Military Engineer Services Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Military Engineer Services - MES Tender
Civil And Construction
Electrical and Electronics
Eprocure
Opening Date31 Aug 2024
Closing Date12 Sep 2024
Tender Amount₹ 9,62,000
Costs
EMD
₹ 19,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_669321_1Bid Award Id
ViewTender No
AGE(I)/SL/8617Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L for screed bed in CM (1:4), 15 mm thick in floor.
22
-
-
M & L Acid resistant tiles 15mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, in floor
22
-
-
Glazed ceramic tiles (200x200mm) x 7mm thick, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
1.9
-
-
M&L 20-25 mm thick machine cut kota stone slab as in window Cill, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, all as specified and as directed by Engineer-in-Charge.
0.51
-
-
M&L for pressed steel frames of size 125 X 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete as specified supplied and fixed
5
-
-
S & F 30 mm thick Flush shutters, solidcore construction, with block oard core and ply wood face panels, commercial type on both sides all as specified and directed
2.1
-
-
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel
peg stay, complete with glazing bars, dovetailed or welded
2.4
-
-
S & F 4.8 mm thick Sheet glass, ordinary quality
and glazing with oil putty in square n exc 0.5 sq. m in each pane
2.4
-
-
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper of approved shade/tint over a coat of alkali resistance primer on walls and as directed by eingineer in charge
81
-
-
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint a coat of primer all as specified and directed.
89.28
-
-
M&L Preparing new or previously un treated surfaces of wood and wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer all as specified and directed.
4.2
-
-
S&F 150 mm long Aluminium alloy handles cast type anodised all as specified and directed.
2
-
-
S&F 200 mm long Aluminium anodised barrel tower bolts of extruded aluminium section fixed in repairs all as specified and directed.
2
-
-
S&F 300mm long aluminium alloy anodised sliding door bolts with hasp & staple (bolt type) and fixing clip of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified and directed.
1
-
-
S&F rolled mild steel in roof trusses (framed) Fe-290 (Gde-E-165), trussed, purlins, crane gantries, rails and fastenings and heay bracket framing (beam, tee, angle, channel of flat sections) including distance pieces, cleats etc complete all as spd and as directed.
103.65
-
-
Supplied and fixed pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws etc complete all as specified, directed and as per manufacturer's instructions.
41.82
-
-
M&L for preparing new or previously untreated surfaces of steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide,zinc chrome primer all as specified and directed.
3.9
-
-
S&F Anodised aluminium snap grid frame work for false ceiling all as specified
22
-
-
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
22
-
-
S&F PVC insulation panels (10 mm thick) with EPS stuck to 1mm printed PVC sheet suitably placed in false ceiling grid made of Aluminium /G.I./M.S. as per specification and drawing
22
-
-
Excavating over areas, n exc 1.5 m deep and getting out
71.67
-
-
Removing excavated material (soil) to a distance exc. 250 metre but not exc 500 metre and depositing where directed at a level not exceeding 1.5 metre above the strating point.
71.67
-
-
Supply and laying Moorum / red bajri spread, rolled and consolidates to gradient and camber required 100mm thick all as specified.
15.93
-
-
M & L Hardcore of gauge exc 63 mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface
23.89
-
-
M&L for Cement concrete work in pavement / hard standing of flexural strength 40 Kg/ square centimeter in field, using 400 Kg of cement per Cum thickness of concrete 25 cm or less including use of form work all as specified and directed.
31.85
-
-
M&L forming contraction (Dummy) joints 65mm deep 10mm wide, filled with sealing compound, grade `A' complete all as specified and as directed.
7.94
-
-
M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross-sectional area, single core PVC insulated (FRLS), unsheathed multistranded copper conductor cable 1100 Volts grade drawn through and including rigid non-metallic PVC concealed conduit not lessthan 20mm dia medium grade and accessories ISI marked and suitable modular pressed steel terminal boxes 1.6mm thick (recessed), sockets etc including 1.5 Sqmm nominal cross sectional area, single core PVC insulated (FRLS), unsheathed multistranded copper conductor cable earth continuity wire to common earth and connected to earth dolly for one light / fan/ Security light/ 5Amps Indp Socket / Bell point controlled by one switch complete all as specified and directed
6
-
-
All as per Item No. 30 above but one 3 pin socket outlet, 5 amps on same boared
1
-
-
All as per Item No. 30 above but one 3 pin socket outlet, 15 amps controlled by one switch on independent board with 4 sqmm size cable for Phase, neutral and earth.
5
-
-
S&F of Switch 5/6 Amps, 1module 1 Way complete all as specified and as directed.
7
-
-
S&F of Modular Switch 15/16 Amps, 1 Module 1 Way complete all as specified and as directed.
5
-
-
S&F of Modular Socket 5/6 Amps, 2 Module 2 and 3 pin complete all as specified and as directed.
3
-
-
S&F of Modular Socket 15/16 Amps, 2 Module 2/3 pin complete all as specified and as directed.
5
-
-
S&F of Modular Fan Regulator Step type, 2 Module 120W complete all as specified and as directed.
2
-
-
S&F of 3 Module Cover Plate with frame and Metal Flush Box complete all as specified and as directed.
7
-
-
S&F of 8 Module Cover Plate with frame and Metal Flush complete all as specified and as directed.
1
-
-
S&F 12 Module Cover Plate with frame and Metal Flush complete all as specified and as directed.
1
-
-
S&F of Ceiling rose, 3 plate /PVC/ polycarbonate, isolated body complete all as specified and as directed
4
-
-
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete
2
-
-
S&F LED Bldg. Security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
2
-
-
S&F street light brackets made of 25 mm dia G.I. Pipe light grade in shape and angle as directed not exceeding 1.5 mtrs in length fixed to wall with suitable size of M.S. flat iron clamps, M.S nut & bolt with cup washers, painting to MS material with anti corrisive paint complete all as specified and as directed.
2
-
-
Supply and fix ceiling fans, min 3 Star rated ,complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor, Including making necessary arrangements for fixing of ceiling fan like hook etc. complete all as specified and as directed.
2
-
-
S&F SPN DB Double door 8 way with tray for provision of MCBs, and Dolly for earth and netural complete all as specified and as directed.
1
-
-
S&F SPN DB Double door 4 way with tray for provision of MCBs, and Dolly for earth and netural complete all as specified and as directed.
1
-
-
S&F MCB TPN 40- 63 Amps, 10 kA, C Curve complete all as specified and as directed.
2
-
-
S&F MCB SPN Pole 6-32 Amps, 10 kA, C Curve complete all as specified and as directed.
2
-
-
S&F MCB Single Pole 6-32 Amps, 10 kA, C Curve complete all as specified and as directed.
4
-
-
S&F of submain wiring with two run of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 4 Sqmm copper multistranded conductor including and drawing into concealed PVC conduit of suitalbe size ISI marked Medium grade, fixed on/through wall, ceiling including 4 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth complete all as specified and as directed.
25
-
-
S&F in replacement submain wiring with Four run of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 6 Sqmm copper multistranded conductor including and drawing into concealed PVC conduit of suitalbe size ISI marked Medium grade, fixed on/through wall, ceiling including 6 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth complete all as specified and as directed.
20
-
-
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of 4.0 core 25 Sqmm
110
-
-
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of cable n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft / loose soil complete all as specified and as directed.
27
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
14.61
-
-
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
12.39
-
-
S&L Sand filling for cable protection above and below cable and rammed down complete all as specified and as directed
8.1
-
-
S&L Red Bricks common burnt clay building bricks, sub-class ‘B’ designation 75 complete all as specified and as directed.
800
-
-
S&L GI pipe light grade for cable protection with clamps of size not less than 40 mm dia complete all as specified and as directed.
8
-
-