Military Engineer Services Tender

To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date19 Jan 2024
Closing DateCancelled
Tender Amount₹ 41,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Demolition of Cement Concrete(unreinforced) including tiles and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
Taking up or down old/chocked water tubings 20mm bore with fittings from trenches /walls and credit to contractor all as directed by Engineer-in-Charge. (Note :- The quoted rate shall deemed to be inclusive of scaffolding at any height )

60

-

-

... More
Taking up or down old/chocked water tubings 25 or 32 mm bore with fittings from trenches /walls and credit to contractor all as directed by Engineer-in-Charge. (Note :- The quoted rate shall deemed to be inclusive of scaffolding at any height )

195

-

-

... More
Taking down existing chowkats or frames exc 1.5 sq. m but n exc 4 sq. m each without taking off shutters from the frames complete all as specified and directed by Engineer-in-Charge.

12

-

-

... More
Taking down existing chowkats or frames n.exc. 1.5 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the debris of the premises complete all as specified and directed by Engineer-in-Charge.

350

-

-

... More
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed by Engineer-in-Charge. (Note :- The quoted rate shall deemed to be inclusive of scaffolding at any height )

20

-

-

... More
S& F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed by Engineer-in-Charge. (Note :- The quoted rate shall deemed to be inclusive of scaffolding at any height )

110

-

-

... More
S& F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed by Engineer-in-Charge. (Note :- The quoted rate shall deemed to be inclusive of scaffolding at any height )

40

-

-

... More
Supply & fixing aluminium Flat iron work in wind ties scrow as directed incl all necessary drilling ,bolting , riviting & etc complete all as specified and directed by Engineer-in-Charge. (Note :- The quoted rate shall deemed to be inclusive of scaffolding at any height )

50

-

-

... More
S&F PVC (SWR) 110 mm dia pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or on wall complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
S&F PVC (SWR) 75 mm dia pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or on wall complete all as specified and directed by Engineer-in-Charge.

40

-

-

... More
S&F in PVC (SWR) bends 110 mm dia etc complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
S&F in PVC (SWR) bends 75 mm dia etc complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
Material and Labour for external rendering 5mm thick in cement mortar 1:4 with water proofing compound (water proofing compound shall be used as per manufacturers instructions) over a coat of 10mm thick in cement mortar 1:6 over block masonry or concrete surfaces finished even and fair complete all as specified and directed by Engr-in-Charge. Note : Water Proofing Compound shall be measured and paid separately as 'Supply only'

435

-

-

... More
M&L for rendering 10 mm thick on fair faces of brick/concrete surface in CM (1:6) finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.

150

-

-

... More
M&L for rendering to ceiling in 5 mm thick on fair faces concrete surface in CM (1:3) finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
Supply only water proofing compound conforming to IS-2645 1975 complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
M & L for preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed by Engr-in-Charge

150

-

-

... More
M&L for preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed by Engr-in-Charge.

100

-

-

... More
M & L for preparation of new surface and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed by Engr-in-Charge. (Note :- The quoted rate shall deemed to be inclusive of scaffolding at any height )

435

-

-

... More
S & F Aluminium anodised (minimum anodisation is 50 microns) Door / window / Ventilator/partition frames and shutters (02 Nos glazed & gauzed), side hung type, without sash bars, standard aluminium grills, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangements etc including fixing of glass, wire mesh, particle boards etc complete with standard aluminium sections, complete all as specified and as directed by Engineer-in-charge. Note - (i) Weight of necessary Aluminium alloy handles and locking arrangements shall be considered for measurement and payment under this unit rate. However cost of rubber packing given in the item shall be deemed to be included in the rate quoted. (ii) Glass panels, prelaminated particle boards, glass & aluminium wire cloth as applicable shall be measured and paid separately as suppy only under relevent item of this schedule

300

-

-

... More
Supply only 5mm thick sheet figured glass and glazing with rubber packing around the glass, in squares exceeding 0.50 sqm in each pane complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
S& F in repairs 5mm thick sheet figured glass and glazing with rubber packing around the glass, in squares exceeding 0.50 sqm in each pane complete all as specified and directed by Engineer-in-Charge.

35

-

-

... More
Supply only aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
Supply & fix in repairs aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed by Engineer-in-Charge.

60

-

-

... More
S&F in repairs only stainless steel friction stay hinges 200 x19 x1.90 mm of standard size complete all as specified and directed by Engineer-in-Charge.

70

-

-

... More
M&L for preparing new or previously untreated surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. (Note :- The quoted rate shall deemed to be inclusive of scaffolding at any height )

50

-

-

... More
M&L complete removal existing treatment on wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant priming paint including preparation of new plastered surfaces of wall complete all as specified and directed by Engineer - in -Charge.

1960

-

-

... More
M & L for preparation of old plastered wall surfaces and applying one coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/liter and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 liter/ 10 sqm complete all as specified and as directed by Engr-in-Charge. (Note :- The quoted rate shall deemed to be inclusive of scaffolding at any height )

1160

-

-

... More
M&L For Mild steel framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary gusset plates, riveting, etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and directed by Engineer-in-Charge. Note : Brackets over 10 kg each to be measured under 'Structural Steel'

800

-

-

... More
S&F for Stairs (framed) including stringers, treades, landing balusters, hand rails etc. including cleats, brackets, etc Fe-410- W(Gde- E-250) quality- A complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
S&F for Rolled sections/Tubular MS pipes as in cross beams, hip and jack rafters, vertical posts, purlins where connected to common rafters fixed with angle cleats or similar work including welding and all necessery works complete all as specified (Fe 410-W -(Gde E-250) quality A (Note :- The quoted rate shall deemed to be inclusive of scaffolding at any height )

1000

-

-

... More
S & F Mild steel screw bolts (machine made) of any dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n.exc. 10 cm long complete all as specified and as directed

20

-

-

... More
S&F Plates (Plain or chequred), channels, square cut or notched forming holes, without any attachment incl necessary welding complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
M & L for Filleting not exc 25 Sqcm in any position and to any shape in cement mortar 1:4 including all mitres, stops complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting exc 10 cm but not exc 20 cm girth complete all as specified and directed by Engineer-in-Charge.

75

-

-

... More
S&F 10 mm dia 100 mm long dash through fasteners bolt in concrete and brick work complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed CM 1:6 complete all as specified and directed by Engineer-in-Charge.

50

-

-

... More
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed CM 1:6 complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
All asper Item No.43.00 above but skirting / dado fixed with 10 mm thick backing cement coat C:M 1:4 complete all as specified and directed by Engineer-in-Charge.

25

-

-

... More
M&L glazed ceramic coloured tiles 450mm x 300mm x 6 to 7mm thick on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick bedding layer in cement mortar (1:3) including necessary cutting as per site requirement complete all as specified and directed by Engineer-in-Charge.

75

-

-

... More
S&F of CPVC Pipes SDR 11 & plain CPVC SDR 11 fittings on walls / ceiling or laying in floor complete all as specified and directed by Engineer-in-Charge.

-

-

-

... More
32 mm dia

75

-

-

... More
25 mm dia

120

-

-

... More
S&F Brass Elbow CPVC pipe outer dia 32 mm complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F Brass Elbow CPVC pipe outer dia 25 mm complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F Brass Tee CPVC pipe outer dia 32 mm complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F Brass Tee CPVC pipe outer dia 25 mm complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F Male brass threaded adopter CPVC pipe outer dia 32 mm complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F Male brass threaded adopter CPVC pipe outer dia 25 mm complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F Tank adopter CPVC pipe outer dia 32 mm complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F Tank adopter CPVC pipe outer dia 25 mm complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F Union CPVC pipe outer dia 32 mm complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F Union CPVC pipe outer dia 25 mm complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&Fball valve CPVC pipe outer dia 32 mm complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
S&F ball valve CPVC pipe outer dia 25 mm complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
S&F 20 mm PPR Gate valve (brass insert ) as per the requirment complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F 25 mm PPR Gate valve (brass insert) as per the requirment complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F in repair Chromium Plated towel rail 20 mm dia, 60 cm long fixed with CP screws and wood cleats / rowel plug in wall, complete all as specified and directed by Engineer-in-Charge.

12

-

-

... More
S&F in repair looking mirror of selected quality glass 600 mm wide, 5 mm thick on 6 mm thick, BWP commercial ply wood backing and placed in aluminium frame / wooden frame complete all as specified and directed by Engineer-in-Charge. Note:- Aluminium frame / wooden frame shall be measured and paid separately

10

-

-

... More
S & F in repair Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type heavy duty, 15 mm dia, with capstan head, screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.

16

-

-

... More
S & F in repairs to Bib Taps, cast copper alloy heavy duty, 15 mm dia, Chromium Plated, Fancy Type screwed down for iron pipe and fixed etc complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
S & F in repairs 15 mm dia bore cast copper alloy chromium plated angle cock/stop cock with long shank and cup screwed down high pressure with capstan head, screwed both ends for iron pipes or for union and fixed, complete all as specified and directed by Engineer-in-Charge.

38

-

-

... More
S & F in repairs to Two way Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type screwed down for iron pipe and fixed etc complete all as specified and directed by Engineer-in-Charge.

16

-

-

... More
S & F in repairs 32/40mm dia PVC flexible Waste Pipe, 750 mm long fixed to Wash Hand Basin or Sink complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
S&F in repairs PVC connection 15mm size with CP brass Nuts of legnth 600 mm complete all as specified and as directed by Engineer-in-Charge

35

-

-

... More
S&F in repairs 32mm concealed flush valve female ( hydropole valve ) complete all as specified and directed by Engineer-in-Charge.

16

-

-

... More
S & F in repair Vitreous China Counter top Wash hand basin of white colour of size 520mm x 440m x 180mm including fixing on granite slab,including 15mm chromium plated Pillar Tap cast copper alloy with capstan heads long shank, 32 mm waste coupling brass chromium plated suitable for wash hand basins, with long screwed shanks and fly nuts including 15mm PVC connection pipe of length 600mm length complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
M&L precast cement concrete block masonry with PCC solid blocks in 1:3:6 type C1 using 20mm graded stone aggregates, exc. 10cm in width and set in CM 1:4 complete all as specified and directed by Engineer-in-Charge.

3.5

-

-

... More
M&L for 75mm thick Plain Cement Concrete 1:3:6 type C1 using 20mm graded stone aggregate as in plinth protection and finished even and smooth with using extra cement laid in panels with dummy joints including formwork complete all as specified and directed by Engineer-in-Charge.

55

-

-

... More
S&F 18 to 20 mm thick MDF board incuding 0.9mm decorative laminations on bothsides , one side plain and another side decorative fixed to frame work including adhesives, accessories etc complete all as specified and directed by Engineer-in-Charge.

35

-

-

... More
M&L for First class hard wood for wooden beading , cupboards / shelves / wardrobe / wall panelling exc 6 ¬ exc 13 Sqm complete all as specified and directed by Engineer-in-Charge.

35

-

-

... More
S&F 100 mm brass handles , cast type , polished bright complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
S&F 100 mm size hasp and staple , safety type , brass with mild steel hinges pin incuding bolt to hinge plate with scrows complete all as specified and directed by Engineer-in-Charge.

12

-

-

... More
S&F continuous (piano) hinges , mild steel , bright finish or electro galvanished and width of flaps 30 mm (when open ) complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
S&F Teak wood lipping frame 6 mm thick for 18/ 19 mm width fixed with nails/ screws complete all as specified and directed by Engineer-in-Charge.

35

-

-

... More
S&F Second class hard wood for plain , solid , straight , chowkats and frames , wrought , framed reabeated the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed by Engineer-in-Charge.

0.02

-

-

... More
S&F Magnet catch for cup boards of brass body and skirting plate complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
Material and labour APP modified waterproofing treatment over existing RCC roof slab with following specification including brushing off the surface to receive the treatment obtain the required surface and then providing 10mm screed bed in CM 1:3 with water proofing compound with required slope complete all as specified and directed by Engineer-in-Charge. :- (a) Applying bituminous primer @ 1.2 kg/Sqm on the prepared dry roof surface. (b) Laying 4mm thick APP membrane Plain finish weight not less than 3 to 4 kg per sqm by torch application with minimum 10cm side lap and 15cm end lap.(c) Applying bituminous primer @ 1.2 kg/Sqm and applying one coat of bituminous aluminium paint at the rate of 0.3kg/sqm Note : The laying of membrane shall be got done through an authorized applicator of manufacturer of APP membrane.

200

-

-

... More
M&L for 40mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) for correction of roof slab / roof padding etc including formwork complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
M & L for taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, ceiling roses, pendants, regulators sockets etc, removing materials and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer-in-Charge.

122

-

-

... More
M & L point wiring with 1.5 Sq.mm (nominal area) pvc unsheathed multi strandard copper conductor pvc insulated 1100 volt FRLSH grade multistranded cable drawn through and including PVC casing capping/conduit ISI marked minimum 20mm size and its accessories complete along with 1.5 Sqmm cable but in green colour as continuous earthing wire and connecting to common earth dolly completely concealed ,surface, in walls/ceiling/roofs with and including 1.2 mm thick MS sheet terminal boxes duly fabricated flush mounting in the wall for mounting switches, switch socket combinations fan regulators etc., as required with 3 mm thick plastic laminated sheet top cover complete all as specified and directed by Engineer-in-Charge for the following:-

-

-

-

... More
One light /fan/bell point controlled by one 05Amps switch complete all as specified and directed by Engineer-in-Charge.

76

-

-

... More
One 5 Amps plug point independent board controlled by one switch complete all as specified and directed by Engineer-in-Charge.

11

-

-

... More
One three pin switch socket 5 Amps plug point on same board complete all as specified and directed by Engineer-in-Charge.

24

-

-

... More
All as per item No.87.00 above but with 2.5 Sqmm single core multi standard copper conductor for one three pin socket 5 Amps on independent board including continuous earth wire PVC insulated 2.5sqmm copper solid conductor to common earth dolly complete all as specified and directed by Engineer-in-Charge.

9

-

-

... More
Supply and fix Socket, 16amps - 2/3 pin combined ,220V 50Hz complete all as specified and directed by Engineer-in-Charge.

9

-

-

... More
Supply and fix switch 1way 16 Amps, 220V 50Hz 1module complete all as specified and directed by Engineer-in-Charge.

9

-

-

... More
All as per item No.87.00 above but 4.00 Sqmm single core multi standard copper conductor for one three pin socket 5 Amps on independent board including continuous earth wire PVC insulated 2.5 Sqmm copper solid conductor to common earth dolly complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F socket outlet 2/3 pin 5 Amps 240 volts flush type complete all as specified and directed by Engineer-in-Charge.

35

-

-

... More
S&F Piano switches 6 Amps 240 volts flush type complete all as specified and directed by Engineer-in-Charge.

111

-

-

... More
supply and fix Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
S&F ceiling rose, surface bakelite 65 mm x 30 mm, 3 terminals complete all as specified and directed by Engineer-in-Charge.

76

-

-

... More
Supply and fix in replacement of LED tube light fitting, 1x20 w, 230v .Surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver.Flicker free, high efficiency and robust industrial batten family suitable for Surface, Wall and Conduit mounting. The product family offers dimmable and connected batten option & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.

42

-

-

... More
Supply and fix LED lamp 9W 220V 50HZ complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
Supply and fixing in repair LED bldg light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
Supply and fixing BLDC ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor complete all as specified and directed by Engineer-in-Charge. NOTE : Old retrieved wall fan shall de deposited in E&M store yard.

12

-

-

... More
S&F single phase, 230 volts, 50 Hz, wall mounted fan, 450 mm sweep fixed on wall with fan clamp/hook, connecting electrically all as specified and directed by Engineer-in-Charge. NOTE : Old retrieved wall fan shall de deposited in E&M store yard.

5

-

-

... More
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed by Engineer-in-Charge. NOTE : Old retrieved wall fan shall de deposited in E&M store yard.

8

-

-

... More
S&F in replacement of MCB TPN 63 Amps working on 415 volts 50 Hz AC supply,10 KA C series including taking out old one complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F in replacement of MCB TP 32 Amps working on 415 volts 50 Hz AC supply,10 KA C series including taking out old one complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
S&F in replacement Distribution Board TPN 12 way double door with category of protection double door type IP-42 factory made with tinned copper bus bar suitable for MCBs complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
S&F in replacement of Distribution Board SPN 8 way with category of protection double door type IP-42 factory made with tinned copper 200 Amps rated bus bar suitable for MCBs,complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
S&F in replacement of MCB SPN 32 Amps working on 415 volts 50 Hz AC supply,10 KA C series including taking out old one complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
Supply and fix in replacement of MCB single pole 5 to 32 Amps working on 240 volts 50 Hz AC supply,10 KA C series complete all as specified and directed by Engineer-in-Charge.

36

-

-

... More
Taking down carefully copper/aluminium Sub main wiring of size 1.5/ 2.5/ 4 / 6/ 10/16/25 Sqmm from surface/concealed /existing conduit of any height removing unserveciable materials at site and disturbed surface to match with existing finish with plaster and applying white / colour wash / OBD / cement based paint as per existing at site as required of walls, floors roofs etc complete all as specified and as directed by Engineer-in-charge.

330

-

-

... More
M&L for Sub main wiring complete with 2x6 sqmm , single core , multi stranded copper conductor FRLSH PVC insulated and sheathed cable 1100 Volts grade , drawn in PVC Casing Capping in surface /PVC conduit in concealed/surface (as required) along walls roofs etc including 6 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge. Note:- all three wire/cable(phase, neutral and earth) should be run through for each individual circuit from the DBs. Note. Two run of cable and earth conductor be measured as one length)

150

-

-

... More
M&L for Sub main wiring complete with 2x4 sqmm , single core , multi stranded copper conductor FRLSH PVC insulated and sheathed cable 1100 Volts grade , drawn in PVC Casing Capping in surface /PVC conduit in concealed/surface (as required) along walls roofs etc including 4 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge. Note:- (All three wire/cable(phase, neutral and earth) should be run through for each individual circuit from the DBs. Two runs of cable and earth conductor be measured as one length)

100

-

-

... More
M&L for Sub main wiring complete with 2x2.5 sqmm , single core , multi stranded copper conductor FRLSH PVC insulated and sheathed cable 1100 Volts grade , drawn in PVC Casing Capping in surface /PVC conduit in concealed/surface (as required) along walls roofs etc including 4 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge. Note:- all three wire/cable(passé, neutral and earth) should be run through for each individual circuit from the DBs. Note. Two run of cable and earth conductor be measured as one length.

80

-

-

... More
Supply and laying testing and commissioning in repair XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq.mm 3.5 core all as specified and as directed by Engr in charge.

35

-

-

... More
Supply & laying in replacement DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polyethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure for under ground cable complete all as specified and directed by Engr-in-Charge Note : if the cable is laid in trenches, excavation, returning filling and removal of surplus soil shall be measured and paid separately under relevant item of this Schedule.

30

-

-

... More
Excavation in trenches, not exceeding 1.50m wide and not exeeding 1.50m in depth for foundations, trenches of cable or pipe lines etc or and getting out in soft / loose soil complete all as specified and directed by Engineer-in-Charge.

516.3

-

-

... More
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-Charge.

50.24

-

-

... More
Removing excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all as specified and directed by Engineer-in-Charge.

12.17

-

-

... More
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized earth strip of 25x4mm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel and connected from earth plate electrode to main switch board/ earthing test point including watering arrangement with 20 mm GI pipe medium grade,40 mm GI pipe light grade for earth strip protection, PCC 1:3:6 type C1 chamber, MS funnel, wire gauge, 50mm thick precast RCC cover in Type B1, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n.exc 50m, charcoal and salt complete all as shown in electrical plate No. 3 of Schedule Part-I 2009 and connected to earthing test point all as specified or indicated and testing on completion complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
Supplying, laying GI water tubing, medium grade, of 50mm bore confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, etc laid in tenches / floors or fixed to walls / ceiling / roof etc including testing etc complete all as specified and directed by Engr-in-Charge

310

-

-

... More
Supplying, laying GI water tubing, medium grade, of 25mm bore confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, etc laid in tenches / floors or fixed to walls / ceiling / roof etc including testing etc complete all as specified and directed by Engr-in-Charge.

150

-

-

... More
Supply and fix Gun Metal, globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed of 50mm bore complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fix Gun Metal, globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed of 25mm bore complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
S&F in replacement ball valves high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball screwed for iron pipe and fixed ( Minimum weight 20mm - 210gms / 25mm - 455 gm) of 25mm size complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
Excavating in trenches in soft/loose soil, n exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for shafts, wells, cessapits, manholes, pier holes, etc n exc 10 Sqm on plan and getting out complete all as specified and directed by Engr-in-Charge.

5.1

-

-

... More
S&F Rotational moulded polyetheylene (HDPE) 1000 liter ISI marked Water Tanks, Cylindrical & Vertical Type, double layered,with 25mm bore tank nipple, ISI marked, hoisted and fixed in position including provision of 40mm / 25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
S&F Rotational moulded polyetheylene (HDPE) 2000 liter ISI marked Water Tanks, Cylindrical & Vertical Type, double layered,with 25mm bore tank nipple, ISI marked, hoisted and fixed in position including provision of 40mm / 25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Material and labour for cutting existing GI/DI pipe line of 50/80mm bore and making connection of 25 mm bore GI pipe complete all as specified and directed by Engr-in-Charge. Note : Earth work shall deemed to be inclusive in this quoted rate.

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.