Military Engineer Services Tender
... More
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date12 May 2025
Closing Soon2 Jun 2025
Tender Amount₹ 47,65,000
Costs
EMD
₹ 95,300Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_707059_1Tender No
8282/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
(q)starting and checking the running condition of cooling tower fan
(r)starting the pump and checking the running condition including checking the NRVs
(s)cleaning condensate drain tray
(t)checking the cooling tower nozzles for proper spray and replacing the same if necessary
u)Descaling the condenser and replacing the condenser end shield gaskets
Record of these shall be maintained and submitted monthly to engineer in charge The above quoted rate is inclusive of all spare parts apart from below mentioned spare parts which will be paid seperately to make the unit completely functional, T&P manpower required in the site
-
-
-
... More
All as per item No. 1.00 above, but for 25 Tr x 3 Nos. at 43 central bldg
9
1
9
... More
All as per item No. 1.00 above, but for 20 Tr x 2 Nos. at 15 bldg
9
-
-
... More
All as per item No. 1.00 above, but for 11 Tr x 2 Nos. at 17 bldg
9
-
-
... More
Repairs, overhauling and servicing of upto 30 Tr AC Plant compressor by stripping out both end covers, cylinder head, cylinders, connecting rod, crank shaft, oil pump, side covers, bush bearings etc.,and refrigerant taking the cylinder for reuse (if available) of unserviceable worn out parts in the compressor, cleaning the system with CO2/Nitrogen gas for leak detection for minimum 24 Hrs, after flushing out the system, vacuumization and charging with refrigerant gas & compressor oil and testing the unit on no load and full load conditions all as specified and directed.
Note:- Supply only refrigerant gas, compressor oil and spare parts for the compressors will be measured and paid under relevant items of Schedule ’A’.
6
-
-
... More
Supply only following spare parts suitable for SMC 6-65 ‘Accel’ make or equivalent all as specified and directed.
-
-
-
... More
Bushing with collar standard
2
-
-
... More
Shaft seal assembly
1
-
-
... More
Bearing bushing
6
-
-
... More
Gear Wheel
1
-
-
... More
Single frame (unload -65)
2
-
-
... More
Rocker for unload mechanism
12
-
-
... More
Bearing cup
12
-
-
... More
Spring holder
12
-
-
... More
Spring
12
-
-
... More
Cup washer
12
-
-
... More
Crank shaft
1
-
-
... More
Half section of bearing standard
6
-
-
... More
Bush for piston pin
6
-
-
... More
Castie nut
12
2
24
... More
Split pin
12
-
-
... More
Piston with pin & rings
6
-
-
... More
Cylinder liner
6
-
-
... More
Unloading ring with pin
3
-
-
... More
Tension spiral
6
-
-
... More
Suction valve ring plate
6
-
-
... More
Valve spring
6
-
-
... More
Suction valve retaining plate
6
-
-
... More
Discharge valve seat
6
-
-
... More
Discharge valve ring plate
6
-
-
... More
Oil pressure regulating valve
1
-
-
... More
Safety valve assembly
1
-
-
... More
Set of gasket
1
-
-
... More
Set of neoprene “O” Ring
1
-
-
... More
Set of dowty rings
1
-
-
... More
Set of sealing rings
1
-
-
... More
Supply only following spare parts suitable for 5F-20 of Make ‘Carrier’ 15TR or equivalent all as specified and directed.
-
-
-
... More
Crank shaft
2
-
-
... More
Connecting rod
8
-
-
... More
Piston
8
-
-
... More
Piston pin
8
-
-
... More
Piston lock
8
-
-
... More
Suction reed
8
-
-
... More
Discharge reed
8
-
-
... More
Suction valve springs
40
-
-
... More
Discharge valve springs
40
-
-
... More
Discharge valve assembly
8
-
-
... More
Valve plate
4
-
-
... More
Spring lifter pin
40
-
-
... More
Gasket set
2
-
-
... More
Collecing rod bearings
16
-
-
... More
Oil pump assembly with bush
2
-
-
... More
Shaft seal assebly
3
-
-
... More
Pump end bearing
2
-
-
... More
Seal end bearing
2
-
-
... More
Thrust washer
4
-
-
... More
Cylinder liner
4
-
-
... More
Piston ring and oil ring
16
-
-
... More
Supply only R-22 gas all as specified and directed.
305
-
-
... More
Supply only compressor oil all as specified and directed.
150
-
-
... More
Material and labour for descaling of upto 30TR condensers by using HCL acid with continuous circulation method using circulation pump, finally neutralizing with fresh water, opening both end covers of shell and tube condensers, cleaning of copper tubes manually by using nylon brushes, re-fixing the end covers with new neoprene rubber gaskets, commissioning after complete performance test of the system all as specified and directed.
Note:-The quoted rate is inclusive of descalling all the units in given single location
16
-
-
... More
Material and labour for taking out the defective pressure cut-outs of any range and model and supply & fix new pressure cut-outs, connecting the pressure lines/control wiring, leak testing and commissioning all as specified and directed
-
-
-
... More
HP/LP pressure cut-out MP-15
4
-
-
... More
Oil pressure cut-out MP-55
4
-
-
... More
S&F for VVE-70 model expansion valve of Sporlon make with necessary modification, brazing, lead testing and commissioning including taking out old unsv expansion valve complete all as specified and directed.
2
-
-
... More
All as per item No. 12.00 above, but for VVE- 52
2
-
-
... More
All as per item No. 12.00 above, but for HVE- 16
2
-
-
... More
All as per item No. 15 above, but for HVE - 20
2
-
-
... More
Material and labour for monthly cleaning of entire indoor substation buildings inside wall, ceiling, floor and outside wall, plinth protection with suitable brush/broom/wiper, removing wild vegitation around substation building complete all as specified and directed.
45
-
-
... More
Taking down existing corroded/ unserviceable portion of MS flat/angle iron supports/ channels /Chequerred plates of various sizes fitted in electrical panels in AC plants, stair cases and supply & fix MS flat/ angle iron/Chequerred plates /ladders as per requirement including necessary bolting/ welding etc. all as as specified and directed.
1000
-
-
... More
Supply and fix in repairs pilot solenoid valve to the refrigerant system, reconnecting the refrigeration piping including leak testing, brazing/flaring to the pipe line whererever required all as specified and directed.
4
-
-
... More
Supply and fix in repairs loading solenoid valve to the refrigerant system, reconnecting the refrigeration piping including leak testing, brazing/flaring to the pipe line whererever required all as specified and directed.
4
-
-
... More
Material and labour for replacement of suction lines, oil pressure lines, HP/LP lines and cut out lines with existing size copper tubing including necessary brazing, flaring alongwith pumping down, and recharging after complete replacement of copper tubing, neutralizing after the pressure hold good for at least 24 hours vacuumization of system, testing and commissioning of air conditioning plants all as specified and directed.
Note : - Refrigerant gas shall be measured and paid for separately as supply only and pressure testing by replacing old flare nuts complete
4
-
-
... More
Material and labour for preparation of surfaces by scrapping and removing rusted portion with wire brush and applying one coat of synthetic enamel paint for complete refrigeration system, in-let/out-let pipe lines, compressor unit, condenser pump set, control LT panel board duct covers, cooling tower stand including and applying one coat of white/colour wash to chiller pipe line all as specified and directed
4
-
-
... More
Material and labour for complete checking, servicing/ rectification of electrical circuits for all units and control wiring showing phase sequence with proper lugging of AC plant control panel including replacement of fused indication lamps with new ones, cleaning of all power contacts, rectification of minor defects in Ammeters and Voltmeters including necessary modification/rewiring etc., testing and commissioning and painting the outer body all as specified and directed. Note :- (i) Material such as indication lamp, ammeter, voltmeter will be measured and paid separately
6
-
-
... More
(ii) Items apart from supply only which are required in site are deemed to be included in the quoted rate.Material such as indication lamp, ammeter, voltmeter will be measured and paid separately as supply only.Any other items equired to make the unit functional is deemed to be included in the quoted rate. Contractor has to deploy manpower at the worksite to attend the breakdown calls received from representatives during two shifts throughout the week including sundays & holidays and on emergencies in third shift shall be attended, preventive maintenance for the entire duration of contract.It is the contractors responsibility to make the unit functional and sufficient stock of spares shall be maintained to rectify the breakdown within scheduled period. Cleaning, stacking, sorting, handling and upkeeping of maintenance shall be carried out by contractor.
-
-
-
... More
Supply MCCB of 250 Amps, 4 pole, 36 KA, AC supply 50Hz, 415 V complete all as specified and directed.
2
-
-
... More
Supply MCCB of 160 Amps, 4 pole, 36 KA, AC supply 50Hz, 415 V complete all as specified and directed.
2
-
-
... More
Supply MCCB of 100 Amps, 4 pole, 36 KA, AC supply 50Hz, 415 V complete all as specified and directed.
2
-
-
... More
Supply MCCB upto 63 Amps, 4 pole, 36 KA, AC supply 50Hz, 415 V complete all as specified and directed.
5
-
-
... More
Supply Power contactor 32 Amps, 3 pole, 415 V complete all as specified and directed.
3
-
-
... More
Supply and fix rubber insulating mat in front of LT panel board of size 3 mm thick, 1 m width up tp 3.3 KV all as specified and directed.
10
-
-
... More
Supply digital electronic Ammeter (0-100 amps range) with built in selector switch suitable for LT 415 V panel flush pattern square type 96 mm x 96 mm with adopter complete all as specified and directed.
2
-
-
... More
Supply digital electronic Volt meter (0-500 volts range) with built in selector switch suitable for LT 415 V panel flush pattern square type 96 mm x 96 mm with adopter complete all as specified and directed
2
-
-
... More
Supply indication lamps (LED type) red, yellow and blue in colours of 22.5 mm dia to monitor on LT panel board suitable for 240 V AC supply and taking down unserviceable indication lamps all as specified and directed.
3
-
-
... More
Supply and fix pressure gauge for suction/discharge refrigerant lines and water lines of square/round type 2"/4" dial of following ranges for Package/Central type AC plants including taking down old unserviceable pressure gauge complete all as specified directed
-
-
-
... More
0-150 PSI for refrigerant line
5
-
-
... More
0-300 PSI for refrigerant line
5
-
-
... More
0-12 Kg./cm2 for water line
5
-
-
... More
Earthing complete with copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to 20×3mm copper strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
5
-
-
... More
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3mm copper strip complete all as specified and directed.
36
-
-
... More
Labour only for attending electrical breakdowns checking the serviceability, testing, replacement of minor spare parts in starters,panels,pumps, making the unit completely functional complete all as specified and directed by Engineer-in-Change :- Note - The quoted rate is deemed to be include (i) necessary T&P to attend the breakdown. (ii) Necessary labour/trade men for attending emmergency break down . (iii) labour element and spares required for making the unit completely functional such as control wiring,terminal bolts copper cables,lugs etc. (iv) PCC work wherever required
40
-
-
... More
Labour only for attending break down of pipe line of upto 150mm bore, bursting/cracks and including cleaning/removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes MS/CI collar etc as per site requirement, testing and arresting leakages of lead joints, testing and necessary dewatering by using necessary pumps, mechanical excavator complete all as specified and directed by engineer-in-change for the following :- Note :- The quoted rate is deemed to be include (i) arrangement of suitable pump sets for dewatering at the time of breakdown. (ii) Necessary labour/trade men for attending emmergency break down . (iii) labour element required for fixing CI/DI/MS pipes, specials fittings (iv) All earth work to carry out manually as well mechanical excavator and keep mechanical excavator stand by till completion of work
45
-
-
... More
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket along with gi pipe 1.5rm not less than 25mm with impact and corrosion resistant including thermalmanagement in multiple optics complete with IP 65/66 protection complete.
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%