Airports Authority Of India Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Airports Authority Of India - AAI Tender
Electrical Generators And Transformers
Electrical and Electronics
GEM
Opening Date8 May 2024
Closing Date29 May 2024
Tender Amount₹ 1,96,12,848
Costs
EMD
₹ 3,92,257Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
GEM/2024/B/4904762Bid Award Id
ViewTender No
GEM/2024/B/4904762Tender Authority
Airports Authority Of India ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
merged01052024_2024-05-01-16-35-52_c8541a23863e9a595b4123e1023767b3.pdf
gem_boq_01052024_2024-05-01-16-35-52_1e77e0f6dc504232cb05c8db5bb11ffe.csv
BOQ Items
... More
Supply of Silica gel , Supply of Silica gel crystals for transformer breathers etc. as and when required.
60
-
-
... More
Supply of transformer oil , Supply of transformer oil with test report for topping up the transformer i/c transportation as and when required.
800
-
-
... More
Testing and calibration of 33 KV HT VCB Over current cum earth fault relay , Testing,Servicing and calibration of the following relays including checking and rectifying the tripping circuit for HT 33KV VCB incoming / outgoing panels etc., complete as required.
(a) Over current relay cum earth fault relay.
8
-
-
... More
Testing and calibration of 33 KV HT VCB master trip relay , Testing, Servicing and calibration of the following relays including checking and rectifying the tripping circuit for HT 33KV VCB incoming / outgoing panels etc., complete as required.
(b) 33 KV HT VCB panel master trip relay testing and calibration
14
-
-
... More
Testing and calibration of 33 KV HT VCB panel trip supervision relay , Testing,Servicing and calibration of the following relays including checking and rectifying the tripping circuit for HT 33KV VCB incoming / outgoing panels etc., complete as required.
(c) 33 KV HT VCB panel trip supervision relay testing and calibration.
8
-
-
... More
Testing and calibration of 33 KV HT VCB panel timer relay , Testing,Servicing and calibration of the following relays including checking and rectifying the tripping circuit for HT 33KV VCB incoming / outgoing panels etc., complete as required.
(d) 33 KV HT VCB panel timer relay testing and calibration for Incomer Panel
2
-
-
... More
Testing and calibration of 33 KV HT VCB panel under voltage relay , Testing,Servicing and calibration of the following relays including and checking and rectifying the tripping circuit for HT 33KV VCB incoming / outgoing panels etc., complete as required.
(e) 33 KV HT VCB panel under voltage relay testing and calibration for Incomer Panel
2
-
-
... More
Testing and calibration of 33 KV HT VCB panel supervision Auxiliary relay for Trip and Alarm , Testing,Servicing and calibration of the following relays including and checking and rectifying the tripping circuit for HT 33KV VCB incoming / outgoing panels etc., complete as required.
(f) 33 KV HT VCB panel supervision Auxiliary relay for Trip and Alarm, testing and calibration for Transformers (2 relays per Transformer VCB)
24
-
-
... More
Testing and calibration of 33 KV HT VCB 7 SR Numerical relay , Testing,Servicing and calibration of the following relays including and checking and rectifying the tripping circuit for HT 33KV VCB incoming / outgoing panels etc., complete as required.
(g) 33 KV HT VCB 7 SR Numerical relay
6
-
-
... More
Half-yearly maintenance and Servicing of 33KV, 1250A VCB , Half-yearly maintenance and Servicing of 33KV, 1250A VCB including complete servicing and cleaning of breaker mechanism parts, checking all electrical and mechanical components, checking and servicing of draw-out mechanism etc, complete as required and six months service warranty, breakdown calls should be attend within 24 hours. (Maintenance shall be carried out through OEM / authorized dealer).
(a) 33KV / 1250A Incomer - 2 Nos.
(b) 33KV / 1250A Out-going - 5 Nos.
28
-
-
... More
Half-yearly Maintenance and Servicing of 415V, 4 Pole,2500Amp ACB , Half-yearly Maintenance and Servicing of 415V, 4 Pole ACB of following rating including complete servicing and cleaning of breaker mechanism parts, checking all electrical and mechanical components ,checking and servicing of draw-out mechanism including removal of worn-out electrical and mechanical parts, replacement works etc, complete as required and six months service warranty and break down calls should be attended within 24 hours. Spares will be provided by AAI. (Maintenance shall be carried out through OEM / OEM authorized dealer).
(a) 2500A / 4Pole ACB for Transformers out going and Bus Couplers-7 Nos
28
-
-
... More
Half Yearly testing and calibration of relays associated with ACBs in BOQ No. 14 , Half Yearly testing and calibration of relays associated with ACBs in BOQ No. 14 including submitting test reports etc., complete as required. (Testing and Calibration shall be carried out through OEM / OEM authorized dealer).
28
-
-
... More
Half-yearly Maintenance and Servicing of 415V, 4 Pole,1250 Amp ACB , Half-yearly Maintenance and Servicing of 415V, 4 Pole ACB of following rating including complete servicing and cleaning of breaker mechanism parts, checking all electrical and mechanical components ,checking and servicing of draw-out mechanism including removal of worn-out electrical and mechanical parts, replacement works etc, complete as required and six months service warranty and break down calls should be attended within 24 hours. Spares will be provided by AAI. (Maintenance shall be carried out through OEM / OEM authorized dealer).
(b) 1250A / 4Pole ACB Out-going - 28 Nos.
112
-
-
... More
Half Yearly testing and calibration of relays associated with ACBs in BOQ No. 16 , Half Yearly testing and calibration of relays associated with ACBs in BOQ No. 16 including submitting test reports etc., complete as required. (Testing and Calibration shall be carried out through OEM / OEM authorized dealer).
112
-
-
... More
Half-yearly Maintenance and Servicing of 415V, 4 Pole,1000 Amp ACB , Half-yearly Maintenance and Servicing of 415V, 4 Pole ACB of following rating including complete servicing and cleaning of breaker mechanism parts, checking all electrical and mechanical components ,checking and servicing of draw-out mechanism including removal of worn-out electrical and mechanical parts, replacement works,relay testing etc, complete as required and six months service warranty and break down calls should be attended within 24 hours. . spares will be provided by AAI. (Maintenance shall be carried out through OEM / OEM authorized dealer).
(C) 1000A / 4Pole ACB Out-going - 04 Nos
16
-
-
... More
Half Yearly testing and calibration of relays associated with ACBs in BOQ No. 18 , Half Yearly testing and calibration of relays associated with ACBs in BOQ No. 18 including submitting test reports etc., complete as required. (Testing and Calibration shall be carried out through OEM / OEM authorized dealer).
16
-
-
... More
Half-yearly Maintenance and Servicing of 415V, 4 Pole,800Amp ACB , Half-yearly Maintenance and Servicing of 415V, 4 Pole ACB of following rating including complete servicing and cleaning of breaker mechanism parts, checking all electrical and mechanical components ,checking and servicing of draw-out mechanism including removal of worn-out electrical and mechanical parts, replacement works,relay testing etc, complete as required and six months service warranty and break down calls should be attended within 24 hours spares will be provided by AAI. (Maintenance shall be carried out through OEM / OEM authorized dealer).
(d) 800A / 4Pole ACB Out-going - 17 Nos.
68
-
-
... More
Half Yearly testing and calibration of relays associated with ACBs in BOQ No. 20 , Half Yearly testing and calibration of relays associated with ACBs in BOQ No. 20 including submitting test reports etc., complete as required. (Testing and Calibration shall be carried out through OEM / OEM authorized dealer).
68
-
-
... More
Supply of Power Pack with Battery back charger , Supply of Power Pack with Battery back charger suitable to input voltage of 230V 50Hz and output voltage 24V DC, to operate on continuous load of 100w, and momentary load of 450w for 240msec , bsttery back up time of 10min , details of battery are 12V DC, 7AH (Similar to ALAN , Model APP230024-10)
1
-
-
... More
SITC ACB Relay , Supply, Installation, Testing and Commissioning of L and T make relay Model - MATRIX UW-MTX 3.5EC release suitable for L and T make U-Power Omega ACB (Make - L and T).
3
-
-
... More
Transportation of HSD oil , Transportation of HSD oil from Petrol bunk to Airport power house Approx. quantity of oil to be transported upto 1000 ltrs. Approx. distance from petrol bunk is 4 Km. Excluding loading and unloading.
100
-
-
... More
Painting of LT panels and Feeder pillars and Pipe line , Painting of LT panels / Feeder pillars and Pipe line with one coat metal primer on rusted surface and two coats approved synthetic enamel paint , lettering etc., as required upto the satisfaction of the Engineer-in-charge as and when required.
200
-
-
... More
Painting of street light poles , Painting of street light poles with one coat of metal primer on rusted surface and two coats of approved aluminum paint i/c dismantling, re-fixing of fittings and scraping the surface as required to the satisfaction of the Engineer-in-charge as and when required.
Pole height 11mtrs. approximately.
200
-
-
... More
Pollution test and Stack monitoring and Noise level , Pollution test /Stack monitoring and Noise level monitoring of 750KVA DG-Sets with suitable kit including Conducting SPM(Suspended particles matter), SO2 (Sulphur dioxide), NOx (Oxides of Nitrogen) tests and submision of test reports etc. as and when required.
10
-
-
... More
Operation and Maintenance of STP , Operation and Maintenance of Sewage Treatment Plant System by carrying out preventive maintenance, attending to the complaints, maintaining records by providing qualified manpower, tools, cleaning materials etc., round the clock including sundays and holidays in three shifts as per enclosed Special conditions of contract and particular specifications and as per the instructions of the Engineer-in-Charge or his authorized representative from time to time complete as required.
24
-
-
... More
Supply of Chlorine , Supply of following Chemicals for day to day operation of Sewage Treatment Plant.
a) Chlorine
2880
-
-
... More
Supply of Urea , Supply of following Chemicals for day to day operation of Sewage Treatment Plant.
b) Urea
6570
-
-
... More
Supply of DAP , Supply of following Chemicals for day to day operation of Sewage Treatment Plant.
c) DAP
1826
-
-
... More
Supply of Nutrients , Supply of following Chemicals for day to day operation of Sewage Treatment Plant.
d) Nutrients
3650
-
-
... More
Testing of sewage inlet and tretaed water , Carrying out of following tests of sewage Inlet and treated water sample in reputed testing lab and submitting of bimonthly report including to & fro transportation to the site., etc complete job as required.
(a) PH (b) TDS (c) TSS (d) BOD (e) COD (f) Chlorides (g) Sulphates
24
-
-
... More
Replacement od sand stone aggregate , Replacement of sand and stone aggregate (20 mm) in the filter bed once in year by providing river sand stone aggregate and disposing of digged out sand / agreegate within a lead of 50 metre as direction of Engineer-In-Charge.
1
-
-
... More
Rewinding of 7.5KW, 415V, 3 Ph induction motor , Rewinding of 7.5KW, 415V, 3 Ph induction motor by dismantling, cutting of burnt out wire rewinding with new winding with suitable guage enamelled copper wire, varnishing, baking, re-assembling of set including to and fro transportation to the site etc., complete job as on when required.
4
-
-
... More
Repair and Overhauling of 7.5 KW Twin lobe Blower , Complete repair & overhauling of Twin lobe blower of capacity 230 cfm,6 psi suitable to work on 7.5KW, 415V, 3 Ph induction motor by dismantling, replacement of neccessary spares such as , shaft, blades, bushes,..etc if required including lubricating on the parts wherever required and re-assembling of set including to and fro transportation to the site,dremoving & Refixing, testing,commissioning etc., complete job as on when required.
2
-
-
... More
Rewinding of 1 HP, 1 Ph Submersible motor , Rewinding of following capacity submersible STP motors by dismantling, cutting of burnt out wire, rewinding with new suitable guage enamelled fine copper wire, varnishing, baking, re-assembling,complete overhauling of the motor including To & fro transportation to the site etc., complete job as on when required.
1 HP , 1- Phase Submersible motor
5
-
-
... More
Rewinding of 3 HP-3Ph submersible motor , Rewinding of following capacity submersible STP motors by dismantling, cutting of burnt out wire, rewinding with new suitable guage enamelled fine copper wire, varnishing, baking, re-assembling,complete overhauling of the motor including To & fro transportation to the site etc., complete job as on when required.
3 HP, 3-Phase submersible motor
3
-
-
... More
Rewinding of 5 HP-3Ph submersible motor , Rewinding of following capacity submersible STP motors by dismantling, cutting of burnt out wire, rewinding with new suitable guage enamelled fine copper wire, varnishing, baking, re-assembling,complete overhauling of the motor including To & fro transportation to the site etc., complete job as on when required.
5 HP , 3- Phase submersible motor
5
-
-
... More
Rewinding of 1.75 HP submersible motor , Rewinding of following capacity submersible STP motors by dismantling, cutting of burnt out wire, rewinding with new suitable guage enamelled fine copper wire, varnishing, baking, re-assembling,complete overhauling of the motor including To & fro transportation to the site etc., complete job as on when required.
1.75 HP Submersible motor
3
-
-
... More
Rewinding of 1 HP capacity Monoblock motor , Rewinding of following capacity Monoblock motors by dismantling, cutting of burnt out wire, rewinding with new suitable guage enamelled fine copper wire, varnishing, baking, re-assembling,complete overhauling of the motor including To & fro transportation to the site etc., complete job as on when required.
1 HP Monoblock motor
2
-
-
... More
Rewinding of 5 HP capacity Monoblock motor , Rewinding of following capacity Monoblock motors by dismantling, cutting of burnt out wire, rewinding with new suitable guage enamelled fine copper wire, varnishing, baking, re-assembling,complete overhauling of the motor including To & fro transportation to the site etc., complete job as on when required.
5 HP Monoblock motor
1
-
-
... More
Rewinding of 12.5HP capacity Monoblock motor , Rewinding of following capacity Monoblock motors by dismantling, cutting of burnt out wire, rewinding with new suitable guage enamelled fine copper wire, varnishing, baking, re-assembling,complete overhauling of the motor including To and fro transportation to the site etc., complete job as on when required.
12.5 HP Monoblock motor
1
-
-
... More
Replacement of worn out , Replacement of worn out / broken pully rubber belt of size B60 of blower motor etc., complete as on when required.
8
-
-
... More
AMC of Fire hydrant and sprinkler system , Annual Maintenance of Fire hydrant & sprinkler system of Terminal Building and Cargo Building by carrying out Preventive maintenance Inspections, attending to complaints / breakdowns, maintaining records by providing trained manpower, tools, consumables, cleaning materials etc. complete as required as per enclosed Preventive maintenance Schedule, Special conditions of contract and Particular specifications etc. complete as required.
The contractor shall engage minimum man power per day as per the particular specifications.
24
-
-
... More
CMC of Intelligent addressable Fire alarm at MSSR , Comprehensive Maintenance contract of the intelligent addressable type Fire Detection and Alarm system alongwith all its associated accessories installed at MSSR building at yarada hills, by carrying out complete comprehensive maintenance, providing spares etc., carrying out Preventive maintenance Inspections, attending to complaints and breakdowns, maintaining records by providing trained manpower, tools, consumables, cleaning materials etc. complete as required as per enclosed Preventive maintenance Schedule and OEM recommendations, Special conditions of contract and Particular specifications etc. complete as required.
1. Fire alarm panel (Make -Edwards) - 1 no.
2. Detector (Make- Edwards) - 75 nos.
3. Manual call point (Make- Edwards) - 5 nos.
4. Hooter (Make - Edwards) - 5 Nos.
5. Auto dialer (Make - Securico) - 01 No.
24
-
-
... More
CMC of Conventional type Fire alarm system , Comprehensive Maintenance contract of the conventional type panel with auto dialler, Fire Detection and Alarm system alongwith all its associated accessories installed at various locations viz., CNS equipment rooms, Power house locations by carrying out complete comprehensive maintenance, providing spares etc. and carrying out Preventive maintenance Inspections, attending to complaints and breakdowns, maintaining records by providing trained manpower, tools, consumables, cleaning materials etc. complete as required as per enclosed Preventive maintenance Schedule and OEM recommendations, Special conditions of contract and Particular specifications etc. complete as required. No. of devices connected to each individual control panel are detailed in Particular Specifications.
1. Localizer -01 No 2.Glidepath-01 No
3.DVOR-01 No
4.Power house-01 No
5.Engg.Office-01 No
6. Edvor, Yarada (Old)-01 NO
7. Edvor, Yarada (New)-01 NO
24
-
-
... More
CMC of Intelligent addressable Fire alarm at Cargo Building , Comprehensive Maintenance contract of the micro processor(inteligent type) controlled analogue addresable fire alarm control panel to accommodate above devices in loops with all acessories, solid state design, neatly wired painted as per standars with built in SMF batteries of reputed make. Arrangement for 24 hours back up time with battery charger and batteries. The panel have minimum following facilities 1. Fire alarm (Make Honey well) - 01 No.
2. Smoke Detectors (Make Honey well) - 129 Nos
3. Heat Detectors (Make Honey well) - 4 Nos
4. Hooters (Make Agni) - 9 Nos.
5. Beam Detecters (Make Honey well)- 06 Nos
6. Loop Isolators(Make Honey well)-10 Nos
7. Manual Call point (Make Agni)-23 nos
Location - International Cargo Building.
24
-
-
... More
DSR 2022 , Quote for Rs. 6,00,000.00 (including GST) of DSR 2022 (Electrical) schedule of works.
Note The rate may be quoted in the following manner (i) If quoted rate is Rs. 6,06,000.00 (including GST and Cess) then the percentage will considered as 0% above or below DSR 2022.
(ii)If quoted rate is Rs. 5,45,400.00 (including GST and Cess) then the percentage will considered as 10% below DSR 2022.
(iii) If quoted rate is Rs. 6,66,600.00 (including GST and Cess) then the percentage will considered as 10% above DSR 2022
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements