To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date9 Jul 2022
Closing Date13 Aug 2022
Tender Amount₹ 70,74,820 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M & L for cutting out existing cracks in concrete surfaces / masonry wall / RCC Slab, forming Groove of 25mmx40mm size, cleaning the groove thoroughly with air blower, priming the groove with mixture of Resin & Hardener in 2:1 Proportions using Spray Gun to form a film on the surface of groove, filling the groove with putty made Resin, Hardener & River Sand, mixed in 1:1:4 ratio, and finally applying a Seal Coat of same as of Primer Coat with Spray Gun complete all as per Manufacturer's Instructions and Data Sheet, all as specified and as directed. Make of Construction Chemicals: M/s. Fosroc Chemicals India [P] Ltd. / M/s. Sika India Pvt. Ltd. / M/s. Choksey Chemicals Pvt. Ltd. / M/s. STP Ltd. / M/s. Bostik India Pvt. Ltd. / M/s. Thermax Ltd. / M/s. Hindcon Chemical Ltd. / M/s. Asian Paints Limited

150

-

-

... More
M & L for Cleaning the existing exposed reinforcement of Slab, Beam, Column, Footing etc. and any other RCC Structural members by emery paper, wire brush and finally with dry cloth, providing two coats of Polymer based Rust Remover as per manufacturer's instructions and allowed to react for 16 to 24 hours and finally cleaned with wire brush and washed thoroughly with clean water and finally applying One coat of Corrosion Inhibitor as per manufacturer's instructions on entire repair area to protect reinforcement embedded inside the concrete and reinforcement exposed and damaged complete all as specified and as directed. Note: The work shall be executed as per manufacturer’s data sheet and instructions after complete rust removal and also after provision of new / additional reinforcement. Make of Polymer based Rust Remover & Corrosion Inhibitor: M/s. Fosroc Chemicals India [P] Ltd. / M/s. Sika India Pvt. Ltd. / M/s. Choksey Chemicals Pvt. Ltd. / M/s. STP Ltd. / M/s. Bostik India Pvt. Ltd. / M/s. Thermax Ltd. / M/s. Hindcon Chemical Ltd. / M/s. Asian Paints Limited

85

-

-

... More
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.

300

-

-

... More
M & L for Drilling 15mm dia holes in to RCC Slab / Walls / Columns / Beams to a depth of 100 to 150mm, removing dust, etc. by vacuum cleaner and blowers and providing Shear Connector of 12mm dia rod of length of 175mm bent to "L" Shape with 75mm to be embedded in hole & 100mm to be used as dowel, fixed with Polyester Resin Grout mixed mechanically and poured in to the hole and Shear Connector shall be inserted and the top surface finished, allow the same to set complete all as per Manufacturer's Instructions and Data Sheet, all as specified and as directed. Make of Polyester Resin Grout: M/s. Fosroc Chemicals India [P] Ltd. / M/s. Sika India Pvt. Ltd. / M/s. Choksey Chemicals Pvt. Ltd. / M/s. STP Ltd. / M/s. Bostik India Pvt. Ltd. / M/s. Thermax Ltd. / M/s. Hindcon Chemical Ltd. / M/s. Asian Paints Limited

150

-

-

... More
S & F Hard drawn Welded Steel Wire Fabric / Expanded Metal of weight not exceeding 3 KG / Sq.m, cut to length, bent to shape required and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded to the existing reinforcement bars complete all as specified and as directed.

605

-

-

... More
M & L for applying a coat of Water based Acrylic Concrete Bonding Agent on the Concrete / Masonry / Plastered surfaces at the rate of 4 to 5 Sq.m / Litre to bind the old and new Guniting / Plastering complete all as per Manufacturer's Instructions and Data Sheet, all as specified and as directed. Make of Water based Acrylic Concrete Bonding Agent: M/s. Fosroc Chemicals India [P] Ltd. / M/s. Sika India Pvt. Ltd. / M/s. Choksey Chemicals Pvt. Ltd. / M/s. STP Ltd. / M/s. Bostik India Pvt. Ltd. / M/s. Thermax Ltd. / M/s. Hindcon Chemical Ltd. / M/s. Asian Paints Limited

275

-

-

... More
M & L for preparing the surfaces of concrete / masonry to receive Guniting / Plastering and providing pressure Guniting averaging 40mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 duly modifying the mortar with and including suitable Admixture / Bonding Agent @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., and finishing the top surface rough conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion complete all as per Manufacturer's Instructions and Data Sheet, all as specified and as directed. Make of Bonding Agent / Admixture: M/s. Fosroc Chemicals India [P] Ltd. / M/s. Sika India Pvt. Ltd. / M/s. Choksey Chemicals Pvt. Ltd. / M/s. STP Ltd. / M/s. Bostik India Pvt. Ltd. / M/s. Thermax Ltd. / M/s. Hindcon Chemical Ltd. / M/s. Asian Paints Limited

275

-

-

... More
M & L for spraying Curing Compound manufactured by M/s. Fosroc Chemicals India [P] Ltd. / M/s. Sika India Pvt. Ltd. / M/s. Choksey Chemicals Pvt. Ltd. / M/s. STP Ltd. / M/s. Bostik India Pvt. Ltd. / M/s. Thermax Ltd. / M/s. Hindcon Chemical Ltd. / M/s. Asian Paints Limited on freshly cast Guniting / Plastered surfaces complete all as per Manufacturer's Instructions and Data Sheet, all as specified and as directed.

275

-

-

... More
M & L for applying / rendering with High Build Polymer Modified Cement Mortar 1:3 mixed with 7 Litres of Polymer Modifier per bag of Cement in Ceiling / Wall surfaces of Concrete / Masonry / Gunited to an average thickness of 20mm thick in two layers, surfaces finished even and smooth without using extra cement complete all as per Manufacturer's Instructions and Data Sheet, all as specified and as directed. Make of Polymer Modifier & Bonding Agent: M/s. Fosroc Chemicals India [P] Ltd. / M/s. Sika India Pvt. Ltd. / M/s. Choksey Chemicals Pvt. Ltd. / M/s. STP Ltd. / M/s. Bostik India Pvt. Ltd. / M/s. Thermax Ltd. / M/s. Hindcon Chemical Ltd. / M/s. Asian Paints Limited

275

-

-

... More
M & L for applying Two Coats of High Performance Elastomeric Cementitious Water Proofing Coating to form minimum 1 mm thick over old or new concrete / masonry / plastered surfaces using the components at the ratio complete all as per Manufacturer's Instructions and Data Sheet, all as specified and as directed. Note: The waterproofing system shall be Non-Toxic Cementitious Waterproofing Coating and shall have Multiple Corrosion Inhibiting Synergies producing High Performance Elastomeric, Non Volatile, Low Temperature Flexibility and shall comply with ASTM D4060, ASTM D4541, ASTM D638, ASTM C836. Make of High Performance Elastomeric Cementitious Water Proofing Coating: M/s. Fosroc Chemicals India [P] Ltd. / M/s. Sika India Pvt. Ltd. / M/s. Choksey Chemicals Pvt. Ltd. / M/s. STP Ltd. / M/s. Bostik India Pvt. Ltd. / M/s. Thermax Ltd. / M/s. Hindcon Chemical Ltd. / M/s. Asian Paints Limited

275

-

-

... More
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces etc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.

210

-

-

... More
M & L for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of Wall / Ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed.

252

-

-

... More
Supply only integral water proofing compound [ISI marked] of approved make.

30

-

-

... More
M & L for preparing newly plastered Wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on Wall / Ceiling surfaces complete all as specified and as directed.

750

-

-

... More
S & F Rolled Mild Steel work conforming to Fe 410-W, Grade-E- 250, Quality-A as in Stairs [Framed] including Stringers, Treads, Landing, Balusters, Hand Rails etc. including cleats, brackets, etc complete all as specified and as directed.

440

-

-

... More
M & L for two coats of Synthetic Enamel paint over one coat of Red Oxide / Zinc Chrome Primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.

55

-

-

... More
Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris to a distance not exceeding 1.50 KM complete all as specified and as directed.

210

-

-

... More
M & L for Glazed Polish finished coloured Chequered Cement Concrete Tiles of thickness 23 to 25mm, made with M-25 Grade Precast Cement Concrete, Hydraulically pressed of size not less than 300 X 300 mm, of approved shape, colour and pattern, set, jointed and pointed in neat cement slurry to match including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed.

210

-

-

... More
Note for Serial Item No. 01 to 21: The rate quoted for various items is deemed to be inclusive of: [a] The work shall be carried out up to 15 Metres height of Overhead Water Tank and the rates quoted are deemed to be including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed. Contractor shall also provide suitable safety precautions and exhaust provisions as per manufacturer's instructions for using the various construction chemicals in congested and closed working conditions such as inside the Overhead Water Tank etc. Nothing shall be paid extra on this account. [b] Cleaning of Overhead Water Tank of One Lakh Gallon Capacity at any height by removing the inlet and outlet coupling connections, emptying all dirty / muddy water from the tanks using Diesel / Electric Driven Non-Clogging Pumps, removing the Scale / Sludge / Mud / Algae / Vegetation formed including other foreign materials got deposited on sides of walls and bottom of the tanks [Internal and External Surfaces] by scrapping and brushing with wire brush, Cutting / Chipping the spalling concrete surfaces and trimming to receive the epoxy treatment, cleaning with pressure pump, washing with bleaching powder slurry and allowing to dry and then washing, cleaning with acid based material, corrosion inhibitors and dispersing agents and finally cleaning the tank with fresh water, replacement of unserviceable / defective inlet and outlet coupling and fittings etc. complete after completion of all the structural repairs and disposal and depositing the demolished material out of MD land complete all as specified and as directed.

-

-

-

... More
[c] The rate quoted for respective items shall be deemed to be inclusive of all material, labour, expert supervision, Tools, Plant, Safety measures like safety belts, ropes, helmets, netting etc. required to work at any height as per site requirement complete all as specified and as directed. [d] 06 Nos. of Photographs of Overhead Water Tanks before and after Cleaning & Structural Repairs shall be submitted to GE for record before claiming payment. [e] Sample testing Overhead Water Tank before and after Cleaning & Structural Repairs from NABL Accredited Laboratory for Microbial parameters of water shall be submitted to GE for record before claiming payment. [f] The work shall be executed directly by the Manufacturer of the Chemicals or under the supervision and guidance of Manufacturer of the Chemicals by their Authorised Applicator. A certificate from Authorised Applicator and Manufacturer of the Chemicals shall be obtained by the contractor to the effect that work of structural rehabilitation has been carried out under their strict supervision and the same shall be submitted by the contractor to GE. The contractor shall also obtain a written guarantee for the effectiveness of the Structural Repairs carried out to the Overhead Water Tank for a period of 10 [Ten] Years from the certified date of completion of entire work from the Manufacturer of the Chemicals and shall be submitted to GE for record before claiming payment. The manufacturer shall also certify that the Structural Repairs of the Overhead Water Tanks have been carried as per the standard engineering practices and also certify the strength and serviceability of the Overhead Water Tank.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.