Indian Navy Tender

... More
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Indian Navy Tender

Goods
Security and Emergency Services
GEM
Opening Date27 Jan 2025
Closing Date4 Mar 2025
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Carry out hydrostatic pressure test of halon cylinders. If satisfactory clean and dry the cylinders. Paint as per approved paint scheme. Mount the assembly unit of bottles. Fill few kilograms of halon in the bottles and charge with N2 at 42 bar. Check for leaks. If satisfactory, charge the halon and N2 as per manufacturers recommendations. Reinstall onboard. Carry out check as required.

46

-

-

... More
Remove and send halon bottles ashore ( with special mountings, protective caps mounted on halon valves). Transfer halon into reserve halon cylinder if the laboratory analysis of the halon is satisfactory. Dismantle halon bottles into components. Inspect and carry out general overhaul. Refit/renew the components in assembly with halon bottles as required.

46

-

-

... More
Replace the cartridge in the Electro Pneumatic Actuator.

16

-

-

... More
Comprehensive audit of Main Control panels to be undertaken. Inspect all PCBs/ electrical parts of Control Panel for serviceability

4

-

-

... More
Replacement/ Overhaul of nozzles

16

-

-

... More
Carry out servicing and proof testing of the Halon . Recharge as per manufacturer’s recommendation and re-install onboard.

46

-

-

... More
Calibrate all pressure gauges and Pressure switches

230

-

-

... More
Check and calibrate safety relief valve, manifold bypass valve, manifold pressure switch fitted on manifold.

26

-

-

... More
Removal weighing and refitment of Halon bottle

308

-

-

... More
Removal weighing and refitment of Pilot bottle

126

-

-

... More
Overhauling of cylinder bottle valves along with requisite spares cylinder bottle valve includes mechanical and pneumatic actuators

46

-

-

... More
Overhauling of directional valves, along with spares

12

-

-

... More
Overhauling of Pilot cylinder valves along with spares

18

-

-

... More
Pressure testing and charging of Nitrogen pilot cylinders and filling nitrogen

18

-

-

... More
Undertake Ultrasonic Gauging Testing. per bottle (halon)

46

-

-

... More
Undertake Radiography of Halon Bottles. per Bottle (Halon)

46

-

-

... More
Removal and Refurbishment of Remote annunciation panels

26

-

-

... More
Repair / Routine maintenance of complete indication and Alarm system

4

-

-

... More
Testing of halon from authorised Laboratory

46

-

-

... More
Borescope Inspection of Halon bottles followed by pressure testing upto standard testing pressure

46

-

-

... More
Undertake replacement of Bottle head assemblies with new one (including new BHA)

16

-

-

... More
Undertake replacement of NRV (Including new NRV)

46

-

-

... More
Rectify defect of ventilation crash stop not working

4

-

-

... More
Undertake replacement of Hooter (Including new hooter)

26

-

-

... More
Undertake repalcement of Flash Light (Including new Flash light)

26

-

-

... More
Repair / replacement of solenoid actuators

26

-

-

... More
SPARES

-

-

-

... More
Check Valve 1.25"

26

-

-

... More
Connection Hose

16

-

-

... More
Manifold 4" Dia x 2.6 M

16

-

-

... More
Pressure Switch on manifold for Discharge per build up Alarm

4

-

-

... More
Trip Block

4

-

-

... More
Connection Elbow (As required)

46

-

-

... More
Pr. Operated Directional Valve 2" Dia

4

-

-

... More
Pilot Cylinder with N2 Gas & Pr. Gauge & Pr. Switch for Low Pr. Alarm

4

-

-

... More
Manual Actuator with Position Spring Assy

16

-

-

... More
Pneumatic Actuator with Position Spring Assy

4

-

-

... More
Control Box

4

-

-

... More
Flashing Lamp (Red)

26

-

-

... More
Pr. Relief Valve-3/4"

26

-

-

... More
Non-Return Valve-1/4"

46

-

-

... More
Electric Cable

26

-

-

... More
24V DC power 'ON' Lamp (Green)

26

-

-

... More
Lamp for indication of Halon leakage or inadvertant discharge into manifold

26

-

-

... More
Lamp for indication of pressure

26

-

-

... More
Audio Visual Alarm-cum-Relays Panel in DCHQ

4

-

-

... More
High intensity Flashing Lamp (Red)

26

-

-

... More
Push Button for Audio Visual Alarm Test

26

-

-

... More
Lamp for indication of Halon leakage or inadvertant discharge into manifold

26

-

-

... More
Lamp for indication of pressure build up in manifold

26

-

-

... More
Pressure Relief Valve

26

-

-

... More
By pass Valve

26

-

-

... More
Non-Return Valve at the discharge side of Relief Valve

26

-

-

... More
12V X 7 Plates Battery

26

-

-

... More
Electric Pneumatic Actuator

26

-

-

... More
Single Shot Cartridge

26

-

-

... More
Indicator Valve

26

-

-

... More
Indicator Cap

26

-

-

... More
Indicator Disc

26

-

-

... More
Non-Return Valve

26

-

-

... More
Pipe key E Activator

26

-

-

... More
Lock Safety

26

-

-

... More
Halon 1301 Cylinder

4

-

-

... More
Pressure Manual Release Head

46

-

-

... More
Electrical Manual Release Head

46

-

-

... More
Pressure Operated Main Valve

4

-

-

... More
Control Head C/W Safety & reset Pin

46

-

-

... More
Manual Push Button

12

-

-

... More
Solenoid Valve, 24V DC Flameproof

12

-

-

... More
Pilot Tube

26

-

-

... More
Pressure Switch

12

-

-

... More
Pressure Gauge 0-250KG/CM2

46

-

-

... More
Flameproof Bell, 24V DC

12

-

-

... More
Test lamp

26

-

-

... More
PILOT LAMP D1461

26

-

-

... More
Luminous Key

26

-

-

... More
Lamp cap

26

-

-

... More
Safety cover

26

-

-

... More
Electric horn

12

-

-

... More
Fuse 0.25 amp for release print

26

-

-

... More
Fuse 2 amp

26

-

-

... More
Pressure switch/pressure gauge unit

26

-

-

... More
Flexible hose

46

-

-

... More
Pneum actuator

16

-

-

... More
Manual/Pneum. Actuator

16

-

-

... More
Press. Operated switch

26

-

-

... More
Ball valve 1/4"

46

-

-

... More
Non return valve DN 40

46

-

-

... More
Non return valve DN 50

46

-

-

... More
Non return valve DN 80

46

-

-

... More
Pr operated cyl valve

46

-

-

... More
Venting valve

26

-

-

... More
Leak detector

26

-

-

... More
Elc pneumatic actvator

16

-

-

... More
Cap F. actutator

26

-

-

... More
Halon nozzle 3/8"

26

-

-

... More
Halon main valve DN 80

16

-

-

... More
Relay K2

4

-

-

... More
Pressure switch for N2 bottle

26

-

-

... More
40mm Manifold check valve

26

-

-

... More
Actuation (Pneumatic) line check valve

26

-

-

... More
Manifold pressure relife valve

26

-

-

... More
Control panel

4

-

-

... More
Push botton station

26

-

-

... More
Halon discharge nozzle

26

-

-

... More
1/4" Actuation hose with both end 7/16" unf union couplings 14 " long

26

-

-

... More
Actuation bleed vent valve

26

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.