Military Engineer Services Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date26 Oct 2024
Closing Soon26 Nov 2024
Tender Amount₹ 4,30,000
Costs
EMD
₹ 8,600Document Cost
₹ 300Tender Fee
Refer Documents
Summary
Repairs To Misc E/m Works To Certain Buildings During Gwfr Exercise At Af Stn Suryalanka
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681502_1Tender No
AGE(I)/SL/8641Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
S&F in repairs modular switch socket combination 16A, 6 pin, 3 module complete all as specified and as directed.
15
-
-
S&F in repairs modular switch one way 6 Amps, 1 module complete all as specified and as directed.
30
-
-
S&F in repairs of Modular Bell Push 6/10 Amps, 01 Module complete all as specified and as directed.
5
-
-
S&F in repairs of modular Fan regulator electronic step type, 120W- 2 module, 240V single phase complete all as specified and as directed.
5
-
-
S&F in repairs flush type switch socket combination 5A, 2 in one , complete all as specified and as directed.
15
-
-
S&F in repairs flush type switch socket combination 16A, 3 pin, complete all as specified and as directed.
10
-
-
S&F in repairs socket 2 in 1, 3 pin, 6 Amp flush type universal complete all as specified and as directed.
5
-
-
S&F in repairs switch flush type one way 6 Amps, complete all as specified and as directed.
15
-
-
S&F in repairs of stepped type electronic Fan regulator flush type , 120W 240V single phase complete all as specified and as directed.
5
-
-
S&F in repairs of flush type Bell Push 5/6 Amps, complete all as specified and as directed.
5
-
-
S&F in repairs of 230 Volts, AC, Bell Ding-Dong complete all as specified and as directed.
8
-
-
S&F in repairs modular white cover plate with frame and metal flush box, 3 module complete all as specified and as directed.
20
-
-
S&F in repairs modular white cover plate with frame and metal flux box, 6 module complete all as specified and as directed.
6
-
-
S&F in repairs modular white cover plate with frame and metal flush box, 12 module complete all as specified and as directed.
3
-
-
S&F in repairs ceiling rose, 3 plate PVC/polycarbonate, isolated body complete all as specified and as directed.
10
-
-
S&F in repairs submain wiring with two run of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 4 Sqmm copper multistranded conductor including and drawing into concealed/Surface PVC conduit, making good with chasing, chipping, applying cement, fixed on/in wall, ceiling including 4 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth complete including taking down existing submain wiring complete all as specified and as directed.
40
-
-
All as per Item No.19 but with 6 sqmm copper FRLS cable
30
-
-
S&F in repairs LED Bldg light fitting with and including individual high power 25 watt, efficiency not less than 110LM/W LED new generation energy saving and environmental friendly long life LED street light made up of pressure die cast alu with secondary optics, suitable for outdoor use IP 66, fixed on Wall/ Pole, connected with connecting cable, making good distrubed surface complete all as specified and as directed.
2
-
-
S&F in replacement of MCB, SP 6-32 Amps, C Curve, 10 kA, Complete all as specified and as directed.
5
-
-
S&F in replacement of MCB, SPN 6-32 Amps, C Curve, 10 kA, Complete all as specified and as directed.
5
-
-
S&F in replacement of MCB, Four Pole 40 - 63 Amps, C Curve Complete all as specified and as directed.
2
-
-
S&F in replacement of MCB, Three Pole 40 to 63 Amps, C Curve Complete all as specified and as directed.
2
-
-
S&F in repair MCB DB Double Door, SPN 8 way IP 54, fixed to wall in concealed by distrubing the exisitng wall surface and making good complete all as specified and as directed.
1
-
-
S&F in replacement two pin and earth Metal clad plug and socket with MCB SP 20Amps, complete all as specified and as directed.
2
-
-
S&F 4 Feet LED Tube light of 20 Watt Batten with integrated electronic driver having THD 20% and aluminium housing with necessary fixing screws, and connected upto ceiling rose including taking down exisitng Tube light fitting of any type and making Good complete all as specified and as directed.
50
-
-
S&F 2 Feet LED Tube light of 10 Watt Batten with integrated electronic driver and aluminium housing with necessary fixing screws, and connected upto ceiling rose including taking down exisitng Tube light fitting of any type and making Good complete all as specified and as directed.
50
-
-
Taking down ceiling fan/ Exhaust fan/ wall monted fan/ pedestal fan of any make and sweep, cleaning externally and internally. Stripping out the fans, examine the unserviceable spares/ burnt winding by testing, cleaning and lubricating bush/ bearings. Refixing the fan to any location and position after necessary works/ servicing including carring out the replacement worn out parts, body covers, screws, spilt pins nuts condensor and flexible wire copper conducter from ceiling fan to ceiling rose etc complete all as specified and directed. Note:- (i) The parts replaced will be measured by relevant item as supplied only.
60
-
-
Removing defective winding of any type / sweep of ceiling fan and rewinding with new super enamelled copper wire of existing gauge and weight as per manufactures design and instructions including insulating materials and varnishing of ceiling fans of any make and re-assembling testing complete including replacement of shaft as per existing manufactures design,replacement of ceiling fan terminal connector, replacement of flexible copper wire from ceiling rose to ceiling fan complete all as specified and directed.
60
-
-
Supply only following spare parts of ceiling fan of 1200mm/ 1400mm sweep of different make required as per the makes of existing fans as required at site or in winding shop complete all as specified and as directed.
-
-
-
Rubber bush for shackle with bolt, nut, washers and lock pin suitable for Ceiling fan 1200mm/ 1400mm sweep complete all as specified and directed
45
-
-
Ball bearing of size No. 6201/6202/ 6203 suitable for ceiling fan / exhaust fan complete all as specified and as directed.
Make:- SKF/ NBC/NTN/ ZKL/ Koyo/ Tata/ RHP
15
-
-
S&F in replacement condenser (capacitor) 3.15/ 2.5 MFD, 220 Volts, AC, 50 Hz as per IS : 1709 suitable for ceiling fan 1200/ 1400mm sweep complete all as specified and as directed.
Make:- Tibcon/Ducati/ Keltron/ Crompton / Bajaj / Concap/ ABB
50
-
-
S&F in replacement condenser 4 MFD, 220 Volts, AC, 50 Hz as per IS : 1709 suitable for exhaust fan 300/ 380/ 450 mm sweep complete all as specified and as directed.
Make:- Tibcon/Ducati/ Keltron/ Crompton / Bajaj / Concap/ ABB
8
-
-
M&L for repair/ replacement of heater element of 1.5 kw suitable for geyser of capacity 15 to 25 Ltr as per exisiting model complete all as specified and as directed.
1
-
-
M&L for repair/ replacement of Thermostat suitable for geyser of capacity 15 to 25 Ltr as per exisiting model complete all as specified and as directed.
1
-
-
Taking down the following existing worn out spares of Split type Air conditioners 1.5 Ton / 2.0 Ton capacity; supply and fix in repair new spares of make and model complete all as specified and directed:-
-
-
-
Blower Motor Indoor Type (Make : Hitachi/ Carrier/ Voltas/ Samsung)
2
-
-
Fan Motor Out door Type/ window type without blades (Make : LG/ Carrier/ Voltas/ Samsung)
3
-
-
Starting Capacitor 35 to 45 MFD (Make: Tibcon/Ducati/ Keltron/ Concap)
15
-
-
Running Capacitor 50 to 60 MFD (Make: Tibcon/Ducati/ Keltron/ Concap)
15
-
-
Outdoor Fan Motor Blade for 1.5 TR/ 2.0 TR
3
-
-
PCB Timer electronic switch with sensor suitable for all makes (Non Inverter type) of split 1.5 / 2 Ton AC complete with hand set including taking down unserviceable Electronic PCB from existing unit all as directed.
10
-
-
PCB Timer electronic switch with sensors suitable for all makes (Inverter Type) of split 1.5 / 2 Ton AC complete with hand set including taking down unserviceable Electronic PCB from existing unit all as directed.
10
-
-
Sensor for split ac with connecting wires
10
-
-
Contactor for Split AC
15
-
-
Brass coupling nuts for copper tubes of split ac of any size
10
-
-
M&L for Top up / Gas charging with refrigerant gas (R-22/32/410) for Air conditioner window type / split type of capacity 1.5 / 2 Ton after vacuuming & leak testing including bracing suction/discharge line and testing complete all as specified and as directed.
45
-
-
Supply & fix in replacement copper tubing suction and liquid line from Indoor to out door unit suitable for Split A/C 1.5 TR / 2 TR including insulation on copper tubing complete all as specified and as directed.
35
-
-
Taking out unserviceable Rotary type compressor of Split type AC 1.5 ton capacity and re-fixing with new Rotary type compressor sealed unit in position, charging of refrigerant gas R-22 of required quantity, bracing of discharge and suction line and leak testing complete all as specified and as directed. Make: Tecumseh/ Highly/ Voltas/ Hitachi/ Carrier/ Bluestar
2
-
-
All as per item No 40 above but of 2 Ton capacity.
2
-
-
Opening the indoor unit front panel of wall mounted split type 1.5/ 2 Ton AC for cleaning /Servicing the existing LDPE pipe/ Filter for any blockage by blowing the pipe with air and cleaning the bottom water line of indoor unit for arresting leakage of water including Connecting with necessary PVC PIPE of suitable to Drain out water outside the room (Pipe length not more than 3 m) complete all as specified and as directed.
15
-
-
Taking down existing split type AC 1.5 / 2 ton (Including Stand of outdoor and indoor ) from one location and re-fixing the same in another location as directed, including necessary fixing arrangemnts like screw,bolts,brazing,Gas filling etc..and for connecting IDU & ODU, cleaning the IDU and ODU for smooth functioning and testing, complete all as specified & directed.
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%