Andhra Pradesh State Financial Corporation Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Andhra Pradesh State Financial Corporation - APSFC Tender

Opening Date13 Aug 2020
Closing Date24 Aug 2020
Tender Amount₹ 18,86,917 
This is an estimated amount, exact amount may vary.
Notes
Download

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply,Installation, testing and commissioning of 4way Cassette Type Indoor Units with Panel & Wireless Remote including Refnet joints / Distribution joint kits:Makes: Daikin/Thoshiba/Mitsubishi/O General/LG/Voltas/Blue star/Hitachi/Carrier/Samsung:(Latest model) - 2.08 TR

4

-

36695

... More
Supply,Installation, testing and commissioning of 4way Cassette Type Indoor Units with Panel & Wireless Remote including Refnet joints / Distribution joint kits:Makes: Daikin/Thoshiba/Mitsubishi/O General/LG/Voltas/Blue star/Hitachi/Carrier/Samsung:(Latest model) - 1.65 TR

1

-

36307

... More
Supply,Installation, testing and commissioning of 4way Cassette Type Indoor Units with Panel & Wireless Remote including Refnet joints / Distribution joint kits:Makes: Daikin/Thoshiba/Mitsubishi/O General/LG/Voltas/Blue star/Hitachi/Carrier/Samsung :(Latest model) - 1.32 TR

1

-

36000

... More
Supply,Installation, testing and commissioning of Wall Mounted Type Indoor Units with Wireless Remote including Refnet joints / Distribution joint kits:Makes: Daikin/Thoshiba/Mitsubishi/O General/LG/Voltas/Blue star/Hitachi/Carrier/Samsung :(Latest model)- 1.05 TR

2

-

35000

... More
Supply,Installation, testing and commissioning of Wall Mounted Type Indoor Units with Wireless Remote including Refnet joints / Distribution joint kits:Makes: Daikin/Thoshiba/Mitsubishi/O General/LG/Voltas/Blue star/Hitachi/Carrier/Samsung :(Latest model)- 0.83 TR

3

-

34500

... More
Supply , Installation,Testing and Commissioning of suitable Refnet joints / Distribution joint kits to take care of connectivity and circuiting as per respective VRV/VRF system manufacturers specification(additionally required other than those included in Indoor Units item) :All sizes

2

-

4740

... More
Supply,installation of suction & liquid copper Refrigerant piping including brazing as per relevent BIS standards IS 10773-1995 with proper supports/hangers from ceiling/wall as required at site & approved by consultant/ recommended by VRV/VRF manufacturer, duly insulated with closed cell elastomeric nitrile insulation of 13mm thick for pipes above 1" and 9 mm thick for pipes below 1" as per manufacturers standards and specifications appoved by the Dept. This includes Pressure testing of the entrire system with Nitrogen and vaccumizing the entire system before charging required additional refrigerent.:Suction line 38.10mm dia + liquid line 19.05 mm

15

-

1430

... More
Supply,installation of suction & liquid copper Refrigerant piping including brazing as per relevent BIS standards IS 10773-1995 with proper supports/hangers from ceiling/wall as required at site & approved by consultant/ recommended by VRV/VRF manufacturer, duly insulated with closed cell elastomeric nitrile insulation of 13mm thick for pipes above 1" and 9 mm thick for pipes below 1" as per manufacturers standards and specifications appoved by the Dept. This includes Pressure testing of the entrire system with Nitrogen and vaccumizing the entire system before charging required additional refrigerent.:Suction line 34.10mm dia + liquid line 19.05 mm

25

-

1380

... More
Supply,installation of suction & liquid copper Refrigerant piping including brazing as per relevent BIS standards IS 10773-1995 with proper supports/hangers from ceiling/wall as required at site & approved by consultant/ recommended by VRV/VRF manufacturer, duly insulated with closed cell elastomeric nitrile insulation of 13mm thick for pipes above 1" and 9 mm thick for pipes below 1" as per manufacturers standards and specifications appoved by the Dept. This includes Pressure testing of the entrire system with Nitrogen and vaccumizing the entire system before charging required additional refrigerent.:Suction line 28.58mm dia + liquid line 19.05 mm

48

-

1270

... More
Supply,installation of suction & liquid copper Refrigerant piping including brazing as per relevent BIS standards IS 10773-1995 with proper supports/hangers from ceiling/wall as required at site & approved by consultant/ recommended by VRV/VRF manufacturer, duly insulated with closed cell elastomeric nitrile insulation of 13mm thick for pipes above 1" and 9 mm thick for pipes below 1" as per manufacturers standards and specifications appoved by the Dept. This includes Pressure testing of the entrire system with Nitrogen and vaccumizing the entire system before charging required additional refrigerent.:Suction line 28.58mm dia + liquid line 15.88 mm

15

-

1130

... More
Supply,installation of suction & liquid copper Refrigerant piping including brazing as per relevent BIS standards IS 10773-1995 with proper supports/hangers from ceiling/wall as required at site & approved by consultant/ recommended by VRV/VRF manufacturer, duly insulated with closed cell elastomeric nitrile insulation of 13mm thick for pipes above 1" and 9 mm thick for pipes below 1" as per manufacturers standards and specifications appoved by the Dept. This includes Pressure testing of the entrire system with Nitrogen and vaccumizing the entire system before charging required additional refrigerent.:Suction line 28.58mm dia + liquid line 12.70 mm

10

-

1070

... More
Supply,installation of suction & liquid copper Refrigerant piping including brazing as per relevent BIS standards IS 10773-1995 with proper supports/hangers from ceiling/wall as required at site & approved by consultant/ recommended by VRV/VRF manufacturer, duly insulated with closed cell elastomeric nitrile insulation of 13mm thick for pipes above 1" and 9 mm thick for pipes below 1" as per manufacturers standards and specifications appoved by the Dept. This includes Pressure testing of the entrire system with Nitrogen and vaccumizing the entire system before charging required additional refrigerent.:Suction line 22.22mm dia + liquid line 12.70 mm

10

-

890

... More
Supply,installation of suction & liquid copper Refrigerant piping including brazing as per relevent BIS standards IS 10773-1995 with proper supports/hangers from ceiling/wall as required at site & approved by consultant/ recommended by VRV/VRF manufacturer, duly insulated with closed cell elastomeric nitrile insulation of 13mm thick for pipes above 1" and 9 mm thick for pipes below 1" as per manufacturers standards and specifications appoved by the Dept. This includes Pressure testing of the entrire system with Nitrogen and vaccumizing the entire system before charging required additional refrigerent.:Suction line 19.05mm dia + liquid line 12.70 mm

10

-

860

... More
Supply,installation of suction & liquid copper Refrigerant piping including brazing as per relevent BIS standards IS 10773-1995 with proper supports/hangers from ceiling/wall as required at site & approved by consultant/ recommended by VRV/VRF manufacturer, duly insulated with closed cell elastomeric nitrile insulation of 13mm thick for pipes above 1" and 9 mm thick for pipes below 1" as per manufacturers standards and specifications appoved by the Dept. This includes Pressure testing of the entrire system with Nitrogen and vaccumizing the entire system before charging required additional refrigerent.:Suction line 19.05mm dia + liquid line 9.52 mm

10

-

850

... More
Supply,installation of suction & liquid copper Refrigerant piping including brazing as per relevent BIS standards IS 10773-1995 with proper supports/hangers from ceiling/wall as required at site & approved by consultant/ recommended by VRV/VRF manufacturer, duly insulated with closed cell elastomeric nitrile insulation of 13mm thick for pipes above 1" and 9 mm thick for pipes below 1" as per manufacturers standards and specifications appoved by the Dept. This includes Pressure testing of the entrire system with Nitrogen and vaccumizing the entire system before charging required additional refrigerent.:Suction line 15.88mm dia + liquid line 9.52 mm

70

-

760

... More
Supply,installation of suction & liquid copper Refrigerant piping including brazing as per relevent BIS standards IS 10773-1995 with proper supports/hangers from ceiling/wall as required at site & approved by consultant/ recommended by VRV/VRF manufacturer, duly insulated with closed cell elastomeric nitrile insulation of 13mm thick for pipes above 1" and 9 mm thick for pipes below 1" as per manufacturers standards and specifications appoved by the Dept. This includes Pressure testing of the entrire system with Nitrogen and vaccumizing the entire system before charging required additional refrigerent.:Suction line 12.70mm dia + liquid line 6.35 mm

5

-

640

... More
Supply & initial Charge of additional refrigerant gas - R 410 A for all outdoor units as per the requirment assesed by the Refigeration Engineer of respective VRV/VRF System Manufacturers (Payment shall be made on actual gas charged)

30

-

760

... More
Supply,installation of Drain Piping:Rigid CPVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation. 25 mm dia

50

-

90

... More
Supply,installation of Drain Piping:Rigid CPVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation. 32 mm dia

110

-

105

... More
Supply,installation of Drain Piping:Rigid CPVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation. 45 mm dia

80

-

130

... More
Supply & fixing including terminations control cum transmission wiring of 2 core x 1.5 sqmm copper between indoor and out door unit.

550

-

95



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.