Military Engineer Services Tender
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Military Engineer Services - MES Tender
Civil And Construction
Pipe Line Project
Eprocure
Opening Date16 May 2024
Closing Date4 Jun 2024
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_654373_1Bid Award Id
ViewTender No
8494ATender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(d) 150 users
6
-
-
(e) 100 users
4
-
-
(f) 50 users
8
-
-
(g) 25 users
6
-
-
(h) 10 users
6
-
-
Removing carefully the cover slabs of man holes of any size and shape and removing the scum/ sludge including any organic or inorganic matters to a distance exc 50m and not exc 5000m and depositing where as directed by engineer in charge, and setting the man hole cover in position in CM (1:6) after cleaning the sludge for the following size of man holes (Manhole cover if provided new shall be measured & paid seperately) :- (a) Upto 1.5 mtr depth
1500
-
-
(b) Exc 1.5 mtr depth but n.exc 3.00 meter depth
600
-
-
Cleaning of blocked sewage drain pipe till the flow of sewage/sludge water is smooth including taking out all sludge/mud from pipes by means of roding & remove to a distance exc 50m and not exc 5000m and depositing where as directed by engineer in charge for following size of pipes :- (a) Internal dia 75 mm
100
-
-
(b) Internal dia 100mm
360
-
-
(c )Internal dia 150mm
3000
-
-
(d) Internal dia 200 mm
50
-
-
Cleaning and removing of blockage from WC upto first manhole removing all silt, liquid mud from the pipe line by roding etc and depositing the same at a distance exc 50m and not exc 5000 mtrs where as directed for following:- (a)In Ground Floor
250
-
-
(b) In First Floor
200
-
-
(C )In Second Floor
100
-
-
Cleaning and removing of blockage from floor trap at any location upto first manhole removing all silt, liquid mud or any othe foreign materials by roding and removing the same at a distance exc 50m and not exc 5000 mtrs and depositing where as directed by engineer in charge for following:- (a) In Ground Floor
240
-
-
(b) In First Floor
175
-
-
(c )In Second Floor
140
-
-
Taking out carefully the cover slab of gulley traps of any size and shape, depth and cleaning of blocked Gully traps including taking out all sludge/mud by means of roding,remove to a distance exc 50m and not exc 5000 mtrs and depositing where as directed by engineer in charge
240
-
-
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in soft/loose all as specified and as directed.
70
-
-
As per item No. 7 above but depth exceeding 1.5 metre and n.exc 3m all as specified and as directed.
6
-
-
Dismantling of cast iron pipe of internal dia 150 mm jointed in CM and taking out of trenches etc complete all as specified.
70
-
-
Dismantling of cast iron pipe of internal dia 100 mm jointed in CM and taking out of trenches etc complete all as specified.
30
-
-
Dismantling of cast iron pipe of internal dia 100 mm jointed in CM fixed to wall and taking out from wall etc complete all as specified.
25
-
-
Dismantling of cast iron pipe of internal dia 75 mm jointed in CM fixed to wall and taking out from wall etc complete all as specified.
30
-
-
M&L for PCC (1:3:6) type C2 using 40mm graded stone aggregate as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 100mm bore of pipes all as specified and as directed.
30
-
-
All as per item No 14 above but 150mm bore pipes
70
-
-
M&L for 150mm bore sand cast iron pipe, in any length with or without ears, with cement joints, laid in trenches or in floors including testing of pipe etc complete all as specified and directed
20
-
-
All as per item No. 15 above but 100mm bore of pipe all as specified and as directed.
13
-
-
M&L for 100mm bore sand cast iron pipe, in any length with or without ears, with cement joints, fixed to walls including testing of pipe etc complete all as specified and directed
25
-
-
All as per item No. 17 above but 75mm bore of pipe all as specified and as directed.
10
-
-
S&F in repair CI bend (any radius) bore of pipe 100mm with oval access door all as specified and directed.
6
-
-
S&F in repairs CI bend with duck's foot or heel rest bore of pipe 75mm with oval access door all as specified and directed.
5
-
-
S&F in repairs 100mm bore CI pipe single/Tee, branch pieces(Equal or unequal) ordinary or inverted(spigot or socket type) or with parallel branches and jointed complete all as specified and directed.
5
-
-
All as per item No 21 above but 75mm bore of pipe all as specified and directed.
3
-
-
S&F in repair 100mm bore CI pipe double branch pieces single 'Y' (Equal or unequal) ordinary or inverted(spigot or socket type) or with parallel branches and jointed complete all as specified and directed.
2
-
-
S&F in repairs CI Cowls 100mm bore of pipe all as specified and directed.
3
-
-
S&Fin repairs CI Cowls 75mm bore of pipe all as specified and directed.
3
-
-
Demolition of Solid block masonry set in CM as in man hole chamber and septic tank etc as in walling all as specified and directed
15
-
-
M&L for precast cement concrete block masonry with PCC 1:3:6,type C1, with solid blocks exc 10cm in width and set in CM (1:4) all as specified and directed.
23
-
-
Taking down cement plaster of any description from wall including raking out joints hacking for key, scrubbing down with water etc, complete all as specified and directed.
115
-
-
M&L for rendering 15mm thick in CM (1:3) on concrete/brick / solid block masonry surfaces as in manhole, septic tank etc finished even and smooth without using extra cement all as specified and directed.
60
-
-
M&L for rendering 15mm thick in CM (1:6) on concrete/brick/Solid block masnory wall surfaces finished even and fair all as specified and directed.
55
-
-
M& L for Finishing walls with Acrylic smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) etc complete all as specified and as directed by Engineer-in-Charge.(Make Apex Ultima)
55
-
-
Demolition of cement concrete reinforced of any description and in any position complete all as specified and as directed.
7
-
-
M&L for providing precast RCC (1:2:4) type B1 using 20mm graded stone aggregate as in cover slab for manholes, septic tank and similar work set in CM (1:6) all as specified incl necessary form work and placed in position all as directed
7
-
-
M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking and bending spirally for hopping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia) or securing with clips complete.
550
-
-
Returning, filling in, incl spreading, levelling, watering and well ramming in layers n.exc 25cm thick with soils all as specified and directed.
40
-
-
Removing excavated soils to a distance n.exc 50M and depositing where directed at a level n.exc 1.5M above the starting point all as specified and directed.
15
-
-
M&L for CI gully traps in repairs square or round mouthed of size 150 x 150 mm, type 'P' incl making good the disturbed surfaces like plinth protection all as specified and directed.
10
-
-
Cutting of small trees/plants at the stem removal of the roots of the plants by using acids, cutting around the spout for removing the roots of any size and making good with CM (1:3) incl two coats of cement base paint complete all as directed by Engineer-in-Charge
100
-
-
S & F in repairs PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints fixed to walls complete all as specified and as directed
150
-
-
All as per item No.39 above but 75mm bore
50
-
-
S & F in repairs PVC (SWR) pipes 150 mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed
30
-
-
S & F in repairs PVC (SWR) bend of any radius with oval access door, 110mm bore all as specified and as directed
15
-
-
All as per item No.42 above but 75mm bore
15
-
-
S & F in repairs 110mm bore PVC (SWR) junction, (Single 'T') equal or unequal all as specified and as directed
15
-
-
All as per item no.44 above but 75mm bore
10
-
-
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc. 15cm thickness etc below or above ground level incl floor hearth tiles if any and removing the rubbish off the premises complete all as specified and as directed by Engr-In -Charge.
22
-
-
M&L plain cement concrete (1:4:8) type D2 using 40mm graded stone aggregate as in foundation.
3
-
-
M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregates as in benching, haunching and channel etc finished even and smooth using extra cement including necessary form work.
2
-
-
M&L for PCC 1:3:6 type C1 using 20mm graded stone aggregate as in coping etc , rounded or chamfered on edges all as directed
1.5
-
-
M&L for Plain cement concrete 1:3:6, type C2, using 40 mm graded stone aggregate, as in surface channels/drains etc, complete all as specified
1.5
-
-
M&L for PCC (1:3:6) type C2 using 40mm graded stone aggregate as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200mm bore of pipes all as specified and as directed.
12
-
-
S&F in repairs mild steel chromium plated gratings fixed in cement mortar or coloured cement mortar to match with the existing surfaces complete all as specified.
50
-
-
M&L for rendering 10 mm thick in CM 1:4 on concrete or block masonry surfaces finished even and smooth without using extra cement complete all as specified.
25
-
-
M&L for PCC 1:5:10, type E2, using 40 mm graded stone aggregate as in filling of sunken portion of slab etc complete
17
-
-
M&L for PCC 1:2:4, type B1, 40 mm thick, using 20 mm graded aggregate as in floor for laying floor finishes complete all as specified.
100
-
-
M&L for cast iron floor trap 100 mm outlet dia with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4)
5
-
-
M&L for PVC (SWR) floor trap 100 mm outlet dia with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4)
12
-
-
M&L for cast iron Nahani trap 100 mm outlet dia with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4)
5
-
-
M&L for PVC (SWR) multi floor trap 100 mm outlet dia with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4)
5
-
-
M&L for PVC (SWR) floor trap, 75 mm outlet dia plain with grating including jointing with solvent cement
10
-
-
M&L for PCC 1:4:8, type D2, 75 mm thick as in sub base of floor, plinth protection pavings etc
42
-
-
Material & labour for designer coloured chequred cement concrete tiles of size 30 cm x 30 cm x 25 mm with jointed and pointed in neat cement slurry with grey pigment cement and pigment to match the shade including screed bed 20mm in CM (1:4) all as specified and directed.
100
-
-
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing the rubbish off the premises.
146
-
-
M/L 25mm thk PCC 1:2:4 type B-0 using 12.5 mm graded agg as in flooring finished fair and even without using extra cement.
46
-
-
M&L for coloured non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.06 sqm n.exc 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed with coloured cement to match the colour of tiles over and including screed bed or bedding layer of mortar 10mm thick in CM 1:4 for laying floor finishes complete all as specified and directed.
46
-
-
M&L for coloured glazed ceramic tiles, 350x 250x 7mm/ 450X 350X 7mm thick on vertical surfaces set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tile over and including rendering 10mm thick in CM 1:3 complete all as specified and as directed by Engineer-in-Charge.
100
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements