Military Engineer Services Tender

To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date19 Nov 2024
Closing Date3 Dec 2024
Tender Amount₹ 42,00,000 
Notes
Download

Costs

Summary

Repair/replacement, Maint Of Sewage Treatment Plant, Dosing Pumps, Filter Media And Its Allied Works At Minniebay, Vayu Vihar And Brookshabad And Repair/ Maint And Cleaning Of Dg Set, Boom Barriers Hanger Motors And Other Connected Works At Ins Utkro

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F in replacement harness wiring suitable for 62.5 to 320 KVA DG set as per existing make and model and connecting with DG set operating system complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F in replacement shutdown valve suitable for 62.5 to 320 KVA DG set as per existing make and model complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F in replacement of magnetic pick up suitable for 62.5 to 320 KVA DG set as per existing make and model complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F in replacement of AVR unit as per existing make and model and suitable for DG set 63 / 82.5 /100/ 125 KVA incl connecting with alternator and control panel circuits, starting and testing complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F in replacement of AVR unit as per existing make and model and suitable for DG set 160/200/250/320 KVA incl connecting with alternator and control panel circuits, starting and testing complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F in replacement rotating rectifier assembly as per existing make and model and suitable for DG set 125/160 / 200 /250/320KVA complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F in replacement rotating rectifier assembly as per existing make and model suitable for DG set 25/62.5/82.5/100 KVA complete all as directed by Engineer-in-Charge.

1

-

-

... More
M & L for B check (Every 300 hours/06 months),"C" check (Every 1500 hrs)/01 years) and "D" check (Every 6000 hours/02 years) as per maintenance schedule of Disel Engines set of capacity 25 KVA for Kirloskar/ Cummins/ Cotton greaves / as per OEM including changing of lub oil, oil & fuel filters, Fuel sup, sys, Cooling sys, Air Sys, Lubrication sys and other maintenance check vibration, Check Air compressor, adjust to injectors and valves, Replaces rocker cover gaskets etc all as specified by the manufacturer and as directed by the Engineer-in-Charge. Note : (i) Engine oil & coolant shall be measured and paid separately under relevent item of this schedule. (ii) "C" & "D" check will be done as per PRRB fullfilled (Hrs/ Years). (iii) The cost of Fuel sup sys, Cooling sys, Air cooling Sys, Lubrication sys and other maintenance to check vibration, Check Air compressor, adjust to injectors, Valves, Replaces rocker cover gaskets etc required for this job are deemed inclusive in the rates.

2

-

-

... More
All as per item No 11 above but for DG set of capacity 62.5 KVA

3

-

-

... More
All as per item No 11 above but for DG set of capacity 82.5 KVA

2

-

-

... More
All as per item No 11 above but for DG set of capacity 100 KVA

1

-

-

... More
All as per item No 11 above but for DG set of capacity 125 KVA

2

-

-

... More
All as per item No 11 above but for DG set of capacity 160 KVA

2

-

-

... More
All as per item No 11 above but for DG set of capacity 200 KVA

2

-

-

... More
All as per item No 11 above but for DG set of capacity 250 KVA

1

-

-

... More
All as per item No 11 above but for DG set of capacity 320 KVA

2

-

-

... More
M & L for B check maintenance of 156 HP drainage pump for Kirloskar / as per OEM including changing of lub oil, oil, coolant & fuel filters all as specified by the manufacturer and as directed by Engineer-in-Charge. Note : Engine oil & coolant shall be measured and paid separately under relevent item of this schedule

2

-

-

... More
M & L for repair and reconditioning of battery charge alternator 24 V DC for Cummins/ as per OEM including taking out the defective alternator from 100/125 / 160 KVA / 200 KVA/250/320 capacity DG set , complete dismantling and repair and replacing the carbon brushes, rectifier diode set, bearing and bush, regulator control, refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-Charge.

1

-

-

... More
M & L for repair and reconditioning of battery charge alternator 12 V DC cummins/ as per OEM including taking out the defective alternator from 25 / 62.5 KVA / 82.5 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes, rectifier diode set, bearing and bush, regulator control, refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply only coolant for radiator suitable for DG set of capcity 25/62.5 / 100/ 125 / 160/200/250/ 320 KVA of Make- Cummins/ Cotton greave/ Kirloskar under cat part no 3167215 all as per manufacturers recommendations and directed by Engineer-in-Charge.

60

-

-

... More
Supply only engine oil suitable grade SAE-20W40/ as per OEM recommendation complete all as specified and directed by Engineer-in-Charge.

600

-

-

... More
M & L for fixing in replacement of asbestos rope 12 mm dia for wrapping the exhaust pipe of DG set all as directed by Engineer-in-Charge.

20

-

-

... More
M & L for fixing in replacement of Air filter of 25/62.5/100/125 KVA DG set of OEM make all as specified and directed by Engineer-in-Charge.

3

-

-

... More
M & L for fixing in replacement of Air filter of 160 / 200/250 / 320 KVA DG set of relevant OEM make all as specified and directed by Engineer-in-Charge.

2

-

-

... More
M & L for fixing in replacement of water pump for DG sets of capacities 100/125/160 / 200/320/250 of relevant OEM make complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
M & L for fixing in replacement of water pump for DG sets of capacities 25/ 62.5/82.5 KVA of relevant OEM make complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
M & L fixing in replacement of fan belt (each set) in 25/62.5/82.5/100 / 125 KVA DG set of make Cummins/ Cotton greave/ Kirloskar cat part no. 178623 complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
M & L for fixing in replacement of fan belt (each set) in 160/ 200/ 250 /320 KVA DG set of Make- Cummins/ Cotton greave/ Kirloskar part no. 178611 complete all as specified and directed by Engineer-in-Charge

3

-

-

... More
M & L for fixing in replacement of belt water pump (each set) in 25/62.5/82.5/100/125 KVA DG set of Make- Cummins/ Cotton greave/ Kirloskar part no.200328 complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
M & L for fixing in replacement of belt water pump ( each set ) in 160/200/250/320 KVA DG set of Make- Cummins/ Cotton greave/ Kirloskar complete all as specified and directed by Engineer-in-Charge

3

-

-

... More
M & L for repair and reconditioning the starting motor of Kirloskar / Cummins / Greaves as per make / model at site including taking out the defective starter from 160 KVA / 200 KVA /250/320KVA capacity DG set, complete dismantling and repair and replacing the carbon brushes with holder, solenoid switch assly, bush, commutator unit, stator running coil unit , stator starting coil etc and connecting with the circuit including all required items, starting and testing complete all as specified and directed by Engineer-in-Charge . Note : Supply only of spare parts shall be measured and paid separately under relevent item of this Schedule

2

-

-

... More
Supply only Carbon brush set with holder as per existing make and model suitable for 160 KVA / 200 KVA /250/320KVA capacity DG set complete all as specified and directed by Engineer-in-Charge .

2

-

-

... More
Supply only Solenoid switch assembly with bush as per existing make and model suitable for 160 KVA / 200 KVA /250/320KVA capacity DG set complete all as specified and directed by Engineer-in-Charge .

3

-

-

... More
Supply only commutator unit as per existing make and model suitable for 160 KVA / 200 KVA /250/320KVA capacity DG set complete all as specified and directed by Engineer-in-Charge .

2

-

-

... More
Supply only stator starting coil unit as per existing make and model suitable for 160 KVA / 200 KVA /250/320KVA capacity DG set complete all as specified and directed by Engineer-in-Charge .

2

-

-

... More
M & L for repair and reconditioning the starting motor of kirloskar / Cummins / Greaves make including taking out the defective starter from 25/62.5/82.5/100/125 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes with holder, solenoid switch assly, bush, commutator unit, stator starting coil, stator running coil etc and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-Charge. Note : Supply only of spare parts shall be measured ana paid separately under relevent item of this Schedule

1

-

-

... More
Supply only carbon brush set with holder as per existing make and model suitable for 25/62.5/82.5/100/125 KVA capacity DG set complete all as specified and directed by Engineer-in-Charge .

2

-

-

... More
Supply only Solenoid switch assembly with bush as per existing make and model suitable for 25/62.5/82.5/100/125 KVA capacity DG set complete all as specified and directed by Engineer-in-Charge .

3

-

-

... More
Supply only commutator unit as per existing make and model suitable for 25/62.5/82.5/100/125 KVA capacity DG set complete all as specified and directed by Engineer-in-Charge .

3

-

-

... More
Supply only stator starting coil unit complete as per existing make and model suitable for 25/62.5/82.5/100/125 KVA capacity DG set complete all as specified and directed by Engineer-in-Charge .

1

-

-

... More
Supply only stator running coil unit as per existing make and model suitable for 25/62.5/82.5/100/125 KVA capacity DG set complete all as specified and directed by Engineer-in-Charge .

2

-

-

... More
M&L for repairs of copper/ aluminium type radiator for DG set of capacities 25/62.5/82.5/100/125 KVA, taking out by disconnecting from DG set and locating the leaking places and soldering/ brazing complete with cleaning by acid and refixing in position including replacement of old hose pipe with new complete all as specified and directed by Engineer-in-Charge. Note : Cost of oil hose shall deemed to be included in the quoted rate.

2

-

-

... More
M&L for repairs of copper / aluminium type radiator for DG set of capacities 160 KVA / 200 KVA /250/320KVA KVA KVA DG Sets ,taking out by disconnecting from DG set and locating the leaking places and soldering/ brazing complete with cleaning by acid and refixing in position including replacement of old hose pipe with new complete all as specified and directed by Engineer-in-Charge at site. Note : Cost of oil hose shall deemed to be included in the quoted rate.

2

-

-

... More
Supply and fix in replacement of Lub oil hoses set complete for DG set of capacity 25/62.5/82.5/125/160/200 KVA complete all as directed by Engineer-in-Charge

2

-

-

... More
S&F in replacement of 3 pole ML- 4 Contactor, heavy duty with aux contacts 415 Volt all as per existing make and model complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F in replacement of 220 / 415 Volt Coil suitable for ML- 4 Contactor as per existing make and model complete all as specified and by Engineer-in-charge.

2

-

-

... More
M&L for taking down stator assembly of alternator 25 KVA to 320 KVA DG Sets by disconnecting electrically and mechanically complete cleaning with CTC and decarbonising the stator , rotor and excitor coils, heating the coils for achieving insulation upto the mark, checking thoroughly the complete system and connections and replacing the defective insulation paper by applying Dr Beck varnish baking / heating and bringing back to installation and refixing and assembling the same Connecting electrically , mechanically and testing on completion of work complete all as by Engineer-in-charge.

1

-

-

... More
M & L for attending breakdown / inspection and rectifying defects of 25 KVA to 320 KVA DG Sets as and wherever required for smooth operation including AMF and Electrical Panel to check and locate / detect fault related to breakdown complete all as directed by Engineer-in-Charge. Note:- (a) Spares will be measured and paid separately under relavant items. (b) The break down complaint should be attended within 2 hours with the intimation of Engr-in-charge or concern JE E/M by telephonically / verbally. (c) Not attended of complaint within two hours will lead to recovery from subsequent payment in the following manner :- (i) Not attending within 2 to 4 Hours - Rs. 1000.00 (ii) Not attending within 4 to 6 Hours- Rs. 2000.00 (iii) Not attending within 6 to 8 Hours- Rs. 3000.00 (iv) Not attending after 8 Hours - Rs. 4000.00 (v) The maximum recovery will be Rs. 5000.00 plus the expenditure incurred for rectification of the same by any other means.

8

-

-

... More
S&F in replacement of maintenance free lead acid battery 12 Volt,180AH capacity complete with brass terminals including testing on load complete all as specified and by Engineer-in-charge.

3

-

-

... More
S&F in replacement maintenance free lead acid battery 12 volt 150 AH capacity all complete with brass terminals including testing on load complete all as specified and by Engineer-in-charge.

2

-

-

... More
S&F in replacement maintenance free lead acid battery 12 volt 130 AH capacity complete with brass terminals including testing on load complete all as specified and by Engineer-in-charge.

3

-

-

... More
Supply and fill distilled water for batteries 12 volt 180 / 150 AH / 130 AH all as specified and directed by Engineer-in-Charge

90

-

-

... More
S&F in replacement of Automatic battery charging unit with indication of automatic charge, float with charge indication and cut off 220 V input AC and output 12/24 V DC, 10 Amps and testing with DG sets complete all as specified and by Engineer-in-charge.

3

-

-

... More
S&F in replacment of alternator terminal connector in 62.5 to 320 KVA by taking out the burnt connector from alternator, checking cable lugs including testing complete all as specified and by Engineer-in-charge.

3

-

-

... More
S&f in replacement exhaust manifold set of three pieces complete with gaskets , stud mountings, nuts etc complete ( centre , rear and front) as per existing make and model of 320/250/ 200 / 160 KVA DG set all as specified and as directed by Engineer-in-Charge.

1

-

-

... More
S&F in replacement of PT fuel pump by dismantling, transporting, repairing and calibration, testing and commissioning of PT fuel pump for 160 / 200 KVA/250/320KVA DG set including the replacement of all service kits, pulsvation damper, tacho drive shaft and seal, gear drive shaft , bearing, weight carriers, etc all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F in replacement of PT fuel pump by dismantling, transporting, repairing and calibration, testing and commissioning of PT fuel pump for 25/62.5/82.5/100/125 KVA DG set including the replacement of all service kits, pulsvation damper, tacho drive shaft and seal, gear drive shaft , bearing, weight carriers, etc all as specified and directed by Engineer-in-Charge.

4

-

-

... More
M&L for taking down stator assembly of alternator of DG set of capacity 25/62.5/82.5/100/125 KVA by disconnecting electrically and mechanically taking to work shop for rewinding incl removing burnt coils, insulating material complete cleaning with CTC and rewinding with same gauge ISI marked winding wire complete with ISI marked insulating paper and Dr Beck varnish baking / heating and bringing back to installation refixing , connecting electrically and mechanically and testing on completion of work complete all as specified and by Engineer-in-charge.

2

-

-

... More
All as per item No 61 above but alternator for DG set of capacity 160/ 200 KVA/250/320KVA by Engineer-in-charge.

1

-

-

... More
S&F in replacement and commissioning 24 V DC heavy duty starter motor as per existing make and model suitable for 160 / 200/250 KVA Cummins / Kirloskar DG set all as directed by Engineer-in-Charge.

1

-

-

... More
S&F in replacement and commissioning 12 V DC heavy duty self starter motor as per existing make and model suitable for 125/82.5/ 62.5 KVA Cummins / Kirloskar DG set all as directed by Engineer-in-Charge.

1

-

-

... More
M&L for fixing in replacement of DG Set door Hinges & accessaries for 25 KVA to 320 KVA DG Sets complete all as by Engineer-in-charge.

2

-

-

... More
M&L for fixing in replacement of solid state potentiometer of 25 to 320 KVA DG set and testing as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F in replacement fan pulley assembly of 25 to 320 KVA DG Set as per existing make and model complete all as by Engineer-in-charge.

1

-

-

... More
S&F in replacement DG set control panel into Digital electronic control panel with mounting bracket with vibration isolating pads -3 nos of 25 to 320 KVA DG Sets as per existing make and model complete all as directed by Engineer-in-Charge.

1

-

-

... More
S&F in replacement of selector switch 2 way type and 10 Amps rating capacity, connecting with 25 to 320 KVA DG set as per existing make and model including alternator parallel circuit connection and testing complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F in replacement of Push button ( 2 nos ) as per existing make and model for ON / Off 25 to 320 KVA AMF panel connecting with control circuit including connection and testing complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
S&F in replacement of coolant hose set Cummins part no. 67185 - 4 nos, 63495 - 2 nos, AK 5045 SS - 1 no, AK 16030 SS - 1 no, AK 16018 MS - 1 no including set of clamps complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
S&F in replacement of Housing actuator under Cummins Part no.3166630 in 25 to 320 KVA DG set by taking out old from fuel pump complete all as specified and directed by Engineer-in-Charge

3

-

-

... More
S&F in replacement of drive accessory under Cummins cat pat No 3005123 in 25 to 320 KVA DG set all as directed by Engineer-in-Charge

2

-

-

... More
S&F in replacement seal accessory under Cummins cat part no 212227 in 25 to 320 KVA DG set all as directed by Engineer-in-Charge

1

-

-

... More
S & F in replacement Electronic Governor controller under Cummins part no.3413905 in 25/62.5/82.5/125/160/200/250/320 KVA DG set and testing all as specified and dicrected by Engineer-in-charge

1

-

-

... More
Supply, installation and commissioning of radiator for 125/160/200/250/320 KVA Cummins DG set under Cummins cat part no. 4020300 including dismantling of old / defective radiator, taking out from DG set base frame, fixing the new radiator assembly, fan and shroud of radiator, connecting cooling pipes inlet and outlet all as directed by Engineer-in-Charge.

1

-

-

... More
S&F in replacement of AMF Logic controller (Microprocessor based type) by taking out the defective unit from 25 / 62.5/ 82.5/100/125 /320 KVA capacity DG set as per existing make and model complete checking the panel and its connection circuit in the panel board, providing prper interlink connection with DG set including all required items, starting and testing all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F in replacement start and stop relay 12 V/24 V DC suitable for AMF Panel capacity of 25 to 320 KVA all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S & F in replacement of heavy duty Exhaust fan 600mm Sweep 240 volt , Opal White / brown including bracket, nut bolts and making hole for fitting fan on wall including all accessories and handing over of old unserviceable exhaust fan to MES storeyard complete all as specified and as directed by Engineer-in-Charge

1

-

-

... More
S&F in replacement of wall mounted fan (Air circulators) Turbo Force 600mm sweep including all accessories and handing over of old unserviceable wall mounted fan to MES storeyard complete all as specified and as directed by Engineer-in-Charge

1

-

-

... More
Dismantling iron sections as in chequred plate and frame work to plates in any size and position complete all as specified and directed.

0.7

-

-

... More
S&F Mild steel Plates (plain or chequred) plate channels squre cut or notched forming holes, without any attachement incl necessary welding as specified and directed by Engineer-in-Charge.

20

-

-

... More
S&F Rolled steel sections as in main and cross beam, frame work to ducts for laying chequred plates and similar work including necessary welding, grouting using PCC 1:3:6 and making good to surface as required

50

-

-

... More
M&L for applying two coats of synthetic enamel paint over a coat of red oxide, Zinc chrome primer on steel surfaces of any descrption , over 10cm width or girth, including preparing new steel surfaces complete all as specified and directed by Engineer-in-Charge.

18

-

-

... More
S&F in replacement of digital panel board inclusive of Ammeter, Voltemeter , start and stop buttuns, oil temeprature , water pressure gauge , battery status indicator , suitable for 156 HP dainage pump all as specified and directed by Engineer-in-Charge

1

-

-

... More
M&L for writing MES NO of DG set in white / black colour, minimum 15 letters complete all as specified and directed by Engineer-in-Charge. Note : Min of 15 letters shall be considered as one job

10

-

-

... More
M&L for cleaning of fuel tank made of MS sheet up to 320KVA DG Sets by draining out fuel in a separate container, taking out all silt / dirt deposition inside the tank, cleaning it completely by manual and necessary T&P and refitting and connecting with fuel pipes complete all as specified and as directed by Engineer-in-Charge

4

-

-

... More
S&F of battery lead with stranded copper conductor of size 70 sqmm single core PVC insulated flexible 0.6 M long along with battery terminal for positive and stator terminal duly soldered complete all as directed by Engineer-in-Charge.

2

-

-

... More
Taking out of Engine head from engine assembly, cleaning of engine head complete, taking out all parts, de-carbonising of engine head by head grinding and polishing, existing head sheets cutting, new valve socket sheets fixing as per original shape and size, replacement of inlet valves, outlet valves, valve guides etc. including valve grinding and polishing, return back of enging head from workshop, refitting of engine head to engine top including replacement of head gasket complete set, tunning and testing of engine at full load complete all as specified and directed by Engineer-in-Charge for 62.5/82.5/100 KVA capacity DG set. Note : (i) The cost of cleaning materials like kerocine oil, cotton waste etc. and lubricating item like mobile oil, greese etc. required for this job are deemed inclusive in the rates. (ii) Valve sheet, inlet & exhaust valve, valve guide and head gasket set are to be measured and paid separately in the relevant item of this schedule as " Supply only" Items below.

2

-

-

... More
Supply only exhaust valve suitable for 25/62.5/82.5/125/160/200/250/320 KVA DG set as per same shape and size complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply only valve guide suitable for 25/62.5/82.5/125/160/200/250/320 KVA DG set as per same shape and size complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply only head gasket assembly suitable for 25/62.5/82.5/125/160/200/250/320 KVA DG set as per same shape and size complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
Supply only piston suitable for 25/62.5/82.5/125/160/200/250/320 KVA DG set as same shape and size complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
Supply only piston PIN suitable for 25/62.5/82.5/125/160/200/250/320 KVA DG set as same shape and size complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
Supply only piston ring suitable for 25/62.5/82.5/125/160/200/250/320 KVA DG set as same shape and size complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
Supply only connectig rod suitable for 25/62.5/82.5/125/160/200/250/320 KVA DG set as per same shape and size complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
Supply only main bearing suitable for 25/62.5/82.5/125/160/200/250/320 KVA DG set as per same shape and size complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
Supply only thrust bearing with washer suitable for 25/62.5/82.5/125/160/200/250/320 KVA DG set as per same shape and size complete all as specified and directed by Engineer-in-Charge

3

-

-

... More
Supply only camshaft suitable for 25/62.5/82.5/125/160/200/250/320 KVA DG set as per same shape and size complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
Materials and labour for tapet cover opening, tapet adjisting and setting and refitting all including replacement of Tapet cover packing suitable upto 25/62.5/82.5/125/160/200/250/320 KVA DG set all as speciifed and as directed by Engineer-in-Charge.

1

-

-

... More
Taking out FIP from engine assembly shfiting of FIP to work shop overhauling of FIP complete after replacement of unserviceable parts callibration of FIP returning from workshop refixing to engine assembly including replacement of nozzles and cleaningof nozzle pipes complete all as specified and directed by Engineer-in-Charge for 25/62.5/82.5/125/160/200/250/320 KVA DG capacity by DG set. Note :- (i) The cost of cleaning materials like kerosine oil cotton waste etc and lubricating item like mobile oil grease etc and patty spare parts required for this Job are deemed inclusive in the rates. (ii) Nozzles and 'O' rings are to be measued and paid separatly as "Supply only " Items below.

1

-

-

... More
Supply only FIP nozzle suitable for 25/62.5/82.5/125/160/200/250/320 KVA DG ste as per same shape and size all as specified and directed by Engineer-in-Charge

1

-

-

... More
Supply only 'O' ring suitable for 25/62.5/82.5/125/160/200/250/320 KVA DG ste as per same shape and size all as specified and directed by Engineer-in-Charge

2

-

-

... More
S&F for Submersible water proof cable 3 core 35 Sqmm copper cable flat type complete all as specified and as directed by Engineer-in-Charge.

21

-

-

... More
S&F in replacement cable PVC insulated sheathed, unarmoured, round water proof with stranded copper conductor 1100 V grade of size 4 core 16 Sq mm for hanger motor up to 25 Mtr height and necessary clamp to move the round cable all as directed by Engineer-in-Charge at site.

20

-

-

... More
S&F in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 100 Amps.as per existing make and model complete all as directed by Engineer-in-Charge.

1

-

-

... More
S&F in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 125 Amps. as per existing make and model complete all as directed by Engineer-in-Charge.

1

-

-

... More
M&L for disconnecting electrically and mechanically defective induction electric motor from hanger door/ STP bed of capacity of 5 HP electrically operated three phase 415 volt, shifting to civil workshop for repair, strip opening for inspection, cutting of unserviceable burnt winding, taking out, cleaning of slots, rewinding with new super enameled ,copper conductor winding wire and replacement of u/s burnt insulating materials, sleeves etc,varnishing and other connected works,re-assembling,re-fixing at site, electrical connection fixing with pump set with nuts,bolts,washers as per original position and testing complete all as directed by Engineer-in-Charge.

2

-

-

... More
M&L for disconnecting electrically and mechanically defective gear box assembly from hanger motor of capacity of 5 HP electrically operated three phase 415 volt,shifting to civil workshop for repair,strip opening for inspection, taking out unserviceable bearing, cleaning of slots, and replacement u/s gear pinion, back axile and filling with gear oil ,re-assembling,re-fixing at site as per original position and testing complete all as directed by Engineer-in-Charge.

1

-

-

... More
S & F in replacement of digital soft starter suitable for 15 HP submersible pump including all connection and additional wiring etc all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F in replacement on load change over switch 415 V, 4 pole,200 A open execution as per existing make and model suitable equivalent make as per list of make at PS complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
M & L for increasing length 2.0 RM of exhaust manifold pipe to the length 2.0 RM as per site requirement to throw the smoke out of the DG set sheds for DG sets of capacity up to 320KVA DG Set shed including connecting pipe of existing size, two coat of synthetic enamel paint over a coat of red oxide with nut bolts washer coupler/ welding etc as per site requirement including wrapping the pipe with size rope all as specified and as directed by Engineer-in-Charge

1

-

-

... More
M & L for taking out and serviceing automatic electrically operated boom barrier complete assembly cleaning, greasing, oiling, de-carbonising of all parts of barrier box, automatic barrier gates, straight arm folding/fencing type, traffic mirror, photo sensor, control card and boom rest stand in workshop, refitting including replacement all connected accessories complete testing all as specified and directed by Engineer-in-Charge. Note : (i) The cost of cleaning materials like kerocine oil, cotton waste etc. and lubricating item like mobile oil, greese etc. required for this job are deemed inclusive in the rates. (ii) All parts of barrier box, traffic mirror, photo sensor control card and boom rest stand are deemed to be included in the quoted rate. (iii) Automatic barrier gates, straight arm to be measured and paid separately in the relevant item of this schedule as " Supply only" Items below.

2

-

-

... More
Supply only automatic barrier gates, straight arm as per same/ existing shape and size complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
Design, supply, installing testing and commissioning factory fabricated out door type totally enclosed LT cubical panel board suitable size with busbar, conforming to relevant IS and protection class IP-65 ,dust,vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on 40x40x5mm MS angle iron frame, duly welded in shape and coated with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate, panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables, locking arrangement, including accommodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engineer-in-Charge including Supply and fixing the following :-

1

-

-

... More
(a) MCCB TPN 320 Amps 50 Hz, 415 V with rupturing capacity 50 KA-1 No (Incoming) (b) MCCB 160 Amps 50 Hz, 415 V with rupturing capacity 25 KA-02 Nos (Outgoing) (c) MCCB TPN 100 Amps 50 Hz, 415 V with rupturing capacity 25 KA - 02 Nos (Outgoing) (d) Voltmeter 0-500V with selector switch (Digital type)-01 No (e) Ammeter 0-500 Amps with CTs (500/5Amps) and selector switch(Digital type)-01 No (f) Indicating lamps (RYB) -01 Set (g) PCC Foundation (Civil works) for grouting of panel

-

-

-

... More
M&L of cleaning of Oil and Grease chamber,Equalization tank,MBBRs, Screening Bar and Centrifuse filter press Chlorine contact tank including cleaning of pumps, LT Panels, DG Set, tertiary filters, micro filter, dosing drums, motors and cleaning will be carried out twice a month for Sewage Treatment Plant of capacity 200 KLD at Brookshabad (electrically operated containing the machinery) all as specified and as directed by Engineer-in-Charge. Note :- (i) All chemicals required for smooth functioning of STP shall be measured and paid separately under appropriate items. (ii) Cleaning of Oil and Grease chamber, Screening Bar and Centrifuse filter press and removal of sludge cake shall be carried out.

18

-

-

... More
All as per item No.117 but 125 KLD Sewage treatment plant at Ajay Baugh area.

18

-

-

... More
All as per item No.117 but 50 KLD Sewage treatment plant at Pereira enclave area.

18

-

-

... More
M/L in collection of dried sludge cake from STP once in a month and disposed of safely to a suitable place not more than 10 KM form STP Minniebay location complete all as specified and directed by Engineer-in-Charge.

27

-

-

... More
M&L for treatment of STP water with dewatering Polyelectrolysis cationic solution of 0.075% concentration chemical compound shall,consist of fifty kilogram packaging complete all as specified and directed by Engineer-in-Charge

9

-

-

... More
M&L for treatment of STP water with Sodium hypochlorite consisting 6% chlorine content chemical compound shall consist of fifty kilogram packaging complete all as specified and directed by Engineer-in-Charge

27

-

-

... More
M&L for treatment of STP water with enzyme-2 (DAP consisting 18:46:0,18% Nitrogen and water soluble phosphate 46% chemical shall consisting of fifty kilogram packaging complete all as specified and directed by Engineer-in-Charge

27

-

-

... More
M&L for bacteria Culture for STP for developing MLSS and control odour consisting of fifty kilogram packaging complete all as specified and directed by Engineer-in-Charge .

1

-

-

... More
M&L for treatment of STP water with calcium Hypochloride 65-70% chlorine content in granular form chemical will consist of fifty kilogram packaging complete all as specified and directed by Engineer-in-Charge

27

-

-

... More
M&L for Collecting the waste water/effluent sample monthly from STP(Minniebay Area and Brookshbad) before and after treatment, sample handling, transporting to NABL accredited lab approved by authorities, carry out the analysis of the followingas per IS 10500and submit records. (i)BOD(Bio chemical Oxygen Demand) (ii)COD (Chemical Oxygen Demand) (iii)TSS(Total Suspended Solids) (iv)Total dissolved solids (v)Turbidity (vii)PH

27

-

-

... More
M&L for cleaning of underground sewage treated water sump 50000 ltr by using pump set or bucket & mug etc complete all as directed by Engineer-in-Charge. (b) Removing sludge muds, silt sand etc from inside of tank and depositing in pit (depth of pit not less than 1.5 mtr) to a distance n.exc 50 mtr from tank including exacavation of suitable size of pit and returning, filling etc cleaning of tank with water and all as directed by Engineer-in-Charge. (c ) Removing moulds, moss,foreign materials etc from the internal surfaces of tank and from the mouth of pipe by scrapping with steel brushes/steel wool or steel scrapping, disposing off waste materials to a distance n.exc 50 mtr and cleaning the internal surface with clean water. (d) Spreading thin layers of bleaching powder over the entire internal surface area of tank internally and washing with clean water.(e) Applying one coat of lime wash to the internal surfaces. (f) Applying two acrylic exterior emlonson paint to the external surfaces of sump.

2

-

-

... More
All as per item no.127 but upto 30000 ltr capacity of sewage treated water sump.

2

-

-

... More
M&L for dismantling of non - clogging sewage submersible pumping set of 1HP/2 HP capacity from STP plant and transportation to workshop for repair dismantlng of pumping set complete segregating the serviceable parts for re-use and removing the defective parts, repair the pump throughly including machine work re-assembling the pump set and shifting to location as directed by Engineer in Charge, making all electrical connection and testing complete on full load to the entire satisfaction of Engr-in-charge (new spares will be measured and paid separately).

3

-

-

... More
Supply only for repair of non clogging pump submersible type by checking and cleaning throughly and replacing the following defective parts, reassembling the same and testing including installation in position all as directed by Engineer-in-Charge. Line shaft - 04 Nos Bearings - 08 Nos Water seal - 06 Nos Casing king key - 06 Nos

2

-

-

... More
M&L for two coats of colour washing paint of MBBR-1,MBBR-2 out side surface and before painting preparation of old painted surfaces of any description complete and all as specified and directed by Engineer-in-Charge.

6

-

-

... More
M&L for two coats of colour washing paint of Tube settler outside surface and before painting preparetion of old painted surfaces of any description complete and all as specified and directed by Engineer-in-Charge.

3

-

-

... More
M&L for two coats colour washing paint of Chlorine Cum filter feed tank of outside surface and before painting preparetion of old painted surfaces with sand paper and surface make smooth of any description,when unconnected with other painting or when painted in a different tint or otherwise as described complete and all as specified.

3

-

-

... More
M&L for two coats of epoxy enamelled paint over a coat of red oxide primer of Dual media filter/Activated carbon filter of size 1000mm dia x 1500mm and before painting preparetion of old painted surfaces with sand paper and surface make smooth of steel and iron of any description,when unconnected with other painting or when painted in a different tint or otherwise as described complete and all as specified by Engineer in Charge.

2

-

-

... More
M&L for taking down Hypo dosing pump and rewinding with suitable gauge of copper cunductor and testing as directed by Engineer-in-Charge by engineer in charge.

1

-

-

... More
M&L for taking down agitator and rewinding with suitable gauge of copper cunductor and testing as directed by Engineer-in-Charge by engineer in charge.

1

-

-

... More
M&L for taking down filter feed pump of capacity 3 HP and rewinding with suitable gauge of copper cunductor and testing as directed by Engineer-in-Charge by engineer in charge.

2

-

-

... More
M&L for opening for servicing/overhauling the monoblock pump and motor 5 HP and replacing the defective bearing, greasing replacing the burnout gland rope, studs, nuts, bolts, washers ,air releasing valve ,rubber gasket ,metal filling, turing/ grinding and balancing the shaft etc. varnishing the winding, drying and refixing the same all as specified and directed by Engineer-in-Charge.

2

-

-

... More
M&L for disconnection of electrical connection and dismantling of 10 HP non cloging monoblock pump from secondary clarifier mechanism, removing worn out winding wire from stator slots, rewinding with super enameled copper wire of suitable gauge with proper insulation replacement of front and rear bearing, assembling and reconnection electrical connection the same as existing and testing complete all as specified and as directed by Engineer in Charge.

1

-

-

... More
Supply and fixing in repair the following spares for dosing pumps at various incl taking down of unsv dosing pump.

-

-

-

... More
Fuse

3

-

-

... More
Ring seal teflon

2

-

-

... More
Stroke knob

2

-

-

... More
Pump panel box assy

2

-

-

... More
3/16 " x 3/4" pan head screw

4

-

-

... More
Pulser with varistor

1

-

-

... More
M&L for taking down air blower from the existing position after disconnecting all electrical connection and transportation to workshop for repair for un-serviceable parts complete and removing the defective parts, repair the air blower throughly including machine work and re-assembling the air blower and commssioning testing complete on full load all as specified and directed by Engineer-in-Charge

1

-

-

... More
M&L for disconnecting and isolating the air compressor/ air blower of any capacity from the system by placing dummy plates to suction and discharge valves, opening the compressor, removing all internal parts cleaning of all parts thoroughly, segregating unserviceable spare parts, complete service of compressors, supply and replacing the worn out parts viz., and replaced with new ones, refixing/reassembling the compressor unit, oil changing, testing for removing the dummy plates, leak testing of the compressor, testing and commissioning the compressor complete all as directed by Engineer-in-Charge.

1

-

-

... More
Supply and fixing in repair 10 HP air blower 'V' belt of sewage treatment plant complete all as specified and as directed by Engineer in Charge.

6

-

-

... More
Supply and fixing in repair star coupling of suitable size pump all as specified and directed by Engineer-in-Charge

6

-

-

... More
Supply and fixing in repair dosing pipe of suitable size of dosing pump all as specified and directed by Engineer-in-Charge

40

-

-

... More
Supply and fixing in repair NRV of suitable size of dosing pump all as specified and directed by Engineer-in-Charge

4

-

-

... More
Supply and fixing in repair the following spares for filter feed pumps of capacity 3 HP incl taking down filter feed pumps directed by Engineer-in-Charge.

-

-

-

... More
pump impler

2

-

-

... More
pump line shaft

2

-

-

... More
ball bearing. Make :- SKF or equivalent.

4

-

-

... More
pump water seal

6

-

-

... More
Gland.

6

-

-

... More
Supply and fixing in repair the following spares for treated water pumps of capacity 5 HP incl taking down filter feed pumps directed by Engineer-in-Charge by Engineer-in charge.

-

-

-

... More
pump impeller

2

-

-

... More
pump line shaft

2

-

-

... More
pump ball bearing. Make :- SKF or equivalent.

4

-

-

... More
pump water seal

4

-

-

... More
pump Gland.

4

-

-

... More
M&L for dismantling of diffusers from diffuser grid assembly of aeration tank and replacement of fine bubble type diffuser made of EPDM rubber extruded, diffuser frame fastner etc. complete all as specified and as directed by Engineer in Charge.

3

-

-

... More
Supply and fixing flat submersible 1100 Volts grade, 3 core copper conductor PVC insulated and PVC sheathed cable of 6 Sq mm including taking down old material.

50

-

-

... More
M & L for cleaning the Raw sewage collection RCC sump /open sump of size as per site.The cleaning includes the followings parts complete all as specified and as directed by Engineer in Charge. a)Dewatering the sump with portable submersible pump b)Removal of left over dirty water and sludge with a special sludge removal pump. c) Removal of remaining sludge from the floor with the help of industrial vacuum Cleaner. d)Spraying of Non-toxic, bio-degradable, eco-friendly anti-bacterial agent, to disinfect the tank from all harmful pathogens.

3

-

-

... More
Material and labour for cleaning of MS Activated carbon filter / MS Dual media filter of size 1000mm dia and 1500mm height ,cleaning of existing pipe holes after refill complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Taking out defective pebbles, Supply and Laying filter media (pebbles) of size 5mm and 3mm in filter beds complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
Taking out defective coarse gravel, supply and laying filter media (coarse gravel/fine gravel) in filter bed complete all as specified and directed by Engineer-in-Charge.

120

-

-

... More
Taking out defective carbon media, Supply and Laying carbon filter media IV 800 to 1000 (iodinevalue) for two nos filter complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
M & L for replacing fine sand in filter media beds complete all as specified and directed by Engineer-in-Charge.

110

-

-

... More
Supply and fixing in repairs Butterfly valves lever operated body grey cast iron of size 65mm bore, with all fittings confirming to IS specification complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and fixing in repairs CI/ Gunmetal Butterfly valves lever operated body grey cast iron of size 50 mm bore, with all fittings confirming to IS specification all as specified.

2

-

-

... More
M&L for taking down unserviceable sluice valves of following sizes as directed by Engineer-in-Charge by Engr-in charge :-

-

-

-

... More
80mm bore

2

-

-

... More
100mm bore

1

-

-

... More
Supply and fix sluice valve 80mm bore class PN1.0 including flange screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed all as specified and directed by Engineer-in-Charge. Make :-Kirloskar

1

-

-

... More
Supply and fix sluice valve 100mm bore class PN1.0 including flange screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed all as specified and directed by Engineer-in-Charge. Make :-Kirloskar

1

-

-

... More
Supply and fixing in repairs Butterfly valves lever operated body grey cast iron of size 25 mm bore, with all fittings confirming to IS specification all as specified.

2

-

-

... More
Supply and fixing in repairs non return sluice valves body grey cast iron of size 50 mm bore, with all fittings confirming to IS specification all as specified.

2

-

-

... More
S&F in replacement dosing pump for chemicals dosing having automatic operation having discharge flow upto 0-20 LPH suitable for chemical dosing all as specified and directed by Engineer-in-Charge

3

-

-

... More
Supply and fix in replacement of UPVC ball valve suitable for 40/50 mm UPVC pipe complete all as specified and as directed by Engineer-in-Charge.

5

-

-

... More
Supply and fix in replacement of UPVC multifunctional butterfly valve suitable for 40/50 mm UPVC pipe complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of 50mm dia UPVC pipes including fittings like elbow, tee, band etc on walls/ceilings/laying in trenches complete all as specified and as directed by Engineer-in-Charge.

20

-

-

... More
Supply and fix in replacement of air flow meter of suitable size of pipe complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
M & L for grass cutting with the help of Petrol Grass cutting machine all around the water supply installation of Brookshbad,Ajay baugh area and pereira enclave area complete all as specified and directed by Engineer-in-Charge Note: 1.The grass cutting machine shall be provided by the Contractor. 2. The rate is deemed to include cost towards tools, fuel and transportation required for attending the vegetation work.

54

-

-

... More
Taking down old unsv GI water tubing with all fittings, laid in trenches/fixed on wall/on roof etc of the folloing sizes :-

-

-

-

... More
20mm dia

10

-

-

... More
25mm dia

12

-

-

... More
40mm dia

15

-

-

... More
50mm dia

20

-

-

... More
S&F GI tubes medium grade ISI marked galvanized with all fittings, laid in trenches/fixed on wall/on roof etc of the following sizes :- Notes ; Excavation and earthwork required shall deemed to be included in this quoted rate.

-

-

-

... More
20mm dia

10

-

-

... More
25mm dia

12

-

-

... More
40mm dia

15

-

-

... More
50mm dia

20

-

-

... More
Supply and fixing in replacement Gun Metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge :-

-

-

-

... More
20 mm bore

2

-

-

... More
25 mm bore

2

-

-

... More
40mm bore

2

-

-

... More
50 mm bore

2

-

-

... More
Supply and fix in repair brass impact automatic rotating water sprinkler with nozzle heavy duty irrigation head (20 mm or 3/4 inch) all as specified and directed by Engineer-in-Charge.

9

-

-

... More
M&L for disconnecting and removing the unserviceable burnt out over load relays of switching current of 5A, 240V AC and coil voltage 28V DC of capacity from position and replacing the same with new over load relays including connecting and testing complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
M&L for painting of monoblock pump set/centrifugal pump sets/air blower including induction motor of any capacity with one coat of synthetic enamel paint by using spray gun machine after removing all dust and rust and writing date of painting with black synthetic enamel paint complete all as directed by Engineer-in-Charge.

16

-

-

... More
Taking out unserviceable LED type indicator lamp unit from the panel boards and supply and fix new LED type indicator lamp unit of red/ yellow/ blue/ green with bulb complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
Supply only 2mm thick rubber mat 2metre long and 1metre width for installation as directed by Engineer-in-Charge.

1

-

-

... More
M&L for disconnecting and removing unserviceable star coupling assembly set from the pump motor and drive system, supply and fixing new star coupling set of sizes 100/110/ 150/226 with nuts, bolts including making alignment and testing complete all as directed by Engineer-in-Charge

2

-

-

... More
Supply and fix in repairs gland packing with Graphite Gland Rope of size 10mm complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
Supply oil suitable for dosing pump and pumpset/compressor as per sample all as specified and as directed by Engineer-in-Charge

5

-

-

... More
S&F in replacement of pressure switch of pump set all as specified and as directed by Engineer-in-Charge

2

-

-

... More
S&F in repairs pneumatic solenoid valve as per sample for STP complete all as specified and as directed by Engineer-in-Charge

2

-

-

... More
S&F in repairs foot valve as per sample for STP complete all as specified and as directed by Engineer-in-Charge

1

-

-

... More
Supply only flexible PVC hose 25mm dia complete all as specified and directed by Engineer-in-Charge

60

-

-

... More
S & F Single Phase Preventor (SPP) Suitable for submersible/pump set starter complete all as specified and directed by Engineer-in-Charge .

1

-

-

... More
M&L for painting of pipeline/shed truss of various size connected at 200/125/50 KLD STP complete all as specified and directed by Engineer-in-Charge.

60

-

-

... More
M&L for disconnecting and removing the unserviceable DOL starter and supply, install testing and commissioning of DOL starter for the motors for the capacity of 7.5 HP, 415 Volts in sheet steel encloser including dismantling existing old motor starter from its location by removing all cable connections complete all as specified and as directed by Engineer-in-Charge. Make: L & T MK 01DOL or eqvalent in BCH

1

-

-

... More
All as per item No. 187.00 here in before but 3 - 5 HP complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
Material and labour for repair/servicing the existing LT panel at various locations of STP plant opening the front and back doors cleaning the inside compartments, opening the busbar chamber covers, replacing worn out inter connections, with suitable size of cables, replacing the rusted bolt nut washers, tightening the complete bolt nuts, earth connections etc, refixing the covers also providing 2 Nos of new LT danger notice board stickers complete all as specified and as directed by Engineer in Charge.

3

-

-

... More
Material and labour for preparing external surfaces of LT panel /pump panel at various locations completely removing the all dust and dirt including rust and applying one coat of approved existing shade of synthetic enamel painting including writing the required details as existing all as directed by Engineer-in-Charge.

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.