Military Engineer Services Tender

To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date19 Nov 2024
Closing Date3 Dec 2024
Tender Amount₹ 40,50,000 
Notes
Download

Costs

Summary

Certain Repair And Maint Of Internal Electrification System Including Day To Day Maint Of Fittings, Fixtures Of Certain Otm Accn At Srinagar Colony And Periodical Services To Certain Otm And Md Accn Of Nts, Marcos, Chouldari, Dad Qtrs, Prothrapur, Pe

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for point wiring with two run of PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm (FRLSH), PVC conduit medium grade/ PVC casing caping and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing one run of 1.5 sqmm PVC insulated unsheathed multistranded copper conductor cable (FRLSH) as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and as directed by Engineer in Charge. (In ceiling Portion surface conduit wiring shall be carried out.) Note: The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.(c) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment

-

-

-

... More
One light point controlled by one one way switch.

120

-

-

... More
One 3 pin socket outlet 5/6 Amps on independent board

70

-

-

... More
One 3 pin socket outlet 5 Amps on the same board with other switches

50

-

-

... More
One light point controlled by two 2-way switches.

10

-

-

... More
One bell/ buzzer point controlled by one push button

8

-

-

... More
All as per item No 4 above but cable with 2.5 sqmm size for socket outlet 15 amps on independent board complete all as specified and directed by Engineer-in-Charge.

48

-

-

... More
M&L for point wiring with two run of PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm (FRLSH), PVC conduit medium grade/ PVC casing caping and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc) and drawing one run of 1.5 sqmm PVC insulated unsheathed multistranded copper conductor cable (FRLSH) as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and as directed by Engineer in Charge. (In ceiling Portion surface conduit wiring shall be carried out.) Note: The quoted rate inclusive for the following :- (a) GI metal flush box and Modular cover plate with frame of any module complete. (b) Proper colour coding is to be followed as per IS Specification. (c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.(d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment

-

-

-

... More
One light point controlled by one one way switch.

36

-

-

... More
One 3 pin socket outlet 5/6 Amps independent.

21

-

-

... More
One 3 pin socket outlet 5 Amps on the same board with other switches

15

-

-

... More
One light point controlled by two 2-way switches.

3

-

-

... More
One bell/ buzzer point controlled by one push button

4

-

-

... More
All as per item No 6 above but cable with 4.0 sqmm size for socket outlet 15 amps on independent board complete all as specified and directed by Engineer-in-Charge

16

-

-

... More
M & L for submain wiring with four single core PVC insulated unsheathed multistranded copper conductor cable of size 10 sqmm (FRLSH) and one single core PVC insulated unsheathed multistranded copper conductor cable green colour of size 10 Sqmm (FRLSH) as earth lead in and including concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing caping of suitable size and making good the disturbed wall surfaces to match with existing specification including takind down unserviceable submain wiring complete all as specified and as directed by Engineer in Charge. Note : (i) Five run of cable with one run of PVC conduit/PVC casing and caping will be measured as one unit length. (ii) Wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.

60

-

-

... More
M & L for submain wiring with two single core PVC insulated unsheathed multistranded copper conductor cable of size 6 sqmm (FRLSH) and one single core PVC insulated unsheathed multistranded copper conductor cable green colour of size 6 Sqmm (FRLSH) as earth lead in and including concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing caping of suitable size and making good the disturbed wall surfaces to match with existing specification including takind down unserviceable submain wiring complete all as specified and as directed by Engineer in Charge. Note : (i) Three run of cable with one run of PVC conduit/PVC casing and caping will be measured as one unit length. (ii) Wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.

240

-

-

... More
All as per item No. 9 here-in-before but with 4.0 sqmm cable complete all as specified and as directed by Engineer in Charge.

180

-

-

... More
All as per item No. 9 here-in-before but with 2.5 sqmm cable complete all as specified and as directed by Engineer in Charge.

150

-

-

... More
All as per item No. 9 here-in-before but with 1.5 sqmm cable complete all as specified and as directed by Engineer in Charge.

110

-

-

... More
S&F switch piano, flush type, single pole, one way 6 Amp complete all as specified and as directed by Engineer in Charge

120

-

-

... More
S&F bell push, flush type 5/6 amps complete all as specified and directed by Engineer in Charge.

8

-

-

... More
S&F switch piano, flush type, single pole, two way 6 Amp complete all as specified and as directed by Engineer in Charge

20

-

-

... More
S&F switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type complete all as specified and as directed by Engineer in Charge

48

-

-

... More
S&F switch socket combination 2 in 1, 6 Amp flush type complete all as specified and as directed by Engineer in Charge

120

-

-

... More
S&F ceiling Rose, 3 terminal polycarbonate isolated body complete all as specified and as directed by Engineer in Charge.

168

-

-

... More
S&F modular switch one way 6 Amps, 1 module complete all as specified and as directed by Engineer in Charge

72

-

-

... More
S&F modular switch two way 6 Amps, 1 module complete all as specified and as directed by Engineer in Charge

6

-

-

... More
S&F modular switch one way 16 Amps, 1 module complete all as specified and as directed by Engineer in Charge.

16

-

-

... More
S&F modular bell push 6 Amps, 1 module complete all as specified and as directed by Engineer in Charge.

4

-

-

... More
S&F modular socket, 2/3 pin 6 amps, 2 module complete all as specified and as directed by Engineer in Charge.

36

-

-

... More
S&F modular socket, 2/3 pin 6/16 amps, 2 module complete all as specified and as directed by Engineer in Charge.

16

-

-

... More
S&F as in repair LED lights tube light fitting 20W, 100lm/watt, CCT value 6500K, surge protection of 2 KV, 4 feet 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer in Charge.

520

-

-

... More
S&F as in repair LED 20W inverter batten type fitting 3 or 4 feet long aluminium extruded housing, charging time 10-12 Hrs with 04 Hrs backup,IP-20 ,rated voltage 230 V, 50 Hz, system wattage 20W +/- 10%, system current less than 102 mA, power factor more than 0.95, system lumen efficiency 100lm/watt,CCT 6500K, CRI more than 80, THD less than 30%, driver efficiency more than 85% complete all accessories prewired and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer in Charge.

110

-

-

... More
S&F as in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt, 120lm/watt, CCT value 6500K, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer in Charge.

170

-

-

... More
Supply & fixing in repair LED luminaire 600mm X 600mm, 36 watt, 220V AC, 3600 lm, 6500K, recessed type with high efficiency PMMA diffuser soft glare free light complere with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by Engineer in Charge.

12

-

-

... More
S&F as in repair round LED surface downlighter 15 watt, 220V, 1200lm, CCT value 6500K complete all as specified and as directed by Engineer in Charge.

10

-

-

... More
S&F as in repair indoor LED wall light 6W, 210lm, CCT value 3000K complete all as specified and as directed by Engineer in Charge.

8

-

-

... More
Supply and fixing in repair LED bldg security light fitting 25 watt not less than 2500lm, 230V AC outdoor type, pressure die cast housing with epoxy powder coated, dark graphite grey colour finish, poly carbonate cover with individual LED lenses with IP 65 protection with 10 KV SPD including complete all specified and as directed by Engineer in Charge. Note for item No 25 to 31 : (i) Driver efficiency should be more than 85% (Constant current driver) (ii) Non isolated type driver (iii) THD less than 20% (iv) LED driver current less than 60 mA (v) Efficiency of LED Chip more than 130 lm/watt (vi) Efficiency of LED Fixture not less than 100 lm/watt (vii) Surge protection 2.0 KV & above as per IEC standard (viii) working humidity 95%RH (ix) Life 50000 Hrs at 70% lumes (x) CRI more than 80 (xi) Working temp -10 degree to 50 degree C (xii) Heat Sink extruded aluminum (xiii) junction temperature 85 degree C (xiv) Body of fitting Extruded Aluminum (xv) impact code Min IK 03 or more ( xvi) LM79 report from thir party (instead of company in house lab) NABL/UL accredited lab (xvii) LM 80 report from LED manufacturer (xviii) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixture (xviiii) IP-20 .(xx) Test certificates to be submitted before commencement of work/ claiming for payment .(xxi) Warranty certificate for minimum 2 years to be submitted from OEM.

30

-

-

... More
S&F as in repair LED bulb 9 watt, B22 complete all as specified and as directed by Engineer in Charge

460

-

-

... More
S&F as in repair lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed by Engineer in Charge.

110

-

-

... More
S&F as in repair Bell, Ding Dong AC, 230 Volts omplete all as specified and as directed by Engineer in Charge

120

-

-

... More
Supply & fixing ceiling fan 1200mm sweep with blades, suitable BLDC remote electronic regulator as per OEM design, down rods and connected accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM, 5 star rated, equipped with brushless direct current motor (BLDC) of wattage 28W including provision of cable from ceiling rose/connector to fan including taking down old unserviceable ceiling fan and deposited to MES store yard complete all as specified and as directed by Engineer in Charge.

60

-

-

... More
S&F metallic exhaust fan of size 300 mm with louver, 230V, RPM 1400, metal body including taking down old unserviceable exhaust fan and deposited to MES store yard complete all as specified and as directed by Engineer in Charge.

20

-

-

... More
S&F exhaust fan louver aluminium suitable for hole of size 300mm fixing up to 3rd floor complete all as specified and as directed by Engineer in Charge. Note : Necessary scaffolding for fixing of louver shall be deemed to be included in the quoted rate.

50

-

-

... More
Supply and fixing as in repair MCCB DB VTPN 4 way IP-54, IK-09 made of sheet steel phos phatised, powder painted with bus bar 250A, neutral link, earth bar and Din rail 415 Volts with double door, suitable for MCCB 4 Pole 100 Amps as incomer and MCB Single Pole as outgoing complete all as specified and as directed by Engineer in Charge.

6

-

-

... More
Supply & fixing as in repair sheet metal enclosure with TPN MCB DB's 4 way (grouted in walls) double door type IP-54, IK-09 Protection. Isolated Neutral,Door earthing, cement spill protector complete including cutting chases to wall for fixing DB and making good the disturbed wall surface complete all as specified and as directed by Engineer in Charge.

3

-

-

... More
Supply & fixing as in repair MCB DB's SPN 8 way, IP-54, IK-09 double door, sheet metal enclosure, 240V, 100 amps rated busbar including suitable size of copper ferrules for fixing of cable complete all as specified and as directed by Engineer in Charge. Note for item srl No 38 to 40: (i) MCCB and MCB will be measured and paid separately. (ii) The cost for flushing of Distribution box in any type of wall and making good disturbed surfaces with existing colour and finish shall be deemed to be included in the quoted rate

18

-

-

... More
Supply and fixing in repair Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and as directed by Engineer in Charge.

10

-

-

... More
S&F as in repair MCCB 4 Pole, 415V, Adjustable type, 100 to 125 Amps with breaking capacity 16 KA complete all as specified and as directed by Engineer in Charge.

6

-

-

... More
S&F as in repair MCB TPN 40 to 63 Amp, C series, 415V, 10 KA complete all as specified and as directed by Engineer in Charge.

3

-

-

... More
S&F as in repair MCB SPN 40 to 63 Amps ,10 KA, C Curve, 230 Volt, 50 HZ complete all as specified and as directed by Engineer in Charge.

80

-

-

... More
S&F as in repair MCB SP 6-32 Amps ,10 KA, C Curve, 230 Volts ,50 HZ complete all as specified and as directed by Engineer in Charge.

130

-

-

... More
S&F as in repair Surge Protection Device, breaking capacity 40KA/Pole, 4 Pole with sheet metal enclosure complete all as specified and as directed by Engineer in Charge.

20

-

-

... More
M&L for carrying out internal wiring test with all T&P such as megger, clamp meter/multi meter etc., by opening of main DBs/TPN DBs/SPN DBs disconnecting of phase and neutral cable connection, fittings, fixtures carrying out testing for insulation values, reconnecting the disconnected cable connections, fittings and fixtures including replacement of defective copper ferrules, insulation peeled off wires with insulation tape complete all as specified and as directed by Engineer in Charge. Note : (i) The cost of copper ferrules and insulation tape shall be deemed to be included in the quoted rate. (i). The inspection shall be carried out in presence of JE E/M, I/C Elect(HS)/MCM detailed by JE E/M with user's signature. (ii) Each Qtr will be measured as one job.

280

-

-

... More
Repair, maint and making the continuity of supply after rectifying the defects of the electrical items such as switches, sockets, bell push, ceiling roses, metal/PVC flush boxes, modular cover plate with frame and other similar electrical items/fittings etc. including provisioning of small run of electrical wires if required of size 1.5 sqmm to 2.5 sqmm single core and length not exceding 0.50m complete all as specified and directed by Engineer in Charge. Note :- (i) Any accessories if found unserviceable shall be replaced and paid as "supply only" under respective items of this Sch 'A' . (ii) One unit job only will be considered for payment purpose irrespective of the No of points made serviceable in an qtr/bldg.(iii) The area for attending the complaints are Minnie Bay area (iii) Each complaint attended/rectified shall be measured as one unit job. (iv) The contractor shall depute necessary man power on daily basis for rectifying the jobs including sundays and holidays.

590

-

-

... More
Supply only switch piano, flush type, single pole, one way 6 Amp for carrying out repairs under relevant Sch 'A' item No. 48 complete all as specified and as directed by Engineer in Charge

410

-

-

... More
Supply only switch piano, flush type, single pole, two way 6 Amp for carrying out repairs under relevant Sch 'A' item No. 48 complete all as specified and as directed by Engineer in Charge

16

-

-

... More
Supply only bell push, flush type 5/6 amps for carrying out repairs under relevant Sch 'A' item No. 48 complete all as specified and as directed by Engineer in Charge

85

-

-

... More
Supply only switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type for carrying out repairs under relevant Sch 'A' item No. 48 complete all as specified and as directed by Engineer in Charge

130

-

-

... More
Supply only switch socket combination 2 in 1, 6 Amp flush type for carrying out repairs under relevant Sch 'A' item No. 48 complete all as specified and as directed by Engineer in Charge

260

-

-

... More
Supply only ceiling Rose, 3 terminal polycarbonate isolated body for carrying out repairs under relevant Sch 'A' item No. 48 complete all as specified and as directed by Engineer in Charge

70

-

-

... More
Supply only modular switch one way, 6 Amps, 1 module for carrying out repairs under relevant Sch 'A' item No. 48 complete all as specified and as directed by Engineer in Charge

10

-

-

... More
Supply only modular switch one way, 16 Amps, 1 module for carrying out repairs under relevant Sch 'A' item No. 48 complete all as specified and as directed by Engineer in Charge

4

-

-

... More
Supply only modular socket, 2/3 pin, 6 amps, 2 module for carrying out repairs under relevant Sch 'A' item No. 48 complete all as specified and as directed by Engineer in Charge

10

-

-

... More
Supply only modular socket, 2/3 pin, 6/16 amps, 2 module for carrying out repairs under relevant Sch 'A' item No. 48 complete all as specified and as directed by Engineer in Charge

4

-

-

... More
Supply only FRLSH PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm , cut to size all as required at site for carrying out repairs under relevant Sch 'A' item No. 48 complete all as specified and as directed by Engineer in Charge

150

-

-

... More
Supply only FRLSH PVC insulated unsheathed multistranded copper conductor cable of 2.5 sqmm , cut to size all as required for carrying out repairs under relevant Sch 'A' item No. 48 complete all as specified and as directed by Engineer in Charge

180

-

-

... More
Supply only FRLSH PVC insulated unsheathed multistranded copper conductor cable of 4.0 sqmm , cut to size all as required at site for carrying out repairs under relevant Sch 'A' item No. 48 complete all as specified and as directed by Engineer in Charge

110

-

-

... More
Supply only FRLSH PVC insulated unsheathed multistranded copper conductor cable of 6.0 sqmm , cut to size all as required at site for carrying out repairs under relevant Sch 'A' item No. 48 complete all as specified and as directed by Engineer in Charge

160

-

-

... More
Material and labour for earthing with galvanised earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 25 mm x 4 mm by means of GI Welding made out of galvanised iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead and connected to control board or transformer neutral earth or as directed by Engineer in Charge including earthing pit in PCC (1:3:6) type C-1, pre-cast reinforced cover with MS XPM Jalli, RCC 1:1.5:3 cover slab of size 300 x 300 x 100 mm with one handle made out of 8 mm dia round bar 20 mm dia GI pipe medium grade for watering funnels , wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete shown in electrical plated No 3 and testing complete all as specified and as directed by Engineer in Charge. NOTE : (i) The earthing pit should be provided with proper earth pit and pit cover. (ii) If the desired earth resistance is not achive during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissable.

4

-

-

... More
Taking down cement plaster on brick or concrete and racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed by Engineer in Charge.

120

-

-

... More
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed by Engineer in Charge.

100

-

-

... More
M&L rendering 5mm thick in CM (1:3) on ceiling surfaces finished even & smooth without using extra cement complete all as specified and as directed by Engineer in Charge.

20

-

-

... More
M&L for preparation of newly plastered ceiling surfaces and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed by Engineer in Charge.

20

-

-

... More
M&L preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed by Engineer in Charge.

100

-

-

... More
M & L for preparation of old wooden surfaces exc 10cm width and girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer in Charge.

200

-

-

... More
M & L for preparation of old steel surfaces exc 10cm width and girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer in Charge.

140

-

-

... More
M & L for preparation of old distempered surfaces of walls and applying one coat of oil bound distemper complete all as specified and as directed by Engineer in Charge. Make : Asian paints Tractor suprema

4300

-

-

... More
M & L for preparation of old distempered surfaces of ceiling and applying one coat of oil bound distemper complete all as specified and as directed by Engineer in Charge. Make : Asian paints Tractor suprema

800

-

-

... More
M & L for complete removal of existing treatment on wall & applying plaster of paris putty of 1mm thickness finishing the surface by appliying two coat of oil bound distemper along with primer over plastered surfaces complete all as specified and as directed by Engineer in Charge. Make : Asian paints tractor suprema

400

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.