Andhra Pradesh Industrial Infrastructure Corporation Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Andhra Pradesh Industrial Infrastructure Corporation - APIIC Tender
Security and Emergency Services
Opening Date19 Dec 2024
Closing Date3 Jan 2025
Tender Amount₹ 45,73,346
Costs
EMD
₹ 46,000Document Cost
Refer DocumentsTender Fee
₹ 2,360
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
775425Tender No
11/CE(N)/APIIC/2024-25, Dated: 18.12.2024Tender Authority
Andhra Pradesh Industrial Infrastructure Corporation ViewPurchaser Address
-Website
http://https://www.apiic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Operation & preventive maintenance, routine checking of HVAC system in Millennium Tower comprising of all the machineries & equipment installed in the HVAC Plant Room, including Water Cooled Chillers (3 Nos.), Cooling Towers (2 Nos.), Primary (3 Nos.) & Secondary Pumps (3 Nos.), Condenser pumps (3 Nos.), all HVAC panels, VFD, Air Handling Units (8 Nos.), Treated Fresh Air Units (8 Nos.), Ventilation fans etc,. including piping network for chilled water circulation along with their accessories insulation such as bends, tees, reducer flanges, valves, strainers outlets, leakages in MS pipes etc.,and also the agency shall provide daily services such as checking bearings of all motors and motor driven equipment’s for vibration, excessive sound and heating of HVAC System are to be covered through out the period of contract for 24 x 7 for 3 shifts by one Skilled Technician per shift including all T & P as directed by the Engineer-In-Charge.
12
80780
969360
... More
Operation & preventive maintenance, routine checking of Fire Hydrant and Sprinkler systems comprising of Main fire pumps, Jockey Pumps M.V panel of auto/manual operation including battery Charger for diesel engine, Siren along with internal and external electrical systems, pump room, Power house and aslo Microprocessor based Fire Alarm System & detection control panels, battery back system, all types of smoke detectors, response indicators, manual call points, control modules, circuit isolators, monitor module, hooters, detector with sounder base including associated wiring work up to main fire control panel installed at various locations of Building, DDC controller, lifts, fire damper, damper Relay module and controller if found faulty then need to be replaced on an immediate basis, are to be covered through out the period of contract for 24 x 7 x 365 for 2 shifts by one Skilled Technician per shift including all T & P and man power for attending break down calls/repairing/testing/ replacement of all defective components of fire alarm control panel, servicing of the installed
12
53854
646248
... More
equipments, testing the serviceability of all the zones of all fire control panels by simulating the fire situation i.e. by means of smoke etc., once quarterly in the presence of M/s. Conduent representative. Few detectors/MCPs are to be selected randomly for testing and preparation of Joint inspection report as per standard format and submitting the same to the Engineer-In-Charge.
-
-
-
... More
Supply, fixing, testing and commissioning of 350 mm dia Butterfly valve of PN-16 rating with Cast Iron body, SGI (Nylon Coating) disc, EPDM Seat, SS 431 Shaft with Gear operated, wafer type including transportation charges to work site and labour charges for lowering and keeping in position, incidental & operational charges etc., complete for finished item of work for emergency replacement incase of failure of existing valves of cooling towers 1 and 2. [Makes: Advance/L&T/Audco/ Honeywell]
4
40443
161772
... More
Supply, Delivery and fixing of 350 mm Dia D.I Double Flanged Swing Check type Reflux valves (Non Return Valves) (PN 1.6 (MPa) conforming to IS- 5312 (Pts-1&2) (with amendments up to date, if any) having Body, Cover, Door, Bearing holder with D.I; Hinge pin, Door pin, Door suspension pin with Stainless Steel (IS 6603); Body seat ring , Door face ring, Bearing bushes, Plugs for hinge pin with Leaded Tin Bronze ( IS 318 ); Bolts, Nuts with Carbon steel; Gaskets with Rubber; Hinges with Cast steel; including conveyance to work site, labour charges for lowering and keeping in position, incidental & operational charges etc., complete for finished item of work to replace the defective ones pertaining to condenser pipe line if required. [Makes: Advance/L&T/Audco/Honeywell]
1
70950
70950
... More
Servicing of pump and motor including Mechanical seal, bearings, housing gasket with sealant for Xylem make pumps for the following models including all incidental charges.
-
-
-
... More
Primary Chilled water pump of Xylem Make - Model No: 1510 6G, 1450 R.P.M, 22 kW
3
30000
90000
... More
Secondary Chilled water pump of Xylem Make - Model No: 1510, 6BC,1450 R.P.M, 15 kW
3
28000
84000
... More
Supply of 95 A (AC3), 3 Pole Power Contactor conforming to IS/IEC 60947-4-1 and IEC 60947-4-1 including cost, conveyance charges to site etc., complete to replace the defective ones in the starter panel pertaining to 3-Phase, 415 V, 50 Hz, 1455 RPM, 20 HP Induction motor of condenser water pump. [Makes : L&T (Cat. no CS94136)/Seimens/ Schneider]
8
16186
129488
... More
Manufacture, Supply, & Delivery of 160 mm Outer dia HDPE Pipe (6.0 kg/Sq.cm) of PE - 100 Grade, conforming to IS 4984-2016 for draining out water from cooling tower including transportation to anywhere in A.P etc., complete but excluding fittings and all taxes.
40
813
32520
... More
Manufacture, Supply, & Delivery of the following HDPE (PE –100 Grade) fittings conforming to IS 4984 - 2016 including transportation to anywhere in A.P.
-
-
-
... More
Cost of PIPE ENDS LONG NECK
10
669
6690
... More
Cost of MS FLANGES
10
422
4220
... More
Cost of END CAPS
1
399
399
... More
Cost of TEES
2
1937
3874
... More
Cost of BENDS
1
1610
1610
... More
Cost of Bolt/Nut/Washer (hot dipped galvanized)
10
1659
16590
... More
Supply and fixing of 415 V, 50 Hz, 5.5 kW/7.5HP, 710 RPM, IP 65, 3-Phase induction motor, IE-2 efficiency class, and insulation class F etc., for cooling tower on terrace including cost, transportation and labour charges for fixing, testing to full load, commissioning charges with all incidental expenses etc., in place of existing unserviceable motor and buyback of the same in "as is where is" condition. [Makes : ABB/NewIndia (Navyug Electric Motors and Pumps]
2
42229
84458
... More
Supply and fixing of Cooling Tower fills of 2 ft./1ft., in place of defective ones including cost, conveyance and labour charges etc., complete.
450
360
162000
... More
Supply and fixing of Float valve in place of the defective ones, including cost, conveyance and labour charges etc., complete.
2
5249
10498
... More
Supply and fixing of Cooling Tower Nozzle in place of the defective ones, including cost, conveyance charges and labour charges etc., complete.
55
1356
74580
... More
FRP coating to arrest water leakages on MS pipe lines with FRP Materials (Resin, Mat, Catalyst, Accelerator, Brush etc.,) including cost of all materials, transportation, and labour charges with all incidental expenses etc., complete.
16
500
8000
... More
Supply of 18 A (AC3), 3 Pole Power Contactor conforming to IS/IEC 60947-4-1 & IEC 60947-4-1 including cost, conveyance charges etc., complete to replace the defective ones in the starter panel pertaining to 3 -Phase, 415 V, 50 Hz, 1455 R.P.M, 7.5 HP Induction motor of cooling tower. [Makes: L&T (CS94100)/Seimens/Schneider]
6
1161
6966
... More
Supply of 100 A, 415 V Bakelite Open Type 6 Way Connector code AI - 10003 including transportation to site etc., complete to replace the defective ones and for immediate replacement incase of failure.
6
2050
12300
... More
Supply of 70 A (AC3), 3 Pole Power Contactor conforming to IS/IEC 60947-4-1 & IEC 60947-4-1 including cost, conveyance charges to site etc., complete to replace the defective ones and for immediate replacement incase of failure. [Makes : L&T (CS97076)/Seimens/ Schneider]
6
8559
51354
... More
Supply of Front Mounting Add-on aux. Contact Block (2 NO + 2 NC) including transportation charges to site etc., complete to replace the defective ones and for immediate replacement incase of failure. [Makes: L&T (Cat No: CS94114)/Seimens/Schneider]
6
504
3024
... More
Supply of 6W LED Slim Panel Round/Square suitable for Recessed/Surface mounting made of die-cast Aluminum body with powder coating, Acrylic diffuser with driver as per IS:15885 (Part 2/ Sec 13): 2012, operating voltage range of 150 to 265 Volts AC, P.F 0.9, Surge protection: 2 kV, THD10%, with high power LEDs, having system efficacy of 120 lumens/watt, CCT: 5700 K, minimum CRI70, etc., complete with earth connection and warrenty not less than two years to replace the dysfunctional ones in existing lifts including transportation charges to site with all incidental expenses etc., complete. [Makes: Havells/GE-Venture/Wipro/ Crompton/Signify]
30
449
13470
... More
Supply of 6-32A, 10 kA- SP MCB (C/D Curve) ISI Mark to replace the defective ones in control panels including transportation charges etc., complete. [Makes:Legrand-DX3/Schneider-A9/Hager-h3/Siemens-5SX4]
30
259
7770
... More
Cost for cooling water treatment program for cooling tower at site including cost of chemicals, transportation and labour charges with all incidental charges etc., complete.
12
17000
204000
... More
Supply of 600mm (Width) x 75mm (Depth) x 2.0 mm (Thickness) size of Hot Dipped Galvanized Iron ladder type cable trays with rungs at span of 250 mm including horizontal and vertical bends, reducers tees, cross members and other accessories as required and duly suspended from the ceiling/wall with suspenders and etc., complete to replace the rusted onces on terrace for panel cables of cooling tower.
30
1041
31230
... More
Supply of 24 V, 40 A Battery Charger conforming to the technical specifications such as input Voltage 170V to 270V operating range, Operating Temperature -20 to 85 Deg C, Low Standby Power Consumption and High Efficiency, High Input Output isolation 3000 V AC and High surge immunity, Input over and under voltage protections, Output short circuit, over-load, over-voltage protection, charging battery from zero volts, drawing zero current from the battery, Three Stage Charging etc., complete to replace the defective ones for existing 1500 kVA Diesel generator including transportation charges to site with all incidental expenses etc., complete. [Make : NHP Power Systems LLP]
1
9800
9800
... More
Replacing the existing unserviceable Deep Groove Ball Bearing pertaining to 3 -Phase, 415 V, 50 Hz, 710 RPM, 7.5 HP Induction electric motor of Cooling Tower with new ones with due alignment of the shaft and tested, and special T & P [Makes : NBC/SKF]
4
1851
7406.22
... More
No. of BOQ items: 25 (Twenty Five) only
-
-
4573345.22
... More
(Rupees Forty Five Lakhs Seventy Three Thousand Three Hundred and Forty Six Only)
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements