Military Engineer Services Tender
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.
Military Engineer Services - MES Tender
Eprocure
Opening Date1 Aug 2023
Closing Date30 Mar 2024
Tender Amount₹ 1,75,00,00,000
Costs
EMD
₹ 15,00,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Summary
Provn Of Otm And Runway At Likabali Military Station Under Ge 872
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_611592_1Bid Award Id
ViewTender No
CESZ/LIKA/ OF 2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III.
1
-
1376200.87
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIFICATIONS as listed in Schedule ‘A’ Part-IV.
1
-
3122132.55
Lumpsum price worked out by the tenderer for ROADS / PATH / CULVERT / FOOTPATH as listed in Schedule ‘A’ Part-V.
1
-
36342794.54
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI.
1
-
101191439.55
Lumpsum price worked out by the tenderer for COMPOUND WALL/ FENCING/GATE as listed in Schedule ‘A’ Part-VII.
1
-
9323325.33
Lumpsum price worked out by the tenderer for RETAINING WALL as listed in Schedule ‘A’ Part-VIII.
1
-
91446083.4
Lumpsum price worked out by the tenderer for RIGID RUNWAY/LINK TAXI TRACK/DISPERSAL as listed in Schedule ‘A’ Part-IX.
1
-
344877988.2
Lumpsum price worked out by the tenderer for BUTT WALL OF RUNWAY as listed in Schedule ‘A’ Part-X.
1
-
15204899.14
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-XI.
1
-
10356085.57
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-XII.
1
-
2955928.59
Lumpsum price worked out by the tenderer for HOT WATER SUPPLY as listed in Schedule ‘A’ Part-XIII.
1
-
611834.4
Lumpsum price worked out by the tenderer for REFRIDGERATOR DEEP FREEZER AND WATER COOLER as listed in Schedule ‘A’ Part-XIV.
1
-
392489.73
Lumpsum price worked out by the tenderer for FIRE FIGHTING SYSTEM as listed in Schedule ‘A’ Part-XV.
1
-
6967562.4
Lumpsum price worked out by the tenderer for FIRE ALARM SYSTEM as listed in Schedule ‘A’ Part-XVI.
1
-
1779017
Lumpsum price worked out by the tenderer for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-XVII.
1
-
185535.6
Lumpsum price worked out by the tenderer for DEMOLITION/DISMANTLING/TAKING DOWN as listed in Schedule ‘A’ Part-XVIII.
1
-
925989.35
Sch 'A' Sec-XIX (Miscellaneous Items)Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
-
-
-
Bringing approved earth (as approved by Garrison Engineer) from sources outside defence land including all cost such as royalty if any , transportation ,taxes,etc. for area filling / area development upto MGL level including raising of original ground level upto MGL by approved earth and including spreading in layers not exc 30cm thick each layer ,watering , compaction with 8 tonne to 12 tonne power roller and finished to required size and shape etc.
Notes:
(i) Earth required for the item, shall be supplied by contractor, from out side MOD land of any lead, at his own own arrangement.
(ii) All cost of procurement of earth including cost of transportation, compaction, royalties, tax etc shall be deemed to be included in the unit rate quoted by the contractor.
(iii) With reference to clause 3.6 of MES part-II on serial page No-21 it is clarified that measurement of the above item shall be of finished embankment /traverse of filled earth after consolidation /compaction and 5% deduction shall be made from measured and calculated volume to allow for increase in bulk.
39699.73
-
-
Preparation of unsurfaced WMM surface by brushing with wire brushes for removing caked mud etc, Sweeping with brooms and finaly fanning the cleaned surface with gunny bags to remove all loose, dirt etc complete all as specified and directed
2615.69
-
-
S&F shutter proof weather proof and impact resistance convex safety traffic mirror of size 24” dia with 40mm dia Stainless Steel pipe including arrangement of fixing at above ground level complete all as specified and directed
10
-
-
M & L Geo textile complete all as specified and directed.
6876
-
-
M&L for in-situ stabilization of 500 mm in three layers of 2x150mm and bottom layer of 200mm thick, sub grade soil by uniform mixing of cement OPC 43 Grade @ 05 % by weight of soil as per mix design ( 5% percentage of cement taken for estimation, actual type of additive and percentage of blending to be given in mix design). Mix design should also contain recommended quality control tests with their frequencies. item will include pulverization of soil, spreading of additive, blending mix by tractor towed rotovator, addition of water/ drying of mix to required moisture content and compaction using suitable vibratory roller to required 98% Maximum Dry Density complete all as specified and directed. Relevant provisions of IRC: SP89-2010 be referred to for this item
48372.5
-
-
M&L for 300 mm thick (compacted thickness) Granular Sub Base Course (GSB) Grade V in two layers of 150 mm thick), (as per table 400-1 and 400-2 of MORTH specifications for Road and Bridge works) over compacted subgrade with stone aggregates by using motor grader, spreading, levelling and rolling with vibratory roller of capacity 80-100 KN static weight for achieving required compaction density of atleast 98% of max dry density and consolidating to required gradient and camber complete all as specified and directed. Finished surface tolerances shall be as per table 900-1 of MoRTH specifications for Road and Bridge works 2013.
9674.5
-
-
Supply and Laying (no additional payment for overlap) 400 micron thick HDPE sheet (Virgin Quality) having minimum weight 390 gm/sqm over sand cushion as specified in the design with overlap between adjacent strips as minimum 100mm and transverse joints at ends as minimum 150mm etc complete as specified and directed.
96745
-
-
Supply only non-circular synthetic fibre reinforment fibres complete all as specified and directed
21767.63
-
-
M&L for non- perforated HDPE/PVC pressure pipe top to 2/3 portion perforated and bottom 1/3 non perforated including fittings such as sockets/coupline/Tea etc of 06 Kgf/Sqcm, 150mm dia complete all as specified and directed
2870
-
-
M&L for semi perforated HDPE/PVC pressure pipe top to 2/3 portion perforated and bottom 1/3 non perforated including fittings such as sockets/coupline/Tea etc of 06 Kgf/Sqcm, 150mm dia complete all as specified and directed
2382
-
-
M&L for preparation of new previously untreated concrete surfaces of any description over 10cm girth or width, not otherwise described and applying two coat of Painting lines, dashes, arrows, letters, etc. on roads, pavements and the like exc 10cm wide with road marking paint, white or golden yellow complete all as specified and directed
8204.28
-
-
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI wire 4mm dia as earthing lead connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layers complete as shown in electrical plate No. 3 of SSR Part-I all as specified and directed .
20
-
-
M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One light/fan/Bell point controlled by one,one way switch complete all as specified and directed
1341
-
-
M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One light point controlled by two ,two way switch complete all as specified and directed
16
-
-
M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One socket outlet point 6 A on independent board complete all as specified and directed
271
-
-
M & L for Concealed Point wiring with 4.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches & socket, including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 04 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for one 16 Amp socket outlet on independent board complete all as specified and directed
179
-
-
S&F piano switch single pole flush type 6 Amp,two way, 230 Volt, complete all as specified and directed
32
-
-
M & L for Sub main Wiring with two run of 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and including PVC Conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly complete all as specified and directed. Note: Two single core cable and one No. earth wire and one run of conduit shall be measured together as one length
1985
-
-
M & L for Sub main Wiring with two run of 4.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and including PVC Conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 4.0 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly complete all as specified and directed. Note: Two single core cable and one No. earth wire and one run of conduit shall be measured together as one length
750
-
-
M & L for Sub main Wiring with four run of 4.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and including PVC Conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 4.0 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly complete all as specified and directed. Note: Four single core cable and one No. earth wire and one run of conduit shall be measured together as one length
300
-
-
M & L for Sub main Wiring with four run of 6.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and including PVC Conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 6.0 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly complete all as specified and directed. Note: Four single core cable and one No. earth wire and one run of conduit shall be measured together as one length
150
-
-
M & L for Sub main Wiring with four run of 10.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and including PVC Conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 10.0 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly complete all as specified and directed. Note: Four single core cable and one No. earth wire and one run of conduit shall be measured together as one length
100
-
-
Supply and fix epoxy powder coated Distribution Board VTPN 4way, 12 module vertical type with Incomer as MCCB 125 Amps and outgoing MCBs with common bus-bar at incoming end of outgoing MCBs grouted/ flush to wall complete all as specified and directed.
4
-
-
S&F sheet metal enclosure DB SPN 240 Volts 6 Way with 200 amps rated bus bar double door type complete all as specified and directed.
9
-
-
S&F Blank Plate for MCB DB of required size complete all as specified and directed.
12
-
-
S&F LED New Adore 10W B22 WW Ball lamp complete all as specified and as directed.
76
-
-
S&F Linear & compact 9W LED mirror light with decorative grey end caps, polycarbonate body and ribbed opal diffuser with all fixing accessories, screws etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed
16
-
-
S & F Energy saving surface/pendent mounting LED bulk head light fitting, 1 x 20 watt, 230 volts, with electronic driver and with best quality diffuser high lumen output, 2.5 KV voltage surge protection, PF 0.98, THD 10% complete with all accessories including and connecting of with twin core of PVC insulated 0.75 Sqmm copper conductor cable complete all as specified and directed
4
-
-
M&L Earthing with Copper Electrode 600x600x3.15 mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Copper strip 20 x 3 mm by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 25mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed.
18
-
-
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 25 x 4mm as earthing lead connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 32mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layers complete as shown in electrical plate No. 3 of SSR Part-I all as specified and directed.
36
-
-
M& L for sand cushioning in trenches for protection of under ground cable provided in layers of sand as 8 cm before laying the cable and 15 cm deep after laying cable complete all as specified and directed.
Note : Punned thickness shall be measured and paid.
680
-
-
Supply and laying well burnt sub class ‘B’ bricks ( designated 75) locally available best quality, laid dry in trenches for protection of underground cable complete all as specified and directed
58100
-
-
Supply, installation testing and commissioning of 315 KVA outdoor transformer , step down 11KV/433V energy efficiency level-3 as per IS: 1180 of 2014 Part-I, 3 Phase 50 C/S AC double wound core type, copper wound, oil immersed naturally cooled (ONAN) with external cooling tubes/fins, delta/star connection on primary side (11KV) , and star connection on secondary side (433V) in accordance with vector symbol DYN-11 and having tapping at +/- 2.5%, +/- 5% and +/-7.5% to be changed by means of manually operated Off Load Tap Changing gear. The rate of temperature rise after continuous full load shall be all as specified in IS -2026. (Locaton : Admn Accn) The transformer shall be complete with the following:-
(a) Cable entry box for LT on secondary side for suitable LT cable and HT on primary side for suitable HT cable including fixing arrangement as specified and directed by Engineer-in-Charge.
(b) Oil conservator with filling cap, drain valve and oil level gauge.
(c) Dehydrating breather with connecting pipe, first fill of dehydrating agent and oil seal.
(d) Explosion relief vent mounted on tank with double diaphragm and equiliser pipe connection to conservator air space (pressure release device).
(e) Air relief plug.
(f) Thermometer pocket.
(g) 100 mm dial type temperature indicator having range 0-120 degree C vapour pressure
type with maximum reading pointer/Max temp indicator and resetting device.
(h) Two earthing terminals on transformer body to suit 32 mm x 6mm GI strip.
(j) Rating and diagram plate.
(k) Drain valve with threaded adopter.
1
-
-
ITEM NO 19.33Cont... (l) Filter valve with threaded adopder (top and bottom).
(m) Sample valve.
(n) Inspection covers.
(o) Lifting lugs.
(p) Four plain rollers, bidirectional, hinged type at the bottom for shifting transformer from one place to another place.
(q) Top cover lifting eyes.
(r) Extra bushing outside the cable box for providing independent earthing(neutral earthing).
(s) First fill of transformer oil conforming to IS-335 of dielectric strength minimum 42KV/cm (r.m.s.).
(t) Rail section and channel emdedded in foundation of suitable size in and including PCC platform of size 2.0m x 2.0m x 1.5m (PCC 1:3:6, Type C2) as per IS 1180 (part-I) or as per manufacturers recommendations & requisite earthwork shall be included in the quoted rate.
-
-
-
Supply, installation testing and commissioning 500 KVA outdoor type transformer, step down 11KV/433V energy efficient level-3 as per IS: 1180 of 2014 Part-I, 3 Phase 50 C/S AC double wound, core type copper wound, oil immersed naturally cooled (ONAN) with external cooling tubes, delta/star connection on primary side (11KV) , and star connection on secondary side (433V) in accordance with vector symbol DYN-11 and having tapping at +/- 2.5%, +/- 5% and +/-7.5% to be changed by means of manually operated OFF LOAD tap changing gear. The rate of temperature rise after continuous full load shall be all as specified in IS -2026. (For Admn Accn)
The transformer shall be complete with the following:-
(a) Cable entry box for LT on secondary side for suitable LT cable and HT on primary side for suitable HT cable including fixing arrangement as specified and directed by Engineer-in-Charge.
(b) Oil conservator with filling cap, drain valve and oil level gauge.
(c) Dehydrating breather with connecting pipe, first fill of dehydrating agent and oil seal.
(d) Explosion relief vent mounted on tank with double diaphragm and equiliser pipe connection to conservator air space (pressure release device).
(e) Air relief plug.
(f) Thermometer pocket.
(g) 100 mm dial type temperature indicator having range 0-120 degree C vapour pressure
type with maximum reading pointer/Max temp indicator and resetting device.
(h) Two earthing terminals on transformer body to suit 32 mm x 6mm GI strip.
(j) Rating and diagram plate.
(k) Drain valve with threaded adopter.
(l) Filter valve with threaded adopder (top and bottom).
1
-
-
ITEM NO 19.35Cont... (m) Sample valve.
(n) Inspection covers.
(o) Lifting lugs.
(p) Four plane rollers, bidirectional, hinged type at the bottom for shifting transformer from one place to another place.
(q) Top cover lifting eyes.
(r) Extra bushing outside the cable box for providing independent earthing(neutral earthing).
(s) First fill of transformer oil conforming to IS-335 of dielectric strength minimum 42KV/cm (r.m.s.).
(t) Rail section and channel emdedded in foundation of suitable size in and including PCC platform of size 2.0m x 2.0m x 1.5m (PCC 1:3:6, Type C2) as per IS 1180 (part-I) or as per manufacturers recommendations & requisite earthwork shall be included in the quoted rate.
-
-
-
Supply, install commisioning and testing of APFC panel 150 KVAR with 6 steps (2x12.5 + 3x25 + 50) with MPP-H and MCCB as incomer manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed.
1
-
-
Supply, install commisioning and testing of APFC panel 300 KVAR with 6 steps (1x100 + 3x50 + 2x25) with MPP-H and MCCB as incomer manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed.
1
-
-
M&L SMS (sheet moulding compound) junction boxes surface mounting hinged door type with reteict type locking arrangement having size 200x300x120mm fixed to steel tubular pole with 02 Nos MS flat clamps 30x3mm suitable nuts & bolts and bottom blanking plate with 2 Nos cable glands suitable for 3.5 x 25 Sq mm cable XLPE armoured cable and mounted inside with 4 Nos epoxy moulded brass studs nuts & bolts and check nuts for connecting / looping of cable and one arial fuser of bakelite body 6 amps and PVC insulated cable to twin core 2.5 Sqmm with multistranded copper conductor cable 8.5 mtr through inside the pipe and connected complete all as specified and as directed.
57
-
-
Supply, install commisioning and testing of cubical indoor feeder LT panel board (Blast Pen) manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 2.00 mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:-
Incomming (a) MCCB 250 Amp, 3 Pole 36 KA - 01 N0
Out Going
(a) MCCB 63 Amp, 4 Pole 16 KA - 06 Nos
(b) MCCB 16 Amp, 3 Pole 16 KA - 06 Nos
(c) Digital Ammeter with selector switch & CTS - for main incoming
(d) Digital Volt meter with selector switch (e) RYB indicating lamps ( RYB) - 01 set
1
-
-
Supply, install commisioning and testing of cubical indoor feeder LT panel board (Dispersal panel) manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:-
Incomming (a) MCCB 200 Amp, 3 Pole 25 KA - 01 N0
Out Going
(a) MCCB 63 Amp, 4 Pole 16 KA - 02 Nos
(b) MCCB 32 AmP, 3 Pole 16 KA - 02 Nos
(c) Digital Ammeter with selector switch, CTS - (d) Digital Volt meter with selector switch (e) RYB indicating lamps ( RYB) - 01 set
2
-
-
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:-
Incomming (a) ACB 800 Amp, 4 pole,50 KA 415 V manual drawout type with microprocessor release - 01 No
Out Going
(a) MCCB 200 Amp, 3 Pole 36 KA - 01 No
(b) MCCB 100 Amp, 3 Pole 16 KA - 03 No
(c) MCCB 63 Amp, 3 Pole 16 KA - 03 No
(d) MCCB 32 Amp, 3 Pole 16 KA - 01 No
(e) MCB 6 Amp, 3 pole , 6 KA ( streetLight) - 01 N0
(f) Time switch 20 Amp - 01 N0
(g) Digital Ammeter 3 phase - 01 N0 (h) Digital Volt meter 3 phase - 01 N0 (j) RYB indicating lamps ( RYB)
1
-
-
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:-
Incomming (a) MCCB 125 Amp, 4 Pole 16 KA - 01 No
Out Going
(a) MCB 6 Amp, 230V, 2 POLE 10 KA - 01 No
(b) MCB 6 Amp, 2 POLE 10 KA - 01 No
(c) MCCB 100 Amp , 3 POLE 16 KA - 01 No
(d) MCCB 32 Amp, 3 POLE 16 KA - 01 No
1
-
-
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:-
Incomming (a) MCCB 100 Amps , 4 Pole 16 KA - 01 No
Out Going (a) MCB 16 Amp, 2 Pole 10 KA - 01 No (b) MCB 6 Amp, 2 Pole 10 KA - 01 No (c) MCB1 6 Amp, 2 Pole 10 KA- 01 No (d) MCB 6 Amp, 2 Pole 10 KA - 01 No
1
-
-
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:-
Incomming (a) MCCB 250 Amp ,4 Pole , 36 KA - 01 No
Out Going
(a) MCCB 100 Amp, 3 Pole 25 KA - 01 No
(b) MCB 6 Amp, 2 Pole 10 KA - 01 No
(c) MCB 63 Amp, 3 Pole 25 KA - 01 No
(d) MCB 16 Amp, 2 Pole 10 KA - 01 No
(e) MCB 32 Amp, 2 Pole 10 KA - 01 No
1
-
-
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:-
Incomming (a) MCB 63 Amp 2 Pole 25 KA - 01 No
Out Going
(a) MCB 6 Amp, 2 Pole 10 KA - 01 No
(b) MCB 16 Amp, 2 Pole 10 KA - 01 No
(c) MCB 16 Amp, 2 Pole 10 KA - 01 No
1
-
-
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:-
Incomming (a) MCCB 250, Amp 4 Pole, 25 KA - 01 No
Out Going
(a) MCCB 125 Amp, 3 Pole 25 KA- 01 No
(b) MCCB 125 Amp, 3 Pole 25 KA - 01 No
1
-
-
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:-
Incomming (a) ACB 3200 Amp, 4 Pole, 75 KA Manual drawout type with microprocessor release - 01 No
Out Going
(a) MCCB 800 Amp, 3 Pole, 50 KA - 01 No
(b) MCCB 800 Amp, 3 Pole, 50 KA- 01 No
(c) MCCB 800 Amp, 3 pole, 50 KA - 01 No
(d) MCCB 200 Amp, 3 Pole 25 KA - 01 No
(e) MCCB 63 Amp, 3 Pole 25 KA - 01 No
(f) MCB 6 Amp, 3 pole , 6 KA - 01 No
(g) Time switch 20 Amp - 01 No
(h) Digital Ammeter 3 phase - 01 No
(j) Digital Volt meter 3 phase - 01 No
(k) RYB indicating lamps ( RYB) - 01 set
1
-
-
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:-
Incomming (a) ACB 1000 Amp, 4 Pole, 50 KA Manual drawout type with microprocessor release - 01 No
Out Going
(a) MCB 16 Amp, 2Pole, 10 KA - 02 Nos
(b) MCCB 800 Amp, 3 Pole, 50 KA - 01 No
(c) MCB 16 Amp, 3 Pole , 10 KA - 01 No
(d) MCB 16 Amp , 3 Pole 10 KA - 01 No
1
-
-
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:-
Incomming (a) MCCB 400 Amp 4 Pole 36 KA - 01 No
Out Going
(a) MCCB 200 Amp, 3 Pole, 36 KA - 01 No
(b) MCB 6 Amp, 2 Pole, 10 KA - 01 No
(c) MCCB 100 Amp, 3 Pole 16 KA - 01 No
1
-
-
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:-
Incomming (a) ACB 1000 Amp, 4 Pole, 50 KA Manual drawout type with microprocessor release - 01 No
Out Going
(a) MCCB 800 Amp, 3 Pole, 50 KA - 01 No
(b) MCB 16 Amp, 2 Pole, 10 KA - 02 Nos
(c) MCB 6 Amp, 2 Pole, 10 KA - 01 No
(d) MCCB 63 Amp , 3 Pole 25 KA - 01 No
1
-
-
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:-
Incomming (a) MCCB 250 Amp 3 Pole 36 KA - 01 No
Out Going
(a) MCCB 160 Amp, 3 Pole, 36 KA - 01 No
(b) MCB 16 Amp, 3 Pole, 10 KA - 01 No
(c) MCB 6 Amp , 2 Pole 10 KA - 01 No
(d) MCB 32 Amp, 2 Pole 25 KA - 01 No
1
-
-
Supply, install commisioning and testing of cubical outdoor feeder LT panel board with powder coated finishing platform mounted factory made totally enclosed dust and vermanufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:-
Incomming (a) MCCB 80 Amp, 4 Pole 25 KA - 01 No
Out Going
(a) MCCB 32 Amp, 3 Pole 16 KA - 01 No
(b) MCCB 32 Amp, 3 Pole 16 KA - 01 No
1
-
-
S&F PP-R (polypropylene Random Co -Polymer) gate valve (brass insert as pre requirement of the site for outer dia of pipe size 75 mm bore complete all as specified and directed.
1
-
-
S&F PP-R (polypropylene Random Co -Polymer) gate valve (brass insert as pre requirement of the site for outer dia of pipe size 110 mm bore complete all as specified and directed.
2
-
-
Construction of VALVE PIT TYPE 'A' of brick Masonry and of size 100 cm x 100 cm x100 cm (inner dimension) with all fittings and fixtures complete all as specified and as shown on drawing No. TD/EM/6 Sheet 1/2
10
-
-
Supply, installation, testing and commissioning of A.C. Generator ( Diesel Generator ) with acoustic enclosure capacity 62.5 KVA Brushless type, Synchronous, A.C. Generators continuously rated for 415 Volts, 3 Phase,4 Wire, 50 HZ, 0.8 power factor (lagging) at 1500 RPM, 4 Pole, screen protected, drip proof, horizontal foot-mounted type, self-excited, self-regulated with static excitation system, Class ‘H’ insulation. The Alternator is capable of developing rated output & able to take 10% overload for one hour at every 12 hrs of operation. The A.C. Generator ( Diesel Generator ) shall be complete with the following:-
Acoustic Enclosure :
(a) Approved by ARAI/NAL, the nodal agency of CPCB
(b) Compact, modular construction and sleek design with low noise level 75dBA, at a distance of 1 Meter from Canopy in free field conditions.
(c) Soundproof, weather-proof and environment friendly silent set.
(d) Ready-to-use silent DG Set, which eliminates need of foundation or grouting.
(e) Single bearing generator with Anti vibration mounting ensures minimal vibration.
(f) Steel outer construction with 1.6mm CRCA sheet with heavy-duty fabricated base frame and inbuilt fuel tank.
(g) Residential type exhaust silencer is mounted in the enclosure.
(h) Illumination arrangement inside the canopy.
Base Frame: - The Diesel Engine and the A. C. Generator will be mounted on a suitable base frame of sturdy to minimize vibration and ensure easy maintenance.
Fuel Tank:- Daily service fuel tank of sheet metal of suitable capacity complete with drain valve, air vent inlet and outlet connection. Batteries Battery (Dry and charged) of suitable AH capacity along with leads for connection.
Foundation: - Core Protection Engle embedded in foundation of suitable size in and including PCC/RCC platform of as per manufacturer’s recommendations & requisite earthwork shall be included in the quoted rate.
2
-
-
Supply, installation, testing and commissioning of A.C. Generator ( Diesel Generator ) with acoustic enclosure capacity 250 KVA Brushless type, Synchronous, A.C. Generators continuously rated for 415 Volts, 3 Phase,4 Wire, 50 HZ, 0.8 power factor (lagging) at 1500 RPM, 4 Pole, screen protected, drip proof, horizontal foot-mounted type, self-excited, self-regulated with static excitation system, Class ‘H’ insulation. The Alternator is capable of developing rated output & able to take 10% overload for one hour at every 12 hrs of operation. The A.C. Generator ( Diesel Generator ) shall be complete with the following:- Acoustic Enclosure :
(a) Approved by ARAI/NAL, the nodal agency of CPCB
(b) Compact, modular construction and sleek design with low noise level 75dBA, at a distance of 1 Meter from Canopy in free field conditions.
(c) Soundproof, weather-proof and environment friendly silent set.
(d) Ready-to-use silent DG Set, which eliminates need of foundation or grouting.
(e) Single bearing generator with Anti vibration mounting ensures minimal vibration.
(f) Steel outer construction with 1.6mm CRCA sheet with heavy-duty fabricated base frame and inbuilt fuel tank.
(g) Residential type exhaust silencer is mounted in the enclosure.
(h) Illumination arrangement inside the canopy.
Base Frame: - The Diesel Engine and the A. C. Generator will be mounted on a suitable base frame of sturdy to minimize vibration and ensure easy maintenance.
Fuel Tank:- Daily service fuel tank of sheet metal of suitable capacity complete with drain valve, air vent inlet and outlet connection. Batteries Battery (Dry and charged) of suitable AH capacity along with leads for connection.
Foundation: - Core Protection Engle embedded in foundation of suitable size in and including PCC/RCC platform of as per manufacturer’s recommendations & requisite earthwork shall be included in the quoted rate.
2
-
-
Supply, installation, testing and commissioning of A.C. Generator ( Diesel Generator ) with acoustic enclosure capacity 30 KVA Brushless type, Synchronous, A.C. Generators continuously rated for 415 Volts, 3 Phase,4 Wire, 50 HZ, 0.8 power factor (lagging) at 1500 RPM, 4 Pole, screen protected, drip proof, horizontal foot-mounted type, self-excited, self-regulated with static excitation system, Class ‘H’ insulation. The Alternator is capable of developing rated output & able to take 10% overload for one hour at every 12 hrs of operation. The A.C. Generator ( Diesel Generator ) shall be complete with the following:- Acoustic Enclosure :
(a) Approved by ARAI/NAL, the nodal agency of CPCB
(b) Compact, modular construction and sleek design with low noise level 75dBA, at a distance of 1 Meter from Canopy in free field conditions.
(c) Soundproof, weather-proof and environment friendly silent set.
(d) Ready-to-use silent DG Set, which eliminates need of foundation or grouting.
(e) Single bearing generator with Anti vibration mounting ensures minimal vibration.
(f) Steel outer construction with 1.6mm CRCA sheet with heavy-duty fabricated base frame and inbuilt fuel tank.
(g) Residential type exhaust silencer is mounted in the enclosure.
(h) Illumination arrangement inside the canopy.
Base Frame: - The Diesel Engine and the A. C. Generator will be mounted on a suitable base frame of sturdy to minimize vibration and ensure easy maintenance.
Fuel Tank:- Daily service fuel tank of sheet metal of suitable capacity complete with drain valve, air vent inlet and outlet connection. Batteries Battery (Dry and charged) of suitable AH capacity along with leads for connection.
Foundation: - Core Protection Engle embedded in foundation of suitable size in and including PCC/RCC platform of as per manufacturer’s recommendations & requisite earthwork shall be included in the quoted rate.
1
-
-
Supply, install, testing and commissioning of Retrofit Emmission Control Device (RECD) in 30 KVA Diesel Genset to reduce the PM, Carbon Mono-Oxide, and Hydro-Carbon elements from the emmission as per the latest CAQM Govt notification to operate the DG set in healthy working condition. The RECD should consist of DPF (Diesel Particulate Filter), DOC (Diesel Oxidation Filter), Selective Reduction Catalyst (SRC), DPF controller, differential pressure sensor, exhaust temp sensor etc.to ensure efficient regenerative technology to capture the PM 2.5 efficiently with a performance level 80-94% and hydro-Carbon upto level of 70%. The scope of work should consist of :- i). Supply of the complete Device along with control panel to site.
ii). Installation of the RECD device on the diesel genset iii). RECD testing and DG on load commissioning after fitment of RECD. iv). All related activities to ensure RECD is supplied, installed and commissioned on the DG set.
v). Providing test certificate from any 1 of the 5 labs stating that the RECD reduces PM 2.5% and makes the DG set compliant to the CAQM directive.
vi) Necessary civil work required on site to make space for the device fitment.
vii) Provision of basic electricity connection for Panel. viii) Necessary addition /alteration of existing exhaust pipes with supporting structures as required at site.
1
-
-
Supply, install, testing and commissioning of Retrofit Emmission Control Device (RECD) in 82.5 KVA Diesel Genset to reduce the PM, Carbon Mono-Oxide, and Hydro-Carbon elements from the emmission as per the latest CAQM Govt notification to operate the DG set in healthy working condition. The RECD should consist of DPF (Diesel Particulate Filter), DOC (Diesel Oxidation Filter), Selective Reduction Catalyst (SRC), DPF controller, differential pressure sensor, exhaust temp sensor etc.to ensure efficient regenerative technology to capture the PM 2.5 efficiently with a performance level 80-94% and hydro-Carbon upto level of 70%. The scope of work should consist of :- i). Supply of the complete Device along with control panel to site.
ii). Installation of the RECD device on the diesel genset iii). RECD testing and DG on load commissioning after fitment of RECD. iv). All related activities to ensure RECD is supplied, installed and commissioned on the DG set.
v). Providing test certificate from any 1 of the 5 labs stating that the RECD reduces PM 2.5% and makes the DG set compliant to the CAQM directive.
vi) Necessary civil work required on site to make space for the device fitment.
vii) Provision of basic electricity connection for Panel. viii) Necessary addition /alteration of existing exhaust pipes with supporting structures as required at site.
2
-
-
Supply, install, testing and commissioning of Retrofit Emmission Control Device (RECD) in 250KVA Diesel Genset to reduce the PM, Carbon Mono-Oxide, and Hydro-Carbon elements from the emmission as per the latest CAQM Govt notification to operate the DG set in healthy working condition. The RECD should consist of DPF (Diesel Particulate Filter), DOC (Diesel Oxidation Filter), Selective Reduction Catalyst (SRC), DPF controller, differential pressure sensor, exhaust temp sensor etc.to ensure efficient regenerative technology to capture the PM 2.5 efficiently with a performance level 80-94% and hydro-Carbon upto level of 70%. The scope of work should consist of :- i). Supply of the complete Device along with control panel to site.
ii). Installation of the RECD device on the diesel genset iii). RECD testing and DG on load commissioning after fitment of RECD. iv). All related activities to ensure RECD is supplied, installed and commissioned on the DG set.
v). Providing test certificate from any 1 of the 5 labs stating that the RECD reduces PM 2.5% and makes the DG set compliant to the CAQM directive.
vi) Necessary civil work required on site to make space for the device fitment.
vii) Provision of basic electricity connection for Panel. viii) Necessary addition /alteration of existing exhaust pipes with supporting structures as required at site.
2
-
-
Supply, installation, commissioning refrigerator electric driven single phase capacity more than 195 litres upto 310 litres (+ 2%) frost free, Triple door, BEE five star rated complete all as specified and directed
2
-
-
Supply, installation, commissioning refrigerator electric driven single phase capacity more than 310 litres upto 360 litres (+ 2%) frost free, Triple door, BEE five star rated complete all as specified and directed
1
-
-
S & F voltage stabilizer for automatic operation single phase, naturally air cooled indoor type designed for input variation between 90 v to 300 v with outputvoltage stabilizeat 230 with accuracy of ( +) (-) 2.2 % and capacity of 1 KVA complete all as specified and directed
14
-
-
Supply and install Air cooled spilt air conditioner Inverter type electric driven, single phase of capacity of 1.5 TR, 5 star rated complete with indoor and out door unit complete all as specified and as directed.
6
-
-
Supply and install Air cooled spilt air conditioner Inverter type electric driven, single phase of capacity of 2 TR, 5 star rated complete with indoor and out door unit complete all as specified and as directed.
15
-
-
2) S & F voltage stabilizer for automatic operation single phase, naturally air cooled indoor type designed for input variation between 90 v to 300 v with outputvoltage stabilizeat 230 with accuracy of + or - 2.5% and of capacity 5 KVA complete all as specified and as directed.
21
-
-
S & F Single phase motor starter 240 v 50 Hz AC only 25 A suitable upto 2 Ton ACs complete all as specified and directed.
21
-
-
Supply and Install Electric driven fire pump horizontal end suction , centrifugal type,CI casing and bronze impeller stainless steel shaft, suitable for delivering 4560 LPM, 70 meter head ,1480 RPM complete all as specified and directed.
1
-
-
Supply and Install Diesel Engine driven fire pump horizontal end suction , centrifugal type,CI casing and bronze impeller stainless steel shaft, suitable for delivering 4560 LPM, 70 meter head,2300 RPM complete all as specified and directed.
1
-
-
Supply and Install Electric Driven Jockey pump delivering 180 LPM above 70 meter head up to 90 meter head complete all as specified and directed.
1
-
-
Supply and fix Valve, butterfly conforming to IS 13095,300 mm (12”) dia. complete all as specified and directed.
10
-
-
Supply and fix Valve, reflux, with by-pass Arrangement, 300 mm (12”) dia complete all as specified and directed.
5
-
-
Supply and fix Strainer Y type conforming to IS, size 300 mm (12”) dia. complete all as specified and directed.
6
-
-
Cast Iron Air Valves with two air Outlets, 150 mm dia bore and fixing Up in cast iron water supply mains complete all as specified and directed.
1
-
-
Supply and lay pipe galvanized, “Heavy class”, including fittings, 25 mm (1”) dia. complete all as specified and directed.
1400
-
-
Supply and fix hose box for hose reel of 20 mm size of 30 meter length complete with coupling branch pipe and nozzle , MS sheet 2 mm thickness complete all as specified and directed.
18
-
-
Supply and fix 63 mm dia gun metal branch pipe with 12.5 mm nozzle conforming to IS 903 complete all as specified and directed.
18
-
-
Supply and fix branch pipe with nozzle of 20 mm dia for hose reel conforming to IS 8090 complete all as specified and directed.
18
-
-
Supply and fix Gun metal fire brigade in let connection for connecting to external fire hydrant ring main consisting of two nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia, flanged outlet complete with all accessories complete all as specified and directed.
12
-
-
Supply and fix MS cabinet (approx 750mm x 600mm x 450mm) to encl fire brigade inlet connections fabricated from 16 gauge sheet with full front glass door and locking arrangement painted and mounted on masonry platform complete all as specified and directed.
12
-
-
Supply only trolly mounted water mist capacity of 35 Ltrs fire suppression system complete all as specified and directed.
2
-
-
Supply only electrical fire extinguishing equipment 5 Kg capacity suppression syatem all as specified. 05 Rooms one extingusher complete all as specified and directed.
11
-
-
Supply and fixing water flow switch for sprinkler branch system for sensing of water flow suitable for 25 mm GI pipe line for suppression system complete all as specified and directed.
3
-
-
Supply and fixing UPS for fire panel of capacity 900 VA with standard accessoriescomplete all as specified and directed.
1
-
-
Main fire pump panel cum fire fiting control panel : adequate size cable alley shall be provided all around the panel and in the back for each cable bending and termination. The panel shall be fabricated by CPRI approved vendor. The outgoing feedres inside the panel shall be coneected through solid bus bar. flexible cable links are not acceptable Bus bar shall be provided with heat shrinkable sleeves and shall be colour code. The panel shall be suitable for cable entry from top. The minimum fault rupturing of all incoming and outgoing switches/breaker shall be 35 KA. the panels shall be fabricated after the approval of fabrication drawings.
All switchgears and bus bar to be used of siemens, schnieder, ABB make only
In panels :- All cable s used to be FR type. Cables of delivering 20% higher capacity to be selected.
Incoming Section
(i) MCCB 630 A (50 KA)- 1 No
(ii)1000 Amps copper bus bar shall be insulated with heat shrinkale sleeves and shall be color code for three phase and 1200 Amp for neutral.
(iii)current transformer (400/5A)-1 No
(iv) multifuction meter with selector switch-1 No
Outgoing (i)MCCB,430A, 4 pole (50A)-1No
(ii)Star delta starter
(iii) Bypass arrangement
(iv)All necessary protection to be planned
3
-
-
ITEM NO 19.87 CONT..
(v)Selection of electrical panel to be submitted and approvals to be taken from appointed TAC (Testing Auditing and Consulting) firm, before the procurement of pumps. Decision of TAC will be final and adhering for firm in selection. Technical specifications shall be seen along with BOQ when selecting of panel and acccessories Following provisions to be made in the fire panel
(a) Auto visual alarm & indications having disconnect/rest facility with a range of 1/2 Km. Annuciator to be provided in the fire panel with hooter and sprinkler and acknowlwdge, test and rest PBs. The indication shall come on when electrical driven pump set fails to start on pressure drop or when there is power failure during pressure drop.
(b) Facility for mode selection ie auto or manual test & local/remote.
(c) Protection features & control cabling
(d) Panel shall be interlocked in such a way when fire pump starts on presure drop in the header, supply to working chiller and AC panel disconnected
(e) Remote indication of ON / OFF/ TRIP shall be provided through potential free contact.
(f) Provision of remote starting / stopping (manual) of the engine shall be made
(g) Bus bar shall be provided with heat shrinkable sleeves and shall be colour coded. The panel shall be suitable for cable entry from top. The panel shall be fabricted after the approval of fabrication drawings (all approval through TAC only).
(h) All wire shall be PVC insulated and cable used will be XLPE insulated. 2 Nos earthing terminals shall be provided for 3 phase, 415 V, 50 HZ supply system. M lifting hooks shall also be provided in case of large panels. Cadmium plated harware shall be used in fabrication of panels.
-
-
-
Supply and Fix Bib taps cast copper alloy screwed down fancy type chromium plated, two way type (suitable for health faucet) with crutch or butterfly handle, screwed for iron pipe or for brass ferrule and fixed for 15 mm bore pipe complete all as specified and directed.
102
-
-
Supply and Fix chromium plated wall mixer 15 mm dia for mixing hot and cold water screwed down for iron pipe complete all as specified and directed.
93
-
-
M & L Geo fabric wrapping trench drain to hold aggregates including overlappling complete all as specified and directed.
4287.6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements