To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Municipal Administration And Urban Development Department Tender

Works
Eprocure
Opening Date21 Dec 2018
Closing Date21 Jan 2019
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Andhra Pradesh Urban Water Supply And Septage Management Improvement Project With Aiib Funding In Prakasam District (package - Ii)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cutting open bituminous tar road surface including depositing of excavated materials for pipe line trench work including labour charges and all incidental and operational charges etc., complete as directed by the Engineer - in - Charge and as per Technical Specification

1505

-

-

... More
RBR-FNDN-1-(i-B-i) : Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH - in Ordinary soil - by Mechanical means

38483

-

-

... More
RBR-FNDN-1-(i-B-i) : Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH - in Ordinary soil by Manual Means

16492.7

-

-

... More
Providing of compacted Sand bed complying with specifications for spreading for pipeline works as directed by the Engineer - in - Charge and as per Technical Specification

7000.7

-

-

... More
Providing of compacted Crusher dust bed complying with specifications for spreading for pipeline works as directed by the Engineer - in - Charge and as per Technical Specification

28003

-

-

... More
Manufacture, Supply and Delivery of HDPE Pipes PN 6.0 PE 100 grade conforming to IS: 4984 - 1995 including transportation to any where in A.P, including transporatation but excuding GST and Taxes etc complete

-

-

-

... More
110mm dia

56990

-

-

... More
160mm dia

128

-

-

... More
180mm dia

2386

-

-

... More
200mm dia

971

-

-

... More
225mm dia

667

-

-

... More
250mm dia

1006

-

-

... More
280mm dia

116

-

-

... More
315mm dia

1295

-

-

... More
355mm dia

818

-

-

... More
Lowering , Laying, Jointing and testing of HDPE pies with minimum water lead of 500m, including all taxes etc complete

-

-

-

... More
110mm dia

56990

-

-

... More
160mm dia

128

-

-

... More
180mm dia

2386

-

-

... More
200mm dia

971

-

-

... More
225mm dia

667

-

-

... More
250mm dia

1006

-

-

... More
280mm dia

116

-

-

... More
315mm dia

1295

-

-

... More
355mm dia

818

-

-

... More
Supply and delivery of PN 1.6 Mpa D.I D/F Butterfly Valves confirming to IS 13095 latest amendment and Material of Construction (as per latest codes) charge of the Tender Document including cost and conveyance and stacking as per standards and as directed by As directed by the Engineer - in - Charge and as per relevent technical specifications but excluding GST

-

-

-

... More
150mm dia

2

-

-

... More
200mm dia

2

-

-

... More
250mm dia

2

-

-

... More
300mm dia

1

-

-

... More
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Seating" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) charge of the Tender Document including cost and conveyance and stacking but excluding GSTas per standards and as directed by As directed by the Engineer - in - Charge and as per relevent technical specifications

-

-

-

... More
100mm dia Sluice valve

45

-

-

... More
100mm dia Scour valve

30

-

-

... More
Labour Charges for lowering and keeping in position of CI sluice valves reflux valves and scour valves dia of valve in mm

-

-

-

... More
100mm dia Sluice valve

45

-

-

... More
150mm dia

2

-

-

... More
200mm dia

2

-

-

... More
250mm dia

2

-

-

... More
300mm dia

1

-

-

... More
100mm dia Scour valve

30

-

-

... More
Jointing the C.I Pipe fittings and valves with flanged ends excluding the cost of jointing materials such as bolts, nuts and white lead but including filling with water with a lead of upto 500m and testing to required pressure etc complete

-

-

-

... More
100mm dia Sluice valve

135

-

-

... More
150mm dia

6

-

-

... More
200mm dia

6

-

-

... More
250mm dia

6

-

-

... More
300mm dia

3

-

-

... More
100mm dia Scour valve

90

-

-

... More
Manufacture, Supply & Delivery of HDPE fittings conforming to IS 4984-1995 including transportation, to anywhere in AP.

-

-

-

... More
110x110x110 - PlainTEE

718

-

-

... More
110 mm dia bends

747

-

-

... More
160x160x160 - Plain TEE

4

-

-

... More
150x100 - Reducer

8

-

-

... More
200x200x200 - Plain TEE

5

-

-

... More
200x100 - Reducer

10

-

-

... More
250x250x250 - Plain TEE

5

-

-

... More
315x315x315 - Plain TEE

5

-

-

... More
300x250 - Reducer

5

-

-

... More
300x100 - Reducer

2

-

-

... More
Manufacture, Supply, delivery, lowering, jointing, laying 300mm dia RCC NP3 class pipes for encasing to Road crossings and Drain crossings and as directed by the Engineer - in - Charge and as per Technical Specifications.

1400

-

-

... More
Construction of sluice and scour Valve Chamber as per type design drawing with CC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work and as directed by the Engineer-in-Charge of the work and as per Technical Specification

-

-

-

... More
100mm dia Sluice valve

75

-

-

... More
150mm dia Sluice valve

2

-

-

... More
200mm diaScour valve

2

-

-

... More
250mm dia

2

-

-

... More
300mm dia

1

-

-

... More
PCC (1:4:8) using 40 mm graded (SS-5) HBG m/c metal and OPC, coarse and fine aggregates conforming to IS:383 including cost & conveyance of all materials, labour charges, machine mixing, laying in position, curing etc. complete for bed and as directed by the Engineer - in - Charge and as per Technical Specifications of Trench Restoration.

1118

-

-

... More
BLD-CSTN-3-11-(28)Using Concrete mixture up to Plinth Level : Plain Cement concrete nominal mix M-30 (Cement : fine aggregate: coarse aggregate ) using 20mm size Hard Granite Machine Crushed Graded Metal including cost and conveyance of all materials like cement, sand, coarse aggregate water etc., to site , seigniorage charges on all materials, labour charges , for mixing , laying, concrete , ramming in 15 cm layers, finishing top surface to the required level curing etc., complete for finished item of work with nomonal reinforcement for Trench Restoration.

1901

-

-

... More
Providing 15mm dia House Service Connection domestic water meters

-

-

-

... More
Providing 15mm dia House Service Connection as per standard specification including the cost of the materials like Clamp Saddle,Ferrule Tapping Saddle confirming to I.S stadard manufactured from virgin resin of PE-80 , Compression Elbows, MDPE PE100 Pipe including lowering, laying and jointing including earth work excavation,UPVC Casing pipe with Two Calmps for drain crossings,Drilling of Holes for RR Masonary and CC Walls , Boring&Tunneling below CC &BT Roads ,saw cutting of groves in CC Roads and refilling the pipe line trench after laying the pipe line and including cost of 15mm dia meter of BIS standard etc complete as directed by departmental officer for finished item of work..( CC Roads and BT Roads should not be distrubed)

-

-

-

... More
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD SIDE (Minimum 4.0 Mts MDPE pipe)

1700

-

-

... More
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD OPPOSITE SIDE IN CC &BT ROADS (Minimum 7.0 Mts MDPE pipe)

680

-

-

... More
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD OPPOSITE SIDE IN EARTHEN ROADS (Minimum 7.0 Mts MDPE pipe)

1020

-

-

... More
Provide installing and giving Satisfactory field testing of battery Operated "B" Class of 15mm size AMR Ultrasonic Meters having no moving part in Contact with water with magnetically sealed coupled and Hermitically sealed register ,with full brass body confirming to ISO 4064 along with manufacturing test certificate with battery life of min.10 years with GSM /RF Technology for communication to server with PC Software including all materials required for fixing ,labour and giving satisfactory leak proof test etc Complete,General Specifications:-1) Meter should be battery operated with no moving parts,low prtesser ,loss,dry type as per FCRI /MID.2)Display:- 8 digit LCD,3)Encloser :-Protection class IP 68 4) Tempature :-Ambit 50deg .C 5) Pressure :-minimum life of 10 Years 7) Memory built -In and should have storage for at least 12 months with daily /monthly accumulated totailised data with time and date should be available .It should able to access memory of the meter through serial communications 8) End Connection:- Screwed up to 40mm BSP/Npt coupling 9) Installation:- Should be able to install in any orientation 10) Transducre :-Inbuilt as per detailed Technical Specifications . 11) The acceptance /routine test shall be either conducted by M/S.Fliud Control Research In stitute ,Palght,Kerala or any of the Laboratories apporved by the National Accerditation Board for Calibration Laboratories (NABL) or EEC pattern apporaval certificates with at least 5 years battery life, including dual channel data loggers ,fixing specials,installation at site etc.. including providing and fixing in position poly propylene water meter box to accommodate water meter all charges and excluding GST and as per Technical Specification

3400

-

-

... More
Supply, deliver and installation of bulk flow meter including consumer meters compatible to SCADA and other instruments in the deliveries for the DMAs of , Govt. Junior College (Zone-2, 1400 KL, ELSR), NSP Office (Zone-3, 1200 KL, ELSR), Market Yard-01 (Zone-4, 400 KL, ELSR), Market Yard-02 (Zone-5, 900 KL, ELSR).

-

-

-

... More
Supply, delivery, installation and integration of Electromagnetic flow meter with IP68 and as per ISO 9001:2008,meter tube should be SS304 material, CS flanges of PN10/PN16 rating liner - hard rubber/polyurethane with WRAS or NSF drinking water approval, electrodes - SS316, 2 measuring electrodes for measuring,1 ground elctrode,1 empty pipe detection, coil housing - SS304 fully welded construction for corrosion grade/painted steel with protective lacquering (corrosive protection, class up to C5-1) as per EN ISO-12944/carbon steel, IP68 protection, Accuracy +/- 0.5% of measured value inclusive of linearity, repeatability etc, grounding rings of SS316/304. Flow transmitter microprocessor based wall mounted, flow ranges of the meter (full flow range). The overall uncertainty of the calibration rig should be atleast three times better than the uncertainty of the full bore electromagnetic flow meter. The competent government authority such as FCRI/NABL must certify the test facility etc. The EMF must be integrated with local SCADA server and the reading shall be captured all times 24x7. The flowmeter values must be persistent and there is no loss of data. The meter shall have display panel for displaying the readings according. This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

-

-

-

... More
350mm dia at Govt. Junior College (Zone-2, 1400 KL, ELSR)

1

-

-

... More
350mm dia NSP Office (Zone-3, 1200 KL, ELSR)

1

-

-

... More
250mm dia Market Yard-01 (Zone-4, 400 KL, ELSR)

1

-

-

... More
300mm dia Market Yard-02 (Zone-5, 900 KL, ELSR)

1

-

-

... More
Supply, delivery , installation of pressure transmitter with a pressure range of up to 16 bar and 64 bar for appropriate usages. Output: 4 to 20 mA, permissible temperature: -20°C to +70°C, IP65 rated with local display. For This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

8

-

-

... More
Supply, delivery , installation of Data Logger with solar powered , battery backup of 5 days including SIM charges for 7 years, transmission rate shall be every 10 minutes cycle that can be configurable from 2 minutes upto 8 hours as needed.This unit shall have additional battery pack to power up ( 5 days backup) for the instruments connected to this item . The data collected from the instruments such as the bulk flow meter , preassure sensors , chlorine etc must be transmitted to the central SCADA Servers via the restfull web services hosted by the servers in the requred data format.

8

-

-

... More
Construction of CC masonry chambers with a openable MS hatch, with lock and key arrangement, steps arrangement, for Electromagnetic Flow meters, Butterfly valves as per pipe sizes including cost of cement, sand, bricks and other required material, including painting and suitable painting material, including labour charges. , Excavation and including wages. Complete as directed by the departmental officer.

-

-

-

1

-

-

1

-

-

2

-

-

... More
Supply, installation , delivery and testing wall mounted ABS plastic enclosure based Online Chlorine Analyzer of Amphreometric or Potentiometric type. Specifications of Range: 0 to 5 mg/L free or total residual chlorine, Resolution 0.01 PPM, Accuracy: +/- 0.05 PPM or better, Cycle Time: 4 minutes, Inlet: Sample Temperature: 5 to 40 °C, operating Temperature: Range 5 to 60 °C. Local LCD Display to display the values. Output: 4-20 mA or 0-10 VDC to integrate into PLC if needed. PH Compensation must be Auto/Manual. All accessories that are required for the must be provided.This item shall include the cost of consumables for the defect liability period of 2 years.

1

-

-

... More
Supply, installation , delivery and testing of wall mounted Turbidity Analyzer make of HACH/ ABB/ Forbes Marshall with specifications of Range 0.00-500.0(NTU/FNU), Operating Temperature : 0 – 60 °C, Displayed Resolution : 0.01 (0.00-19.99), 0.1(20.0-500.0)NTU/FNU, Response Time : Initial response in 1 minute, 15 seconds for a full-scale step change Signal, Sample, Temperature : 0 to 50°C (32 to 122°F), Output 4-20mA to integrate into PLC if needed. Local LCD Display to display the values . This item includes the cost of consumables for the defect liability period of 2 years.

1

-

-

... More
Supply, delivery , installation of Data Logger with solar powered , battery backup of 5 days including SIM charges for 7 years, transmission rate shall be every 10 minutes cycle that can be configurable from 2 minutes upto 8 hours as needed.This unit shall have additional battery pack to power up ( 5 days backup) for the instruments connected to this item . The data collected from the instruments such as the bulk flow meter , preassure sensors , chlorine etc must be transmitted to the central SCADA Servers via the restfull web services hosted by the servers in the requred data format.

1

-

-

... More
Supply delivery and installation of Protection MS grills with lock and key for equipment, instrumentations where ever necessary. This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

1

-

-

... More
Supply , Delivery and installation of manually adjusted preassure reducing valves , accurate pressure ratings. Maximum Upstream Pressure : 20 bar ; Maximum Working Temperature : 80°C. These PRV must be installed at key inlets points of the service reservior.

-

-

-

... More
Govt. Junior College (Zone-2, 1400 KL, ELSR)

-

-

-

3

-

-

2

-

-

1

-

-

... More
NSP Office (Zone-3, 1200 KL, ELSR)

-

-

-

3

-

-

2

-

-

1

-

-

... More
Market Yard-01 (Zone-4, 400 KL, ELSR)

-

-

-

3

-

-

2

-

-

1

-

-

... More
Market Yard-02 (Zone-5, 900 KL, ELSR)

-

-

-

3

-

-

2

-

-

1

-

-

... More
Supply delivery and comissioning the Handheld Devices for meter reading and bill printing. The power back up of this item shall be for 24 hours , android based with on line and offline capabilities, portable credit/debit card machine reader integrated. The connectivity to the central server will be via rest full services with highest security standards , in json data format as directed by the departmental offer. The bill generation , collection shall reflect across the entire system and the acknoledgement of the receipt shall be sent by SMS to the consumer. SIM charges for 7 years shall be provided. This item shall include the cost of consumables for the defect liability period of 2 years.

2

-

-

... More
Control Centre Meter Intergations with server as directed by the Engineer - in - Charge and as per techncial specifications

1

-

-

... More
Supply, testing installation and commissioning of command control: Reputed / Branded Hardware servers (2 nos) with 8GB RAM and 1TB Hard Disk including for operating system server license CentOS/Lunix , Windows OS, key board mouse with 20" LED monitor, Routers, firewall, bill printer , as required for running the software and internet broad band connection with static IP for for 84 months . 2 nos desktop with windows operating system with 8GB RAM and 1TB Hardisk, key board mouse and 20" LED monitor , 3 Nos work station with 3 chairs for each work station , racks for servers , network wiring , power wiring , etc . This item shall, including cost, conveyance , warrenty for 2 years , complete as directed by the departmental officers.

1

-

-

... More
Supply, testing and commissioning of 55" LED monitor with Ethernet/HDMI/VGA/WIFI with waranty for 2 years as directed by the Engineer - in - Charge

1

-

-

... More
Software shall have modules such as Consumer master , grievence , billing , reports , SMS integration , Access log module, online payment module , consumer logins , metering details , dash board , with authentication and authorisation module , issue tracker , accounting and finance module. The soft ware shall expose restfull web services for further/future integrations with other software. The database, web-server shall be open source, license free, portable with all internationally accepted security standards. Authorisation and user access control shall be implemented for the applications mentioned. The application/software shall provide Restful Web Service interface with JSON data format so that it can be integrated to other centralised software and the Android application. All the data received from the instruments and meters shall be stored in database for a period of 4 years and reports shall be retrieved on demand. The data shall be integrated to the SCADA server as directed by the deparmental officer.

1

-

-

... More
Printer - 3 in one on color printer with refillable ink bank as directed by the Engineer - in - Charge

1

-

-

... More
Supply, Delivery and Installation of 1600VA UPS with solar panels, battery enclosures with doors along with racks, to provide 40 hours battery backup calculated at 50% load. The solar panels should to charge the battery to full capacity in 7 hours of sunshine. As per relevant specification amended time to time for single phase input with input circuit breakers provided protection, sine wave from with sealed battery, maintenance free, recharge time conform to standards. The Batteries shall be of VLRA Type. This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

1

-

-

... More
Provision for Environmental Mitigation Measures

-

-

-

... More
Construction Phase (Two years)

-

-

-

... More
Air Quality Monitoring ( 5 Monitoring station) once in a month for three seasons during the construction period at Intake well, GLBR,WTP, ELSRs & Raw & clear water pipe lines and distribution network.

10

-

-

... More
Noise level Monitoring ( 5 Monitoring station) once in a month for three seasons during the construction period at Intake well, GLBR,WTP, ELSRs & Raw & clear water pipe lines and distribution network.

10

-

-

... More
Water Quality Monitoring surface / ground (6 Monitoring station) once in a month for three seasons during the construction period at Intake well, GLBR,WTP, ELSRs & Raw & clear water pipe lines and distribution network.

15

-

-

... More
Compensatory plantation and three years maintenance (Compensatory afforestation ratio is 1:5).

125

-

-

... More
Sprinkling of water with 4000 Litres capacity tankers once in a day excluding rainy days as directed by the Engineer - in - Charge

450

-

-

... More
Chimakurthy Nagara Panchayat (CAPEX)

-

-

-

... More
Laying of HDPE Distribution Lines 71448 Rmt in Chimakurthy Nagara Panchayat

-

-

-

... More
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means. (RBR-FNDN-1 (I B i).

-

-

-

... More
in ordinary soils by Machenical means

30650

-

-

... More
in ordinary soils by Manual means

12260

-

-

... More
in Ordinary rock (not requiring blasting) by Manual means upto 3.00m depth

6130

-

-

... More
in Ordinary rock (not requiring blasting) by Machenical means upto 3.00m depth

12260

-

-

... More
Providing bedding with sand for pipelines trencehs as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification and directed by the Engineer - in - Charge

4850

-

-

... More
Manufacture, Supply and Delivery of HDPE Pipes PN 6.0 PE 100 grade conforming to IS: 4984 - 1995 including transportation to any where in A.P, including transporatation but excuding GST and Taxes etc complete

-

-

-

... More
HDPE pipes PE 100- PN 6

-

-

-

... More
110mm dia.

42122

-

-

... More
160mm dia.

11455

-

-

... More
200mm dia.

8852

-

-

... More
250mm dia.

4837

-

-

... More
315 mm dia.

3407

-

-

... More
355 mm dia.

775

-

-

... More
Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete as per detailed specification and directed by the Engineer - in - Charge

-

-

-

... More
a) Pipe ends - long neck

-

-

-

... More
110mm dia.

168

-

-

... More
160mm dia.

94

-

-

... More
200mm dia.

60

-

-

... More
250mm dia.

36

-

-

... More
315 mm dia.

28

-

-

... More
355 mm dia

14

-

-

... More
b) MS Flanges

-

-

-

... More
110mm dia.

168

-

-

... More
160mm dia.

94

-

-

... More
200mm dia.

60

-

-

... More
250mm dia.

36

-

-

... More
315 mm dia.

28

-

-

... More
355 mm dia

14

-

-

... More
c) End Caps

-

-

-

... More
110mm dia.

21

-

-

... More
160mm dia.

5

-

-

... More
200mm dia.

4

-

-

... More
d) Reducers

-

-

-

... More
110X125 mm dia

58

-

-

... More
125x140 mm dia

58

-

-

... More
140x160 mm dia

58

-

-

... More
160x180 mm dia

24

-

-

... More
180x200 mm dia

24

-

-

... More
200x225 mm dia

23

-

-

... More
225x250 mm dia

23

-

-

... More
250x280 mm dia

23

-

-

... More
280x315 mm dia

23

-

-

... More
315x355 mm dia

5

-

-

... More
e) TEES

-

-

-

... More
110mm dia.

169

-

-

... More
160mm dia.

47

-

-

... More
200mm dia.

37

-

-

... More
250mm dia.

19

-

-

... More
315 mm dia.

14

-

-

... More
355 mm dia

4

-

-

... More
F) Bends

-

-

-

... More
110mm dia.

84

-

-

... More
160mm dia.

24

-

-

... More
200mm dia.

18

-

-

... More
250mm dia.

10

-

-

... More
315 mm dia.

7

-

-

... More
355 mm dia

1

-

-

... More
Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc., complete as per detailed specification and directed by the Engineer - in - Charge

-

-

-

... More
110mm dia.

42122

-

-

... More
160mm dia.

11455

-

-

... More
200mm dia.

8852

-

-

... More
250mm dia.

4837

-

-

... More
315 mm dia.

3407

-

-

... More
355 mm dia.

775

-

-

... More
Supply and delivery of DI Pipes and fittings (Specials) confirming to specification No.I.S.No. 9523 -2000 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities.

-

-

-

... More
DI D/F pipes for scours

-

-

-

... More
100X2.00m on 110 dia mains for scours

28

-

-

... More
100X2.00m on 160 dia mains for scours

10

-

-

... More
100x1.00m long DF pipes for sluice valves

172

-

-

... More
150X2.00m on 200 mm dia mains for scours

6

-

-

... More
150X2.00m on 250 mm dia mains for scours

4

-

-

... More
150x1.00m long DF pipes for sluice valves

46

-

-

... More
200x1.00m long DF pipes for sluice valves

36

-

-

... More
250x1.00m long DF pipes for sluice valves

24

-

-

... More
300x1.00m long DF pipes for sluice valves

18

-

-

... More
350x1.00m long DF pipes for sluice valves

8

-

-

... More
DI fittings and specials

3200

-

-

... More
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Seating" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) charge of the Tender Document including cost and conveyance and stacking but excluding GST as per standards and as directed by As directed by the Engineer - in - Charge and as per relevent technical specifications

-

-

-

... More
100 mm distrubution

84

-

-

... More
150mm dia for distrubution

23

-

-

... More
200mm dia for distrubution

18

-

-

... More
250mm dia for distrubution

12

-

-

... More
300mm dia for distrubution

9

-

-

... More
350mm dia for distrubution

4

-

-

... More
for scour

-

-

-

... More
100mm dia on 110 mm dia mains

14

-

-

... More
100mm dia on 160 mm dia mains

5

-

-

... More
150 mm dia on 200 mm dia lines

3

-

-

... More
150 mm dia on 250 mm dia lines

2

-

-

... More
80mm dia for isolation

43

-

-

... More
Manufacture, supply and delivery of 80 mm dia Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S.14845 and subsequent revisions. All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538 excluding GST - PN16 -80 mm dia

43

-

-

... More
Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valve complete as per detailed specification and directed by the Engineer - in - Charge

-

-

-

... More
100 mm distrubution

84

-

-

... More
150mm dia for distrubution

23

-

-

... More
200mm dia for distrubution

19

-

-

... More
250mm dia for distrubution

12

-

-

... More
300mm dia for distrubution

9

-

-

... More
350mm dia for distrubution

5

-

-

... More
for scour

-

-

-

... More
100mm dia on 110 mm dia mains

14

-

-

... More
100mm dia on 160 mm dia mains

5

-

-

... More
150 mm dia on 200 mm dia lines

3

-

-

... More
300mm dia for distrubution

2

-

-

... More
Labour charges for fixing of 80 mm dia Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per detailed specification and directed by the Engineer - in - Charge -80 mm dia

43

-

-

... More
Construction of sluice and scour Valve Chamber as per type design drawing with CC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work and as directed by the Engineer-in-Charge of the work and as per Technical Specification

-

-

-

... More
100 mm distrubution

84

-

-

... More
150mm dia for distrubution

24

-

-

... More
200mm dia for distrubution

18

-

-

... More
250mm dia for distrubution

13

-

-

... More
300mm dia for distrubution

9

-

-

... More
350mm dia for distrubution

4

-

-

... More
for scour

-

-

-

... More
100mm dia on 110 mm dia mains

14

-

-

... More
100mm dia on 160 mm dia mains

5

-

-

... More
150 mm dia on 200 mm dia lines

3

-

-

... More
150 mm dia on 250 mm dia lines

2

-

-

... More
Construction of Air Valve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work

-

-

-

... More
80 mm dia on 160 mm pipe

17

-

-

... More
80 mm dia on 200 mm pipe

12

-

-

... More
80mm dia 250 mm pipe

6

-

-

... More
80mm dia 315 mm pipe

5

-

-

... More
80mm dia 355 mm pipe

3

-

-

... More
Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94 complete as per detailed specification and directed by the Engineer - in - Charge

-

-

-

... More
DI D/F pipes for scours

-

-

-

... More
100 mm

267

-

-

... More
150 mm dia

90

-

-

... More
200 mm dia

48

-

-

... More
250 mm dia

30

-

-

... More
300 mm dia

23

-

-

... More
350 mm dia

11

-

-

... More
Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 complete as per detailed specification and directed by the Engineer - in - Charge

-

-

-

... More
80 mm dia

43

-

-

... More
100 mm dia

436

-

-

... More
150 mm dia

237

-

-

... More
200 mm dia

122

-

-

... More
250 mm dia

72

-

-

... More
300 mm dia

62

-

-

... More
350 mm dia

11

-

-

... More
Cutting BT road surface as well as asphalt (75mm thick) including water bound. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work.

9570

-

-

... More
Cutting the CC road surface. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work.

2870

-

-

... More
Cutting the open water bound macadam. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work.

10020

-

-

... More
Filling crusher stone dust in pipe line trenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH complete as per detailed specification and directed by the Engineer - in - Charge

34720

-

-

... More
Using Concrete mixture up to Plinth Level : Plain Cement concrete nominal mix M-30 (Cement : fine aggregate: coarse aggregate ) using 20mm size Hard Granite Machine Crushed Graded Metal including cost and conveyance of all materials like cement, sand, coarse aggregate water etc., to site , seigniorage charges on all materials, labour charges , for mixing , laying, concrete , ramming in 15 cm layers, finishing top surface to the required level curing etc., complete for finished item of work with nomonal reinforcement for Road restoration. for BT&CC roads etc., complete as per detailed specification and directed by the Engineer - in - Charge

4175

-

-

... More
Providing 15mm dia 4190 Nos New House service connections

-

-

-

... More
Providing 15mm dia House Service Connection as per standard specification including the cost of the materials like Clamp Saddle,Ferrule Tapping Saddle confirming to I.S stadard manufactured from virgin resin of PE-80 , Compression Elbows, MDPE PE100 Pipe including lowering, laying and jointing including earth work excavation,UPVC Casing pipe with Two Calmps for drain crossings,Drilling of Holes for RR Masonary and CC Walls , Boring&Tunneling below CC &BT Roads ,saw cutting of groves in CC Roads and refilling the pipe line trench after laying the pipe line and including cost of 15mm dia meter of BIS standard etc complete as directed by departmental officer for finished item of work..( CC Roads and BT Roads should not be distrubed)

-

-

-

... More
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD SIDE (Minimum 4.0 Mts MDPE pipe)

2095

-

-

... More
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD OPPOSITE SIDE IN EARTHEN ROADS (Minimum 7.0 Mts MDPE pipe)

1257

-

-

... More
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD OPPOSITE SIDE IN CC &BT ROADS (Minimum 7.0 Mts MDPE pipe)

838

-

-

... More
AMR Ultrasonic Meters

-

-

-

... More
Provide installing and giving Satisfactory field testing of battery Operated "B" Class AMR Ultrasonic Meters having no moving part in Contact with water with magnetically sealed coupled and Hermitically sealed register ,with full brass body confirming to ISO 4064 along with manufacturing test certificate with battery life of min.10 years with GSM /RF Technology for communication to server with PC Software including all materials required for fixing ,labour and giving satisfactory leak proof test etc Complete,General Specifications:-1) Meter should be battery operated with no moving parts,low prtesser ,loss,dry type as per FCRI /MID.2)Display:- 8 digit LCD,3)Encloser :-Protection class IP 68 4) Tempature :-Ambit 50deg .C 5) Pressure :-minimum life of 10 Years 7) Memory built -In and should have storage for at least 12 months with daily /monthly accumulated totailised data with time and date should be available .It should able to access memory of the meter through serial communications 8) End Connection:- Screwed up to 40mm BSP/Npt coupling 9) Installation:- Should be able to install in any orientation 10) Transducre :-Inbuilt as per detailed Technical Specifications . 11) The acceptance /routine test shall be either conducted by M/S.Fliud Control Research In stitute ,Palght,Kerala or any of the Laboratories apporved by the National Accerditation Board for Calibration Laboratories (NABL) or EEC pattern apporaval certificates with at least 5 years battery life, including dual channel data loggers ,fixing specials,installation at site etc.. including providing and fixing in position poly propylene water meter box to accommodate water meter all charges and excluding GST and as per technical specifications

4190

-

-

... More
Supply, deliver and installation of bulk flow meter including consumer meters and other instruments in the deliveries for the DMAs

-

-

-

... More
MRO Office (Zone-1, 1500 KL, ELSR, 350mm), MRO Office (Zone-2, 250 KL, ELSR, 150mm), Govt. College & Junior College (Zone-3, 1000 KL, ELSR, 250mm), NSP Colony (Zone-4, 200 KL, ELSR, 150mm).

-

-

-

... More
Supply, delivery, installation and integration of Electromagnetic flow meter with IP68 and as per ISO 9001:2008,meter tube should be SS304 material, CS flanges of PN10/PN16 rating liner - hard rubber/polyurethane with WRAS or NSF drinking water approval, electrodes - SS316, 2 measuring electrodes for measuring,1 ground elctrode,1 empty pipe detection, coil housing - SS304 fully welded construction for corrosion grade/painted steel with protective lacquering (corrosive protection, class up to C5-1) as per EN ISO-12944/carbon steel, IP68 protection, Accuracy +/- 0.5% of measured value inclusive of linearity, repeatability etc, grounding rings of SS316/304. Flow transmitter microprocessor based wall mounted, flow ranges of the meter (full flow range). The overall uncertainty of the calibration rig should be atleast three times better than the uncertainty of the full bore electromagnetic flow meter. The competent government authority such as FCRI/NABL must certify the test facility etc. The EMF must be integrated with local SCADA server and the reading shall be captured all times 24x7. The flowmeter values must be persistent and there is no loss of data. The meter shall have display panel for displaying the readings according. This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

-

-

-

... More
350mm dia at MRO Office (Zone-1, 1500 KL, ELSR 350 Ø)

1

-

-

... More
150mm dia at MRO Office (Zone-2, 250 KL, ELSR 150 Ø)

1

-

-

... More
350mm dia at Govt. College & Junior College (Zone-3, 1000 KL, ELSR 350 Ø)

1

-

-

... More
200mm dia at NSP Colony (Zone-4, 200 KL, ELSR 200 Ø)

1

-

-

... More
Supply, delivery , installation of pressure transmitter with a pressure range of up to 16 bar and 64 bar for appropriate usages. Output: 4 to 20 mA, permissible temperature: -20°C to +70°C, IP65 rated with local display. For This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

8

-

-

... More
Supply, delivery , installation of Data Logger with solar powered , battery backup of 5 days including SIM charges for 7 years, transmission rate shall be every 10 minutes cycle that can be configurable from 2 minutes upto 8 hours as needed.This unit shall have additional battery pack to power up ( 5 days backup) for the instruments connected to this item . The data collected from the instruments such as the bulk flow meter , preassure sensors , chlorine etc must be transmitted to the central SCADA Servers via the restfull web services hosted by the servers in the requred data format.

8

-

-

... More
Construction of CC masonry chambers with a openable MS hatch, with lock and key arrangement, steps arrangement, for Electromagnetic Flow meters, Butterfly valves as per pipe sizes including cost of cement, sand, bricks and other required material, including painting and suitable painting material, including labour charges. , Excavation and including wages. Complete as directed by the departmental officer.

-

-

-

1

-

-

... More
350mm

2

-

-

... More
Supply delivery and installation of Protection MS grills with lock and key for equipment, instrumentations where ever necessary. This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

1

-

-

... More
Supply, installation , delivery and testing wall mounted ABS plastic enclosure based Online Chlorine Analyzer of Amphreometric or Potentiometric type. Specifications of Range: 0 to 5 mg/L free or total residual chlorine, Resolution 0.01 PPM, Accuracy: +/- 0.05 PPM or better, Cycle Time: 4 minutes, Inlet: Sample Temperature: 5 to 40 °C, operating Temperature: Range 5 to 60 °C. Local LCD Display to display the values. Output: 4-20 mA or 0-10 VDC to integrate into PLC if needed. PH Compensation must be Auto/Manual. All accessories that are required for the must be provided.This item shall include the cost of consumables for the defect liability period of 2 years.

1

-

-

... More
Supply, installation , delivery and testing of wall mounted Turbidity Analyzer make of HACH/ ABB/ Forbes Marshall with specifications of Range 0.00-500.0(NTU/FNU), Operating Temperature : 0 – 60 °C, Displayed Resolution : 0.01 (0.00-19.99), 0.1(20.0-500.0)NTU/FNU, Response Time : Initial response in 1 minute, 15 seconds for a full-scale step change Signal, Sample, Temperature : 0 to 50°C (32 to 122°F), Output 4-20mA to integrate into PLC if needed. Local LCD Display to display the values . This item includes the cost of consumables for the defect liability period of 2 years.

1

-

-

... More
Supply, delivery , installation of Data Logger with solar powered , battery backup of 5 days including SIM charges for 7 years, transmission rate shall be every 10 minutes cycle that can be configurable from 2 minutes upto 8 hours as needed.This unit shall have additional battery pack to power up ( 5 days backup) for the instruments connected to this item . The data collected from the instruments such as the bulk flow meter , preassure sensors , chlorine etc must be transmitted to the central SCADA Servers via the restfull web services hosted by the servers in the requred data format.

1

-

-

... More
Supply delivery and installation of Protection MS grills with lock and key for equipment, instrumentations where ever necessary. This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

1

-

-

... More
Supply , Delivery and installation of manually adjusted preassure reducing valves , accurate pressure ratings. Maximum Upstream Pressure : 20 bar ; Maximum Working Temperature : 80°C. These PRV must be installed at key inlets points of the service reservior.

-

-

-

... More
100mm at MRO Office (Zone-1, 1500 KL, ELSR 350 Ø)

2

-

-

... More
100mm dia at MRO Office (Zone-2, 250 KL, ELSR 150 Ø)

2

-

-

... More
100mm dia at Govt. College & Junior College (Zone-3, 1000 KL, ELSR 350 Ø)

2

-

-

... More
100mm dia at NSP Colony (Zone-4, 200 KL, ELSR 200 Ø)

2

-

-

... More
Supply delivery and comissioning the Handheld Devices for meter reading and bill printing. The power back up of this item shall be for 24 hours , android based with on line and offline capabilities, portable credit/debit card machine reader integrated. The connectivity to the central server will be via rest full services with highest security standards , in json data format as directed by the departmental offer. The bill generation , collection shall reflect across the entire system and the acknoledgement of the receipt shall be sent by SMS to the consumer. SIM charges for 7 years shall be provided. This item shall include the cost of consumables for the defect liability period of 2 years.

5

-

-

... More
Meter Intergations with server Control Centre as directed by the Engineer - in - Charge

1

-

-

... More
Supply, testing installation and commissioning of command control: Reputed / Branded Hardware servers (2 nos) with 8GB RAM and 1TB Hard Disk including for operating system server license CentOS/Lunix , Windows OS, key board mouse with 20" LED monitor, Routers, firewall, bill printer , as required for running the software and internet broad band connection with static IP for for 84 months . 2 nos desktop with windows operating system with 8GB RAM and 1TB Hardisk, key board mouse and 20" LED monitor , 3 Nos work station with 3 chairs for each work station , racks for servers , network wiring , power wiring , etc . This item shall, including cost, conveyance , warrenty for 2 years , complete as directed by the departmental officers.

1

-

-

... More
Supply, testing and commissioning of 55" LED monitor with Ethernet/HDMI/ VGA/WIFI with waranty for 2 years as directed by the Engineer - in - Charge

1

-

-

... More
Software shall have modules such as Consumer master , grievence , billing , reports , SMS integration , Access log module, online payment module , consumer logins , metering details , dash board , with authentication and authorisation module , issue tracker , accounting and finance module. The soft ware shall expose restfull web services for further/future integrations with other software. The database, web-server shall be open source, license free, portable with all internationally accepted security standards. Authorisation and user access control shall be implemented for the applications mentioned. The application/software shall provide Restful Web Service interface with JSON data format so that it can be integrated to other centralised software and the Android application. All the data received from the instruments and meters shall be stored in database for a period of 4 years and reports shall be retrieved on demand. The data shall be integrated to the SCADA server as directed by the deparmental officer.

1

-

-

... More
Printer - 3 in one on color printer with refillable ink bank as directed by the Engineer - in - Charge

1

-

-

... More
Supply, Delivery and Installation of 1600VA UPS with solar panels, battery enclosures with doors along with racks, to provide 40 hours battery backup calculated at 50% load. The solar panels should to charge the battery to full capacity in 7 hours of sunshine. As per relevant specification amended time to time for single phase input with input circuit breakers provided protection, sine wave from with sealed battery, maintenance free, recharge time conform to standards. The Batteries shall be of VLRA Type. This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

1

-

-

... More
Implementation of Environmental Management plan in Chimakurthy Nagara Panchayat

-

-

-

... More
Air Quality Monitoring (4 Monitoring station) once in a month for three seasons during the construction period at Distribution network

16

-

-

... More
Noise level (4 Monitoring station) once in a month for three seasons during the construction period at Distribution network

16

-

-

... More
Water Quality Monitoring surface / ground (4 Monitoring station) once in a month for three seasons during the construction period at Distribution network

23

-

-

... More
Compensatory plantation and three years maintenance (Compensatory afforestation ratio is 1:5)-plants & tree guards

54

-

-

... More
Sprinkling of water with 5000 Litres capacity tankers once in a day excluding rainy days as directed by the Engineer - in - Charge

600

-

-

... More
Hiring for 1 No Vehicles for 24 Months during Construction Period including hire charges of vehicle, diesel, lubrication, driver charges, repairs and all incidental charges etc.,

24

-

-

... More
GIDDALURU NAGARA PANCHAYAT(CAPEX)

-

-

-

... More
Bill no 1:Providing of Distribution system in Zone - 1,2,3,4,5,6 & 7 for a Length of 103438.00mts including Trench Restoration.

-

-

-

... More
Cutting BT road surface as well as asphalt (75mm thick) including water bound. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work.

3660

-

-

... More
Cutting the CC road surface. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work.

1050

-

-

... More
Cutting the open water bound macadam. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work.

2200

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trench in ordinary soils by Manual Means unit 1.00 cum RBR-FNDN-1 I-A

18580

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH upto 3.00m depth in Ordinary Soils by Mechanical Means RBR-FNDN-1 I-B

27870

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH in Ordinary Rock (not required blasting) by Manual Means upto 3.00m depth RBR-FNDN-1 II-A

18580

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH in Ordinary Rock (not required blasting) by Mechanical Means upto 3.00m depth RBR-FNDN-1 II-B

27870

-

-

... More
Providing bedding with sand for pipelines trencehs as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification and directed by the Engineer - in - Charge

7270

-

-

... More
Manufacture, Supply and Delivery of HDPE Pipes PN 6.0 PE 100 grade conforming to IS: 4984 - 1995 including transportation to any where in A.P, including transporatation but excuding GST and Taxes etc complete

-

-

-

... More
110mm dia.

47700

-

-

... More
160mm dia.

22051

-

-

... More
200mm dia.

17205

-

-

... More
250mm dia.

10758

-

-

... More
315 mm dia.

4109

-

-

... More
355 mm dia.

1615

-

-

... More
Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete

-

-

-

... More
110mm dia.

47700

-

-

... More
160mm dia.

22051

-

-

... More
200mm dia.

17205

-

-

... More
250mm dia.

10758

-

-

... More
315 mm dia.

4109

-

-

... More
355 mm dia.

1615

-

-

... More
Manufacture, supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to work spot, stacking excluding all taxes and duties etc.complete

-

-

-

-

-

-

... More
110mm dia.

190

-

-

... More
160mm dia.

88

-

-

... More
200mm dia.

69

-

-

... More
250mm dia.

42

-

-

... More
315 mm dia.

16

-

-

... More
355 mm dia

6

-

-

-

-

-

... More
110mm dia.

95

-

-

... More
160mm dia.

43

-

-

... More
200mm dia.

34

-

-

... More
250mm dia.

21

-

-

... More
315 mm dia.

8

-

-

... More
355 mm dia

3

-

-

... More
END CAPS

-

-

-

... More
110mm dia.

24

-

-

... More
160mm dia.

12

-

-

... More
200mm dia.

9

-

-

... More
REDUCERS

-

-

-

... More
OD 110mm x 125mm

110

-

-

... More
OD 125mm x 140mm

110

-

-

... More
OD 140mm x 160mm

110

-

-

... More
OD 160mm x 180mm

29

-

-

... More
OD 180mm x 200mm

29

-

-

... More
OD 200mm x 225mm

29

-

-

... More
OD 225mm x 250mm

29

-

-

... More
250x280 mm dia

29

-

-

... More
280x315 mm dia

29

-

-

... More
315x355 mm dia

11

-

-

... More
a) Pipe ends - long neck

-

-

-

... More
110mm dia.

158

-

-

... More
160mm dia.

170

-

-

... More
200mm dia.

102

-

-

... More
250mm dia.

84

-

-

... More
315 mm dia.

40

-

-

... More
355 mm dia

24

-

-

... More
b) MS Flanges

-

-

-

... More
110mm dia.

158

-

-

... More
160mm dia.

170

-

-

... More
200mm dia.

102

-

-

... More
250mm dia.

84

-

-

... More
315 mm dia.

40

-

-

... More
355 mm dia

24

-

-

... More
Supply and delivery of DI Pipes and fittings (Specials) confirming to specification No.I.S.No.9523 - 2000 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities.

-

-

-

... More
DI D/F pipes for scours

-

-

-

... More
100X2.00m on 110 dia mains for scours

30

-

-

... More
100X2.00m on 160 dia mains for scours

14

-

-

... More
100x1.00m long DF pipes for sluice valves

158

-

-

... More
150X2.00m on 200 mm dia mains for scours

10

-

-

... More
150X2.00m on 250 mm dia mains for scours

6

-

-

... More
150x1.00m long DF pipes for sluice valves

72

-

-

... More
150x1.00m long DF pipes for pressure regulating valves

26

-

-

... More
150x1.00m long DF pipes for bulk flow meter

2

-

-

... More
200x1.00m long DF pipes for sluice valves

58

-

-

... More
250x1.00m long DF pipes for sluice valves

54

-

-

... More
250x1.00m long DF pipes for bulk flow meter

2

-

-

... More
300x1.00m long DF pipes for sluice valves

28

-

-

... More
350x1.00m long DF pipes for sluice valves

14

-

-

... More
350x1.00m long DF pipes for bulk flow meter

8

-

-

... More
DI fittings and specials

4900

-

-

... More
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Seating" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) charge of the Tender Document including cost and conveyance and stacking but excliding GST as per standards and as directed by As directed by the Engineer - in - Charge and as per relevent technical specifications

-

-

-

... More
100 mm dia for distrubution

79

-

-

... More
150mm dia for distrubution

36

-

-

... More
200mm dia for distrubution

29

-

-

... More
250mm dia for distrubution

27

-

-

... More
300mm dia for distrubution

14

-

-

... More
350mm dia for distrubution

6

-

-

... More
for scour

-

-

-

... More
100mm dia on 110 mm dia mains

15

-

-

... More
100mm dia on 160 mm dia mains

7

-

-

... More
150 mm dia on 200 mm dia lines

5

-

-

... More
150 mm dia on 250 mm dia lines

3

-

-

... More
80mm dia for isolation

78

-

-

... More
Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S.14845 and subsequent revisions. All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538 but exclding GST--. PN16

-

-

-

... More
80 mm dia

78

-

-

... More
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification

-

-

-

... More
100 mm distrubution

79

-

-

... More
150mm dia for distrubution

37

-

-

... More
200mm dia for distrubution

29

-

-

... More
250mm dia for distrubution

28

-

-

... More
300mm dia for distrubution

14

-

-

... More
300 mm dia for bulk flow meter

1

-

-

... More
350mm dia for distrubution

6

-

-

... More
350 mm dia for bulk flow meter

4

-

-

... More
for scour

-

-

-

... More
100mm dia on 110 mm dia mains

14

-

-

... More
100mm dia on 160 mm dia mains

8

-

-

... More
150 mm dia on 200 mm dia lines

5

-

-

... More
150 mm dia on 250 mm dia lines

3

-

-

... More
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete.

-

-

-

... More
80 mm dia on 150,250,315,355 and 400 mm pipes

78

-

-

... More
Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94.

-

-

-

... More
DIDF pipes for scours

-

-

-

... More
100 mm

268

-

-

... More
150 mm dia

175

-

-

... More
200 mm dia

80

-

-

... More
250 mm dia

70

-

-

... More
300 mm dia

35

-

-

... More
350 mm dia

24

-

-

... More
Jointing CI pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete and as per Technical Specification

-

-

-

... More
80 mm dia

78

-

-

... More
100 mm dia

439

-

-

... More
150 mm dia

411

-

-

... More
200 mm dia

204

-

-

... More
250 mm dia

166

-

-

... More
300 mm dia

86

-

-

... More
350 mm dia

24

-

-

... More
Construction of sluice and scour Valve Chamber as per type design drawing with CC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work and as directed by the Engineer-in-Charge of the work and as per Technical Specification

-

-

-

... More
100 mm dia for distrubution

79

-

-

... More
150mm dia for distrubution

37

-

-

... More
200mm dia for distrubution

29

-

-

... More
250mm dia for distrubution

28

-

-

... More
300mm dia for distrubution

14

-

-

... More
300mm dia for bulk flow meter

1

-

-

... More
350mm dia for distrubution

6

-

-

... More
350mm dia for bulk flow meter

4

-

-

... More
for scour

-

-

-

... More
100mm dia on 110 mm dia mains

14

-

-

... More
100mm dia on 160 mm dia mains

7

-

-

... More
150 mm dia on 200 mm dia lines

6

-

-

... More
150 mm dia on 250 mm dia lines

3

-

-

... More
Construction of Air Valve Chamber as per type design drawing with RCC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work

-

-

-

... More
80 mm dia on 160 mm pipe

35

-

-

... More
80 mm dia on 200 mm pipe

22

-

-

... More
80mm dia 250 mm pipe

14

-

-

... More
80mm dia 315 mm pipe

5

-

-

... More
80mm dia 355 mm pipe

2

-

-

... More
Trench Restoration

-

-

-

... More
Filling crusher stone dust in pipe line trenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH

2210

-

-

... More
Using Concrete mixture up to Plinth Level : Plain Cement concrete nominal mix M-30 (Cement : fine aggregate: coarse aggregate ) using 20mm size Hard Granite Machine Crushed Graded Metal including cost and conveyance of all materials like cement, sand, coarse aggregate water etc., to site , seigniorage charges on all materials, labour charges , for mixing , laying, concrete , ramming in 15 cm layers, finishing top surface to the required level curing etc., complete for finished item of work with nomonal reinforcement for BT&CC roads

1518

-

-

... More
Providing House Service Connections (shifing of existing HSCs and providing new HSCs)

-

-

-

... More
Providing 15mm dia House Service Connection as per standard specification including the cost of the materials like Clamp Saddle,Ferrule Tapping Saddle confirming to I.S stadard manufactured from virgin resin of PE-80 , Compression Elbows, MDPE PE100 Pipe including lowering, laying and jointing including earth work excavation,UPVC Casing pipe with Two Calmps for drain crossings,Drilling of Holes for RR Masonary and CC Walls , Boring&Tunneling below CC &BT Roads ,saw cutting of groves in CC Roads and refilling the pipe line trench after laying the pipe line and including cost of 15mm dia meter of BIS standard etc complete as directed by departmental officer for finished item of work..( CC Roads and BT Roads should not be distrubed)

-

-

-

... More
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD SIDE (Minimum 4.0 Mts MDPE pipe)

2512

-

-

... More
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD OPPOSITE SIDE IN EARTHEN ROADS (Minimum 7.0 Mts MDPE pipe)

1507

-

-

... More
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD OPPOSITE SIDE IN CC &BT ROADS (Minimum 7.0 Mts MDPE pipe)

1004

-

-

... More
Bill No: 8 AMR Ultrasonic Meters

-

-

-

... More
Provide installing and giving Satisfactory field testing of battery Operated "B" Class AMR Ultrasonic Meters having no moving part in Contact with water with magnetically sealed coupled and Hermitically sealed register ,with full brass body confirming to ISO 4064 along with manufacturing test certificate with battery life of min.10 years with GSM /RF Technology for communication to server with PC Software including all materials required for fixing ,labour and giving satisfactory leak proof test etc Complete,General Specifications:-1) Meter should be battery operated with no moving parts,low prtesser ,loss,dry type as per FCRI /MID.2)Display:- 8 digit LCD,3)Encloser :-Protection class IP 68 4) Tempature :-Ambit 50deg .C 5) Pressure :-minimum life of 10 Years 7) Memory built -In and should have storage for at least 12 months with daily /monthly accumulated totailised data with time and date should be available .It should able to access memory of the meter through serial communications 8) End Connection:- Screwed up to 40mm BSP/Npt coupling 9) Installation:- Should be able to install in any orientation 10) Transducre :-Inbuilt as per detailed Technical Specifications . 11) The acceptance /routine test shall be either conducted by M/S.Fliud Control Research In stitute ,Palght,Kerala or any of the Laboratories apporved by the National Accerditation Board for Calibration Laboratories (NABL) or EEC pattern apporaval certificates with at least 5 years battery life, including dual channel data loggers ,fixing specials,installation at site etc.. including providing and fixing in position poly propylene water meter box to accommodate water meter all charges and excluding GST

5023

-

-

... More
Supply, deliver and installation of bulk flow meter and other instruments in the deliveries for the DMAs of

-

-

-

... More
Supply, delivery, installation and integration of Electromagnetic flow meter with IP68 and as per ISO 9001:2008,meter tube should be SS304 material, CS flanges of PN16 rating liner - hard rubber/polyurethane with WRAS or NSF drinking water approval, electrodes - SS316, 2 measuring electrodes for measuring,1 ground elctrode,1 empty pipe detection, coil housing - SS304 fully welded construction for corrosion grade/painted steel with protective lacquering (corrosive protection, class up to C5-1) as per EN ISO-12944/carbon steel, IP68 protection, Accuracy +/- 0.5% of measured value inclusive of linearity, repeatability etc, grounding rings of SS316/304. Flow transmitter microprocessor based wall mounted, flow ranges of the meter (full flow range). The overall uncertainty of the calibration rig should be atleast three times better than the uncertainty of the full bore electromagnetic flow meter. The competent government authority such as FCRI/NABL must certify the test facility etc. The EMF must be integrated with local SCADA server and the reading shall be captured all times 24x7. The flowmeter values must be persistent and there is no loss of data. The meter shall have display panel for displaying the readings according. This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

-

-

-

... More
350mm dia Lakshmi Narasimha Swamy Temple (Zone-1, 700 KL, ELSR, 355 )

1

-

-

... More
350mm dia at Lakshmi Narasimha Swamy Temple (Zone-2, 600 KL, ELSR 355 )

1

-

-

... More
350mm dia at SC Colony (Zone-3, 700 KL, ELSR 355 )

1

-

-

... More
250mm dia at Sarridy Palli (Zone-4, 500 KL, ELSR 250 )

1

-

-

... More
150mm dia Vivekananda Nagar (Zone-5, 500 KL, ELSR 160 )

1

-

-

... More
300mm dia at Hill Down Area Near GLBR (Zone-6, 500 KL, ELSR 315 )

1

-

-

... More
350mm dia at Krishna Theater (Zone-7, 500 KL, ELSR 355 )

1

-

-

... More
Supply, delivery , installation of pressure transmitter with a pressure range of up to 16 bar and 64 bar for appropriate usages. Output: 4 to 20 mA, permissible temperature: -20°C to +70°C, IP65 rated with local display. For This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

14

-

-

... More
Supply, delivery , installation of Data Logger with solar powered , battery backup of 5 days including SIM charges for 7 years, transmission rate shall be every 10 minutes cycle that can be configurable from 2 minutes upto 8 hours as needed.This unit shall have additional battery pack to power up ( 5 days backup) for the instruments connected to this item . The data collected from the instruments such as the bulk flow meter , preassure sensors , chlorine etc must be transmitted to the central SCADA Servers via the restfull web services hosted by the servers in the requred data format.

14

-

-

... More
Construction of CC masonry chambers with a openable MS hatch, with lock and key arrangement, steps arrangement, for Electromagnetic Flow meters, Butterfly valves as per pipe sizes including cost of cement, sand, bricks and other required material, including painting and suitable painting material, including labour charges. , Excavation and including wages. Complete as directed by the departmental officer.

-

-

-

1

-

-

1

-

-

4

-

-

... More
Supply delivery and installation of Protection MS grills with lock and key for equipment, instrumentations where ever necessary. This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

1

-

-

... More
Supply, installation , delivery and testing wall mounted ABS plastic enclosure based Online Chlorine Analyzer of Amphreometric or Potentiometric type. Specifications of Range: 0 to 5 mg/L free or total residual chlorine, Resolution 0.01 PPM, Accuracy: +/- 0.05 PPM or better, Cycle Time: 4 minutes, Inlet: Sample Temperature: 5 to 40 °C, operating Temperature: Range 5 to 60 °C. Local LCD Display to display the values. Output: 4-20 mA or 0-10 VDC to integrate into PLC if needed. PH Compensation must be Auto/Manual. All accessories that are required for the must be provided.This item shall include the cost of consumables for the defect liability period of 2 years.

1

-

-

... More
Supply, installation , delivery and testing of wall mounted Turbidity Analyzer make of HACH/ ABB/ Forbes Marshall with specifications of Range 0.00-500.0(NTU/FNU), Operating Temperature : 0 – 60 °C, Displayed Resolution : 0.01 (0.00-19.99), 0.1(20.0-500.0)NTU/FNU, Response Time : Initial response in 1 minute, 15 seconds for a full-scale step change Signal, Sample, Temperature : 0 to 50°C (32 to 122°F), Output 4-20mA to integrate into PLC if needed. Local LCD Display to display the values . This item includes the cost of consumables for the defect liability period of 2 years.

1

-

-

... More
Supply, delivery , installation of Data Logger with solar powered , battery backup of 5 days including SIM charges for 7 years, transmission rate shall be every 10 minutes cycle that can be configurable from 2 minutes upto 8 hours as needed.This unit shall have additional battery pack to power up ( 5 days backup) for the instruments connected to this item . The data collected from the instruments such as the bulk flow meter , preassure sensors , chlorine etc must be transmitted to the central SCADA Servers via the restfull web services hosted by the servers in the requred data format.

1

-

-

... More
Supply delivery and installation of Protection MS grills with lock and key for equipment, instrumentations where ever necessary. This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

1

-

-

... More
Supply , Delivery and installation of manually adjusted preassure reducing valves , accurate pressure ratings. Maximum Upstream Pressure : 20 bar ; Maximum Working Temperature : 80°C. These PRV must be installed at key inlets points of the service reservior.

-

-

-

... More
Lakshmi Narasimha Swamy Temple (Zone-1, 700 KL, ELSR, 355 )

-

-

-

1

-

-

1

-

-

... More
Lakshmi Narasimha Swamy Temple (Zone-2, 600 KL, ELSR 355 )

-

-

-

4

-

-

1

-

-

1

-

-

... More
SC Colony (Zone-3, 700 KL, ELSR 355 )

-

-

-

1

-

-

1

-

-

... More
Sarridy Palli (Zone-4, 500 KL, ELSR 250 )

-

-

-

1

-

-

... More
Vivekananda Nagar (Zone-5, 500 KL, ELSR 160 )

-

-

-

1

-

-

... More
Hill Down Area Near GLBR (Zone-6, 500 KL, ELSR 315 )

-

-

-

3

-

-

... More
Krishna Theater (Zone-7, 500 KL, ELSR 355 )

-

-

-

2

-

-

1

-

-

... More
Supply delivery and comissioning the Handheld Devices for meter reading and bill printing. The power back up of this item shall be for 24 hours , android based with on line and offline capabilities, portable credit/debit card machine reader integrated. The connectivity to the central server will be via rest full services with highest security standards , in json data format as directed by the departmental offer. The bill generation , collection shall reflect across the entire system and the acknoledgement of the receipt shall be sent by SMS to the consumer. SIM charges for 7 years shall be provided. This item shall include the cost of consumables for the defect liability period of 2 years.

6

-

-

... More
Meter Intergations with server Control Centre as directed by the Engineer - in - Charge

1

-

-

... More
Supply, testing installation and commissioning of command control: Reputed / Branded Hardware servers (2 nos) with 8GB RAM and 1TB Hard Disk including for operating system server license CentOS/Lunix , Windows OS, key board mouse with 20" LED monitor, Routers, firewall, bill printer , as required for running the software and internet broad band connection with static IP for for 84 months . 2 nos desktop with windows operating system with 8GB RAM and 1TB Hardisk, key board mouse and 20" LED monitor , 3 Nos work station with 3 chairs for each work station , racks for servers , network wiring , power wiring , etc . This item shall, including cost, conveyance , warrenty for 2 years , complete as directed by the departmental officers.

1

-

-

... More
Supply, testing and commissioning of 55" LED monitor with Ethernet/HDMI/VGA/WIFI with waranty for 2 years

1

-

-

... More
Software shall have modules such as Consumer master , grievence , billing , reports , SMS integration , Access log module, online payment module , consumer logins , metering details , dash board , with authentication and authorisation module , issue tracker , accounting and finance module. The soft ware shall expose restfull web services for further/future integrations with other software. The database, web-server shall be open source, license free, portable with all internationally accepted security standards. Authorisation and user access control shall be implemented for the applications mentioned. The application/software shall provide Restful Web Service interface with JSON data format so that it can be integrated to other centralised software and the Android application. All the data received from the instruments and meters shall be stored in database for a period of 4 years and reports shall be retrieved on demand. The data shall be integrated to the SCADA server as directed by the deparmental officer.

1

-

-

... More
Printer - 3 in one on color printer with refillable ink bank

1

-

-

... More
Supply, Delivery and Installation of 1600VA UPS with solar panels, battery enclosures with doors along with racks, to provide 40 hours battery backup calculated at 50% load. The solar panels should to charge the battery to full capacity in 7 hours of sunshine. As per relevant specification amended time to time for single phase input with input circuit breakers provided protection, sine wave from with sealed battery, maintenance free, recharge time conform to standards. The Batteries shall be of VLRA Type. This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

1

-

-

... More
Providing for Implementation of Environmental Management Plan in the estimate for Giddalur Nagara Panchayat.

-

-

-

... More
Construction Phase (Two years)

-

-

-

... More
Air Quality Monitoring ( 7 Monitoring stations) once in a month for three seasons during the construction period at Intake well, GLBR,WTP, ELSRs & Raw & clear water pipe lines

28

-

-

... More
Noise level Monitoring ( 7 Monitoring stations) once in a month for three seasons during the construction period at Intake well, GLBR,WTP, ELSRs & Raw & clear water pipe lines

28

-

-

... More
Water Quality Monitoring surface / ground (7 Monitoring stations) once in a month for three seasons during the construction period at Intake well, GLBR,WTP, ELSRs & Raw & clear water pipe lines

28

-

-

... More
Compensatory plantation and three years maintenance (Compensatory afforestation ratio is 1:5)-Plant & Tree Gaurds

500

-

-

... More
Sprinkling of water with 5000 Litres capacity tankers (excluding rainy days)

615

-

-

... More
Hiring for 1 No Vehicles for 24 Months during Construction Period including hire charges of vehicle, diesel, lubrication, driver charges, repairs and all incidental charges etc.,

24

-

-

... More
KANIGIRI NAGARA PANCHAYAT (CAPEX)

-

-

-

... More
Providing of Distribution system in Zone -I, Zone -II & Zone -III for a Length of 86591.00 mts including Trench Restoration.

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for pipe line trenches

-

-

-

... More
in ordinery soils by Machenical means

59010

-

-

... More
in ordinery soils by Manual means

25290

-

-

... More
Providing bedding with sand for pipelines trencehs as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification and directed by the Engineer - in - Charge

6390

-

-

... More
Manufacture, supply and delivery of PE 100-PN 6 HDPE pipes confirming to IS 4984-1995 including transportation to work spot, stacking excluding all taxes etc. complete as per S.S

-

-

-

... More
110mm dia.

30523

-

-

... More
160mm dia.

17928

-

-

... More
200mm dia.

17711

-

-

... More
250mm dia.

6444

-

-

... More
315 mm dia.

7989

-

-

... More
355 mm dia.

5996

-

-

... More
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards but excluding GST and as per the Technical Specification.

-

-

-

... More
a) Pipe ends - long neck

-

-

-

... More
110mm dia.

102

-

-

... More
160mm dia.

112

-

-

... More
200mm dia.

98

-

-

... More
250mm dia.

48

-

-

... More
315 mm dia.

72

-

-

... More
355 mm dia

52

-

-

... More
b) MS Flanges

-

-

-

... More
110mm dia.

102

-

-

... More
160mm dia.

112

-

-

... More
200mm dia.

98

-

-

... More
250mm dia.

48

-

-

... More
315 mm dia.

72

-

-

... More
355 mm dia

52

-

-

... More
c) End Caps

-

-

-

... More
110mm dia.

15

-

-

... More
160mm dia.

9

-

-

... More
200mm dia.

9

-

-

... More
d) Reducers

-

-

-

... More
110X125 mm dia

90

-

-

... More
125x140 mm dia

90

-

-

... More
140x160 mm dia

90

-

-

... More
160x180 mm dia

53

-

-

... More
180x200 mm dia

53

-

-

... More
200x225 mm dia

53

-

-

... More
225x250 mm dia

53

-

-

... More
250x280 mm dia

53

-

-

... More
280x315 mm dia

53

-

-

... More
315x355 mm dia

40

-

-

... More
e) TEES

-

-

-

... More
110mm dia.

122

-

-

... More
160mm dia.

72

-

-

... More
200mm dia.

70

-

-

... More
250mm dia.

25

-

-

... More
315 mm dia.

32

-

-

... More
355 mm dia

24

-

-

... More
F)Bends

-

-

-

... More
110mm dia.

61

-

-

... More
160mm dia.

36

-

-

... More
200mm dia.

36

-

-

... More
250mm dia.

14

-

-

... More
315 mm dia.

16

-

-

... More
355 mm dia

12

-

-

... More
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.

-

-

-

... More
110mm dia.

30523

-

-

... More
160mm dia.

17928

-

-

... More
200mm dia.

17711

-

-

... More
250mm dia.

6444

-

-

... More
315 mm dia.

7989

-

-

... More
Supply and delivery of DI Pipes and fittings (Specials) confirming to specification No.I.S.No. 9523 -2000 excluding GST and other duties including transportation and conveyance to work spot and stacking etc., complete as per S.S and as directed by the departmental authorities.

-

-

-

... More
DIDF pipes for scours

-

-

-

... More
100X2.00m on 110 dia mains for scours

20

-

-

... More
100X2.00m on 160 dia mains for scours

12

-

-

... More
100x1.00m long DF pipes for sluice valves

102

-

-

... More
150X2.00m on 200 mm dia mains for scours

14

-

-

... More
150X2.00m on 250 mm dia mains for scours

4

-

-

... More
150x1.00m long DF pipes for sluice valves

60

-

-

... More
200x1.00m long DF pipes for sluice valves

60

-

-

... More
250x1.00m long DF pipes for sluice valves

34

-

-

... More
300x1.00m long DF pipes for sluice valves

54

-

-

... More
350x1.00m long DF pipes for sluice valves

40

-

-

... More
DI Fittings and specials

4400

-

-

... More
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Seating" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) charge of the Tender Document including cost and conveyance and stacking as per standards and as directed by As directed by the Engineer - in - Charge and as per relevent technical specifications excluding GST and other duties

-

-

-

... More
100 mm distrubution

51

-

-

... More
150mm dia for distrubution

30

-

-

... More
200mm dia for distrubution

30

-

-

... More
250mm dia for distrubution

17

-

-

... More
300mm dia for distrubution

27

-

-

... More
350mm dia for distrubution

20

-

-

... More
400mm dia for distrubution

-

-

-

... More
for scour

-

-

-

... More
100mm dia on 110 mm dia mains

10

-

-

... More
100mm dia on 160 mm dia mains

6

-

-

... More
150 mm dia on 200 mm dia lines

7

-

-

... More
150 mm dia on 250 mm dia lines

2

-

-

... More
80mm dia Isolation

61

-

-

... More
Manufacture, supply and delivery of Single Chamber DI Air Valve with Body and cover in Ductile Iron of grade SG 400/12 or equivalent grade as per I.S. I.S.14845 and subsequent revisions. All internal parts such as float, shell etc., all cover bolts, of stainless steel, and Gaskets and seals of EPDM food grade quality Epoxy powder coating (EP-P) inside and outside colour blue. Drilled as per IS:1538. PN16 excluding GST and other duties

-

-

-

... More
80mm dia air valves

61

-

-

... More
Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves as directed by Engineer-in-charge

-

-

-

... More
100 mm distrubution

51

-

-

... More
150mm dia for distrubution

30

-

-

... More
200mm dia for distrubution

30

-

-

... More
250mm dia for distrubution

17

-

-

... More
300mm dia for distrubution

27

-

-

... More
350mm dia for distrubution

20

-

-

... More
for scour

-

-

-

... More
100mm dia on 110 mm dia mains

10

-

-

... More
100mm dia on 160 mm dia mains

6

-

-

... More
150 mm dia on 200 mm dia lines

7

-

-

... More
150 mm dia on 250 mm dia lines

2

-

-

... More
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., completeas directed by Engineer-in-charge

-

-

-

... More
80 mm dia on 150,250,315,355 and 400 mm pipes

61

-

-

... More
Construction of sluice and scour Valve Chamber as per type design drawing with CC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work and as directed by the Engineer-in-Charge of the work and as per Technical Specification

-

-

-

... More
100 mm distrubution

51

-

-

... More
150mm dia for distrubution

30

-

-

... More
200mm dia for distrubution

30

-

-

... More
250mm dia for distrubution

17

-

-

... More
300mm dia for distrubution

27

-

-

... More
350mm dia for distrubution

20

-

-

... More
for scour

-

-

-

... More
100mm dia on 110 mm dia mains

10

-

-

... More
100mm dia on 160 mm dia mains

6

-

-

... More
150 mm dia on 200 mm dia lines

7

-

-

... More
150 mm dia on 250 mm dia lines

2

-

-

... More
Construction of Air Valve Chamber as per type design drawing with CC including, plastering, RCC cover slabs etc. including cost and conveyance of all material and all labour charges etc. complete as per S.S for finished item of work and as directed by the Engineer-in-Charge of the work and as per Technical Specification

-

-

-

... More
80 mm dia on 160 mm pipe

20

-

-

... More
80 mm dia on 200 mm pipe

19

-

-

... More
80mm dia 250 mm pipe

7

-

-

... More
80mm dia 315 mm pipe

9

-

-

... More
80mm dia 355 mm pipe

6

-

-

... More
Lowering the C.I. Pipes, D.I. Pipes of all classes and fittings with flanged ends carefully into the trenches and laying them true to alignment and gradient including all sundries, but excluding conveyance from source of supply as per BIS No.3114/94.

-

-

-

... More
100 mm dia

182

-

-

... More
150 mm dia

125

-

-

... More
200 mm dia

79

-

-

... More
250 mm dia

41

-

-

... More
300 mm dia

63

-

-

... More
350 mm dia

46

-

-

... More
Jointing the C.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85.

-

-

-

... More
80 mm dia

61

-

-

... More
100 mm dia

283

-

-

... More
150 mm dia

332

-

-

... More
200 mm dia

196

-

-

... More
250 mm dia

96

-

-

... More
300 mm dia

150

-

-

... More
350 mm dia

46

-

-

... More
Cutting BT road surface as well as asphalt (75mm thick) including water bound. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work.

3200

-

-

... More
Cutting the CC road surface. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work.

840

-

-

... More
Cutting the open water bound macadam. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work.

1920

-

-

... More
Filling crushur stone dust in pipe line trenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH

10760

-

-

... More
Using Concrete mixture up to Plinth Level : Plain Cement concrete nominal mix M-30 (Cement : fine aggregate: coarse aggregate ) using 20mm size Hard Granite Machine Crushed Graded Metal including cost and conveyance of all materials like cement, sand, coarse aggregate water etc., to site , seigniorage charges on all materials, labour charges , for mixing , laying, concrete , ramming in 15 cm layers, finishing top surface to the required level curing etc., complete for finished item of work with nomonal reinforcement for trench restoration. for BT&CC roads

1276

-

-

... More
Providing 15mm dia House Service Connection as per standard specification including the cost of the materials like Clamp Saddle,Ferrule Tapping Saddle confirming to I.S stadard manufactured from virgin resin of PE-80 , Compression Elbows, MDPE PE100 Pipe including lowering, laying and jointing including earth work excavation,UPVC Casing pipe with Two Calmps for drain crossings,Drilling of Holes for RR Masonary and CC Walls , Boring&Tunneling below CC &BT Roads ,saw cutting of groves in CC Roads and refilling the pipe line trench after laying the pipe line and including cost of 15mm dia meter of BIS standard etc complete as directed by departmental officer for finished item of work.( CC Roads and BT Roads should not be distrubed)

-

-

-

... More
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD SIDE (Minimum 4.0 Mts MDPE pipe)

3393

-

-

... More
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD OPPOSITE SIDE IN CC &BT ROADS (Minimum 7.0 Mts MDPE pipe)

1357

-

-

... More
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD OPPOSITE SIDE IN EARTHEN ROADS (Minimum 7.0 Mts MDPE pipe)

2036

-

-

... More
Supply, deliver and installation of bulk flow meter including consumer meters and other instruments in the deliveries for the DMAs of Takatipalem (Zone-1, 750 KL, ELSR, 250mm), Near Veterinary Hospital (Zone-2, 1400 KL, ELSR, 300mm), Near Nagula Cheruvu (Zone-3A/3B, 900 KL, ELSR, 250mm)

-

-

-

... More
Takatipalem (Zone-1, 750 KL, ELSR, 250mm), Near Veterinary Hospital (Zone-2, 1400 KL, ELSR, 300mm), Near Nagula Cheruvu (Zone-3A/3B, 900 KL, ELSR, 250mm).

-

-

-

... More
Supply, delivery, installation and integration of Electromagnetic flow meter with IP68 and as per ISO 9001:2008,meter tube should be SS304 material, CS flanges of PN10/PN16 rating liner - hard rubber/polyurethane with WRAS or NSF drinking water approval, electrodes - SS316, 2 measuring electrodes for measuring,1 ground elctrode,1 empty pipe detection, coil housing - SS304 fully welded construction for corrosion grade/painted steel with protective lacquering (corrosive protection, class up to C5-1) as per EN ISO-12944/carbon steel, IP68 protection, Accuracy +/- 0.5% of measured value inclusive of linearity, repeatability etc, grounding rings of SS316/304. Flow transmitter microprocessor based wall mounted, flow ranges of the meter (full flow range). The overall uncertainty of the calibration rig should be atleast three times better than the uncertainty of the full bore electromagnetic flow meter. The competent government authority such as FCRI/NABL must certify the test facility etc. The EMF must be integrated with local SCADA server and the reading shall be captured all times 24x7. The flowmeter values must be persistent and there is no loss of data. The meter shall have display panel for displaying the readings according. This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

-

-

-

... More
300mm dia Takatipalem (Zone-1, 750 KL, ELSR, 315 Ø)

1

-

-

... More
300mm dia Near Veterinary Hospital (Zone-2, 1400 KL, ELSR, 315 Ø)

1

-

-

... More
350mm dia Near Nagula Cheruvu (Zone-3A/3B, 900 KL, ELSR, 355 Ø)

1

-

-

... More
Supply, delivery , installation of pressure transmitter with a pressure range of up to 16 bar and 64 bar for appropriate usages. Output: 4 to 20 mA, permissible temperature: -20°C to +70°C, IP65 rated with local display. For This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

6

-

-

... More
Supply, delivery , installation of Data Logger with solar powered , battery backup of 5 days including SIM charges for 7 years, transmission rate shall be every 10 minutes cycle that can be configurable from 2 minutes upto 8 hours as needed.This unit shall have additional battery pack to power up ( 5 days backup) for the instruments connected to this item . The data collected from the instruments such as the bulk flow meter , preassure sensors , chlorine etc must be transmitted to the central SCADA Servers via the restfull web services hosted by the servers in the requred data format.

6

-

-

... More
Construction of CC masonry chambers with a openable MS hatch, with lock and key arrangement, steps arrangement, for Electromagnetic Flow meters, Butterfly valves as per pipe sizes including cost of cement, sand, bricks and other required material, including painting and suitable painting material, including labour charges. , Excavation and including wages. Complete as directed by the departmental officer.

-

-

-

2

-

-

1

-

-

... More
Supply, installation , delivery and testing wall mounted ABS plastic enclosure based Online Chlorine Analyzer of Amphreometric or Potentiometric type. Specifications of Range: 0 to 5 mg/L free or total residual chlorine, Resolution 0.01 PPM, Accuracy: +/- 0.05 PPM or better, Cycle Time: 4 minutes, Inlet: Sample Temperature: 5 to 40 °C, operating Temperature: Range 5 to 60 °C. Local LCD Display to display the values. Output: 4-20 mA or 0-10 VDC to integrate into PLC if needed. PH Compensation must be Auto/Manual. All accessories that are required for the must be provided.This item shall include the cost of consumables for the defect liability period of 2 years.

1

-

-

... More
Supply, installation , delivery and testing of wall mounted Turbidity Analyzer make of HACH/ ABB/ Forbes Marshall with specifications of Range 0.00-500.0(NTU/FNU), Operating Temperature : 0 – 60 °C, Displayed Resolution : 0.01 (0.00-19.99), 0.1(20.0-500.0)NTU/FNU, Response Time : Initial response in 1 minute, 15 seconds for a full-scale step change Signal, Sample, Temperature : 0 to 50°C (32 to 122°F), Output 4-20mA to integrate into PLC if needed. Local LCD Display to display the values . This item includes the cost of consumables for the defect liability period of 2 years.

1

-

-

... More
Supply, delivery , installation of Data Logger with solar powered , battery backup of 5 days including SIM charges for 7 years, transmission rate shall be every 10 minutes cycle that can be configurable from 2 minutes upto 8 hours as needed.This unit shall have additional battery pack to power up ( 5 days backup) for the instruments connected to this item . The data collected from the instruments such as the bulk flow meter , preassure sensors , chlorine etc must be transmitted to the central SCADA Servers via the restfull web services hosted by the servers in the requred data format.

1

-

-

... More
Supply delivery and installation of Protection MS grills with lock and key for equipment, instrumentations where ever necessary. This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

1

-

-

... More
Supply , Delivery and installation of manually adjusted preassure reducing valves , accurate pressure ratings. Maximum Upstream Pressure : 20 bar ; Maximum Working Temperature : 80°C. These PRV must be installed at key inlets points of the service reservior.

-

-

-

... More
Takatipalem (Zone-1, 750 KL, ELSR, 315 Ø)

-

-

-

1

-

-

1

-

-

1

-

-

... More
Near Veterinary Hospital (Zone-2, 1400 KL, ELSR, 315 Ø)

-

-

-

1

-

-

1

-

-

1

-

-

... More
Near Nagula Cheruvu (Zone-3A/3B, 900 KL, ELSR, 355 Ø )

-

-

-

1

-

-

1

-

-

1

-

-

... More
Supply delivery and comissioning the Handheld Devices for meter reading and bill printing. The power back up of this item shall be for 24 hours , android based with on line and offline capabilities, portable credit/debit card machine reader integrated. The connectivity to the central server will be via rest full services with highest security standards , in json data format as directed by the departmental offer. The bill generation , collection shall reflect across the entire system and the acknoledgement of the receipt shall be sent by SMS to the consumer. SIM charges for 7 years shall be provided. This item shall include the cost of consumables for the defect liability period of 2 years.

7

-

-

... More
Meter Intergations with server Control Centre as directed by the Engineer - in - Charge

1

-

-

... More
Supply, testing installation and commissioning of command control: Reputed / Branded Hardware servers (2 nos) with 8GB RAM and 1TB Hard Disk including for operating system server license CentOS/Lunix , Windows OS, key board mouse with 20" LED monitor, Routers, firewall, bill printer , as required for running the software and internet broad band connection with static IP for for 84 months . 2 nos desktop with windows operating system with 8GB RAM and 1TB Hardisk, key board mouse and 20" LED monitor , 3 Nos work station with 3 chairs for each work station , racks for servers , network wiring , power wiring , etc . This item shall, including cost, conveyance , warrenty for 2 years , complete as directed by the departmental officers.

1

-

-

... More
Supply, testing and commissioning of 55" LED monitor with Ethernet/HDMI/VGA/WIFI with waranty for 2 years as directed by the Engineer - in - Charge

1

-

-

... More
Software shall have modules such as Consumer master , grievence , billing , reports , SMS integration , Access log module, online payment module , consumer logins , metering details , dash board , with authentication and authorisation module , issue tracker , accounting and finance module. The soft ware shall expose restfull web services for further/future integrations with other software. The database, web-server shall be open source, license free, portable with all internationally accepted security standards. Authorisation and user access control shall be implemented for the applications mentioned. The application/software shall provide Restful Web Service interface with JSON data format so that it can be integrated to other centralised software and the Android application. All the data received from the instruments and meters shall be stored in database for a period of 4 years and reports shall be retrieved on demand. The data shall be integrated to the SCADA server as directed by the deparmental officer.

1

-

-

... More
Printer - 3 in one on color printer with refillable ink bank as directed by the Engineer - in - Charge

1

-

-

... More
Supply, Delivery and Installation of 1600VA UPS with solar panels, battery enclosures with doors along with racks, to provide 40 hours battery backup calculated at 50% load. The solar panels should to charge the battery to full capacity in 7 hours of sunshine. As per relevant specification amended time to time for single phase input with input circuit breakers provided protection, sine wave from with sealed battery, maintenance free, recharge time conform to standards. The Batteries shall be of VLRA Type. This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

1

-

-

... More
Provide installing and giving Satisfactory field testing of battery Operated "B" Class 15mm AMR Ultrasonic Meters having no moving part in Contact with water with magnetically sealed coupled and Hermitically sealed register ,with full brass body confirming to ISO 4064 along with manufacturing test certificate with battery life of min.10 years with GSM /RF Technology for communication to server with PC Software including all materials required for fixing ,labour and giving satisfactory leak proof test etc Complete,General Specifications:-1) Meter should be battery operated with no moving parts,low prtesser ,loss,dry type as per FCRI /MID.2)Display:- 8 digit LCD,3)Encloser :-Protection class IP 68 4) Tempature :-Ambit 50deg .C 5) Pressure :-minimum life of 10 Years 7) Memory built -In and should have storage for at least 12 months with daily /monthly accumulated totailised data with time and date should be available .It should able to access memory of the meter through serial communications 8) End Connection:- Screwed up to 40mm BSP/Npt coupling 9) Installation:- Should be able to install in any orientation 10) Transducre :-Inbuilt as per detailed Technical Specifications . 11) The acceptance /routine test shall be either conducted by M/S.Fliud Control Research In stitute ,Palght,Kerala or any of the Laboratories apporved by the National Accerditation Board for Calibration Laboratories (NABL) or EEC pattern apporaval certificates with at least 5 years battery life, including dual channel data loggers ,fixing specials,installation at site etc.. including providing and fixing in position poly propylene water meter box to accommodate water meter all charges and excluding GST

6786

-

-

... More
Implementation of Environmental Management Plan in Kanigiri Nagara Panchayat

-

-

-

... More
Construction Phase (Two years)

-

-

-

... More
Air Quality Monitoring (4 Monitoring station) once in a month for three seasons during the construction period at Distribution network

18

-

-

... More
Noise level (4 Monitoring station) once in a month for three seasons during the construction period at Distribution network

18

-

-

... More
Water Quality Monitoring surface / ground (4 Monitoring station) once in a month for three seasons during the construction period at Distribution network

25

-

-

... More
Compensatory plantation and three years maintenance (Compensatory afforestation ratio is 1:5)-plants & tree guards

120

-

-

... More
Sprinkling of water with 5000 Litres capacity tankers (excluding rainy days)

1000

-

-

... More
ADDANKI NAGARA PANCHAYAT (OPEX)

-

-

-

... More
Operation and maintainance for the Seven years including Defective Liability Period

-

-

-

... More
Valve Operator/Turn Cocks

162

-

-

... More
Helpers for Distribution

243

-

-

... More
Repairs to pumpsets & Water pipe lines ( for Five years )

-

-

-

... More
iv)Replacement of glands of sluice valves

65

-

-

... More
v) Replacements of balls of Air valves

55

-

-

... More
Purchase pipe jointing materials, etc

-

-

-

... More
315mm dia HDPE TEE'S

2

-

-

... More
250 mm dia HDPE TEE'S

2

-

-

... More
200 mm dia HDPE TEE'S

2

-

-

... More
160 mm dia HDPE TEE'S

2

-

-

... More
110 mm dia HDPE TEE'S

330

-

-

... More
110 mm dia HDPE BENDS

330

-

-

... More
Providing qualified diploma personal with minimum 2 Years of experience in Computers/ bulk flow meters and instruments maintainence etc. The member task is to maintain the system , including daily routine checks of all field instruments etc as directed by the departmental officers ( 1 techinican x 366 days x 7 years = 2562 days ) inc ESI, PF and other statutory levies as directed by the departmental officers

2562

-

-

... More
Service Charge for bill generations , collections and maintainence for 3400 consumers x 12 months x 7 years =285600. This item includes cost of consumables .

285600

-

-

... More
Operation Phase ( One year)

-

-

-

... More
Air Quality Monitoring (4 Monitoring station) once in a month at Distribution network

5

-

-

... More
Noise level (4 Monitoring station) once in a month at Distribution network

5

-

-

... More
Water Quality Monitoring surface / ground (4 Monitoring station) once in a month at Distribution network

30

-

-

... More
Chimakurthy Nagara Panchayat (OPEX)

-

-

-

... More
Personal required for operating Valves in distribution lines

-

-

-

... More
Valve Operator/Turn Cocks

162

-

-

... More
Helpers for Distribution

243

-

-

... More
Repairs to Water pipe lines

-

-

-

... More
iv)Replacement of glands of sluice valves

20

-

-

... More
v) Replacements of balls of Air valves

20

-

-

... More
Purchase of pipe jointing materials, etc

-

-

-

... More
110mm dia MS flanges

100

-

-

... More
160mm dia MS flanges

75

-

-

... More
200mm dia MS flanges

30

-

-

... More
250mm dia MS flanges

30

-

-

... More
315 mm dia MS flanges

30

-

-

... More
110mm dia PE 100 PN6 HDPE PIPE

100

-

-

... More
160mm dia PE 100 PN6 HDPE PIPE

50

-

-

... More
200mm dia PE 100 PN6 HDPE PIPE

25

-

-

... More
250mm dia PE 100 PN6 HDPE PIPE

20

-

-

... More
110mm dia HDPE TEES

60

-

-

... More
160mm dia HDPE TEES

20

-

-

... More
200mm dia HDPE TEES

30

-

-

... More
250mm dia HDPE TEES

30

-

-

... More
110mm dia HDPE LONG NECK

75

-

-

... More
160mm dia HDPE LONG NECK

50

-

-

... More
200mm dia HDPE LONG NECK

45

-

-

... More
250mm dia HDPE LONG NECK

20

-

-

... More
Providing qualified diploma personal with minimum 2 Years of experience in Computers/ bulk flow meters and instruments maintainence etc. The member task is to maintain the system , including daily routine checks of all field instruments etc as directed by the departmental officers ( 1 techinican x 366 days x 7 years = 2562 days ) inc ESI, PF and other statutory levies as directed by the departmental officers

2562

-

-

... More
Service Charge for bill generations , collections and maintainence for 4190 consumers x 12 months x 7 years = 351960 . This item includes cost of consumables .

351960

-

-

... More
Environmental Implementation Operation Phase ( One year)

-

-

-

... More
Air Quality Monitoring (4 Monitoring station) once in a month for three seasons during at Distribution network

11

-

-

... More
Noise level (4 Monitoring station) once in a month for three seasons during at Distribution network

11

-

-

... More
Water Quality Monitoring surface / ground (4 Monitoring station) once in a month for three seasons at Distribution network

16

-

-

... More
GIDDALUR NAGARA PANCHAYAT (OPEX)

-

-

-

... More
Personal required for operating Valves in distribution lines

-

-

-

... More
Valve Operator/Turn Cocks

162

-

-

... More
Helpers for Distribution

243

-

-

... More
Repairs to Water pipe lines ( for Five years )

-

-

-

... More
iv)Replacement of glands of sluice valves

20

-

-

... More
v) Replacements of balls of Air valves

20

-

-

... More
Purchase pipe jointing materials, etc

-

-

-

... More
110mm dia MS flanges

100

-

-

... More
160mm dia MS flanges

75

-

-

... More
200mm dia MS flanges

30

-

-

... More
250mm dia MS flanges

30

-

-

... More
315 mm dia MS flanges

30

-

-

... More
110mm dia PE 100 PN6 HDPE PIPE

100

-

-

... More
160mm dia PE 100 PN6 HDPE PIPE

50

-

-

... More
200mm dia PE 100 PN6 HDPE PIPE

25

-

-

... More
250mm dia PE 100 PN6 HDPE PIPE

20

-

-

... More
110mm dia HDPE TEES

60

-

-

... More
160mm dia HDPE TEES

20

-

-

... More
200mm dia HDPE TEES

30

-

-

... More
250mm dia HDPE TEES

30

-

-

... More
110mm dia HDPE LONG NECK

75

-

-

... More
160mm dia HDPE LONG NECK

50

-

-

... More
200mm dia HDPE LONG NECK

45

-

-

... More
250mm dia HDPE LONG NECK

20

-

-

... More
Providing qualified Diploma with minimum 2 Years of experience in SCADA/Computers , flow meters and instruments maintainence etc including daily routine checks on HMI , Flowmeter , PLC at all locations around the project and also operate ( 1 techinican x 366 days x 7 years = 2562 days ) inc ESI, PF and other statutory levies as directed by the departmental officers

2562

-

-

... More
Service Charge for bill generations , collections and maintainence for 5023 consumers x 12 months x 7 years = 421932. This item includes cost of consumables .

421932

-

-

... More
Implementation of Environmental Management Operation Phase ( One year)

-

-

-

... More
Air Quality Monitoring ( 4 Monitoring stations) once in a month for three seasons during the construction period

12

-

-

... More
Noise level Monitoring (4 Monitoring stations) once in a month for three seasons during the construction period

8

-

-

... More
Water Quality Monitoring surface / ground (4 Monitoring stations) once in a month for three seasons during the construction period

32

-

-

... More
KANIGIRI NAGARA PANCHAYAT (OPEX)

-

-

-

... More
Manning, Operation and Maintenance of Chittoor Municpal Corporation Water Supply Improvement Scheme For 7 Years.

-

-

-

... More
Personal required for operating Valves in distribution lines

-

-

-

... More
Valve Operator/Turn Cocks

81

-

-

... More
Helpers for Distribution

324

-

-

... More
Repairs to pumpsets & Water pipe lines ( for Five years )

-

-

-

... More
iv)Replacement of glands of sluice valves

20

-

-

... More
v) Replacements of balls of Air valves

20

-

-

... More
Provision towards purchase pipe jointing materials, etc

-

-

-

... More
MS flanges

-

-

-

... More
110mm dia

100

-

-

... More
160mm dia

75

-

-

... More
200mm dia

30

-

-

... More
250mm dia

30

-

-

... More
315 mm dia

30

-

-

... More
110mm dia PE 100 PN6 HDPE PIPE

50

-

-

... More
160mm dia PE 100 PN6 HDPE PIPE

20

-

-

... More
200mm dia PE 100 PN6 HDPE PIPE

10

-

-

... More
250mm dia PE 100 PN6 HDPE PIPE

10

-

-

... More
110mm dia HDPE TEES

30

-

-

... More
160mm dia HDPE TEES

10

-

-

... More
200mm dia HDPE TEES

10

-

-

... More
250mm dia HDPE TEES

10

-

-

... More
110mm dia HDPE LONG NECK

25

-

-

... More
160mm dia HDPE LONG NECK

20

-

-

... More
200mm dia HDPE LONG NECK

20

-

-

... More
250mm dia HDPE LONG NECK

20

-

-

... More
Providing qualified diploma personal with minimum 2 Years of experience in Computers/ bulk flow meters and instruments maintainence etc. The member task is to maintain the system , including daily routine checks of all field instruments etc as directed by the departmental officers ( 1 techinican x 366 days x 7 years = 2562 days ) inc ESI, PF and other statutory levies as directed by the departmental officers

2562

-

-

... More
Service Charge for bill generations , collections and maintainence for 6486 consumers x 12 months x 7 years = 570024 . This item includes cost of consumables .

570024

-

-

... More
Implementation of Environmental Plan Operation Phase ( One year)

-

-

-

... More
Air Quality Monitoring (4 Monitoring station) once in a month Distribution network

12

-

-

... More
Noise level (4 Monitoring station) once in a month at Distribution network

12

-

-

... More
Water Quality Monitoring surface / ground (4 Monitoring station) once in a month at Distribution network

16

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.