Military Engineer Services Tender
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.
Military Engineer Services - MES Tender
Solid Waste Management
Eprocure
Opening Date29 Oct 2024
Closing Date19 Nov 2024
Tender Amount₹ 43,50,000
Costs
EMD
₹ 87,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_671182_2Bid Award Id
ViewTender No
84325/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out in soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and as directed.
46
-
-
M & L for hardcore of broken bricks of gauge n.exc.63mm, deposited,spread and levelled in layers n exc. 15 cm thick, watered and well rammed to a true surface complete all as per specification and as directed.
27.5
-
-
M & L for Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as per specification and as directed.
1.6
-
-
M & L for Plain cement concrete (1:3:6) type D-2 using 40mm graded stone aggregate as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) concrete complete all as per specification and as directed.
16.56
-
-
M&L for 100 mm thick PCC 1:4:8 type D-2 using 40 mm graded aggregate as in sub base,complete all as specified and directed.
181.5
-
-
M&L for 100mm thick (1:2:4) Type B-1, Plain cement concrete with using 20mm graded aggregate as in hard standing etc finished with without using extra cement complete all as specified and directed.
181.5
-
-
M & L for precast cement concrete solid block masonry of grade C(5.0) with concrete M7.5 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate exceeding 10 cm in width and set in cement mortar (1:6) complete all as specified and as directed.
31.21
-
-
M&L for Rendering (Internal) 10mm thick in Cement Mortar 1:6 on Brick/ PCC Blocks or Concrete Works, finished Plastered Surfaces Even and Smooth without Using Extra Cement, complete all as specified and as directed.
50
-
-
M&L for Rendering 15mm thick on Brick/PCC Blocks or Concrete Works consisting in 2 layers, Backing/Under layer of 10mm thick in Cement Mortar 1:4 and Top layer 5.0mm thick in Cement Mortar 1:4 including mixeing WPC to Top layer, finished Fair and Even, complete all as specified and as directed. NOTE : Water Proofing Compound (WPC) will be Measured and Paid seperately.
62
-
-
Supply only Water Proofing Compound (as approved), conforming to IS:2645-2003, complete all as specified and as directed.
2.1
-
-
S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment all as specified and as directed.(Fe-410-W(Gde- E-250) quality- A)
97.5
-
-
S&F Mild Steel Plain Black Sheet 1.6mm thick in Wall Cladding, Steel Gates and Similar Work, Cut to size, Holes punched including Round Headed Screws, Clout Nails or Rivets and fixed to Wood or Steel Framing with Plain 40mm Lap Joints with riveted or welded seams including bending or turning up, mitred angles, etc. as required, complete all as specified and as directed.
8
-
-
S&F mild steel Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed .(AFe- 290 (Gde E- 165)
2611.65
-
-
S&F 4mm dia galvanised steel wire, 15x10mm or 15/20mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling, complete all as specified and as directed
120
-
-
S & F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as per specification and as directed.
211
-
-
S & F Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as per specification and as directed.
21.1
-
-
M&L for Preparing Newly Plastered Surfaces of Walls and applying Three Coats of White Wash, complete all as specified and as directed.
50
-
-
M&L for Preparing New Plastered Surfaces of Walls and applying Two Coats of Cement Base Paint (as approved Tint) over a Coat of Alkali Resistant Priming Paint, complete all as specified and as directed.
62
-
-
M&L for applying two coats of synthetic enamel paint over a coat of red oxide or zinc chromate primer including preparation of new steel or iron surfaces exc 10 cm width or girth, complete all as specified and directed.
231
-
-
M & L Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound,Grade ‘A’ complete all as per specification and as directed.
1.75
-
-
S&F mild steel works as in doors or gates of angle or other sectons with gusset plates, rails, braces etc complete drilled, welded etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging also fastening Fe 410 -W (Gde- E- 250) quality- A complete all as per specification and as directed.
95
-
-
S&F Galvanised Steel Tubing 15mm bore (dia), medium grade, conforming to IS-1239 with all Fittings, fixed to Walls, Ceiling or laid in Floors, complete all as specified and as directed.
30
-
-
M&L for 25mm th PCC 1:2:4 type B-1 using 20mm graded aggregate as in flooring, finished even and smooth without using extra cement complete all as specified & directed.
48
-
-
M&L Non-Skid Ceramic Coloured Tiles 7.0mm to 8.0mm thick (Rectangular/ Square), Area of Each Tile exc. 0.06 Sqm but not exc. 0.11 Sqm (1st quality as approved) in Floors, Jointed in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, laid over and including Screed or Screed Bed 15mm thick in Cement Mortar 1:6, complete all as specified and as directed.
48
-
-
M&L Coloured Glazed Ceramic Tiles 300x200x7.0mm thick ((1st quality as approved) in Vertical Surfaces i.e. Dado, Skirting, etc., set in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile fixing over and including Screed or Screed Bed 10mm thick in Cement Mortar 1:4, complete all as specified and as directed.
5
-
-
S&F for Rotational moulded polyethylene water storage tanks 1000 ltr cap.(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as per specification and as directed.
1
-
-
S&F 15 mm dia bib tap cast copper alloy (fency type), chromium plated, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule all as directed.
1
-
-
Removal of excavated soil not exc 50m and depositing where directed at a level n.exc 1.5m above the starting point all as directed.
21
-
-
M & L for point wiring with 1.5 Sqmm PVC insulated unsheathed 1100 Volts grade multi stranded copper conductor FRLS in PVC casing capping (ISI Marked) (Approx size 20/25/40mm width) along with all fitting/ fixtures as Tee, Bend Elbow socket, Saddles etc. complete with PVC board/ box suitable size / shaped for and accommodating modular switches sockets, regulators in white / ivory/ of white colour and with 1.50 Sqmm PVC insulated copper conductor stranded as earth wire connecting to earth dolly including MS box 3mm thick with 3mm hylum sheet cover for fixing of switches/sockets/fan regulators etc, complete all as specified for the following: -
-
-
-
One ligh/bell/ceiling fan/exhaust fan point controlled by one switch
14
-
-
One 3/5 pin socket 5 Amps on the same board with other switches with cables 1.5 sqmm size.
3
-
-
One 3/5 pin socket 5 Amps, independent, with cables 1.5 sqmm size.
2
-
-
All as per item No 32 above but for 3/5 pin socket outlet 5/15 Amps, independent with 2.5 Sqmm single core PVC insulated unsheathed 1100 Volts grade multi stranded copper conductor FRLS complete with 1.50 Sqmm stranded copper conductor PVC insulated unsheathed earth wire and connecting to earth dolly complete all as specified and directed.
3
-
-
Supply and fixing in t of MCB ,SP 06 to 32 Amps C series 10 KA breaking capacity 240 Volts. Make:- Legrand/ L&T/SEMENS.
6
-
-
Supply and fixing in replacement of MCB ,SPN 10 to 40 Amps C series 10 KA breaking capacity 240 Volts. Make:- Legrand/L&T/SEMENS.
3
-
-
M & L for submain wiring with two run single core PVC insulated unsheathed cable 1100 volts, grade having stranded copper conductor of 6 sqmm nominal cross sectional area FRLS drawn through PVC casing and capping including one run of single core PVC insulated unsheathed copper conductor of size 4 Sqmm for earth continuity conductor connected to earth dolly complete all as specified and as directed. Note :- I. Two runs of Copper Conductor of PVC insulated unsheathed 6 Sqmm and one run of size 4 Sqmm PVC insulated unsheathed copper wire & PVC casing caping will be measured as a single length.
30
-
-
S&F in replacement lumiline plus LED fittings 20 watt, extruded aluminium housing frame including necessary electric connection from ceiling rose to light fitting. (Make : Havells Model No LUMILINEBS20WLED830SPCWH or equivalent in approved manufacturers list)
10
-
-
S & F switch piano flush type single pole, one way 230 Volts AC 5/6 Amps, complete all as specified and as directed.
17
-
-
S&F socket outlet flush type 2 in 1, 3 pin, 5 Amps, 230 Volts AC including necessary connection complete all as specified and as directed.
3
-
-
S & F switch socket combination 5 pin, 5 Amps (multi plug) flush type 230 Volts complete all as specified and as directed.
2
-
-
S & F switch socket combination 5 pin, 5 Amps/16 Amps (multi plug) flush type 230 Volts complete all as specified and as directed.
3
-
-
S & F ceiling rose surface type bakelite 65x50 mm two to three terminal suitable for 230 Volts AC 6 Amps, complete all as specified and as directed.
4
-
-
S & F in replacement of distribution board sheet metal enclosure factory made fixed flush with wall inside the nitches or outside on wall surface suitable for mounting isolators & MCB's etc. 240 Volts, 200 Amps rated bus bar capacity SPN 4 way Double door complete all as specified and as directed. Make -Legrand/L&T/BCH
3
-
-
Supply & fixing LED street light fitting 35W including LED lamp pressure die cast aluminum IP66 with surge protection device of 10KV, IK7 LED (SEOUL) 6500K and connecting electrical to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75mm 3 core complete all as specified and directed including bracket and fixing clamps etc. Make Havells/ Philips/ CG/ C&S
4
-
-
Supply and laying 1100 Volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape or overall PVC sheathed in service connection suspended by insulating hangers not more than 1 meter apart including 4 mm dia GI suspension wire, 2 core cable 16 Sqmm stranded aluminium conductor cable flat or circular complete all as specified and as directed.
22
-
-
Earthing complete with GI earth plate electrode 60cm x 60cm x 6mm thick buried in ground vertically to a depth not less than 2.25 meters below ground level with the top edge of earth plate not less than 1.5 meters below ground level connected to galvanised iron earth wire 4mm dia by means of bolts, nuts, check nuts, washers maade out of galvanised iron steel all as shown in electrical plate No 3 of SSR Part I and earth wire protected by galvanised pipe light grade 15mm bore and connected to LT panel/ pole through test point including necessary earth work and excavation in any type of soil, GI light grade 15mm bore watering pipe with funnel and wire brush, PCC 1:2:4 type B1 chamber with 20mm thick RCC 1:2:4 type B1 , covere slab with 6mm dia MS bars at 100mm c/c both ways with MS hook 6mm dia etc complete all as specified and directed and testing on complete.
2
-
-
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil complete all as specified and as directed.
177
-
-
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed.
177
-
-
Making connection of PP-R distribution branch with PP-R main of following sizes by providing and fixing tee including cutting and making fusion joint etc complete all as directed.
1
-
-
Supply & laying 3 layer PP-R pipes of outer dia 32 mm
400
-
-
Supply & laying 3 layer PP-R pipes of outer dia 25 mm
40
-
-
Supply and fixing PP-R Gate valves (Brass Insert) of outer dia 32 mm.
1
-
-
Supply and fixing PP-R Gate valves (Brass Insert) of outer dia 25 mm.
1
-
-
M&L Cutting Existing Road not exc. 1.50 Metre in depth and not exc. 1.50 Metre wide including Making Good the same to match the Original Surface level with Cement Concrete after laying of Cables, Well Ramming and leveling in layers, etc., complete all as specified and as directed.
NOTE : Cement Concrete will be Measured and Paid separtely under appropriate Item.
12
-
-
Supply & Laying XLPE insulated, PVC sheathed, Heavy duty, armoured with multi-stranded Aluminium Conductor Electric Cable, 1100 Volt grade, having Cross-sectional Area 25 Sqmm 3.5 Core, conforming to IS:7098 (Part-1), laid in Tenches or fixing to Electric Poles or Passing through Pipes/ along Walls/ Roof/ across Drains/ Culvert, complete all as specified and as directed. NOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items
400
-
-
M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.
NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
29
-
-
M & L for bricks covering to underground electric cable using sub class ‘B’ bricks, laid dry, flat, perpendicular to the direction of cable complete.
3.13
-
-
M&L Galvanised Steel Tubing Pipe 50mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
12
-
-
Supply, Installation & Commissioning Feeder Pillar Box Factory Made (CPRI approved Manufacturer), made out of 3.15mm thick for Load Bearing and 2.00mm thick for Non-load Bearing CRCA Sheet, Outdoor Cubical type, with Locking Arrangement, Fully Compartmentalized, Totally Enclosed Weather and Vermin Proof suitably ventilated 440 Volts, 50 Cycles, AC Supply having IP-54 Protection as per IS-2147 of 1962 with Pre-treatment and Powder Coated of approved Colour with Mild Steel Angle Iron 40x40x5.0mm Frame Work/ Supports, grouting Legs in Cement Concrete 1:2:4 (20mm graded stone aggregate) Block of size 300x300x450mm including necessary Formworks, Earth Works, etc., Providng all Electric Connections and Testing, complete all as specified and as directed and Comprising with including to accumodating the followings:-
(a) Copper Bus-bar 4 Strip, 400mm long, 100 Amp, 415 Volt - 01 Set
(b) MCCB 25 Amp, 4 Pole , 25 kA, 230 Volt - 01 No.
(c) MCCB 3 Pole 16 Amp, 16 KA Pole, 25 kA, 415 Volt - 03 No. (d) Automatic Star Delta starter 3 Phase for 2-5 HP Pump/Motor-02 set (e) Digital Amp Meter 0-40 Amp with CTs of suitable ratio & Selector - 03 No. (f) Digital Volt Meter 0-500 Volt - 01 set (g) Indicating Lamp (RYB), LED type - 01 Set
1
-
-
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed.
4
-
-
Supply, Installation & testing Environmental Friendly Solid Waste Disposal plant comprising the followings machineries/ equipments : - (i) Fuel Free Incinerator with accessories made up of Stailness Steel/Mild Steel Body and components with 100 Kg/Hr waste burning capacity including installation of ecoflame diesel burner with the incinerator : - 01 Quantity. (ii) Organic / Kitchen Waste Shredder Machine with accessories and waste processing capacity of 100-150 Kg/hr with 3 HP Motor :- 01 Quantity. (iii) Garden/Grass Waste Sheddder Machine with accessories and waste processing capacity of 200-300 Kg/hr with 5 HP Motor :- 01 Quantity.