Military Engineer Services Tender
... More
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date8 Feb 2025
Closing Date22 Feb 2025
Tender Amount₹ 3,26,000
Costs
EMD
₹ 6,520Document Cost
₹ 300Tender Fee
Refer Documents
Summary
Provn Of Misc B/r And E/m Minor Work At Certain Locations At Af Stsation Suryalanka
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_697007_1Tender No
AGE(I)/SL/8650Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for 10mm thick cement plaster in CM 1:6 on fair faces of brick work, surfaces finised even and smooth with out using extra cement
10
-
-
... More
M&L for two coats of cement base paint over a coat of primer on newly plastered surfaces including preparation of surfaces complete all as specified and directed
10
-
-
... More
Hard core of guage n.exc 63mm, with broken stone or boulders, deposited spread and levelled in layers n.ec 15 cm thick, watered and well rammed to a true surface all as specified and as directed.
2.25
-
-
... More
M&L for 100mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregates as in sub base of floor complete all as specified and directed.
15
-
-
... More
M&L for 40m thick plain cement concrete type B-1, 1:2:4 mix using 20mm graded stone aggregate as in floors, paths pavings etc surface finished even and smooth without using extra cement all as specified and directed
15
-
-
... More
M&L for 100mm thick plain cement concrete type B-0, 1:2:4 mix using 12.5mm graded stone aggregate as in floor, paths pavings etc surface finished even and smooth without using extra cement all as specified and directed
15
-
-
... More
Returning filing in including spreading levelling watering and well ramminng in layers not exceeding 25 cm thick in soft/loose soil
1.98
-
-
... More
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point
1.19
-
-
... More
Exc in trenches not exc. 1.5 m wide and not exc. 1.5 in depth for laying of cable. and getting out in any type of soil complete all as specified and directed
12.69
-
-
... More
Returning filling in including spreading levelling watering and well ramming in layers not exc. 25 cm thick each complete all as specified and directed
7.32
-
-
... More
Removing excavated material to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point of any type of soil complete all as specified and directed
5.37
-
-
... More
Supply and laying new dry river sand laid in trenches 8cm below the cable and 15cm above the cable and punned to 18cm as cable cushioning and covering all as directed.
Note:- Punned quantity will be measured paid at this item.
3.81
-
-
... More
S & L brick covering with width equal to length of brick as the mechanical protction to cable with well burned sub class 'B' laid in trenches flat complete all as specified and directed.
0.41
-
-
... More
Supply and lay Tubes,'light grade' galvansized 40mm dia for cable protection with all fitting and fixed complete to walls and ceiling or laid in floors/road crossing all as specified.
10
-
-
... More
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm 3.5 core
50
-
-
... More
Earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 32×6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
4
-
-
... More
Shifting/transferring of 50 KVA DG set from 402 D/F to GDCC bldg near CSD of 6-7 Km distance through proper method and as per direction by Engr-in-Charge, including removing of connection from existing location and providing connection at new locatoin as per direction.
1
-
-
... More
Supply and fix Havells IHCNFO0063 Onload Changeover Switch 4 Pole 63 Amp 415 Volt
1
-
-
... More
M&L for construction of 1.20m dia soakage well having effective depth 3m including foundation earthwork, excavation, walls of honeycombed masonry with top ring of M25 grade concrete intercepting chamber and screen chamber made of brick masonry, RCC cover slab of M25 grade concrete/SFRC cover, inter connecting pipes of RCC/DWC complete filled with brick bats etc complete all as specified and shown on drawings.
1
-
-
... More
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage capacity of 80 Ltr and nominal cooling capacity of 40 Ltr per hour including necessary suitable size of PPR Pipe required for inlet connection not more than 10 mts and size of 25mm dia, Brass insert Gate valve of suitable size and PVC connection pipe suitable for connection inlet pipe to Water cooler inlet of size 20mm not lessthan 60cm complete all as specified and as directed.
1
-
-
... More
Cutting PPR/ PVC/ UPVC/ GI pipe of any bore upto 32 mm dia and reducing to required size by inserting Tee and other specials for connection to inlet of Water cooler complete all as specified and as directed.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%