Military Engineer Services Tender

To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date4 Sep 2024
Closing Date4 Dec 2024
Tender Amount₹ 6,52,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lumpsum price worked out by the contractor for “PILE FOUNDATION” as listed in Schedule ‘A’ Part - III, inserted by MES.

1

-

12091098.72

... More
Lumpsum price worked out by the tenderer for "INTERNAL ELECTRIC SUPPLY" as listed in Schedule ‘A’ Part-IV, inserted by MES.

1

-

384633.17

... More
Lumpsum price worked out by the tenderer for "ROAD / PATH / CULVERT/HARD STANDING" as listed in Schedule ‘A’ Part- V, inserted by MES.

1

-

857312.12

... More
Lumpsum price worked out by the tenderer for "AREA DRAINAGE" as listed in Schedule ‘A’ Part- VI, inserted by MES.

1

-

260167.16

... More
Lumpsum price worked out by the tenderer for "EXTERNAL ELECTRIC SUPPLY " as listed in Schedule ‘A’ Part- VII, inserted by MES.

1

-

99185.9

... More
Lumpsum price worked out by the tenderer for "SOLAR STREET LIGHT" as listed in Schedule ‘A’ Part- VIII, inserted by MES.

1

-

265356.3

... More
Subtotal

-

-

-

... More
NOTE: Schedule ‘A’ Part - IX (miscellaneous) are not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.

-

-

-

... More
PILE FOUNDATION Drilling/boring through soft rock upto the depth as directed/indicated for 500mm outer dia bored cast-in-situ, vertical piles duly stabilising the sides by drilling fluids (reverse or DMC method) or by any other approved method and disposal of drilled/bored material to a distance exc 50m and n.exc 100m all as specified and shown on drawings.

391.03

-

-

... More
Drilling/boring through hard rock upto the depth as directed/indicated for 500mm outer dia bored cast-in-situ, vertical piles duly stabilising the sides by drilling fluids (reverse or DMC method) or by any other approved method and disposal of drilled/bored material to a distance exc 50m and n.exc 100m all as specified and shown on drawings.

392.03

-

-

... More
Carrying out/conducting of pile for initial load test all as per clause, 6.15 & 6.1.6 of IS-2911 Para IV-1985, for Axial load 48.394 Ton, lateral load 11.22 Ton and pull out load 22.12 Ton on designed safe load of 24.197 Ton 5.61 Ton and 11.06 Ton respectively on test pile of 500mm bore including bringing at site all testing equipment, making arrangement for testing and removed of the same after completion and recording the test result and preparing the test sheets complete all as specified and directed.

1

-

-

... More
Carrying out/conducting testing of pile of piles for routine load test all as per clause, 6.1.5 & 6.16 of IS-2911 IS-2911 Para IV-1985, for Axial load 36.30 Ton, lateral load 8.415 Ton and pull out load 16.59 Ton on designed safe load of 24.197 Ton 5.61 Ton and 11.06 Ton respectively on test pile of 500mm bore including bringing at site all testing equipment, making arrangement for testing and removed of the same after completion and recording the test result and preparing the test sheets complete all as specified and directed.

2

-

-

... More
Carrying out/conduction pile integrity test using low strain dynamic method all as per IS for 500mm dia piles complete all as specified and as directed.

84

-

-

... More
INTERNAL ELECTRIC SUPPLY M&L for earthing complete with copper earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below GL) with top edge of earth plate not less than 1.5 mtr below normal ground level, including provision of copper earth strip 25x4mm, earth plate surrounded from all sides by with 15cm thick packed layer of charcoal dust and common salt filling in alternate layer and electrode connection by using galvanized earth wire 4mm dia connected by mean of bolt, nut, chuck nut & washer of galvanized iron, provision of 20mm dia GI pipe medium grade for protection of GI strip & 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6), type C1 chamber, MS funnel, wire gauge, 50mm thick RCC 1:2:4 TMT bars on both ways including necessary excavation in any type of soil returning filling in removal of surplus soil to distance n.exc 50mtrs complete all as shown in electrical plate No 5 of schedule part I 2009 complete all as specified and directed.

2

-

-

... More
EXTERNAL ELECTRIC SUPPLY M&L for cable route indicator, consisting of cast iron round shape 200mm dia, 12mm thick with inscription casting as LT cable 1100 Volts grade and fixed with hot dipped GI angle iron of size 40mm x 40mm x 6mm thick 0.8 mtr long with GI nut bolts, embeded to ground in route of cable with the help of PCC 1:3:6 type C2 complete all as specified and directed.

4

-

-

... More
Supply and erect weather proof outdoor busbar chamber made out of CRCA sheet 3mm thick duly powder coated comprising of 4 Nos aluminium strips each of 100 Amps, 60cm long duly mounted on insulators including MCCB 63 Amp, 415V, 4 pole with 4 Nos mounting legs made out of 25mm x 25mm x 6mm angle iron grouted in PCC block of size 30cm x 30cm x 60cm in cement concrete 1:3:6 type C-2 (using 40mm grade crushed stone aggregate) connections with suitable size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points including excavation, returning, filling and removel of surplus soil. complete all as specified and directed.

1

-

-

... More
SOLAR STREET LIGHT Excavation in post holes n.exc .5 Cum for erection of poles, removing the excavated materials to distance n.exc 50mtr and providing PCC bed and RCC foundation as per following specification including form work (i) PCC BED - 450mm x 450mm x 100mm (ii) RCC column - 400mm x 400mm x 1300mm M20 Design, using 4 Nos - 12mm TMT rods and 7 Nos of 8mm dia TMT rods

6

-

-

... More
Subtotal

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.