To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date26 Jul 2024
Closing Date20 Sep 2024
Tender Amount₹ 25,00,000
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_666385_1Tender No
8144/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Dismantling fencing wire mesh, any type complete all as specified and as directed.
300
-
-
Excavating post holes or similar holes, each n.exc 0.5 Cum, getting out in soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm, watering, and removing surplus soil to a distance n.exc 50m & making good surface complete all as specified and as directed.
68
-
-
M & L for PCC (1:4:8) type D-2 (using 40 mm graded granite stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
10
-
-
M & L for mild steel round bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips confirming to Fe-410-W (Gde.E-250) quality-A or Fe 290 (Gde-E-165) complete all as specified and as directed.
241
-
-
S & F of flat iron fillets for securing wire mesh etc., including all necessary drilling holes for bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
60
-
-
S & F of PVC coated chain link fencing of mesh size 50 x 50 mm, 3 mm overall dia wire with 1.0 mm PVC coating fixed to any type of standards, rails, posts, straining bolts etc., complete all as specified and as directed.
300
-
-
M & L for MS screw bolts (machine made) 10mm to 12 mm dia with hexagonal or square head at one end screwed other or screwed end fitted with washers and one hexagonal or square not exc 125mm long with 3 mm thick one washer complete all as specified and as directed.
106
-
-
Demolition of precast concrete articles and precast concrete block walling built in cement mortar or cement lime mortar complete all as specified and as directed.
9
-
-
M & L for precast cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) block masonry with solid blocks, exc 10 cm in width and set in CM (1:4) complete all as specified and directed.
9
-
-
M & L for rendering 10 mm thick in CM (1:4) on fair faces of brick /block masonry or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
39
-
-
M & L for providing cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in coping, for hold fast, apex stone, bed plates water troughts and like including weathering slightly rounder or chamfered angles and throats complete all as specified and as directed.
0.5
-
-
M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
40
-
-
S & F for rolled mild steel framed work as in doors or gates of angle or other section confirming to Fe 410-W, with gusset plates, rails braces, etc., complete, drilled for fixing of steel sheeting or other covering and hanging and fixing complete all as specified and as directed.
300
-
-
M & L for preparation of new or previously treated surfaces of steel and iron surfaces n.exc 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
600
-
-
M & L for preparation of newly plastered surface of wall and finishing with acrylic smooth exterior paint of required shade (two or more coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/10 Sqm) complete all as specified and as directed.
39
-
-
E/M PORTION
S & F post top lantern LED type 35 watt, 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant with driver and lamp complete all as specified and as directed.
12
-
-
S & F bollard type LED type, 10 watt, 300 lumens, warm white, 230 volts AC outdoor type with decorative bollard light IP 65, Ik10 impact protection with impact and corrosion resistant with
driver and lamp complete all as specified and as directed.
28
-
-
S & F LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with driver and lamp complete all as specified and as directed.
6
-
-
S & F LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection including GI bend, clamps all misc accessories complete all as specified and as directed.
5
-
-
S & F bracket made out of GI tubing medium grade 40 mm bore , 90 cm long including MS clamps made out of MS flat iron 25 x 10 mm, nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer complete all as specified and as directed.
5
-
-
S & F steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) complete all as specifed and as directed.
2
-
-
Supply and lay GI tubing 50 mm dia, light grade for cable protection at road crossing / on poles and for stand post to hold post top lantern complete all as specified and as directed.
12
-
-
M & L for sub main wiring complete with 2 runs of 1.5 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor and drawing through conduit of suitable size and including provision of 1 run of 1.5 Sqmm insulated copper cable for earth continuity conductor and connecting to earth dolly complete from PVC Junction box to street light fittings / Post Top fittings all as specified and as directed by Engr-in-Charge.
Note : (i) 3 Runs of 1.5 Sqmm cable shall be measured as one unit length. (ii) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.
64
-
-
S & F of PVC junction box (For Bollards fittings) of size 140 x 140 x 95 mm, light weight pole mounting hinged type including necessary clamp for MCB mounting and mounting of box on pole/pipe with MS flat frame arrangement and necessary connector for looping in and looping out cable connection and suitable glands complete all as specified and as directed.
28
-
-
S & F of PVC junction box ( For street light pole and flood light of size 270 x 225 x 135 mm, light weight pole mounting hinged type including necessary clamp for MCB mounting and mounting of box on pole/ pipe with MS flat frame arrangement and necessary connector for looping in and looping out cable connection and suitable glands complete all as specified and as directed.
5
-
-
Supply and laying PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) for coping of poles complete all as specified and as directed.
0.94
-
-
Supply and laying PCC (1:2:4) type B-2 (using 40mm graded stone aggregate) for foundation of poles complete all as specified and as directed.
1.08
-
-
Supply, testing, laying & commissioning of XLPE insulated, armoured (heavy duty) electric cable with aluminium stranded conductor, 1100 volts grade, 2 core 6 Sqmm laid in trenches / duct / fixed to wall with suitable size clamps / passing through pipe / tunnel/ under ground /surface up to the termination point (as directed by Engr-in-Charge) and cable end terminations crimped with suitable size cable lugs, cable glands with tool, nuts, bolts etc and connecting end terminations to DBs/LT panel/ Busbar etc complete all as specified and directed by Engr-in-Charge.
145
-
-
Supply, testing, laying & commissioning of XLPE insulated, armoured (heavy duty) electric cable with aluminium stranded conductor, 1100 volts grade, 2 core 10 Sqmm laid in trenches / duct/ fixed to wall with suitable size clamps / passing through pipe/Tunnel/under ground /surface up to the termination point (as directed by Engr-in-Charge) and cable end terminations crimped with suitable size cable lugs, cable glands with tool, nuts, bolts etc and connecting end terminations to DBs/LT panel/Busbar etc complete all as specified and directed by Engr-in-Charge.
80
-
-
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth and getting out in hard/dense soil for foundation of poles, structures, stay rods, laying of underground cable etc complete all as specified and as directed.
68
-
-
Returning, filling in soils including spreading, leveling, watering and well ramming in layers each n.exc 25cm thick complete all as specified and as directed.
61
-
-
Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
7
-
-
S & F of HDPE double wall corrugated pipe confirming to IS -14930 part with IP protection IP-67 having outer dia 50 mm complete terminated up to termination end point complete all as specified and as directed.
202.5
-
-
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling for laying of cable pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
6
-
-
Supply, install testing and commissioning weather and vermin proof outdoor type L.T. Panel board (Near Galley) factory fabricated indoor cubicle/kiosk type totally enclosed IP 54 made out of 3.15 mm thick CRCA sheet metal enclosure of suitable size, with angle iron frame of M.S. angle 50 x 50 x 6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly spray painted grey hammer tone with one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour, including connecting with L.T. armoured incoming and outgoing cables and including required sizes of cable lugs of aluminum complete all as specified and directed and consisting of following :-
1
-
-
(a) Aluminium bus bar 400 Amps for 3 phase & neutral
(b) MCCB 4 pole 250 Amp 36 KA 415 V- 1 Nos (01 No. as Incoming)
(c) MCCB 4 pole 160 Amp 36 KA 415 V- 01 Nos. (As Outgoing)
(d) MCCB 4 pole 100 Amp 36 KA 415 V - 01 Nos. (01 No. as Outgoing)
(e) MCCB 4 Pole 63 Amps 16 KA 415 V - 01 Nos (01 No. as Outgoing)
(f) Digital Volt meter (0-500 V) with selector switch
(g) Digital Ammeter CT operated 0 to 500 Amp with phase selector switch
(h) Indicator lamp (RYB) - 3 Nos
(j) Blank Space for Mounting of MCCB - 01 No.
-
-
-
M & L for earthing with galvanised steel earth plate electrode 600 x 600 x 6mm burried earth pit not less than 2.25m depth below normal ground level with to edge of the plate vertically to depth of not less than 1.5 m below ground level connected to & including Galvanised earth strip of size 25 x 4 mm by mean of GI bolts & nuts etc with provision of char-coal and salt etc all as per electrical plate No-3 of SSR-2020 including RCC cover and MS angle iron frame, watering with GI pipe 20 mm dia (medium grade) & MS funnel, concrete pit including excavation and earthwork and testing on completion etc. complete all as specified and directed by Engr-in-Charge.
Note : (i) Earth work is deemed to be included in the Quoted Rate.
(ii) GI Strip as required at site is deemed to be included in the quoted rate.
(iii) On testing after completion, if the desired earth resistance is not obtained the earthing will be redone to the entire satisfaction of Engr-in-Charge at no extra cost
2
-
-
Supplying, laying or fixing, GI water tubing, medium grade, 80mm dia confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, etc laid in trenches / floors or fixed to walls / ceiling / roof etc including testing GI tubing with fittings / connections, in trenches / celiling /walls /roofs etc complete all as specified and as directed.
30
-
-
Description all as per Item No 40 above but 50mm dia complete all as specified and as directed.
250
-
-
Description all as per Item No 40 above but 40mm dia complete all as specified and as directed.
100
-
-
Description all as per Item No 40 above but 25mm dia complete all as specified and as directed.
80
-
-
Description all as per Item No 40 above but 20mm dia complete all as specified and as directed.
20
-
-
S & F 50mm dia Gun metal gate valve,with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
2
-
-
Description all as per Item No 41 above but 40mm dia complete all as specified and as directed.
3
-
-
Description all as per Item No 41 above but 25mm dia complete all as specified and as directed.
10
-
-
Description all as per Item No 41 above but 20mm dia complete all as specified and as directed.
8
-
-
M & L for addition alteration in old GI pipe, screwing, cutting, threading fixing of valve, attend the minor work regarding pipe line as per directed by Engr-in-Charge.
1
-
-
M & L for preparation of chamber of internal size 600mm x 600mm x 600mm including excavation, brickwork, plastering complete all as specified as directed.
2
-
-
Supply, install, testing and commisioning Hi-flow 1 HP monoblock pump of 25mm dia suction and discharge line having lifting height of 30m minimum to lift water from existing well along with proper PCC foundation and cover sheet made up of steel and Angle iron to protect from rain and one number foot valve all as specified and as directed.
2
-
-
Supply and laying flexible pipe of 25mm dia suitable for hi flow monoblock pump as required to lift water from well complete all as specified and as directed.
50
-
-
M & L for dewatering of RCC water reservoir /shallow wells (inside) of dia 25 m and depth upto 7m by using pumps complete all as specified and directed.
1
-
-
M & L for removing the sediments (silt) settled at the bottom of reservoir, scraping with the help of shovels, hard brushes and physical cleaning of reservoir / shallow well by de-scaling/ brooming silt and sludge and other deposits from inner side, collecting and taking them out with the help of manual labour and depositing at a distance not exceeding 50m complete all as specified and as directed.
22.6
-
-
M & L for washing RCC water reservoir/ shallow well properly with bleaching powder mixed with water (1:10) and applying two coats of anti fungal paint (white in colour) both internally and externally and writing the date of cleaning, and capacity of tank in paint (white letters on black back ground) including removing of any vegetation growth on the tank complete all as specified and as directed. Note for Item Nos 46.00 to 48.00:- (i) All necessary T & P, labours, materials and insurance of labour required for cleaning is deemed to be included in the quoted rate.
1
-
-