Military Engineer Services Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Military Engineer Services - MES Tender
Civil And Construction
Eprocure
Opening Date24 Feb 2024
Closing Date2 Apr 2024
Tender Amount₹ 1,48,70,000
Costs
EMD
₹ 2,23,700Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_643382_1Bid Award Id
ViewTender No
82415/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M & L for providing two coats of ready to use two components polymer modified cementitious coating [SikaTopcoat 107 or Aqua Arm Top Guard of SIKA/ Brushbond of FOSROC/ Elasplast ROL 10 Mucis of THERMAX/ Shalicem Abra of STP or equivalent chemical in makes specified herein after in Particular Specifications]on walls and floors inside of water tanks complete all as per manufacturer's instructructions, as specified and as directed. Note: First Coat should be applied horizontzlly and second coat should be applied vertically. The overall thickness of coating shall not be less than 1.5mm.
2150
-
-
... More
M & L for providing two coats of water based epoxy coating certified for portable water [Sikagard 67 or Aqu Arm Tank Coat of SIKA/ Nitokote EP 405 of FOSROC/ T Grout EC 200 of THERMAX/ Tankmastic of STP or equivalent chemical in makes specified herein after in Particular Specifications]on all over the internal reinforced cement concrete surfaces of water tanks complete all as per manufacturer's instructructions, as specified and as directed. Note: The Thickness after two coating shall not be less than 500 microns. The coating shall be applied using brush. First Coat shall be allowed to dry for 6 to 8 hours and then second coat shall be applied and allow it to cure complete 24 hrs.
2150
-
-
... More
Demolition/ removing of existing unsound/ weak/ loose concrete including concrete around the rusted reinforcement bars upto required depth by low impact high frequency hammer/ chipper without damaging the sound concrete, in straight line geometrical forms, grooving the edges with grinder upto 5 -10 mm depth without damaging existing rebars, carefully removing and stacking of debris at prescribed location as directed, disposing off the debris outside the MoD land complete all as per manufacturer's instructructions, as specified and as directed. Note: Before demolition/ removing of existing concrete members proper examination of surfaces shall be conducted to identify the loose concrete areas of structural elements by tapping with light hammer without any disturbance to the adjoining sound concrete elements.
1025
-
-
... More
M&L for providing two component solvent free ready to use epoxy bonding agent [Sikadur 32LP or Re Arm Superbond of SIKA/ Nitobond EP of FOSROC/ TM Bond EP of THERMAX or equivalent chemical in makes specified herein after in Particular Specifications]for bonding old concrete to new concrete applied over old concrete using brush including necessary preparation of surface removing of all dust or latiance and cleaning the surface complete all as per manufacturer's instructructions, as specified and as directed. Note: The material shall have the following properties:-
[a] Compressive strength 50 N/mm2 at 7 Days [b] Flexural strenght 35N/mms at 7 Days [c] Shear strength ION/mm2 at 7 Days [d] Tensile strength 20 N/mm2 [e] Bond Strength of ION/mm2.
1025
-
-
... More
M&L for cleaning the existing rusted reinforcement bars with wire brush/ rotary wire brush to make surface free from rust scales, loose material, dirt, etc. including providing and applying two coats of alkaline rust converting primer [Sika Rust Off 100 or ReArm Rust Remover of SIKA/ Reebahen SRR of FOSROC/ Maxcure RR of THERMAX/ Shalifix FRM CI of STP or equivalent chemical in makes specified herein after in Particular Specifications] with brush and complete wetting of rusted metal surface and allowed to react for 16-24 hours to form a protective white layer which will protect further corrosion of metal / steel for about 5-7 days complete all as per manufacturer's instructructions, as specified and as directed.
1025
-
-
... More
M&L for providing and applying two component cement based polymer modified ready to use passivator/ anti corrosion coating [Aqua Arm Coat ZP of SIKA/ Nitocoat AP35 of FOSROC/ Maxcure 10 of THERMAX/ Shalikote AC of STP or equivalent chemical in makes specified herein after in Particular Specifications] compatible with the reinstatement methods adopted to the steel reinforcement for corrosion protection including necessary preparation of surfaces with wire brush and thoroughly cleaned for dust with dry cloth complete all as per manufacturer's instructructions, as specified and as directed.
1025
-
-
... More
M&L for Drilling of holes to a size upto 25 mm dia and upto 160mm deep including fixing of reinforcement bars inside the drilled hole by applying thixiotropic epoxy adhesive [SikaDur 31 of SIKA/ Conbextra EP 100 of FOSROC/ Maxflex PU-I of THERMAX/ Shaligrout EI of STP or equivalent chemical in makes specified herein after in Particular Specifications]to ensure complete sealing of the reinforcement bars and allowed to cure complete all as per manufacturer's instructructions, as specified and as directed. Note: Reinforcement bars shall be measured and paid separately under respective item of this BoQ.
175
-
-
... More
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
500
-
-
... More
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 5mm to 10mm dia bars as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
240
-
-
... More
M & L for providing 25mm average thick single component, fibre reinforced, sulphate resistant, low shrinkage, high performance cementitious structural repair mortar [MonoTop @- 122F of SIKA/ Renderoc SP 40 of FOSROC/ BS 5F of THERMAX or equivalent chemical in makes specified herein after in Particular Specifications] as in rebuilding the section of damaged RCC elements to its original size, applied by hand or mechanical spraying including use and removal of suitable steel structural form work complete all as per manufacturer's instructructions, as specified and as directed.
745
-
-
... More
M&L for providing 40-100mm thick ready to use non shrink, cemetitious free flow micro concrete [SikaRep Microcrete-4 of SIKA/ Renderoc RG Spl of FOSROC/ BS 66 MuCIs of THERMAX or equivalent chemical in makes specified herein after in Particular Specifications]as in rebuilding the section of damaged RCC elements to its original size having compressive sterngth 60 N /sq.mm (28days) according to ASTM including use and removal of suitable steel structural form work complete all as per manufacturer's instructructions, as specified and as directed.
13.5
-
-
... More
M&L for providing and wrapping stitched one directioal, high strength low density Carbon Fiber Reinforced Polymer [CFRP] fabric base [SikaWrap230C of SIKA/Nitowrap GW of FOSROC/ Maxtreat Fibernet C of THERMAX or equivalent chemical in makes specified herein after in Particular Specifications] in single layer over columns, tie beams and girders at desired orientation using tamping rollers to avoid any air voids, etc. over a coat of thixotropic epoxy based resin impregnating resin/ adhesive [Sikadur-330(IN) of SIKA/Nitoplane CPS of FOSROC/ Maxtreat Glue of THERMAX or equivalent chemical in makes specified herein after in Particular Specifications] over a coat of epoxy primer and sprinking sand over it as directed by Engineer -In -Charge including providing thixotropic epoxy based impregnating resin/adhesive as specified above as in top coat over wrap including necessary surface preparation of existing concrete elements by rounding off sharp edges to 25mm radius and removal of dust and foriegn materials and cleaning properly complete all as per manufacturer's instructructions, as specified and as directed.
450
-
-
... More
M&L for 15 mm thick plaster on SikaWrap230C covered surafce in cement mortar 1:4 mixed with approved integral water proofing compound as per manufacturer's instructions complete all as specified and as directed.
450
-
-
... More
M & L for providing and applying Two coats of two components ready to use polymer modified cementitious coating [Aqua Arm Top Guard of SIKA/ Brushbond of FOSROC/ Elasplast ROL 10 Mucis of THERMAX/ Shalicem Abra of STP or equivalent chemical in makes specified herein after in Particular Specifications] on the roof not less than 1.5mm overall thickness over 25mm thick PCC 1:2:4 admixed with bonding agent [Aquaarm WP-10 or sika latex SBR of SIKA/ Nitobond SBR Latex of FOSROC/ TM Bond AR of THERMAX/ Shali SBR Latex of STP or equivalent chemical in makes specified herein after in Particular Specifications] including necessary surface preparation of existing concrete surfaces and removal of dust and foriegn materials and cleaning properly complete all as per manufacturer's instructructions, as specified and as directed. Note: First Coat should be applied horizontzlly and second coat should be applied vertically as directed.
50
-
-
... More
S&F in repairs Dial type water level indicator of size 3 feet dia, 15 feet capacity, suitable for overhead reservoirs/ Uner ground sump, Dial made of 22 gauge GI casing, dust proof, finished with 2 coats of Zibcoxide and 2 coats of water proofing paint, with 4 mm thick glass, rubber beading center pointer with locking nylon line including counter weight, SS float etc., including testing and commissioning complete all as specified and as directed.
6
-
-
... More
Notes for Serial Item No. 1 to 18: [a] The rate quoted for respective items shall be deemed to be inclusive of all material, labour, expert supervision, Tools, Plant, Safety measures like safety belts, ropes, helmets, netting etc. required to work at any height as per site requirement and providing double scaffolding and as required and removal of the same on completion of the comprehensive repairs and disposal and depositing the demolished material out of MD land complete all as specified and as directed.
[b] 06 Nos. of Photographs of Overhead Water Tanks before and after Repairs shall be submitted to GE for record before claiming payment. [c] Sample testing of every Overhead Water Tank before and after Repairs from NABL Accredited Laboratory for Microbial parameters of water shall be submitted to GE for record before claiming payment.
-
-
-
... More
[d] The Structural repair works shall be got executed directly by the Manufacturer or through their authorised applicator. The contractor shall obtain a written guarantee for the effectiveness of the structural repairs carried out to the Overhead Water Tanks from the manufacturer and shall be submitted to GE for record before claiming payment. The manufacturer shall also certify that the structural repairs of the Overhead Water Tanks have been carried as per the standard engineering practices and also certify the strength and serviceability of the Overhead Water Tanks.
[e] The rates quoted shall be deemed to include all necessary form work required for providing concrete/ mortar for rebuilding the damaged RCC members.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements