volt meter 0 to 500Volts, Square flush pattern, digital type - 01 No
(iii) Amp meter suare flush pattern 0 to 20 Amps digital type - 01 No.
(iv) Indicating lamp LED type one set in incoming phases.
(v) Internal wiring with PVC insulated copper conductor multi standed cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs
(vi) Connection from MCCB to Busbar shall be of solid Aluminium conductor
(vii) MCCB shall be provided with suitable spreader of Aluminium conductor for fixing of incoming cable
Outgoing ways :- For 05 Nos outgoing
(i) MCCB 4 pole 25 KA 415 Volts, 3 phase 63 Amps - 02 nos
(ii) MCCB 3 pole 16 KA, 415 Volts, 3 phase 32 Amps - 03 Nos
5
-
-
Supply, intallation, testing and commissiong factory made LT feeder pillar box Outdoor type suitable for 415 Volts 3 phase 4 wire system 50 Hz supply having aluminium bus bar 400 Amps for phases and neutral, intall on porcelain / epoxy insulator. The panel shall be dust proof, vermin proof (IP54) and painted with two coats of syntheetic enamled paint over a coat of red oxide primer and made out of 3.15mm CRCA sheet size of min 1.00m x 0.75m x 1.00m or as per requirment to housed the item mentioned below, self moulded type and 50x50x6 mm angle iron frame front and rear opening with double shutter and locking arrangement with 50 mm lock and including grouting of panel with necessary PCC work including taking down existing panel complete all as specified. The scope of work includes the following accessories :- Incoming :-
(i) MCCB 160 Amp with, 4 pole, 25 KA - 01 No
(ii) Volt meter 0 to 500 Volts, Sqaure flush pattern, digital type - 01 No
(iii) Amp meter square flush pattern 0 to 20 Amps digital type - 01 No.
(iv) Indicating lamp LED type one set in incoming phases.
(v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs
(vi) Connection from MCCB to Busher shall be of solid Aluminium conductor
(vii) MCCB shall be provided with suitable speader of Aluminium conductor for fixing of incoming cable
Outgoing ways :- For 05 Nos outgoing
(i) MCCB 4 pole 16 KA, 415 Volts, 3 phase 32 Amps - 05 Nos
12
-
-
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
38
-
-
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
40
-
-
Supply & fixing shock proof rust proof fire retradrant non transparent Kiosks pole box of sze 310x210x120mm made of engineering plastic on piece moulding, for out door type heavy duty, with four nos of insulated Aluminium bus bar of 60 Amps capacity mounted on unbreakable insulators 6A MCB SP and complete with Aluminium lugs of suitable size upto 50 sq mm including 02 Nos 40x3 mm FI clamps nut bolts washer etc and duly painted both side with two coats of synthetic enemal paint over a coat of red oxide primer complete all as specified and directed.
70
-
-
Material & Labour for 3 core multi stranded copper conductor cable 1.0 sqmm (Nominal area) PVC insulated sheathed cable 1100 volt grade ISI marked inside LT Pole, from pole box to street light fitting complete including drilling with the pole & pole cap etc all as required and directed
700
-
-
S&F Street light bracket arm of length not less than 1.5 m made out of GI tubing, 40 mm bore, light grade fixed to ploe, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer on steel surfaces
40
-
-
M & L for steel tubular swaged pole 410 SP-31 (9.0 metre long) including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer on exposed portion and making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole including making good to match existing area complete all as specified and as directed.
10
-
-
Supply and fix in replacement of street light Digital timer comprising of incoming cable termical, MCBs, timer, contractor, outgoing termincal duly prewired and accessories housed in MS box outdoor type of capacity 40 Amps TPN, 3 pole, 230 Volts contractor rating 32 Amps TP complete all as specified and directed including installation and testng.
5
-
-
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
0.5
-
-
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
6
-
-
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
1
-
-
S & F LED street light with nominal power 45 Watt LED, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. ENDURAPEARLNEOSL45WLED757PASYTOPC of Havells or equivalent of Make mentioned under Appendix "B" including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
100
-
-