East Coast Railway Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

East Coast Railway Tender

Works
Telecommunication Services
Ireps
Opening Date4 Sep 2024
Closing Date5 Nov 2024
Tender Amount₹ 1,12,59,24,297 
Notes
Download

Costs

Summary

Survey, Design, Supply, Installation, Testing And Commissioning Of Kavach Equipments And Other Associated Works Between Duvvada(dvd) - Palasa(psa) Section Of Waltair Division Of East Coast Railway.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply (Including 10% Spares) , Installation & Commissioning of station TCAS RIU (Remote 4 Interface unit) with atleast 64 Field I/P's as per RDSO/SPN/196/2020 Version 4 or latest . The RIU should have provision of OFC OR Quad Interface and should be connected to central TCAS in a Ring network .This includes supply and installation of all modems, OFC termination box for required fibres, interface, Earthig, Wiring & Signal functions etc. Supply of earthing material and supply of relays is covered separately. Inspection by RDSO.

63

1505659

94856517

... More
"design and drawing of a comprehensive Kavach system for modifications to existing EI/PI/RRI stations, LC installations, and IBS systems in accordance with the revised approved SIP."

50

10000

500000

... More
Supply, Installation, Programming, Verification and Commissioning of RFID tags with enclosures and fixures at Stations and block sections(absolute/Automatic Block section). This should comply to RDSO/SPN/196/2020 Version 4.0 or latest. Inspection by RDSO.

8000

16000

128000000

... More
Supply of kit for configuring, programming and downloading RFID Tag data as per RDSO issued guidelines. Inspection by RDSO.

3

1304905

3914715

... More
Supply, installation and commissioning of Test Bench for Station TCAS equipment as per RDSO/SPN/196/2020 Version 4.0 or latest. Inspection by RDSO.

1

2549583

2549583

... More
Supply, installation and commissioning of Network Management System for Centralized monitoring of TCAS station and Loco equipment as per RDSO/SPN/196/2020 Version 4.0 or latest. Inspection by RDSO.

1

9289248

9289248

... More
Supply, Installation and commissioning of kit for configuring, programming and downloading execution and application data for Stationary Station TCAS equipment. Inspection by RDSO.

3

355269

1065807

... More
Supply, Installation and commissioning of Lab Models of station equipment, loco equipment, trackside components and simulator at Headquarters etc as per RDSO/SPN/196/2020 Version 4.0 or latest. Inspection by RDSO.

1

9473850

9473850

... More
Training to Railway staff for each training package of 300 man-days

1

752829

752829

... More
Application Safety Case for entire work.

1

10516130

10516130

... More
Fixing of RFID INDICATION BOARD near RFID sleeper with contractors own material and painting Red Stripes on RFID sleeper, As per drawing No.KAVACH/RFID/sleeper/2024. The work shall be done as per instructions of Rly engineer at site. Inspection by consignee.

10000

442

4420000

... More
Testing commissioning of TCAS system in the entire system.

1

15729945

15729945

... More
Supply(including spares), Installation & Commissioning of Locomotive (on board) TCAS Equipment 17 consisting of Vital computer & pheripherals such as Driver Machine interface, 2 RFID Readers, 2 full duplex Radio modems, 4 LTE compatible antenna, 2 GPS and GSM antenna, two number of pulse generator/wheel sensor with direction sensing, and associated cable and power supply arrangement excluding Brake interface unit. This should comply to RDSO/SPN/196/2020 Version 4.0 or latest. Inspection by RDSO.

5

5821883

29109415

... More
Supply, Installation & Commissioning of Brake Interface unit suitable for different locomotives as per RDSO/SPN/196/2020 Version 4.0 or latest. Inspection by RDSO.

5

1927243

9636215

... More
Supply and installation of Video Surveillance cameras including Audio recording in each Loco with a set of four cameras along with system incl. wiring(Comprises 2 cameras with long distance coverage of at least 300mts and 2 cameras with a coverage of at least 10 mts) of 15 days memory storage. Inspection by consignee.

5

43589

217945

... More
Preparation and Supply of Training e-learning Manuals for On-Board and Trackside System. This 20 need to meet requirements of Railways (EMU & DEMU each one set). Inspection by consignee.

2

175269

350538

... More
Supply of station TCAS Equipment with suitable Rack consisting of Vital computer peripherals, 2 full duplex Radio modems, OFC modems, UHF antenna, GPS and GSM antenna and interfaces as per RDSO/SPN/196/2020 Version 4.0 or latest. Inspection by RDSO.

4

3130596

12522384

... More
Supply of RFID tags. Inspection by RDSO.

500

12800

6400000

... More
Supply of station TCAS RIU (Remote Interface unit) with at least 64 Field I/P's as per RDSO/SPN/196/2020 version 4.0 or latest. The RIU should have provision of OFC or Quad Interface and should be connected to central TCAS in a Ring network. Inspection by RDSO.

15

671058

10065870

... More
Re-programming, Re-fixing and verification of existing RFID Tags

500

4700

2350000

... More
Re-programming of existing RFID Tags without shifting

500

2000

1000000

... More
Supply, transportation, erection, and grouting of Composite Relay Racks / Relay Racks /CT racks as per Drg.No. SK/DRG/OL/SER/192, SH-1/2 (for Composite Relay Racks), Drg.No. SK/ DRG/OL/SER/192, SH-2/2 (for Relay Racks) and Drg.No. S&T/CON/HQ/VSKP/95/92 (for CT Racks) respectively, including fixing of racks, 1 PBT terminals 1-Way/6-Way, ND Fuses, Bus Bars, Eyelets, Hylum strips of required thickness [12 mm] as per length required at site, condensers and resistances etc., wherever required as per directions of Site Engineer. Inspection of Composite Racks / Relay racks/CT racks by Representative of Railway before use. Tenderer shall supply all the materials from RDSO approved sources such as PBT terminals 1-Way/6-Way, ND Fuses, Fuse blocks, Bus Bars, Eyelets, Hylum strips (12 mm thickness ISI Mark) condensers and resistances etc., and any other materials required for the work at his own cost. Inspection by consignee.

195

96053

18730335

... More
Fabrication and supply of MS frames to suit- Q'series relays to accommodate 6 No in each set as per Drg.No.B .SG.CN. MlSC.9.98 duly drilling required holes for relay bases( All materials such as frames, bolts, nuts and washers to be supplied by the contractor. Inspection by consignee.

1077

513

552501

... More
Supply and fixing of aluminum ladder of width 0.3 mtr consisting aluminum angles both sides of 3 37mm*25mm*2mm and placing the aluminum bar with a gap of 20cm having all of thickness 37mm*2mm dia. The aluminum ladder will be supported by at a gap of .3mtrs by aluminum angle 50mm*50mm*4mm (this includes all fittings, jamming, cementing. rivets, corners, bolts and nuts as per the site requirement including supply of cement and other necessary materials). as per instruction of site Engineer. Inspection by consignee.

1350

1801

2431350

... More
Supply, installation, testing and commissioning of Maintenance free and permanent earth as per RDSO Specification No. RDSO/SPN/197 Version 1.0. Inspection by RDSO.

315

61717

19440855

... More
Supply and Installation of OFC joint enclosure and splicing of Optic fiber cable (48 fibres) and testing 5 as per technical nspecification No.GROJC-2/02 sept 2003. Supply of splice enclosure (24 fiber) shall be as per Boards specification of TEC. All materials including fusion splicing machine used for fiber splicing and OTDR for testing and other testing materials if any shall be arranged by the contractor. Inspection by consignee.

5

17783

88915

... More
Supply and installation of rack mounted 48F FDMS fiber part no.fms-1u 48FS 48FP Raychem make 6 including 48Nos 0.2db FC/PC adaptors and 24numbers 900 micron 1.5 meter FCPC pigtails. RDSO Spec No.: RDSO/ SPN/TC-037-2000 (Ver.3) or latest. Make 3M model or similar (latest version). This includes transportation, installation and testing. Inspection by consignee.

46

34220

1574120

... More
Supply, transportation, and installation of RCC joint chamber with two piece top cover and bottom 7 cover with hole for drainage and cable entry as per drawing No.RCIL/ER/DRG-02/06 (Section-H). This includes trenching for joint pit, back filling and ramming of pit after placing the joint closure and cable loop in the chamber without causing damage to the same and consolidation of soil as well as disposal of excess soil. Inspection by consignee.

5

11156

55780

... More
Supply and fixing of 'MS-C' channel of size 100mmX50mmX1200mm with suitable clamps as per 9 drawing No. S&T/RE/78/2/76 and fitting to GI pipes of 50/65mm of spec.IS-1239/part-1/ Light with couplings and with suitable clamps on Girder bridges without drilling holes in the girders. GI pipes are to be drilled with 6 holes of 1/4" dia. per metre around the pipe in zig-zag manner before laying the 6metres GI pipe. the MS Channels shall be inspected by the office in charge of the work before fixing. Inspection by consignee.

150

863

129450

... More
Supply & Laying of G.I Pipes 50mm dia. medium quality to specification IS.1239 (part-I) 1990 and 10 galvanised to specification IS.4736-1986 On bridges , culverts, trench with channel ramps on either end of the culvert/bridges. Clamping arrangement with MS brackets for fixing of GI pipes on bridges/culverts, small holes of 5mm are to be drilled on the pipe before laying of the pipes. Inspection by RITES.

750

680

510000

... More
Supply and Installation of RFID based Electronic /Pipe marker (route marker) for S&T Cable with programmable memory for saving the user specific data which can be buried up to depth of 1.5 Meter. Make Stanley/3M or Similar. Inspection by consignee.

240

2814

675360

... More
Supply, Transportation and Installation of earth electrode (make TATA or Jindal as per Rly. practice) including MS flat for signalling equipments on lever frame, apparatus cases, signal, relay racks, cable termination rcak, block instrument etc. (supply & installation of earth electrode as per drawing no. RE/S&T/DRG /Tender/SK/398/94 for apparatus cases, signal post & other equipments as per instruction on earthing of S&T 12 equipment. Laying of earth lead mild steel flat of size 35mmx6mm and fixing of lead MS flat (make TATA/Jindal or Similar) to earth electrode and lever frame, signal post & apparatus cases as per Drg. No. CORE/ S&T /ALD/SK/591/2008, 592/2008 and 593/2008 respectively and instructions on earthing at S&T equipment and providing cement enclosure for earth electrode as per drawing no. RE/S&T/Sig./Tender/SK /13/85 Alt. A). Inspection by consignee. NOTE: This includes testing of earth value and indicating the same on the Earth enclosure by paint.

230

12306

2830380

... More
Supply, installation and commissioning of SMPS based 110V/24-32V DC-DC converters containing 4 no. of 24-32V, 5 Amps DC/DC converter (internal (1+1), external (1+1)). Inspection by RDSO.

430

67150

28874500

... More
Erection of Relay rack 1way/2way/4way with scaffolding (2 way rack) suitable concreting tri-pod bases using j bolts, fixing rack supporting of size 50x50x6 mm on the wall. Reel insulators are to be provided for insulting the rack from the scaffolding & tri-pods.(payment based on number of equivalent 1 way relay rack)

70

595

41650

... More
Wiring and testing of complete Relay Rack / CT Rack / Composite Relay Rack as per wiring diagram for maximum number of plug in type relay & shelf type relays of different sizes or as directed by Railway Engineers 2 at site. This includes rack to rack wiring through MS ladder fixed on the top of the relay rack, crimping eyelets in the terminals fitted in the cables termination rack, numbering by ferrules 2.5 sq. mm, bunching of wires by bunching Tape/Thread and buttons, painting and lettering as required. Wiring of the racks shall be done with PVC wire of size 16/0.2 mm and 3/0.75 mm. Tenderer shall supply all wires & wiring materials purchased from RDSO approved sources.

195

158351

30878445

... More
Fixing of relay bases and wiring, bunching, fixing of relays, wiring in Old relay racks/location box and 3 also carrying out any alteration in existing relay rack duly wiring and connecting New to old and Old to old relays by standard wires (RDSO Approved Sources) as per Circuit diagram. Fuses of bases, condensers, ND fuses, LED indicator & its wiring for relay rack. All materials required for this work will be supplied by the contractor from RDSO Approved Sources. Relays with accessories will be supplied by the Railway.

5500

783

4306500

... More
Transportation, excavation of pit, casting of foundation, plastering and erection of Steel Apparatus 4 case (full size) with fixing of E-Type lock, wiring, cable entry, termination clamping, filling cable pit with sand, painting and lettering etc., as per Drg.No. S&T/CON /SK/16. This includes earth work and/or masonry work required for securing the apparatus case as per site condition. Railway will supply apparatus case with 'E' type lock only from Railway stores at. Tenderer will supply all wiring materials, PBT Terminals, fuses, fuse blocks, bus bars, hylum sheet ISI mark [6mm thickness], wood plank board of good quality [minimum 3/4"" thick, Cement and transport all the materials to site of work at his own cost. The wiring materials such as wire coils, PBT terminals, fuses, fuse block, etc. should be used from RDSO approved sources. 1) Modifiaction of inside arrangement of Apparatus cases if required for fixing of relays/transformers etc. shall be done by the contractor. Extra shelf, if any, shall be deposited to the Railway stores by the contractor. 2) All cables shall be terminated by providing copper eyelet of suitable size.

230

19438

4470740

... More
Numbering location box as per standard practice and writing all termination particulars inside the location box as per details. This includes all main and tail cable particulars, writing of cable numbering of cables, polishing teak wood boards in two coats and painting hard wood shelves in two coats of black enamel

230

488

112240

... More
Straight through / derivation with / without transformer joints: Installation Thermo shrinkable jointing 6 kits for straight through / derivation joints for LC gate where VF transformers are not required and derivation by using 2T transformer ( to be housed in the joint). This includes tapping of nominated quad at a specific location shown by the Railway Engineer at site to the jelly field cable already laid. All material including valco tapes except thermo shrinkable jointing kit shall be supplied by the contractor. Per

18

1707

30726

... More
Fixing relay bases, wiring in location boxes, bunching, fixing of relays as per circuit diagram. This includes fixing of condensers, resistance, 6 way / 1 way terminals/ WAGO, ND type fuses, LED indicators for fuses as per type fuses, LED indicators for fuses.

1945

272

529040

... More
Earthing and soldering of cable armour. (Unit - Per Cable)

204

22

4488

... More
Miscellaneous arrangements for any other SOR 2022 items of ECOR as per the instructions of engineer in charge

1

522700

522700

... More
Excavation of trenches of 1.2 Meter depth and width 0.3 Meter detailed below including clearing of roots and trees etc. for all types of soil. This work also includes covering of cables laid in trench and backfilling, 12 ramming, consolidation o f soil as well as disposal of extra soil after cable is laid as specified in Guidelines on Signalling Cable laying given by RDSO and any latest circular issued by CSTE/ECoR/BBS. Note: Before refilling of the trenches, the cable laid are to be tested and recorded for its insulation value and after satisfaction of site Engineer the refilling process should start and after monsoon the route is to be attended for backfilling the rain cuts, wash out of soils where ever found.

3

106669

320007

... More
Excavation of trenches of 1.0 Meter depth and width 0.3 Meter detailed below including clearing of roots and trees etc. for all types of soil. This work also includes covering of cables laid in trench and backfilling, 13 ramming, consolidation o f soil as well as disposal of extra soil after cable is laid as specified in Guidelines on Signalling Cable laying given by RDSO and any latest circular issued by CSTE/ECoR/BBS. Note: Before refilling of the trenches, the cable laid are to be tested and recorded for its insulation value and after satisfaction of site Engineer the refilling process should start and after monsoon the route is to be attended for backfilling the rain cuts, wash out of soils where ever found.

6

88821

532926

... More
Excavation of trenches of 0.8 Meter depth and width 0.3 Meter detailed below including clearing of 14 roots and trees etc. for all types of soil. This work also includes covering of cables laid in trench and backfilling, ramming, consolidation o f soil as well as disposal of extra soil after cable is laid as specified in Guidelines on Signalling Cable laying given by RDSO and any latest circular issued by CSTE/ECoR/BBS. Note: Before refilling of the trenches, the cable laid are to be tested and recorded for its insulation value and after satisfaction of site Engineer the refilling process should start and after monsoon the route is to be attended for backfilling the rain cuts, wash out of soils where ever found.

3

71060

213180

... More
Horizontal direction drilling/boring without damage of surface of road/Track formation. The bore shall be 150mm dia & shall be at the proper depth as per site condition decided by engineer in-charge. The ground 15 level shall be considered ignoring the bank height of the bank of the Road. The length of the bore shall be minimum 4mtrs long. This include insertion of different dia DWC pipe GI/HDPE pipes coupling etc. as per as per direction of Engineer In-charge. Note: The cost of pipe is not included in this item. Contractor shall provide all materials required for boring and adequate no of labour for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Per Track

1600

1486

2377600

... More
Cutting of rock up to a depth of 300mm and width of 300mm

75

802

60150

... More
Excavation of trenches including clearing of roots of trees etc., in rocky area up to a depth to be indicated by Railway Engineer at site as per the site condition [Minimum 0.6 meter] and width 0.3 Mts. at the 18 bottom. This includes concreting & plastering as per the instructions of site Engineer and complete back filling by digging earth from a lead of 30 Mtr. In case 0.8 meter depth or higher is achieved no concreting is required, otherwise concreting up to 100 mm thickness should be done. All materials required for the above works shall be supplied by the Contractor.

1500

255

382500

... More
Transportation of OFC from the store of to work site with care, and pushing/ pulling OFC through 19 the HDPE pipes sealing of the duct by simple plugs. The cable is to be laid by mechanised means. At inaccessible places where mechanised laying is not possible, the cable is to be laid manually by pulling through pre inserted rope. Empty cable drums with or without leftover cable should be returned to the store. This also includes testing of cable drums by OTDR in the store premises before transportation and submission of results thereof.

12

25563

306756

... More
Breaking of RCC concrete in Relay Room / Panel Room for drawing cables.

130

6485

843050

... More
Track crossing by horizontal boring method.

750

3902

2926500

... More
Excavation of trenches in all kinds of soils including soft rocky area and clearing of track etc. to a depth of 1.0 M and width of 0.3 M for track crossing /pucca road/level crossing gate/platform/station circulating area or any other place as advised by site Engineer including transportation and laying of DWC/RCC/Split RCC/G.I. 22 pipes with or without coupler. This includes repairing of track/pucca road/level crossing gate/ platform/station circulating area surface to original position by ramming and concreting wherever required soon after the work is over. DWC/RCC/GI pipes shall be supplied by the Railway. DWC pipes wherever required shall be supplied in 6 Mtr. length and shall be cut to size as per requirement. All other materials including cement are to be supplied by the contractor.

750

335

251250

... More
Jungle cutting along with the cable route and near towers

150

7

1050

... More
Laying of different cables in trench (signalling/4 quad/6 quad/power cable/telecom cables/jelly filled cable of all sizes in excavated trench through GI/RCC/DWC pipe etc. This includes transportation of cables from 24 the store to work site and transportation of empty cable drums with left over cable coil for termination purpose. Note-The cables are to be carefully handled during loading, unloading and transportation to work site. Any damage found in the cable after final testing, in view of mishandling of cables, shall be made good by the tenderer. Cable should be meggered before and after laying and recorded in a register and submitted to the site engineer.

222

24389

5414358

... More
Breaking of metal/tar road and refiiling after laying of cables as per drawing no. SDO/CABLE LAYING 010. The surface of road shall be concreted to match the old surface

350

248

86800

... More
Excavation of trench at the culvert from foot to top of it in the ramp to a size of 300mm width, 800mm depth by storing the ballast and excavates soil separately laying o f the HDPE/DWCpipe uaing couplers and bends as per d rawingNo.SK.15/11, drawing of cables through the pipe and refilling of the trench duly putting back the removed ballast in its proper shape and place.

250

139

34750

... More
Digging of cable pit for the required depth and width to locate the cable at specific location etc.

30

2950

88500

... More
Design of cable route plan, as per technical specification and supply of 6 sets of documents in 28 proper binding from approved drawings shall be taken and submitted to Railways. This includes (but not limited to) circuit diagram, RFID Tag-TIN layouts, Table of Control for entire section, Stationary and Loco TCAS interface diagrams, power supply diagram and other manuals as specified in the tender document

25

145990

3649750

... More
Site survey for tower erection RSS Signals strength measurement, study of braking characteristic of 29 electric /diesel loco, submission of drawings for installations of train borne and track equipments, design and installation of proto track equipments, design and installation of proto type for approval and obtaining approval of the same for radio survey.

1

3822468

3822468

... More
Aerial videography by unmanned Aerial vehicle (UAV-Drone). This will give entire track profile for placement of RFID tags and mapping of absolute location for signals etc. Per Track

220

14530

3196600

... More
Transportation of HDPE pipe from the store to work site, laying of the same (With 4 mm nylon rope, 33 pre inserted inside the HDPE pipe) in excavated trench/ already laid GI/ RCC pipe / tubes, jointing, leveling and end sealing the pipes, HDPE pipe, couplers and end caps shall be supplied by Railway, Nylon rope shall be supplied by the contractor.

12

15746

188952

... More
Supply of Injection-molded cable channel of size width (int/ext) 240/340 mm height (int/ext) 155/230 34 mm , Length 1 Meter ( 10mm), weight per meter 8 Kg (Top and Bottom). Material Polyolefin Engineering Plastic with fire protection class V0 following DIN - 53438 Part II, for laying Signalling / Telecom Cables. As per RDSO Technical Specification STS/Cable - Laying practices Vol - IV, Dt. 09.05.2018 in DIN 53438 Parts - II.

10000

3100

31000000

... More
Hiring of Vehicle for execution of the TCAS Project (Monthly basis cab & Taxi Hiring services-SUV; 3000 KM per month outstation 24*7)

3

952788

2858364

... More
Hiring of Skilled Labour assistance SE/JE in day to day works i.e. assisting for exact fixing of RFID 1 tags, TCAS units, identifying ECR/ECPR contacts, static and dynamic testing, taking of measurements, nothing of daily work status, carrying the tools & equipments etc watch & ward during the course of execution of work as per the instructions of concerned SE/JE (as per chief labour commissioner letter No.1/131/1/2016-LS-II dt:31.3.16)

1775

1039

1844225

... More
Hiring of Unskilled Labour assistance SE/JE in day to day works i.e. giving marking of cable route, 2 cable laying, taking of measurements, noting of daily work status, carrying the tools & equipment etc., watch & ward during the course of execution of work as per the instructions of cenerned SE/JE (as per chief labour commissioner letter No.1/131/1/2016-LS-II dt:31.3.16)

1775

785

1393375

... More
Supply of 48 Fibre armoured OFC as per RDSO spec No. RDSO/SPN/TC/110/2020 or latest. Inspection by RDSO.

12

122720

1472640

... More
Supply of Permanently lubricated two layer type HDPE duct, outer dia 40 mm, inner dia 33 mm with 2 three end plugs and two couplers for every Km length of pipe in length of 500 m confirming to RDSO Spec. No. ROSO/SPN/TC/45/2013 .Rev.2.0 Amendment 2.0 or latest.Inspection by RITES. Note:- The HDPE duct should be pre inserted with 4 mm nylon rope, inside the HDPE duct. Inspection by RDSO.

12

138511

1662132

... More
Supply of Cable 12 core Un Screened, PVC insulated, Armoured, Under Ground railway signalling cable (copper conductor) 1.5 Sq.mm, RDSO specification No. IRS:S:63/2014 (Rev 4.0) or Latest. Inspection by RDSO.

120

217114

26053680

... More
Supply of Underground Railway jelly filled 6 Quad cable with spec no. IRTS 30-2005 Ver 1. with amen. 1 to 5 or latest of size dia 0.9mm in drums of 1 km. Inspection by RDSO.

30

285678

8570340

... More
PVC insulated, armoured, Unscreened underground Power cable alluminium conductor, size 2C x 25 sq. mm confirming to specification No. IRS. S.63/2014 and IS.1554 part I ( Rev 4.0) or latest. Inspection by RDSO.

30

106811

3204330

... More
Supply of under ground, armoured, unscreened railway power cable, copper conductor of size 2X10 Sq mm as per RDSO specification no-IRS:S-63/2014 and IS:1554 (part-I)(Rev.4.0) or latest. Inspection by RDSO.

30

172846

5185380

... More
Supply of 35 Sq.mm Multi-strand single core PVC insulated copper cable as per IS:694 for connecting Main earth electrode to MEEB in the equipment room in duplicate. Inspection by consignee.

7469

509

3801721

... More
Supply of Relay, Non-AC immune plug in type, style QN1, DC neutral line, 24 V, 12F.4B contacts, 8 front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS: 930, IRS S34 & IRS: S 23 (as applicable) The interlocking code for this unit shall be ABCDF (with ATC clips). Inspection by RDSO.

3150

6471

20383650

... More
a] Supply of Relay Non-AC immune , plug in type, style QN1, neutral line, 24V or 50V DC, 8F/8B 9 contacts metal to carbon with plug board, retaining clip and connectors confirming to BRS: 930, IRS: S - 34 and IRS: S - 23 (As applicable). The interlocking code for this unit shall be ABCDF for 24V and ABDEF for 50V. Inspection by RDSO.

1650

6190

10213500

... More
Supply of Relay AC immune, plug-in-type Style 'QNA1, DC neutral line, 24V, 12F.4B contacts, front and back contacts metal to carbon with plug board retaining clip and connectors confirming to BRS 931A, IRS-S60, IRS-S34 and IRS-S23 (as applicable). The interlocking code for this unit shall be ABDFH.(Inspection by RDSO)

428

6720

2876160

... More
Supply of 2 way Relay Rack universal type as per drg no S&T/MFT/291 with scaffolding, POWER 11 COATED with stainless steel nuts and bolts for fixing the rack. Supporting angles, frame mounting triangle base with J bolts and insulation required numbers complete to suit QN1/K-50 wired tag blocks with suitable internal frame. Inspection by consignee.

68

17257

1173476

... More
Supply of PVC insulated wire copper conductor 16/02 mm to ATC IS:694 to RDSO spec no IRS S76/89. Each coil of 100 mts length. To be procured from RDSO approved firms. Inspection by consignee. (Unit read as Coils)

4800

1338

6422400

... More
Supply of indoor Signaling cable 60 core x 0.6mm as per IRS S76/89 amend no 3 or latest. Inspection by RDSO.

15

158264

2373960

... More
Supply of terminal block 6 Way PBT 25 mm as per RDSO Drg No SA 23756/Alt 3 & IRS S 75/91 & IRS S 23 with amendment 2 or latest. Inspection by consignee.

1500

479

718500

... More
Supply of terminal block 1 Way PBT 60mm as per RDSO Drg No SA 23745/Alt 5 & IRS S 75/91 & IRS S 23 with latest amendment (Inspection by RDSO)

467

102

47634

... More
Supply of WAGO/ELMEX/PHOENIX terminal as per RDSO spec 189/2004. Inspection by consignee.

2700

816

2203200

... More
Supply of Non-deteriorating type of fuse holders and fuse links-electric fuse for Railway signaling voltage 240 AC/DC as per RDSO spec IRS S.78/92 (IRS-S-78/97 Tentative) IS: 13703 (part 2 sec2):1993 suitable for E1 fuse 20 Amps SC-20 Holder Safe clip/ knife edge type size E1 (R-SS) amp. Inspection by consignee.

-

-

373950

... More
Supply of Steel Apparatus case 'large Size' as per Drg. No - CON/SK/1/1/86 and Spec.No. IRS:S- 10/78 (adv) with latest amnd. with "E" type lock and key of ward No-32 with handle. Inspection by RITES.

230

42507

9776610

... More
Supply of relay fixing frame for Full location box, the frame should be made out MS angle of 25mm X 25mm X 3mm and approximate size of 940mm X 150mm with suitable holes to fix the same in the box. Inspection by consignee.

390

992

386880

... More
Supply and fixing of 20 mm thick teak wood planks for keeping equipments in full box after applying two coats of wood primer. The approximate size of pank is 940 mm x 20mm x 300 mm. Inspection by consignee. (Unit - per Plank)

390

854

333060

... More
Supply of hylam sheet, resin bonded, 6mm thick, grade P3, to IS specification IS:2036 of 1974 or latest and size 2400mm X 1200mm of color approved by site in-charge. Inspection by consignee.

45

8095

364275

... More
Supply of PVC insulated wire multi-strand per conductor 10 Sq.mm flexible. Spec IRS S76/89. Amendment No 2 or latest. Each coil of 100 mts length To be procured from RDSO approved firms (SIZE 140/03 mm). Inspection by RDSO. (Unit read as Coils)

1868

15766

29450888

... More
Supply of lightening and surge arrestors of class B&C suitable for single phase supply in TT network as per amendment 5 of RDSO spec.No.RDSO/SPN/165/2004 or or Latest and as recommended by RDSO letter No.STS /E/IPS/GENL dtd: 27.01.06 (Amendment 5). Inspection by RITES.

150

25184

3777600

... More
Supply of E type locks of different ward as per requirement with key per E-type lock to Drg No.S A.3376/M/Latest and RDSO spec no lRS. S.30/64. Inspection by consignee.

195

940

183300

... More
Supply of Universal lock with one key for every 10 locks. Inspection by consignee.

195

101

19695

... More
Supply of 19 42 U covered racks complete with all fittings and accessories. Inspection by consignee.

68

76848

5225664

... More
Supply of Thermo shrinkable jointing kit as per Spec. No. IRS TC. 77/2012(Rev 3) Amd 3 for all types joints suitable for 6 Quad Jelly filled UG cable. Inspection by RDSO.

18

6143

110574

... More
Supply of DWC pipe of 63 mm outer dia/50 mm inner dia in length of 6 Mtr with coupler. to IS specification No.14930 Part-II. The IS spec shall be marked on the pipe. Inspection by consignee.

1446

708

1023768

... More
Supply of Digital Earth Tester 0.01 to 99 Ohms.In 5 ranges 4 terminals type with all facilities WACO make or similar. Inspection by consignee.

3

24327

72981

... More
Supply of AC/DC Digital clamp meter Fluke-376 or similar. Inspection by consignee.

3

83661

250983

... More
Supply of Insulation resistance tester 500V DC 500 Mega Ohms hand generator type metal body to Spec. no. IS:2992 make WACO. Inspection by consignee.

2

17857

35714

... More
Supply of Insulation resistance tester 100 V DC 500 Mega Ohms hand generator type metal body to Spec. no. IS:2992 make WACO. Inspection by consignee.

2

13789

27578

... More
Supply of portable Cable fault locator (Metallic Time Domain Reflectometer) suitable in RE/Non RE Railway territory with all accessories for locating faults such as loop and break in various twisted pair cable such as 34 underground telecom quad cables, signalling cables , telephone jelly filled cables, LAN etc. Instrument to be supplied with protective nylon carrying bag and operators manual. make/model:Radio detection riser bond, Model 3300 or make/model;RC-RT (TDR) MRPC/Rail 2018 or latest equivalent along with other OEM or OEM authorised with documentary proof. Inspection by consignee.

3

382612

1147836

... More
Supply of High Power, Electronic Cable Route Tracer/ Pipe and Cable locating kit with 36 user configurable Active multi frequency options including 200Hz, 512Hz, 797Hz, 815Hz, 8kHz, 33kHz, 65kHz, 82kHz, 200kHz upto 476.2kHz, passive detection @ 50Hz for power cables, Radio Mode for locating metallic utilities 35 whether energised or not, Current measurement, LCD Display with left-right arrow function , Modes: peak, peak with arrow, pin point peak and null modes, Compass function; Depth measurement. Supply includes locating receiver, Transmitter (Max power : 12Watt) with Li-ion Rechargeable Batteries for both Transmitter & Receiver,Battery charger, Induction Signal Clamp 4'', supplied in a carry bag. Similar to 3M-Dynate/Radio detection / Stanlay Pathfinder LOC10. Inspection by consignee.

3

379188

1137564

... More
Supply of Reclining Chair for Camping to be used in field during inspection and SAT testing of Dechathlon make or similar. Inspection by consignee.

59

5258

310222

... More
Supply of thick Kodak photo paper with lamination of various sizes with different lettering and lauguages in required size as per the instructions of site incharge. Proportionate payment to the size of boards. Inspection by consignee.

59

6748

398132

... More
Supply & installation of multifunction Printer for Office use for printing tag-data, RFID plans etc. HP Laserjet MFP 138 fnw or similar. Inspection by consignee.

3

183330

549990

... More
Supply & installation of Multi function wide format Plotter Printer. Inspection by consignee.

1

624220

624220

... More
Supply of A3 Printer for printing NMS fault and exception reports similar to Epson L 1300 model or latest. Inspection by consignee.

2

44517

89034

... More
Supply and installation of 64 input digital stack card for Data Logger. Inspection by RDSO.

46

21225

976350

... More
Supply and installation of Digital Data Logger mother board to upgrade from 512 to 1024/2560 or higher digital inputs. Inspection by RDSO.

23

58958

1356034

... More
Supply of Datalogger complete to spec No- IRS:S:99/2006 AMD. 3 or latest with configuration of 512 digital inputs and 64Analog inputs with self power supply system, protocol converters as required etc with networking facilities. Inspection of Data Logger by RDSO & balance item by representative of Railway.

3

579524

1738572

... More
Supply of Program Maintenance Console for system monitoring. Inspection by consignee.

2

39000

78000

... More
Alteration of database, faults, simulations in Data loggers and all connected places (like HQ, FEP, STATION, etc)

23

18370

422510

... More
Supply, Installation, Testing & commissioning of Mini SMPS based Integrated power supply 1 system(IPS) confirming to RDSO specification No. RDSO/SPN/165/2012[Ver.3.0] or latest with latest Amendmend as on date of opening of the Tender and as per East Coast Railway Drawing No. CSTE/ECOR/TYP/2/11/AIt2 Including supply of additional spares as per approved drawing Inspection by RDSO.

15

1221300

18319500

... More
Supply, Installation andcommissioning of SMPS BASED INTEGRATED POWER SUPPLY SYSTEM (IPS) CONFIRMING TO RDSO SPECIFICATION NO. RDSO/SPN/165/2023 (VER 4.0) WITH LATEST 2 AMENDMENT AS ON THE DATE OF OPENING OF THE TENDER AS PER E.CO.RLY DRAWING No.CSTE/ECOR/TYP/4/11/ALT2 INCLUDING SUPPLY OF ADDITIONAL SPARES AS PER APPROVED DRAWING. THE MANDATORY TOOLS AND SPARES TO BE SUPPLIED AS PER RDSO SPECIFICATION.Specifications as mentioned.Inspection by RDSO. Note: This isinclusive of supply of Battery set asper load requirement and initialcharging & discharging.

2

1769327

3538654



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.