Military Engineer Services Tender
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Military Engineer Services - MES Tender
Security and Emergency Services
Electrical and Electronics
Electrical Works
Eprocure
Opening Date2 May 2024
Closing Date28 May 2024
Tender Amount₹ 40,50,000
Costs
EMD
₹ 81,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_641722_3Bid Award Id
ViewTender No
8370/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M & L Hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
17.5
-
-
M&L for Plain Cement Concrete type D2 1:4:8 using 40mm graded aggregate in foundation, filling and mass concrete including formwork complete all as specified and directed by Engineer-in-Charge.
2
-
-
M&L Precast Cement Concrete block masonry with solid block, exc 10cm in width in PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:4) complete all as specified and directed by Engineer-in-Charge.
17
-
-
M & L for rendering 5 mm thick in cement mortar 1:4 over a backing coat of 10mm thick in CM 1:6 (Total 15 mm thick) on concrete or brick masonry surfaces including mixing water proofing compound as per manufacurers instructions and finishing the top surface even and fair complete all as specified and directed by Engineer-in-Charge.
Note: Water proofing compound will be measured and paid separately.
80
-
-
M & L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engineer-in-Charge.
80
-
-
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
45
-
-
S&F Mild steel works as in small articles such as hold fast of flat iron bent to shape making holes etc complete all as specified and directed by Engineer-in-Charge.
10
-
-
M&L Mild steel Roof trusses (framed), trusssed, purlings, crane gantries, rails and fasternings and heavy breacket frasming (Beam, tee, angle, Channel, hollow sec or flat sections) including distance pieces, cleates, gusset paltes etc Fe 410-w grade E-250 quality A complete all as specified and directed by Engineer-in-Charge.
300
-
-
M&L for preparation of new steel surfaces over 10cm width or grith and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
40
-
-
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as in ridges, hips, valley gutter, drip, and straight flashing complete all as specified and directed by Engineer-in-Charge.
30
-
-
Supply, install, testing and commissioning of HSD fuel digital flow meter with flow range 1000 to 50000LPH suitable for 3" BSP with NPN open collector type pulse, made out of Aluminium body with aluminium rotor, NBR O ring, BSP thread female, cable etc complete including necessary addition/ alteration to 100 mm dia MS pipe with reducers etc complete including dismantling old defective conventional scale type meter complete all as specified and directed by Engineer-in-Charge.
Make: Fluido Sense Pvt Ltd or equivalent make approved by HQ CE Southern command or GE confirming relevant IS provisions.
1
-
-
Supply, install, testing and commissioning of HSD fuel digital flow meter with flow range 200 to 4000LPH suitable for 1" BSP with NPN open collector type pulse, made out of Aluminium body with aluminium rotor, NBR O ring, BSP thread female, cable etc complete including necessary addition/ alteration to 25 mm dia MS pipe with necessary fittings etc complete including dismantling old defective conventional scale type meter all as directed by Engineer-in-charge. Make: Fluido Sense Pvt Ltd or equivalent make approved by HQ CE Southern command or GE confirming relevant IS provisions.
1
-
-
Supply, install, testing and commissioning of HSD fuel digital flow meter with flow range 600 to 20000LPH suitable for 2" BSP with NPN open collector type pulse, made out of Aluminium body with aluminium rotor, NBR O ring, BSP thread female, cable etc complete including necessary addition/ alteration to 50 mm dia MS pipe with necessary fittings etc complete including dismantling old defective conventional scale type all as directed by Engineer-in-charge. Make: Fluido Sense Pvt Ltd or equivalent
1
-
-
Supply, install, testing and commissioning of HSD fuel digital FLOW TOTALIZER of size 96x96 mm panel, suitable for operation on 230 V AC supply, with pulse 4 to 20mA, RS-485, relay (2Nos) mounted in CRCA enclosure IP 54 panel complete including necessary cabling, wiring, errection etc complete including dismantling old defective conventional type all as directed by Engineer-in-charge. Make: Fluido Sense Pvt Ltd or equivalent
3
-
-
Supply, install, testing and commissioning of HSD fuel consumption system for diesel engine of following capacities consisting of digital flow meters 2Nos with flow range 50 to 1200LPH suitable for 1/2" BSP made out of Aluminium body with aluminium rotor, NBR O ring, BSP thread female, cable etc complete including necessary addition/ alteration to 1/2 inch dia pipe with necessary fittings etc complete and fuel consumption calculator -1 Nos suitable for operation on 230 V AC supply with RS-485 Modbus communication & USB of size 96x96 mm mounted in sheet metal enclosure 54 including necessary wiring etc complete including dismantling old defective conventional type all as directed by Engineer-in-charge. Make: Fluido Sense Pvt Ltd or equivalent Note : (i) The quoted rate inclusive for carrying out testing of DG set by testing Officer nominated by HQ CE A&N Zone through AO . The cost of POL required for testing the DG Set is deemed to be included in quoted rates. The DG Set shall run for a period of 12 Hours continuosly with existing connected load with ratio of loading maximum upto 75% loading or as per requirement at Site and as directed by testing Officer and GE/Engineer-in-Charge.
-
-
-
For 750 KVA DG sets
3
-
-
For 650 KVA DG set
1
-
-
Supply, install, testing and commissioning of batch controller (dispensor type) with input pulse, relay 4-20mA, RS-485 Communication suitable for operation on 230 V AC power supply and 4" touch screen display complete mounted in steel sheet enclosure including dismantling old defective conventional type all as directed by Engineer-in-charge.
1
-
-
Supply.install, testing and commissioning of 4G/5G gateway, 4 channel, 4G/5G IoT gateway for online data monitoring with SIM card and data charges for minimum 2 years complete all as specified and directed by Engineer-in-Charge.
2
-
-
M&L for Cross arms, bracings, supports,clamps, MS pipes, MS sheets and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engineer-in-Charge.
2
-
-
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating of capacity 2.0 TR complete all as specified and as directed. (up to second floor) complete all as specified and directed by Engineer-in-Charge. Note:- (a) The cost of refrigerant gas, compressor oil, remote with batteries, tools & plants for fixing of outdoor unit at any height and making good disturbed surfaces is deemed to be included in the quoted rate. (b) Drilling of the wall should be done by core cutting machine.
3
-
-
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating of capacity 1.5 TR including required gas charging ( height upto second floor) complete all as specified and directed by Engineer-in-Charge. Note:- (a) The cost of refrigerant gas, compressor oil, remote with batteries, tools & plants for fixing of outdoor unit at any height and making good disturbed surfaces is deemed to be included in the quoted rate. (b) Drilling of the wall should be done by core cutting machine.
1
-
-
S&F Power unit modules 25A, 240V, 50HZ consists of 2 module surface mounting plastic box - 2 No, 2 module cover plate & frame - 2 No, 25Amps Motor Starter - 1 No , 25Amps socket - 01 No and 25 Amps Plug Top - 1 No complete all as specified and directed by Engineer-in-Charge.
4
-
-
M&L for Air conditioner mounting bracket heavy duty GI steel/MS, Powder coating finish inclusive of nuts and bolts for mounting the bracket on wall complete all as specified and directed by Engineer-in-Charge.
9
-
-
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 5.0 KVA complete all as specified and directed by Engineer-in-Charge.
4
-
-
Supply and fixing of Copper tubing of size 1/2" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and directed by Engineer-in-Charge.
20
-
-
Supply and fixing of Copper tubing of size 3/8" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and directed by Engineer-in-Charge.
20
-
-
Supply & fixing submain wiring with PVC insulated unsheathed multi-stranded copper conductor cable two run of 6 Sqmm single core (FRLSH) 1100 volts grade drawn through in and including PVC casing caping for surface wiring with casing & caping accessories laid on wall/ceiling and one run of 6 Sqmm PVC insulated copper conductor(FRLSH) for earth continuity wire complete all as specified and directed by Engineer-in-Charge. Note : Two run of single core cable with one run of earth continuity conductor and PVC casing 'n' caping and PVC casing & caping accessories will be measured as one length..
80
-
-
Supply and fixing Rigid non-metallic PVC conduit 25 mm dia inclusive of all fittings and fixing accessories complete all as specified and directed by Engineer-in-Charge.
57
-
-
Supply & fixing submain wiring with PVC insulated unsheathed multi-stranded copper conductor cable two run of 10 Sqmm single core (FRLSH) 1100 volts grade drawn through in and including PVC casing caping for surface wiring with casing & caping accessories laid on wall/ceiling and one run of 10 Sqmm PVC insulated copper conductor(FRLSH) for earth continuity wire complete all as specified and directed by Engineer-in-Charge. Note : Two run of single core cable with one run of earth continuity conductor and PVC casing & caping and PVC casing & caping accessories will be measured as one length.
26
-
-
Supply & fixing MCB Distribution Board SPN 8 way, double door, sheet metal enclosure, 240V, 100 amps rated busbar including fixing of cable with appropriate size of lugs complete all as specified and directed by Engineer-in-Charge. Note : Cost for concealed the DBs on wall including making good disturbed surfaces with existing colour shall be deemed to be included in the quoted rate.
1
-
-
Supply and fixing MCB SPN 40 to 63 Amps ,10 KA, C Curve, 230 Volts 50 HZ complete all as specified and directed by Engineer-in-Charge.
1
-
-
Supply and fixing MCB SP 6-32 Amps ,10 KA, 'C' Curve, 230 Volts, 50 HZ complete all as specified and directed by Engineer-in-Charge.
6
-
-
Supply, installation, configuration, testing and commissioning of Fire Alarm Control Panel, complete system with user interface, CPU, one loop with second loop expansion, three option card slot extendable upto six loops, four class B NAC, mother board, display board and power supply card with input voltage 94-265 volts AC supply & output voltage 24 V DC, optional ethernet interface for central station communication, email and dignostics & 1100 event history log complete all as specified and as directed by Engineer-in -charge.
Note:
(i) The quoted rate is inclusive for installation, testing & commissioning of FACP by the rep of OEM, 01No additional loop card for second loop expansion, mapping of locations with existing heat & smoke detectors as directed by Engineer in Charge.
(ii) The Fire Alarm panel shall be compatible to communicate with existing self addressable heat & smoke detectors.
1
-
-
Supply, installation, configuration, testing and commissioning of addressable active repeater panel which consists 168 character LCD display, control display modules, optional ethernet interface for communication and compatible for fire alarm control panel catered in Item No 37 complete all as specified and as directed by Engineer in Charge.
1
-
-
Supply, installation, testing and commissioning of 01 kVA, single phase online UPS with input voltage range110-300 Volts with output voltage 230 volts, THD 2% for linear load and 4% for non linear load with in built batteries and LCD display complete all as specified and as directed by Engineer in Charge.
1
-
-
M & L for submain wiring with two single core PVC insulated flexible copper conductor cable of size 4 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in and including surafce PVC casing capping and making good the disturbed wall surfaces to match with existing specification complete all as specified and as directed by Engineer-in -charge.
Note:
(a) Proper colour coding is to be followed as per IS Specification (b) Three runs of PVC insulated flexible copper conductor cable and one run of PVC casing capping shall be measured as 01 unit.
25
-
-
Supply & fixing IP 65 / 66 thermoplastic-polycarbonate cable junction box of size 130X180X77 with terminal suitable for 4 to 10 Sqmm which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on surface / frame with the help of required size / self drill screw and 01 No RCBO, Double pole 240 volts, 6 Amp with residual current limit upto 30 mA complete all as specified and as directed by Engineer-in -charge.
1
-
-
Supply and install vertical tower AC, indoor/outdoor complete with cordless remote control unit, twin rotary compressor, three phase units 415V, 50HZ of minimum 4 TR capacity or nearest higher capacity as per OEM design complete all as specified and directed by Engineer-in-Charge. Note:- (a) The cost of refrigerant gas, compressor oil, remote with batteries, tools & plants for fixing of outdoor unit at any height and making good disturbed surfaces is deemed to be included in the quoted rate. (b) Drilling of the wall should be done by core cutting machine.
5
-
-
Supply and fixing of Copper tubing of size 5/8" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and directed by Engineer-in-Charge.
20
-
-
Supply and fixing of Copper tubing of size 3/4" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and directed by Engineer-in-Charge.
20
-
-
S&F Sheet metal Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 415V, 32 Amp complete all as specified and directed by Engineer-in-Charge.
5
-
-
M&L for submain wiring with PVC insulated unsheathed multi-stranded copper conductor cable four run of 10 Sqmm single core (FRLSH) 1100 volts grade drawn through in and including concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing caping of suitable size and making good the disturbed wall surfaces to match with existing specification and two run of 10 Sqmm PVC insulated copper conductor(FRLSH) for earth continuity wire complete all as specified and directed by Engineer-in-Charge. Note : (i) Six run of cable with one run of PVC conduit/PVC casing and caping will be measured as one length.(ii) The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.
(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping of suitable size as per site requirement.
75
-
-
Surface excavation not exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in hard / dense soil complete all as specified and directed by Engineer in Charge.
145
-
-
M&L for 100mm thick Plain Cement Concrete 1:4:8 Type D-2 Nominal mix using 40mm crushed stone aggregate as in sub base floor including formwork complete all as specified and as directed by Engr in Charge.
170
-
-
M&L for 50mm thick Plain Cement Concrete (nominal mix) 1:2:4 type B1 using 20mm graded aggregate as in path/hard standing including formwork and provision of expansion joint laid in panels (2m) complete all as specified and as directed by Engineer-in-Charge.
170
-
-
Supply and laying of LT UG cable XLPE insulated armoured and PVC sheathed LT 1100 volts grade with aluminium conductor multi stranded of size 35sqmm 3.5core including suitable gland, crimping of lugs complete all as specified and directed
Note : Necessary earthwork shall be measured and paid separately.
75
-
-
Supply, laying of Telerex DWC (double Wall corrugated) HDPE pipe ISI marked of outer dia of 63 mm and inner dia 50 mm polethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as specified.
70
-
-
S&F MCCB DB VTPN 4 way IP-54 IK-09 made of sheet steel phos phatised, powder painted with bus bar 250amps, neutral link, earth bar and Din rail ,415 Volts with double door with MCCB incomer and MCB outgoing and fixing of cable with suitable size of lugs complete all as specified and as directed by Engr-in-Charge.
Note : MCCB and MCB will measured and paid separately
1
-
-
M&L for MCCB 63 Amps, thermal adjustable, current carrying capacity 16 KA , AC 415 Volts 4 pole complete all as specified and directed.
1
-
-
Supply and fix MCB triple pole 240 volts, 'C' curve of rating 25amps, with rupturing capacity 10 KA complete all as specified and as directed by Engr-in-Charge.
4
-
-
Excavation in trenches any type of soil (soft/loose) not exc 1.5m wide and not exc 1.5m in depth for foundation, pipe, laying of cable etc not exc 10 Sqm on plan and not exc 1.5m in depth and getting out complete all as specified and as directed by Engineer-in-Charge.
18.9
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements