Hindustan Shipyard Limited Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Hindustan Shipyard Limited - HSL Tender

Works
Civil And Construction
Eprocure
Opening Date9 Dec 2023
Closing Date8 Feb 2024
Tender Amount₹ 3,76,00,00,000 
Notes
Download

Costs

Summary

Upgradation Of Slipway, Construction Of Crane Track And Allied Services Like Drainage System, Signages, Upgradation Of Mep Services, Gas Utilities, Firefighting Systems, Supply And Erection Of Goliath Crane, Machinery Etc. For The Augmentation Of Sli

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
VOL II - Technical Specification
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Clearing the jungle including uprooting of rank vegetation, grass, brushwood, trees and saplings of girth upto 30 cm measured at 1m height from ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.

394

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. as directed by the Engineer-in-Charge.

-

-

-

... More
All kinds of soil

786

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed, as directed by the Engineer-in-Charge

-

-

-

... More
All kinds of soil.

25777

-

-

... More
Extra for every additional lift 1.5m or part there of in excavation / banking excavated or stacked materials

-

-

-

... More
All kinds of soil

4102

-

-

... More
Extra rates for quantities of works,earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed In or under water and/or liquid mud, including pumping out water as required for excavation in gullet area to facilitate the cutting of exisiting piles to the required depth.

410

-

-

... More
Supplying and filling in plinth/areas with sand under floors, including watering, ramming, consolidating and dressing complete.

956

-

-

... More
Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m including cost and conveyance of all materials,labour charges,lead,lift etc complete at all levels as per direction of Engineer-in-charge.

2769

-

-

... More
Filling available excavated earth(excluding rock) in trenches, under floors,plinth,sides of foundation,in areas etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering,lead upto 50m and lift upto 1.5m including cost and conveyance of all materials,labour charges, etc complete at all levels as directed by the Engineer-in-Charge

11939

-

-

... More
Soling with soling stone of size 150 to 75 mm brokenstone and binding materials, including hand packing and wedging them tightly so that the whole is formed as a solid mass, spreading binding material in 12mm thick layers and sweeping the same to fill the voids,watering profusely and consolidating with hand rammer/ plate vibrator etc complete as per the direction of Engineer-in - Charge.

105

-

-

... More
Disposal/ Stacking of surplus excavated earth / rock/ building rubbish / malba / similar unserviceable,dismantled or waste materials by mechanical means, including loading, transporting, unloading to outside the premises/ approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.

9688

-

-

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the slipway filled area in required thickness, for all leads & lifts, under floors, including watering, ramming, consolidating and dressing complete.all complete as per direction of Engineer-in-charge.

20218

-

-

... More
Pile work

-

-

-

... More
Arranging and conducting vertical load testing of piles in accordance with IS.2911 (Part IV ) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc complete as per specification & the direction of Engineer-in-Charge.Initial test (Test Load 2.5 times the Safe capacity)

-

-

-

... More
Initial test (Test Load 2.5 times the Safe capacity)

-

-

-

... More
Initial test for Single pile of 600mm dia and safe capacity 220Tonne

2

-

-

... More
Initial test for Single pile of 750mm dia and safe capacity 270Tonne

1

-

-

... More
Arranging and conducting vertical load testing of piles in accordance with IS.2911 (Part IV ) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc complete as per specification & the direction of Engineer-in-Charge. Routine test (Test Load 1.5 times the Safe capacity)

-

-

-

... More
Routine test (Test Load 1.5 times the Safe capacity)

-

-

-

... More
Routine test for Single pile of 600mm dia and safe capacity 220Tonne

1

-

-

... More
Routine test for Single pile of 750mm dia and safe capacity 270Tonne

1

-

-

... More
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-40 of specified diameter and length below the pile cap, to carry a safe working load not less than specified,excluding the cost of steel reinforcement but including the cost of concrete, boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine,including all required platform for piling work all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap)and Low strain pile integrity test on all the working piles as per procedure of IS : 2911 (Part 4).Contractor shall include the method of construction with platform in specified location in the method statement.The subject item shall be executed inside the cofferdam area; for slipway piles from Grid 51 to Grid 60, piled platform area piles

-

-

-

... More
1200mm dia piles

1856

-

-

... More
600mm dia pile

1527

-

-

... More
750mm dia pile

703

-

-

... More
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-40 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of concrete, boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap) and Low strain pile integrity test on all the working piles as per procedure of IS : 2911 (Part 4). Note:Truck Mounted rotary/TMR/Tube well boring machine shall not be used.

-

-

-

... More
1200mm dia piles

5271

-

-

... More
1000mm dia piles

4175

-

-

... More
600mm dia pile

15349

-

-

... More
900mm dia piles

7377

-

-

... More
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-40 of specified diameter upto pile cutoff including additional length to chip off for good concrete as per IS 2911, excluding the cost of steel reinforcement but including the cost of concrete and boring with bentonite solution/polymer and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including the barge or platform for piling in water area with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap/beam/slab).Low strain pile integrity test on all the working piles as per procedure of IS : 2911 (Part 4) Contractor shall include the method of construction in water area in the method statement.(slipway crane beam piles from Grid 61 to Grid 68( Refer Drg no DP1059CL01 401 SH 1 of 1).

-

-

-

... More
1200 mm Dia Pile (M40) in marine side

1186

-

-

... More
Arranging and conducting vertical load testing of piles in accordance with IS.2911 (Part IV ) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc complete as per specification & the direction of Engineer-in-Charge. Initial test (Test Load 2.5 times the Safe capacity)

-

-

-

... More
Initial test (Test Load 2.5 times the Safe capacity)

-

-

-

... More
Initial test for Single pile of 1200mm dia and safe capacity 720Tonne

2

-

-

... More
Initial test for Single pile of 1000mm dia and safe capacity 475Tonne

1

-

-

... More
Initial test for Single pile of 900mm dia and safe capacity 380Tonne

1

-

-

... More
Arranging and conducting vertical load testing of piles in accordance with IS.2911(Part IV ) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc complete as per specification & the direction of Engineer-in-Charge. Routine test (Test Load 1.5 times the Safe capacity)

-

-

-

... More
Routine test (Test Load 1.5 times the Safe capacity)

-

-

-

... More
Routine test for Single pile of 1200mm dia and safe capacity 720Tonne

5

-

-

... More
Routine test for Single pile of 1000mm dia and safe capacity 475Tonne

1

-

-

... More
Routine test for Single pile of 900mm dia and safe capacity 380Tonne

4

-

-

... More
Design, erection and dismantling of cofferdam Design, erection and dismantling of temporary twin wall cofferdam preferably using hot rolled steel sheet piles with necessary tie rods, wailing channels, other supporting structures etc as per the approved design and as detailed in the Nature of works, scope of works, procedure of works, material specifications, methodology & drawings etc including cost and conveyance of all labour, equipment, granular/sandbag filling between the twin walls, dewatering, making the area dry. The work involves also designing, vetting of the design, and submission of the approved design notes, calculations and drawings for the temporary cofferdam to HSL. The design and drawings have to be vetted, stamped, signed and dated by a Professor of CivilEngineering/Offshore Engineering Department of any IIT/ NIT. The designs shallbe in accordance with Indian standards. Depth of water at cofferdam constrcution area is 10m and approximate depth of embedment (including rock layer) of the sheet pile is 15 to 20m from seabed. The work includes mobilization and demobilization of all equipment’s, barges, cranes, all materials including cofferdam walls, granular/earth filling etc complete, and labour required for the Work; After dismantling of the cofferdam (-)9.0m CD water depth shall be maintained in the water area

135

-

-

... More
Filling with contractor's own earth ( excluding rock) in open areas including area behind the Cofferdam upto pile cutoff, in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, for all lead and lift including cost and conveyance of all materials,labour charges,lead,lift etc complete at all levels and make good the area to the original position as per the direction of Engineer-in-charge.(Note:After completing the work the excess earth shall be removed from the area without any additional cost)

2640

-

-

... More
(SH: - 2.0 - CONCRETE WORK)

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :

-

-

-

... More
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

2398

-

-

... More
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)

30

-

-

... More
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).

105

-

-

... More
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil

105

-

-

... More
Providing and laying in position cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) up to floor five level excluding the cost of centering, shuttering, finishing for leveling coarse of floor and roof etc.

15

-

-

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.

109

-

-

... More
(SH: - 3.0 - R.C.C. WORK)

-

-

-

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources,Portland Cement (OPC-43 Grade), admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account) .

-

-

-

... More
All works upto plinth level

911

-

-

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources,Portland Cement (OPC-43 Grade) admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works upto plinth level Concrete of M30 grade with minimum cement content of 350 kg /cum (Note :- Minimum Cement content considered in this item is @ 350 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account)

113

-

-

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Cement (OPC-43 Grade), admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works above plinth level upto floor V level. Concrete of M30 grade with minimum cement content of 350 kg /cum (Note :- Minimum Cement content considered in this item is @ 350 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account) .

95

-

-

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources,Prtland Cement (OPC-43 Grade), admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works upto plinth level (All slipway slab and other work upto HPL shall be measured in this item) Concrete of M40 grade with minimum cement content of 390 kg /cum (Note :- Minimum Cement content considered in this item is @ 390 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account. ).

18746

-

-

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources,Portland Cement (OPC-43 Grade), admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works above plinth level upto floor V level. Concrete of M40 grade with minimum cement content of 390 kg /cum (Note :- Minimum Cement content considered in this item is @ 390 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account) .

1970

-

-

... More
Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with M30 grade concrete

129

-

-

... More
Providing Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding with 16 gauge GI binding wire etc complete including cost, conveyance, lead, lift of all materials for all types of RCC works as per drawing/specification and as directed by Engineer-in-Charge.

-

-

-

... More
Upto plinth level.(All slipway slab and other work upto HPL shall be measured in this item) Thermo-Mechanically Treated bars of grade Fe-500D or more.

7766801

-

-

... More
Above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

460020

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for

-

-

-

... More
Foundations, footings, bases of columns etc. for mass concrete.

10281

-

-

... More
Suspended floors, roofs, landings, balconies and access platform.

2753

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers.

1302

-

-

... More
Columns, Pillars, Piers, Abutments, Posts and Struts.

8879

-

-

... More
Stairs, (excluding landings) except spiral staircases.

92

-

-

... More
Edges of slab and breaks in floors and walls under 20 cms wide.

226

-

-

... More
Edges of slab and breaks in floors and walls above 20 cms wide.

75

-

-

... More
Weather shade, Chajjas, corbels etc., including edges.

136

-

-

... More
Walls of (any thickness) including attached pilasters butteresses plinth and string course etc.

9955

-

-

... More
Extra for additional height in centering, shuttering using Plywood/steel/wood where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).

-

-

-

... More
Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

4240

-

-

... More
Supplying, Drilling/Cleaning hole and fixing approved make medium duty ETA Approved toque controlled expansion mechanical anchor GI bolt of appropriate size in concrete and fixing plates subsequently. Anchor should be pre-assembled with a GI stud, expansion sleeve, a nut and a washer. Top end of stud has threads and bottom end has cold formed conical head. Manufacture should submit Anchor Design Report based on Design Loads & other parameters as provided by consultant. Metal anchors should be designed in B125accordance with ETAG 001 Annex C “guidelines for anchorage of metal anchors for use in concrete”. Application at site should be done as per manufacturer guidelines.The rate including the cost and conveyance of all materials, labour charges, lead, lift, etc. complete as directed by Engineer-in- Charge at all levels

-

-

-

... More
For 8mm dia 40mm depth

200

-

-

... More
For 10mm dia 50mm depth

150

-

-

... More
For 12mm dia 60mm depth

100

-

-

... More
For 16mm dia 70mm depth

100

-

-

... More
Supplying, Drilling/Cleaning hole and injecting approved chemical with the help of manual dispenser, into a hole of dia & depth (below mentioned) as per manufacturer/ structural consultant's specification and fixing rebars of the required diameter subsequently. The chemical should have successful usage in dry areas. The chemical should be suitable for both cracked and non-cracked concrete, fire approval Seismic C1/C2 approval. Fixing methodology to be followed as per manufacturers guidelines. - Steel will be paid under separate subhead. Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval.The rate shall include the cost and conveyance of all materials,labour charges,lead,lift etc complete as directed by the Engineer in charge.

-

-

-

... More
16mm dia rebar at 240mm depth

150

-

-

... More
20mm dia rebar at 300mm depth

200

-

-

... More
Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.)

8038

-

-

... More
Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge.Using grade 'A' sealing compound conforming to IS: 1834.

894

-

-

... More
Providing vacuum dewatering ,levelling, smoothening by mechanical / power troweller and power floater, finishing and sprinkling Nitoflor Hardtop Standard/Sika chadpur or equvalent evenly a shake on a ready mixed non-metallic monolithic floor hardening compound with very hard granulates of mineral origin over RCC floor when the concrete in green and touch dry condition at the rate of 4 to 5.5 Kgs/Sqm shall posses a compressive strength of 50N/mm², Abrasion resistance 0.35 mm at 60 minutes as per ASTM C 779 Mohr's scale hardness 8 as per specification and instructions of the manufacturer including Vacuum dewatering, levelling, smoothening by mechanical / power troweller and power floater,Hardner finishing, curing etc. all complete as directed by the Engineer in charge

5556

-

-

... More
(SH: - 4.0 - MASONRY WORK)

-

-

-

... More
Providing and laying factory made Precast concrete solid blocks of 200 mm thickness of grade M10 from approved manufacturer in foundation and plinth in:CM 1:6 ( 1 cement : 6 coarse sand) etc complete.

55

-

-

... More
Providing and laying factory made Precast concrete solid blocks of 200 mm thickness of grade M10 from approved manufacturer in superstructure above plinth level up to floor V level. Cement mortar 1:6 (1 cement : 6 coarse sand)

182

-

-

... More
Providing and laying half block masonry with factory made Precast concrete solid blocks of 100 mm thickness of grade M10 from approved manufacturer in superstructure above plinth level up to floor V level: Cement mortar 1:6 (1 cement : 6 coarse sand)

100

-

-

... More
Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)

22

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 (1 cement : 6 coarse sand)(from floor 2 level up to floor 5 level)

30

-

-

... More
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry including cost and conveyance of MS bars etc complete as directed by Engineer-in-Charge .

64

-

-

... More
(SH: - 5.0 - JOINERY & PARTITION WORKS)

-

-

-

... More
Providing and fixing of hollow metal fire rated doors as per IS 3614: 2021, for 120min integrity & 30min. insulation. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested as per IS/ISO 3008-1 & IS/ ISO 834-1, from Exova/TBW/CBRI approved lab. Labled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Proper label confirming the type of door and the hourly rating is mandatory. Door frame shall be step rebate grooved profile of size 125 x 75mm made out of 1.20mm (18gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system for taking fire rated EPDM seals

-

-

-

... More
All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff. Door leaf shall be 60mm thick fully flush double skin step design door, insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18gauge) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be 120kg/m3 high density mineral wool insulation material. Intumescent seals 15 x 1.5mm to be provided.

-

-

-

... More
All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided for 6mm clear borosilicate fire rated glass as per manufacturers recommendation with a clipon arrangement. Door and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test.Rate shall include supply and installation of frame, shutter as a complete assembly, including all hardware, smoke seals & glass with tapes ,vision panel etc complete as directed by the Engineer in Charge at all levels . (Note: 5% variation in size shall be absorbed in the rate quoted)

-

-

-

... More
Steel door of size 1.20X2.40 m (Single leaf door with vision panel 200x300 mm )

4

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing and paneling to be paid for separately): Powder coated aluminium (minimum thickness of powder coating 50 micron)

-

-

-

... More
For fixed portion

363

-

-

... More
Shutters with star lock for doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required Powder coated aluminium (minimum thickness of powder coating 50 micron)

312

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including providing and fixing top & bottom fixing arrangement for fixing etc all complete as per direction of Engineer-in-charge

6

-

-

... More
Providing and fixing glazing in aluminium/uPVC door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge .at all levels

-

-

-

... More
With float glass panes of 5.50 mm or nearest thickness

57

-

-

... More
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.

2

-

-

... More
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc.complete.

1

-

-

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :200x10mm

4

-

-

... More
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868)transparent or dyed to required colour and shade with necessary screws etc complete as directed by the Engineer-in -Charge at all levels.

-

-

-

... More
Single rubber stopper

2

-

-

... More
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge. 10 x 80 mm

64

-

-

... More
Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC sliding window with necessary screws etc. complete. including cost and conveyance of all materials,labour charges ,lead,lift etc complete as directed by Engineer- in-Charge.

40

-

-

... More
Providing and fixing windows & ventilators, fabricated from roll formed sections made of Galvanized steel, prepainted(base steel as per IS 513"D" quality, Galvanised as per IS 277 with zinc of 120 grams per sq. mtr) with total coated thickness of 0.60 mm. Coated sections should be painted with primer coat of Epoxy primer of 5-7 microns thick, finish painted with pollyster paint of 12-16 microns thick and back coated woth alkyd backer of 5-7 microns thick or powder coated with pure polyester powder coated up to 50-60 microns thick.Section for Shutter should be of 46mm x 46mm and External Frame should be of 46mm x 52mm. Section for Glass Beading should be of 18mm x 25mm and center mullion should be of 46mm x 70mm and 50mm x 50mm box sections for Louvered Ventilators. The Frame & Shutter Sections should be cut to length and mitre joined with Corner Bracket made of CRCA electroplated. Mullion Section should be joined with Frame/ Mullion using Nylon Mullion Cap, box sections for Ventilators should be joined with aluminium ‘L’ brackets and PVC glass holders will be used for Louvered Ventilators. Ethyl Propylene Diamine Monomer (EPDM) Gasket should be used all around glass in shutter, between frame and glazed shutter and both sides of fixed glass.Handle made of high grade Aluminium powder coated and with nylon receiver. Gaskets made of Ethyl Propylene Diamine Monomer (EPDM). Corner brackets made of CRCA with zinc phosphating. Mullion caps made of Glass filled nylon.The assembled outer frame should be fixed sto brick/concrete masonry using nylon self-expanding caps driving MS elecroplated 80 mm long screws in to the caps through outer frames. Glazed shutters are connected to outer frames using GI powder coated friction hinges of 250mm long. The infill for shutter can be 4mm float glass of saint gobain/mosy make complete.

25

-

-

... More
(SH: - 6.0 - STEEL WORK )

-

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position all complete. as directed by Engineer- in-Charge at all levels.

298

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position using structural steel etc. as required.

-

-

-

... More
In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete

3591

-

-

... More
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

7097

-

-

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes

17177

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation where rolling shutter area up to 10sqm and area exceeding 10 sqm mechanical device chain and crank operation etc complete, including the cost of providing and fixing necessary long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover

45

-

-

... More
Providing and fixing ball bearing for rolling shutters including cost and conveyance of all materials, labour, etc. as directed by the Engineer-in-Charge at all levels.

15

-

-

... More
Extra for providing grill rolling shutter manufactured out of 8 mm dia M.S bars instead of laths as per the design approved by the Engineer-in-Charge(area of grill to be measured)

11

-

-

... More
Providing and fixing M.S round holding down bolts with nuts and washer plate including cost and conveyance of all materials, labour charges,lead,lift etc complete as directed by Engineer-in-Charge

362

-

-

... More
Providing and fixing GI pipe hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying synthetic enamel paint with two coats over priming coat of approved steel primer.

240

-

-

... More
Structural steel work riveted, bolted or welded in built up sections for steel liner works , including cutting, hoisting, fixing in position including driving of the steel liner to required depth all complete. as directed by Engineer- in-Charge at all levels.

195762

-

-

... More
Providing ,fixing and welding A120 rails with crane rail system; shall be of the continuously supported type and shall include rail, reinforced neoprene layer, support plate, rail clamps, anchor bolts, grouting and the like and shall be designed for full crane operational and standby loading. All the rail fixtures shall be of GANTREX/GANTRAI. Measurement and payment shall be per meter and the rates shall include the complete supply, installation, welding etc. of rail, reinforced neoprene layer, support plate, rail clamps, anchor bolts, grouting, complete in every respect including cost and conveyance of all materials,labour charges,lead,lift etc complete as directed by the Engineer in charge.

626

-

-

... More
(SH: - 7.0 - FLOORING WORK)

-

-

-

... More
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm

567

-

-

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm

17

-

-

... More
52 mm thick cement concrete flooring with concrete hardener topping under layer 40mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12mm thick Hardcrete cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume hardening compound of approved make is mixed as per manufactures specification and providing and fixing 4 mm thick glass strips in approved pattern including cost of cement slurry, including the cost of nosing of steps etc. complete as directed by the Engineer-in-Charge at all levels.

356

-

-

... More
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. etc. complete as directed by the Engineer-in-Charge at all levels. 18 mm thick

65

-

-

... More
Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge

4060

-

-

... More
(SH: - 8.0 - ROOFING AND CLADDING WORKS)

-

-

-

... More
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer In- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

186

-

-

... More
Providing and fixing precoated galvanised steel sheet Ridges plain (500 - 600mm) 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)

16

-

-

... More
Providing and fixing precoated galvanised steel sheet Gutter 600mm over all girth) 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :

31

-

-

... More
(SH: - 9.0 - FINISHING WORK)

-

-

-

... More
6 mm cement plaster to ceiling of mix 1:3 (1 Cement : 3 fine sand) including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer-in-Charge at all levels.

522

-

-

... More
12mm cement plaster of mix 1:4 (1 cement : 4 fine sand)including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer-in-Charge at all levels.

1569

-

-

... More
15mm cement plaster of mix 1:4 (1 cement : 4 fine sand)including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer-in-Charge at all levels.

1569

-

-

... More
15mm cement plaster of mix, 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement 2 kg/sqm including mixing water proofing material in separately).proportion recommended by manufacturer over roof at all heights including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer-in-Charge at all levels.

4143

-

-

... More
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.

273

-

-

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on all surface including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer-in-Charge at all levels.

2580

-

-

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade for new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) , including cost and conveyance of all materials, labour charges, scaffoldings etc complete as directed by the Engineer-in-Charge at all levels.

1082

-

-

... More
Painting the inside walls with acrylic emulsion paint of approved brand and manufacture to give an even shade two or more coats on new work over to smooth even finish on ceiling and walls including cost and conveyance of all materials to site, labour charges, hire charges for scaffolding, etc as directed by Engineer-in-Charge at all levels

2456

-

-

... More
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.

284

-

-

... More
Providing and applying anticorrosive protective coating on external steel structures – A high performance passivation enhanced epoxy primer having Minimum of volume solids 75% and DFT (Dry Film Thickness) of 75 microns followed by a two component epoxy High Build intermediate MIO, having 80% volume solids and DFT of 150 microns and thereafter top coated with a two component high solids acrylic Polyurethane having Min 50 % volume solids and DFT of 60 microns. Total thickness of minimum 285 Microns or as per manufacturer recommendation. All steel surfaces shall be abrasive blast cleaned to Sa 2.5 (ISO8501-1:1988) or SSPC- SP10 with suitable abrasive Grid/shot. If oxidation has occurred between blasting and paint application, the surface should re-blasted to the specified visual standard. Any surface defects revealed by the blast cleaning process should be filled/ ground or treated suitably. Before blasting, surfaces shall be washed and cleaned by water jet/ Solvent to remove surface contamination/ grease etc.. The rate Including cost and conveyance of all materials , labour charges, lead, lift etc at all heights complete as directed by Engineer in charge.

524

-

-

... More
(SH: - 10.0 - MISCELLANEOUS BUILDING WORK)

-

-

-

... More
Providing and applying Antitermite treatment by injecting chemical emulsion Imidacloprid emulsiable concentrate 0.075% for pre-constructional treatment and creating a chemical barrier as per IS 6313 (Part II) 2001 for wall trenches, foundation, top surface of plinth filling, foundation of wall and floor, along the external perimeter of the building, etc. complete conforming to manufacturers specification and as directed by the Engineer-in-Charge. (Plinth area only to be measured for the payment & guarantee for 10 years shall be given for the work )

833.5

-

-

... More
Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage.

1863

-

-

... More
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete .450 mm dia RCC pipes

53

-

-

... More
(SH: - 11.0 - DISMANTLING WORKS)

-

-

-

... More
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. incluing dismembering and stacking within 50 metres lead.

127300

-

-

... More
Demolishing R.C.C work using breakers or cutting machine or other machinery suitable as per site condition, including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge

10726

-

-

... More
Dismantling existing RCC pile in slipway area using diamond cutting using diamond cutting machines with the assitance of blades/ wires as suitable using all tools and tackles complete. size of the pieces to be approx 2-5mt each. Cutting charges are mentioned for cuts done above water level and cuts will be done at every 2m approx.The rate shall include the cost of cutting including stacking the pieces etc complete as per direction of Engineer-in-Charge

130

-

-

... More
Site clearing charges for lifting, and disposing the cut elements of pile from site for dumping out of site at an area unobjectionable to local authorties. The size of the pieces to be approx 2-5mt each.All work shall be done as per the direction of Engineer in charge.

432

-

-

... More
(SH: - 12.0 - ROAD ,PARKING,RETAINING WALL WORKS)

-

-

-

... More
Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete- 450 mm dia

60

-

-

... More
PART-A-HT_EQUIPMENTS 11kV VCB Panel (For Slipway) Supply, Installation Testing and Commissioning of 11 kV,1250A 25kA( for 3seconds), Electrically operated draw out type VCB with fully encapsulated vacuum interrupter panel with busbar extendable on both side ,fabricated out of 14 gauge CRCA/ Alu zinc sheet. The panel shall be with sufficient capacity power pack required for the necessary DC / auxiliary control & power supply. The panel shall be arc flash tested with 1250A copper busbar & support insulators, space heater with thermostat, cubicle illumination lamp, MCBs for AC/DC Control, motor operated spring charged mechanism, anti-pumping device, shunt trip and closing coil, necessary control wiring etc having following specific components and as per IS / IEC standards. Incomer - 1 No. i)11kV VCB, 1250 A, 25kA, 3 sec. for receiving 11kV supply - 1 No ii) 11kV/√3 / 110V/√3, 50VA, Cl 0.2 PT - 3 No. iii) Core 1 - 300/5A Cl 0.2S 15VA resin cast CT for Metering - 3Nos, iv) Core II - 300/5A Cl 5P10 15VA resin cast CT for Protection - 3 Nos, v) RYB, TRIP, SPRING CHARGED & ON/OFF LED indication lamps, vi) 4A C curve control MCB & 11kV PT HRC Fuse vii) Numerical relay for protection with IEC 61850 compatibility. viii) Digital Power Analyzer with communication facility, viiii) Analog meters Incomer & Bus coupler Future Provision Space - 1 No. Earthing Truck for cable side suitable for all VCBs-1no 11kV VCB Outgoing Panel with 1 no. VCB- 3 nos i)11kV VCB, 1250 A, 25kA, 3 sec as outgoing - 1 No, ii) Core I - 200/5A Cl 0.5 15VA resin cast CT for Metering - 3 Nos, iii) Core II - 200/5A Cl 5P10 15VA resin cast CT for Protection - 3 Nos iv) RYB, TRIP, SPRING CHARGED & ON/OFF LED indication lamps. v) Numerical relay for protection with IEC 61850 compatibility. vi) Digital Power Analyzer vii) Analog meters Vacuum circuit breaker panels shall conform to IEC 62271. The control voltage should be available for trip, closing and compatible for SCADA system complete .Each VCB panel should have panel lighting (LED light fixture) and panel heater with temperature control thermostat.

-

-

-

... More
Supply

1

-

-

... More
Installation, Testing & Commissioning

1

-

-

... More
Addition of HT VCB in SS4 HT panel Supply, Installation, testing and Commissioning of 11 kV,1250A 25kA( for 3seconds), Electrically operated draw out type VCB with fully encapsulated vacuum interrupter panel with busbar ,fabricated out of 14 gauge CRCA/ Alu zinc sheet .The panel shall be arc flash tested with 1250A copper busbar & support insulators, space heater with thermostat, cubicle illumination lamp, MCBs for AC/DC Control, 24V DC motor operated spring charged mechanism, anti-pumping device, 24V DC shunt trip and closing coil, necessary control wiring etc having following specific components and as per IS / IEC standards. i)11kV VCB, 1250 A, 25kA, 3 sec. for receiving 11kV supply - 1 No ii) 11kV/√3 / 110V/√3, 50VA, Cl 0.5 PT - 3 No. iii) Core 1 - 200/5A Cl 0.5 15VA resin cast CT for Metering - 3Nos, iv) Core II - 200/5A Cl 5P10 15VA resin cast CT for Protection - 3 Nos, v) RYB, TRIP, SPRING CHARGED & ON/OFF LED indication lamps, vi) 4A C curve control MCB & 11kV PT HRC Fuse vii) Numerical relay for protection with IEC 61850 compatibility. viii) Digital Power Analyzer with communication facility, viiii) Analog meters Vacuum circuit breaker panels shall conform to IEC 62271. The control voltage should be 24 V DC for trip, closing and compatible for SCADA system complete .Each VCB panel should have panel lighting (LED light fixture) and panel heater with temperature control thermostat.

-

-

-

... More
Supply

1

-

-

... More
Installation, Testing & Commissioning

1

-

-

... More
Supply installation testing and comissioning of 1250 kVA, Dyn 11, 3 Ph, 50Hz, 11 / 0.433 kV, ONAN cooled, copper double wound Indoor distribution transformer with tappings from +5% to -15% in steps of 2.5% with ON load Tap changer, RTCC panel with SCADA compatibility, Cable end box on HT & Provision for Busduct on LT side shall be provided and complete with all fittings and accessories . The transformer shall also have suitable enclosure including supply and fixing of 1no neutral CT of 400/5A 15VA 5P10 and 1no. neutral CT of 2000/5A Class PS on earthed star neutral point with connector for connection to HT/LT panel. The transformer losses shall be as per IS 1180 Star-2 rating ammended up to date. The Item shall includes all necessary control cabling for alarm, tripping & indication, all internal cabling, all materials, lead, lift etc. as required complete as per single line diagram & technical specification.

-

-

-

... More
Supply

1

-

-

... More
Installation, Testing & Commissioning

1

-

-

... More
PART B - LT PANELS : Shore Auxiliary Panel

-

-

-

... More
Supply , Installation, Testing & Commissioning of LT Switch board cubicle type compartmentalised (form 4), made out of 2mm thick CRCA sheet, totally enclosed, IP55,double door, free standing, pedestal mounting, dust and vermin proof, powder coated, outdoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides, including all the necessay internal wiring , with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. Incomer 400A, FP MCCB thermal based release for OL & SC protection (Ics = 100% Icu = 36kA) -1 No Instruments 4A C curve SP MCB, Ammeters, Voltmeters, Selector Switches,Multifunction Meters, Power analyser meter, Indication Lamps, CTs, Protection Relays, interlocks,etc as per SLD . Busbar TPN busbar chamber with Aluminium busbar suitable for 400 A Surge Protection Devices Pluggable type surge arrester Type 2 as per IEC 61643 (IP 20) with inbuilt indication -1 set Out goings 400A, TP + NL MCCB thermal based release for OL & SC protection (Ics = 100% Icu = 36kA) and neutral link-2 Nos ON-OFF -TRIP indication lamp - As per SLD The panel shall be with top/bottom entry to receive incoming & outgoing cable all necessary interconnection & accessories as per particular specification & single line diagram.

-

-

-

... More
Supply

1

-

-

... More
Installation, Testing & Commissioning

1

-

-

... More
MSB (SS-6) Supply , Installation, Testing & Commissioning of LT Switch board cubicle type compartmentalised (form 4), made out of 2mm thick CRCA sheet, totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides, including all the necessay internal wiring , with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. Incomer 2000A, Four pole, 50kA, Electrical Draw Out type ACB with Microprocessor based adjustable over current and earth fault release, RS 485 communication facility- 1 Nos. Instruments 4A C curve SP MCB, Ammeters, Voltmeters, Selector Switches,Multifunction Meters, Power analyser meter, Indication Lamps, CTs, Protection Relays, interlocks,etc as per SLD . Busbar TPN busbar chamber with Copper busbar suitable for 2000 A Surge Protection Devices Pluggable type surge arrester Type 1 as per IEC 61643 (IP 20) with inbuilt indication -1 set Out goings 1000A, Four pole, 50 KA, Electrical Draw Out type ACB with microprocessor based adjustable over current and earth fault release , RS 485 communication facility, - 1No 630A, TP + NL MCCB microprocessor based release for OL & SC protection (Ics = 100% Icu = 50kA) and neutral link 8 Nos 400A, TP + NL MCCB microprocessor based release for OL & SC protection (Ics = 100% Icu = 50kA) and neutral link-1 Nos 250A, TP + NL MCCB microprocessor based release for OL & SC protection (Ics = 100% Icu = 50kA) and neutral link-2 Nos 100A, TP + NL MCCB microprocessor based release for OL & SC protection (Ics = 100% Icu = 50kA) and neutral link-1 Nos ON-OFF -TRIP indication lamp - As per SLD The panel shall be with top/bottom entry to receive incoming & outgoing cable all necessary interconnection & accessories as per particular specification & single line diagram.

-

-

-

... More
Supply

1

-

-

... More
Installation, Testing & Commissioning

1

-

-

... More
Slipway Lighting Panel Supply , Installation, Testing & Commissioning of LT Switch board cubicle type compartmentalised (form 4), made out of 2mm thick CRCA sheet, totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides, including all the necessay internal wiring , with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. Incomer 250A, FP MCCB thermal based release for OL & SC protection (Ics = 100% Icu = 36kA) -1 No Instruments 4A C curve SP MCB, Ammeters, Voltmeters, Selector Switches,Multifunction Meters, Power analyser meter, Indication Lamps, CTs, Protection Relays, interlocks,etc as per SLD . Busbar TPN busbar chamber with Aluminium busbar suitable for 250 A Surge Protection Devices Pluggable type surge arrester Type 2 as per IEC 61643 (IP 20) with inbuilt indication -1 set Out goings 125A, TP + NL MCCB thermal based release for OL & SC protection (Ics = 100% Icu = 36kA) and neutral link-3 Nos 100A, TP + NL MCCB thermal based release for OL & SC protection (Ics = 100% Icu = 36kA) and neutral link-2 Nos ON-OFF -TRIP indication lamp - As per SLD The panel shall be with top/bottom entry to receive incoming & outgoing cable all necessary interconnection & accessories as per particular specification & single line diagram.

-

-

-

... More
Supply

1

-

-

... More
Installation, Testing & Commissioning

1

-

-

... More
SLIPWAY MAIN PANEL(OUTDOOR TYPE) Supply, Installation, Testing & Commissioning of totally enclosed free standing pedestal mounting dust & vermin proof outdoor cubicle type , powder coated ,Form 4, IP55, double door panel board with canopy suitable for 415V, 3 phase, 50Hz supply with provision for fixing incoming & outgoing switches fabricated out of 2mm sheet steel for frame and 1.5mm for door and internal partitions(except load bearing members)with necessary cable alley & bus bar chamber for all switches. The panel shall be with all accessories as per drawing & specification. Refer technical specification and drawing for details. Incomer 630A, FP MCCB Microprocessor based release for OL & SC protection (Ics = 100% Icu = 36kA) -2 No Busbar 630A TPN busbar chamber with Aluminium busbar Instruments 4A, C curve SP MCB, RYB indication lamp, LED type, (0 to 500 )V Voltmeter for 3 phase, 4 wire operation with selector switch, (0-630)A ammeter as per SLD , 630/5A 15VA class 1 resin cast CT, Digital Multi Function Meters as per Single Line Diagram Bus-Coupler 630A, FP MCCB thermal based release for OL & SC protection (Ics = 100% Icu = 36kA) -1 No Surge Protection Devices Pluggable type surge arrester Type 1 as per IEC 61643 (IP 20) with inbuilt indication -1 set Outgoings 250A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 36KA) -1 2 nos Bus bar shall be extendable type. The panel shall be with Top/bottom entry to receive incoming & outgoing cable/busduct, all necessary interconnection & accessories as per technical specification & single line diagram.

-

-

-

... More
Supply

3

-

-

... More
Installation, Testing & Commissioning

3

-

-

... More
SLIPWAY PORTABLE WELDING PANEL (OUTDOOR - PORTABLE PANEL ) Supply of totally enclosed free standing pedestal mounting dust & vermin proof outdoor cubicle type , powder coated ,Form 4, IP55, double door panel board with canopy suitable for 415V, 3 phase, 50Hz supply with provision for fixing incoming & outgoing switches fabricated out of 2mm sheet steel for frame and 1.5mm for door and internal partitions(except load bearing members)with necessary cable alley & bus bar chamber for all switches. The panel shall be with all 30m long multistranded copper flexible cable for tapping power from the nearby welding panel, all accessories as per drawing & specification. Refer technical specification and drawing for details. Incomer 125A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA) - 1 no Busbar 125A TPN busbar chamber with Aluminium busbar Instruments 4A, C curve SP MCB, RYB indication lamp, LED type, (0 to 500 )V Voltmeter for 3 phase, 4 wire operation with selector switch, (0-125)A ammeter as per SLD, 125/5A 15VA class 1 resin cast CT as per Single Line Diagram Surge Protection Devices Pluggable type surge arrester Type 1 as per IEC 61643 (IP 20) with inbuilt indication -1 set Outgoings 63A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA)- 1 no 63A FP MCB and 63A FP 100mA RCCB with 63A 5 pole plug socket - 1no 16A SP MCB and16A DP 100mA RCCB with 16A 3 pole plug socket - 3nos 25A TP MCB and 415V/24V 1500VA transformer with 4 nos of 10A SP MCB and 10A 24V plug socket as per single line diagram The panel shall be of thermoplastic enclosure type & with both male and female plug sockets for the ratings specified. All plug sockets shall be thermoplastic type.

-

-

-

... More
Bus bar shall be extendable type. The panel shall be with Top/bottom entry to receive incoming & outgoing cable/busduct, all necessary interconnection & accessories as per technical specification & single line diagram.

30

-

-

... More
SLIPWAY WELDING PANEL (OUTDOOR) Supply, Installation, Testing & Commissioning of totally enclosed free standing pedestal mounting dust & vermin proof outdoor cubicle type , powder coated ,Form 4, IP55, double door panel board with canopy suitable for 415V, 3 phase, 50Hz supply with provision for fixing incoming & outgoing switches fabricated out of 2mm sheet steel for frame and 1.5mm for door and internal partitions(except load bearing members)with necessary cable alley & bus bar chamber for all switches. The panel shall be with all accessories as per drawing & specification. Refer technical specification and drawing for details. Incomer 250A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA) - 1 no Busbar 250A TPN busbar chamber with Aluminium busbar Instruments 4A, C curve SP MCB, RYB indication lamp, LED type, (0 to 500 )V Voltmeter for 3 phase, 4 wire operation with selector switch, (0-250)A ammeter as per SLD,250/5A 15VA class 1 resin cast CT as per Single Line Diagram Surge Protection Devices Pluggable type surge arrester Type 1 as per IEC 61643 (IP 20) with inbuilt indication -1 set Outgoings 125A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA)- 1 no 2 nos of 32A FP MCB with 63A FP 100mA RCCB and 2 nos of 32A 5 pole plug socket as per single line diagram - 1 set 63A FP MCB and 63A FP 100mA RCCB with 63A 5 pole plug socket - 3nos 32A SP MCB and 32A DP 100mA RCCB with 32A 3 pole plug socket - 2nos 16A SP MCB and16A DP 100mA RCCB with 16A 3 pole plug socket - 2nos The panel shall be with both male and female plug sockets for the ratings specified. All plug sockets shall be thermoplastic type. Bus bar shall be extendable type. The panel shall be with Top/bottom entry to receive incoming & outgoing cable/busduct, all necessary interconnection & accessories as per technical specification & single line diagram.

-

-

-

... More
Supply

30

-

-

... More
Installation, Testing & Commissioning

30

-

-

... More
Fire Panel 1 Supply, Installation, Testing & Commissioning of totally enclosed free standing pedestal mounting dust & vermin proof indoor cubicle type , powder coated , IP42 panel board suitable for 415V, 3 phase, 50Hz supply with provision for fixing incoming & outgoing switches fabricated out of 2mm sheet steel for frame and 1.5mm for door and internal partitions(except load bearing members)with necessary cable alley & bus bar chamber for all switches. The panel shall be with all accessories as per drawing & specification. Refer technical specification and drawing for details. Incomer 400A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 36KA) - 1 no Busbar 400A TPN busbar chamber with Aluminium busbar Instruments 4A, C curve SP MCB, RYB, ON/OFF indication lamp, LED type, (0 to 500 )V Voltmeter for 3 phase, 4 wire operation with selector switch, (0-400)A ammeter with selector switch as per SLD, 400/5A 15VA class 1 resin cast CT as per Single Line Diagram Surge Protection Devices Pluggable type surge arrester Type 1 as per IEC 61643 (IP 20) with inbuilt indication -1 set Outgoings 400A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 36KA) - 1 No. 320A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 36KA) - 1 No. On/Off indication lamp, LED type for out goings - 2 No. 3 phase Star delta starter with on/off push button,thermal overload relay, single phasing preventer and auxillary & power contactors for 125KW pump - 1 No. 100A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA) - 2 Nos. On/Off indication lamp, LED type for out goings - 2 Nos. 3 phase Star delta starter with on/off push button,thermal overload relay, single phasing preventer and auxillary &power contactors for 7.5Kw pumps - 2 Nos. 25 A DP MCB - 2 Nos. Bus bar shall be extendable type. The panel shall be with Top/bottom entry to receive incoming & outgoing cable/busduct, all necessary interconnection & accessories as per technical specification & single line diagram.

-

-

-

... More
Supply

1

-

-

... More
Installation, Testing & Commissioning

1

-

-

... More
APFC PANEL (400kVAR) Supply, Installation, Testing & Commissioning of totally enclosed free standing floor mounting dust & vermin proof indoor cubicle type, powder coated ,Form 3b, IP42, thyristor based capacitor panel board suitable for 415V, 3 phase, 50Hz supply with provision for fixing incoming & outgoing switches fabricated out of 2mm sheet steel for frame and 1.5mm for door and internal partitions(except load bearing members)with necessary cable alley & bus bar chamber for all switches. The panel shall be with all accessories as per drawing & specification. Refer technical specification and drawing for details. The panel shall be of OEM make. Control cable from MSB to APFC panel included Incomer 1000A, Four pole, 50 KA, Electrical Draw Out type ACB with microprocessor based adjustable over current and earth fault release , RS 485 communication facility, - 1Nos. Instruments 4A, C curve SP MCB , RYB, ON,OFF,TRIP indication lamp, LED type, - 1 no., (0-500)V voltmeter, Acc. class 1 with 90 deg defl. scale , (0-1000)A ammeter Acc. class 1 with 90 deg defl. scale , Voltmeter selector switch, Ammeter selector switch, 1000/5A 15VA class 1 resin cast CT, Microprocessor based intelligent, 14 step IPFC relay with PF display, Auto / manual selector switch as per Single Line Diagram Busbar 1000A TPN busbar chamber with Aluminium busbar. Surge Protection Devices Pluggable type surge arrester Type 1 as per IEC 61643 (IP 20) with inbuilt indication -1 set Out Going 125A, 25kA, TP MCCB with adjustable thermal magnetic release with OL & SC protection. 8 nos. 63A, 25kA, TP MCCB with adjustable thermal magnetic release with OL & SC protection. 4 nos. 50 kVAr capacitor thyristor based contactor with illuminated ON- OFF pushbuttons (LED type)- 7 Nos. 30 kVAr capacitor thyristor based contactor with illuminated ON- OFF pushbuttons (LED type)- 1 No. 20 kVAr capacitor thyristor based contactor with illuminated ON- OFF pushbuttons (LED type)- 1 No. 50 kVAr,480 V,50 Hz capacitor (APP) with 7 % Seriesreactor - 7 Nos 30 kVAr,480 V,50 Hz capacitor (APP) with 7 % Seriesreactor - 1 Nos 20 kVAr,480 V,50 Hz capacitor (APP) with 7 % Seriesreactor - 1 Nos Bus bar shall be extendable type. The panel shall be with Top/bottom entry to receive incoming & outgoing cable/busduct, all necessary interconnection & accessories as per technical specification & single line diagram.

-

-

-

... More
Supply

1

-

-

... More
Installation, Testing & Commissioning

1

-

-

... More
STEP DOWN LIGHTING TRANSFORMER 433/24V 15KVA

-

-

-

... More
Supply of 15 kVA 433/24 V 3 phase Vector DYN 11 Lighting Transformer with off circuit tappings from +5% to -10% in steps of 2.5%, first fill of oil up to MOL in the conservator, with all the standard fittings and accessories confirming to IS: 2026/77

30

-

-

... More
"PART-C- UPS AND ACCESSORIES Supply , Installation, Testing and Commissioning of 1 kVA, single phase input, single phase output, true on-line UPS system with 15 minutes back up , output isolation transformer, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as cabling etc as required complete having following specification.The UPS system consist of one numbers of UPS unit andone set of battery bank . " Fully digital controlled based on DSP Power factor corrected from end 0.9 Pure sine wave output. Full time output voltage & frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch Auto temperature compensation

-

-

-

... More
Supply

1

-

-

... More
Installation, Testing & Commissioning

1

-

-

... More
PART D- BUSDUCT AND ACCESSORIES Supply, Installation, Testing and Commissioning of Indoor type, IP54 rated, Sandwich TPN with 100% neutral Bus duct, 415V, 50 kA, 50Hz AC supply, suitable for indoor installation of following Ampere capacity made out of Aluminium alloy with powder coating painting, aluminium bus bar , bus bar supports, proper supporting arrangement with metal suspenders/ brackets etc., flexible end termination and complete with fittings & accessories like elbows, offset sections, tees, reducers, adaptor boxes, flanges, flexible connections & expansion joints, ground strips, and earthing with continual integral/internal earth busbar or provision for running 2nos, 25x6mm Cu earth strip along with bus duct etc. as required. (The rate shall be quoted for running meter and the length of elbows, bends, adaptor box, supports also measured under running meter and the rate inclusivce all assosiated accessories and extra claim shall not be entertrained). 2000A TPN Indoor type Sandwich Bus duct

-

-

-

... More
Supply

20

-

-

... More
Installation, Testing & Commissioning

20

-

-

... More
Supply, Installation, Testing and Commissioning of Indoor type, IP54 rated, Sandwich TPN with 100% neutral Bus duct, 415V, 50 kA, 50Hz AC supply, suitable for indoor installation of following Ampere capacity made out of Aluminium alloy with powder coating painting, aluminium bus bar , bus bar supports, proper supporting arrangement with metal suspenders/ brackets etc., flexible end termination and complete with fittings & accessories like elbows, offset sections, tees, reducers, adaptor boxes, flanges, flexible connections & expansion joints, ground strips, and earthing with continual integral/internal earth busbar or provision for running 2nos, 25x6mm Cu earth strip along with bus duct etc. as required. (The rate shall be quoted for running meter and the length of elbows, bends, adaptor box, supports also measured under running meter and the rate inclusivce all assosiated accessories and extra claim shall not be entertrained) - 1000A TPN Indoor type Sandwich Bus duct

-

-

-

... More
Supply

20

-

-

... More
Installation, Testing & Commissioning

20

-

-

... More
PART-E CABLES AND CABLING

-

-

-

... More
Supply of following sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 11 KV grade conforming to IS 7098 amended upto date. 3C X 300sq.mm.

874

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm

480

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed/ XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 120 sq. mm and upto 400 sq. mm

47

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. Above 120 sq. mm and upto 400 sq. mm

20

-

-

... More
Laying of one no. PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in recess/ surface/ cable tray/ wall with saddles, clamps and all other accessories as required Above 120 sq. mm and upto 400 sq. mm

307

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required. Above 120 sq. mm and upto 400 sq. mm

20

-

-

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 3C X300 sq.mm.

21

-

-

... More
Supplying and making straight through cable jointing with cast resin compound, including ferrule and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 3C X300sq.mm.

3

-

-

... More
SUPPLY Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date.

-

-

-

... More
3.5C 400 Sq.mm Al

6877

-

-

... More
3.5C 300 Sq.mm Al

3312

-

-

... More
3.5C 240 Sq.mm Al

259

-

-

... More
3.5C 70 Sq.mm Al

105

-

-

... More
3.5C 50 Sq.mm Cu

3150

-

-

... More
4C 35 Sq.mm Al

315

-

-

... More
4C 16 Sq.mm Al

126

-

-

... More
4C 4 sqmm Cu

42

-

-

... More
2C 4 sqmm Cu

105

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
3.5C 400 Sq.mm Al- Supply

60

-

-

... More
3.5C 400 Sq.mm Al- Installation

60

-

-

... More
3.5C 300 Sq.mm Al- Supply

71

-

-

... More
3.5C 300 Sq.mm Al- Installation

71

-

-

... More
3.5C 240 Sq.mm Al-Supply

5

-

-

... More
3.5C 240 Sq.mm Al-Installation

5

-

-

... More
3.5C 70 Sq.mm Al- Supply

2

-

-

... More
3.5C 70 Sq.mm Al- Installation

2

-

-

... More
3.5C 50 Sq.mm Cu- Supply

60

-

-

... More
3.5C 50 Sq.mm Cu-Installation

60

-

-

... More
4C 35 Sq.mm Al-Supply

8

-

-

... More
4C 35 Sq.mm Al-Installation

8

-

-

... More
4C 16 Sq.mm Al- Supply

12

-

-

... More
4C 16 Sq.mm Al-Installation

12

-

-

... More
4C 4 Sq.mm Cu-Supply

4

-

-

... More
4C 4 Sq.mm Cu-Installation

4

-

-

... More
2C 4 sqmmCu-Supply

4

-

-

... More
2C 4 sqmmCu- Installation

4

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall or surface as required.

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

72

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

1585

-

-

... More
Above 185 sq. mm and upto 500 sq. mm (clamped with 40x3mm MS flat clamp)

1187

-

-

... More
Laying of one number PVC insulated and PVC sheathed armoured power cable of 1.1kV grade fo the following sizes in ground including excavation ,sand cushioning , providing protective covering and refilling the trench etc. as required

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

90

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

20

-

-

... More
Above 185 sq. mm and upto 500 sq. mm (clamped with 40x3mm MS flat clamp)

155

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.

-

-

-

... More
Upto 35 sq. mm

50

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

10

-

-

... More
Above 185 sq. mm and upto 500 sq. mm

555

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
Upto 35 sq mm

35

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

4

-

-

... More
Above 185 sq. mm and upto 500 sq. mm

415

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.

-

-

-

... More
Upto 35 sq mm

35

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

4

-

-

... More
Above 185 sq. mm and upto 500 sq. mm

195

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required.

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

310

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

1632

-

-

... More
Above 185 sq. mm and upto 500 sq. mm (clamped with 40x3mm MS flat clamp)

6942

-

-

... More
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required

-

-

-

... More
50 mm-Supply

50

-

-

... More
50 mm-Installation

50

-

-

... More
100 mm-Supply

150

-

-

... More
100 mm-Installation

150

-

-

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.

-

-

-

... More
100 mm dia-Supply

50

-

-

... More
100 mm dia-Installation

50

-

-

... More
300 mm dia-Supply

50

-

-

... More
300 mm dia-Installation

50

-

-

... More
Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and fixing in cable trench or surface with supports / duly suspended from the ceiling with M8 threaded rod and all necessery accessories as required

-

-

-

... More
900 MM WIDTH X 75 MM DEPTH X 2 MM THICK-Supply

250

-

-

... More
900 MM WIDTH X 75 MM DEPTH X 2 MM THICK-Installation

250

-

-

... More
600 MM WIDTH X 75 MM DEPTH X 2 MM THICK-Supply

4176

-

-

... More
600 MM WIDTH X 75 MM DEPTH X 2 MM THICK-Installation

4176

-

-

... More
450 MM WIDTH X 50 MM DEPTH X 2 MM THICK- Supply

336

-

-

... More
450 MM WIDTH X 50 MM DEPTH X 2 MM THICK-Installation

336

-

-

... More
300 MM WIDTH X 50 MM DEPTH X 2 MM THICK- Supply

864

-

-

... More
300 MM WIDTH X 50 MM DEPTH X 2 MM THICK- Installation

864

-

-

... More
150 MM WIDTH X 50 MM DEPTH X 2 MM THICK- Supply

100

-

-

... More
150 MM WIDTH X 50 MM DEPTH X 2 MM THICK- Installation

100

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, fixing in cable trench or surface with supports / suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
600 MM WIDTH X 50 MM DEPTH X 1.6MM THICK- Supply

50

-

-

... More
600 MM WIDTH X 50 MM DEPTH X 1.6MM THICK- Installation

50

-

-

... More
300 MM WIDTH X 50 MM DEPTH X 1.6MM THICK-Supply

100

-

-

... More
300 MM WIDTH X 50 MM DEPTH X 1.6MM THICK-Installation

100

-

-

... More
150 MM WIDTH X 50 MM DEPTH X 1.6 MM THICK- Supply

150

-

-

... More
150 MM WIDTH X 50 MM DEPTH X 1.6 MM THICK- Installation

150

-

-

... More
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

25

-

-

... More
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

25

-

-

... More
Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required

-

-

-

... More
Supply

600

-

-

... More
Installation

600

-

-

... More
Providing & fixing Fire Barrier mortar with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 and UL 1479 for horizontal openings in fire rated floors or slabs and vertical openings in walls for passing service shafts. The service lines could be of various types like electrical cables trays, metal pipes, GI Ducts for AC, etc.The mortar shall have minimum hardened density of 0.8 g/cm3 and It should have a compressive strength of 2.9N/Sq mm . The product shall be Smoke & Air Seal and 30 years Age tested as per Dafstb and DIBT standards. The product shall be tested and approved by third party agencies such as UL and FM. The mortar should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable.

5

-

-

... More
PART- F- WIRING AND ACCESSORIES Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.GROUP C. (Note:The total distance from the switch box to the point will not exceed 5mtr, incase if length increases above 5 metres, the wiring shall be measured under item 73.01

40

-

-

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.. (Note:The total distance from the switch box to the point will not exceed 5mtr, incase if length increases above 5 metres, the wiring shall be measured under item 73.01

4

-

-

... More
Wiring for group controlled (looped) light point/fan point/ exhaust fan point/ call bell point(without independent switch etc.) with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc as required.(Note:The total distance from one point to another the point will not exceed 5mtr, incase if length increases above 5 metres, the wiring shall be measured under item 73.01)- Group C

20

-

-

... More
Circuit wiring -Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

320

-

-

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

165

-

-

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

850

-

-

... More
2 X 6 sq. mm + 1 X 6 sq. mm earth wire

750

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.

-

-

-

... More
3x1.5sqmm

64

-

-

... More
3x2.5sqmm

33

-

-

... More
3x4sqmm

170

-

-

... More
Supplying and fixing following modular switch/ socket with modular plate & cover on surface or in recess, including proving and fixing suitable size GI box,inter connection etc as required complete.

-

-

-

... More
15/16 amp switch

2

-

-

... More
6 pin 15/16 amp socket outlet

2

-

-

... More
Telephone socket outlet

5

-

-

... More
Bell push

4

-

-

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

4

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

15

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

6

-

-

... More
Supply & fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)

4

-

-

... More
Supply, fixing of Network point, UTP RJ45, CAT 6 modular type socket with modular plate & cover on surface or in recess, including proving and fixing suitable size GI box, inter connection etc as required complete.

4

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

200

-

-

200

-

-

40

-

-

... More
Supply and fixing following size / Module GI box in surface/ recess etc . As required

-

-

-

... More
1 or 2 Module

17

-

-

... More
PART -G- MCBs AND MCB DISTRIBUTION BOARDS Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)

-

-

-

... More
8 way (8 + 24), Double door- Supply

1

-

-

... More
8 way (8 + 24), Double door- Installation

1

-

-

... More
6 way (8 + 18), Double door- Supply

1

-

-

... More
6 way (8 + 18), Double door- Installation

1

-

-

... More
4 way (8 + 12), Double door- Supply

1

-

-

... More
4 way (8 + 12), Double door- Installation

1

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
8 way (8 + 24), Double door- Supply

1

-

-

... More
8 way (8 + 24), Double door- Installation

1

-

-

... More
6 way (8 + 18), Double door- Supply

1

-

-

... More
6 way (8 + 18), Double door- Installation

1

-

-

... More
4 way (8 + 12), Double door- Supply

2

-

-

... More
4 way (8 + 12), Double door- Installation

2

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
12 way, Double door- Supply

2

-

-

... More
12 way, Double door- Installation

2

-

-

... More
Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required

-

-

-

... More
4 pole 40 amps. (415 Volts),30mA sensitivity.-Supply

2

-

-

... More
4 pole 40 amps. (415 Volts),30mA sensitivity.- Installation

2

-

-

... More
4 pole 40 amps. (415 Volts), 100mA sensitivity.- Supply

1

-

-

... More
4 pole 40 amps. (415 Volts), 100mA sensitivity.-Installation

1

-

-

... More
4 pole 25 amps. (415 Volts), 30mA sensitivity-Supply

1

-

-

... More
4 pole 25 amps. (415 Volts), 30mA sensitivity-Installation

1

-

-

... More
2 pole 25 amps. (240 Volts), 30mA sensitivity-Supply

2

-

-

... More
2 pole 25 amps. (240 Volts), 30mA sensitivity-Installation

2

-

-

... More
Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required.

-

-

-

... More
6A to 32A, SP, B/C-CURVE- Supply

66

-

-

... More
6A to 32A, SP, B/C-CURVE- Installation

66

-

-

... More
6 A to 32 A TP MCB, C-CURVE- Supply

2

-

-

... More
6 A to 32 A TP MCB, C-CURVE- Installation

2

-

-

... More
6 A to 32 A SP MCB, D-CURVE- Supply

4

-

-

... More
6 A to 32 A SP MCB, D-CURVE-Installation

4

-

-

... More
40-63A FP MCB, C-CURVE-Supply

1

-

-

... More
40-63A FP MCB, C-CURVE- Installation

1

-

-

... More
40-63A TP MCB, C-CURVE- Supply

2

-

-

... More
40-63A TP MCB, C-CURVE- Installation

2

-

-

... More
Supply, Installation, Testing & Commissioning of 63A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.

-

-

-

... More
Supply

2

-

-

... More
Installation, Testing & Commissioning

2

-

-

... More
Supply, Installation, Testing & Commissioning of 40A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.

-

-

-

... More
Supply

2

-

-

... More
Installation, Testing & Commissioning

2

-

-

... More
Supply, Installation, Testing & Commissioning of 25A DP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.

-

-

-

... More
Supply

5

-

-

... More
Installation, Testing & Commissioning

5

-

-

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

-

-

-

... More
Supply

25

-

-

... More
Installation

25

-

-

... More
Supply and fixing outdoor type START/STOP (2way) push button station (IP65) including all the necessary accessories as required complete with suitable mounting arrangement.(Cat No Hensel-PBS 0201 or equivalent approved make)

-

-

-

... More
Supply

4

-

-

... More
Installation

4

-

-

... More
Supply installation, testing and commissioning of out door (IP 54 ) DOL starter upto 5HP, 3ph motor including auxiliary contactors, SPP relay , illuminated pushbuttons, provision for remote operation all the necessary accessories as required complete. The starter enclosure shall be made of powder coated 1.6 mm CRCA sheet.

-

-

-

... More
Supply

5

-

-

... More
Installation, Testing & Commissioning

5

-

-

... More
Supply installation, testing and commissioning of out door (IP 54 ) Full automatic star delta starter for 15 HP, 3ph motor including auxiliary contactors, illuminated pushbuttons, provision for connecting external pressure switch, and remote operation, etc, all the necessary accessories as required complete. The starter enclosure shall be made of powder coated 1.6 mm CRCA sheet.

-

-

-

... More
Supply

5

-

-

... More
Installation, Testing & Commissioning

5

-

-

... More
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Supply

3

-

-

... More
Installation, Testing & Commissioning

3

-

-

... More
Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Supply

3

-

-

... More
Installation, Testing & Commissioning

3

-

-

... More
Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Supply

3

-

-

... More
Installation, Testing & Commissioning

3

-

-

... More
PART- H-LIGHT FIXTURES AND FANS Supply of indoor industrial surface mounted LED tube with Batten along with driver , surge protector,,system wattage of maximum 40Watts,lumen output of luminaire greater than 4000 lumen, power factor 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 100lumen/watt and including all necessary accessories as required complete.Make:- Cat No: WIPRO OPTIMA ll24

24

-

-

... More
Supply of indoor decorative surface mounted LED Batten with Polycarbonate Diffuser ,along with driver,system wattage of maximum 10 Watts,lumen output of luminaire greater than 1000, power factor 0.9,rated life of L70 @ 25,000 hours, system efficacy greater than 100lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: OSRAM LUXSMART led BATTEN G2 or equivalent approved make

4

-

-

... More
Supply of indoor decorative surface mounted LED Batten with Polycarbonate diffuser, along with driver,system wattage of maximum 18Watts,lumen output of luminaire greater than 2000, power factor 0.9,rated life of L70 @ 25,000 hours, system efficacy greater than 100lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: Osram Luxsmart LED batten G2 or equivalent approved make

8

-

-

... More
Supply of recess mounted LED panel light fixture light made of die cast aluminium with corrosion resistance p[owder coating and with proper diffusers, along with driver,system wattage of maximum 36 Watts with lumen output of fixture not less than 3600 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt and including all necessary accessories as required complete.Make:- PHILIPS LCDN-18-CDL or WIPRO CRCO10R038HP57GL1 or equivalent approved make

4

-

-

... More
Supply of surface mounted LED panel light fixture light made of die cast aluminium with corrosion resistance p[owder coating and with proper diffusers, along with driver,system wattage of maximum 36 Watts with lumen output of fixture not less than 3600 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt and including all necessary accessories as required complete.Make:-or WIPRO CRCO10S038HP57GL1 or equivalent approved make

2

-

-

... More
Supply of LED recess mounted down light made of die cast aluminium, along with driver,system wattage of maximum 18Watts,lumen output of luminaire greater than 1600 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 90umen/watt and including all necessary accessories as required complete.Make:- Cat No: Wipro:Helios 231 LED or equivalent approved makes

4

-

-

... More
Supply of high efficient surface downlighter made of die cast aluminium along with driver,system wattage maximum of 18Watts,lumen output of luminaire greater than 1800 lumens, power factor 0.9,rated life of L70 @ 50,000 hours with suitable driver and including all necessary accessories as required complete.(Make - Wipro LD06-221-XXX-60-SM or equivalent approved make)

2

-

-

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm or sufficient length down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(Rate shall inclusive of supply and installation of remote/electronic regulator)

-

-

-

... More
Supply

4

-

-

... More
Installation, Testing & Commissioning

4

-

-

... More
Supply of 10w LED Bulkhead fitting with die cast aluminium housing, PC diffuser and IP66 Protection suitable for operation on 230V 50Hz AC, wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire and making good the surface as required. (Make:Wipro LW07 or equivalent approved make)

24

-

-

... More
Supply of IP66 LED Floodlight luminaire ,pressure die cast aluminium housing body with optimal heat sink, with system wattage of maximum 60W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 & with system lumens greater than 6000 and system efficiency greater than or equal to 100%.Make:- Cat No: Wipro LF19-711-060-57-G2 or or equivalent approved make

4

-

-

... More
Supply of IP66 LED Street Lighting luminaire ,pressure die cast aluminium housing body with optimal heat sink, with system wattage of maximum 30W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 & with system lumens greater than 3000 and system efficiency greater than or equal to 90%.The Light fitting shall be with all required accessories suitable for mounting on the pole arm.The luminaire should have Inbuilt surge protection of4KV (L-N ,L-E & N-E)and should be equipped with external surge protection device (SPD) to withstand 5KV5AMake:- Cat No: Wipro LR02-331-XXX-57-XX or equivalent approved make.

8

-

-

... More
Supply of LED Highbay fixture with high pressure die cast aluminium housing,system wattage of maximum 200Watts,lumen output of lamp greater than or equal to 22000 lumens, power factor 0.9,rated life of L70 @ 50,000 hours , minimum system efficacy of 110lumen/watts ,with suitable driver and including all necessary accessories as required complete.Make:- Cat No:Wipro-RadialLED LH20-272-060-57-XXor equivalent approved make.

4

-

-

... More
Supply of LED flameproof LED wellglass fixture with high pressure die cast aluminium housing with heat resistant toughened glass,system wattage of maximum 30Watts,lumen output of lamp greater than or equal to 3000 lumens, power factor 0.9,rated life of L70 @ 50,000 hours , minimum system efficacy of 100lumen/watts ,with suitable driver, junction box, glands and including all necessary accessories as required complete.Make:- Cat No:crompton FWL1315-30-CDL or equivalent approved make

20

-

-

... More
Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Make: Orient Smart Air Exhaust or equivalant approved make)

4

-

-

... More
Supply of 450mm sweep heavy duty exhaust fan indie cast aluminium with self opening louvers working on 230 V AC supply complete with all accessories as required. (Make: ALMONARD or equivalant approved make)

2

-

-

... More
Supply of 400 mm size wall fan having speed control, oscillation control at bottom and suitable for operation on single phase 230 volt, 50Hz AC supply complete with continuous duty motor and all accessories as required complete. (Make: Orient Snow Fall or equivalant approved make)

2

-

-

... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

64

-

-

... More
Installation, testing and commissioning of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing & commissioning etc as required.

6

-

-

... More
Installation, testing and commissioning of LED type fittings on wall/Column/truss/false ceiling/slab of height 25m and above using 25mm heavy duty GI conduit of thickness 1.6mm (TATA, Jindal or equivalent) with GI clamps , adequate structural sections, antifall arrangement with 2mm PVC coated GI wire rope,necessay drilling only (without gas cutting) having the holes deburred or rounded using rubber grommets, spacers with 20mm long x ID 12 mm x OD 18mm,cotter pin, Stainless Steel nuts bolts and washers etc for a length of 1mtr including connections with 3C 2.5 Sq.mm PVC insulated flexible copper conductor cable ,ceiling rose etc complete as required.

4

-

-

... More
Providing and fixing extra 25mm heavy duty GI conduit of thickness 1.6mm ( TATA, JIndal or equivalent) for a length of 1mtr and wiring with 3C 2.5 Sq.mm PVC insulated flexible copper conductor cable, 2mm dia wire rope(anti falling) etc complete as required .

12

-

-

... More
Installation, testing and commissioning of High bay/Mid bay/LED/ FLOOD type fittings on wall/Column/truss/false ceiling using suitable MS clamps, nuts, bolts/ 20mm heavy duty GI chain/ pipe (upto 50cm)etc including connections with 3C 2.5 Sq.mm PVC insulated flexible copper conductor cable as required.

32

-

-

... More
Installation, testing and commissioning of LED down lighter fittings on false ceiling with all mounting accessories as required complete including interconnections using 3 core 1.5 sqmm FRLS PVC insulated flexible copper conductor as required.

4

-

-

... More
Installation, testing and commissioning of LED fittings with GI chain /copper wiring - Installation testing and commissioning of prewired LED fittings of all types complete with all accessories, lamps etc. on false ceiling including supplying and fixing of GI chain and hook arrangement, upto 60cm ( between slab and ceiling) , and interconnections using 3 core 1.5 sqmm FRLS PVC insulated flexible copper conductor as required.

4

-

-

... More
Installation, testing and commissioning of wall fan, including wiring with 3 core 1.5 sqmm FRLS PVC insulated flexible copper conductor as required.including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

2

-

-

... More
Numbering of ceiling fan / exhaust fan/ fluorescent fitting as required.

120

-

-

... More
PART -I- EARTHING AND SAFETY EQUIPMENTS Earthing with C.I. earth pipe 3 metre long, 100 mm dia including accessories, and providing masonry enclosure with heavy duty CI cover plate of 300X300mm having locking arrangement and watering pipe etc. with 64kg charcoal/ coke and 5kg salt as required. (As per IS 3043 ammended uptodate)

23

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

-

-

... More
Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required.

-

-

-

... More
75mm X12mm GI

1038

-

-

... More
50mm X10mm GI

2477

-

-

... More
25mm X 6mm GI

865

-

-

... More
25mm X 3 mm Cu

100

-

-

... More
3.15mm Cu (10 SWG)

112

-

-

... More
4mm GI (8 SWG)

100

-

-

... More
Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

-

-

-

... More
75mm X12mm GI

938

-

-

... More
50mm X10mm GI

1350

-

-

... More
25mm X 6mm GI

2600

-

-

... More
25mm X 3 mm Cu

100

-

-

... More
3.15mm Cu (10 SWG)

35

-

-

... More
4mm GI (8 SWG)

250

-

-

... More
Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2 mm for 440V grade thick, +/- 10% confirming to BIS, meeting requirements of IS standards (with upto date amendment), suitable for 440V voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound.

25

-

-

... More
Supply and fixing of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2.5 mm for 11kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 11kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound .

20

-

-

... More
Supply and fixing of First aid box

2

-

-

... More
Supplying of Rubber hand gloves suitable for 11 KV.

2

-

-

... More
Supply and fixing anodised aluminum glass framed shock treatment chart.

2

-

-

... More
Supply and fixing single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required complete on wall.

2

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

5

-

-

... More
Supply and fixing single line diagram, schematic diagrams etc. of A0 size on suitable Aluminium sheet including lamination etc. as required complete on wall.

2

-

-

... More
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

5

-

-

... More
PART- J- EXTERNAL LIGHTING- HIGH MAST Design & Supply of 30m height high Mast lighting system with accessories. Mast shaft shall be in 3 section , hot dip galvanized having top dia minimum 150 mm,bottom dia and plate thickness as per the structural requirement and suitable for wind velocity as per IS 875 part 3.It shall also include accessories for high mast including head frame ,stainless steel wire rope of minimum dia 6 mm , lightning arrestor, 2nos Earthing with C.I. earth pipe 3 metre long, 100 mm dia including connection to High mast earth terminal with 25 X 6 mm GI flats with accessories, and providing masonry enclosure with heavy duty CI cover plate of 300X300mm having locking arrangement and watering pipe etc. with 64kg charcoal/ coke and 5kg salt as required. (As per IS 3043 amended up-to-date) There shall be a control panel housing suitable rating switchgear, separate Contactors & timers for LED luminaire circuit, 24 hrs Digital Timer with inbuilt battery and control circuit at the bottom of the mast with suitable provision for incoming and outgoing cable termination. Flexible copper trailing cable of minimum 8 core 4 sq.mm shall be provided from bottom to top. This cable shall be terminated at a galvanized junction box at the top.From this junction box to the luminaires minimum 3 core 1.5 sq mm flexible PVC cable through flexible conduit shall be used, double drum winch,galvanised Lantern carriage arrangement suitable for required no of 400W LED Luminaire (asymmetrical arrangement) as per design and its drivers ) arranged as per design. High mast shall be provided with single dome aviation obstruction lamps. Minimum galvanizing thickness of 65 microns should be maintained uniform through out the mast . Supply of single gear double drum winch having capacity of minimum 750kg and operating speed of suitable rpm, 2 nos of 6mm 304 Wire rope with safety factor over 5,metal clad socket with cap and hooking arrangement for power tool should be provided inside with each mast, portable power tool having output speed of suitable rpm, torque limiter, operating handle for manual operation etc,Trailing cable having adequate current rating etc as required complete.

3

-

-

... More
Supply of IP66 LED Floodlight luminaire ,pressure die cast aluminium housing body with optimal heat sink, with system wattage of maximum 400W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 & with system lumens greater than 45000 and system efficiency greater than or equal to 100%. ( Make Bajaj MPL F 480L WH NB-A3TG SD or equivalent approved make )

24

-

-

... More
Installation, testing and commissioning of 30m height high Mast lighting system with all accessories including design and supply of all materials, LED type single dome aviation obstruction lamps and casting of suitable shallow foundation with square footing using M-25 concrete for the mast considering the safe soil bearing capacity at site as 10 T/sq. mtr. at suitable depth, filling the basement of highmast foundation pit .Backfilling the excavated ground after casting the foundation, earthing and supply a set of steel foundation bolts manufactured from special steel along with nuts, washers anchor plates and templates for each masts. The erection of the masts should be done with the help of suitable equipment.

3

-

-

... More
GAS PIPING & MANIFOLD SYSTEM

-

-

-

... More
Dissolved Acetylene (DA) Piping

-

-

-

... More
Pipes In trenches/Undergroud area - Design, Supplying, installation, testing and commissioning of Seamless Carbon Steel Pipes, A106 Gr B, sch-40, complete including all fittings Fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. conforming to ASTM standard , fixing the pipe inside the trench with suitable clamps, supports and painting meeting the requirements of C5M as per ISO 12944 of required shade complete as required and clamps and jointing with Teflon tape including chase cutting and making good the walls, floors etc. wherever required, Pipe Hangers and all structural steel supports & as per tender technical specifications.

-

-

-

... More
80NB - Supply

72.6

-

-

... More
80NB - Installation, testing and commissioning

72.6

-

-

... More
50NB - Supply

26

-

-

... More
50NB - Installation, testing and commissioning

26

-

-

... More
40NB - Supply

10

-

-

... More
40NB - Installation, testing and commissioning

10

-

-

... More
32NB - Supply

181.5

-

-

... More
32NB - Installation, testing and commissioning

181.5

-

-

... More
25NB - Supply

55

-

-

... More
25NB - Installation, testing and commissioning

55

-

-

... More
20NB - Supply

7.92

-

-

... More
20NB - Installation, testing and commissioning

7.92

-

-

... More
Pipes above the ground level - Design, Supplying, installation, testing and commissioning of Seamless Carbon Steel Pipes, A106 Gr B, sch-40, complete including all fittings Fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. conforming to ASTM standard, fixing the pipe above ground level like on the wall/ceiling with suitable clamps, supports and painting meeting the requirements of C5M as per ISO 12944 of required shade complete as required.and clamps and jointing with Teflon tape including chase cutting and making good the walls, floors etc. wherever required, Pipe Hangers and all structural steel supports & as per tender technical specifications.

-

-

-

... More
80NB - Supply

219.34

-

-

... More
80NB - Installation, testing and commissioning

219.34

-

-

... More
50NB - Supply

243

-

-

... More
50NB - Installation, testing and commissioning

243

-

-

... More
40NB - Supply

10

-

-

... More
40NB - Installation, testing and commissioning

10

-

-

... More
32NB - Supply

100.1

-

-

... More
32NB - Installation, testing and commissioning

100.1

-

-

... More
25NB - Supply

11

-

-

... More
25NB - Installation, testing and commissioning

11

-

-

... More
20NB - Supply

10

-

-

... More
20NB - Installation, testing and commissioning

10

-

-

... More
10NB - Supply

5

-

-

... More
10NB - Installation, testing and commissioning

5

-

-

... More
Design, Supplying, installation, testing and commissioning of Ball valve of 3Pc Design: Full Bore: 150#: Flanged Ends: Body/End Connectors/ Ball - CF8: Stem -SS304: Seat/Seals - PTFE: Hand Lever Operated and tested to a pressure not less than 15 Kg/cm2 with flanged joints or socket weld joints complete with nuts, bolts, gaskets, washers etc. & as per tender technical specifications.

-

-

-

... More
20NB - Supply

65

-

-

... More
20NB - Installation, testing and commissioning

65

-

-

... More
Sub Manifold structure

-

-

-

... More
Design, Supply, Installation, testing and Commissioning of Sub Manifold structure of necessary size GI pipe with necessary isolation ball valve and 1/2'' flash back arrestor (FBA- 3m3/hr) at inlet and with 04 numbers of (1:8) tapered threaded bush fittings coupled with blind flanged connection and 04 numbers of LPG valve with spindle and hand wheel stub size 25.4 mm , outlet 5/8” BSP (L.H) with SS spindle and Teflon washer & as per tender technical specifications.

62

-

-

... More
Design, Supply, Installation, Testing and Commissioning of Manifold system for Acetylene storage area with the following components for 58 cylinders in operation and 58 cylinders in standby (2 x 58 Nos.) ; SS braided Teflon hose, main header, branch pipes, isolation valves, inline filter, Safety relief valve, SS body pressure gauges, regulator, high pressure and low pressure valves, flashback arrestor, Check valves, MS legs, support structural with clamp, anchor fastener or welding with paints, Suitable box clamp and Teflon tape and MS support with clamp with anchor fastener or welding with paints, Cylinder holding chain system, for the above required as per the statutory norms and standard & as per tender technical specifications.

1

-

-

... More
Design, Supplying, installation, testing and commissioning of of pressure gauge 0-200 PSI (0 - 14 Kg ) range, 3/8" BSP bottom entry, 4" dial weather proof with stainless steel internals, siphon tube and ball valve including fittings, etc. complete as required suitbale for LPG gas & as per tender technical specifications.

12

-

-

... More
Sub Total SH:1

-

-

-

... More
300 T Goliath Crane

-

-

-

... More
Supply of material, accessories and spares of 300T capacity 85 m span rail mounted gantry crane. Import supply: Includes cost of DDP HSL stores delivery after Custom Clearance, Local Transport from port to HSL, Transport from HSL to erection site, handling, loading/unloading, cost of spares to be supplied along with crane etc. to the complete satisfaction of Officer in charge/Engineer as per the technical specification attached. Indigenous supply, if any (INR): Includes cost of delivery at HSL stores all inclusive, Transport from HSL to erection site, handling, loading/unloading to the complete satisfaction of Officer in charge/Engineer as per the technical specification attached.

1

-

-

... More
Erection,Instalation,Testing,commsiosing and handing over of 300 T Capacity,85 m span rail mounted Gantry Crane and its Accessories..

1

-

-

... More
FIRE PROTECTION SYSTEM WORKS

-

-

-

... More
Supply, Installation, Testing and Commissioning of electric driven main fire pump suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification. (a) Horizontal split casing or Vertical inline, centrifugal type pump of Stainless steel body & Stainless steel impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest oulet at specified flow of 4500 lpm at 85m. head conforming to IS 1520. (b) Suitable HP/RPM Squirrel cage induction motor, TEFC, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads/ mounts.

1

-

-

... More
Supply, Installation, Testing and Commissioning of diesel engine driven fire pump suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification (a) Horizontal split casing or Vertical inline, centrifugal type pump of Stainless steel body & Stainless steel impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest oulet at specified flow of 2850 lpm at 120m. head conforming to IS 1520. (b) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete with auto starting mechanism, 12 volts/24 Volts electric starting equipment, 12v 180AH Battery and leads, Diesel Tank Fabricated from MS sheet of 4mm Thick (Minimum Capacity for 8 hour operation) with level indicator, By-pass line, piping from diesel tank to engine, exhaust pipe extended upto 1 m. outside pump house duly insulated with 50 mm. thick glass wool with 1.0 mm. thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. (c) M.S. fabricated Common base plate, coupling, coupling guard etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads/ mounts. (e) Diesel engine control panel.

1

-

-

... More
Supply, Installation, Testing and Commissioning of electric driven pressurisation pump (Jockey Pump) suitable for automatic operation and consisting of following, complete in all respect as required as per technical specification. (a) Vertical, centrifugal type pump of stainless steel body & stainless steel impeller with stainless steel shaft, mechanical seal and flow of 180 lpm at 85 m. head conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 2900/3000 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads .

1

-

-

... More
Supply, installation, testing and commissioning of non-return valve of following sizes having PN 16 rating complete with SS body, SS disc, rubber gasket, GI bolts, nuts, washers etc. as required as per technical specification and conforming to API 594.

-

-

-

... More
200mm dia - Supply

2

-

-

... More
200mm dia - Installation, testing and commissioning

2

-

-

... More
65mm dia - Supply

1

-

-

... More
65mm dia - Installation, Testing and commissioning

1

-

-

... More
Supply, installation, testing and commissioning of butterfly valve of following sizes having PN 16 rating with SS body, SS disc, EPDM seal complete with nuts, bolts, washers, gaskets conforming to IS 13095/API 609, complete as required as per technical specifications.

-

-

-

... More
200mm dia - Supply

2

-

-

... More
200mm dia - Installation, testing and commissioning

2

-

-

... More
150mm dia - Supply

15

-

-

... More
150mm dia - Installation, Testing and commissioning

15

-

-

... More
Supply, installation, testing and commissioning of pressure gauge (0 - 16 Kg/sq.cm) range, 3/8" BSP bottom entry, 150 mm dial weather proof with stainless steel internals including fittings, ball valve etc. complete as required as per technical specification.

4

-

-

... More
Supply, installation, testing and commissioning of industrial type pressure switch having 1/4" BSP(F) connection with IP rated enclosure protection, phosphor bronze bellows as sensing element, SPDT contact system for automatic purpose including fittings, ball valve etc. complete as required as per technical specification.

3

-

-

... More
Supply, installation, testing and commissioning of air vessel made of 250 mm dia 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories and painting with synthetic enamel paint of approved shade as required as per technical specification.

1

-

-

... More
SITC of Above ground M S ERW Heavy (Class C) Pipe as per IS:1239 Part-1 for 150mm dia and below & IS:3589 Gr.Fe. 410 with thk.6.35mm for 200 mm dia and above. Pipes for all sizes shall be provided with internal Poly- Glass coating of 1000 micron including cutting, screwing, welding etc. and providing all fittings (thickens of fittings shall be matched with parents pipes) like elbow, tee, reducer, companion flanges, All fittings shall be A234 WPB-W.All flanged valves shall be as per ASME B 16.20 and all gaskets shall be of metallic with SS316 spiral wounded CAF filler. All studs and nuts shall be SS 316 As per ASTM A 193. All ERW pipe with internal bead flushed fully with internal surface of pipe or maximum 0.2 mm projection or below throughout the length of pipe and flange fixing for Poly- Glass coating. Pipe to pipe joint shall be flanged type with Poly-Glass coating. External painting.of pipe shall be as per painting specification. Hume pipes, wrapping and coating to be provided where ever pipes are laying under ground.

-

-

-

... More
200 mm dia - Supply

16

-

-

... More
200 mm dia - Installation, testing and commissioning

16

-

-

... More
150 mm dia - Supply

950

-

-

... More
150 mm dia - Installation, testing and commissioning

950

-

-

... More
100 mm dia - Supply

60

-

-

... More
100 mm dia - Installation, testing and commissioning

60

-

-

... More
80 mm dia - Supply

33

-

-

... More
80 mm dia - Installation, testing and commissioning

33

-

-

... More
65 mm dia - Supply

5

-

-

... More
65 mm dia - Installation, testing and commissioning

5

-

-

... More
SITC of Above ground Seamless SS316L pipe as per ASTM-A-312, TP-316L, Schedule-40 including cutting, welding etc. and providing all fittings like elbow, tee, reducer, companion flanges, SS 316 nut- bolt, washer with gasket etc as per ASTM-A-403, WP-316L, Schedule-40 / ASTM- A-182, F-316, Class 3000#

-

-

-

... More
200 mm dia - Supply

16

-

-

... More
200 mm dia - Installation

16

-

-

... More
80 mm dia- Supply

8

-

-

... More
80 mm dia- Installation

8

-

-

... More
Supply,installation,testing and commissioning of gun metal fire hydrant valve, single head oblique type with 63 mm instantaneous outlets with female socket for hose connection and inlet side with flange suitable for 80 mm pipe flange,valve conforming to IS:5290 complete with blank cap,chain etc as per technical specification.

22

-

-

... More
Supply, installation, testing and commissioning of 4 way Fire brigade collective breaching with 150 mm flanged outlet connection and built in check valves complete as required as per technical specification.

1

-

-

... More
Supply, installation, testing and commissioning of EPDM Rubber Flexible connectors (Expansion Bellows) of following sizes complete complete with GI nuts, bolts, gasket etc. as required as per technical specifications

-

-

-

... More
200 mm dia- Supply

4

-

-

... More
200 mm dia- Installation

4

-

-

... More
65 mm dia- Supply

2

-

-

... More
65 mm dia- Installation

2

-

-

... More
Supply, installation, testing and commissioning of Stainless steel foot valve of following sizes complete complete with GI nuts, bolts, gasket etc. as required as per technical specifications

-

-

-

... More
200 mm dia- Supply

2

-

-

... More
200 mm dia - Installation

2

-

-

... More
65 mm dia - Supply

1

-

-

... More
65 mm dia - Installation

1

-

-

... More
Supply, installation, testing and commissioning of Gun metal Air release valve, 25 NB male thereaded inlet, complete with all accessories as required as per the technical specification.

2

-

-

... More
Supply and installation of ABC Stored pressure type Fire Extinguisher, 6 Kgs Capacity, Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2018 with ISI mark.

35

-

-

... More
Supply and installation of ISI marked (IS: 15683:2018), 4.5 Kg capacity Carbon-dioxide extinguisher made of high pressure seamless steel cylinder (CCE marked ) complete with wheel type valve with one meter long braided high pressure discharge hose with all accessories in all respects including initial fill with CO2 gas. complete as required as per the technical specification.

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.