To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

East Coast Railway - ECOR Tender

Works
Telecommunication Services
Ireps
Opening Date16 Jul 2024
Closing Date6 Aug 2024
Tender Amount₹ 31,09,617.5 
Notes
Download

Costs

Summary

1. S&t Portion Of Work In Connection With Provision Of 12 M Fob At Jdb & Jyp Stations Under Amrit Bharat Scheme. 2. Replacement Of Existing Pd Mux,

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation of trenches including clearing of roots of trees etc., in rocky area up to a depth to be indicated by Railway Engineer at site as per the site condition [Minimum 0.6 meter] and width 0.3 Mts. at the 4 bottom. This includes concreting & plastering as per the instructions of site Engineer and complete back filling by digging earth from a lead of 30 Mtr. In case 0.8 meter depth or higher is achieved no concreting is required, otherwise concreting up to 100 mm thickness should be done. All materials required for the above works shall be supplied by the Contractor.

50

255

12750

... More
Excavation of trenches in all kinds of soils including soft rocky area and clearing of track etc. to a depth of 1.0 M and width of 0.3 M for track crossing /pucca road/level crossing gate/platform/station circulating 5 area or any other place as advised by site Engineer including transportation and laying of DWC/RCC/Split RCC/G.I. pipes with or without coupler. This includes repairing of track/pucca road/level crossing gate/ platform/station circulating area surface to original position by ramming and concreting wherever required soon after the work is over. DWC/RCC/GI pipes shall be supplied by the Railway. DWC pipes wherever required shall be supplied in 6 Mtr. length and shall be cut to size as per requirement. All other materials including cement are to be supplied by the contractor.

60

335

20100

... More
Cutting of masonary floor/walls at station building/ signal goomty/ Gate lodge at a depth of 0.5 mtr. 6 to 1.0 mtr a t places to be indicated by site Engineer for entering of cables inside the building. Only G.I pipes supplied by Railway and all materials as clamps, bolts & nuts as instructed by site Engineer supplied by tenderer. This includes repairing of masonary floors/walls after the cables are taken inside. Cement, Sand required for the work shall be supplied by the tenderer and also transportation of G.I Pipe from Store by the tenderer.

4

6108

24432

... More
Massonary chase cutting 3/2" X 3/2" at work site plastering of PVC pipe in the chase, drawl of 2/5/10/20/50 pair switch board cable through it, covering and plastering the chase with contractor's cement. All materials required for the work are to be supplied by the contractor.

100

406

40600

... More
Trenching and fixing of G.I. pipes of different sizes/DWC pipes in hard rocky area up to a depth of 0.3 M to 0.6 M or at places as per instruction of site Engineer and concreting [1 : 3 : 6] up to height of 100 mm above the pipes. G.I. pipes with the socket/ DWC pipes shall be supplied by the Railway. All other materials 8 required for the works shall be supplied by the contractor. Note: [1] In case of girder bridges, G.I. pipes shall be suitably clamped by the contractor as advised by the site Engineer. Clamps shall be supplied by the contractor. [2] The work including excavation of trenches in hard rock area up to a depth of 0.3 M to 0.6 M and back filling, ramming after completion of work where ever required. [3] In case of concrete bridges clearing of ballast for laying of pipes and re arranging the Railway ballast after completion of work shall be done by the contractor.

96

533

51168

... More
Transportation, excavation of pit, casting of foundation, plastering and erection of Steel Apparatus case (Half size) with fixing of E-Type lock, wiring, cable entry, termination clamping, filling cable pit with sand, painting and lettering etc., as per Drg.No. S&T/Con/BBS/92/90. This includes earth work and/or masonry work required for securing the apparatus case as per site condition. Railway will supply apparatus case with 'E' type lock only. Tenderer shall supply all wiring materials, PBT Terminals, fuses, fuse blocks, bus bars, hylum sheet ISI 9 mark [6mm thickness], wood plank board of good quality [minimum 3/4" thick, cement and any other materials that are required for the work at his own cost. Contractor has to transport all the materials from store at his own cost to the work site. The wiring materials such as wire coils, PBT terminals, fuses, fuse block, etc. should be used from RDSO approved sources. 1) Modifiaction of inside arrangement of Apparatus cases if required for fixing of relays/transformers etc. shall be done by the contractor. Extra shelf, if any, shall be deposited to the Railway stores by the contractor. 2) All cables shall be terminated by providing copper eyelet of suitable size. Note:-(i) If location box foundation is available at site 20% of the cost is to be deducted.(ii) 40% payment shall be released after erection of location boxes.

2

9742

19484

... More
Concreting (Mix 1:2:4) 200 mm x 200 mm on G.I. Pipes on bridges/ culverts or any other location as specified by the Rly. supervisor. All materials including cement required for the above works are to be supplied by the tenderer.

200

339

67800

... More
Fixing of aluminium/Krone type CT Boxes/rossetts and termination on following PIJF/U/G cable, SB cables in cable termination box including all other works required for cable termination. This includes plumbing of cable, painting, cementing & lettering of CT box.

40

481

19240

... More
Excavation of trench of size 15cm X 30cm on platform with cutting machine and laying of cables through CPVC/G.I. pipe of required size at site duly removing the existing platform surface such as shabad stone, granite etc., without damaging.The surface of the platform to be restored to its original shape after completion of 1 work. In case of platform surface stones are damaged, the contractor has to arrange to for the stones/tiles of similar type at his own cost.During digging, all precautions to be taken to avoid inconvenience to the travelling public.The work is to be carriedout preferably when the platform is free from occupancy protection barricading arrangement has to be done on platform till the work is completed. All materials including CPVC/GI pipe has to be arranged by the contractor as per the site condition.

500

433

216500

... More
Laying and drawing of Data communication cable through 25 mm PVC conduit pipe. As per instruction of site Incharge.

250

9

2250

... More
Laying and drawing of Power cable through 25 mm PVC conduit pipe. As per instruction of site Incharge.

250

15

3750

... More
Fixing of PVC conduit pipes firmly with wall and ceiling sealing with PVC saddles at regular interval of 50 cm.

2940

2

5880

... More
Excavation of pit, execution of jointing of Telecom cable by using Thermo shrink cable jointing kits 5 for straight through derivation joints and covering of cable jointing kits with excavated soils and ramming. Jointing kit shall be supplied by the Railway. All other materials required for execution of work shall be supplied by the contractor.

10

1640

16400

... More
Supply of High Power, Electronic Cable Route Tracer/ Pipe and Cable locating kit with 36 user configurable Active multi frequency options including 200Hz, 512Hz, 797Hz, 815Hz, 8kHz, 33kHz, 65kHz, 82kHz, 200kHz upto 476.2kHz, passive detection @ 50Hz for power cables, Radio Mode for locating metallic utilities 1 whether energised or not, Current measurement, LCD Display with left-right arrow function , Modes: peak, peak with arrow, pin point peak and null modes, Compass function; Depth measurement. Supply includes locating receiver, Transmitter (Max power : 12Watt) with Li-ion Rechargeable Batteries for both Transmitter & Receiver, Battery charger, Induction Signal Clamp 4'', supplied in a carry bag. Similar to 3M-Dynate/Radio detection/Stanlay Pathfinder LOC10. Inspection by RITES.

2

379188

758376

... More
Supply of Screened cable 2 core with PVC pipe (Thickness 2mm, dia 25mm). Inspection by the Representative of Railway.

400

44

17600

... More
Supply of double walled corrugated pipe 6 mtr in length, 120 mm outer dia and 103 mm inner dia, 3 with one suitable coupler conforming to RDSO Specification No. RDSO/SPN/204/2011 Version 1.1 Amdt 1 or latest for under ground cable protection . Colour-Orange. Inspection by the Representative of Railway. Note: If required, the DWC pipe shall be supplied split in two halves.

10

4117

41170

... More
Supply of Perforated G.I. pipe of 100 mm dia with socket. G.I. pipe of make TATA/JINDAL shall be as per IS: 1239 part-I/2004 Specification for medium gauge and shall be perforated by drilling 7 mm dia holes length wise in zig-zag manner staggered at a distance of 300 mm. Inspection by the Representative of Railway.

96

1889

181344

... More
Supply of Steel Apparatus case 'Half Size' as per Drg.No.S&T/CON/BBS/92/90 with 'E' type lock & Key. Ward No. 32. Inspection by the Representative of Railway.

2

25868

51736

... More
Supply of 100 Pair Krone CT Box with LSA plus disconnecting modules, Make- M/s Krone Communication Bangalore. Inspection by the Representative of Railway.

40

4389

175560

... More
Supply of VF Transformer bay rack mounted, U-link panel 06 no.s and 100 pair Krone module 02 no.s to be accomodated in a rack that use for Railways in Electified areas. Inspection by the Representative of Railway.

10

47200

472000

... More
Supply of 5 pair colour coded and PVC insulated twin twisted overall and pair shielded data 1 communiaction cable (7 strands of min 0.3 mm dia). Generally confirming to DIN VDE 0815 except for colour code of cable pair which shall be as per DIN BDE 0816 or latest. Inspection by the Representative of Railway.

250

44

11000

... More
Supply of PVC insulated flexible 3 core X 2.5 sq mm multi strand power cable as per Spec No. IS 694:1990 reaffirmed 1995 or latest. Inspection by the Representative of Railway.

250

38

9500

... More
Supply, installation, testing and commissioning of Maintenance free and permanent earth as per RDSO Specification No. RDSO/SPN/197 Version 1.0 and Technical Specification as per section H, Chapter 8. Inspection by the Representative of Railway.

8

61717

493736

... More
Supply, Transportation and Installation of earth electrode (make TATA or Jindal as per Rly. practice) including MS flat for signalling equipments on lever frame, apparatus cases, signal, relay racks, cable termination rcak, block instrument etc. (supply & installation of earth electrode as per drawing no. RE/S&T/DRG/Tender/SK/398/94 for apparatus cases, signal post & other equipments as per instruction on 2 earthing of S&T equipment. Laying of earth lead mild steel flat of size 35mmx6mm and fixing of lead MS flat (make TATA/Jindal or Similar) to earth electrode and lever frame, signal post & apparatus cases as per Drg. No. CORE/S&T/ALD/SK/591/2008, 592/2008 and 593/2008 respectively and instructions on earthing at S&T equipment and providing cement enclosure for earth electrode as per drawing no. RE/S&T/Sig./Tender/SK/13/85 Alt. A) NOTE: This includes testing of earth value and indicating the same on the Earth enclosure by paint. Inspection by the Representative of Railway.

2

12306

24612

... More
Supply, Installation and Commissioning of 5 KVA Online UPS with Two Hours back up as per Technical Specification in Annexure-II, Inspection by Representative of Railway.

2

85550

171100



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.