Military Engineer Services Tender

... More
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.

Military Engineer Services - MES Tender

Works
Energy, Oil and Gas
Coronavirus COVID 19
Eprocure
Opening Date11 Apr 2018
Closing Date16 May 2018
Tender Amount₹ 7,98,19,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIFICATIONS as listed in Schedule ‘A’ Part-IV.

1

-

26948.6

... More
Lumpsum price worked out by the tenderer for ROADS, PATH, HARD STANDING & GRAVEL FLOORING as listed in Schedule ‘A’ Part-V.

1

-

2910611.19

... More
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VI.

1

-

277526.08

... More
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VII.

1

-

1401195

... More
Lumpsum price worked out by the tenderer for SECURITY FENCING & GATE as listed in Schedule ‘A’ Part-VIII.

1

-

1227290.1

... More
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IX.

1

-

277207.6

... More
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIFICATION & SOLAR POWER PLANT SYSTEM as listed in Schedule ‘A’ Part-X.

1

-

3248680.18

... More
Sch 'A' Sec-XI (Miscellaneous Items)Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.

-

-

-

... More
Material and Labour for thermoplastic reflective paint for marking of 2.50 mm minimum thickness of single coat in centre line, edge line and zebra crossing road marking of 150 mm width on bituminous surfaces in white/yellow by indigenous modern propelled road marking machine including glass beads conforming to BS-6088 and MOST specifications including cleaning all dirt, scales, grease and foreigh material etc. complete all as specified.

50

-

-

... More
Supplying, Spreading and levelling of gravel in layers not exceeding 25cm thick, well ramming as in flooring of sub station complete all as specified and as directed.

30

-

-

... More
Cutting of existing DI/CI pipes of size upto 100 mm bore in position for taking out branch connection, inserting and including one number Tee of size 100 mm x 100 mm x 100 mm and connected to pipe including jointing materilas, necessary excavation in any types of soil, complete all as specified and directed.

1

-

-

... More
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top double layer) 2500 litres capacity, hoisted and fixed in position as specified in SSR Part-I complete all as specified and as directed.

2

-

-

... More
Supply and installation of self priming monoblock Pumping Sets, centrifugal, electric driven suitable for 240 volts single phase having capacity 1 HP with delivery size 25 mm, head upto 40 m, discharge upto 4 cum/hr, nominal speed 2800 rpm, including foundation with PCC (1:4:8), type-2 including fixing complete with nuts, bolts and washers as per manufacturers instructions complete all as specified and directed.

2

-

-

... More
Supply & Fixing in position 25 mm dia bronze horizontal screwed check valve, reflux with by-pass arrangement complete all as specified and as directed.

2

-

-

... More
Supply and fixing of 20 mm dia MS hose nipple complete all as specified and as directed.

15

-

-

... More
Supply and fixing fully automatic DOL Starter in SS enclosure suitable for 1 HP capacity 240 Volts centrifugal pump including installation, connection all complete alongwith voltmeter, ammeter with selector switch complete all as specified and directed.

3

-

-

... More
Supply, installation, testing and commissioning of factory made powder coated (CPRI approved) outdoor type, dust & vermin proof feeder pillar box made out of 3.15mm CRCA steel sheet of suitable size and angle iron 40 mm x 40mm x 6 mm , powder coated over one coat of red oxide primer suitably grouted in PCC-M10 using 20 mm graded stone aggregate including bus bar, internal wiring with PVC insulated single core cables of copper conductor of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type locking arrangement and slanted roof. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system. The panel board shall comprise of following items & all specified in SSR Part-I clause no 19.21 and all as shown on drawing . (A) INCOMING:- (i) MCCB 32 amps, 4 pole, breaking capacity 25 KA suitable for operation of 415 volts AC 50 HZ with earth leakage modul - 01 No, (ii) 2 strip aluminum coated copper bus bar of rating 1.5 times current carrying capacity of incoming switch gear or not less than 100 Amp whichever higher (iii) Digital voltmeter, three phase, Cl-1, 0-500V - 01 No (iv) Digital ammeter, three phase, Cl-1, 0-400V - 01 No (v) Phase indicator lamp R-Y-B, neon type (Set of Three)- 01 No (B) OUTGOING (i) MCB single pole, 25 amps, 240 volts, breaking capacity 10 KA - 06 Nos (ii) LCD multifunctional meter- 01 No (iii) Analog type time switch for street light - 01 No (iv) Power Contactor, single phase - 01 No (v) CTs 600/5 A, VA 12 - 03 Nos

1

-

-

... More
Supply and fixing of LED batten surface/ceiling mounting(suspended from ceiling) box type light fitting 20Watt with LED Lamp , drive and made of epoxy powder coated extruded aluminium channel housing with high quality polycarbonate opal diffuser cover including & high power LED’s as light source with LED fitting system lumen not less than 95% Lumen per watt and electronic driver( 80% efficiency level & THD 10%) , power factor shall be 0.95, ( 80% efficiency level & THD 10%) , power factor shall be 0.95 complete and including all other standard accessories as per manufacture instructions ,internally pre-wired including connecting up with twin core 0.50 sq. mm copper conductor flexible wire/cable complete all as specified. Make : Code No 112176 BLTRU 20W WH VIVA of BAJAJ or equivalent model of make list as given in Appdix "B".

16

-

-

... More
Supply and fixing of LED 'Baton integrated LED channel' surface/ceiling mounting(suspended from ceiling) box type light fitting 10Watt with LED Lamp , drive and made of integrated sleek extruded polycarbonate channel with white acrylic cover & high power LED’s as light source with LED fitting system lumen not less than 95% Lumen per watt and electronic driver( 80% efficiency level & THD 10%) , power factor shall be 0.95, ( 80% efficiency level & THD 10%) , power factor shall be 0.95 complete and including all other standard accessories as per manufacture instructions ,internally pre-wired including connecting up with twin core 0.50 sq. mm copper conductor flexible wire/cable complete all as specified. Make : Model No 112407 BCLSB 10 WH of BAJAJ or equivalent model of make list as given in Appdix "B".

2

-

-

... More
Supply , Fixing & testing of LED street light fitting (Building Security light) of 20 Watt with LED lamp’s & driver and made of pressure die-cast aluminum housing with epoxy power coated dark graphite grey colour finish and prismatic polycarbonate cover with individual lenses IP 65 & high power LED’s as light source with LED fitting system lumen not less than 95% Lumen per watt and electronic driver with efficiency 85% with inbuilt protection against lightning, over voltage, short circuit and surge/spike protection upto 5 KV ensuring longer life (THD 10%, PF shall be 0.95, colour temperature 5700±300 K), Life expectancy of LED's minimum 50,000 burning hrs, warranty of complete luminaries fitting shall not less than three years. The fitting shall be tested LM 79 & 80 and test certificate shall be submitted from original manufacture. The light fitting shall be fixed on pole with and including 25 mm dia( or higher size as per manufacturers recommendation) light grade GI pipe (bend to shape or as per manufacturers recommendation ) bracket 1.5 mtr long complete with MS flat iron clamp (clamps shall be 40 x 5 mm MS flat) nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primer including connection complete all as specified and directed. Make : Model No 169628 BCLST 20 W LED of BAJAJ or equivalent model of make list as given in Appdix "B".

4

-

-

... More
Supply , Fixing & testing of LED street light fitting of 60 Watt with LED lamp’s & driver and made of pressure die-cast aluminum housing, IP 65/IP 66 road way luminaries with UV stabilized polycarbonate cover or toughen glass cover & high power LED’s as light source with LED fitting system lumen not less than 95% Lumen per watt and electronic driver with efficiency 85% with inbuilt protection against lightning, over voltage, short circuit and surge/spike protection upto 5 KV ensuring longer life (THD 10%, PF shall be 0.95, colour temperature 5700±300 K), Life expectancy of LED's minimum 50,000 burning hrs, warranty of complete luminaries fitting shall not less than three years. The fitting shall be tested LM 79 & 80 and test certificate shall be submitted from original manufacture. The light fitting shall be fixed on pole with and including 25 mm dia( or higher size as per manufacturers recommendation) light grade GI pipe (bend to shape or as per manufacturers recommendation ) bracket 1.5 mtr long complete with MS flat iron clamp (clamps shall be 40 x 5 mm MS flat) nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primer including connection with two core 2.50 sqmm flexible copper conductor to control street light from ceiling rose to street light fitting complete all as specified and directed. Make : Code No 169680 BRTFG 60W LED of BAJAJ or equivalent model of make list as given in Appdix "B". Note for items No 11.10 to 11.13 : Warranty of complete LED luminaries fitting shall not less than three years and Life expectancy of LED's minimum 50,000 burning hrs.

8

-

-

... More
Supply & fixing of transparent street light junction box of size 205 mm x 255 mm x 112 mm made of high quality polycarbonate IP-66 (Dust and power jet Proof according to IEC 60529) , shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact (IK 08) totally insulated (Class II ) made of halogen and silica free recyclable material, UV resistant having high grade gasket made of polyurethane with copper bus bar 25 x 5 mm -04 strip, one no MCB SP 6 Amps with locking arrangement and 2 Nos M40 size cable gland and one M32 size gland suitable up to, 10Sqmm cable etc and fixing to the street light pole with 02 Nos, 25 x 3 mm thick MS clapms, nuts & bolt, etc. complete all as specified and directed

8

-

-

... More
Supply and fixing ceiling fan enery saving and fancy type 1400 mm(minimum) sweep three blade, 5 star BEE rating without regulator including hanging rod and necessary connecting PVC insulated Flexible cable for connection from ceiling rose to fan and connecting complete all as specified and as directed. Make: Model- ES-50 Premium of Havells or equivalent make as per Appendix 'B'.

2

-

-

... More
Design, fabrication, supply and install bus bar trunking with aluminium busbar of rating 800 Amps, 11 KV grade mounted on suitable insulators enclosed in CRCA shwwt 2 mm thick duly painted with tatally enclosed dust and vermin proof (Protected class IP-54) enamealed paint matching with existing bus bar of VCB panel as in extension of existing bus bar chamber including with connecting up complete all as specified and as directed.

1

-

-

... More
Supply and fixing of fire fighting signboards in buildings-01 No, fire extinguisher foam type, cap-6 Kg -05 Nos, CO2 type cap-4.5 Kg- 05 Nos and Sand bucket-03 Nos, water bucket-02Nos, fire bitter-01 No and fire hook-01No all as specified and directed.

1

-

-

... More
Supply and fixing of rubber mat of size 2 m x 1 m x 19 mm thick-05 Nos, discharge rods-02 Nos, 11kV Hand Gloves-01 Set, First Aid Box-01 No and Shock Treatment Chart- 01 Set and schematic line diagram of Sub-Stn with lamination sheet- 01 Set all as specified and directed.

1

-

-

... More
Design, supply, installation, testing and commissioning of Solar Power Generation Plant ground mounted, grid connected complete comprises of the following :- (a) Solar PV modules to meet cumulative rated capacity of 1 MWp at STOC. Modules will be of Poly Crystalline type with 72 cells and minimum rating of 315 Wp with positive tolerance, same make and model made in India only, with minimum 1000 mm cable length and glass thickness of PV Modules shall be minimum 3.2 mm. Module efficiency 15.8%, fill factor0.7, module will be free of PID, module connector suitable for MC4/Bizlink and jucntion box with minmimum IP 67 rating. Module NOCT will be 45±°C with temperature coefficient of power 0.4%/°C, and will be suitable for operation from -20°C to +60°C ambient temperature. Modules will be combined to make array & string of panels to maximize power output along with supply and installation of necessary accessories like fuses, array/string junction box etc., Modules will be certified for relevant dust standards (Applicable standard would be IEC 60068-2-68). Modules shall be deployed with RF id tag inside lamination as per MNRE guidelines. Guranteed electrical degradation of power generated not exceeding 20% of the minimum rated power over the 25 year period and not more than 10% after ten years period of the full rated original output. Warranty against manufacturing defect, raw material, workmanship, inspection and testing procedures shall be 5 years from the date of commissioning. Modules shall be certified as per IEC 61215-Edition -II, IEC 61646 and IEC 61730-1 & 2 and other applicable IEC/IS standards. Qty adequate to generate 1 MWp Power. Contd...

1

-

-

... More
(b) Design, supply, fabricate and fixed tilt module mounting structure hot dipped galvanised mild steel with coating not less than 85 microns and suitable to withstand wind speed upto 150 km/hour and electrolytically compatible channels, bracing purlins of any size, electromagnetic washers, nuts, bolts including cutting, drilling etc.The design should be as per IS code and suitable for the wind speed (as per Wind Zone with correction of wind load at solar panel instalation height) , sun light and climatic condition of the plant loaction. Module Ground Clearance shall be 500mm ± 100mm. The design life should be more than 25 years and minimum yield strength of steel should be minimum 345 MPA and connecting plates yield strength shall be 250 MPA. Properties of RHS will conform to IS 4923:1997. HDG Fasteners of 4.6 grade and 8.8 grade for Structure. The structure should be suitable for easy removing and refixing / replacing of PV modules of the Solar Plant. All foundation & fixing arrangement shall be in according to drawing submitted by the contractor as dedesigned by Structural Engineer duly vetted by IIT/NIT/Govt Engineering College (where Structural Engineering discipline exists at PG level) and approved by Accepting Officer before execution of wrok- Qty adequate for mounting of solar PV modules at item 1(a) above. Contd...

-

-

-

... More
(c) Supply, installation, testing and commissioning of grid tied 3 phase inverter outdoor type of with minimum IP 65 rating, with 50 KW rated capacity maximum output upto 70 KW at 50°C ambient temperature. Minimum European efficiency of the inverter shall be 98% load as per IEC-61683 standard for measuring efficiency. Maximum DC input voltage shall be 1000 V and inverter supplied shall have upto 10% additional DC input capacity. (Array to Inverter Ratio 1:1), 3 phase AC Nominal Output voltage 415 V (with ±10% range ), Frequency 50Hz (±1% range), PF at rated output capacity: 1 (with range from 0.8 lag to 0.9 lead), Total THD: 3%, Operating temperature range : - 20°C to + 60°C. All inverters should consist of associated control, protection and data logging devices and remote monitoring hardware and compatible with software used for string level monitoring.all as specified and directed maximum Quantity of Inverters- 20 Nos, No of inverters can be reduced with higher rated capacity inverters, accordingly DC/AC cables, SCBs and AC PDBs quantity/capacity to be modified). Other important features/ protection required in the inverter are as under:- (i) Automatic morning wake-up and nightly shutdown. (ii) Mains (Grid ) over-under voltage and frequency protection. (iii) Galvanic isolation and fool proof protection against ISLANDING. (iv) Included authentic tracking of the solar arrays maximum power operation voltage (MPPT). (v) Array ground fault detection. (vi) LCD and Piezoelectric keypad operator interface Menu driven. (vii) Automatic fault conditions reset for all parameter like voltage, frequency and /or black out. (viii) MOV type surge arrester on AC and DC terminals for over voltage ptotection from lightning -induced surges. Contd...

-

-

-

... More
(ix) Provision for input and output isolation. (x) Inverter shall be installed on GI stand made by the angle size 50mm x 50mm x 6mm. (x) Structure burried in ground and shall be 450mm above ground level. (xi) Grid Connectivity : Relevant CERC/RERC regulations and grid code as amended and revised from time to time shall be complied. Inverter shall adjust the voltage & frequency levels to suit the Grid. Make : MA/Delta/Huawei/ABB/Schneider/Sun Grow/ TMEIC/ Hitachi or any Tier 1 domestic manufacturer (d) Supply and installation of branch, MC4 Male/Female connectors set compatible with module connectors with min of IP66 rating and design with suitable lugs for 6 Sqmm Cable complete all as specified and directed- Adequate qty for 1 MWp Solar Power Plant as per manufacturers instruction. (e) Supply, install and laying with PVC conduits, lugs, nails, cable ties, termination etc, testing and commissioning of annealed single copper DC String cable of 1C x 6 Sqmm Solar grade, UV resistant 1.5 kV rated DC Cables with elctron beam XLPO insultaion confirming to IEC 60754-1 & IEC 60754-2, IEC 60332-1, IEC 60332-3-24, IEC 61034. Temperature range -40 to +1200 C complete all as specified and directed. Average energy loss in DC cabling shall be 1.5% from solar panel to inverter- Adequate qty for 1 MWp Solar Power Plant as per manufacturers instruction. Contd...

-

-

-

... More
(f) Supply, install and laying with conduits, lugs, nails, cable ties, termination etc., testing and commissioning of PVC insultated copper cable of 1C x 6 Sqmm for earthing conforming to IEC and IS standards- Adequate qty for 1 MWp Solar Power Plant as per manufacturers instruction. (g) Supply, install and laying with PVC conduits, lugs, nails, cable ties, termination etc, testing and commissioning of AC copper cable of 4C x 16 Sqmm from inverters to AC panels as per inverter and panel design, UV resistant 1.1 kV rated, PVC/XLPE insultaion confirming to IEC and IS standards. Temperature range -40 to +1200 C- Adequate qty for 1 MWp Solar Power Plant as per manufacturers instruction. (h) Supply and laying in duct/trenches/pipe with necessay lugs, cable termination kits, testing and installation of power cable from AC panel to main LT panel of XLPE insulated 3.5C x 300 sq mm, 1.1kV Aluminium Armoured LT cable as per relevant IS complete all as specified and directed- Adequate qty for 1 MWp Solar Power Plant as per manufacturers instruction. (j) Supply and laying in duct/trenches/pipe with necessay lugs, cable termination, testing and installation of power cable from main LT panel to transformer of XLPE insulated 1C x 300 sq mm, 1.1kV Aluminium Armoured LT cable as per relevant IS complete all as specified and directed- Adequate qty for 1 MWp Solar Power Plant as per manufacturers instruction. Contd...

-

-

-

... More
(k) Supply, install, testing and commissioning of Data Monitering system communication cable RS 485 (screen twisted) complete all as specified and as directed. (l) Supply, install, testing and commissioning of Inverter communication Shielded CAT6 cables complete all as specified and directed-Adequate qty for 1 MWp Solar Power Plant as per manufacturers instruction. (m) Supply, installation, testing and comissioning of weather and vermin proof indoor type LT Panel factory made, front & back openable, double door type, CPRI approved fabricated out of 2 mm thick CRCA (Cold Rolled Closed Annealed Cell) sheet compartmentalized design including mild steel channel frame of ISMC 75 at the base of panel only for grouting purpose, and grouted with PCC using 20 mm graded stone aggregate, duly epoxy powder coated, complete with heat shrink insulated aluminium bus bar of 1200 Amps rating 4 Nos, including all connections with aluminium strips. Pillar box shall be provided with danger notice plate with skull & bone sign, PVC gasket and sealed, making all incoming and out going electrical cable connections with new lugs, glands to be provided at cable entries, including angle iron support 50x50x6 mm with 50 CM height from ground level at the base of panel complete all as specified and as directed (Qty-05 Nos). Each panel shall be comprising of following accessories:- Contd...

-

-

-

... More
INCOMING: - (a) MCCB, TPN 415 Volts, 50Hz, 125 Amps, 16 KA, thermal magnetic release, Ics =100% Icu, front face isolataion with positive break indication with double break contacts with spreader and phase barrier - 04 Each (b) Volt meter 0-500 V digital type with selector switches - 01 Nos. (c) Multi function digital energy meter with RS 485 communication port with CTs . (d) Phase Indicator lamp assy RYB - 01 Set. (e) CT Coils of suitable ratio - 01 Set. OUTGOING : - (a) LT Air Circuit Breaker with new ACB 630 Amps, 50KA, 4 pole, 415 volts, 50 Hz for rated current at ambient temperature 50 degree C and confirming to IS-13947 (Part 3, 1993) and IEC : 60947 (Part 1 & 2) and other technical features as per SSR Part I para 19.100.13 with manual operated draw out type Icu=Ics (1 sec) with microprocessor release 6L (over load, short circuit, instanteneous and earth fault protection), pre trip alarm and individual fault indication LED with fully rated neutral with inbuilt protection. The over load release shall be adjustable type and ACB shall have zone selective interloacking fault signalling contact. The ACB cradle should have the provision to keep the racking handle. The ACB should be with terminal adopter both incoming and outgoing - 01 No Contd....

-

-

-

... More
(n) Supply, installation, testing and comissioning of weather and vermin proof indoor type LT Panel factory made, front & back openable double door type, CPRI approved, fabricated out of 2 mm thick CRCA sheet compartmentalized design including mild steel channel frame of ISMC 75 at the base of panel only for grouted wiht PCC using 20 mm graded stone aggregate, duly epoxy powder coated, complete with heat shrink insulated aluminium bus bar of 2500 Amps rating 4 Nos, including all connections with aluminium strips, Pillar box shall be provided with danger notice plate with skull & bone sign, PVC gasketed and sealed, making all incoming and out going electrical cable connecetions with new lugs, glands to be provided at cable entries, including angle iron support 50x50x6 mm with 50 CM height from ground level at the base of panel complete all as specified and as directed. The panel shall be comprising of following accessories:- 01 No INCOMING:- (a) MCCB, TPN 415 Volts, 50Hz,630 Amps, 50 kA, thermal magnetic release, Ics =100% Icu, front face isolataion with positive break indication with double break contacts with spreader and phase barrier - 05 Each (b) Volt meter 0-500 V digital type with selector switches - 01 Nos. (c) Multi function digital energy meter with RS 485 communication port with CTs (d) Phase Indicator lamp assy RYB - 01 Set. (e) CT Coils of suitable ratio-01 Set. OUTGOING:- (a) LT Air Circuit Breaker with ACB 2500Amps, 50 kA, 4 pole, 415 volts, 50 Hz for rated current at ambient temperature 50°C and conforming to IS-13947 (Part 3, 1993) and IEC- 01 No Contd...

-

-

-

... More
(o) Supply, installation, testing and comissioning of copper wound inverter duty step-up transformer of 1.2 MVA, 0.415/11 kV with standard fittings and accessories such as conservator, protection relays, instrumentation as per applicable IEC/IS standards. No Load Losses shall be 0.15% of rated capacity and Full Load Losses 1.1% of rated capacity. LV rated voltage: as per inverter output, HV voltage range: 11 kV±10% with 2.5% steps of OLTC tap changer . Cooling: ONAN, Imepedence: As per inverter manufacturer recommendatio/IS standard. Installation: Outdoor, Temperature Rise above ambient of 50 deg C: for Oil- 50 Deg for Winding:- 55 deg C, Fault Level at terminals: MV Side (25kA for 2 sec), LV Side (35kA for 2 sec), Creepage at MV Side: 25mm/ kV. Necessary civil foundation and structure with fencing to be provided. 01 No Note :- (i) First fill of oil as per manufacturer instructions shall deemed to be included in the unit rate quoted by contractor. (ii) Plinth for transformer including stone metal aggregate around transformer plinth with and including slant slot for accomodating 100 mm dia pipe on both LT & HT side with clamping arrangement of size and specifications as per manufacturer instructions, shown on drawings and as directed by the Engineer-in-charge complete shall deemed to be included in the unit rate quoted by contractor. Contd...

-

-

-

... More
(o)(o) Supply, installation, testing and commissioning for the weather monitering system shall be having all hardware / parameters compatible with SCADA system and capable of monitering data from various weather sensors having analog, digital & counter output consist the following (i) Wind direction sensor output 4-20 MPa, range 0 to 360 degree and accuracy 1% full scale. (ii) Wind speed sensor range 0-100 MPH (iii) Solar radiation sensor output 4-20Ma, range 0-1500 W/sqm (iv) Humidity sensor range 0-100% RH (v) Temperature sensor range -50 degree C to 50 degree C accuracy + 2 degree F or + 1 degree F. (vi) Barometer pressure sensor (vii) The output from WMS is on MODBUS TCP/485 protocol for communication and syncronising with SCADA system. Contd...

-

-

-

... More
(p) Supply, installation, testing and commissioning of on grid Data Acquistition / Plant monitoring system (SCADA) suitable for 3 Phase, 415V, 50Hz, AC power string inverter with all protection & controlling as per specifications complete etc as per requirement with an overall efficiency of not less than 98% (with inbuilt or external data logging device & on line portal log-in ID & password) & one PC with intel i5 processor, 2TB HDD, 4GB RAM, 19'' LED monitor, preloaded with Window10 & MS Office, one all-in-one printer suitable for A-4 size papers (black and white). The following parameters (i) to (xvii) should be accessible via operating interface display in real time separately for solar power plant. (i) AC Voltage (ii) AC Out put current (iii) Output power (iv) Power factor (v) DC Input Voltage (vi) DC Input Current (vii) Time Active (viii) Time Disabled (ix) Time Idle (x) Power produced (xi) Protective function limits (viz-AC Over Voltage, AC Under voltage, Over frequency) (xii) All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) should be made available for energy auditing thourgh the internal microprocessor & should be read on the digital front panel. Contd...

-

-

-

... More
(xiii) PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current and Energy gererated by the PV system provided. Energy meter along wiht CT/PT should be of 0.5 accuracy class (xiv) Computerized DC String/ Array monitoring and AC output monitoring shall be provided as part of the inverter and/or monitoring shall be provided as part of the inverter and /or string/array combiner box or separately. Make : Solar Pulse, Phoenix / Trinity Touch / Gamesa/ Inverter OEM's make. (xv) All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) should be made available for energy auditing thourgh the internal microprocessor & should be read on the digital front panel. (xvi) PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current and Energy gererated by the PV system provided. Energy meter along wiht CT/PT should be of 0.5 accuracy class. (xvii) Computerized DC String/ Array monitoring and AC output monitoring shall be provided as part of the inverter and/or monitoring shall be provided as part of the inverter and /or string/array combiner box or separately. Make : Solar Pulse, Phoenix / Trinity Touch / Gamesa/ Inverter OEM's make - 01 No Contd...

-

-

-

... More
(q) Supply, fabrication, installation including testing and commissioning of LT panel board out door type of size including out of MS sheet 3.15mm thick and angle 40 x 40 x 6 mm factory made weather proof / vermin proof totally including front openable pedestable type with suitable locking arrangement and coating with polystrene / epoxy powder over a coat of zinc and comprising the following items of work complete all as specified and directed :- 01 No (i) Aluminium bus bar suitable for three phase and neutral for wire system of current rating 200 Ampere and insulated with proper colour code insulation - 01 Job (ii) MCCB TPN 415 Volts of current rating 100 Ampere and rupturing capacity 25 KA - 01 No. (iii) MCB TPN 415 Volts of current rating 0-63 Amps and rupturing capacity 10 KA - 02 Nos. (iv) MCB SPN 40 Amps 230 Volts and rupturing capacity 10 KA - 02 Nos. (v) Change over switch on load type flush mounting of current rating 100 Amps four poles type without encloser - 01 No (vi) Digital type multifunction meter of size 96 Sqmm - 01 No. (vii) Indicator lamp LED type - set of three. (viii) Space for incorporating MCB TPN - 01 No. (r) Supply, install, testing and commissioning of Main distribution board Floor Mounted PDB with 1 x 63A, four pole main incomer with energy meter, indication lamps complete all as specified and directed with and including following outgoings :- 01 Job (i) 1 x 25A TPN MCB (ii) 1 x 32A TPN MCB (iii) 4 x 10A TPN MCB (iv) 4 x 6A DP MCB Contd...

-

-

-

... More
(s) Supply, install, testing and commissioning of 5 kVA UPS with battery bank for 60 minutes backup at 100 % load as per design & specifications for Solar System critical components, Industrial type Onine UPS with static switches for bypass . Make-Emerson/Delta/Eaton- 01 No (t) Supply, install, testing and commissioning of UPS distribution board of Floor Mounted UPS DB, indication lamp as per site conditions- 01 Job (i) 1 x 32 A DP MCB with 100mA ELCB main incomer with energy meter (ii) 4 x 10A DP MCB (iii) 4 x 6A SPN MCB (u) Supply & install earthing system using copper earth plate electrode & copper strips/cables of adequate size as per manufacturers instruction for protection of solar power plant complete- 01 Lot, as per manufacturers instruction. (v) Blank (w) Supply, laying and testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty with stranded aluminium conductor 33000 volts grade of 3 core 185 sqmm- 30 RM

-

-

-

... More
(x) Supplying, designing, testing and commissioning of lightening protection system covering the entire Solar Power Plant area by using ESE (Early Streamer Emission) lightening arrestor of stainless steel rod / mast, air terminal protector of 4 m height with maximum coverage area of minimum 80 m radius, level 4 with aluminium down conductor of 32 mm x 3 mm, test point and copper earthing as under :- Earthing with copper earth plate electrode of size 60cmx60cmx3mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using copper strip 20x3mm as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layer complete all as specified and directed by Engr-in-Charge. Note:- Any other items not mentioned in above description but if it is technically required for optimum performance of Solar Power Plant (SPP) shall be incorporated by the Contractor without any extra cost to the department.

-

-

-

... More
MANNING & OPERATION Comprehensive Maintenance and Operation of 1 MW Solar PV Plant during the first year at army area Rayang including connected HT/LT infrastructure round the clock (24 Hrs in 3 shifts of 08 Hrs Each) complete all as required & directed by Engr-in-Charge commencing from the next date of completion of Phase-I providing requisite manpower all as per OEM's recommendation each shift as under:- (i) One Engineer well conversant with Solar Generation and Maintenance (ii) Electrician - One No (iii) Helper - One No Note (i) :- (a) The contractor will provide sufficient manpower to ensure smooth operation and upkeep of main receiving station complete all as directed by Engr-in-Charge and to maintain power plant equipments including cleaning of PV modules in schedule basis to washout dirt from solar panels for optimum power generation. (b) The scope of work also encompass minor repairs for restoration of elect supply ie. Tightning of jumpers on OH lines, replacement of blown out fuses, minor maintenance /repair of GOD and DO's, repair to broken ACSR conductors, removal of fallen trees on OH lines and HT/LT UG cables, Relugging of HT/LT cables etc all as per site conditions to maintain unintrupted elect supply to the troops/station. (c) Contractor shall also be responsible for the discipline & integrity of staff deployed and shall be responsible for any lapse. Contd...

11

-

-

... More
(d) Contractor shall provide all the assistance/labour to meet break down as and when needed be deemed to be included in the rate quoted above. (e) Contactor will arrange own conveyance and communication system like mobile etc for complete solar power plant with minor consumable and expandable items and labour and tools for smooth and efficient operation round the clock for electrician for each shift for better communication. (f) Staff employed should be able to operate and use all safety equipments. Contractor will provide proper uniform, hand gloves, discharge rod, safety belt, rubber shoes, ladder and tourch all mandatory safety measures as per IE rules 1956. (g) All necessary requirments for detection / rectification of faults in HT and LT over head lines / under ground HT/LT cable circuits shall be arranged by the contractor. (h) Relevant records for complaints, breakdown, earth test register and repairs done shall be maintained all as specified. (j) All faults /breakdowns, pertaining to HT/LT shall be attended under the close supervision of contractor Engineer strictly following all safety measures as per IE rules. Non adherence may cause accident and under such circumstances, contractor shall be solely responsible. (k) Staff deployed in power house will be responsible for cleaning of yard and surrounding area. Note (ii) :- Any other items/parts required for synchronisation and load sharing purpose, between the SPP and the Elect Grid, which are not mentioned in above description, shall be deemed included in the above offer.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.