Military Engineer Services Tender

To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.

Military Engineer Services - MES Tender

Works
Civil And Construction
Electrical and Electronics
Pipe Line Project
Electrical Works
Eprocure
Opening Date25 Oct 2024
Closing Date14 Nov 2024
Tender Amount₹ 47,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fix 6kw ASTRONOMICAL timer panel Range Conforms to IS/IEC 60947-4-1, with 32amps contactor, 40amps MCB and Timer,Provided with Protection Degree IP 54,Extended wide band (150 Vac - 300 Vac) coil,FRLS (Fire retardant low smoke) Internal wiring,In-built Short-Circuit Protection, Class H Insulation complete all as specified and as directed.

2

-

-

... More
Supply, install, testing and commisioning of junction boxes, weather/vermin proof made out of 3.15mm thick CRCA sheet(CPRI approved) duly powder coated of size 60cm X 60cm x 60cm(depth), floor mounted free standing type, aluminium bus bar 200 Amps current carrying capacity for 3 Nos phase & neutral with colour coded heat shrinkable insulated sleeves and insulated support, mounting the junction box with PCC (1:3:6) type C1, bedding upto height of 30cm above ground level complete all as specified and directed.

4

-

-

... More
Material and Labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less thab 1.5 Meter below normal ground level connected to GI wire of dia 4mm as main earthing lead (upto 7.5 m length from earth electrode to test point) by means of galvanised iron or steel bolts, nuts, check nuts & GI washers and GI tubing 15 mm bore medium grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:2:4) type B1 as in cover slab 54 x 54 x 5 cm including 8mm dia MS TMT bars @ 150 mm c/c as in reinforcement with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (Light Grade) for watering and funnel, charcoal or coal and salt in alternate layers including excavation earth work in any type of soil, RFR and removal of surplus soil complete all as specified and directed electrical plate No. 3 of SSR part - I complete all as specified and as directed.

8

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core completed all as specied as directed.

1600

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core completed all as specied as directed.

1000

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil all as specified and as directed.

497.25

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in not exceeding 25 cm thick complete all as specified and as directed.

442.25

-

-

... More
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as directed.

55

-

-

... More
Supply and lay HDPE double wall corrugated pipes and including fittings such as couplers, bends, end caps etc., ISI marked of outer dia of 40mm and inner dia of 32mm polyethylene with smooth internal and profile external surface for non pressure under ground cable complete all as speciedd and as directed by Engineer-in-Charge.

2200

-

-

... More
Supply, laying and fixing 50mm bore GI light grade for necessary road crossing, culverts etc for cable protection all as specified and as directed.

24

-

-

... More
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundations of pole/ stay assembly complete all as specified and directed by Engineer-in-Charge.

26

-

-

... More
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping of pole including necessary form work complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
Taking down old Light fitting with Bracket and Arm complete all as specied and as directed.

85

-

-

... More
Fixing only using taken down old Serviceable LED lights on Existing Poles of any height complete all as specied and as directed.

20

-

-

... More
M & L for Demolition the old Existing RCC poles complete with PCC foundation andremoval of all debiries including old Pole from existing location complete all as directed.

85

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.