Military Engineer Services Tender
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.
Military Engineer Services - MES Tender
Electrical Cables And Wires
Electrical and Electronics
Electrical Works
Eprocure
Opening Date30 Sep 2024
Closing Date21 Oct 2024
Tender Amount₹ 45,00,000
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Comprehensive Repair/maint Of Lt Cable Lt Panel U/g Cables Security Lights Poles And Connected
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_677304_1Bid Award Id
ViewTender No
8648/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning.
90
-
-
Supply and laying un-reinforced precast.concrete cable protection cover of class LV, type-1, flat size 250mm x 150mm x 40 mm, factory made of specified make , complete all as specified and directed.
11
-
-
Supply, installing, testing and commissioning, factory made and tested ,CPRI type tested LT feeder pillar , outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc and consisting of the following:- (a) Aluminium bus bar four Nos 1000 Amps each ,fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 04 Nos, Incoming:- (b) ACB, 04 Pole, 630 Amps with ultimate breaking capacity Icu- 50 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%), Outgoing:- (c) MCCB, 04 Pole, 200 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 03 No (Ics=Icu=100%), (d) MCCB, 04 Pole, 160 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 04 No (Ics=Icu=100%), (e) Spare way for MCCB 200 Amp 4 pole - 01 Nos, (f) Digital type volt meter 0-630 volt with selector switch with HRC fuses/ MCBs - 1Set, (g) Digital type ammeter meter 630 Amp with selector switch with HRC fuses/ MCBs - 1Set. (h) LED phase indication lamps R,Y,B LED type with 3 Nos of 2A HRC Fuses – 1 set, (i) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's, (k) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 mm thick in foundation, brick work in CM 1:6 with sub class B old sized bricks, renderung 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. Note :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel
1
-
-
Supply, installing, testing and commissioning, factory made and tested ,CPRI type tested LT feeder pillar , outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc and consisting of the following:- (a) Aluminium bus bar four Nos 400 Amps each ,fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 04 Nos Incoming:- (b) MCCB, 04 Pole, 250 Amps with ultimate breaking capacity Icu- 50 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%), Outgoing:- (c) MCCB, 04 Pole, 100 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 04 No (Ics=Icu=100%), (d) Spare way for MCCB 100 Amp 4 pole - 01 Nos, (e) Digital type volt meter 0-300 volt with selector switch with HRC fuses/ MCBs - 1Set, (f) Digital type ammeter meter 400 Amp with selector switch with HRC fuses/ MCBs - 1Set, (g) LED phase indication lamps R,Y,B LED type with 3 Nos of 2A HRC Fuses – 1 set, (h) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's/SDFU, (j) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 mm thick in foundation, brick work in CM 1:6 with sub class B old sized bricks, renderung 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. Note :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel
2
-
-
S&F & testing commissioning of outdoor type bus bar panel pedestal type weather proof CPRI approved MS cubical panel board outdoor type of size 110 cm x 80 cm x 40 cm, 4 Nos of bus bar of 300 Amp capacity & MCCB 160 Amp capacity 4 pole (Ics = Icu = 100%) including one coat of red oxide and two coat of enamel paint powder coated, mounted on channels and PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed. The panel shall be fixed over Angle iron frame (50 x 50 mm) of minimum height 75 cm Note :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel
2
-
-
Supply, laying & testing in repalcement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100V grade with stranded aluminium conductor of size 150 sqmm 3.5 core including taking down of old unserviceable UG cable/service wires.
150
-
-
Description all as per item No 09 above but of size 120 Sqmm 3.5 core
250
-
-
Description all as per item No 09 above but of size 95 Sqmm 3.5 core
300
-
-
Description all as per item No 09 above but of size 70 Sqmm 3.5 core
350
-
-
Description all as per item No 09 above but of size 50 Sqmm 3.5 core
350
-
-
Description all as per item No 09 above but of size 35 Sqmm 3.5 core
200
-
-
Description all as per item No 09 above but of size 25 Sqmm 4 core
300
-
-
Description all as per item No 09 above but of size 25 Sqmm 2 core
150
-
-
Description all as per item No 09 above but of size 16 Sqmm 4 core
500
-
-
Supply, laying & testing in repalcement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100V grade with stranded aluminium conductor of size 300 sqmm single core including taking down of old unserviceable UG cable/service wires.
100
-
-
M&L for replacement of new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 60 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including taking down of old unserviceable street light any type/any capacity including replacement of twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from junction box to LED light throgh copper connectos all as specified and directed.
19
-
-
Supply and laying galvanised tube light grade ISI marked of size 40 mm dia incl all fittings in trenches/fixed on pole/wall/floor or laid in position complete all as specified and directed.
15
-
-
M&L for road cutting incl necessary excavation 45 cm wide and 90 cm in depth as in trenches in any type of soils/rock for laying GI/PPR pipe after laying GI pipe trenches will be filled up to road level with 15cm PCC 1:3:6 type C1 using 20mm grade stone aggregate over 15cm 63mm gauge boulders over 15cm 100mm size boulders over rammed/compacted earth all as per specified and directed by Engr-in-Charge.
15
-
-
Supply and laying Double wall corrugated HDPE duct pipe 50mm outer dia confirming to IS: 14930 (Part-II) of approved colour with fittings for cable protection complete laid in trenches or fixed on walls with clamps of suitable size all as specified and directed by Engineer-in-charge.
300
-
-
Supply and laying Double wall corrugated HDPE duct pipe 80mm outer dia confirming to IS: 14930 (Part-II) of approved colour with fittings for cable protection complete laid in trenches or fixed on walls with clamps of suitable size all as specified and directed by Engineer-in-charge.
250
-
-
S & F in replacement of MCCB, 04 Pole, capacity 63 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%) in the existing panel with suitable connecting copper terminals at site complete all specified and directed.
5
-
-
Description all as per item No 24 here in above but of capacity 125 Amps with ultimate breaking capacity 25 KA and ditto-
3
-
-
Description all as per item No 24 here in above but of capacity 160 Amps with ultimate breaking capacity 25 KA and ditto-
3
-
-
Description all as per item No 24 here in above but of capacity 250 Amps with ultimate breaking capacity 35 KA and ditto-
2
-
-
Description all as per item No 24 here in above but of capacity 400 Amps with ultimate breaking capacity 36 KA and ditto-
2
-
-
S & F in replacement of change over switch with advanced neutral, 63 Amps, 4 pole, AC 415 Volt, manual Change over insheet metal enclosure including side operating handle conforming to IS:13947 (Part-3) complete all as specified and directed.
2
-
-
Description all as per item No 29 here in above but of capacity 100 Amps and ditto-
2
-
-
Description all as per item No 29 here in above but of capacity 200 Amps and ditto-
1
-
-
M&L for earthing complete with galvanised steel earth plate electrode 60x60cmx6 mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber ( 1 : 3 : 6) type C1, RCC pit cover , charcol, salt including provision of earth lead protected by 32 mm dia light grade GI pipe and 20 mm dia medium grade GI Pipe for watering complete.
15
-
-